| Sl. No. | Item Description |
| 1 | EXCAVATION upto 1.50 Metre for foundation such as footing, pedestals, walls, drains, columns, ramps, plinth beams, cable trenches in Dense or Hard soil MECHANICALLY but other than hard rock including shoring, strutting, sorting out and stacking useful material, dewatering where required, cutting vegetation up to 1.5m ht if required and disposing off the excavated stuff upto all lead and lift.Note- All types of soil that can be removed by JCB/ Poclain bucket shall be classified under this item. |
| 2 | EXCAVATION 1.50 to 3.00 Metre for foundation such as footing, pedestals, walls, drains, columns, ramps, plinth beams, cable trenches in Hard Murrum MECHANICALLY but other than hard rock including shoring, strutting, sorting out and stacking useful material, dewatering where required, and disposing off the excavated stuff upto all lead and lift. |
| 3 | EXCAVATION 1.50 to 3.00 Metre for foundation such as footing, pedestals, walls, drains, columns, ramps, plinth beams, cable trenches in Soft rock not requiring blasting but other than hard rock including shoring, strutting, sorting out and stacking useful material, dewatering where required, and disposing off the excavated stuff upto all lead and lift |
| 4 | EXCAVATION 3.00 to 5.00 Metre for foundation such as footing, pedestals, walls, drains, columns, ramps, plinth beams, cable trenches in Soft rock including shoring, strutting, sorting out and stacking useful material, dewatering where required, and disposing off the excavated stuff upto all lead and lift |
| 5 | EXCAVATION 3.00 to 5.00 Metre for foundation such as footing, pedestals, walls, drains, columns, ramps, plinth beams, cable trenches in Hard rock including shoring, strutting, sorting out and stacking useful material, dewatering where required, and disposing off the excavated stuff upto all lead and lift |
| 6 | FILLING with selected & approved available excavated earth (excluding rock) in excavated pits, trenches, in plinth, sub-base for of roads,drains, manhole, sumps, or where required with approved locally available materials including spreading in layers not exceeding 200mm, watering, ramming, compacting mechanically using 2 ton compactor etc, complete.Measurements for net volume of space occupied by filling.If desired by the engineer-in-charge the contractor shall at his own expense carry out modified proctor compaction test to determine the maximum dry density.The criteria for acceptance of filling shall be compacting to 95% modifiedProctor density with use of mechanical roller/rammer etc complete as directed and instructed by Engineer-in-charge. Volume of material filled to be measured for payment. |
| 7 | FILLING with selected & approved Murrum material brought by Contractor from outside client\"s premises, including Identification ofBorrow pits and including Royalty charges & or duties as per requirement oflocal authority, in foundations, excavated pits, trenches, in plinth, sub-base for of roads,drains, manhole, sumps, or where required with approved locally available materials including spreading in layers not exceeding 200mm, watering, ramming, compacting mechanically using 2 ton compactor etc, complete.Measurements for net volume of space occupied by filling.If desired by the engineer-in-charge the contractor shall at his own expense carry out modified proctor compaction test to determine the maximum dry density.The criteria for acceptance of filling shall becompacting to 95% modifiedProctor density with use of mechanical roller/rammer etc complete as directed and instructed by Engineer-in-charge. Volume of material filled to be measured for payment. |
| 8 | Providing and laying RUBBLE SOLING wherever required in foundation and plinth including hand packing fillings interstices with chips and sand.Watering and compacting to consolidated thickness, etc complete as directed by engineer-in-charge |
| 9 | Providing material and labour for laying PLINTH PROTECTION including excavation of 30 cm depth and Filling with dry bricks bats of 20 cm thick and top layers C.C. 1:2:4 ( 1 cement 2 coarse sand: 4 graded stone aggregate 20m nominal size)50mm thk finished in proper grade and slop etc. completeas directed by engineer-in-charge |
| 10 | Carring out plinth treatment to post construction / existing structure by spraying chemical solution for termite control treatmentincluding labour and material consistment with I.S.I specification.Using Chlordene and Chiorpurfiles 20 EC. As Per 6131_paret-II Consentration Weight one percent is recommended i.e one LTR. 20 EC chemical emulsion with 19 liter give 1 % concrentration inclusive of one LTR. chemical emulsion appication at the rate of 5 LTR. chemical / Sqm of surface is recommended as per I.S. treated Plinth area of structureto be measured for payment as directed by engineer-in-charge |
| 11 | Providing and laying Granular subbase (GSB) for preparing base of road,trenches, in plinth, sub-base for of roads,drains, manhole, sumps, or where required by providing close graded Material, mixing in a mechanical mix plant at OMC(Optimum Moisture Content), carriage of mixed Material to work site, spreading in uniform layers with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete. |
| 12 | Providing and laying PLAIN CEMENT CONCRETE 1:2:4 (1- Cement : 2- Coarse sand : 4- gradedstone aggregates 20 mm nominal size) in foundations and superstructure including, machine mixing, leveling compacting, curing and formwork if any, scaffolding, stagingetc. complete as directed and instructed by Engineer-in-Charge. Volume of PCC laid to be measured for payment. |
| 13 | Providing material and labour for laying machine mixed/machine batched/RMC controlled cement concrete M.250 using graded black trap stone aggregates of maximum 20mm nominal (down graded) size including fine aggregate confirming to IS 383 with minimum cement content as per IS456 (without flyash) for durability shall be followed as per approved design mix & latest IS456 for reinforced cement conrete work for all elements,all floors,all heights/depths, any lead and lift including cost of formwork with sheathing steel or form finish ply shuttering , scaffolding, staging, vibrating, compacting, finishing andcuring complete but excluding cost of reinforcement for reinforced concrete work in Foundations,footings, Baseof columnsandMass concrete, as directions of Engineer in charge Complete.Preliminary cubes to be prepared on award of work and to be tested to meet the specified requirement for M25 mix, design mix to be approved by the Engineer-in-charge/Architect. Concrete placing shall be done with utmost care, the free drop height shall not exceed 1.5m, and concrete shall be vibrated with immersion type vibrators having frequency not less than 7000 vibrations per second in methodical method so as all points of structures are covered. Free concrete surface shall be covered with Hessian cloth and kept wet. |
| 14 | Providing material and labour for laying machine mixed/machine batched/RMC controlled cement concrete M.250 using graded black trap stone aggregates of maximum 20mm nominal (down graded) size including fine aggregate confirming to IS 383 with minimum cement content as per IS456 (without flyash) for durability shall be followed as per approved design mix & latest IS456 for reinforced cement conrete work for all elements,all floors,all heights/depths, any lead and lift including cost of formwork with sheathing steel or form finish ply shuttering, scaffolding, staging, vibrating, compacting, finishing andcuring complete but excluding cost of reinforcement for reinforced concrete work in Columns, Pillars posts and struts etc complete as directed by Engineer-incharge. Preliminary cubes to be prepared on award of work and to be tested to meet the specified requirement for M25 mix, design mix to be approved by the Engineer-in-charge/Architect. Concrete placing shall be done with utmost care, the free drop height shall not exceed 1.5m, and concrete shall be vibrated with immersion type vibrators having frequency not less than 7000 vibrations per second in methodical method so as all points of structures are covered. Free concrete surface shall be covered with Hessian cloth and kept wet. |
