| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 16-02-2026 | BOQ corrigendum | BOQ | 07-03-2026 |
| Sl. No. | Item Description |
| 1 | M&L for cement concrete1:4:8type D2,using 40mm graded crushed stone aggregate as in foundations filling and mass concrete complete all as specified and directed. |
| 2 | M&L for PCC 1:3:6 type C-1 (using 20mm graded crushed stone aggregate) as in copping and filling in back of chowkatthe like including weathering, slightly rounded or chamfered angles and throating complete all as specified and directed. |
| 3 | M&L forProviding, cement concrete1:2:4type-B1 using 20mm graded crushed stone aggregate in lintels upto 1.5m clear span, cills, steps;roof padding, seismic and other similar bands,plinth courses, string courses,lacing courses, parapets and railings upto 60 cm in height,copings, kneelers, apex stones,bed plates, kerbs not provided for in Item 04028, water troughs and the like including weathering, slightly rounded or chamfered angles and throating, as directed complete all as specified and directed. |
| 4 | Supply only integral water proofing compound liquid grade conforming to IS-2645 complete all as specified and directed. |
| 5 | M&L for brickwork with old size fly ash bricks, straight or curved on plan exc 6m mean radius, built in cement mortar 1:6 complete all as specified and directed. |
| 6 | M&L for brickwork with old size fly ash bricks, straight or curved on plan to any radius as in half brick thick walls, built in cement mortar 1:4 complete all as specified and directed. |
| 7 | M&L for Cutting holes into or through brick walls built in cement mortar or cement lime mortar and making good in cement mortar 1:3 or cement concrete 1:2:4 type B-l as required exc 150sqcm but not exc 400sqcm complete all as specified and directed. |
| 8 | Making good under cills or over arches, lintels and bressummers. including all pinning in cement mortar 1:4when necessary complete all as specified and directed. |
| 9 | M&L for IInd class hardwoodPlain, solid, straight chowkats and frames, wrought, framed rebated on the solid, rounded or chamfered,put together with glue pinned at joints, supplied and fixed complete all as specified and directed. |
| 10 | S&F 30mm thick factory made flush shutter, solid core construction with block board core and plywood face panels, commercial type on both sides kiln seasoned and chemically pressure treated complete all as specified and directed. |
| 11 | Taking down chowkat or frame with shutter (without taking off shutter from the frame) area not exc. 1.5sqm each, including cutting holes for removing the hold fast,making good disturbed surfaces and removing materials from site of work complete all as specified and directed. |
| 12 | Taking down chowkat or frame with shutter (without taking off shutter from the frame) exc. 1.5 sqm and n.exc 4 sqm each, including cutting holes for removing the hold fast, making good disturbed surfaces and removing materials from site of work complete all as specified and directed. |
| 13 | Taking down old unserviceable shutters of any description exc 1.00 but n.exe 2.00 Sqm each complete all as specified and directed. |
| 14 | S&F Factory Made Solid PVC Moulded Door Shutter with particle board core , 28 to 30mm thick (stiles), with 2, 4, or 6 raised panel design with 2mm thick Moulded PVC Sheet on the front face & 2mm plain colour PVC sheet on back face, supplying & fixing in frame at site as per specification & drawing complete all as specified and directed. |
| 15 | S&F Solid PVC frame (Single Rebated) of size 60mm x 30mm made out of solid PVC foam with homogenous fine cellular structure having smooth outer integral skin with suitable metal stiffner and fixed with 100 x 8 sheet metal CSK screws complete all as specified and as shown on drawing.(Note :- Door frame shall be water proof, termite proof, elegant andshould have excellent screws holding strength to fix hinges and hold doors properly for a long life)complete all as specified and directed. |
| 16 | S&F 150mm aluminium anodised barrel tower bolts of extruded sectioncomplete all as specified and directed. |
| 17 | S&F 300 mm long aluminium alloy, anodised,sliding door bolt with hasp,staple (bolt type) andfixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed complete all as specified and direcetd. |
| 18 | S&F 100mm Butt hinges,medium weight, cold rolled mild steel,complete all as specified and directed. |
| 19 | S&F 150mm size aluminium handle cast typecomplete all as specified and directed. |
| 20 | S&F in repairs stainless steel decorative curtain rod of 20 mm bore with wood finishes, complete all as specified and as directed. |
