Tender For Revised Providing And Fixing Residual Chlorine Analyzer Installed Indicator Along With Full Mechanism To Link With Scada System, Including 3 Years O&M And All Other Works Contingent Thereto At 13 Mld Stp Fazilka, Distt. Ferozepur. (Under J, Ferozepur-Punjab
TDR : 54029383
Tender Notice
BOQ
9 Days Left
Ferozepur
Punjab
Tender For Revised Providing And Fixing Residual Chlorine Analyzer Installed Indicator Along With Full Mechanism To Link With Scada System, Including 3 Years O&M And All Other Works Contingent Thereto At 13 Mld Stp Fazilka, Distt. Ferozepur. (Under J
Name of Work:- Revised Providing And Fixing Residual Chlorine Analyzer Installed Indicator Along With Full Mechanism To Link With Scada System, Including 3 Years O&M And All Other Works Contingent Thereto At 13 Mld Stp Fazilka, Distt. Ferozepur. (Under Jal Hi Amrit)
Sl. No.
Item Description
1
Providing & Fixing Residual Chlorine Analyzer installed indicator along with full mechanism to link SCADA system.➤ Residual Chlorine Analyzer Range: Sppm, Sample pit range 85 Materials of Construction Body Material PVC, Membrane Cap Material PVC housing, Proprietary Membrane Measuring Water Temperature & Pressure 0 to 45° C & 14.7 psig (1 Bar), sensor protection IP-65 Cross Sensitivity Chlorine dioxide, ozone, bromines, lodine with Isd 20m A output, 1xRS-485, Display 4 Digit, 7 segment, Red, Character height of 0.56,pH Compensation Mannual PH value entry through keypad, Transmitter Power Supply 85 to 230 VAC, 50/60Hz.➤ Power Coated and CNC fabricated electric control panel for Automation System of 14 SWCG CRCA sheet thickness and wiich include PLC (Programmable logic controller) with appropriate digital and analog inputs and outputs to give automatic commands to field equipment, Electronic relay card 8 channel, SMPS 4.5 Amps to energise PLC system, HMI (Human Machine Interface) 7\" display for Monitoring and Controlling Mobile App (Android/105) with User ID and Password to monitor and control the pumping operation from Mobile for 3 users, GSM Based device to send data to server, remote monitor and control the operation of chlorinator and also to analyze the history logging, fault status, fault history, Power Quality Parameters like PF, Current Voltage, KWH etc.➤ Integration of Data with the existing server.
2
Operation and maintenance service for the Residual Chlorine Analyzer:Residual Chlorine Analyzer Maintenance1. Monthly Maintenance: - Perform routine maintenance tasks, including cleaning and inspecting the analyzer, to ensure optimal performance. -Check and replace worn-out or damaged parts, Such as sensors.2. Calibration: -Calibrate the Residual Chlorine Analyzer on a monthly basis to ensure accurate readings. - Use calibrated standards and follow the manufacturer\"s instructions for calibration.3. Functionality Check: -Verify that the analyzer is functioning correctly and providing accurate readings. -Identify and troubleshoot and issues or faults with the analyzer4. Record Keeping: -Maintain detailed records of maintenance activities, calibration, and repair of the ResidualChlorine AnalyzerThe scope of work shall be for a period of 3 years from the date ofcommencement Please Enable Macros to View BoQ information