| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 13-02-2026 | Corrigendum 1 | Technical Bid | 10-03-2026 |
| Sl. No. | Item Description |
| 1 | Schedule 1 - Part A - KPWD SR 2024-25 Items - Civil |
| 2 | Earth work in surface excavation by mechanical means for lowering & leveling the ground for all works other than foundation in all kinds of soils & upto depth not exceeding 300mm as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenances required to complete the work. |
| 3 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work |
| 4 | In all kinds of soils Depth upto 3 m-In all kinds of soils-(Consider 70% of total excavation) |
| 5 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications,including shoring, strutting, barricadachinery & other appurtenaces required to complete the work In ordinary/soft rock without blasting depth exceeding 1.5m, but not exceeding 3m. Consider 30% Qty as Soft Rock/Ordinary rock |
| 6 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m |
| 7 | Providing and injecting chemical emulsion for Pre-constructionalAnti-Termite Treatment, creating continuous chemical barrier under and around the column pits, walls, trenches, basement excavation, top surface of the plinth filling, junction of wall and floor, along the external perimeter of building, expansion joints, over the top surface of consolidated earth on which apron is to be laid, surrounding of pipes and conduits with Chlorpyriphos 20% E.C. / Lindane 20% E.C. @ 3.19 l/m2 including cost of chemical, diluting in water to one percent concentration, labour, usage charges of machinery, complete as perspecifications. (Page no.5 item 4.1P.W.D. SR-2021-22 vollume -II) |
| 8 | Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. |
| 9 | Mix 1:4:8( M5) Using 40 mm nominal size graded crushed coarse aggregates-Consider for Formwork 3% (all other types ) |
| 10 | Providing and laying in position plain cement concrete for levelling course for all works in foundation.The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost including formwork) |
| 11 | Mix 1:3:6 (M10) Using 20 mm nominal size graded crushed coarse aggregates |
| 12 | Below Basement Floor - Consider for Formwork 60% (RCC Beams & Lintels of building) |
| 13 | Ground floor - Consider for Formwork 60% (RCC Beams & Lintels of building) |
| 14 | Providing and laying in position Cement Concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications |
| 15 | M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates- sub structure RCC works |
| 16 | Providing and laying in Cement Concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/ basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compactedusing needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery,curing and all other appurtenances required to complete the work as per technical specifications. |
| 17 | M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates |
| 18 | For RCC retaining wall (base)- Consider for Formwork 8% (Isolated) |
| 19 | For RCC retaining wall (base)- Consider for formwork 10% (Earth retaining structutres) |
| 20 | For Column concrete upto Plinth Bottom - Consider for Formwork 70% (Columns) |
| 21 | Plinth beam concrete- Consider for Formwork 50% (Pllinth beam) |
| 22 | For ramp - consider for Formwork 5% (road medians, traffic seperator, divider etc) |
| 23 | For RCC drain in basement - Consider for Formwork 35% (for cement concrete drains) |
| 24 | Basement floor - Cosider for Formwork 70% (Columns) |
| 25 | Basement floor - Consider for Formwork 60% (for beam & lintels of building) |
| 26 | Window Chejja concrete - consider for formwork 45% (for chejjas) |
| 27 | Roof for UG sump - Consider for Formwork 50% (roof) |
| 28 | For RCC lift - Consider for Formwork 10% (Vertical sections) |
| 29 | Staircase (1 no)- Consider for Formwork 50% |
| 30 | Providing Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) upto plinth level with - Cement mortar 1:6 (1 cement : 6 coarse sand) |
| 31 | Providing Size Stone masonry with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand)- above ground upto plinth bottom. |
| 32 | Providing and laying in position Reinforced cement concrete M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) |
| 33 | M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates |
| 34 | Ground Floor - Consider for Formwork 70% (For Columns) |
| 35 | Ground Floor -Consider for Formwork 60% (RCC Beams and Lintels of building) |
| 36 | Ground Floor -Consider for Formwork 45% (chejja) |
| 37 | Ground Floor -Consider for Formwork 50% (roof) |
| 38 | Staircase Type-1 (2 nos) - Consider for Formwork 50% |
| 39 | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. |
| 40 | Basement and Floor |
| 41 | Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. |
| 42 | Basement Floor |
| 43 | Ground Floor |
| 44 | Providing and constructing load bearing wall with Solid Concrete blocks of size 400x100x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications |
| 45 | Ground floor |
| 46 | Providing, laying & fixing cement base, precast, pre polished cement concrete, designer tiles 25mm thick conforming to IS 1237 heavy duty tiles for flooring, treads of steps and landing, laid on a bed of 12mm thick cement mortar 1:3 mis finished with flush pointing using white cement, including cost of materials, mortar, including cutting, griding the edge to half/full round wherever required, labour, curing complete as per specification. |
| 47 | Providing 12 mm cement plaster with cement mortar 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.- Ground floor |
| 48 | Basement Floor |