| 21 | S&F in repairtubular towel rail 20mm dia type brass chrormium plated 600mm long between flanges complete all as specified and directed. |
| 22 | M&L in repairGalvanised mild steel wire cloth, 0.63mm nominal dia of wire and average width of aperture 1.40mm and fixed with tinned tacks, or galvanised wire staplescomplete all as specified and directed. |
| 23 | S&F Stainless steel wire cloth. 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staplescomplete all as secified and as directed |
| 24 | M&L for MS framed work such as grills,gratings, etc.. with ends of bars shouldered and/or riveted,or forged into spikes; framed guard bars; barred iron doors;ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165complete all as specified and directed. |
| 25 | S&F roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc conforming to Fe -410-W(Gde-E-250) quality-A. complete all as specified and directed. |
| 26 | S&F steel window with side hunge shutters including projecting type hinges with steel handle and steel peg stey, tower bolts etc. complete with glazing bars dovetailed or weldedcomplete all as specified and directed. |
| 27 | S&F steel window with side hunge shutters including projecting type hinges with steel handle and steel peg stey, tower bolts etc. complete without glazing bars dovetailed or weldedcomplete all as specified and directed. |
| 28 | S&F Steel ventilator with top hung shutter including hinges, steel peg stay, complete all as specified and directed. |
| 29 | M&L for 1.25mm thickpressed steel door frame of size 165mm x 60mm with one or more rebates including necessary , hinges, lock strike plate, fixing lugsetc complete as specified. |
| 30 | M&Lfor 1.25mm thickpressed steel door frame of size 105mm x 60mm with one or more rebates including necessaryfixing lugs , hinges, lock strike plate etc complete all as specified and directed. |
| 31 | M&L for anodised aluminium snap grid (SIZE-605x605MM) frame work for false ceiling complete all as specified and directed. |
| 32 | S&F Hangers 6 mm dia. G.I. (upto 1200mm length) adjusting level fixed to roof slabs by means of ceilling cleats made out of G.I. flat 40 x 3 mm size 60mm long and expansion hold fasteners 12.5mm dia. 40mm long complete all as specified and directed. |
| 33 | S&F Hard drawn steel wire fabric in available size Weight per square metre Not exc4 kg complete all as specified and directed. |
| 34 | S&F Pre- painted coloured trapezoidal profiled Galvalume/ Zincalume sheet with min thickness 0.50mm TCT confirming to IS - 513(AZ-150 GSM, Al Zn allay metalic coating with 550 Mpa yield stress as per AS-1397) as in roof covering/cladding towall, fixed with self tapping screws colour exterior coat of silicon modified polyster/BHP x RW paint system 20 micron top coat applied over 5 micron primer and 5 micron polyster back coat applied over 5 micron primer , all fixed with galvanized self drilling self tapping fastner (12-14 x 55 with EPDM seals) complete all as specified and directed. |
| 35 | S&F Pre- painted coloured plain sheet Galvalume/ Zincalume sheet with min thickness 0.50mm TCT confirming to IS - 513(AZ-150 GSM, Al Zn allay metalic coating with 550 Mpa yield stress as per AS-1397) as in roof covering/cladding towall, fixed with self tapping screws colour exterior coat of silicon modified polyster/BHP/ XRW paint system 20 micron top coat applied over 5 micron primer and 5 micron polyster back coat applied over 5 micron primer , all fixed with galvanized self drilling self tapping fastner (12-14 x 55 with EPDM seals) complete all as specified and directed. |
| 36 | S&F 4 mm thick designed Non asbestos fiber cement pre-painted building boards, fixed or laid /inserted totimber /GI /Aluminium frame-work with screws complete all as specified anddirected. |
| 37 | Dismantling of floor, hearth or wall tiling / Paving Blocks including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises etc complete all as specified and directed. |
| 38 | Taking down cement plaster on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water, etc. complete all as specified and directed. |
| 39 | M&L for sheet glass, 3mm thick, plain ordinary quality and glazing with oil putty in squares n exc. 0.50 Sqm each panecomplete all as specified and directed. |
| 40 | M&L for sheet glass, 4mm thick, ordinary quality and glazing with oil putty in squares n exc. 0.50 Sqm each panecomplete all as specified and directed. |
| 41 | M&Lfor preparation of untreated new wood/wooden surface of any description over 10cm width or girth and applying two coats of synthetic enamel paint (1st grade quality) over a coat of pink primer complete all as specified and directed. |