| 15 | Providing material and labour for laying machine mixed/machine batched/RMC controlled cement concrete M.250 using graded black trap stone aggregates of maximum 20mm nominal (down graded) size including fine aggregate confirming to IS 383 with minimum cement content as per IS456 (without flyash) for durability shall be followed as per approved design mix & latest IS456 for reinforced cement conrete work for all elements,all floors,all heights/depths, any lead and lift including cost of formwork with sheathing steel or form finish ply shuttering , scaffolding, staging, vibrating, compacting, finishing andcuring complete but excluding cost of reinforcement for reinforced concrete work in Lintels,Beams, Girders and Cantilever etc complete as directed by Engineer-incharge.Preliminary cubes to be prepared on award of work and to be tested to meet the specified requirement for M25 mix, design mix to be approved by the Engineer-in-charge/Architect. Concrete placing shall be done with utmost care, the free drop height shall not exceed 1.5m, and concrete shall be vibrated with immersion type vibrators having frequency not less than 7000 vibrations per second in methodical method so as all points of structures are covered. Free concrete surface shall be covered with Hessian cloth and kept wet. |
| 16 | Providing material and labour for laying machine mixed/machine batched/RMC controlled cement concrete M.200 using graded black trap stone aggregates of maximum 20mm nominal (down graded) size including fine aggregate confirming to IS 383 with minimum cement content as per IS456 (without flyash) for durability shall be followed as per approved design mix & latest IS456 for reinforced cement conrete work for all elements,all floors,all heights/depths, any lead and lift including cost of formwork with sheathing steelor form finish ply shuttering, scaffolding, staging, vibrating, compacting, finishing andcuring complete but excluding cost of reinforcement for reinforced concrete work in Slabs, landing, shelves andCantilever etc complete as directed by engineer-incharge.Preliminary cubes to be prepared on award of work and to be tested to meet the specified requirement for M20 mix, design mix to be approved by the Engineer-in-charge/Architect. Concrete placing shall be done with utmost care, the free drop height shall not exceed 1.5m, and concrete shall be vibrated with immersion type vibrators having frequency not less than 7000 vibrations per second in methodical method so as all points of structures are covered. Free concrete surface shall be covered with Hessian cloth and kept wet. |
| 17 | Providing material and labour for laying machine mixed/machine batched/RMC controlled cement concrete M.250 using graded black trap stone aggregates of maximum 20mm nominal (down graded) size including fine aggregate confirming to IS 383 with minimum cement content as per IS456 (without flyash) for durability shall be followed as per approved design mix & latest IS456 for reinforced cement conrete work for all elements,all floors,all heights/depths, any lead and lift including cost of formwork with sheathing steelor form finish ply shuttering , scaffolding, staging, vibrating, compacting, finishing andcuring complete but excluding cost of reinforcement for reinforced concrete work in Slabs, landing, shelves and Cantilever etc complete as directed by Engineer-incharge.Preliminary cubes to be prepared on award of work and to be tested to meet the specified requirement for M25 mix, design mix to be approved by the Engineer-in-charge/Architect. Concrete placing shall be done with utmost care, the free drop height shall not exceed 1.5m, and concrete shall be vibrated with immersion type vibrators having frequency not less than 7000 vibrations per second in methodical method so as all points of structures are covered. Free concrete surface shall be covered with Hessian cloth and kept wet. |
| 18 | Providing, laying and fixing in position REINFORCEMENT High yield deformed bars/TMT/ FE500/FE500D/FE550 forR.C.C. works at all levels including cutting, bending and binding with 16 gauge M.S. annealed wire, providing cover blocks of C.M. 1:2 Embedded with binding wire etc. complete. The reinforcement detailing to IS 456 or, if specified by engineer, shallconformto IS: 13920 (Ductile detailing of R. C. Structures),bars as per IS 1786 the rate shall be inclusive of executing such detailing. Laps to be measured shall be as shown in drawing and for reinforcement length longer than available in market. Chairs, pinsand laps other than that specified shall not on be measured and paid for. No extra to be paid for height, rate remains same at all levels, complete as per drawings, specification, direction ofengineer-incharge. Make: TATA, SAIL, JSW or as approved byengineer-in-charge Complete. |
| 19 | Providing material & labour for laying Rebar in Existing Column, Beam and Slab including all dia. Of bars 8mm to 32mm as per drawing and specification as directions of Chief Engineer in charge Complete. Make Hilti or Fischer or its equivalent as approved by engineer-in-charge |
| 20 | Providing material and labor for Structural steel work (Confirming to IS 4923-1997) riveted, bolted or welded in builtup, conventional, Hollow section, etc for all type sections, in framed work, railing work, any type of fabrication work, including cutting, hoisting, fixing in position and applying a priming coat &two coat applying synthetic enamel paint of approved steel primer all complete as per the structural designs and as directions ofEngineer- in -Charge Complete. |
| 21 | Brick work using common burnt clay building bricks including scaffolding, raking of joints, curing using first class bricks having min. comp. Strength 35 kg/cm2 of approved manufacturer in foundation and plinth in Cement Mortar 1:6 (1- Cement : 6 -fine sand)(B)ConventionalAll bricks and shallbe soaked in waterfor at least 24 hours before use.bricks used for masonry work shall be as available locally, but approvedbefore start of work. volume of masonry to be measured for payment. |
| 22 | Providing & fixing LIGHT WEIGHT MASONRY BLOCKS of- Sand Based Autoclaved Aerated Concrete blocks (AAC Blocks) of any thickness using Epoxy based jointing adhesiveof approved make, upto all floor level/all heights, masonry walls in jointing mortar, complete as per Technical specification, density of blocks shall not exceed 700 kg/cum, using bonding material supplied by the manufacturer as per their instructions, including necessary scaffolding for fixing, in line & level. Volumne of blocks erected to be measured for payment. R.C.C. coping of size-wall thickness x 100mmht. at 0.91m intervals shall be provided including reinforced with 2 Numbers 6mm diameter horizontalbars and8mm diameterat 200 c/cties. R.C work not to be measured separately but included in rate.other specifications as directions of Engineer in Charge Complete |
| 23 | Providing and laying 10mm thick in single coat CEMENT PLASTER in (i)Cement mortar 1:3 (1-cement:3-sand) at all height/all floors to internal surfaces of all elements, walls, R.C.C. work, Ceiling,[backing coat at places where glazed or ceramic tiles are to be fixed etc]. including hacking of concrete surfaces, racking of joints, scaffolding, curing, providing chicken mesh at all necessary joints, etc. complete. Final finished surface shall be little rough , so it has proper bonding to paint putty.The surfaces to be plastered to be hacked immediately on de-shuttering. The Brick/ RCC surface to be plastered to be cured sufficiently before start of plaster. Initial bare surface area to be Plastered shall be measured for payment unless noted otherwise, etc as directions of Engineer in charge Complete. |