| 49 | Ground Floor |
| 50 | Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster with cement mortar 1:6 (1 cement : 6 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. |
| 51 | Basement Floor |
| 52 | Ground Floor |
| 53 | Providing and applying white cement based putty of averagethickness 1 mm, of approved brand and manufacturer, over theplastered wall surface to prepare the surface even and smoothcomplete as per specifications and as per directions of Engineer incharge.(Page no.50 item 8.51P.W.D. SR-2021-22 vollume -II) |
| 54 | Providing and laying water proofing treatment to the Roof with PU basedsingle component elastomeric pure polyurethane based coating onNew terrace/Chajjas/Sunken portion of WC:Bathroom, cold applied PUwaterproofing membrane that is highly elastic with elongation greaterthan 400% and tensile strength greater than 2MPa as per ASTM D412. The waterproofing membrane to be applied in 2coats @ 1.6kg per m2to achieve final DFT (dry film thickness) of 1mm including prime coat of epoxy primer @150 g per m2 and protection with 120gsm Geo-textileover the waterproofing membrane. The finished cost to include surfacepreparation, making coving at Junction, Bore Packing, treatment of construction joints completely as per specification & with a 10 yearswarranty on product & work from certified manufacturers as per the direction of the Engineer In charge.(Page no 133item 15.1 P.W.D. SR-2021-22 vollume -II) - GF toilets |
| 55 | UGT/OHT (inside) waterproofing with Anti-microbial Coating Providing and Applying two component, water-based food grade epoxy resin coating on inside surface of Potable water tank having anti-algae, antifungal, Non-toxic, hygiene cum damp-proof coating Certified by CFTRI as per 21 CFR 175 – 300 of US – FDA, having mixing Ratio (Base: Hardener: Water) – 1:1:1 to be applied @ 0.35 Kg/m2 in 2 coats. Ensure that this coating is applied over the protective plaster, and that Item No. 4 is completed across the entire surface prior to applying the protective plaster. The Waterproofing material shall have Specific Gravity: 1.2, Water vapor permeance: 244.48 g/m2/24 hrs, as per IS 7809/Pt 2/1977, Adhesion strength: 2 N/mm2 as per ASTM D 4541: 02. The finished cost to include surface preparation completely as per specification - UG sump |
| 56 | Retaining wall/ UG tank wall (outside) Waterproofing with SBS Membrane Providing and laying water proofing treatment to the Retaining wall, water retaining structures outside with fully bonded 1.6mm Thick SBS modified self-adhesive, cross laminated HDPE Valero lining waterproofing membrane, conforming to IS 16471:2017 Type A, requirements of UG waterproofing structures, The SBS membrane shall have Mass per Unit Area > 1.8 Kg/m2 as per ASTM D 5147, Puncture resistance > 200 N as per ASTM E 154, Elongation > 180% as per ASTM D 412-06, Tensile Strength > 4 Mpa as per ASTM D 412- 06, Tear resistance > 20 N/mm as per ASTM D 4073, Hydrostatic pressure > 50M as per DIN 1048. The lap with HDPE membrane shall be 100mm treated with TS tape. followed by the installation of 8-10mm THK polyethylene dimpled drain board having compressive strength > 400kN/m2 (as per ISO 25619-2). The finished cost includes surface preparation, making coving and a coat of solvent based bituminous primer @ 0.25l/m2 on entire surface before laying membrane completely as per specification- RCC Retaining wall |
| 57 | Providing and fixing pressed steel door frames conforming to IS: 4351, manufactured from commercial mild steel sheet of 1.60 mm thickness, including hinges, jamb, lock jamb, bead and if required angle threshold of mild steel angle of section 50x25 mm, or base ties of 1.60 mm, pressed mild steel welded or rigidly fixed together by mechanical means, including M.S. pressed butt hinges 2.5 mm thick with mortar guards, lock strike-plate and shock absorbers as specified and applying a coat of approved steel primer after pre-treatment of the surface as directed by Engineer- in-charge: Profile C Fixing with adjustable lugs with split end tail to each jamb including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. |
| 58 | Ground floor |
| 59 | Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internalframe with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturercomplete as per spcification. |
| 60 | -do- 35 mm thick one side teak and one side commercial- Ground Floor |
| 61 | Providing and fixing Fiber Glass Reinforced plastic (FRP) Door Frames of cross- section 90 mm x 45 mm having single rebate of 32 mm x 15 mm to receive shutter of 30 mm thickness. The laminate shall be moulded with fire resistant grade unsaturated polyester resin and chopped mat. Door frame laminate shall be 2mm thick and shall be filled with suitable wooden block in all the three legs. The frame shall be covered with fiber glass from all sides. M.S. stay shall be provided at the bottom to steady the frame |
| 62 | Providing and fixing to existing door frames Glass Fibre Reinforced Plastic (FRP) panelled door shutter of required colour and approved brand and manufacture, made with fire - retardant grade unsaturated polyester resin, moulded to 3 mm thick FRP laminate for forming hollow rails and styles, with wooden frame and suitable blocks of seasoned wood inside at required places for fixing of fittings, cast monolithically with 5 mm thick FRP laminate for panels conforming to IS: 14856, including fixing to frames. - 30mm thick |
| 63 | Providing and fixing bright finished brass butt hinges with necessary screws etc. complete :125x85x5.5 mm (heavy type) - GF |
| 64 | Providing and fixing bright finished brass tower bolts (barrel type) with necessary screws etc. complete :250x10mm-GF |
| 65 | Providing and fixing bright finished brass handles with screws etc. complete:Brass handles 125 mm with plate 175x32 mm-GF |
| 66 | “Providing and fixing cold rolled prepainted steel windows of IS standards, made out of 0.6mm thick deep drawing quality galvanised on both sides 120gms/sq.mtr. Primer coat upto 5 microns with thermosetting epoxy resin and finish painted with a polyester based paint 20 microns thick. The size of profiles is approximately 46x52mm for external frames, 46x46mm section for shutters, 46x70mm section for centre mullion/transom and 18x31mm section is for fixing glasses. The section should be cut to length joint mitred and assembling by means of corner brackets made out of cold rolled cold annealed strips of 1.2mm thick duly galvanised and fixed with nickle plated self taping screws. The shutters are provided with approved quality of fixtures like handles made out of zamac alloy die cast and powder coated, receiver made out of glass filled nylone and hinges made out of CRCA powder coated. 4mm thick glass should be fixed with EPDM gaskets. Guard bars fabricated out of 10mm square bright bars shall be fixed horizontally at 125mm C/C by rivetting to the external frame. The above frames are fixed to the concrete / masonry walls by means of self expanding screws.”-with 4mm float glass and without guard bars. |
| 67 | Basement and Ground floor |
| 68 | Providing & fixing of 2-track x 2-panel sliding windows made out of multi chambered UPVC (Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 50mm width x 42mmheight with reinforcement of 1mm thickness and Sash with overall size of 31mm X 57mm with Gi reinforcement of 1mm for the frame and 1.5 mm for the sash. Coextruded Glazing bead for fixing of glass shall be of size 21.5mm x 9.5 mm. Windows shall be provided with 5mm plain float glass, standard hardware& single point locking system with touch lock. Wall thickness of frame & sash shall be of 1.8+-0.2 mm. Maximum possible size – 1519mm x 1519mm. (The cost is inclusive of all fixtures and separate charges for minor T&P\"s shall not be made)- Basement and Ground Floor |
| 69 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding (Page no.85item 11.34A P.W.D. SR-2021-22 vollume -II)Revised rate w .e f. from 07-07-2022-Basement and Ground Floor |
| 70 | Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.)including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge-Basement and Ground Floor |
| 71 | Providing and laying Vitrified tiles with thickness 9-10 mm in different sizes with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joint with white cement & matching pigments etc. complete-Size of Tile 600x600 mm |
| 72 | Providing and laying Polished Sadarahalli Grey Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 20 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. |
| 73 | Basement Floor |
| 74 | Ground Floor and Staircase-type-1(2 nos) |
| 75 | Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including pointing the joints with white cement and matching pigments etc., complete. |
| 76 | Ground floor |
| 77 | Providing skirting, dadooing, rises of steps with colour glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications |
| 78 | Ground floor |
| 79 | Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two coat applied @ 0.90 ltr/10 m² over an under coat of primer applied @ 0.80 ltr/10 m² of approved brand and manufacture including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. |
| 80 | Painting wood work with Deluxe Multi Surface Paint of required shade. Two coat applied @ 0.90L/10 m² over an under coat of primer applied @0.75 L/10 m² of approved brand and manufacture to give an even shade including preparing the surface after thorougly cleaning oil, grease, dirtand foreign matter, sand papering and knotting , cost of materials, labourcomplete as per specifications and as per directions of Engineer-in-charge. |
| 81 | Polishing in high gloss/matt finish melamine clear polish on wood work in required color/wooden shade texture with following process in thesequence as detailed below:1. The surface to be polished is rubbed with sand paper 80/120 no. and then with sand paper of 160/180 no. 2. Applying two coats of sealer with spray gun and allowing sufficient drying time for 1st coat and 2nd coat is allowed to dry for 8 to 12 hrs.3. On drying of sealer coat, wet rubbing with emery cloth of finer grading with ample water to remove excess sealer layer andmake the surface further smooth after this wet rubbing, then surface is applied with special grade melamine fillers to fill all thesmall and big holes/grooves etc. Filler coat to be allowed to dry for 4 to 6 hrs on which again a light wet rubbing is done this surface isfurther allowed to dry for 12 hrs. |
| 82 | Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications: Two coats applied on walls @ 1.25 ltr/10 m² over and including one coat of Special primer applied @ 0.75 ltr /10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge-Basement floor and ground floor |
| 83 | Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade: New work (Two coats applied @ 1.67 ltr/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specificationsand as per directions of Engineer-in-charge- Basement and Ground Floor |
| 84 | Providing and laying 100mm thick pre-cast cover slabs over Road side drains / utility ducts / Rain water harvesting pit of width not exceeding 1000 mm using M20 concrete reinforced with TMT bars Fe 550 @ 6kg/ m2, slabs jointed in CM 1:3 proportion and nicely finished Including providing holes in the Cover slabs wherever necessary for easy drainage of surface water including of labour, materials, scaffolding, usage of machinery, curing, lead and lift charges etc, Complete. |
| 85 | Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. Using flats 30x6mm for diagonal braces and central cross piece including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge - ground floor |
| 86 | Providing and fixing brass stop cock of approved quality :15 mm nominal bore- ground floor |
| 87 | Providing and fixing PTMT pillar cock of approved quality and colour.15 mm nominal bore, 125 mm long foam flow, weighing not less than 120 g |
| 88 | Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required:White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests |
| 89 | Providing and fixing white vitreous china pedestal type water closet(European type) with seat and lid, 10 litre low level white vitreous chinaflushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mmflush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required W.C. pan with ISI marked white solid plastic seat and lid - Ground floor and First Floor |
| 90 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require:White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar taps - Ground floor and first floor |
| 91 | 600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 g |
| 92 | Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. |
| 93 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal sibility for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work |
| 94 | 25mm nominal OD pipes |
| 95 | 32mm nominal OD pipes |
| 96 | 40 mm nominal OD pipes |
| 97 | Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end) : |
| 98 | 50 mm nominal bore |
| 99 | Providing and fixing unplasticised PVC connection pipe with brass unions : |
| 100 | 20 mm nominal bore |
| 101 | KSRB 13-11.1 : Providing and placing on terrace,(All floor levels )polyethylene water storagetank IS :12701 Marked , with cover and suitable locking arrangement and marking necessarry holes for inlet , outlet and over flow pipes but with out fitting andthe base suuport for tank |
| 102 | PVC pipes of 8 kg/cm2 for 140 mm (3.097) |
| 103 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, , (i) Single socketed pipes. |
| 104 | Earth work excavation by manual means for drains,canals, waste weir draft, approach channels, key trench, foundation of Bridges and such similar works, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, excavated surface leveled and sides neatly dressed disposing off or leveling the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage & other appurtenances required to complete the work. |
| 105 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes,having thermal stability for hot & cold water supply including all CPVCplain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work 150 mm nominal dia Pipes |
| 106 | Constructing brick masonry chamber of internal dimension 600x600mm and depth of 600mm (inner dimensions) with modular bricks of CD 75 in cement mortar 1:6, bed concrete 150mm thick with 1:3:6, plastering 12 mm thick with cement mortar 1:4, CC 1:2:4 coping 75mm thk for fixing CI cover & frame etc. excluding the cost of CI frame and cover |
| 107 | Providing and fixing 100 mm sand cast Iron grating for gully trap - For building |
| 108 | Providing and fixing PTMT grating of approved quality and colour 125 mm nominal dia |
| 109 | Geophysical investigation at site for sinking borewells for Providing drinking water to the habitation either through the Hand Pump MWS or P.W.S.S, by vertical electrical sounding by adopting Venner or Schlumbergers\"s method, including reconnaissance survey of geological formation. Geophysical investigation of existing ground water in the vicinity, its quality, quantity and acceptability of the users, indicating the location of the site, recommended depth of casing pipe required to seal the top unconsolidated formation including an extra depth of 1.0 metre in consolidated formation for proper seating of casing pipe, depth of drilling required to cover full depth of aquifer proposed to be tapped, probable yield and other information required including transportation of instruments and accessories to work site, engaging technical personal and labour required etc. NOTE: 1) Additional rate on item 1&2 is allowed for drilling in over burden and fixing Casing pipes beyond 20 M (for fixing Casing pipes only) a) Above 20 M and upto 30 M - 15%, b) Above 30 M - 30% (Measurement of overburden is restricted to thedepth of casing pipe fixed excluding initial depth of 20M and projection above ground level). 2) A sum of Rs. 100/- is to be deducted for Dry Borewell towards yield test Etc complete |
| 110 | Sinking of Borewell of 165mm dia clear using super fast hydraulic rig of capacity 300 PSIG & above 1100 CMF & above in all strata including over burdern upto 20 m. Fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of rig and supporting vehicle, crew charges and cost of consumables etc., complete including yield testing at the final depth with a minimum working of compressor for one hour (Excluding cost of casing pipes, collars, cap etc., complete ) (Above 450m of drilling add 10% for every 50m depth) 12.1.1 Borewell depth o |
| 111 | 0-50mtr |
| 112 | 50-100mtr |
| 113 | 100-150mtr |
| 114 | 150-200mtr |
