| 1 | Section 100-For 300/400 SERIES LOWER TERRACE LEVEL. Total EIGHT houses to be covered. |
| 2 | Removal of China mosaic, Brick bat coba water proofing to exposing the RCC slab to accommodate insert plate of size 250 mm x 300 mm including re-doing the same treatment again ( using good quality water proofing compound also and testing) after installation of Insert plates as per suggested by in charge Engineer. The rate shall be inclusive of necessary scaffolding, etc. complete. Actual quantity to be measured and paid. (For information - Quantity break up -One building LT = 8 nos. x 8 buildings = 64 nos.) |
| 3 | Providing ,Fabricating & Erection of M.S. 10 mm thick Insert plates (250 mm x 300 mm) andFOUR SIDE 6 mm junction plates,stiffners,end closer arch,end closer purlinfor roofing with all necessary required hardware and fillet weld etc. with TWO OR MORE COATS of enamel paint over one coat of primer as per suggested by in cgarge Engineer. The rate shall be inclusive of necessary scaffolding etc. complete. Actual quantity to be measured and paid.(For information - Quantity break up -One building = 170 kg. x8 buildings =1360kgs.) |
| 4 | Providing, Fabricating & Erection of HILTI/ITW / FISCHER CHEMICAL Anchor fasteners 12 mm Dia x 100 mm for fixing insert plates on existing RCC slab/ Brick wall with all necessary required chemicals etc. as per suggested by in charge Engineer. The rate shall be inclusive of necessary scaffolding etc. complete. Actual quantity to be measured and paid. (For information - Quantity break up -One building = 32 x 8 buildings =256nos.). First Choice is HILTI chemical fastners |
| 5 | Providing ,Fabricating & Erection of M.S. pipe structure / BOX sections ( RHS 96 x 48 x 4 mm ) for roofingwith all necessary required hardware and fillet weld etc. with TWO OR MORE COATS of enamel paint over one coat of primer as per suggested by in charge Engineer. TATA or ASIAN TUBE as approved by the in charge Engineer. The rate shall be inclusive of necessary scaffolding etc. complete. Actual quantity to be measured and paid. WESTAGE WILL NOT BE CONSIDERED FOR PAYMENT.(For information - Quantity break up -One building = 900 x 8 buildings = 7200 KGS) |
| 6 | Providing & fixing STAIGHT in position EXTRUDED PROFILED POLY CARBONATE CLEAR EMBOSSED COMPACT SHEET having 2.00 mm thickness. Single length with Screwed down to the purlin with SDST screws with coating class-3, HOT DIP galvanized of size 12 gauge, 14 TPI, 55 mm long. Number of screws shall be minimum 4 per SQM. WithEPDM washers of 19 to 23 mm Diameter as per suggeste by in charge Engineer. The make shall be PALRAM, TUFLITEor Equivalent as approved by in charge Engineer. Overlapping along length shall be about 58 mm. The rate shall be inclusive of necessary scaffolding etc. complete. Actual quantity to be measured and paid. OVERLAPS WILL NOT BE CONSIDERED FOR PAYMENT.(For information - Quantity break up -One building = 65 x 8 buildings =SQM) |
| 7 | Section 200-For 300/400 SERIES UPPER TERRACE LEVEL |
| 8 | Removal of China mosaic, Brick bat coba water proofing exposing the RCC slab to accommodate insert plate of size 250 mm x 300 mm including re-doing the same treatment again ( using good quality water proofing compound also) after installation of Insert plates as per Architectural drawings & details. The rate shall be inclusive of necessary scaffolding, etc. complete. Actual quantity to be measured and paid. (For information - Quantity break up -One building = 12 x 2 buildings =24 nos.) |
| 9 | Providing ,Fabricating & Erection of M.S. 10 mm thick Insert plates (250 mm x 300 mm) and6 mm junction platesfor roofing with all necessary required fillet weld etc. with TWO COATS of enamel paint over one coat of primer as per Architectectural drawings & details. The rate shall be inclusive of necessary scaffolding etc. complete. Actual quantity to be measured and paid. (For information - Quantity break up -One building = 260 x 2 buildings = 520 kgs) |
| 10 | Providing, Fabricating & Erection of HILTI/ITW / FISCHER CHEMICAL Anchor fasteners 12 mm Dia x 100 mm for fixing insert plates on existing RCC slab/ Brick wall with all necessary required chemicals etc. as per suggested by in charge Engineer. The rate shall be inclusive of necessary scaffolding etc. complete. Actual quantity to be measured and paid. (For information - Quantity break up -One building = 48 x 2 buildings = 96 nos.). First Choice is HILTI chemical fastners |
| 11 | Providing ,Fabricating & Erection of M.S. pipe structure / BOX sections ( RHS 96 x 48 x 4 mm ) for roofingwith all necessary required fillet weld etc. with TWO OR MORE COATS of enamel paint over one coat of primer as per Architectectural drawings & details. TATA or ASIAN TUBE as approved by the Engineer. The rate shall be inclusive of necessary scaffolding etc. complete. Actual quantity to be measured and paid. WASTAGE WILL NOT BE CONSIDERED FOR PAYMENT. (For information - Quantity break up -One building = 1400 x 2 buildings = 2800 kgs) |
| 12 | Providing & fixing in position CURVED EXTRUDED PROFILED POLY CARBONATE CLEAR EMBOSSED COMPACT SHEET having 2.00 mm thickness. Single length up to 6.10 meter, overall width 1072 mm, cover width 1015 mm. Screwed down to the purlin with SDST screws with coating class-3, HOT DIP galvanized of size 12 gauge, 14 TPI, 55 mm long. Number of screws shall be minimum 4 per SQM. WithEPDM washers of 19 to 23 mm Diameter as per suggested by in charge Engineer. The make shall be PALRAM, TUFLITEor Equivalent as approved by in charge Engineer. Overlapping along length shall be about 58 mm. The rate shall be inclusive of necessary scaffolding etc. complete. Actual quantity to be measured and paid. OVERLAPS WILL NOT BE CONSIDERED FOR PAYMENT. (For information - Quantity break up -One building = 125 x 2 buildings = 250 SQM) |