| 24 | Providing and laying 20mm thick SANDFACED CEMENT PLASTER of required grain finishing upto all height/all floors includinggrooves,pattas etc. in two coats having the the base coat of not less than 12 mm thickness in CM 1:3 (1-cement : 3-sand) & finished coat 8 mm thk, in CM 1:1 (1-cement : 1-sand) to external surfaces of concrete & masonry including hacking of concrete surfaces, racking of joints, scaffolding, curing, providing chicken mesh at all necessary joints, etc. complete. Rate shall include addition of “Impermo” water proofing compound or equivalent as approved by engineer-in-charge, providing, adding & mixingoffine fibrillated 100% virgin polypropylene fibers in cement mortar to formhomogeneous mixture @125 gms per a bag of cement in both the coats of plaster, 12mm long fibers shall be used in first coat & 6mm long fibers shall be used in second finished coat. providing drip mould 40mm wide and 12mm thick in cement mortar 1:3 on soffit of chajjas, canopies, gutters etc.complete. as directions of Engineer in charge Complete.The surfaces to be plastered to be hacked immediately on de-shuttering. The Brick/ RCC surface to be plastered to be cured sufficiently before start of plaster. Initial bare surface area to be Plastered shall be measured for payment unless noted otherwise, etc as directions of Engineer in charge Complete. |
| 25 | Providing material and labor for applying Two coats of gypsum upto desired thickness for getting undulation free surface and accurate plumbness in walls. including providing grooves as per architectural drawings at all the edges of windows/Doors with neat finish on new/existing wall surface to give an even shade including thoroughly brushing the surface free from mortar dropping and other foreign matter and sand papered smooth.make the surface uniform and levelled and must be without any undulation asdirected by engineer in charge complete.Make: Diamond gypsum or as approved by engineer-in-charge. |
| 26 | Providing material and labor for applying Two coats of acrylic putty upto desired thickness for getting undulation free surface and accurate plumbness in walls. including providing grooves as per architectural drawings at all the edges of windows/Doors with neat finish on new/existing wall surface Work includes surface cleaning, removal of loose particles, minor leveling, and application of putty in one or more coats to accurately achieve the required thickness. After proper curing, the surface will be sanded to a smooth, even finish suitable for painting. Thickness will be checked for accuracy throughout the application to ensure compliance with project specifications. |
| 27 | Providing material & labour for Internal Wall painting (two coats) with Luxury Emulsion of approved brand and manufacture including suitable primer coat on undecorated wall surface to give an even shade including throughly brushing the surface free from mortar droppings and other foreign matter and sand papered smooth. asdirected by engineer in charge complete. One component waterborne 100% pure acrylic interior eggshell emulsion that must offer protection against different varieties of bacteria and fungus. Paint should free of HCHO, APEO and have crack bridging property of min 0.9 mm with class 1 flame spread resistanceThe product shall have a Volume Solids of minimum 35%The product shall be independently tested and approved for properties alike resistance to bacterial and fungal species, crack tolerance and flame spread resistance.The coating shall contribute to satisfying the following credit(s): Indoor Environmental Quality (IEQ) under LEED® 2009 Environmental Quality (EQ) and Materials and Resources (MR) under LEED® v4This product shall have a VOC limit not more than 24 g/lit.The product can be like Asian paint Royale series or approved equivalents.Two Coats of above paint should be applied using conventional Roller / Airless spray at the site after application and drying of applied Putty-Primer. Formeasurement of painting items the area painted shall be considered without any multiplication factor for different kinds of surfaces painted. Rate shall be quoted accordingly. All painting items final finish shall be as per manufacturer\"sspecification as per acceptance of Engineerin charge /Architect. No extra payment shall be made for extra/over coat if required.The rate shall be inclusive of providing bamboo scaffoldingMake: Jotun,Asian Paints, Berger Paints, Dulux Paints or equivalent.Guidelines for application1. Surface Preparation - Inspection: Assess the wall surface for defects like cracks, moisture, or old paint layers. All imperfections must be fixed before starting the painting process. - Cleaning: Clean the wall to remove dust, grease, and loose particles. Use a mild detergent solution or a vacuum to ensure a clean surface. - Repair: Fill cracks, holes, and other imperfections with a suitable filler (e.g., putty or spackle). Sand the area smooth after drying. - Priming: Apply a suitable primer to the wall to ensure proper adhesion of the artistic paint. Choose a primer based on the wall material (e.g., masonry, drywall, plaster). Allow the primer to dry according to the manufacturer\"s instructions. 3. Application Process - Base Coat: - Apply a base coat of paint, using a roller for large areas and a brush for edges and corners. Choose a base color that complements the final artistic design. - Allow the base coat to dry completely - Artistic Painting: - As per details provided by architect, Plan the design by sketching it lightly on the wall with a pencil or chalk & get necessary approval from architect or engineer-in-charge. Post approval proceed for final application. 4. Finishing - Sealing (Optional): Apply a clear sealer or varnish over the artwork for added protection, a matte, satin, or gloss finish based on the desired effect.6. Quality Standards - Adhesion: Paint should adhere firmly to the wall without peeling or flaking. - Finish: The final surface should be even, free of brush marks, and match the intended artistic design. - Durability: The painted surface should withstand normal wear and cleaning without damage |
| 28 | Providing and Applying Distemper Paint with work includes providing and applying dry distemper or oil-bound distemper on internal wall surfaces, in required shade, complete as directed by the Engineer-in-Charge. The material shall be of approved brand and manufactured in accordance with relevant quality requirements. Only pre-approved shade and material shall be used.Before application, the surface must be thoroughly cleaned to remove dust, dirt, oil, grease, organic growth, loose particles, old flaking paint and any other foreign matter. All cracks, dents and surface undulations shall be repaired using approved wall putty or plaster of Paris, and the surface shall be made smooth using sandpaper. The surface shall be properly dried and cleaned before application.One coat of approved primer shall be applied over the prepared surface. Primer shall be alkali-resistant where needed and suitable for the distemper system used. After the primer completely dries, the surface shall be sanded again lightly to ensure an even and smooth finish.Two or more coats of approved quality distemper shall then be applied uniformly with brush or roller to obtain even shade and uniform finish. The material shall be mixed and diluted only as per manufacturer’s specifications. The coating shall be free from streaks, patches, brush marks, pinholes, or colour variation. Additional coats, if found necessary to achieve a uniform finish, shall be applied by the contractor at no extra cost.The work shall include providing all materials, labour, tools, scaffolding, masking and protection to flooring, furniture, windows, doors, switch plates and other fixtures to avoid stains or damage. Stains and splashes, if any, shall be cleaned immediately. After completion of work, the site shall be cleaned and handed over in proper condition.Measurement for payment shall be taken in square metres of the finished painted surface. The quoted rate shall be inclusive of cleaning, surface preparation, putty, primer, multiple coats of distemper, scaffolding, labour, tools and all required incidentals to deliver a complete job.Make: Jotun,Asian Paints, Berger Paints, Dulux Paints or as approved by chief engineer. |