| 115 | Supply of ISI mark 175mm nominal bore,plain and steel casing pipe grade of steel Fe 410 of wall thickness conforming to IS 4270-2001 andlatest ammendments, electrical resistance welded steel tubes, material and conforming to IS 1387-1993 and manufactured by basic open hearth electric or basic oxygen process in random length of 5-7m both ends.threaded conforming to IS 554-1985 one end fixed with socket conforming to IS 4270-2001 and the other end with screwed pipes all shall be responsibaly free from defects. The tubes shall be responsible straight end should be with ISI marking weighing 25.10kg/m.prices include Collar-Medium duty. |
| 116 | Providing PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc |
| 117 | Providing, laying and jointing HDPE pipes of specified grade and conforming to IS 4984-2016 with latest ammendments and conveying to work site including loading and unloading at both destinations and rolling and lowering into trenches, laying true to line and jointing of pipes and specials with electrofusion welding, giving hydraulic test as per relevant ISS with all lead and lifts including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excation, testing and commissioning. The rate is exclusive of required specials and fittings wherever necessary like saddle Tee, stub ends, flanged sets, bedns, reducers etc. complete (Contractor will make his own arrangements for procuring water for testing) etc. complete. NOTE: Upto 110mm dia Coil shall be used. For :HDPE PE 80 PN 6.0-HDPE Grade PE80-PN6.0, 63mm dia |
| 118 | Providing Submersible Pump Set of 150mm dia suitable for bore well and confirming to IS 8034-2000;3Phase, SS Bowl & Impeller with Low volt Motor as per specifications, to work site as per necessary ammendments and instructions of engineer incharge of work-13.13.6 5.00 HP - 90 LPM @ 110 m = 15 STG Outlet Dia - 2.00\" |
| 119 | Supply and delivery at site Brand new best make PVC insulated cable of Flat 3 core (sheathed) of nominal cross sectional area as per IS 694-1990 with ISI Mark and as per its latest amendments- 1x3x6 sqm |
| 120 | Supply, installing,testing and commissioning COMMON control panel consisting of the following INCOMING:1 No set of Phase indicating lamps with SFU of suitable rating 1 No, Analog Ammeter, 1 No Analog Voltmeter 1ni with Phase selector switch, Isolating switch OUTGOING for Main Electrical Pump: 1 No. MCB 1 No. DOL of S/D Starter suitable for respective HP 1 No. Electrcal Protection Like single Phase preventor, under voltage over Volage, under current over current & dry run protection suitable for the pump described above 1 no Indoor type NOTE: 1) DOL- Direct Online Starter 2) S-D- Star Delta Starter etc. complete |
| 121 | Earthing: Providing and fixing and wiring earth electrode for grounding circuits IC cutouts and other equipments on the meter board in the pit. The pits should be filled up with equal proportion of salt and charcoal 150mm around the pipe to complete depth. The connection from the pipe to the conduits etc. is to established through GI wire of sizes as per clause 7.3.3 of IS 732 using 12mm bolts, nuts, washers and check nuts, the pipe shall have 16 through holes of 12mm dia. |
| 122 | Supply and delivery at site of brand new best make gate valve as per IS 778/1984 with ISI Mark and as perlatest amedment-size 50mm |
| 123 | Supply and delivery at site of brand new best make non-return valve as per IS 778/1984 with ISI Mark and as per its latest amendments- size 50mm |
| 124 | Schedule -1 - Part - B - I -KPWD SR 2023-24 Items - Electrical |
| 125 | Supplying and wiring adopting loop system in existing PVC Conduit / casing cappingusing 2X1.5Sqmm (Phase & Neutral)& 1X1.0 sqmm (Earth Wire) FRLS multi strand PVC insulated copper wire (Confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block complete for each outlet. |
| 126 | Short point up to 3 Mtr from tapping point to out let via switch box |
| 127 | Medium point above 3 Mtr up to 6 Mtr from tapping point to out let via switch box |
| 128 | Long point above 6 Mtr up to 10 Mtr from tapping point to out let via switch box |
| 129 | Two out let in a row, above 3 Mtr up to 6 Mtr from tapping point to out let via switches |
| 130 | Supplying and Flush mounting powder coated/Galvanized metal Box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in brick/stone/ C.C Wal |
| 131 | 1-2 Way |
| 132 | 3 Way |
| 133 | 4 Way |
| 134 | 6 Way |
| 135 | 8 Way |
| 136 | 10-12 Way |
| 137 | Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs,Machine/NF screws etc., complete. |
| 138 | 1 to 2 Module |
| 139 | 3 Module |
| 140 | 4 Module |
| 141 | 6 Module |
| 142 | 8 Module |
| 143 | 10-12 Module |
| 144 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293 |
| 145 | 6 Amps one way Switch |
| 146 | 6 A Two way Switch. |
| 147 | 6 Amps Three way socket. |
| 148 | Stepped Fan Regulator Two Module |
| 149 | 32 AmpsDP switch |
| 150 | 6/16 Amps universal socket |
| 151 | TV / Telephone Socket |
| 152 | RJ 45 /I.O Outlet Cat-6 |
| 153 | Supplying And Fixing Metal Fan Box with Round Hook. |
| 154 | Supplying heavy gauge PVC conduit pipe......mm dia..........mm thick confirming to IS2509 with suitable size bends,metal/PVC Junction boxes,adhesive paste etc.,and running before concreting the slab.The conduit should be tied to there inforcement rods by using binding wires and un used ways of junction boxes and pipe ends should be covered using PVC end enclosures,run with 18 SWG GI fish wire wherever necessary |
| 155 | 19/20 mm dia 2 mm thick |
| 156 | 25 mm dia 2 mm thick |
| 157 | 32 mm dia 2.5mm thick |
| 158 | Supplying heavy gauge PVC Conduit Pipe....dia.......mm thick with suitable size bends,metal junction boxes adhesive paste etc.,by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering upto the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary. |
| 159 | 19/20 mm dia 2 mm thick |
| 160 | 25 mm dia 2 mm thick |
| 161 | 32 mm dia 2.5mm thick |
| 162 | Wiring for lighting/power circuit using one ofFRLS PVC insulated 1100v grade, multistrand Copper with low conductor resistance single core wire in open or concealed system of wiring with specified IS-694:1990 & confirming to latest amendments |
| 163 | 1.5 sqmm |
| 164 | 2.5 sqmm |
| 165 | 4 sqmm |
| 166 | 6 sqmm |
| 167 | 10 sqmm |
| 168 | Supplying and drawing Flexible Multi core Cable manufacture d with electrolytic grade flexible copper with low conductor confirming to IS8130-1984and (Virgin)PVC insulation sheathed suitable for working voltage upto 1100 Volts as per IS-694:1990 |
| 169 | 2C x 1.5 mm2 |
| 170 | 2C x 2.5 mm2 |
| 171 | Supplying and drawing 3 core flat PVC sheathed sub mersible pump cable manufactured with electrolytic grade copper with flexible copper with low resistance conductor confirming to 13:8130-1984 and virgin grade PVC insulation and powder coating extruded PVC sheathed suitable for working voltage upto 1100 Volts as per IS-694:1990. |
| 172 | 3C x 2.5 mm2 |
| 173 | Distribution boards : Supplying and fixing regular MCB distribution boards on wall / wood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB\"s single phase / 3 phase / single door with powder coated painting. Made out of 14 SWG MS enclosure. |
| 174 | II - Double Door |
| 175 | 4 Way SP & N |
| 176 | 12 Way SP & N |
| 177 | III - Double Door |
| 178 | 4 Way TP&N |
| 179 | 6 Way TP&N |
| 180 | Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and \"C\" Type curve , indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. |
| 181 | 6-32 Amps SP |
| 182 | 6-32 Amps DP |
| 183 | 40 Amps DP |
| 184 | 6-32Amps TPN |
| 185 | 50-63Amps TPN |
| 186 | Supplying, fixingand wiring Residual Current breaker (RCCB) 240/450V up to 300mA sensitivity on existing wood/ panel board. |
| 187 | 32-40 Amps 2 pole |
| 188 | 32-40 Amps 4 pole |
| 189 | 63 A 4 pole |
| 190 | Supplying of ......feet- PVC Batten with integrated LED tube .....WwithhighqualitydiffuserwithLifeof25000burning hours&70%lumenmaintenancewithCRI>80.Power Input: 220-240V @ 50/60Hz & Power factor >0.9 along with CE approved.2 years Warranty against any manufacturing defect working under standard electrical condition. |
| 191 | LED light fighting 1 X 4\" - 20/22 w |
| 192 | LED light fitting 1 x 4\" - 36/40 W |
| 193 | Supply of round/square recess/surface mounted rolling type LED Down light with...... WGU 10 LED Lamp Rib Fabricated from diecasta luminium with white powder coated pre wired to mains connector & has swivelling unit of aluminium die casteye ball & LED Lamp position retained by circular wire spring, with Life of 25000 burning hours & 70%lumen maintenance with CRI>80. Power Input:220-240V@50/60 Hz & Power factor>0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition |
| 194 | LED square or round down light 15-18W |
| 195 | Supplying of recess mounting non integral type........LED w luminaire comprising of pressure decast/extruded aluminium housing, with spring loaded false ceiling clamps, Power LED swith CCT 6500 degree K,CRI>70%. efficacy>100 lumen per W,120 degree beam spread, life>25000 burning hours and Compliance to IS10322/IEC60598, LM79& LM80. The lamp compartment is enclosed with antiglare opal diffuser which enhances the lighting level LED s are driven by HF electronic driver integrated in a separate control gear assembly., with PF>0.95, power loss should<5%of lamp Wage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM79. The operating input voltage should be between 130 to 275 V. BIS Approved and Tested by NABL / CPRI ac credited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition. |
| 196 | LED modular down light 1\"x1\" 24 W |
| 197 | LED modular down light 2\"x2\" 36 W |
| 198 | Supply of LED flood light luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate/clearglass material, delivering superior light output Rated life Burning Hrs 50000 hr @ Lumen Maintenance of 70%, CCT>5500K, IP66 optical and electric alcompartment & impact resistance of complete luminaire>IK08. Power Factor>0.9 with mains, Surge Protection -Min 5 KV along with Over voltage/Overload, short circuit / miss -wiring protection. Compatible for pole mauling with outer dia of 40 mm to 50 mm. Universal Voltage driver to operate wide voltage range from 100 V to 270 V 50/60 Hz application. Compliance to IS10322/IEC60598, LM79& LM80 Adherence with RoHS. UL approved MCPCB. Top access streetlight with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with....... W System Power consumption. LED Efficiency>1301m/w, nominalCRI>75. Luminaire manufacturer should have in -house facility accredited by NABL/CPRI & any Government certified agency & Design & Development facility certified by ISO9001:2008. Housing with supplier word mark/name shall be Engraved/Embossing on the die cast housing/Bodypart Warranty of 2 Years against any manufacturing defect working understandard electrical conditions as mentioned above should be given by LED manufacturer & Cree/Nichia/Lumileds/Osram make LED Source. |
| 199 | LED Floodlight 70W |
| 200 | Supply of LED Streetlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate material, delivering superior light output Rated life Burning Hrs 50000 hr @ Lumen Maintenance of 70%, maximum light intensity should be between 60 degrees to 70 degrees. CCT > 5500K, IP66 optical and electrical compartment & impact resistance of complete luminaire > IK08. Power Factor >0.9 with mains, Surge Protection- Min 5KV along with Over voltage/ Overload, short circuit/ miss-wiring protection. Compatible for pole mounting with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100V to 270V 50/60Hz application. Compliance to IS 10322/IEC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with ........W System Power consumption. LED Efficiency>1301m/w, nominal CRI >75. Luminaire manufacturer should have in-house facility accredited by NABL/CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008. Housing with supplier word mark /name shall be Engraved / Embossing on the die cast housing/ Body part. Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer & Cree/Nichia/ Lumileds/Osrammake LED Source. |
| 201 | LED Streetlight 90 W |
| 202 | Supplyingandfixing of230volts 20/40 watts Fluorescent Lamp holder |
| 203 | Supplying&fixingretrofittype-PL-LEDLampW LEDlinearsourcewithCCT6500degreeK,CRI>70%. efficacy>80lumenperwatt,life>25000burninghours andCompliancetoIS10322/IEC60598,LM79&LM 80. The LED are driven by HF electronic driver integrated in the system, with PF > 0.95, power loss should < 5% of lamp wattage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 volts.Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition. |
| 204 | 8-9 Watts |
| 205 | Supplying capacitor type ceiling fan complete with down rod blades, shackle, canopies etc., for operation on 230 volts, 50 cycles.Single phase AC supply conforming to ISS-374-1979 and with double ball bearing system. |
| 206 | 48\" Sweep (1200mm) Regular model |
| 207 | Supplying wall mounting fan suitable to operate at single -phase 230 v AC. supply. |
| 208 | 300 mm Sweep |
| 209 | Supplying of 1440rpm heavy dutyexhaust fan with bracket blades suitable to operate on 230V 50Hz, AC Supply complete. |
| 210 | 12\" Sweep(300mm) |
| 211 | 2 mm thick perforated cable GI tray with on existing MS angle support using necessary GI bolts/nuts and washer or welding as required. |
| 212 | 150 x 50 mm |
| 213 | Supplying and Fixing of........mm dia class A GI pipe bracket upto2 ms long bent at suitable angle and fixing to this bracket street light fitting of all capacities to GI or GIorrailor RCC pole/wall using suitable clamps,bolts,and nuts and wiring using suitable capacity wires. |
| 214 | Using 32mm dia G.I.Pipe |
| 215 | Fixing halogen/metal halide /SVL/IL/LED floodlight fitting over existing pole / wall ceiling including clamps, bolts, nuts and wiring using suitable capacity wires. |
| 216 | Fixing all types and all capacities of fluorescent / false ceiling / spot light / CFL / LED fittings indoor on the wall / ceiling/ rafters / girders using23/0.0076” twin twisted PVC insulated wires, required Nos of round blocks and clamps |
| 217 | On wall / ceiling / Rafter / Girders |
| 218 | Fixing a ceiling / Wall mounting fan of all capacities and all types to the existing \"S\" hook with fan regulator to the existing board together with supplying and fixing5 amps. ceiling rose, necessary length of 23 / 0.0076 inch PVC insulated twin twisted copper wire and wiring. |
| 219 | Fixing one exhaust fan in the nitch already left in the wall with bolts and nuts and 5 amps. Ceiling rose with sufficient length of 23 / 0.0076 inch PVC insulated twin core wire. |
| 220 | Supplying and drawing UTP-CAT 6E LAN cable. |
| 221 | Supplying and drawing PVC flexible one pair telephone unarmoured tinned copper cable. |
| 222 | 2Pair |
| 223 | 5Pair |
| 224 | Supplying & Fixing of switch mounting rack with power manager & Cable manager. |
| 225 | 6U with 450mm depth |
| 226 | 9U with 450mm depth |
| 227 | Supplying fixingof Network Switches |
| 228 | 48 port 10/100/1000 Switch |
| 229 | 24 port 10/100/1000 Switch |
| 230 | Supplying & Fixing of Patch Panel for LAN cabling |
| 231 | 48 Port 10/100/1000 patch panel |
| 232 | 24 Port 10/100/1000 patch panel |
| 233 | Supplying & Fixing of ...ms Cat 6 Patch Cable |
| 234 | 1 m |
| 235 | 2 m |
| 236 | Supplyingfixingandwiringearthelectrodeforgrounding of lifts, transformers, DG sets etc. using 40mm dia 2.9mm thick2.5mtrlongGIpipewithGIfunnelwithmeshand suitable size reducer fixed on the top of the earth electrode. The funnel should be enclosed in a CC chamber of 400x400x400mm with a cast iron cover. The earth electrode shall have staggered holes of 12mm dia and the electrode should be covered 150mmall-round with alternate layers of salt and charcoal from the bottom of theCC chamber. The connection from the electrode is to be established through GI strip using GI bolts and nuts. |
| 237 | GI/Copper strips for grounding connections, using necessary fixing materials as required. |
| 238 | 25 X 3 mm GI strip |
| 239 | 600 x 600 x 3 mm Copper Plate |
| 240 | Providing 6kg Fire Extinguisher Mono Ammonium Phosphate Powder 90, Stored Pressure Type, Pressure Gauge, Gross Weight 9.40 Kg, empty weight 3.4 Kg, Can Height 480MM, Diameter 160MM, Discharge Time less than 13 Sees, Controllable discharge mechanism (Squeeze grip with easy snap safety seal), Range minimum 4 meters, applicable on Class A,B, C and electrically started Fire, A Rating 3A, B Rating 21B, Can construction : Deep drawn & Co., Mig welded, valve Construciton : Forging and Mechining, Internal Coating of Can: Epoxy powder coating, External Coating of Can: Epoxy Polyster power coating, Sheet metal thickness: 1.60MM, 5 years Warranty with instalert system with Superior quality EPDM Rubber Hosepipe etc., including cost of materials, labour, usage charges of machinery complete as per specifications. complete IS 15683 and CE Approved |
| 241 | Providing 4.5Kg C02 gas valve type Fire Extinugisher, Tro lley Mounted, Easy Weight Management used Unused Mechanism, Gross Weight 19.1 Kg. empty Weight 14.6 Kg. Can Height 860MM Diameter 140MM, Discharge Time less than13 Sees,Controllable discharge mechanism, Applicable on Class 8&C Fire, 8 Rating 138, Can Constuction : Hot spinning/Forging, Valve Construction : Forging & Machining, Internal Coating of Can : Not Applicable, External coating of Can : Spray Painting, Sheet metal thickness : 4.5M M lSI Approved, 1YearWarranty.with instalert system with Superior quality EPDM Rubber Hosepipe etc., including cost of materials, labour, usage charges of machinery complete as per specifications. complete |
| 242 | Providing 9 Ltr Water type Fire Extinugisher, Stored Pressure Type, Pressur Gauge,Gross Weight 15.1kg. empty weight 6.1kg Can Height 615MM, Diameter 175 MM,Discharge Time less than 120 Secs, Controllable discharge mechanism (Squeeze grip with easy snap safety seal), Range minimum 6 Meters, applicable on Class A Fire, A Rating 3A, Can Construction; Deep drawn & CO, Mig welded, Valve Construction: Forging & Machining, Internal Coating of Can : Epoxy Powder coating,External Coating of Can : Epoxy Polyster Powder coating, Sheet metal thickness: 2.OM M, lS 15683 and CE Approved. Years Warranty with instalert system with Superior quality EPDM Rubber Hosepipe etc., including cost of materials, labour,usage charges of machinery complete as per specifications. complete |
| 243 | Supplying of four bucket stand along with buckets. Complete |
| 244 | Supplying of Hand gloves. Complete |
| 245 | Supplying of First aid box. Complete |
| 246 | Supplying of SAFTEY MASK. Complete |
| 247 | Supplying of FIRST AID CHART with lamination. Complete |
| 248 | Supplying and installation of RUBBER MAT 1 mtr x 1 mtr -1O mm thick. Complete including cost of materials, labour, usage charges of machinery complete as per specifications. |
| 249 | Schedule -1 - Part - B - II - ESCOM SR 2023-24 Items - Electrical |
| 250 | 1.1 KV , XLPE or Heat resistivity PVC insulated, PVC exutruted inner seath Armoured LTUG Cable as per IS-1544(Part -1) or 7098 part - 1, Armouring strip thickness and resistivity as per IS-3975 - |
| 251 | 16 Sqmm, 4 Core, (11 GI Strips - 4 x 0.8 mm) |
| 252 | 185 Sqmm, 3.5 Core, (28 GI Strips - 4 x 0.8 mm) |
| 253 | 95 Sqmm, 3.5 Core, (21 GI Strips - 4 x 0.8 mm) |
| 254 | Laying of cable in Existing Trench/GI pipe/Stone Ware/ RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff - |
| 255 | 2.5 to 25 Sqmm |
| 256 | 35 to 95 Sqmm |
| 257 | 120 to 240 Sqmm |
| 258 | Heavy Duty Copper Terminal Long Barrel |
| 259 | 25 Sqmm Copper Terminal, Apprx Wt: 26 Gm |
| 260 | 95 Sqmm Copper Terminal, Apprx Wt: 58 Gm |
| 261 | 185 Sqmm Copper Terminal, Apprx Wt: 158 Gm |
| 262 | Brass Cable Gland |
| 263 | 25 mm |
| 264 | 32 mm |
| 265 | 45 mm |
| 266 | Caution / Danger Board |
| 267 | Fixing Danger Board |
| 268 | Schedule -1 - Part - B - III - DSR 2025 - Electrical Works |
| 269 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. |
| 270 | Upto 35 sq. mm |
| 271 | Above 35 sq. mm and upto 95 sq. mm |
| 272 | Above 95 sq. mm and upto 185 sq. mm |
| 273 | Laying of one number additional PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground in the same trench in one tier horizontal formation including excavation, sand cushioning, protective covering and refilling the trench etc as required. |
| 274 | Upto 35 sq. mm |
| 275 | Above 35 sq. mm and upto 95 sq. mm |
| 276 | Above 95 sq. mm and upto 185 sq. mm |
| 277 | Supplying and fixing cable route marker with 10 cm X 10 cm X 5 mm thick G.I. plate with inscription there on, bolted /welded to 35 mm X 35 mm X 6 mm angle iron, 60 cm long and fixing the same in ground as required. |
| 278 | Schedule - 1 - Part B - IV - Market Rate Items - Electrical |
| 279 | Supply, installation, testing and commissioning of LT Main power panel made up of 16 SWG sheet steel, floor mounting type with all normal practice like derusting, phosphating, powder coated, prime coats and finish paints of approvedcolour, with all leads and lift and as per specifications and directed by the Engineer incharge Incomer:250 A 4P Change over switch - 1 no. 250 A 3P + NL 35 KA MCCB - 1 no.LED type panel indication lamps RYB colour -1 set 0 - 500V Voltmeter with Selector Switch - 1 no0 - 300A Ammeter with Selector Switch - 1 noCT operated Ammeter and Volt meter. ELR with CBCT - 1 no. Bus bar chambers with 250 A Al Bushbars (Colour code shall be followed strictly for all phases)Out going: 125A 3P + NL 25KA MCCB - 4 nos.100A 3P + NL 16KA MCCB - 2 nos.63A 3P + NL 16KA MCCB - 2 Nos. Provide RHOM for all MCCB\"s Capacitor Bank of 15 KVAR:Each Bank consisting of 32A 3P MCB and 5 KVAR Capacitor switching duty contactors, with ON / OFF push buttons & ON indication lamps complete - 3 Banks |
| 280 | Supply, installation, testing and commissioning of LT Sub power panel made up of 16 SWG sheet steel, floor mounting type with all normal practice like derusting, phosphating, powder coated, prime coats and finish paints of approvedcolour, with all leads and lift and as per specifications and directed by the Engineer incharge Incomer : 125 A TPN 35KA MCCB - 1 No.LED type panel indication lamps RYB colour 1 - set 0 - 500V Voltmeter with Selector Switch - 1 no0 - 300A Ammeter with Selector Switch - 1 no CT operated Ammeter and Volt meter.Bus bar chambers with 125 A Bushbars (Colour code shall be followed strictly for all phases)Out going : 63 A TPN MCB - 12 nos. 40 A TPN MCB - 6 Nos.Provide terminal connectors for MCB\"sProvide RHOM for all MCCB\"s |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail