| Sl. No. | Item Description |
| 1 | Earth work in excavation by mechanical means (hydraulic excavator) in trenches for foundations, drains, pipes, cables etc. (not exceeding 1.5 m in width) and for shafts, wells, cesspits and the like not exceeding 10 sqm on plan, including dressing of sides and ramming of bottoms lift upto 1.5 m, including getting out excavated earth and disposal of surplus excavated earth as directed, within a lead of 50 metres:All kinds of Soils |
| 2 | Providing,Laying, spreading and compacting stone aggregate of specified sizes in uniform thickness, hand picking, rolling watering and compactingIncluding all carriages and lifts upto the site of work complete job |
| 3 | Providing and laying in position specified grade of cement concrete excluding the cost of centering and , shuttering , All work up to plinth level 1:4:8 (1cement: 4 coarse sand : 8 graded stone aggregate |
| 4 | Providing,Laying, spreading and compacting RBM/stone aggregate of specified sizes in uniform thickness, Ramming/compacting watering and Including all carriages and lifts upto the site of work complete job |
| 5 | Providing and laying in position specified grade of cement concrete including curing but excluding the cost of centering, shuttering, finishing and einforcement. All works upto plinth level 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) |
| 6 | Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-incharge. Note: - Cement in this item is @ 330 kg/ cum. Excess or less cement used as per design mix is content considered payable or recoverable separately.All works upto plinth level |
| 7 | Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-incharge. Note: - Cement in this item is @ 330 kg/ cum. Excess or less cement used as per design mix is content considered payable or recoverable separately.All works above plinth level upto floor V level |
| 8 | Centering and shuttering including strutting, propping etc. and removal of form work for: foundation |
| 9 | Walls (any thickness) including attached pilasters, buttresses, plinth and string courses etc |
| 10 | Lintel, beams, plinth beams, girders, bressumers and cantilevers. |
| 11 | Columns, pillars, piers, abutments, posts and struts |
| 12 | Suspended floors, roofs, landings, balconies and access platforms. |
| 13 | Stairs (excluding landings) except spiral staircases. |
| 14 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete Thermo-Mechanically Treated bars of grade Fe-500D or more |
| 15 | Providing wood work in frames of doors, windows, clerestory windows andother frames, wrought framed and fixed in position with hold fast lugs or withdash fasteners of required dia and length (hold fast lugs or with dash fasteners shall be paid for separately): Imported Wood |
| 16 | Providing 40x5mm flat Iron hold fast 50 Cm long incld: fixing to frame with 10mm diameter bolts, nuts and wooden plugs and embeddings in cement conc: block 30x10x15Cm 1:3:6 mix 1 Cement:3 coarse sand 6 graded stone agg: 20mm Nom: size) etc complete. Incld: all carriages complete |
| 17 | Providing and fixing glazed shutters for doors, windows and clerestory windows using 4mm thick float glass panes including ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws.Imported Wood (35mm Thickness of Shutter) |
| 18 | Providing and fixing wire gauze shutters using galvanized M.S. wire gauze of average width for aperture 1.4 mm in both directions with wire of dia. 0.63 mm for doors, windows and clerestory windows with ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws as per direction of Engineer-in-charge : Imported Kiln Dried (35mm Thickness of Shutter) |
| 19 | Providing and fixing 35mm thick ISI marked flush door shutters non decorative type solid core of block board construction with frame of hard wood all around 20 mm thick & well matched teak 3 ply veneering with vertical grains or cross bands & face veneeres on both faces incl. bright finished ISI marked butt hines with necesaary screw imported kail wood |
| 20 | Brick work with common burnt clay (non-modular) bricks of class designation 7.5 in foundation and plinth including curing in :Cement mortar 1:6 ( 1 cement : 6 coarse sand) , Extra for brick work with common burnt clay bricks/cement concrete bricks in superstructure above plinth level upto floor five level |
| 21 | Providing & fixing of 4 mm thick float glass in fixed panes with budloo wooden beading of required width fixed with nails complete (glass panes to be measured in fitted and finished form) |
| 22 | Painting wood work with deluxe multi surface paint of required shade. Two or more coats applied @ 0.90litre/10sqm over an under coat of primer applied @ 0.75litre/10sqm of approved brand and manufacture |