| 29 | Providing and applying two coat of primer and two coats of Texture paint, Anti-fungal, water proof, dust proof Paint on Exterior Surfaces in any pattern, at all heights of surfaces. One component waterborne 100% pure acrylic emulsion that offers protection against concrete carbonation with an R Value of min 600m and an equivalent concrete layer thickness value of min 150cm. Paint should have crack bridging property of min 1.85 mm with Solar Reflective index of min 110 and IR reflectance property. The product shall have a Volume Solids of minimum 35%The product shall be independently tested and approved for properties alike Carbon Dioxide Diffusion resistance, resistance to chloride diffusion, crack bridging and liquid water/ vapour transmission as well as SRI properties. The product can be like Jotashield WaterXtreme Topcoat of Jotun Paints or approved equivalents.Two Coats of above paint should be applied using a conventional Roller / Airless spray at the site after application and curing of applied Primer.including cleaning, preparing the surface, applying primer - scraping by sandpaper, scaffolding etc. including - (a) All surface preparation, suitable number of base coats required, primers and suitable finishing to the complete satisfaction of the Engineer in Charge, (b) Scaffolding and all leads and lifts,(c) Proper curing in between the two subsequent coats, (d) Touch ups to the paint after the scaffolding is removed, (e) All measurements for paints to be as per IS-1200. f) Minimum Guarantee of TenYears Waterproofing and Paint performance for all external paints by manufacturer .Formeasurement of painting items the area painted shall be considered without any multiplication factor for different kinds of surfaces painted. Rate shall be quoted accordingly. All painting items final finish shall be as per manufacturer\"sspecification as per acceptance of Engineerin charge /Architect. No extra payment shall be made for extra/over coat if required.Make - Asian Paint Ultima Allura Torino, Jotun Jotashield Tex Fine OR Equivalent. |
| 30 | ALUMINIUM WORKS- Providing material and labour for fixing in position frames, shutter for any type of aluminium work for any type of door, window, partition, made out of any type of aluminium sections of approved make having minimum 50 micron pure polyester powder coating of approved shade, texture & colour of approved make for all floors, all levels, all heights, all shapes, all sizes including cutting, bending, crimping, fabricating in best workmanship manner etc as per the drawing, specification and as directed by Architect or Engineer-in-Charge. Contractor shall prepare shop drawing based on concept drawing and get approved from the consultants before procurement of material. All loose material shall be approved. Mockup of one/two window shall be executed as per approved shop drawing with all hardware. Work shall carried out as per the approved shop drawings, approved mock-up and approved sample. Actual weight of installed Aluminium sections (for using fabrication without considering any wastage) shall only be measured and shall be considered for the payment. Glazing shall be paid as seperate item. Contractor shall provide guarantee for stability, water tightness etc for 12 months after defects liability period. Rate shall be inclusive of providing aluminium sections, cutting, fabrication, errection and fixing to the best workmanship manner, including1) Sheet metal screws and casted solid aluminum corner cleats fixed with external byttins with a spring for rapid and secure joint assembly for casement and sliding shutter and frame;2) Glazing clips for receiving infill panel; 3) Best quality wool pile where ever shutter touches the frame and compatible microwave cured EPDM rubber; 4) Dash Anchor fasteners of HILTI HRDUGT or equivalent for fixing the frame assembly to the RCC or masonry surfaces. Minimum 1 anchor fastener shall be used for every 600 mm length of section for stability of frame. 5) 10mm GI tie rod for connecting vertical stile at top and bottom for aluminum door shutter and 4mm thick solid aluminium corner cleat of full thickness of sectionfor connecting style and horizontal rails; 6) providing and fixing packing (rough ground) in full periphery/ at every 600mm c/c with average 6 mm thick PVC spacer/ compact sheet of width (equal to section width less 30mm for backer rod and sealant); 7) Filling the gap between wall and frame on both sides (outside and inside) with polyethylene baker rod of avg. 10 mm thickness of approved make and color and then sealing the remaining gap with neutral grade G/M (Glazed & Metal) weather silicon sealant of approved make and color. 8) Termite treated seasoned teak wood as infill material to installe hardware in door shutter and frame as and when required, etc as per directions of Engineer in charge Complete. Make:- Cardinal series, Jindal or equivalent as approved by chief engineer |
| 31 | Providing and fixing Stainless Steel Mosquito Mesh for sliding windows, including all materials, accessories, tools, labour, transportation, complete as per specifications mentioned below:The mosquito mesh shall be made from Stainless Steel of Grade SS 304, woven type, with a wire diameter between 0.30 mm and 0.36 mm. The mesh opening shall be 16×16 or 18×16 per square inch, ensuring proper ventilation and high visibility with minimum 60% airflow. The mesh shall be corrosion-resistant, rust-free, and suitable for use in humid, dusty, and coastal environments. Finish shall be in natural stainless steel.The mesh shall be fixed in a separate aluminium sliding frame if required, matching the existing window sections. Suitable aluminium sections with provision for rubber beading shall be used. The mesh shall be held firmly using EPDM or neoprene gasket to ensure tight and uniform fixing, without sagging or wrinkling. All edges of the mesh must be properly crimped and trimmed to avoid sharp edges.Sliding arrangement shall operate smoothly on rollers if a separate shutter is provided. Anti-rattle and anti-dust brush strips shall be provided at the required edges. The design shall allow easy cleaning of the mesh from inside without dismantling the frame.The installed mesh shall prevent the entry of insects, mosquitoes, and dust. It shall withstand routine cleaning through wiping or brushing, without deforming, loosening, or corroding. Mesh must maintain shape and visibility throughout its service life. Minimum lifespan shall be 10 years without rust.Installation shall be carried out with proper alignment, ensuring the frame is level and the mesh tension is uniform. No gap greater than 1 mm shall be allowed at any side.Payment shall be made on the basis of the actual finished area covered by the mesh, measured in square metres, based on clear opening dimensions.The contractor shall submit a product data sheet confirming SS 304 material, along with a physical sample of minimum 100×100 mm for approval before execution.A minimum one-year warranty shall be provided against corrosion, sagging, manufacturing defects, and installation faults.Rate shall include all materials, mesh, beading, labour, tools, fasteners, and incidental charges. |
