| 1 | Demolition of cement concrete in ground floor and paving n.exc 15 cm thick (below or above ground level complete . |
| 2 | Demolition of brick or stone masonary built in cement mortar complete |
| 3 | Taking down cement plastering on stone wall/brick wall etc including racking out of joints hacking for key scrubbing down with water etc |
| 4 | M&L brick work with sub-class \"B\" bricks, straight or curved on plan exceeding 6 M mean radius built in CM 1:6. |
| 5 | M&LCement concrete type D 2, 1:4:8 (using 40 mm gradedstone aggregate) in sub base of flooring, hard standing,Manhole, drain etc. |
| 6 | M&L 75mm thick PCC 1:3:6 type C2 (using 40mm graded stone aggr) as in plinth protection/path finishing the surface even and smooth without using extra cement complete all as spd and directed. Note : Plinth protection shall be laid in (1:20) slope. The concrete shall be laid at a stretch not exceeding 3metre in length. Joint gap between adjoining slab, at corners and at junctions ofwalls shallnot exceed 10mm in width and shall be sealed with mastic filling i.e. one part of bitumen 85/ 25 grade mixed with 3 part of sand. Top surface of concrete shall be finished even and smooth without using extra cement. Joints shall be provided at not more than 3 metre interval at corner and as junction of walls. |
| 7 | M&L machine pressed precast coloured concrete coloured interlocking paver blocksany shape and size confirming of IS 15658: 2006 of 60mm thick, M-35 laid and jointed with grey cement and pigment. |
| 8 | M & L for 25mm thick Sand filling under floors or in foundations including watering and consolidation |
| 9 | M & L for Plain Cement Concrete Type B1 1:2:4 (using 20 mm gradedstone aggregate) cast in situ inkerbs or mud stops, rounded or chamfered on edges of paving blocks as directed including use and waste of form work. |
| 10 | M&L 15mm thick rendering on wall in CM 1:4 onbrick/concrete surfaceand finishing the surface even and smooth with out using extra cement. |
| 11 | M&L 15mm thick rendering on wall in CM 1:6 onbrick/concrete surfaceand finishing the surface even and smooth with out using extra cement. |
| 12 | M&L Machine cut kota stone slab flooring 20-25mm thick over 20mm thick cement screed bed in CM 1:6 laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing upto mirror finished complete. |
| 13 | M&L Machine cut kota stone slab flooring 20-25mm thick as in skiritng, riser of steps etc laid over 10mm thick cement plaster in CM 1:4 laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing upto mirror finished complete. |
| 14 | Taking down chowkats or frames with shutters (without taking of shutter from the frame)of any description alongwith fittings n.exc 1.5 sqm each |
| 15 | Taking down chowkats or frames with shutters (with out taking of shutter from the frame) of any description alongwith fittings exc 1.5 sqm n.exc 4 sqm each |
| 16 | S&F pressed steeldoor framewith one or more rebate including necessary fixing lugs, hinges, lock stricking plate of size 105 x60mm |
| 17 | M&L for PCC Type B0-1:2:4 using 12.5mm graded aggregate as in filling of pressed steel frame, hold fasts and similars articles |
| 18 | Cutting holes in brick walls incement mortar for inserting holdfasts and making good dismantled portion in cement mortar 1:3 or cement concrete 1:2:4 Type B-1 as required built in cement motar in brick wall depth of embedded portion of holdfast exc half brick but n exc one brick |
| 19 | S&F2nd class hardwood 35mm thick Plain, framed, panelled shutters (any number of panels), with panels of timber flat on both sides (feather edged), or of veneered particle board medium density, wood particle board with commercial face veneers: supplied and fitted to chowkats. |
| 20 | Steel window/ventilator 1.25 mm thick Box typeERW hollow P section of size 60mm x 25 mm single rebated comprises skelton shutter ERW Sec 50 MM x 20 mm and 1 mm thick and two openable leaf consisting two Nos sash bar of T-section 20 mm x 3mm complete welded to frame with one vertical mullion of ERW box type T section of size 60mm x 25 mm and 1.25 mm thick including cuttings holes and making good dismantled portion in PCC (1:2:4) type B-1, including shop coat primer and following fittings welded to shutters:-i) Hold fasts 150 mm long,12mm x 3mm made to shape-04 No’s, (ii) Handle of Z sec 20mm x 25mm , 100mm long per leaf-1 No’s(iii) MS tower bolt 150 mm long per leaf -2 No’s(iv) Z sec 20mm x 25 mm , 100 mm long stopper per leaf -1 No(v) Cleat 55 mm long of hollow square 15mm x 20mm x 63 mm welded to hinges per leaf -01 No (vi) MS pintal hinges of size 75mm x 12 mm per leaf-02 Nos (vii)Fabrication and fixing arrangement complete |
| 21 | All as per description of item No 20.00 above but glazed shutter. |
| 22 | S&F framed work such as grills & gates, gratings with ends of bars shouldered on forged in spickes, framed guard bars, barred iron doors, ladders, framed balusters, walk ways, rallings, framework of water tanks and similar work conforming to Fe-290 Gde-E-165 |
| 23 | S&F Galvanisedmild steel wire cloth, 0.56mm nominal dia of wire and avg erage with aperature 1.18 mm fixed with tinned tacks, or galvanised wire staples. |
| 24 | S&F 3mm thick sheet glass ordinary quality and glazing with oil putty in square n.exc 0.50 sqm in each pane complete all as specified. |
| 25 | S&F Butt hinges, medium weight cold rolled 100 mm size ISI marked. |
| 26 | S&F aluminium anodised barrel tower bolts of extruded section 150mm long all as specified/ |
| 27 | S&F Extruded aluminium alloy handles fabricated type anodised 150mm size |
| 28 | S&F aluminium alloy anodised sliding door bolts 250 mm long with hasp, staple (bolt type)and fixing clips of sheet cast or extruded section and fixing bolts and sliding bolts of extruded sections as specified. |
| 29 | Dismantling asbestos cement (corrugated or semicorrugated sheets in roof coverings. |
| 30 | M & L for pre galvalume aluminium zinc coating GI based corrugated steel sheet 0.50 mm thick of any colour having tensile strength of 550Mpa as in roof covering/cladding to wll fixed with self tapping screws as specified. |
| 31 | M&L Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws asspecified |
| 32 | Cutting chases, pinning in. making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills,sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring,etc., and making good, cutting not exc 10 cm girth in brick wall. |
| 33 | M & LProviding cement concrete 1:2:4 type B-1 using 20mm graded aggregate) in roof kerbs or mud stops, rounded or chamfered on edges. |
| 34 | Dismantling of mild steel work of any description not other wise provided for |
| 35 | S &F Roof trusses (framed), trussedpurlins, crane gantries, rails andfastenings and heavy bracket framing (Beam, tee, angle, channelor flat sections) includingdistance pieces, cleats etc.Fe 410 -W(Gde-E- 250) quality-A. |
| 36 | Dismantling boarding of any description fixed in any posn with nails. |
| 37 | S & F for4 mm thick of size 600x600mmHSPC (high pressure Steam Cured) pre-primetered self embossed, textured designer boardE-Board Classic to be fixed GI powder coated grid/section size 600mmx600mm with main runner 38x24x0.9mm thick ,cross tee 28.6x24x0.9 mm and wall angle 19x19xo.9 mmduly suspended with 6mm dia GI bar hangers 1200mm centre to centre both ways fixed with steel dash fasteners or from purlin from the roof with alignment clip including providing provisions for light fixtures of any size complete all as specified and as directed by the Engr-in-Charge. |
| 38 | M & L for applying two coat of synthetic enamelled paintover one coat of red oxide primer including preparation of new steel surfaces of any description not otherwise described over 10 CM girth or width all as directed by the Engr in charge. |
| 39 | M & L for applying two coat of synthetic enamelled paint over one coat of pink primer including preparation of new wood surfaces of any description not otherwise described over 10 CM girth or width all as directed by the Engr in charge. |
| 40 | Material and labour for preparation of new plastered surfaces on walls and applying two coats of oil distemper over one coat of chalk whitening complete all as specified. |
| 41 | Material and labour for preparation of new plastered surfaces on walls and applying two coats of cement base paintover one coat of cement primer complete all as specified. |
| 42 | Taking down carefully aluminium / copper point wiring (light / fan / socket or power) complete including fitting such as switches, ceiling roses, socket, light fittings, regulators etc complete and making good disturbed surfaces of walls, floors |
| 43 | Taking down main switch / DB as directed by Engineer-In-Charge. |
| 44 | Taking down unserviceable submain/ cable of any size as directed by Engineer-In-Charge. |
| 45 | M & L for concealed point wiring complete with 2.5 sqmm single core multistranded copper conductor FRLS, PVC insulated and unsheathed cable 650 /1100 volts grade drawn through & including PVC conduit, medium grade with accessories like bends, tees, junction boxes etc fix on wall or ceiling surfaces all as specified including 2.5 sqmm , FRLS type , copper multistrandedcable as earth wire including switch/sockets and regulator and including cover plate white colour all as specified and directed for: |
| 46 | Supply and fixing piano/flush type switch 1 way 16A, |
| 47 | Supply and fixing piano /flush socket 1 way 16 amp |
| 48 | M & L for concealed point wiring complete with 1.5 sqmm single core multistranded copper conductor FRLS, PVC insulated and unsheathed cable 650 /1100 volts grade drawn through & including PVC conduit ,medium grade with accessories like bends, tees, junction boxes etc fix on wall or ceiling surfaces all as specified including 1.5 sqmm , FRLS type , copper multistrandedcable as earth wire includingswitch/sockets and regulator and including cover plate white colour all as specified and directed for:One light /fan/cell bell point controlled by one one way switch as directed engineer-in-charge |
| 49 | One 3 pin piano /flushsocket outlet, 5Amps, independent with other switch |
| 50 | One 3 pin piano/flushsocket outlet 5 amps on same board with other switches. |
| 51 | Supply and fixing piano/flush type switch 1 way 6A, |
| 52 | Supply and fixing piano/flush type socket 1 way 6 amp |
| 53 | Supply and fixing SHEET METAL ENCLOSURESFOR DB\"SSPN WHEN MCBs TO BE USED 8 way double door |
| 54 | S&F MCB SPN40 to 63 Ampsrating 240 volts ,10KA\"c\" curve miniature circuit breaker (MCB) of following poles and current carrying capacity in the MCB DB complete with connection testing and commisioning |
| 55 | M & L for sub main wiring with TWOcore PVC insulated and unsheathed cable 6 sqmm with multi stranded copper conductor , FRLS type cable drawn throughand including PVC concealed conduit of suitable size complete with all accessories alongwith provn of 2 run of 6 sqmm PVC insulated and unsheathed ,multi stranded copper conductor , FRLS type cable as earth wire. (2 runs of cable and one run of conduit shall be measured as one length) |
| 56 | M & L ceiling rose surface bakelite 65 x 50 mm three terminals complete all as specified. |
| 57 | Earthing complete with galvanised steel earth plate electrode 60cm×60cm.× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less\"than 1.5 metres below normal ground level, connected to galvanised earth lead wire 4.0mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 connected to earthing test point all as specified or indicated including testing on completion |
| 58 | Supply and fixing M & L Lamp holder, PVC/Polycarbonate type with back plate suitable for batten fittings |
| 59 | S&F LED tube light fitting 20W (Double side) including LED lamp 20W with 2100 lumen output with internal surge protection device of 4KV with voltage band of 140-280V CRI-6500K (White light) fixtures box type and connecting electrically to ceiling rose using PVC insulated and overall sheathed flexible copper conductor of size 0.50mm 3 core complete all as specified and directed. |
| 60 | Supply and fixing recess /ceiling mounting LED light 1x36 watt cool white light of 6500k complete all as specified and directed . |
| 61 | Supply and fixing S/F MCB SP 6-32 Amps 240 volts |
| 62 | Supply and fixing PVC insulated, amoured cable, heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 10 sq. mm 2 core |