| 42 | M&L for preparing the back surfaces of chaukhats and treating them with tar or coal tar black paint complete all as specified and directed. |
| 43 | M&L for two coats of synthetic enamel paint over one coat of red oxideon new steel surfaces of any description over 10cm in width or girthincluding preparation of surfaces complete all as specified and directed. |
| 44 | Taking up or down steel tubing and connections,including cleaning for refixing or removal to store bore of pipe 15 mm complete all as specified and as directed |
| 45 | Taking up or down steel tubing and connections,including cleaning for refixing or removal to store bore of pipe 20 mm complete all as specified and as directed |
| 46 | Dismantling water tanks and removing to store exc 250 ltr but not exc 500 ltr capacity complete all as specified and as directed |
| 47 | S&F rotational moulded PVC water storage tank 500 ltrs capacity conforming to IS-12701(1989) cylindrical vertical type double-layered with closed top (thereated) including inlet,outlet and wash out holes of approved make hoisted and fixed in position all as specified in SSR Part I etc completge all as specified and directed. |
| 48 | S&F in repair fancy type with long shank and cup (concealed type) chromium plated stop valve cast copper allow screw down high pressure with crutch or butterfly handle screwed both end form iron pipe or for union and fixed of size 15mm dia complete all as specified and directed. |
| 49 | S&F in repairGun metal globe or gate valves with iron wheel head screwed both ends for iron pipe 20mm bore and fixed as in repair complete all as specified and directed. |
| 50 | S&F ball valves for 20mm bor dia of pipehigh pressure of PTMT with epoxy coated Aluminium rod & highdensity plastic ball screwed for iron pipe and fixed. (Minimum weight 15mm-142gms/ 2 0mm-210gms./25mm-455gms/ 40mm - 690 gms) complete all as specified and directed. |
| 51 | S&F in repair PVC connectionspipe ,15mm dia size with PTMT nuts of length 450mm complete all as specified and directed. |
| 52 | S&F in repair 75mm bore PVC, waste and vent pipes, in any length with or without ears with cement joints, laid in trenches or in floors or vertically cast, complete all as specified and directed. |
| 53 | S&F in repair 110mm PVC (SWR) as in drain pipes single socketed in any length with rubber ring jointslaid in trenches or in floors complete all as specified and directed. |
| 54 | S&F in repair 110mm PVC (SWR)pipes single socketed in any length with rubber ring joints fixed to wallscomplete all as specified and directed. |
| 55 | S&F 75mm bore PVC (SWR) bends with rubber ring joints any radius complete all as specified and directed. |
| 56 | S&F in repair 75mm bore PVC (SWR) bends with access door and rubber ring joints any radius complete all as specified and directed. |
| 57 | S&F110mm bore PVC (SWR) bends with rubber ring joints any radius complete all as specified and directed. |
| 58 | S&F75mm bore PVC (SWR) branch piece,single (single Y) equal or unequal complete all as specified and directed. |
| 59 | S&F110mm bore PVC (SWR) branch piece,single (single Y) equal or unequal complete all as specified and directed. |
| 60 | S&F in repair PVC (SWR) floor trap 75mm dia , plain with grating including jointing to waste pipe in cement concrete 1:2:4 type B1 using 20mm graded crushed stone aggregate complete all as specified and directed. |
| 61 | S&F in repairs PVC (SWR) gully trap 125/110 mm, setting and jointing with solvent cement etc complete all as specified and directed. |
| 62 | S&F in repair 600mmx450mm bevelled edge mirror of selected quality glass, mounted on 6mm thick AC building board or commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers complete all as specified and directed. |
| 63 | Demolition of Brickwork or stone/boulder masonry, built in cement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings,dressed stonework and precast concrete articles complete all as specified and directed. |
| 64 | Demolition of cement concrete( un-reinforced)in ground floorand paving n.exc 15 cm thickness( below or above ground level) complete all as specified and directed. |
| 65 | Demolition of Concrete un- reinforced of any description and in any position not otherwise specifically provided for complete all as specified and directed. |
| 66 | Dismantling timber scantlings 40 sqcm and over in section, in framed section any position like trusses, rafters, purlins etc. complete all as specified and directed. |