| 32 | Providing material and labour for fixing 6mm thick Compact Sheet of any size, any shape, any color (single side, double side coloured), any texture of approved make and as per approved sample(approved by architect). Compact sheet shall be fixed in aluminium frame and shutter work with necessary cutting of sheet, provision of groove, filling of groove (both side) as per drawing & specifications including providing and fixing EPDM quality rubber/ silicon sealant/ adhesive tape/ screwing on the periphery of the sheet as per the required thickness etc. complete at all floors/ all levels/ all heights as per the drawing & directed by Engineer in charge. Cut edges of the compact sheet shall be provided with masking tape. Actual installed quantity shall be measured and paid. |
| 33 | Providing and fixing 35mm thick factory-made solid core door shutter with block board core construction, infill of solid wood strips/blocks placed edge to edge having wooden strips of pine wood or any softwood, seasoned and treated, core sandwiched between two veneers/face plywood layers on both sides. Door manufactured as per IS: 2209 / IS: 1659 and hot-pressed using BWP grade synthetic resin adhesive conforming to IS: 848. The shutter shall have continuous stiles and rails, properly pressed and bonded, with hardwood lipping/edge banding on all exposed edges, fixed using approved adhesive and machine-finished as per IS: 4020 (test requirements).The shutter shall be provided with a vision panel made of 8mm thick toughened safety glass conforming to IS: 2553 (Part 1), covering not more than 10% of the total shutter area, inserted in machine-cut openings and fixed using approved hardwood beading ensuring stability and vibration resistance. The shutter surface shall be factory-prepared to receive 1mm thick synthetic decorative laminate conforming to IS: 2046 (laminate to be paid separately).The rate shall include: complete manufacturing, block board core, stiles/rails, edge lipping, providing & fixing of toughened glass with beading, adhesive, edge finishing, and quality compliance as per IS standards.Note: Decorative laminate finish, door frame and all architectural hardware (hinges, locks, handles, door stopper, tower bolts, etc.) shall be paid separately under respective tender items. |
| 34 | Providing and fixing first class seasoned teak wood door frame of size 150 mm × 75 mm, including supplying of wooden members, cutting, sawing, planning, shaping, making corner joints, fitting, fixing, polishing, and finishing complete as directed. The wood shall be well-seasoned, kiln or air dried, free from knots, cracks, sap, decay, termite and insect infestation. The frame shall be dressed, smooth finished and machine-planed to uniform thickness.The door frame shall be provided with necessary joints such as mortise and tenon, with glue and stainless steel screws or nails, properly fitted and tightened. Suitable holdfasts made of mild steel flat (not less than 35 mm × 6 mm) shall be fixed on the sides of the frame and embedded into the wall with concrete. The frame shall have proper rebates for shutters and shall include cost of all grooves for hinges, tower bolts, stoppers, and other fittings. It shall also include provision for fixing of lock plate and other hardware cutting without any extra cost.The rate shall include the cost of teak wood, labour, cutting, jointing, holdfasts, screwing, adhesives, polishing, tools, transportation, scaffolding, and all incidental works required for proper installation. Measurement shall be taken in running meters along the outer length of the installed frame. |
| 35 | Providing and fixing 6mm thick clear toughened glass for doors, windows, partitions, glazing, full-height panels, or similar work, including all labour, materials, fixing accessories and scaffolding, complete as directed by the Engineer-in-Charge.The glass shall be 6mm thick clear float glass, heat-treated through a controlled toughening process, achieving a minimum strength of 4 to 5 times that of normal float glass. The toughened glass shall comply with IS 2553 (Part 1): Safety Glass for Architectural Use and IS 14900 (Safety Glass and Glazing System). Glass edges shall be machine-polished, smooth and free from sharpness. No chipped edges, waves, bubbles, or optical distortion shall be accepted.Glass shall be toughened at an approved factory with heat soak test wherever specified. Each piece used at site must bear the manufacturer’s permanent marking/stamp, ensuring identification of grade and make.The glass shall be installed using approved stainless-steel patch fittings, U-channel, glazing clips, EPDM rubber gaskets, aluminium channels, hinges, or spider fittings as applicable. All fixing accessories shall be non-corrosive, made of SS 304 grade minimum. For framed systems, fixing shall be with EPDM gaskets and neutral-cure silicone sealant, ensuring air-tight and water-tight joints.For door systems, suitable floor spring, door handle, lock, pivot, top patch, bottom patch and stopper shall be installed as per design. Any hardware specified separately shall be paid under respective items.Work includes cutting, edge finishing, toughening, handling, transportation, lifting, installation and cleaning. Any breakage during transportation or fixing shall be replaced by the contractor at no extra cost.Measurement shall be taken in square metres (m²) of actual installed glass area in position. Hardware, frame sections, door fittings and supports shall be measured and paid separately, wherever applicable.Approved makes for glass are Saint-Gobain, Asahi India (AIS), Pilkington, Guardian, Modi Guard, or any equivalent make approved by the Engineer-in-Charge. |
| 36 | Notes for Hardware : Supplying and fixing heavy quality fixtures and fittings for doors, windows, ventilators, partition wall, cabinets with necessaryscrews, nails, machine pins etc at all floor/ all levels/ all heights complete. Sample shall be approved by Architect before execution. As per description, SS hardware shall be of 304 grade or 316 grade as per item description and as per approved sample. The fixture & fastenings shall be provided as under :Providing material and labour for fixing single/ double action hydraulic floor spring with SS cover plate & adjustable concealed casted top pivot (two piece) and bottom strap of approved make for wooden/ aluminium doors of minimum 100kg capacity with minimum one year guarantee. Rate shall be inclusive of cutting of floor neatly, grouting the floor spring & cleaning/ polishing the floor & maintaining in good working condition until defect liability period. In case of Aluminium shutter bottom arm of floor spring & top pivot shall be firmly fixed in the aluminium members using required size of teak wood by making rabbet in the wood. The Floor Spring shall conform to EN 1154. a) Hold open having for shutter width upto 1200mm with standard spindle and cover plate. Closing force complying with EN 1154 2-4 |
| 37 | Providing & Fixing heavy qualitySS 304 heavy pivot top & bottom (pair) of approved make with SS screwsect complete as directed by engineer in charge. |
| 38 | Providing material and labour for fixing hydraulic rack and pinion door closer with standard arm (Silver finish) with screws to pivoted/ hinged door of approved make for specified door width with minimum 100kg capacity and one year guarantee. All adjustment screws face fixed. Rate shall be inclusive of fixing with using the template as per manufacturer’s specification & maintain in good working condition until defect liability period. The door closer shall conform to EN 1154 standard.a) with standard/ hold open arm with two independent closing valves and latching speed adjustable by arm without mounting back plate, Closing force complying with EN 1154 2 - 4 for up to 900 mm door shutter width |
| 39 | Providing material and labour for fixing SS 316 grade butt hinge of average 100 x 75 x 3 mm - with ball bearing of approved make as per approved sample with necessary screws etc. complete for all floor all height all level as directed by Engineer in Charge. |
| 40 | Providing material and labour for fixing set of dead lock of approved make with 50mm backseat, 20mm square for end with 72 mm centers including strike plate in satin stainless steel finish as per DIN 18251-1, grade 2 and prepared for euro profile cylinder (EPC) including strike plate and EPC length 60/70 mm standard Euro profile Pin Cylinder/ Half pin cylinder with both side key/ one side key one side knob operation with one pair of SS 316 grade Escutcheons (key hole plate) for wooden/ aluminium/ metal doors with necessary SS Phillips head screws etc complete for all floor, all level, all height as per approved sample and as directed by engineer in charge. The lock shall be with 3 keys. |
| 41 | Providing material and labour for fixing SS 316 grade push-pull pair of handle of size 200 mm long x 19mm dia made out of satin (brush) finish hollow pipe of 1.5mm thick having offset type (C or D shape)/ H-shape/ D-shape of approved makewith necessary screws etc. complete forwooden doors/ aluminium doors/ metal doors for all heights, all floors and all level as per approved sample and as directed by Engineer-in-charge. Rate shall be The length of handle should be perfect center to center as below specified. |
| 42 | Providing and Fixing SS 304 Grade Satin Finish 1.8 mm Thickness Aldrops of 16 mm dia x 250 mm including 3 nos. fixing Bracket and 1 NOS. locking bracket of approved make with necessary MS nickle Plating Boltsetc. complete for all floor, all height, all level as per approved sample and as directed by engineer in charge. |
| 43 | Providing and Fixing SS 304 Grade Satin Finish 1.8 mm Thickness Tadi of 12mm dia x 200mm including 3 nos.fixing Bracket of approved make with necessary screws, pins, bolts etc. complete for all floor, all height, all level as per approved sample and as directed by engineer in charge. |
| 44 | Providing material and labour for fixing SS 304 brush finish solid Door Stopper with magnet, fixed type, wall mounted (square/ round) of approved make with necessary screws etc. complete for all floor, all height, all level as per approved sample and as directed by engineer in charge. |
| 45 | Providing and Fixing Anti Skid Vitrified Floor Tiles (600×600mm, 10mm Thick) with work includes providing and fixing vitrified tiles of size 600×600 mm (2’×2’) and 10 mm thickness, of approved make, shade, pattern and finish, conforming to IS:15622 (Vitrified Ceramic Tiles).The tiles shall be non-slip/anti-skid type with textured or matt finish suitable for wet areas, utility spaces, ramps, balconies, terraces, toilets, corridors or areas exposed to spillage. The coefficient of friction shall meet slip-resistance requirements for floor use in wet areas as per standard practice. Tiles shall have water absorption less than 0.08%, uniform in colour, thickness and tone, and shall be free from cracks, bends, edge chips or surface defects. The type of finish such as double charge, nano polished, matt or anti-skid shall be as directed by the Engineer-in-Charge.Before fixing, the existing floor or base surface shall be cleaned properly and made free from dust, grease or loose material. Any unevenness on the surface shall be corrected by applying cement mortar in proportion 1:4 (1 cement: 4 coarse sand). In case the tiles are laid over cement concrete flooring, the surface shall be well roughened and washed before laying. Tiles fixed using 20 mm average thick cement mortar 1:4 or using approved polymer-modified tile adhesive. When laying over mortar, cement slurry shall be applied on the back of the tile at the rate of 3.3 kg per sqm to ensure proper bonding. If adhesive is used, tiles shall be fixed strictly as per manufacturer’s instructions to ensure full bedding support without voids.Tiles shall be laid in proper line and level, with joints kept uniform. After laying, tile joints shall be neatly grouted using white or coloured cement mixed with matching pigments. The surface shall be cleaned immediately after fixing to remove mortar stains, adhesive marks or grout residues. Upon completion of work, the entire flooring shall be cleaned with a soft detergent and maintained until curing is completed. Care shall be taken to avoid damage, cracking or chipping of tiles during execution.The contractor shall provide tile samples before procurement and only the approved sample shade and batch shall be used at site. The quantity shall be measured in square metre of finished work, and the rate quoted shall include the cost of tiles, adhesive or mortar, grouting material, cutting, wastage, labour charges, curing, cleaning, loading, unloading, transportation and all other incidental works required to complete the job in all respects.Make: Nitco, Simpolo, Kajaria, johnson, Rak or as approved byengineer-in-charge complete. |
| 46 | Providing material & labour for laying Vitrified tiles 8 to 10 mm thick , in required size for Skirting upto 100mm on 10mm thick cement plaster 1:3 (1-cement : 3-coarse sand) and jointed with white cement slurry including finised with flush pointing & cleaning the surface etc. complete. For SkirtingMake: Nitco, Simpolo, Kajaria,johnson, Rak oras approved byengineer-in-charge complete. |
| 47 | Providing material and labour for making Black Granite stone Counter Wash Basin of 0.60mt wide with vertical & Horizontal Support of granite stone and having bottom slab of 25mm to 30mm thick kadappa stone fixing with cement motar 1:4 (1 Cement :4fine sand) and neat cement slurry as per requirement including cutting the granite stone & providing7 fixing oval shape wash basin of 22\"\"x16\" size white colour in line & level. All exposed Edges of granite should be moulded including all accessories like pillar cock (Swan neck type), fexible inlet pipe 15mm dia, C.P. brass waste coupling 32mm, PVC Waste pipe 32mm etc. as directed by Enginner on Charge. |
| 48 | Providing material, Labour and equipments for Providing and laying integral Cement based water proofing treatment with brickbat including preparation of surface as required for treatment of roofs, balconies, terraces etc. consisting of following operations : a) Applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS 2645 and approved by Engineer in charge over the RCC Slab including adjoining walls upto 300 mm height including cleaning the surface before treatment. b) Laying brick bats with mortar using broken bricks / brick bats 25mm to 115mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer in charge over 20mm thick layer of cement mortar of mix 1:5 ( 1 cement :5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer in charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junction of walls and slabs. c) After two days of proper curing applying a second coat of cement slurry using 2.75 kg / sqm of cement admixed with water proofing compound conforming to IS : 2645 and approved by Engineer in charge.d) Finishing the surface with 20mm thick jointless cement mortar of mix 1:4 ( 1 cement : 4 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer in charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300 x 300 mm square 3 mm deep.e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test.All above operations to be done in order and as directedand specified by the Engineer in charge : Including Khurra & Gola work with average thickness of 120mm and minimum thickness at Khurra as 65 mm etc. complete as directed by Engineer in charge. |
| 49 | Providing material and labour for fixing suspended FALSE CEILING -made out of 12.0 mm (apprx.) thick Gypsum Plaster Boards of gyproc or equivalent made G.I standard section framework. -The G.I. Section frame work shall be tied to the roof and walls with the anchor fastener screws/bolts of appropriate size recommended by the manufacturer . -The boards shall be fixed to the frame work with the screws and the joints shall be flushed and finished with requisite jointing compounds paper tapes etc.-the ceiling will have 300mm wide plywood band will finish in1mm thick laminate having Burma teak texture as shown in drawing.-The surface shall be finished evenly by applying putty, sand papering, applying primer & paint of approve make and type evenly complete with designer ceiling with part ply + laminate as shown in drawing -making all necessary provision and cut outs for all electrical boards, wiring, HVAC , plumbing etc. fittings, fixtures and cleanliness as per detailed design and drawing or as directed by engineer in charge. -height of false celling will be approx. 3000mm from Floor finish level,-Price shall include any ledge, grove, offset, edging in sq.mt. only. -Length X breath of false ceiling will measured for payment. as directed by Engineer-In-Charge etc. complete. (RA) |
| 50 | Providing, fabricating, supplying and fixing Mild Steel (MS) grill for windows, complete with all materials, labour, welding, cutting, grinding, painting and installation as per drawings and instructions.The grill shall be made using mild steel sections such as flats, round bars, square bars or hollow sections. The steel used shall conform to IS 2062 Grade A or IS 1079.The grill shall be fabricated exactly as per approved architectural drawings. All joints shall be fully welded and ground smooth. Suitable MS lugs or holding brackets of minimum 12 mm thickness and 25 mm width shall be provided for fixing into the wall or window frame. Fixing shall be done with grouted bolts, anchor fasteners, or holdfasts in PCC or non-shrink grout. Welding directly to aluminium frames shall not be permitted, and only bolted connections with washers shall be allowed when grills are fixed to aluminium windows.The design must allow smooth operation of window shutters and proper cleaning without obstruction.All steel surfaces shall be cleaned properly to remove rust, oil, dust and mill scale. After cleaning, one coat of zinc chromate red oxide primer conforming to IS 2074 shall be applied. Two coats of synthetic enamel paint of approved shade conforming to IS 2932 shall then be applied. The total finished paint thickness shall be adequate to protect the steel from corrosion.The rate shall be inclusive of all materials, wastage, labour, fabrication, brackets, fasteners, grinding, primer, paint, equipment, scaffolding and transportation, and nothing extra shall be paid for these works, complete as directed by engineer-in-charge |
| 51 | Providing, fixing, and securing rainwater downpipe of 110 mm diameter made of PVC/uPVC (SWR grade) conforming to IS 13592 / IS 4985 with all required fittings such as bends, offsets, shoes, clamps, connectors, and necessary accessories. The pipe shall be fixed vertically along the wall with MS/GI clamps at suitable intervals (not exceeding 1.5 m), ensuring proper alignment and leak-free installation.All joints shall be made using SWR rubber ring joints / solvent cement, ensuring smooth flow and no seepage. The work includes making holes, cutting, trimming, finishing, and restoring surfaces where required. Disposal of debris, scaffolding, and all labour and materials needed to complete the job shall be included in the rate. |
| 52 | Providing and fixing Wash Basin vitreous china table topwash basin size 560mm x 450 mm in white colour. Like JAQUAR CNS-WHT-903 SIZZE OF 425x340x175MM with single hole for pillar tape with CP or MS brackets painted white including cutting holes and making good the same including (1) Providing and fixing SS waste couplingof 32 mm dia size half theread with 80mm height like jaquar -ALD - CHR-705for wash basin with rubber plug (2) Providing and fixing SS bottle trap with internal partition of 32mm size with 250mm &190mm long wall flange connection pipes and wall flange likejaquar ALD-769 L250X190 of approved quality with necessary fitting for wash basin (3) Providing and fixing SS Pillar cock with extention bodylike JAQUAR FUS-CHR-29021N with necessary fittings etc. complete (4) Providing and fixing SS finish Angular Stop Cock quarter turnlike Jaquar code FUS-29053 with necessary fittings (5) Providing and fixing SS finish soap dispenser with metallic bottle like Jaquar code-ACN-CHR-1135N,Towel ring -jaquar-CAN-1121BN etc. complete |
| 53 | Providing and fixing screw down bib taps of following size.(B) Brass chromium plated screws down Bib Tap. (i) 15mm dia. |
| 54 | Providing laying and jointing in true line and level 25mm dia. U.P.V.C. Pipe ( SCH- 40) for cold water including fittings as approved by Engineer In Charge. Pipe shall be fixed on the wall with the help of clamp at every two metre C/C or shall be concealed as directed including necessary fittings etc. including testing of pipe and joints and fixing the same with adhesive solvent, including cost of all materials. |
| 55 | Providing laying and jointing in true line and level 32mm dia. U.P.V.C. Pipe ( SCH- 40) for cold water including fittings as approved by Engineer In Charge. Pipe shall be fixed on the wall with the help of clamp at every two metre C/C or shall be concealed as directed including necessary fittings etc. including testing of pipe and joints and fixing the same with adhesive solvent, including cost of all materials. |
| 56 | Providing laying and jointing in true line and level 40mm dia. U.P.V.C. Pipe ( SCH- 40) for cold water including fittings as approved by Engineer In Charge. Pipe shall be fixed on the wall with the help of clamp at every two metre C/C or shall be concealed as directed including necessary fittings etc. including testing of pipe and joints and fixing the same with adhesive solvent, including cost of all materials. |
| 57 | Providing laying and jointing in true line and level 50mm dia. U.P.V.C. Pipe ( SCH- 40) for cold water including fittings as approved by Engineer In Charge. Pipe shall be fixed on the wall with the help of clamp at every two metre C/C or shall be concealed as directed including necessary fittings etc. including testing of pipe and joints and fixing the same with adhesive solvent, including cost of all materials. |
| 58 | Providing, laying and jointing in true line and level 110 diametre U.P.V.C (Type B) conforming to IS 13592-1992 with one end plain and other end socketed with rubber ring, & fittings conforming to ISI 14735-1999 of approved make for drainage system pipe line, pipe shall be jointed with EACH other with rubber lubricant, pipe shall be fixed on wall using of PVC clamp of the size 110 mm diametre x 149 mm length x 145 mm heigh at every 2000 mm center to center or shall be concealed in walls as directed including necessary fittings such as bends, shoes etc. including testing of pipes and joints and jointed with adhesive solvent cement including cost of all materials. |
| 59 | Providing erecting and fixing double coated ISI water tank of required capacity EACH with all necessary fittings and connection etc. complete on terrace |
| 60 | Point wiring for Light / Bell with2-1.5 sq.mm& earth wire of 1.5 sq.mm (Green) both are of ISI marked 1.1 KV grade FRLS PVC insulated multi strand copper wires up to 10 mtr length , in below type of pipe erectedwith 6A Modular type switch / bell push & accessories and earth continuityof following type, erected on PVC / Metallic/Wooden box, single mounting base framecovered with textured/metallic/white front plate modules erected on /in wall / ceiling as per pipe erected, with necessary Lamp holder/ceiling rose / H.D.Connector as directed.(f) with medium class Rigid PVC pipe and accessories erected concealed inwall/ceiling complete cat III |
| 61 | PointwiringforTissino/Modularsecondarylight point with 2-1.5 sq.mm & earth wire of 1.5 sq.mm (green) both are of ISI marked 1.1 KV grade FRLS PVCinsulatedmultistrandcopperwires,inbelow typeof pipetobeerected completewithearth continuityandnecessaryconnectionwithprimary lightwithaccessorieserectedon Metal/ PVC/ wooden box covered with 3 mm thick PC(Polycarbonate) / Acrylic sheetfor open / concealedwiring.withnecessaryLampholder/ ceiling rose / H.D.Connector as directed.Note:- Maximum up to 6 mtrs length, excess will be considered asMains for Secondary Point.(f) with medium class Rigid PVC pipe and accessories erected concealed inwall/ceiling complete cat III |
| 62 | Point wiring for FAN with 2-1.5 sq.mm& earth wire of1.5sq.mm(Green)bothareof.ISImarked1.1 KV GradeFRLS PVC insulated multi strand copper wiresupto10mtrlength,inbelowtypeofpipe erectedwith 6A Modular type switch and hum free EME steptypeelectronicfanregulator mounted and accessorieswithearthcontinuityoffollowing type erected on PVC / Metallic/Wooden box, single mountingbaseframecoveredwith textured/metallic/white frontplate modules erected on/inwall/ceilingasperpipeerected.with necessary ceiling rose / H.D.Connector as directed.(f) with medium class Rigid PVC pipe and accessories erected concealed inwall/ceiling complete cat III |
| 63 | Point wiring for Individual Plug with& earth wire of 1.5 sq.mm (Green) both are of ISI marked 1.1 KV grade FRLS PVC insulated multi strand copper wires up to 10 mtr length, in below type of pipe erectedcomplete with Modular type switch & 5 pin Plugerected on PVC / Metallic/Wooden box covered with appropriate front plate modules erected on / in wall / ceiling as per pipe erected with following type of accessories [II]For16APlugand16ampswitch with2-2.5 sq.mm Cu. Wire from mcb db board.(f) with medium class Rigid PVC pipe and accessories erected concealed inwall/ceiling complete cat III |
| 64 | Point wiring for Individual Plug with& earth wire of1.5sq.mm(Green)bothareofISImarked1.1 KV gradeFRLSPVCinsulatedmultistrandcopper wiresupto10mtrlength,inbelowtypeofpipe erectedcomplete with Modular type switch & 5 pin Plugerected on PVC / Metallic/Wooden box coveredwithappropriatefrontplatemodules erected on / in wall / ceiling as per pipe erected with following type of accessories. [I] For 6A Plug and 6 a switchwith 2-1.5 sq.mm Cu. Wire from nearby switchboard/mcb db board (f) with medium class Rigid PVC pipe and accessories erected concealed inwall/ceiling complete |
| 65 | providing and erecting Mains with ISI marked, 1.5KVgradeelectrolytemultistranded,annealed copper conductor with heat resistant PVC insulated conformstoIS694,IEC-227erectedinexisting pipe offollowing size (Specifically for control panel, relays, power switchgears, motor starters & control wiring)withrequiredsizeofcopperlugs,nutsand bolts if required.(f)One wire 10.00 sq. mm |
| 66 | providing and erecting Mains with ISI marked, 1.5KVgradeelectrolytemultistranded,annealed copper conductor with heat resistant PVC insulated conformstoIS694,IEC-227erectedinexisting pipe offollowing size (Specifically for control panel, relays, power switchgears, motor starters & control wiring)withrequiredsizeofcopperlugs,nutsand bolts if required.(g)One wire 16.00 sq. mm |
| 67 | providing and erecting Mains with ISI marked, 1.5KVgradeelectrolytemultistranded,annealed copper conductor with heat resistant PVC insulated conformstoIS694,IEC-227erectedinexisting pipe offollowing size (Specifically for control panel, relays, power switchgears, motor starters & control wiring)withrequiredsizeofcopperlugs,nutsand bolts if required.(h)One wire 25.00 sq. mm |
| 68 | providing and erecting Mains with ISI marked, 1.5KVgradeelectrolytemultistranded,annealed copper conductor with heat resistant PVC insulated conformstoIS694,IEC-227erectedinexisting pipe offollowing size (Specifically for control panel, relays, power switchgears, motor starters & control wiring)withrequiredsizeofcopperlugs,nutsand bolts if required.(i)One wire 35.00 sq. mm |
| 69 | ProvidinganderectingMainswith1.1KVgrade FRLSPVCinsulatedISImarkedstrandedCopper conductor wire in following typeof pipetobe erectedconcealedin/flushedonwall/ceiling,with1.5 sq. mm copper conductor FRLS PVC insulated stranded wire of green colour for earth continuity offollowing size. (A) With medium class Rigid PVC pipe and accessories (a) 2 wire 1.5 sq. mm |
| 70 | Providing & erecting PVC Corrugated Flexible Conduit with required nos. of coupling, PVC bushes, Check-nuts etc. complete of followingsizes.(2) 25 mm |
| 71 | Providing and erecting Sheet Steel powder coated MCB distribution board - flush / surface mountedfittedwithbusbar,neutrallink,earth barandDINrail,ConformstoIS8623-1&3, IEC 61439-1 & 3 without MCB to house appropriate nos. ofMCBs.(The DBsshould be usedofsamecompanyofMCBtobeused) suitable for(A) single phase incoming and horizontal single phase outgoing(b) sheet steel double door (IP-43) (iii)8 way |
| 72 | Providing & erecting Approved make Power Saving 50 Watt Ceiling Fan with double ball bearing ISI mark with Condenser 230 volt A.C. 50 Hz 1200 mm sweep complete having3blades with aluminium blades with , canopy & 30 cm. down rod erected with earthing.(Make shall be approved by Engineer in charge)) |
| 73 | Supplyinganderecting19/20mm.nominal bore Medium Class M.S. Pipe down rod erected duly painted for fan complete with proper insulation without leakage and earthing. |
| 74 | Supplying& erecting fan hook box of 10 mmM.S. round bar bounded to the RCC bars up to 50mm length each side and pierced through a16GaugeM.S.box/HeavyDutyPVCbox complete erected concealed in Ceiling with necessary finishing. |
| 75 | Providing2.5mm.thicklaminatedacrylicsheetto cover the fan hook or Fan box. |
| 76 | Supplying & erecting approved make low noise decorativeexhaustfanhavingsquareframe ABS body with inbuilt lowers & square frame.200mm with 1350RPM Cat.II |
| 77 | Supplying and erecting LED indoor fittings with LEDsofwattage0.2Wattto0.5Watt assembledonsingleMCPCB,withhousing usedasaheatsinkshallbemadeofthick sheet Steel conforming to IS: 513/CRCA/aluminiumpressurediecast powder coated and high U.V. & corrosion resistance withdiffuser housedinaluminium casted body with company mark/name 160Vto270V,PowerFactormorethan0.95, THD < 15 %, CCT3000 K to 6500K, Luminaire efficacy> 85 lumens/watt , LED driver efficiency > 85 % ( fitting required LM-79 & LM-80 Certificates)(NOTE:Belowdescriptionhave shown ranges of Wattage capacity of LED fittings.TheEngineerinchargemayselectany wattage capacity between the ranges shown.)(A) Square/ Circular shaped Surface/Recessed Mount Downlight with provision for spring loaded mounting clips complete.IP20 (iii) 16-20 watts, Surge-2 KV cat - III |
| 78 | Point wiring for on board Looped Plug with 6A Modular type switch & 5 pin socket erected on PVC / Metallic/Wooden box, single mounting base frame covered with textured / metallic/whitefront plate modules erectedon/ in wall / ceiling with following type accessories Cat. III |
| 79 | ProvidinganderectingApprovedmakeFour pole moulded case circuit breaker having breaking capacity ICU of 25 KA. at 415 V,havingnormalcurrentratingupto25Ato 100A.withFixedthermal&magneticrelease suitable to work on A.C. supply 50 c/s. with all internal connections, spreader tinned copper & completeerectedinexisting16G.M.S. housing. |
| 80 | Providing and erecting Approved make Four pole moulded case circuit breaker having breaking capacity ICU of 35 KA. at 415 V. having normal current rating125A. with Fixed thermal & magnetic release suitable to work on A.C.supply 50 c/s. with all internal connections, spreader tinned copper & complete erected in existing 16 G.M.S. housing. |
| 81 | Providing and erecting Approved make Four polemoulded case circuit breaker having breaking capacity ICU of 35 KA. at 415 V. having Normal current rating 200A.with variable Thermal & magnetic release suitable to work on A.C.supply 50 c/s. with all internal connections, spreader tinned copper & complete erected in existing 16 G.M.S.housing |
| 82 | Providing and erecting Approved make Four pole moulded case circuit breaker having breaking capacity ICU of 50 KAand above at 415 Vhaving Normal current rating400A. with variable Thermal & magnetic release suitable to work on A.C.supply 50 c/s. With all internal connections, spreader tinned copper & complete erected in existing 16 G.M.S. housing.Cat III |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail