| 1 | Dismanling wrought iron or mild steel work of any description not otherwise provided for, complete all as specified and directed. |
| 2 | Dismantling plain or corrugated steel sheeting any gauge, thickness, including Naintal or similar pattern roof coverings complete all as specified and directed |
| 3 | S & F steel work in Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc confirming to I.S.1161- 1979 Fe 410-W (GdeE- 250) complete all as specified and as directed by Engineer-In-charge |
| 4 | S&F Pre-painting galvatume aluminum zinc coating GI based corrugatedsteel sheet 0.50 mm thick of an colour having tensile strenght of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified complete all as specified and directed |
| 5 | S&F Pre-painting galvatume aluminum zinc coating GI based plain steel sheet 0.50 mm thick of an colour having tensile strenght of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified complete all as specified and directed |
| 6 | M & L for preparation of new steel surface any description not otherwise described and exc 10cm width or girth applying two coats of synthetic enamel paint over a coat of red oxide all as specified and directed. |
| 7 | Dismantling of wall and ceiling boards (fibre, pulp, insulation, etc) or insulation boards/slabs/blankets, any thickness inclduding cover fillets. |
| 8 | Dismantling timber scantlings 40 sq.cm and over in section, in any positions as in framed work. |
| 9 | -Ditto- all as per item 8above but in fillets, rails, posts, rafters, purlins, etc under 40 sq.cm in section. |
| 10 | M & L for second class hardwood clean sawnscantlings as in timber framed and fixed complete all as specified and directed. |
| 11 | Ditto all as per item above but except timber |
| 12 | M & L for second class hardwood plain fillets, square, rectangular or triangular in section, clean sawn, secured with nails or brads of sectional area exc 3 & n.exc 6 sq.cm complete all as specified and directed. |
| 13 | M & L for second class hardwood plain fillets, square, rectangular or triangular in section, clean sawn, secured with nails or brads of sectional area exc 13 & n.exc 25 sq.cm complete all as specified and directed. |
| 14 | M & L for 6mm thick (No of ply 5) plywood, grade BWR, type BB, fixed with nails to timber frame work as in ceiling complete all as specified and directed. |
| 15 | M & L for 18/19mm thick Particle board one side, medium density flat pressed, single layer type or three layer type with BWR type adhesive, fixed with screw to timber frame work as in ceiling complete all as specified and directed. |
| 16 | M & L for 12mm thick Particle board both side, medium density flat pressed, single layer type or three layer type with BWR type adhesive, fixed with screw to timber frame work as in ceiling complete all as specified and directed. |
| 17 | M & L for preparation of new wooden surface any description not otherwise described and exc 10cm width or girth applying two coats of synthetic enamel paint over a coat of pink primer all as specified and directed. |
| 18 | Taking down chowkats or frames not exc 1.5 sq.m each but with shutters (without taking off shutters from the frames). |
| 19 | Taking down chowkats or frames exc 1.5 sq.m but n.exc 4 sq.m each but with shutters (without taking off shutters from the frames). |
| 20 | S & F second class hardwood plain, solid, straight chowkats and frames,wrought, framed rebated on the solid, rounded or chamfered, put together with glue pinned at joints. |
| 21 | S & F 35 mm thick factory made second class hard wood, kiln seasoned and chemically pressure treated plain framed, panelled shutter (any number of panel) with lock rail and panel of 9 mm BWP Commercial ply or 12 mm veneered particle board with commercial face veneers on both faces or 10 mm bison panel.complete all as specified and directed. |
| 22 | S & F (factory Made)2nd class hard wood35 mm thick glazed and skelton shutters open rebated and prepared to receive gauge.(Without sash bars) edges of framing plain chamfered or rounded fittedwith cut and mitred beads for securing glass etc sizes of members of shutters as specified in SSR Part-I section 8 clause 8.20 (a) supplied and fitted to chowkatscompleteall as specified. |
| 23 | S & F of 30 mm thick (Batten thickness) 2nd class hardwoodglazed and skeleton shutters, open rebated and prepared to receive glass, gauze etc. divided into squares, with plain, chamfered or rounded, mitered and rebated sash bars, edges of framing plain, chamfered or rounded, fitted with cut and mitered beads for securing glass etc. and size of the members of shutter is as specified in clause No. 8.24 (a) of MES schedule part – I (Specifications - 2009) complete all as specified and directed. |
| 24 | S & F clamps, hold fast,hook washer & similar small articles conforming to Fe-290 Gde-E-165. |
| 25 | M & L for providing cement concrete type C1 1:3:6 using 20mm graded stone aggregate as in hold fast blocks. |
| 26 | S & F 125mm butt hinges, medium weight, cold rolled mild steel and fixed. |
| 27 | -Ditto- all as per itemabove but 75mm long. |
| 28 | S & F 300mm length aluminium alloy, anodised, sliding door bolt hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy and fixed. |
| 29 | S & F 150mm Aluminium handles, cast type, anodised |
| 30 | S & F 125mm Aluminium handles, cast type, anodised |
| 31 | S & F 150mm aluminium, anodised, barrel tower bolts of extruded section and fixed. |
| 32 | S & F 125mm aluminium, anodised, barrel tower bolts of extruded section and fixed. |
| 33 | S & F in repair hydraulically regulated door closer, (die cast) body designation No 3, universal type suitable for door shutters of 851 to 1000mm in width and weight b/w 61 to 80kg complete. |
| 34 | S & F mild steel 300mm ordinary rat tail rod pattern springs, including roller and roller plate complete. |
| 35 | M & L sheet glass, 4mm thick ordinary quality and glazing with oil putty or beadings in square not exc 0.5 sqm in each pane. |
| 36 | S&F Galvanised mild steel wire cloth, 0.56mm nominal dia of wire and average width of aperture 1.18mm and fixed with tinned tacks, or galvanised wire staples all as specified and directed. |
| 37 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises. |
| 38 | Demolition of cement concrete (unreinforced) in ground floors and pavings n exc 15 cm thickness (below or above ground level) all as specified and directed. |
| 39 | M &L 75mm thick cement concrete type C2 1:3:6 using 40mm graded stone aggregate finishing surface even and smooth wuthout using extra cement a in plinth protection all as specified and directed. |
| 40 | M &L 75mm thick cement concrete type D2 1:4:8 in sub base floor complete all as specified and directed. |
| 41 | M &L chequered cement concrete tile 20cm x 20cm x 25mm thick, set, jointed and pointed in neat cement slurry over 20mm thick scrred bed in cement mortar 1 :4as in floors with grey cement and pigment complete all as specified and directed. |
| 42 | M & L for vitrifiedceramic tiles light shade 10mm thick but not exceeding 0.36 sqm, in floors etc, set and jointed in neat cement slurry and pointed in white or coloured cement to matchover 15mm thick screed bed in cement mortar 1:6 etc set and jointed in neat cement slurry and pointed in coloured cement to match the surface of tile completed all as specified and directed by E-in-Charge. |
| 43 | M & L for vitrifiedceramic tiles light shade 10mm thick but not exceeding 0.36 sqm, in dado/ skirting in verticle surfaces etc floors etc, set and jointed in neat cement slurry and pointed in white or coloured cement to matchover 10mm thick screed bed in cement mortar 1:4 etc set and jointed in neat cement slurry and pointed in coloured cement to match the surface of tile completed all as specified and directed by E-in-Charge. |
| 44 | M & L for non skid ceramic tiles 7 to 8 mm thick (square/rectangular) area of each tile exceding 0.11 sqm but not exceeding 0.18 sqm, in floors etc, set and jointed in neat cement slurry and pointed in white or coloured cement to matchover 15mm thick screed bed in cement mortar 1:4 complete all as specified and directed. |
| 45 | M & L for joint free glazed ceramic coloured tiles in vertical surface 350mm x 250mm x 7mm / 450mm x 350mm x 7mm thick set and jointed in neat cement slurry and pointed in white or coloured cement to matchover 10mm thick screed bed in cement mortar 1:4 complete all as specified and directed. |
| 46 | Demolition of brick work or stone / boulder massonary, build in cement mortar incl all quoins , pillers etc. |
| 47 | M & L for Precast cement concrete block massonary 1:3:6 type C1 with solid block exc 10 cm in width and setting in cement mortar 1:6 complete all as specified and directed by E-in Charge. |
| 48 | Taking down cement or cement lime plaster, any description on brick or stone walls, etc including racking out joints, hacking for key, scrubbing down with water etc. |
| 49 | M & L for rendering 15mm thick on fair faces of brick or concrete surfaces in cement plaster 1:6 and finished even and smooth (without using extra cement). |
| 50 | M & L for rendering 15mm thick on fair faces of brick or concrete surfaces in cement plaster 1:4and finished even and smooth (without using extra cement). |
| 51 | M & L complete removal of existing treatment and applying 3mm thick Birla wall care putty and applying two coats of distemper oil emulsion over a coat of primer on wall complete all as specified and directed. |
| 52 | M & L for preparation of new plastered surface or previously untreated walls surfaces and applying two coats of cement base paint over coat of primer on wall complete all as specified and directed. |
| 53 | Taking up or down 15mm bore steel water tubing & connections, incl cleaning for existing or offrening credit as per sch of credit all as directed. |
| 54 | S&Fin repair bib taps 15mm diafancy type chromium plated, screwed down, screwed for iron pipe or for brass ferrule and fixed. complete all as specified and directed by Engr In Charge. |
| 55 | S&Fin repair 15mm dia stop valve chromium plated, fancy type screwed down, high pressure with crutch or butterfly handle screwed both end for iron pipe complete all as specified and directed by Engr In Charge. |
| 56 | S&Fin repair PVC connections 45cm long and 15mm diachromium plated brass nuts and PVC washers on both ends, complete all as specified and directed by Engr In Charge. |
| 57 | S&Fin repairVitreous China Urinal flat back size 465x355x265mm white with grating and union for discharge pipe incl fixing plug , bedding, urinal against wall in CM 1:2 securing urinal to plug pointing around back in cement fixing autmetic flushing cisternwith bracket flush pipe grating and union for discharge pipe etc complete all as specified and directed by Engr In Charge. |
| 58 | S & F in repairs for Wash Hand basins, Vitreous China, white, flat back, size 550x440mm, including cutting for and pinning in ends of brackets or erecting stand, angle bracket (but exclusive of fixing of supply, waste pipe, taps) complete all as specified and directed. |
| 59 | S&Fin repairs PVC Valveless, syphonic action type, flushing cistern of 10ltr capacity, high or low level, white with inlet, ball valve, float and and handle incl brackets, and connections to flush pipes of polythelene of low or high density or PVC 32mm dia for low level cistern complete all as specified and directed by Engr-in-charge. |
| 60 | S&Fin repair Vitreous China wash down water closet pan ( pedestal pattern), white (excluding fixing bolts, flushing cistern and flush pipe) incl Plastic water closet seat, black, closed patern with flat bottom and cover and mild steel chromium plated or alumined hinging device vitrious Chaina pedestal pattern WC incl PVC seat cover and flush pipe etc complete all as specified and directed by engr-in-charge. |
| 61 | S&F in repair 600mm x 450mm bevelled edge mirror of selected quality glass , mounted on 6mm thick AC building board or commerical plywood and fixed to wodden plugs with chromium plated brass screws and cupwashersetc complete all as specified and directed by engr-in-charge. |
| 62 | S&F in repair Soap dish, any type, fixed to plug with chromium plated brass screws embedded in the wall all as specified and directed by Engr-in-charge. |
| 63 | S&F in repair 20mm dia brass chromium plated tubular towel rail, D type, 60cm long b/w flanged and directed by Engr-in-charge. |
| 64 | S&F cast iron floor trap 75mm out let dia with grating including jointing to waste pipefixed in cement concrete type B-1 (1:2:4).. |
| 65 | S&F in Sheet glass shelf assembly consisting of 5.5mm thicksheet glass shelf 12cm wide with chromium plated bracket guards and railing 60cm longcomplete all as specified and directed by Engr In Charge. |
| 66 | S&F in repair , brass chromium plated , toilet paper holder fixed with chromium plated brass screw, completed all as specified and directed by Engr-in-Charge. |
| 67 | S&F 15mm bore galvanised steel tubes, \"medium grade\" with all fitting and fixed complete to walls and ceiling or laid in floors completed all as specified and directed by E-in-Charge |
| 68 | Supply & fixing in repair 15mm pillar tapsfancy type cast copper alloy, with capstan heads, chromium plated, screwed down , high pressure, with or without lettered \"Hot\" or Cold\" with long screwed shanks and fly nuts, screwed for iron pipe and fixed. Bore of pipe in 15mm complete all as specified and directed by Engr In Charge.. |
| 69 | S&F in repair 32mm dia PVC waste pipe for WHB complete all as specified. |
| 70 | S&F in repair Health faucet (ABS Body) mild steel CP 15mm dia pipe with 1.25m long flexible tube and ABS wall hook incl fixed in position complete all as specified. |
| 71 | S&F in repair C.P grating 100mm square/round with or without hole complete all as specified. |
| 72 | S&F in 20 mm dia ,Al alloy curtain rails with brackets fixed in repair. |
| 73 | Excavation in trenches, not exceeding 1.5 meter wide and not exceeding 1.5 meter in depth for foundation etc or for shafts, wells, cesspits, manholes, pier holes etc not exceeding 10 Sqm area on plan and not exceeding 1.5 meter in depth and getting out in soft/disintegrated soil. |
| 74 | M & Lfor PCC(1:4:8) type D-2 using40mm graded stone aggregate in foundation/filling and mass concrete. |
| 75 | M&L for 40 mm thick Damp proof course to horizontal or vertical surfaces including necessary form work in cement concrete 1:2:4 type B-0 (Using 12.5 mm graded stone aggregate) |
| 76 | M & L for Reinforced Cement Concrete (nominal mix) type B1 1:2:4 (using 20 mm graded aggregate) in foundations including Plinth beam, base for column, rafts, footings and mass concrete complete all as specified and directed. |
| 77 | M&L for RCC (nominal mix) type B1 1:2:4 (using 20 mm graded aggregate), as in Columns, pillars, piers, posts and struts &similar RCC works all as specified and directed. |
| 78 | M & L for Reinforced Cement Concrete (nominal mix)type B1 1:2:4 (using 20 mm graded aggregate) in Beams, cantilevers, lintels over 1.5 M span complete all as specifed and directed |
| 79 | M & L for Reinforced Cement Concrete (nominal mix)type B1 1:2:4 (using 20 mm graded aggregate) in Chajjas and the likecomplete all as specified and directed |
| 80 | M & Lfor 10mm dia and over TMT bars cut to length bentto shape as required including binding withmild steel annelid wire not less than 0.90mm dia all as specified. |
| 81 | M & Lfor 5mm dia and over up to 10 mm dia TMT bars cut to length bentto shape as required including binding withmild steel annelid wire not less than 0.90mm dia all as specified. |
| 82 | Use & waste formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, plinth beams and similar works for rough finished surface complete all as directed. |
| 83 | Use & waste form work to sides of pillars, posts and columns for rough finished surface of concrete complete all as directed. |
| 84 | Use & waste Form work to sides and soffits of floor or roof beams, lintiles cantilever etc for rough finished surface complete all as directed. |
| 85 | Use & waste Form work to edge of concrete , flats, treads, breaks in floors, window cills etc for rough finished surface exc 5 cm but n. exc 10 cm widecomplete all as directed. |
| 86 | M&L for rendering 5 mm thick on concrete surfaces of wall / vertical surfaces in cement mortar 1:3, and finish the surface even and smooth without using extra cementall as specified and as directed by Engineer-In-Charge. |
| 87 | S&F pressed steel frames 125x60mm for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc., complete, as specified. |
| 88 | M&L Plain Cement Concrete1:3:6 type C1 filling of pressed steel frame and hold fast block etc. |
| 89 | Supply & fixing steel windows/ventilator with side hung shutters including projection type hinges with steel handle, tower bolt and steel peg stay, complete with glazing bars dovetailed or welded all as specified. |
| 90 | S & F Rolled Mild Steel sections confirming to Fe 410-W (Gde-E-250) quality A as in main and cross beams, hip and jack rafters; purlins where connected to common rafters fixed with angle cleats or other connecting plates |
| 91 | S&Fplates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachmentincluding welding etc all as spfd and directed by EIC.Fe-410-W(gde-E-250) quality B. |
| 92 | S&F Anodised aluminium snap grid framed work for false ceiling and incl hangers 6mm dia G.I (upto 1200mm long) adjusting level fixed to roof slabs/purlin/rafter with the help of cleats made out of G.I flat 40x3mm size 60mm long and expansion holdfastener 12.5mm dia 40mm long complete. |
| 93 | M&L for false ceiling with gypsum board, perforated type, ,factory madematt finish surface/pre painted surface,600 x 600 mm in size and 12 to 15 mm thick on exisitingaluminium snap grids 605 X 605 mm as in ceiling. |
| 94 | S&F in repair19 mm dia curtain rods fancy type, mild steel chromium plated with fixing brackets, stops, rollers all as specified and as directed by Engr-in-charge. |
| 95 | S&F floordoor stopper 140 mm of aluminium alloy body and tongue anodised with hard drawn steel springcomplete all as directed by Engineer-in-charge. |
| 96 | Supply& fixing MS barrel tower bolt of 100mm long stove enamelled black with bright bolt complete all as specified and directed by Engr-in-charge. |
| 97 | Supply & fixing 300 mm longmild steel sliding door bolts plate type stove enamelled black with bright bolt not less than 12mm dia with and including a minimum of 6 bolts and nuts four on bolts plate and two on couple plate and fixed complete all as specified and directed by Engr-in-charge. |
| 98 | Supply& fixing MS pressed handle oval type stove enamelled black of 125mm long fixed with screw to shutter complete all as specified and directed by Engr-in-charge. |
| 99 | S&F plain sheet glass of 3 mm thick in Squares not exceeding 0.50 Sqm in each pane with oil putty and clips complete all as directed by Engineer-in-Charge. |
| 100 | Preparing New plastered surfaces and applying two coats of distemper oil emulsion includingpreparatory to distempering on surfaces of walls. |
| 101 | Preparing new plastered surfaces and applying Two coats of cement base paint on surfaces of walls over one coat of white wash. |
| 102 | M & L for rendering 10 mm thick on fair faces of brick or concrete surfaces in cement plaster 1:6 and finished even and smooth (without using extra cement). |
| 103 | Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc all as specified and directed by Engr-in-Charge |
| 104 | Taking down unserviceable submain wiring and service cablealongwith batten /PVC conduits etc. and making good disturbed surfaces of walls/floors and match the existing surface all as directed at site. |
| 105 | Taking down unserviceable main switches, DBs with MCB SP/Isolators by unscrewing form board complete all as specified and directed by Engineer-in-Charge |
| 106 | Matrial & Labourfor point wiring using approved colour coding as per IS with using approved coper coding as per IS 1.5 Sqmm multistranded , 1100 volt grade copper conductor FRLS cable of PVC insulated and unsheathed type alongwith 1.5 Sqmm PVC insulatedstranded copper conductor cable for continuous earthing in & incl PVC casing & caping with accessories having ISI mark fixed on wall surfaces / ceilingincluding provision PCV Box on top for fixing switches sockets etc. all as specified for one light point / fan / Bell point controlled by one switch complete all as specified and directed by Engineer-in-Charge. |
| 107 | All as per Srl item No 106 here-in-before but controlled with one 3 pin socket outlet 5 Amp onthe same board with other switches with cables 1.5 Sqmm complete all as per specified and directed by Engineer-in-Charge. |
| 108 | All as per Srl item No 106 here-in-before but controlled with one 3 pin socket outlet 5 Amp on theindependent board withcable 1.5sqmm including provision of 1.5 sqmm single core multistanded PCV insulated copper conductor as earth conducting conductor complete all as per specified and directed by Engineer-in-Charge. |
| 109 | All as per Srl item No 106 here-in-before but controlled with one 3 pin socket outlet 15 Amp, independent board withcable 2.5sqmm including provision of 2.5 sqmm single core multistanded PCV insulated copper conductor as earth conducting conductor complete all as per specified and directed by Engineer-in-Charge. |
| 110 | Point wiring complete with 1.5 sqmm single core PVC insulated with 1.5 sqmm single core PVC insulated FRLS cable 1100 volts grade with multi standed copper conductor drawn through and including non metallic rigid PVC conduit with all conduit accessories (concealed)/ Casing and caping and including provision of 1.5 sqmm PVC insulated copper cable FRLS as earth continuity conductor, fabricated steel terminal box made out of 1.6 mm thick MS sheet concealed in walls with 3 mm thick bakelite sheet ISI marked top cover with brass screws and cup washers for housing the switches, socket outlets, fan regulators etc forOne light /Exhaust Fan point controlled by one switch, all as specified and as directed. |
| 111 | All as per Srl no 110 here-in-before but call bell/buzzer other switches controlled by one push buttom with cable 1.5 sqmm compelete all as per specfied and directed by Eng-In -Charge. |
| 112 | All as per Srl item No 110 here-in-before but controlled with one 3 pin socket outlet 5 Amp on same board with other switches with cables 1.5 Sqmm complete all as per specified and directed by Engineer-in-Charge. |
| 113 | All as per Srl item No 110 here-in-before but controlled with one 3 pin socket outlet 5 Amp onthe independent board with other switches with cables 1.5 Sqmm complete all as per specified and directed by Engineer-in-Charge. |
| 114 | All as per Srl item No 110 here-in-before but controlled with one 3 pin socket outlet 15 Amp, independent board withcable 2.5 sqmm including provision of 1.5 sqmm single core multistanded PCV insulated copper conductor as earth conducting conductor complete all as per specified and directed by Engineer-in-Charge. |
| 115 | Supply and fixing ofswitch piano type 5 Amp, 230 Volt, flush button single pole one way complete all as specified and directed by Engineer -in-Charge, |
| 116 | Supply and fixing of socket outlet 3 pin 5 Amp 2-in-one230 Volt flush typecomplete all as specified and directed by Engineer -in-Charge. |
| 117 | Supply and fixing ofswitch piano type 15 Amp, 230 Volt, flush button single pole one way complete all as specified and directed by Engineer -in-Charge, |
| 118 | Supply and fixing ofSocket outlet 2 in 1, 3 pin, 5 and 15amp flush type single pole one way complete all as specified and directed by Engineer -in-Charge, |
| 119 | Supply and fixModular switch 1 way 6A, 1 module type, 230 volts, ISI marked complete. |
| 120 | Supply and fixSocket, 6A - 2/3 pin combined 2 module, multipurpose flush type, ISI markedcomplete all as specified and as directed. |
| 121 | Supply and fixSocket 6A/16A - 2/3 pin combined 2 module, multipurpose flush type, ISI markedcomplete all as specified and as directed. |
| 122 | Supply and fixModular switch 1 way 16A, 1 module, multipurpose flush type, ISI markedcomplete all as specified and as directed. |
| 123 | Supply and fix MODULAR WHITE COVER PLATE WITH FRAMEWhite cover plate with frame, 3 module ISI markedcomplete all as specified and as directed. |
| 124 | Supply and fix MODULAR WHITE COVER PLATE WITH FRAMEWhite cover plate with frame, 4 module ISI markedcomplete all as specified and as directed. |
| 125 | Supply and fix MODULAR WHITE COVER PLATE WITH FRAMEWhite cover plate with frame, 6 module ISI markedcomplete all as specified and as directed. |
| 126 | Supply and fix MODULAR METAL FLUSH BOXMetal flush box 3 moduleISI markedcomplete all as specified and as directed. |
| 127 | Supply and fix MODULAR METAL FLUSH BOXMetal flush box 4 moduleISI markedcomplete all as specified and as directed. |
| 128 | Supply and fix MODULAR METAL FLUSH BOXMetal flush box 6 moduleISI markedcomplete all as specified and as directed. |
| 129 | M&L Ceiling rose, 3 terminal with ISI markall as specified and directed by Engr-In-Charge. |
| 130 | Material and labour forlamp holder, PVC/ Polycarbonate type with back plate suitable for batten fittings. Make : Anchor/leader/havells |
| 131 | Supply and fix LED Batten 10W (warm light) 2 ft (Approx) length ultra slim square profile with extruded polycabonate, enviromenental friendly, energy efficient , connected with 23/.0076 twin core PVC flexible cable complete all as specified and directed.Make- Havells / Philips / Crompton |
| 132 | Supply and fix in replacement LED Batten 20W , 4 ft (Approx) length ultra slim square profile with extruded polycabonate, enviromenental friendly, energy efficient , connected with 23/.0076 twin core PVC flexible cable complete all as specified and directed.Make- Havells / Philips / Crompton |
| 133 | Supply and fixing9 watts LED lamp (warm) all as specified and directed by Engr-in-Charge. Make: Havells |
| 134 | Supply and fixing9 watts LED backup lamp of 4 hours backup, with auto switch on mechanism in case of power failure, works as regular 9w lamp in normal mode and a 4w lamp in backup mode all as specified and directed by Engg-in-Charge. Make: Havells |
| 135 | Supply & Fixing bulk head light with 10 W LED Lamp complete. Make Bajaj Cat No BIBWP 10W LED or equivalent of Wipro and CG/Philips |
| 136 | Supply & Fixing 2X2 Recessed mounted LED 36 WSQUARE Slim compact ,aluminuim die cast edge lit pannel,Recess mountedSquare fixture with opal diffuser and separater eletronic driver LED 6500 K 15 Watt with best in class design for long lasting performance connected withcopper conductor cable of suitable size. Make Havells/Bajaj/Crompton. |
| 137 | Supply and fixing ofsheet metal enclosure double door for DBs single pole and neutral for 04 way 240 volt complete all as specified and directed by Engineer-in-Charge |
| 138 | Supply and fixing ofsheet metal enclosure double door for DBs single pole and neutral for 08 way 240 volt complete all as specified and directed by Engineer-in-Charge |
| 139 | Supply and fixing ofsheet metal enclosure double door for DBs single pole and neutral for 12 way 240 volt complete all as specified and directed by Engineer-in-Charge |
| 140 | Supply and fixing amp rating 240V, 10KA \"B\" curve miniature circuit breaker (MCB) of following poles and current carrying capacity in the MCB DB complete with connection testing and commissioning. (i) SP 5 to 32 Amp |
| 141 | Supply and fixing amp rating 240V, 10KA \"B\" curve miniature circuit breaker (MCB) of following poles and current carrying capacity in the MCB DB complete with connection testing and commissioning. (ii) SPN63 AMP |
| 142 | Supplying and fixing 1100 volts grade heavy duty cable PVC insulated 10 sqmm two core aluminium solid conductor , served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including 4mm suspension wire, one twin core cable flat or circular |
| 143 | S&Fexhaust Fan made of sturdy Engineering plastic complete with louvers shutter, voltage 230V,50 Hz, RPM 1200, Copper winding of sweep 250 mm complete all as per specified and directed by Engineer-in-Charge. |
| 144 | Supplying and fixing 1100 volts grade heavy duty cable PVC insulated 16 sqmm two core aluminium solid conductor , served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including 4mm suspension wire, one twin core cable flat or circular |
| 145 | M&L for earthing complete with galvanised steel earth plate electrode 600x600x6mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below the ground level with top edge of the plate not less than 1.5 mtr below the normal ground level connected to the galvanised earth wire 4 mm dia by means of bolts, nuts hook nuts and washers of galvanization of steel all as shown in electrical plate no 3connected to earthing testing pointall as specified or indicated including testing on completions. |
| 146 | Taking down and Refixing sheet metal Encloser Double Door for DBs single pole and Neutral for 8 way 240 volt complete all as Specfied and Directed by Eng-in-charge. |
| 147 | Taking down and Refixing 240 volts 10 KA B\" curve miniature circuit Breaker (MCB) of single pole and current Carrying capacity 6 to 32 Amp in the MCB DB Compelete with connection testing and commissioning. |
| 148 | Taking down and Refixing of Miniature Circuit Breaker (MCB) SPN 40 Amp rating 240 volts,10KA \"C\" curve in the MCB DB complete with connection testing and commissioning. |
| 149 | Supply and fixing bell push flush type Switch piano type 5 amp,230 volts flush botton Single pole one way Complete all as specfied and directed by Eng-in-charge. |
| 150 | Schedule of Credit |