| 67 | Dismantling structural steel work including doors, gates but excluding framed truss etc. complete all as specified and directed. |
| 68 | Dismantling plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings incl ridges, hips and valley gutter complete all as specified and directed. |
| 69 | Dimantling of Asbestos cement (corrugated,semi corrugated, etc.) sheets in roof coverings including ridges etc complete all as specified anddirected |
| 70 | Dismantlingwall and ceiling board( fiber, pulp, insulation, etc.) or insulation board/slab/ blankets, any thickness, including cover fillets complete all as specified and directed. |
| 71 | M&L fornewly plastered surface of wall appying two coat of white or tinted oil bound distemper over one coat of alkali resistant priming paint including 02mm thick wall care putty etc complete all as specified and as directed. |
| 72 | M&L for 75mm thick PCC 1:3:6 type C2(Using 40mm graded crushed stone aggregate) as in plinth protectionfinishedeven and smoothusing extra cement.Joints to be given at every 3m interval and corners of buildings and fitted with bituminious mastic or equivalent filler complete all as specified and directed. |
| 73 | M&L for Glazed ceramic tiles coloured 300mmx 450mm , 6 to 7 mm thick as in skirting / dado, set and jointed in neat cement slurry and pointed in white or colour cement to match over and including 10 mm thick rendering in cement mortar 1:4 on fair faces of brick work or concrete surface etc complete all as specified andand as directed |
| 74 | M&Lfor Non Skidceramic tiles (coloured) 7 to 8 mm thick , (square / rectangular) area of each tiles exceeding 0.11 sqm but not exceeding 0.18 sqm as in floor etc, set and jointed in neat cement slurry and pointed with white or coloured cement to matchover and including screed bed or bedding layer 15mm thick in cement mortar 1:6for laying floor finishes etc complete all as specified and directed |
| 75 | M&Lfor Non Skidceramic tiles (coloured) 7 to 8 mm thick , (square / rectangular) area of each tiles exceeding 0.18 sqm but not exceeding 0.38 sqm as in dado/skirting etc, set and jointed in neat cement slurry and pointed with white or coloured cement to matchover and including rendering layer 10 mm thick in cement mortar 1:4etc complete all as specified and directed |
| 76 | M&Lfor Non Skidceramic tiles (coloured) 7 to 8 mm thick , (square / rectangular) area of each tiles exceeding 0.18 sqm but not exceeding 0.38sqm as in floors etc, set and jointed in neat cement slurry and pointed with white or coloured cement to matchover and including screed bed or bedding layer 15 mm thick in cement mortar 1:6for laying floor finishes etc complete all as specified and directed |
| 77 | M&L for rendering 5mm thick on ceiling in cement mortar 1:3 on fair faces of concrete surface finishing surfaces even and smooth without using extra cement complete all as specified and directed. |
| 78 | M&L for rendering 15 mm thick in cement mortar 1:6 on fair faces of brick work or concrete surfaces and finishing surfaces even and smooth without using extra cement complete all as specified and directed. |
| 79 | M&L forrendering 15 mm thick in two layers 10mm +5mm in cement mortar 1:4 on external surfaces of brick work or concrete surfaces with using WPC finishing the surfaces even and smooth without using extra cement complete all as specified and directed.Note:- WPC will be measured and paid separately under respective item of this schedule. |
| 80 | M&L for rendering 20 mm thick in two layers of 10mm thick and 10mm thick in cement mortar (1:4) on fair faces of brick work or concrete surface finsihed even and smooth (without using extra cement) mixed with water proofing compound as per manufacture instruction etc. complete all as specified and as directed.Notes : WPC shall be measured and paid seperately under respective item of this schedule. |
| 81 | M&L forrendering 10 mm thick in cement mortar 1:4 mixed with water proofing compound as per manufacturer instructionon fair surfaces of brick work or concrete surfaces complete all as specified and directed.Note :- The water proofing compoundshall be measured and paid separately under respective item of this schedule. |
| 82 | M&L for preparation of new surfaces and applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces over 1mm thick wall care putty complete all as specified and directed. |
| 83 | M&L preparation of new plastered surfaces of wall and applying two coat of cement base paint over a coat of alkali resistant primer complete all as specified and directed. |
| 84 | M&L for complete removal of old existing treatement of internal wall and appying two coat of oil bound distemper over a coat of alkali registant primer over 02mm thick wall care putty complete all as specified and as directed |
| 85 | M&L for preparation of old surfaces by complete removal of existing treatment and applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over 01mm thick wall care putty complete all as specified and directed. |
| 86 | M&L for preparation of new undecorated surface of ceiling and applying two coats of white wash complete all as specified and directed. |
| 87 | Supply and laying of CPVC pipes outer diameter 20mm SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified and directed. |
| 88 | Supply and laying of CPVC pipes outer diameter 25mm SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified and directed. |
| 89 | S&F in repair 15 mm bore pillar taps fancy type (long neck) cast copper alloy with hot & cold mixturechromium plated screwed down high pressure with or without letter hot or could with long screwed and shanks and fly nuts screwed for iron pipes complete all as specified and as directed. |
| 90 | S&F in repair white vitreous china wash basin white flat back size 550x400 excluding taps but including 32 mm dia chromium platedwaste fitting and PVC waste pipe 610 mm long andMS brackets complete all as specified and as directed |
| 91 | S&F in repairLow density polyethylene(LDPE) pipes bore of pipe in 32mm of pressure rating6 kgf/sq. cmcomplete all as specified and directed |
| 92 | S&F in repair Brass chromium plated shower rose 125mm size with or without swivel joints of standard size including fixing to 15mm steel pipe or union complete all as specified and as directed. |
| 93 | S&F in repairs coloured vitreous china wash down water closet (anglo-indian type) Semi Pedestal Pattern white (excluding flushing cistern & flush pipe) and seat cover incl connection to out going pipe, and flushing pipe complete all as specified and as directed. |
| 94 | S&F in repair PVC valveless double syphonic action type flushing cistern low level of 10 Ltr capacity white with inlet ball valve, float, flushing bend & handle including brackets, suitable for both Indian Type Water Closet & Europeon Type Water closet including brackets & connection to pipe etc complete all asspecifiedand directed. |
| 95 | S&F 35mm thick 2nd class hard wood glazed and skeleton factory made shutter open rebated and prepared to receive glass, gauge etc. without sash bars with edges of framing plain chamferred or rounded, fitted with cut and mitred beads for securing glass etc, size of members of shutters as specified in SSR part-I, Sec-08, Clause 8.2(a), kiln seasoned and chemically pressure treated complete all as specified and directed. |
| 96 | S&F in repair mild steel Helical door spring 300mm long ordinary rat tail type incl roaller & roller plate complete fixed with screws to wooden frames or with welding to steel frames complete all as specified and directed. |
| 97 | Taking down existing un-sreviceable water proofing treatment from roof slab and cleaning the roof by wire brush and removing WPT felt beyond the MOD premises etc. complete all as specified and directed. |
| 98 | S&F finial fancy type for curtain rod in pair etc complete all as specified and as directed. |
| 99 | S&F bracket for curtain rod in pair etc complete all as specified and as directed. |
| 100 | M&L for waterproofing coating by providing and applying Fosroc Brushbond Roof Guard of FOSROC or equivalent of SIKA/STP , a single component High build fibre Reinforced Acrylic waterproofing render for roofing system applied by brush, at three coats at minimum dry film thickness of 1 mm, cured by reaction with atmospheric moisture to give a tough elastomeric waterproof membrane complete all as per manufacturer specification, specified and directed.Solid Content - 70%, Tensile strength ASTM D 412-1.10 Mpa, Elongation ASTM D12-100%, Resistance to ageing due to - 1000hours, UV radiation ASTM D4587 E - No Change, Rapid Chloride Penetration ASTM c 1202 - Very low, Pull off adhesion ASTM D541 - 0.92 Mpa, Resistance to Algae growth ASTM D 5589-97 - Passes, Zero rating, Permeability (mm) (BSEN 12390 part 8) -n 5.0, Water vapour transmission (ASTM E 96) - 6.0g/m2 h |
| 101 | Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc.removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc as per existing specification complete all as specified and directed. |
| 102 | M&L for concealed point wiring with FRLSH PVC insulated unsheathed multistranded copper conductor cables 1100 Volts grade of 1.5 sqmm size alongwith one earth continuity conductor with FRLSH PVC insulated unsheathed multistranded copper conductor cable 1100 Volts grade of 1.5 sqmm size through and including 20mm dia (medium grade) rigid non metallic PVC concealed conduit terminated in and including pressed steel sunken boxes , readily available (Having wall thickness not less than 1.22 mm for boxes upto a size of 200 mmX300 mm and beyond that the wall thickness shall be not less than 1.63 mm) concealed type with 3mm thick bakelite sheet coverfor fixing of switches, sockets, fan regulators etc including testing on completion complete including cutting chases for concealed conduit pinning in making good to facing and pointing in using cement mortar 1:3 and making good to disturbed surface complete all as specified and directed for the followings: - |
| 103 | One light point/ Bell/ one fan point controlled by one switch |
| 104 | One 3 pin socket outlet, 6 Amp on the same board with other switches |
| 105 | One 3 pin socket outlet, 6 Amp independent |
| 106 | M&L for concealed point wiring with FRLSH PVC insulated unsheathed multistranded copper conductor cables 1100 Volts grade of 2.5 sqmm size alongwith one earth continuity conductor with FRLSH PVC insulated unsheathed multistranded copper conductor cable 1100 Volts grade of 2.5 sqmm size through and including 20 mm dia (medium grade) rigid non metallic PVC concealed conduit terminated in and including pressed steel sunken boxes , readily available (Having wall thickness not less than 1.22 mm for boxes upto a size of 200 mmX300 mm and beyond that the wall thickness shall be not less than 1.63 mm) concealed type with 3mm thick bakelite sheet coverfor fixing of switches, sockets, fan regulators etc including testing on completion complete including cutting chases for concealed conduit pinning in making good to facing and pointing in using cement mortar 1:3 and making good to disturbed surface complete all as specified and directed. |
| 107 | S&F Switch piano, flush type single pole, one way 6 Ampcomplete all as per specified and directed. |
| 108 | S&F Switch piano, flush type single pole, one way 16 Ampcomplete all as per specified and directed. |
| 109 | S&F Socket outlet 2 in 1, 6 pin, 6 and 16 amp flush typecomplete all as per specified and directed. |
| 110 | S&F Socket outlet 2 in 1, 5 pin, 6A complete all as per specified and directed. |
| 111 | S&F Sheet metal enclosure powder coated for MCB DB double door single pole & Neutral 8 way with 200Amp common bus bar at incomming complete all as specified and directed. |
| 112 | S&F Ceiling rose, 3 phase/PVC/polycarbonate, isolated body complete all as per specified and directed. |
| 113 | M&L for Earthing complete with galvanised steel earth plate electrode 60×60cm.× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less\"than 1.5 metres below normal ground level, connected to galvanisediron earth strip 25x4mm by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 connected to earthing test point all as specified or indicated including testing on completion complete all as specified and directed. |
| 114 | Taking down ceiling fan of any sweep and keping in safe custody and deposited to MES store Yard complete all as specified and directed. |
| 115 | S&F stepped type electronic fan regulator flush type on the existing phenolic laminated sheet etc. as reqd complete all as specified and directed. |
| 116 | M&L for sub main wiring with 2 run of FRLSH PVC insulated & unsheathed multistranded copper conductor of nominal cross sectional area 4.0 sqmm alongwith one run of FRLSH PVC insulated & unsheathed multistranded copper conductor of nominal cross sectional area 4.0 sqmm as earth continuity conductor drawn through and including PVC conduit complete all as specified and directed.Note: For concealed sub-main wiring cutting chases will be included in quoted rate. |
| 117 | M&L for sub main wiring with 2 run of FRLSH PVC insulated & unsheathed multistranded copper conductor of nominal cross sectional area 6.0 sqmm alongwith one run of FRLSH PVC insulated & unsheathed multistranded copper conductor of nominal cross sectional area 6.0 sqmm as earth continuity conductor drawn through and including PVC conduit 25mm complete all as specified and directed.Note: For concealed sub-main wiring cutting chases will be included in quoted rate. |
| 118 | Supply and fixing 240V, 10KA \"C\" curve single pole miniature circuit breaker (MCB) 6 to 32 Amps,in the MCB DB complete with connection testing and commissioning. complete all as specified and directed. |
| 119 | Supply and fixing240V, 10KA \"C\" curve SPN miniature circuit breaker (MCB) 6 to 32 Amps,in the MCB DB complete with connection testing and commissioning. complete all as specified and directed. |
| 120 | Supply and fixing240V, 10KA \"C\" curve SPN miniature circuit breaker (MCB) 40 to 63 Amps,in the MCB DB complete with connection testing and commissioning. complete all as specified and directed. |
| 121 | Supply and fixing ceiling fans complete with blades, down rods, electronic regulator and accessories, 230V,1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC) complete all as specified and directed. |
| 122 | S & F for wall mounted LED tube light fitting 20 watts batten for surface mounted, anodized extruded aluminium housing, high transmissitivity diffuser, high lumen ouput box type fitting, 230 volts and intregrated electronic driver connector block etc complete with all accessories internally pre wired and necessary mounting arrangements, provision of new 3 core multistranded copper conductor of size 23/0.193 from ceiling rose to fitting complete all as specified and directed. |
| 123 | Supply and fixing LED tube light batten box type made of CRCA sheet with decorative end caps suitable with ultra bright glass LED tube light 1x 18/20 watt T8 type single side connection complete with both end bi-pin holder and all accessories internally prewired and fixed to wall/ceiling incl fittings accessories and connecting up with twin core flexible copper conductor cable suitable size complete all as specified and directed. |
| 124 | S & F for Energy saving new generation environmental friendly long life versatile presure die cast aluminium IP 66 for security light fitting luminaire with high power LEDs as light source and electronic driver of capacity 25 watts with pre wired and necessary mounitng arrangements and provision of 1.5 sq mm three core copper dia GI pipe medium grade bracket 1.5 mtr long bend to required shape with clamps, nut, bolts complete all as directed. |
| 125 | S&F energy saving new generation 10 watt LED bulk head fitting made of aluminium die cast housing IP 65 luminaries with opal diffuser prewired with warranty option of 5 years from date of installation and necessarymounting arrangements, provision of new 3 core multistranded copper conductor of size 23/0.193 from ceiling rose to fitting including LED bulbcomplete all as specified and directed. |
| 126 | S & F for energey efficient exhaust fan of 300mm sweep made of metal body ventil Air-DS type complete with louver with bolts nuts and washers size of the bolt 15 cm long 12mm dia embedded in the wall including provision of PVC flexible copper cable of size 23/0.0076 two core from ceiling rose to exhaust fan for connection and making suitable size of hole to existing brick wall for fan base complete all as directed by GE. |
| 127 | S & F for wall mounted LED tube light fitting 10 watts batten for surface mounted, anodized extruded aluminium housing, high transmissitivity diffuser, high lumen ouput box type fitting, 230 volts and intregrated electronic driver connector block etc complete with all accessories internally pre wired and necessary mounting arrangements, provision of new 3 core multistranded copper conductor of size 23/0.193 from ceiling rose to fitting complete all as specified and directed. |
| 128 | Taking down of old sub main wiring any size and any type including batten/ conduit/ casing at any indicated situation complete all as specified and directed. |
| 129 | Taking down of Old MCB DB / control box any type any size including MCCBs/MCBs, isolator etc and making gooddisturbed surface complete all as specified and directed. |
| 130 | S&F electric water heater (Geyser),vertical storage type, 230 V, 50 Hz, stainless steelinner tank,heating element copper with nickle coated 2 KW, 8 bar pressure, capacity 25 litre, BEE 5 Star ratedthermostate (capaliary tube),thermal cutout, Multifunctional valve ( NRV/PRV/Drain), Dry heat protection, Weather proof IP-X4, Heavy duty magnesium anode, High grade ABS material outer body, High Density Puf for high energy efficiency, stainless steel connection pipe etc complete with all accessories withWarranty 2 Year for Geyser, 7 Years for Inner tank and 3 Years for Heating Element. including taking down unserviceable one and deposited to MES Yard complete all as specified and directed. |
| 131 | (Note : The Scope of Work contained in \"Sch of Credit\" amounting to Rs. 92,964.00 The Quoted sum shall be arrived at after deducting the amount of “Sch of Credit” from the total amount of the ‘BoQ’ |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail