| 1 | Dismantling of old brick tiles or terracing tiles,single layer on roofs complete all as specified and directed by Engr-in-charge. |
| 2 | Demolition of existing mud in roofs of any thickness including plastering and leaping, whether full thickness removed or only a part there of, and removing of mud as directed by Engr-in-charge. NOTE- (1) demolished mud should be removed from the site everyday no stack can be made. (2) Mud that is recovered from the roof should be removed by bags not direcltly thrown from roof. |
| 3 | Removing excavated material exc 1.5Km and not exc 5.00 km outside of MOD Land and depositing where directed at a level n exc 1.5m above the starting point complete all as specified and directed by Engr-in-Charge. |
| 4 | Roughening the surfaces of old concrete roof surfaces by picking, sweeping clean and washing down with water to remove dust etc including removal of old treatment of any description and removing the debris to a distance of n.exc 50 m away from plinth protection. |
| 5 | M&L for cutting out cracks to V-section in existing roofs or terrace cleaning out and filling solidly with a hot mixture of bitumen and clean dry sand in cement mortar 1:1 (by weight) complete all as specified and directed by Engr-in-charge. |
| 6 | M&L for PCC 1:2:4, type B1 by using 20mm graded stone aggregate in Providing, cement concrete in roof kerbs or mud stops, rounded or chamfered on edges complete all as specified and directed by Engr-in-charge. |
| 7 | M&L for applying cement slurry over existing roof surface @ 3 Kg/Sqm complete all as specified and directed. |
| 8 | M&L for 10mm thick rendering in cement mortar 1:4 (mixed with WPC @ 3% by weight of cement) to brick/concrete wall and roof surfaces finished even & smooth (without using extra cement) with water proofing compound at the rate of 3% by weight of cement or as per the manufacturer’s instructions complete all as specified and directed by Engr-in-charge. Note: WPC shall be measured and paid for separately |
| 9 | Supply only water proofing compound all as specified and directed. |
| 10 | M&L for APP based polymeric membrane one side plain and one side rough finish minimum weighting 3 kg/Sqm and minimum 3mm thick reinforced with polyester non woven fabric (wt not less than 150 gms/sqm) over one coat of 85/25 bitumen @1.2 kg/sqm and paste the membrane with torching method and again apply a coat of 85/25 bitumen @ 1.2 kg/sqm at overlapping joints |
| 11 | S & F for Heat Resistant Terrace Tiles (300 mm x 300 mm x 9 mm) with SRI (solar refractive index) > 78, solar reflection > 0.70 and initial emittance > 0.75 on waterproof and sloped surface of terrace, laid on 20 mm thick cement sand mortar in the ratio of 1:4 (1 cement : 4 coarse sand) and grouting the joints with mix of white cement & marble powder in ratio of 1:1, including rubbing and polishing of the surface up to 3 cuts complete, including providing skirting up to 150 mm height along the parapet walls in the same manner. |
| 12 | Dismantling of stone slab and tiles of any description or thickness on steps, jambs, pillars, walls, cooking platform, floors, aprons, skirting etc laid bedded and pointed in cement mortar complete all as specified and directed |
| 13 | M & L for16-20mm thick granite table rubbed and polished in wall lining, , fixed with 15 mm thick backing coat in cement mortar 1:3 complete all as specifed and directed. |
| 14 | M & L for16-20mm thick granite table rubbed and polished AS in cooking platforms, fixed with 20 mm thick screed bed in cement mortar 1:4 complete all as specifed and directed. |
| 15 | M&L for Green marble work 18 to 20mm thick (table rubbed and polished) in steps,jambs,window cills, and like including including 15mm thick screed bed in CM 1:4 and pointing in white cement (1:2) using marble dust with admixture of pigment to match with marble shadeincluding rounded edges with shade of granitecomplete all as specified and directed. |
| 16 | M&L for cleaning the sides rolling shutter shafts guide channel and greasing of moving parts of rolling and straightening rolling and replacement of bolts nuts etc as required for smooth functioning of shutters and taking out existing rolling shutters if required and refixing the same in original position complete all as specified (opening of shutter exc 2.00 m and not exc 3.50 m and area exc 6.00 sqm and n.exc 9.00 sqm all as specified) |
| 17 | S&F in repair steel rolling shutters, thickness of lath 1 mm, with out ball bearing, top cover, anchoring rod and hasp & staple, erected in position where required (in patches or whole), complete push pull or manual type complete as directed |
| 18 | S&F steel rolling shutter with ball bearing as specifird incl top cover ,anchoring rod,hasp and staple and one shop coat of primer,erected in position as indicated , complete gear operated type with bevel gear box and cranked handle (1.25 mm thickness of laths) complete all as specified and directed. |
| 19 | Dismantling A.C/Fibresheet corrugated or semi corrugated sheet in roof coverings. |
| 20 | S&F Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm of an colour having tensile strength of 550Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified |
| 21 | S&F stainless steel drapery curtain rods gold or antique silver 25mm nominal dia and minimum wall thickness 1.20mm of SS-304 grade of approved brackets design as approved fixed in brick/ concrete wall with same finished knobs/latto on each end of curtain rod including taking down old pelmet, complete all as specified and directed. |
| 22 | S & F in repair Steel work in tubular trusses including special shapedwasher etc. complete using ERW or induction butt welded tubes conforming to I. S.1161- 1979 grade St.-240 complete all as specified |
| 23 | S & F 0.56 mm Plain, Aluminium sheeting, Alloy 31000 H4 in ridges, hips, valley gutter, drip and straight flashing (length and girth as fixed) complete all as specified and directed by Eng-in-charge. |
| 24 | Dismantling of wrought iron orMild Steelwork of any description complete all as specified and directed by EIC complete all as specified and directed by Eng-in-charge. |
| 25 | S&F roof trusses Fe 410-W (Gde E-250) quality -A (framed), trussed, purling, wind tie,crane gntries and rail and fastening and heavy bracket framing (Beam, tee, angle, channel or flat sections )including distance pieces, cleats etc complete all as specified and as directed by Engr-in-Charge. |
| 26 | M&L for preparation of new or previously untreated steel surfaces of any description, over 10cm width or girth, not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer complete all as specified and directed by Engr-in-Charge. |
| 27 | M&L for 5mm thick rendering in cement mortar 1:3 finished even and smoothe surface without using extra cement on ceiling, chajjain building etc incl taking down incl two coats of white wash complete all as specified and directed by Engineer-in-Charge Note rate quoted up to G+5 bldg including scaffolding complete all as specified and directed. |
| 28 | M&L for rendering 10mm thickon fair faces of brick work or concrete surfaces in CM 1 : 4 mixedfinished even and fair including taking down old plaster complete all as specified. Note rate quoted up to G+5 bldg including scaffolding complete all as specified and directed. |
| 29 | M&L Providing and applying cement base plaster of Paris putty of 1 mm thickness over plastered surface to prepare the surface even and smooth complete all as directed.Note rate quoted up to G+5 bldg including scaffolding complete all as specified and directed. Note rate quoted up to G+5 bldg including scaffolding complete all as specified and directed. |
| 30 | M&L for preparation of newly plaster surface of wall / Ceiling surfaceapplyingtwo coats of weather proofing exterior acrylic emulsion paint by spray gun/ spray machineincl one coat of primerincluding scaffoldingcomplete all asspecified and all as directed by Engr- in-charge.Note :- 1. Stage for prepration of surfaces shall be got approved from GE before applying the finishes.2. Material shall be procured from manufacturer and work shall be got executed through authorised applicator. Note rate quoted up to G+5 bldg including scaffolding complete all as specified and directed. |
| 31 | M& L for preparation of newly plastered surface and applyingtwocoats of Oil Bound Distemper over a coat of primer onwall surfaces to give an even and smooth surfaceall as specified and directed. Note rate quoted up to G+5 bldg including scaffolding complete all as specified and directed. |
| 32 | Cutting shrubs wild growth, plants not exc 30 cm girth grown on permanent structures and removingsame growth right from roots and stopping the recurrence by injecting herbicide Glyphosphate 4+solution (04 % concentrate) into plant root to eliminate further growth. Application shall be as per manufactureres intructions. The disturbed area shall be repaired with PCC (1:2:4) Type B0 mix and surface finished even and smooth in cm 1:4 incl applying two coats of matching finish i.e. Building is not less than 50 nos .complete all as specified and directed at site Note rate quoted up to G+5 bldg including scaffolding complete all as specified and directed. |
| 33 | Demolition of cement concrete (reinforced) of any description and in any position not otherwise specifically provided for (reinforcement cut as required to facilitate demolition) by using diamond saw blade cutting machine without damaging adjacent RCC structures not otherwiseincluding removal of rubbish outside complex ( MOD land), complete all as specified. Note rate quoted up to G+5 bldg including scaffolding complete all as specified and directed. |
| 34 | S&F of min 4mm thick prefabricated Factory made FRP chajja of fibre ways brand or equivalent in required size, colour and design made by Resin Transfer Moulding (RTM) machine technology, resulting in voids free compact laminate in single piece having smooth gradual slope curvature of easy drainage of water fixed to wall having silicon sealant joint in between chajja and wall so as to prevent any leeage/seepage through joints complete all as specified and directed by Engr-in-charge Note rate quoted up to G+5 bldg including scaffolding complete all as specified and directed. |
| 35 | M & L for painting previously untreated steel and iron surfaces of any description, over 10cm in width or girth,not otherwise described with one coats of synthetic enamel paint complete all as directed. |
| 36 | M&L for preparation of old decoreated/undecoreatedexternal wall / Ceilingapplyingtwo coats of weather proofing exterior acrylic emulsion paint by spray gun/ spray machine up to 5 storey bldg complete all asspecified and all as directed by Engr- in-charge.Note :- 1. Stage for prepration of surfaces shall be got approved from GE before applying the finishes.2. Material shall be procured from manufacturer and work shall be got executed through authorised applicator. Note rate quoted up to G+5 bldg including scaffolding complete all as specified and directed. |
| 37 | Dismantling water tanks of capacity exceeding 500 litres but not exceeding 1000 litres complete. |
| 38 | S&F 1000 ltr capacity rotational moulded triple layered polyethylene water storage tanks (cylindrical vertical with closed top) white colour hoisted and fixed in position all as specified. |
| 39 | S & Fin repairs of 20mm ball brass valve high pressure with polyethlene float flynut complet screwed with iron pipe or brass ferrule and fixed in repair all as spd. |
| 40 | S & Fin repairs of 20mm bore Gun metal globe or gate valves,with iron wheel head,screwed both ends for iron pipe and fixed all as specified and directed.Note rate quoted up to G+5 bldg including scaffolding complete all as specified and directed. |
| 41 | Demolition and breaking up drain pipesalt glazed ware, AC, PVC/CI or reinforced concret pipes internal dia of pipe 100mm /75mm complete all as specified and directed by Engr-in- chargeNote rate quoted up to G+5 bldg including scaffolding complete all as specified and directed. |
| 42 | S&F 75mm dia cast iron soil waste pipe fixed to wall and gap between wall and pipe will be filled by PCC 1:2:4 complete all as specified and directed by Engr-in- chargeNote rate quoted up to G+5 bldg including scaffolding complete all as specified and directed. |
| 43 | S&F 100mm dia cast iron soil waste pipe fixed towall and gap between wall and pipe will be filled by PCC 1:2:4 complete all as specified and directed by Engr-in- chargeNote rate quoted up to G+5 bldg including scaffolding complete all as specified and directed. |
| 44 | S&F CI bend 75mm tee elbow socket complete all as specified and directed by Enr in charge.Note rate quoted up to G+5 bldg including scaffolding complete all as specified and directed. |
| 45 | S&F CI bend 100mm tee elbow socket complete all as specified and directed by Enr in charge.Note rate quoted up to G+5 bldg including scaffolding complete all as specified and directed. |
| 46 | Taking up or down steel water tubing and connections including cleaning for refixing or removal to store of 20 mm bore.Note rate quoted up to G+5 bldg including scaffolding complete all as specified and directed. |
| 47 | Taking up or down 15mm bore GI tubing and connections, including cleaning for re-fixing or removal to store, complete all as specified and directed.Note rate quoted up to G+5 bldg including scaffolding complete all as specified and directed. |
| 48 | S&F GI water tubing medium grade 20mm bore with all fittings and fixed complete to walls and ceiling or laid in floors Note rate quoted up to G+5 bldg including scaffolding complete all as specified and directed. |
| 49 | S&F GI water tubing medium grade 15mm bore with all fittingsand fixed complete to walls and ceiling or laid in floors Note rate quoted up to G+5 bldg including scaffolding complete all as specified and directed. |
| 50 | Complete removal of existing treatment on wall (any number of layers ) by scarping with steel scrapersor any other mean including filling depressions of scrapped surface with putty and preparation of surface with primer for further treatment and M&L for two coats of distemperoil emulsion white or tinted complete all as specified and directed by Engr-in -ChargeNote rate quoted up to G+5 bldg including scaffolding complete all as specified and directed. |