| 23 | 12 mm cement plaster of mix 1:6 ( 1cement;6 coarse sand ) |
| 24 | Providing and applying white cement based putty of specified thickness, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete 2 mm thick |
| 25 | Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade on New work (two or more coats) over and including priming coat with water thinnable cement primer |
| 26 | Finishing walls with acrylic smooth exterior paint of required shade on New work (Two or more coats applied @ 1.67 liter/10sqm over and including priming coat of exterior primer applied @ 2.20kg/10sqm) |
| 27 | Providing and fixing gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations, of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels:(Area of slab over 0.5 sqm) Granite of any colour or shade 16 mm |
| 28 | Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting , fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished welded type tubes |
| 29 | Providing Hi-Rib roofing sheet including vertical / curved surface fixed with polymer coated J or L hooks, bolts and nuts 8 mm diameter with bitumen and G.I. limpet washers( incl ridges hips) 0.5 mm thick |
| 30 | P/F of 12mm thick T&G planks made of imported wood (New zealand pine or equivalent) for roof soffits & Ceiling on wood work in false ceiling, partitions sawn and putup in position in budloo wood (Ceiling Joists). including cost of necessary adhesive & cost of nails etc. with necessary cornice of required size complete job. incl cost of nails / screws all complete as approved by Engineer-in-charge (including cost of all material, leads, lifts and carriages etc upto site of work complete).Soffits |
| 31 | Providing and fixing plained eaves boarding.300x40 mm (nominal size)Ornamental Imported Wood |
| 32 | Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) over 75mm bed of dry brick ballast 40mm nominal size well rammed and consolidated and grouted with fine sand including finishing the top smooth and curing complete |
| 33 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622 of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1cement :4 coarse sand) including grouting the joints with white cement and matching pigments etc. complete Size of tile 600x600 mm |
| 34 | Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS : 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer- in-Charge, in skirting, risers of steps and dados over 12 mm thick bed of cement mortar 1:3 ( 1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3 kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. |
| 35 | Providing and laying Ceramic glazed floor tiles 300x300 mm (thicknessto be specified by the manufacturers) of 1st quality conforming to IS: 15622 of approved make, laid on 20 mm thick bed of cement mortar 1: 4 ( 1 cement : 4 coarse sand) including pointing the joints with white cement and matching pigment etc., complete. In all colours, shades, except White, Ivory, Fume Red Brown |
| 36 | Providing & laying water proofing treatment to vertical and horizontal surfaces of depressed portions of W.C., kitchen & the like consisting of: (i) Ist course of applying cement slurry @ 4.4 kg/sqm mixed with water proofing compound conforming to IS 2645 in recommended proportions including rounding off junction of vertical and horizontal surface. (ii) IInd course of 20 mm cement plaster 1:3 (1 cement: 3 coarse sand) mixed with water proofing compound in recommended proportion including rounding off junction of vertical and horizontal surface.(iii) IIIrd course of applying blown or residual bitumen applied hot at 1.7 kg. Per sqm of area.(iv) IVth course of 400 micron thick PVC sheet. (Overlaps at joints of PVC sheet should be 100 mm wide and pasted to each other with bitumen @ 1.7 kg/sqm). |
| 37 | Providing and fixing stainless steel (Grade 304) railing made of Hollow tubes channels, plates etc. including welding ,grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete ,including fixing the railingn with necessary accessories and stainless steel dash fasteners, stainless steel bolts etc. of required size, on the top of the floor or the side of waist slab with suitable arrangement including king posts of required pattern as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.).\"3.5 kg/Rm |
| 38 | Kota stone slab flooring 25 mm thick over 20mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing, polishing and curing complete with base of cement mortar 1:4 (1 cement : 4 coarse sand |
| 39 | Kota stone slab 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm ( average) thick cement mortar 1:3 (1 cement:3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing, polishing and curing complete. |
| 40 | Providing and fixing of Hardware fittings (Allys) as per approved |
| 41 | 100mm Handles |
| 42 | 150mm Handles |
| 43 | 100mm Tower Bolts |
| 44 | 150mm Tower bolts |
| 45 | Stay Hooks |
| 46 | L-Drop 8 Inch with link lock, |
| 47 | Plumbing and sanitary |
| 48 | Providing and Fixing disposal/vent pipes(PVC) of type B class including all fittings |
| 49 | 160mm dia PVC Pipe |
| 50 | 110 mm dia PVC pipe |
| 51 | 75mm dia PVC pipe |
| 52 | PVC Floor Trap with jali |
| 53 | Providing and fixing 3 layer PP-R (Poly propylene Random copolymer) pipes conforming to IS: 15801, UV stabilized and anti-microbial fusion welded, having thermal stability for hot and cold water supply including all PP-R plain and brass threaded Polypropylene random fittings. This includes testing of joints complete as per direction of Engineer-in-charge. Internal work Concealed fixing the pipe with clamps at 1.00 meter spacing including cutting chases and making good the wall etc |
| 54 | PN-16 pipe 16mm OD (SDDR-7.4) |
| 55 | PN-16 pipe 20mm OD (SDDR-7.4) |
| 56 | PN-16 pipe 25mm OD (SDDR-7.4) |
| 57 | PN-16 pipe 32mm OD (SDDR-7.4) |
| 58 | Providing and fixing 3 layer PP-R (Poly propylene Random copolymer) pipes conforming to IS: 15801, UV stabilized and anti-microbial fusion welded, having thermal stability for hot and cold water supply including all PP-R plain and brass threaded Polypropylene random fittings. This includes testing of joints complete as per direction of Engineer-in-charge.External work including trenching, refilling etc |
| 59 | PN-16 pipe, 40mm OD (SDR-7.4). |
| 60 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank ISI 12701 marked with cover and suitable locking arrangement & making necesssary holes for inlet outlet & overflow pipes (triple layer) |
| 61 | Providing and fixing 15mm nominal borre C.P brass long nose bib cock of approved quality conforming to IS standard & weighing not less than 810g |
| 62 | Providing and fixing 15mm nominal bore C.P angle valve for basin mixer and geyser points of approved quality conforming to IS 8931 |
| 63 | Providing and fixing 15mm nominal bore of standard back type C.P brass close hole basin mixer pillar tap of approve qaility and make weighing not less than 1.970 Kg |
| 64 | P/F of C.P brass double lever wall mixer with concealed shower of approved qaulity and make as approved by Engineer Incharge |
| 65 | Providing and fixing whilte vitreous china water closet (European typeW.C Pan) with seat and lid , 10 litre low level white PVC flushing cistern including flush pipe with manually controled device (Handle lever) conforming to IS 7231 , with all fittings and fixtures complete including cutting and making good the walls and floor wherever required pan with ISI marked white solid plastic seat and lid |
| 66 | Providing and fixing water closet squatting pan (Indian Type W.C Pan) with 100mm sand cost iron P or S trap, 10 ltrs low lewel PVC flushing cistern including flush pipe (Hindware make Cat No. 20070/ Kerovit make Cat No. 606) Manually controlled device (Handle lever) conforming to IS : 7231, with all fitting and fixture complete including cutting and making good the wall and floows wherever required. Orissa Pan white viterous china pan of size 580x440mm with integral type footrests. |
| 67 | Providing & fixing of white vitreous china under counter oval wash basin/circular basin (Hindware 10080 / Kerovit model No. 206 & 207) with CP brass waste assembly, CP cast brass bottle trap with extension piece (Jaquar Cat No. 769B + Parko1535, KA870001 or approved equivalent), 450mm long CP copper connections pipes (Jaquar Cat No. 803B or Parko 1535 or approved equivalent), wall flanges and rubber adapters for waste connection complete including CI/MS brackets duly painted, nuts, washers, cutting and making good the walls floors wherever required as per direction of Engineer-Incharge. |
| 68 | Providing & fixing white vitreous china flat back urinal with automatic flushing systems (Hindware 60021 / Kerovit model No. KS 510) comprising of all plumbing, electronic and electrical items. CP brass flush pipe with CP brass elbow, CP brass spreader, CP wall flange, infrared photo cells, eyes electrically operated solenoid valve, step down transformer / equipment and any other item required to provide satisfactory functioning including necessary wall cutting / chasing and making good, as required for urinal flushing complete as mentioned above as per direction of Engineer-Incharge. |
| 69 | P/F 8mm dia C.P/S.S Jet with flexible tuble up to 1 Mtr long with S.S Trangular plate to European type W.C of approved quality and make |
| 70 | P/F 600x450mm levelled edge mirror of superior glass of approved quality complete with 6mm thick hard board ground glass to wodden cleats withC.P brass screws and washers complete |
| 71 | P/F of 600 x120x5mm glass shelf with edges off. Supported on anodised angle frame with CP brass brackets and guard rail complete fixed with 40mm screws , rawl plugs etc |
| 72 | P/F of Toilet paper holder (CP) |
| 73 | Providing and fixing liquid PTMT soap container 109mm wide 125mm high and of approved quality weighing not less than 105 gms |
| 74 | Providing and fixing PTMT liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with brackets of the same materials with snap fittings of approved quality and colour, weighing not less than 105 gms. |
| 75 | P/F PTMT towel rail with brackets fixed to wooden cleats with CP brass with concealed fitting arrangement of approved qaulity (600mm long toatl length 645mm, 78mm wide and effective hight 8mm weghining not less than 190gms |
| 76 | Construction of brick masonary inspection chambers/manholes brick work 9\" thick in cement mortar 1 : 4 incld: earth work , preparing base , laying foundation concrete 1 : 4 : 8 mix, plaster 1 : 4 mix incld: finishing , laying cement conc: floring 1 : 2: 4 (1 Cement : 2 coaese sand : 4 grade stone) with finishing , making proper channels incld: RCC slab 1 :2: 4 withG.I manhole coverof approve make incld:all carraiges complete |
| 77 | Providing and fixing 2 HP C.O Motor incuding all fittings 2 No. ball valve , non return valve vertical /horizontal shelter base electric panel awitch board with DP MCB 20 Amph |
| 78 | Providing and fixing of Gesers incld: all necessary fitings complete job 50 litre as approved by EIC |
| 79 | Providing and fixing stainless steel A ISI 304 (18\"\"X36\"\"X8\"\"(with drain board )kitchen sink as per IS 13983 with C.I. brackets and stainless steel plug 40mm including painting of fittings and brackets, cutting and making good the walls wherever required. Kitchen sink with drain board 510 x 1040mm bowl depth 225mm (Dry Canteen/Kitchen). |
| 80 | Providing and fixing, testing and commissioning of C.P brass Sink mixer with regular swinging spout (wall mounted model) with connecting legs and wall flanges complete as required and making good as per direction of Engineer-in-charge Cat No. QQT 7309, KB2011024). |
| 81 | Providing and fixing heavy class SS grating plane floor trap and setting in floor with cement mortar to matach the floor finish as per direction of Engineer-in-charge (size 100mm dia) ISI marked. |
| 82 | Earth work in excavation by mechanical means (hydraulic excavator) in trenches for foundations, drains, pipes, cables etc. (not exceeding 1.5 m in width) and for shafts, wells, cesspits and the like not exceeding 10 sqm on plan, including dressing of sides and ramming of bottoms lift upto 1.5 m, including getting out excavated earth and disposal of surplus excavated earth as directed, within a lead of 50 metres:All kinds of Soils |
| 83 | Providing,Laying, spreading and compacting stone aggregate of specified sizes in uniform thickness, hand picking, rolling watering and compactingIncluding all carriages and lifts upto the site of work complete job |
| 84 | Providing and laying in position specified grade of cement concrete excluding the cost of centering and , shuttering , All work up to plinth level 1:4:8 (1cement: 4 coarse sand : 8 graded stone aggregate |
| 85 | Providing,Laying, spreading and compacting RBM/stone aggregate of specified sizes in uniform thickness, Ramming/compacting watering and Including all carriages and lifts upto the site of work complete job |
| 86 | Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-incharge. Note: - Cement in this item is @ 330 kg/ cum. Excess or less cement used as per design mix is content considered payable or recoverable separately.All works upto plinth level |
| 87 | Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-incharge. Note: - Cement in this item is @ 330 kg/ cum. Excess or less cement used as per design mix is content considered payable or recoverable separately.All works above plinth level upto floor V level |
| 88 | Centering and shuttering including strutting, propping etc. and removal of form work for: foundations |
| 89 | Walls (any thickness) including attached pilasters, buttresses, plinth and string courses etc |
| 90 | Lintel, beams, plinth beams, girders, bressumers and cantilevers. |
| 91 | Columns, pillars, piers, abutments, posts and struts |
| 92 | Stairs (excluding landings) except spiral staircases. |
| 93 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete Thermo-Mechanically Treated bars of grade Fe-500D or more |
| 94 | Septic Tank |
| 95 | Earth work in excavation by mechanical means (hydraulic excavator) in trenches for foundations, drains, pipes, cables etc. (not exceeding 1.5 m in width) and for shafts, wells, cesspits and the like not exceeding 10 sqm on plan, including dressing of sides and ramming of bottoms lift upto 1.5 m, including getting out excavated earth and disposal of surplus excavated earth as directed, within a lead of 50 metres:All kinds of Soils |
| 96 | Providing and laying stone Soling including Carriage upto the site of work |
| 97 | Providing and laying in position specified grade of cement concrete excluding the cost of centering and , shuttering , All work up to plinth level 1:4:8 (1cement: 4 coarse sand : 8 graded stone aggregate |
| 98 | Providing and laying in position specified grade of reinforced cement concrete including curing but excluding the cost of centering, shuttering, finishing and reinforcement. All works upto plinth level 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size) |
| 99 | Centering and shuttering including strutting, propping etc. and removal of form work for foundations |
| 100 | Walls (any thickness) including attached pilasters, buttresses, plinth and string courses etc |
| 101 | Suspended floors, roofs, landings, balconies and access platforms |
| 102 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level:Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 103 | Provision for supply and laying of manhole cover heavy duty 3\"x3\" Upvc |
| 104 | Soakage Pit |
| 105 | Earth work in excavation by mechanical means (hydraulic excavator) in trenches for foundations, drains, pipes, cables etc. (not exceeding 1.5 m in width) and for shafts, wells, cesspits and the like not exceeding 10 sqm on plan, including dressing of sides and ramming of bottoms lift upto 1.5 m, including getting out excavated earth and disposal of surplus excavated earth as directed, within a lead of 50 metres:All kinds of Soils |
| 106 | Dry random rubble masonry with hard stone in foundation and plinth: with Bond stone |
| 107 | Providing and laying in position specified grade of reinforced cement concrete including curing but excluding the cost of centering, shuttering, finishing and reinforcement. All works upto plinth level 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size) |
| 108 | Centering and shuttering including strutting, propping etc. and removal of form work for Suspended floors, roofs, landings, balconies and access platforms |
| 109 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level:Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 110 | Provision for supply and laying of manhole cover heavy duty 3\"x3\" |
| 111 | Electric part |
| 112 | Wiring for lighting points/fan points/ exhaust fan points/call bell points with 1.5 sq mm FRLS PVC insulated flexible stranded copper conductor wires in recessed or surface medium class PVC conduit, with 240V 6A modular switch , modular plate, suitable GI box/ PVC modular box and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable, etc. as required. (Havells/ Polycab/ Anchor/ Finolex/KEI/RR or equivalent make ) excl. cost of conduit. |
| 113 | Wiring for light/power plug points (15/16A heating/AC points) with 2x4 sq mm FRLS PVC insulated flexible stranded copper conductor wires in recessed or surface medium class PVC conduit along with 1x4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing, etc. as required. (Maximum two points shall be connected on one circuit).(Havells/ Polycab/ Anchor/ Finolex/KEI/RR or equivalent ) excl. cost of conduit |
| 114 | Supplying and fixing of suitable size GI box / PVC modular box with modular plate and modular cover in front on surface or in recess, including providing and fixing of 6 pin 15/16 A modular socket outlet and 15/16A modular switch, connections, etc. as required. (Havells/ SSK/ Anchor/ ABB/Schneider or equivalent) |
| 115 | Supplying and fixing of suitable size GI box / PVC modular box with modular plate and modular cover in front on surface or in recess, including providing and fixing of 2 no. 3 pin 5/6 A modular socket outlet and 2 no. 5/6A modular switch, connections, etc. as required. (Havells/ SSK/ Anchor/ ABB/Schneider or eq.) |
| 116 | Point wiring for 5A -10A socket out lets (computer points) with 2x2.5 sq mm (P+N)FRLS PVC insulated 660/1100volt grade flexible stranded copper conductor wires in recessed or surface conduiting system and earthing the point with 1 x 2.5 sq. mm single core copper wire (loop earthing),(Maximum two points shall be connected on one circuit).(Havells/ Polycab/ Anchor/ Finolex/KEI/RR or equivalent) excl. cost of conduit |
| 117 | Supply, installation, testing and commissioning of (2feet x2feet)36 Watt LED recessed/mounted (square) Down lighters having aluminum body, minimum 100lm/w, average life 50000 hours, Operating temperature -10`C to +45`C. The job includes replacement warranty of fixture if damaged/ burnt out what so ever reason for a period of two years reckoned from the date of successful commissioning/ handing over of site to the intending department. (Havells/ Philips/ Crompton/ Jaguar/Wipro). (commercial series) |
| 118 | Supply, installation, testing and commissioning of 12 Watt LED recessed/ mounted (round or square) Down lighters having aluminum body, minimum 100lm/w, average life 50000 hours, LM79 & LM80 test report should be from Govt. Approved NABL lab / Govt. Of India , Operating temperature -10`C to +45`C. The job includes replacement warranty of fixture if damaged/ burnt out what so ever reason for a period of two years reckoned from the date of successful commissioning/ handing over of site to the intending department. (Havells/ Philips/ Crompton/ Jaguar/Wipro). Commercial series. |
| 119 | Supply, installation, testing and commissioning of 6 Watt LED recessed/ mounted (round or square) Down lighters having aluminum body, minimum 100lm/w, average life 50000 hours, LM79 & LM80 test report should be from Govt. Approved NABL lab / Govt. Of India , Operating temperature -10`C to +45`C. The job includes replacement warranty of fixture if damaged/ burnt out what so ever reason for a period of two years reckoned from the date of successful commissioning/ handing over of site to the intending department. (Havells/ Philips/ Crompton/ Jaguar/Wipro). Commercial series. |
| 120 | Supply, installation, testing and commissioning of 100Watt LED Flood lighting luminaries having aluminum body, minimum 100 lm/w, the luminary housing should be aluminum and the luminary optics shall have a high efficiency with transmittance, average life 50000 hours, Operating temperature -10`C to +45`C. The job includes replacement warranty of fixture if damaged/ burnt out what so ever reason for a period of two years reckoned from the date of successful commissioning/ handing over of site to the intending department. |
| 121 | Supply, installation, testing and commissioning of 400mm sweep wall fans, incl. making of necessary connections. (Havells/ Philips/ Crompton/ Anchor). |
| 122 | Supply, installation, testing and commissioning of 200-250 mm sweep shutter type exhaust fans, incl. cost of ceiling rose and making of space in walls/ windows as per site and necessary connections. (Havells/ Philips/ Crompton/ Anchor). |
| 123 | Supply, installation, testing and commissioning of 1 star 1200 mm sweep ceiling fans of Havells / Crompton Greaves/Bajaj/ Anchor (Sample to be got approved), incl. cost of extension of GI rod (if required) and making of necessary connections. |
| 124 | Supply and fixing of two module stepped electronic fan regulator on the existing modular plate switch box, incl. connections but excluding modular plate etc. as reqd. |
| 125 | Supply and fixing of modular blanking plates on modular switch plates, excluding cost of switch plates. |
| 126 | Wiring for sub mains along with earth wire in FRLS PVC insulated 660/1100volt grade flexible stranded copper conductor wires in recessed or surface conduiting system, excluding cost of conduits(Havells/ Polycab/ Finolex/ Anchor/KEI/RR). |
| 127 | 2 x 2.5 sq.mm + 1x 2.5 sq. mm Lighting Circuits |
| 128 | 2 x 4 sq.mm + 1x 4 sq. mm Lighting sub main |
| 129 | 2 x 6.0 sq.mm + 1 x 6 sq. mm Lighting sub main |
| 130 | 4 x 16 sq.mm + 2 x 6 sq. mm Heating sub main |
| 131 | Supply and fixing of 25 mm dia./25 mm wide medium class PVC conduit along with accessories, including cutting the wall and making good the same as required. |
| 132 | Supply and fixing of 6 way (4+18) , Double door surface/ recess mounting , Horizontal type, 240/415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs, excluding cost of MCBs and Incomer. (Havells/Legrand/SSK) |
| 133 | Supply and fixing of 16 way , Double door surface/ recess mounting , Horizontal type, 240 V, SP&N MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs, excluding cost of MCBs and Incomer. (Havells/Legrand/SSK) |
| 134 | Supply, installation, testing and commissioning of 5-32A single pole rating 240/415V, 10 KA MCB suitable for inductive load in the MCB distribution board complete with necessary connections. (Havells/ Legrand/ L&T/ABB/ Schneider). |
| 135 | Supply, installation, testing and commissioning of 32/40A DP rating 240/415V, 10 KA MCB suitable for inductive load in the MCB distribution board complete with necessary connections. (Havells/ Legrand/ L&T/ABB/ Schneider). |
| 136 | Supply, installation, testing and commissioning of 63A DP rating 240/415V, 10 KA MCB suitable for inductive load in the MCB distribution board complete with necessary connections. (Havells/ Legrand/ L&T/ABB/ Schneider). |
| 137 | Supply, installation, testing and commissioning of 63A TPN MCB rating 240/415V, 10 KA MCB suitable for inductive load in the MCB distribution board complete with necessary connections. (Havells/ Legrand/ L&T/ABB/ Schneider). |
| 138 | SITC of wall/free standing floor mounted dust and vermin proof compartmentalized cubical panel for electrical Works, made out of CRCA sheet. Other parameters required as per point(a) Thickness of sheet shall not be less than 1.6 mm up to 600 mm length/width of any compartment and be of 2.0 mm above 600 mm. Load bearing structure shall be of 2.0 mm thick sheet supported by base M.S. channel if required. Side walls and cable alley compartment shaving bolted type doors with/without detachable extension type structure(b) Panel shall be duly treated for derusting in 7 tank process with de phosphating and with powder coating of minimum 70microns on both side of panel in desired shade The panel having PU/Neoprene rubber gasket of not less than 3mm thickness, required hardware, separate detachable gland plate M.S. base channel (min 75mm), hinged door with locking arrangement for equipment/switchgearc) Interconnection between bus bar and switch gears/cable shall be rigidly supported and made out by flexible copper wires (upto 125 amp) and by solid bus bar (> 125).(d) Only outer area on all sides shall be measured & panel to be fabricated only from CPRI approved fabricator, CPRI Test certificates to be submitted) All as per pre approved by Engineer in charge. |
| 139 | Providing and fixing following rating and breaking capacity and pole MCCB with thermo magnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. (Thermal Magnetic type, Adjustable type) |
| 140 | Normal Incoming |
| 141 | 250 Amp, 36 KA, FP MCCB |
| 142 | Aluminum Bus Bar 500 Amp set of 4 strips |
| 143 | ON Load Change Over Switch FP 160 amp. (Front operated) |
| 144 | Aluminum Bus Bar 300 Amp set of 4 strips |
| 145 | Digital Metering devices, comprising of Voltmeter, Ammeter, Selector Switch, Indicating Lamp, etc. |
| 146 | Outgoing |
| 147 | 100 Amp, TPN MCB 10KA |
| 148 | 63 Amp, 10 KA, DP MCB |
| 149 | Space for 16 way MCBs |
| 150 | Supply, laying, connecting and commissioning of 150 sq. mm 3.5 core PVC insulated and PVC sheathed /XLPE power cable of 1.1 KV grade Aluminum LT cable , incl. cost of required al. thimbles duly crimped.( Over head/under ground). |
| 151 | Providing of chemical earthing as per IS standards by way of digging 8 feet pit then embedding 2.5 mtr. Long GI earthing electrode, 60 mm dia. Connecting the plate with main control board by 10 SWG Copper wire with 1/2” dia. Full thread brass nut/bolts and washers, refilling the pit with chemical compound. |
| 152 | Supplying and fixing of modular 6A socket out let/ indicators on existing modular plate and switch box, incl. connections, etc. as required. (Havells/Anchor/Gold medal/Legrand/SSK)i.3 pin 5/6A socket. |
| 153 | ii. indicator. |
| 154 | Supplying and fixing following size of perforated painted with powder coating M S cable trays with perforation not more than17.5% in convenient sections, joined with connectors, suspended from the ceiling with M S suspenders including bolts and nuts, painting suspenders etc. as required. i. 200mm x 50mm x 1.6mm |
| 155 | Supply and installation of 32A modular/ industrial plug/socket with 32A DP MCB for ACs |
| 156 | Supplying and laying of DWC HDPE (Double Wall Corrugated High Density Polyethylene) pipe, 200 mm dia.(OD – 200 mm & ID – 175 mm) ISI marked along with all accessories like sockets, bends, couplers, etc. with fitting and cutting, jointing, etc. (under ground), including excavation and refilling the trench after laying the pipes. (complete job) |
| 157 | Supply, installation , testing and commissioning of 3 star rating 1.5 Ton Inverter type split Air Conditioners suitable for operation on AC supply single phase 50Hz 230V with hermetically sealed inverter compressor with air cooled condenser latest R410A/ R-32 refrigerant fan motor, start and run capacitors, relay and over load protector internal unit with one indoor and one outdoor unit. The indoor unit fitted on wall by employing suitable clamps and the outdoor unit will be placed on angle iron stand fitted with nut/bolts outside the room to avoid noise, including standard length of suitable size copper tubing covered with nitrilic foam, topping up with refrigerant for additional length of piping if required, PVC flexible drain pipe, suitable capacity 3 core sheathed/ PVC insulated copper cable and a battery operated wireless remote unit. The job includes repairs to walls wherever the same are cut and the AMC of AC for a period of one and a half year from date of successful commissioning. (Daikin/ Blue Star/ LG). |
| 158 | Supply, installation , testing and commissioning of relay type voltage stabilizer suitable for 1.5 Ton AC operating from input voltage 90- 260Volt thereby producing output voltage of 230volts +_ 3%. (4 KVA) |
| 159 | Providing / laying of shock proof rubber mat of 2mtr x1 mtr and 12 mm thick in size. |
| 160 | Supply, installation , testing and commissioning of 20 KVA, 3-Phase, 415V,LT, Unbalanced AVR of Essentials, KE, ALBA, Chinar, Cosco make, operating from input voltage of L-L=155-460V & L-N=90- 265V, thereby producing the output voltage of 415V +_2% Phase to Phase and 230V +_2% Phase to Neutral. The AVR should have inbuilt Over voltage protection, Under voltage protection & Over loading with TDR. The stabilizer shall be servo controlled automatic, ONAN cooled and provided with first filling of fresh filtered transformer oil having required di-electric strength. The stabilizer shall be capable of smooth operation up to 10% un-balanced in the load currents complete with servo bye pass system consisting of 100A four pole manual type change over switch. The job also includes all applicable taxes, carriages, loading and unloading. |
| 161 | Supply and erection of Mild Steel Swaged Tubular Pole confirming to IS: 2713-1980 ( Part I-II) with base plate. The pole shall be made from steel tube and pipe (IS : 1141, Fe 410)including excavation of the pit and filling up the same with cement concrete of M15 Grade (1:2:4 mix) from base plate to 50 cm above ground level, earthing terminal, cable entry with 32mm dia B- class GI cable sleeves. The pole shall be painted with 2 coats of red oxide primer and 2 coats of enamel paint of silver. The job also includes the cost of form work and carriage of all required materials. (9 mtr. 410 SP-28) |
| 162 | Providing and fixing of detachable type round or square bracket (suitable for 6 lights) of 40 mm dia. GI pipe as per requirement. |
| 163 | Supply, laying, connecting and commissioning of 16 sq. mm 2 core PVC insulated and PVC sheathed /XLPE power cable of 1.1 KV grade Aluminum LT cable , incl. cost of required al. thimbles duly crimped. |
| 164 | Providing & Fixing of IKO8 IP-66 protected high power LED flood light system with single piece Pressure die cast aluminum housing, toughened glass diffuser with suitable lenses on LED to achieve various beam angles, of high power LED of 3 to 5 watt each. Integrated potted driver as a unique BIS R number having more than 85 % and in compliance to BIS certified and Trade mark certificate. The System level Luminary efficacy >=1 wt.LED driver Input Voltage AC 120 to 270 V AC with High voltage Cutoff V AC and up to resetting Safety Power Factor >0.95, THD(I) <10%, driver current) <=750mA. driver should be Phase to phase protection of 440 V for 4 Hrs. Electrical Connector, Surge Protection Min >24KV internal and 10KV external but inside driver compartment, System life of 50000 Burning hours with 70% of Initial Lumens maintained, CRI>70 and CCT 5700k$355K. Manufactures Word Mark/Name Engraved/Embossing/Screen printing on die cast housing to allow traceability/ authenticity. Fixture shall be IS 10322 Complianced.OEM Must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79/LM80) Certificate/ report with liable warranty of product/accessories from.OEM shall be submitted. (150Watt ) |
| 165 | Supplying and drawing FRLS PVC insulated copper conductor single core cable through pole up to light. A. 2 x 2.5 sq. mm (P + N) |
| 166 | B. 1 x 2.5 sq. mm (Loop/ Common earth) |
| 167 | Providing and fixing/ laying of earthing station by way of placing GI electrode rod in a pit connected through GI strip. (complete job) |
| 168 | Providing and fixing of sheet steel enclosure box ( suitable size for housing of voltage stabilizer , 40/63A DP MCB 01 no, 5-32A SP MCBs 3 nos. and a suitable connector) with knock out for cable entry / out including fixing with nut bolt fastener etc required complete in all respects to be fixed on the pole at a height of at least 8 feet from ground level. Please Enable Macros to View BoQ information |