| 1 | SUB-ABSTRACT OF COST- A ( Civil Works ) Earth work in excavation of foundations of bridgesculverts, buildings including handling of material with a combined lead of 15 metres dressing of bed and sides stacking the excavated soil from the edge of excavation and subsequent filling around :-(b) For semi-conglomerate soil of the nature of pick jumper work.[As per CSR itme No. 6.7 (b)] |
| 2 | Cement concrete 1:6:12 With stone aggregate 40mm gaugemixing by mechanical means using concrete mixer volumetric type. [As per CSR itme No. 10.8 (b) (ii)] |
| 3 | First class brunt brick work laid in cement sand mortar 1:6 in foundation and plinth. [As per CSR itme No. 11.3 (i)] |
| 4 | Reinforced cement concrete M-20 mechanically batch mixed using batch type concrete mixer as per IS:1791 and vibrated by needle vibrator but excluding steel reinforcement centring and shuttering in foundation and plinth.(As per CSR Item no. 10.15) |
| 5 | Shuttering for faces ofconcrete foundations andfoundationbeam and plinthbeam( verticalorbettering)[As per CSR Item No. 9.1] |
| 6 | First class brunt brick work laid in cement sand mortar 1:6 in first storey up to 4.00 m above plinth level. [As per CSR item No. 11.4 (i)] |
| 7 | 115 mm thick brick wall laid in cement sand mortar 1:4 without reinforcement in superstructure.[As per CSR item No. 11.36] |
| 8 | Reinforced cement concrete M-20 mechanically batch mixed using batch type concrete mixer as per IS:1791 and vibrated by needle vibrator but excluding steel reinforcement centring and shuttering in superstructure.[As per CSR item no. 10.20] |
| 9 | Centering and shuttering for sides and soffits of beam, beams, launching girders, bressumers, lintels.[As per CSR Item no. 9.6] |
| 10 | Centring and shuttring for flat surfaces such as suspended floors , roofs , landings , chajjas , shelves \"etc.[As per CSR item no. 9.8] |
| 11 | Cold twisted detormed (Ribbed/ Tor steel) Bars (Fe 500 grade as per IS 1786-2008) , for R.C.C works, where not including in the complete rate of RCC including bending and binding placing in position complete.[As per CSR item no. 18.18] (AOR) |
| 12 | Terracing consiting of tiles 22.86x11.43x3.83cm laid over 25 mm mud plaster 7.5 cm mud filling on another layer of 25mm mud plaster including two coats of bitumen laid hot at 1.65 Kg. /Sqm top of R.C.C. slab including grouting with cement sand mortar 1:4 and top surface to be left clean after wire brushin.[As per CSR item no. 13.13 (i)] |
| 13 | Cement concrete 1:2:4 gola 10cm x 10cm concave quadrant along junction of roofs with parapet wall finished smooth, where specially specified.[As per CSR item no. 13.55] |
| 14 | Top Khurra 0.6mx0.6m for rain water pipe in 25mm thick cement concrete 1:2:4 over 50.00 thick cement concrete 1:8:16.[As per CSR item no. 13.45] |
| 15 | Providing and fixing 110 mm dia . U.P.V.C Rain water pipe of 4 kgf./sqm as per IS:4985 including jointing during masonary complete as per specifications and to the entire satisfaction of Engineer-in- charge. [As per CSR item no. 13.74] |
| 16 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipe single socket (working pressure 4kg.cm2) confirming to IS 4985, including fixing MS Clamps.(i) U-PVC pipe (working pressue 4kgf/sqm) pipe 110 mm dia. [As per CSR Item no. 13.75(a)] |
| 17 | 20 mm thick cement plaster 1:5 in two coat work.[As per CSR Item no. 15.21] |
| 18 | 12.5 mm thick cement plaster 1:5 [As per CSR item no.15.10] |
| 19 | 10 mm thick cement plaster in 1:3 under side of ceiling.[As per CSR item no.15.37] |
| 20 | Base course of floor consisting of 100mm thick cement concrete 1:8:16 with stone aggregate 40 mm gauge with 100 mm fine sand using mechanical mixer for mixing of material. [As per CSR 14.3] |
| 21 | Providing and laying vitrified floor tiles of different sizes in light colour shades made using Double Charge technology (thickness to be specified by the manufacturer) with water absorption’s less than 0.08% and conforming to IS : 15622 of approved make in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement: 4 fine sand), complete. (a) Size 600x600 mm [As per CSR item no. 14.113 (a)] |
| 22 | Providing and laying Anti skid Ceramic floor tiles of size 300x300 mm x 10 mm thick of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on flooring skirting and dado in 12.5mm thick cement plaster 1:3 in base and jointed with @ 3.3 kg/sqm including pointing the joints with white cement and matching pigment etc., completewhite cement slurry in joints including corners angles and beading. [As per CSR Item no.14.72] |
| 23 | Providing and fixing 1st quality ceramic glazed wall tiles Matt/Semi Matt/Glosy/Highly Gloss finish/Highlighter/emboss conforming to IS : 15622 (thickness to be specified by the manufacture of approved make in all colours, shades except burgundy, bottle green, black of size 600 x 300 mm as approved by Engineer-inCharge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:4 (1 cement: 4 fine sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade complete.[As per CSR item no. 14.128] |
| 24 | Providing and fixing aluminum work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/appropriate z sections and other sections conforming to Is: 733 and IS : 1285 of Jindal, Hindalco, Mahavir or equivalent make approved by Engineer in Charge , fixed with rawl plugs and screwsor with fixing clips, or with expansion hold fasteners including necessary filling up of gaps at junctions, at top, bottom and sides with required PVC Plug/neoprene felt etc. aluminum sections shall be smooth, rust free, straight, mitered and jointed mechanically wherever required including cleat angle, aluminum snap beading for glazing/paneling, C.P.brass/stainless steel screws, all complete as per architectural drawings and the directions of Engineer-InCharge. (Glazing and paneling to be paid for separately) : (a) For fixed portion and chawkhats[As per CSR 17.45 (a)] |
| 25 | For shutters of doors, windows & ventilators including providing and fixing hinges/pivots and labour for fixing of fittings wherever required including the cost of PVC Plug / neoprene gasket required.[As per CSR Item no. 17.45 (b)] |
| 26 | Providing and fixing glazing in aluminum door, window, ventilator shutters and partitions etc. with PVC Plug/ neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminum snap beading shall be paid in basic item) (ii) Float glass panes of 4 mm thickness :-[As per CSR Item no. 17.47 (ii)] |
| 27 | Providing and fixing 12 mm thick prelaminated particle board flat pressed three layer or graded wood particle board conforming to IS: 12823 Grade l Type ll, in paneling fixed in aluminium doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of engineer-in-charge. Pre-laminated particle board with decorative lamination on both sides.[ As per CSR-2020item No. 17.46-ii ] |
| 28 | Providing and fixing Stainless steel jali on Windows and ventilators.(M.R) |
| 29 | Cost of aluminum fittings complete for doors, windows such as tower bolts, handles,Stoppers and screw etc. for these fittings (Excluding sliding bolt).[As per CSR Item no. 17.23 (i) & (ii)] For shutter area up to 0.50 sqm :- |
| 30 | For shutter area above 0.50 sqm :- |
| 31 | Preparation of plastered or concrete surface for painting (including sand papering the surface) using ready mixed cement based wallputty by applying two or more coats to get required finish.[As per CSR 16.65] |
| 32 | Distempering with Acrylic washable oil bound distemper (of approved manufacture) two or more coats over one priming coat to give an even shade. [As per CSR 16.10] |
| 33 | Finishing walls with cement based water soluble exterior paint such as snowcem, robbiacem etc. two or more coats to give an even shade. [As per CSR Item no. 16.13] |
| 34 | White washing ( Three coats )[As per CSR item no. 16.3] |
| 35 | Wrought iron & Mild steel ladders, framed grills, gratings etc. with ends of bars riveted or molded forged framed window guards, barred iron doors stair case iron railing etc. including cost of bolts and nuts, screws, welding rod complete fixing in position.[As per CSR Item no. 18.4] (AOR) |
| 36 | Providing and fixing M.S. angle iron 40x40x6mm chowkhat including iron hold fasts butt hinges fixed in position, finished with red lead non setting primer complete in all respect.[As per CSR 18.29 (a) & (b)] (AOR) Single rebate :- |
| 37 | For double rebate. |
| 38 | Providing and fixing helical door spring 150mm (superior quality) including necessary screws, complete (b) Iron Helical spring [ As per CSR-2020item No. 17.41 ( b ) ] |
| 39 | 30 mm thick Hollock wood cup board shutter with plywood panels or faced on both side fixed in position (excluding the cost of handles, bolts hasp with staple but including the labour for fixing them) (a) 30 mm thick [ As per CSR-2020item No. 17.12-ii (a) ] |
| 40 | Factory manufactured Solid flush door fixed in position iron hinges, etc (excluding the cost of any fittings other than specified above but including labour for fixing the same in position.(Code : IS 2202-1 (1999). (c) Decorative with teak facing on both sides edges lipped with teak with laminated core(iv) 35mm thick[As per CSR 17.27 (c) (iv)] |
| 41 | Wire gauge Hollock wood door shutter without springs housed in chowkhat.(A) 35 mm thick[As per CSR 17.11 (ii) (A)] |
| 42 | Providing and fixing aluminum sliding door bolts ISI marked anodized (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with nuts and screws etc. complete :[As per CSR 17.49 (a) & (b)] Size 300mm x 16 mm :- |
| 43 | Size 250mm x 16mm [As per CSR-2020item No. 17.49 b ] |
| 44 | Applying priming coat with metal primer on new steel or iron work including preparation of surface with special quality primer.( CSR item No. 16.20 ) |
| 45 | Applying pink primer or aluminum priming coat on wood work including preparation of surface knotting and stopping etc. [As per CSR item no.16.16] |
| 46 | Painting two or more coats excluding priming coat with synthetic enamel paint in all shades on wood work, metallic or plastered, concrete surface to give an even shade.[As per CSR 16.17] |
| 47 | SUB-ABSTRACT OF COST- B ((WATER SUPPLY AND SEWERAGE) Excavation in trenches with straight or open cutting in streets, lanes or in open areas for intramural sullage drains, intramural intercepting drains and outfall drains storm water channels and other work contingent or incident thereto, by mecanical means (JCB or Hydraulic excavator) including manually dressing of bed, trimming of sides and sides slopes to full dimensions and depth as shown on the drawings or as shall be required by Engineer-in-charge including dressing to correct sections and dimensions according to templates and levels, dewatering of rain water, diversion of traffic, providing and fixing and maintenance of caution boards, fencing, night signals, watching etc. subsequent refilling , watering and dressing upto ground level for lead upto 15 m and for all lifts including disposing surplus soils up to 15 metre complete in all respects.(A) Depth upto 2.00 m.(iii) For Semi Conglomerate soil having gravel bolder above 40% up to 50% [As per CSR Item no. 29.1 (B) (A) (ii)] |
| 48 | Providing and fixing in position H.C.I. soil waste vent or antisyphonage pipes to I.S.I. specification of E.D.C manufacture or of any other reputed firm including cutting, jointing, wastage, but excluding cost of lead jointing.[As per CSR item no. 30.74 (i) (b) & (c)] (c) 75mm i/d H.C.I. pipe lines laid complete:- |
| 49 | (b) 100 mm inner dia HCI pipe in Bath Room :- |
| 50 | Providing, lowering, cutting & jointing salt glazed stone ware pipes and specials ISI marked as per IS: 651-2007 class Sp-1 into trenches for all depths and laying out the same to correct alignment, gradients, levels etc., cutting of concrete beds and joints holes, supporting the pipes and specials, in correct position in a suitable rigid manner while the same are being jointed and until the surrounding benching, haunching and envelopes are completed including jointing of pipes and specials in trenches, using cement sand mortar 1:1 and best spun Jute yarn as per IS:1887, finishing and trowelling of each joint at an angle of 45 degree with the longitudinal axes of pipe, watering, keeping the joint covered and wetted till the same are cured, testing the sewerage line for leakage and making all leakages and defects good as laid in the contract specification, chipping and finishing the cut surface to uniform finish to the entire satisfaction of engineer-in-charge Including all cartage etc complete in all respects(a) 100mm i/d pipe.[As per CSR Item no. 29.41 (a)] |
| 51 | Providing and fixing in position C.I. gully trap cover weighing approximately 7.26 kg and frame for gully trap chamber clear opening size 300mm x 300mm and out side size 330mmx330mm including painting the exposed surface with 3 coats of black bitumastic superior paint of approved manufacture etc. [As per CSR item no. 30.75 (a) ] |
| 52 | Providing and fixing H.C.I. Floor traps conforming to I.S.I. Specification of reputed firm of the self cleaning design with S.S. grating with frame with or without vent arm andincluding cement concrete 1:2:4 under and around the floor trap where required upto floor level complete in all respects including cutting and making good the walls and floors,etc.(a)With 100mm x 75mm i/d Floor Trap (weighing 4.0 Kg)[As per CSR Item no. 30.79 (a) |
| 53 | Providing lead caulked joints to H.C.I. pipes and specials conforming to I.S.I. Specification of E.L.C. manufacture or any other reputed firm including cost of lead yarn,fuel and tools etc. [As per CSR item no. 30.77 (A) (b &(c) ](c) 75mm i/d (1.13 kg.) |
| 54 | (b) 100 mm internal dia ( 1.36 kg ) :- |
| 55 | Providing and fixing in position H.C.I special for soil waste vent or anti syphonage pipes to I.S.I specifications of E.L.C manufacture or any other reputed firm including cutting and wastage etc. cutting holes in walls roofs orfloors etc. and making good to its original condition but excluding cost of lead joining. (A) For 100mm i/d pipes[As per CSR item no. 30.81 (A) (i) & (vi)] (i) 100 mm internal dia for Heal Rest Bend |
| 56 | (vi) 100 mm internal dia Cowls |
| 57 | Providing and fixing in position SS Grating with frame of approved make (to the approval of engineer in charge) complete in all respects. [As per CSR item no. 30.80] |
| 58 | Providing and fixing in position Chinaware European type water closet P trap or S trap of approved make (to the approval of the Engineer-in-charge) consisting of 10 ltr. PVC flushing cistern ISI marked, PVC short bend 32 mm dia including cost of seat cover complete in all respect and to the entire satisfaction of Engineer-in-charge. [As per CSR item no. 30.4] |
| 59 | Providing and fixing in position vitreous chinaware white lavatory suites of approved make (to the approval of Engineer-in-charge) consisting of C.P. brass waste 32mm dia with one C.P. brass pillar tap including Rack Bolt Screw Pair 115mm long complete in all respect.Size 550 mm x 400 mm x 815 mm[As per CSR Item no. 30.37 (ii)] |
| 60 | Providing and fixing in position towel rails / ring of approved make (to the approval of Engineer-in-charge ) fixed in with rawl plugs embedded in walls with brass screws complete in all respect.(a) C.P. brass towel Rails size 15mm dia 610mm long [As per CSR Item no. 30.58] |
| 61 | Providing & Fixing in position 5mm thick bevelled edge mirror of superior glass (of approved make) complete with 4mm thick hard board backing fixed in with rawl plugs 50mm, C.P. brass screws and washers and S/S Studs on top complete in all respect (as required by the Engineer-in- Charge) (b) Size 550mmx400mm[As per CSR item no. 30.61 (b)] |
| 62 | Providing and fixing in position C.P. brass soap dish of approved make (to the approval of Engineer-in-charge ) fixed into wall with rawl plugs and C.P brass screws complete in all respect.[As per CSR Item no. 30.60] |
| 63 | Providing & Fixing in postion 15 mm i/d bib cock of approved make (to the approval of Engineer-in-charge) complete in all respect.(iv) Brass Bib cock/Stop cock 15mm x 400gm [As per CSR item no. 30.65 (A) (iv)] |
| 64 | Providing & Fixing in postion stop cock / Angle valve of approved make (to the approval of Engineer-in-charge ) complete in all respect. [As per CSR item no. 30.66 (a), (b) & (c)]C.P.brass 15mm stop cock Male and female end |
| 65 | C.P.brass 15mm Concealed stop cock with flange :- |
| 66 | C.P.brass 15mm Angle valve without flange :- |
| 67 | Providing and fixing jet spray with 2\"-6\" long PVC pipe.(a) With C.P. Brass nut [As per CSR item no. 30.8 (a)] |
| 68 | Providing and fixing P.V.C Waste Pipe Collapsiable 32mm complete in all respect. [As per CSR item no. 30.20] |
| 69 | Providing ISI Marked G.M ferrule as per IS:2692, drilling and tapping cast iron pipe lines of all diametres and screwing in Ferrule and connections complete in all respect[As per CSR item no. 28.34 (e) &(b) ]20mm i/d Ferrule heavy duty |
| 70 | 15 mm i/d Ferrule medium duty |
| 71 | Providing and laying, jointing, fixing, testing ISI Marked G.I. Pipe (as per IS 1239) BClass, including cost of Specials such as tees, bends, sockets elbow etc., cutting, threading and testing in trenches in the ground complete. (b) 20mm i/d [As per CSR item no. 28.36 (b)] |
| 72 | Providing and laying, jointing, fixing, testing ISI Marked G.I. Pipe (as per IS 1239) BClass, including cost of Specials such astees, bends, sockets elbow etc., cutting, threading and testing in trenches in the ground complete.(b) 15m i/d [As per CSR item no. 28.36 (a)] |
| 73 | Providing, fixing and jointing G.I Union Couplings(of approved make with the approval EIC) as per IS 1879 in G.I. Pipe lines complete in all respect. (a) 15mm i/d G.I. Union[As per CSR item no. 28.40 (a)] |
| 74 | Construction of brick masonry inspection chambers size as given below upto 0.60 metre average depth in 1:5 cement sand mortar, C.C.1:4:8 ( 150mm thick) in foundation, cement concrete 1:2:4 benching 12.50mm thick cement plaster 1:2 with a floating coat of 1mm thick of neat cement, R.C.C. 1:2:4 slabs 100mm thick cement concrete topping 50mm thick with 455mm x 455mm, 455mm x 610mm inside R.C.C. inspection chamber cover and frame (Weight as per I.S.I specifications) painted with 3 coats of black bitumastic paint conforming to I.S.I complete as per standard design. 600mm x 900mm inside with 455mm x 455mm cover and frame light duty double seal. [As per CSR item no. 29.60 (c)] |
| 75 | Providing & placing in position on terrace (at all floor levels) HDPE water storage tanks of approved make (to the approval of Engineer - in-charge) with cover with suitable locking arrangement and making necessary holes for inlet, outlet and over flo pipes but without fittings and base support for tank. (a) Triple Layer Tanks [As per CSR item no. 30.97 (a)] |
| 76 | Cutting holes upto 23cm square through B.B. in cement walls or stone masonary wall in cement for pipes, and making good the same & finishing according to existing finish where required.Through wall 22.86 cm thick. [As per CSR item no. 28.56 (b) ] |
| 77 | Providing and fixing in position G.I. Tank Nipple of approved make (to the approval of Engineer-in-charge) in PVC Water storage tanks complete in all respect. (b) G.I. tank nipple 20mm i/d [As per CSR 30.98] |
| 78 | Providing and fixing in position automatic brass Ball Cock in tanks. Brass Ball Cock with rod andPlastic BallBrass Ball Cock with rod andPlastic Ball (ii) 20mm i/d (As per CSR Item no. 30.96 (B) (ii)] |
| 79 | SUB-ABSTRACT OF COST- C (SEPTIC TANK) Earth work in excavation for storage and sedimentation tanks, high level tanks, filter beds, clear water reservoirs, pump houses, sumps, screening chambers and other similar works having straight or open cuttings in foundations trenches etc. with 3D Excavator/ JCB including manually dressing of bed, trimming of sides and side slopes to full dimension and depth as shown on the drawings or as shall be required by Engineerin-charge, including dressing of bottom and sides of trenches, stacking the excavated soil clear from the excavation and subsequent filling around plinth/structures including watering dressing and disposal of surplus soils as directed upto 15 metre complete in all respects. (A) Depth upto 1.5 m B.G.(ii) For Ordinary gravel soil having gravel upto 40%[As per CSR item no. 29.2 (A) (ii)] |
| 80 | (B) Where depths of excavation exceeds 2.0 metre below ground levels or total quantity of excavation is more than 100 cum[As per CSR item no. 29.2 (B)] |
| 81 | Cement concrete 1:5:10 With stone aggregate 40mm gaugemixing by mechanical means using concrete mixer volumetric type. [As per CSR item no.10.9 (b) (ii)] |
| 82 | First class burnt brick work laid in cement sand mortar 1:5 in foundation and plinth. [As per CSR item no.11.5] |
| 83 | Reinforced cement concrete M-20 mechanically batch mixed using batch type concrete mixer as per IS:1791 and vibrated by needle vibrator but excluding steel reinforcement centring and shuttering in foundation and plinth. [As per CSR item no. 10.15] |
| 84 | Centering and shuttering for flat surfaces such as suspended floors, roofs, landings, chajjas, shelves etc.[As per CSR Item no. 9.8] |
| 85 | Cold twisted detormed (Ribbed/ Tor steel) Bars (Fe 500 grade as per IS 1786-2008) , for R.C.C works, where not including in the complete rate of RCC including bending and binding placing in position complete. [As per CSR item no. 18.18] |
| 86 | Conglomerate floor 40mm thick cement concrete topping 1:2:4 using mechanical mixer for mixing of material.[As per CSR Item no. 14.6] |
| 87 | Floating coat of 1:5mm thick neat cement laid in one operation to the topping. [As per CSR Item no. 14.4] |
| 88 | 12.5 mm thick cement plaster 1:4.[As per CSR Item no. 15.9] |
| 89 | Providing & fixing 560 mm, 500 mm and 450 mm internal diametre circular or 450 mm x 600 mm clear inside opening rectangular RCC manhole cover and frame ISI marked as per IS:12592-2002 including carriage from the stores of the Engineer-in-charge to site of work, loading, unloading including stacking and setting the same to correct lines over manholes including cement concrete copping (M:20) around the frame etc. Dia of steel for lifting hook is 16mm. (for EHD and HD).(A) RCC Man hole cover with Frame.(a) 560mm i/d RCC man hole cover with frame as per ISI.(ii) Heavy duty.[As per CSR item no. 29.34 (A) (a) (ii)] |
| 90 | Providing orange colour safety footrest of minimum 6mm thick plastic encapsulated as per IS:10910 on 12mm dia steel bar confirming to IS: 1786 having minimun cross section as 23mm x 25mm and over all minimum length 263mm and width as 165mm with minimum 112mm space between rotruted legs having 2mm tread on top surface by ribbing or chequering besidesn necessary and adequate anchoring projections on tail length on 138 mm as per standard drawing and suitable to with stand the bend test and chemical resistance test as per specification and having manufacturer\"s permanent identification mark to be visible even after fixing, including fixing in manholes with 230x150x75cm cement concrete block 1:2:4 (1 cement: 2 sand: 4 stone aggragate) complete as per design.[As per CSR Item no. 29.35] |
| 91 | Supply of stone / brick aggregate |
| 92 | Filling stone or spall:(a) on Level [As per CSR Item no. 23.44 (a)] / labour rate |
| 93 | Providing and fixing 100 mm dia PVC Tee |
| 94 | Providing & fixing P.V.C. Bend 110 mm dia for soakage pit |
| 95 | Providing & fixing P.V.C. cowl |
| 96 | SUB-ABSTRACT OF COST-D (ELECTRICAL WORKS) RECESSED PVC CONDUIT PIPE WIRING SYSTEM WITH MODULAR SWITCHES:Wiring in PVC insulated copper conductor single core FR cable (ISI marked) overall 1.5sq. mm, 1100volts grade to be laid in heavy gauge PVC conduit pipe 20mm/ 25mm dia. (ISI Marked) recessed in wall etc., complete with powder coated/anodized concealed metal boxes (1.6mm thick with Brass lugs) required for suitable number of modules (Modular accessories) for having Step type electronic fan regulators (two module) 100watts, bell push, 6Amp. 2/3 universal socket (shuttered), 16/20Amp. combined/ universal Socket (shuttered), 6/10Amp. Switches, 16/20Amp. switches with indicator etc. and covered with Frame Plate etc., PVC connector (For Fan Box and Call Bell), Steel Hooks, Sheet metal fan box (1.6mm thick shape hexagonal), Circula junction Boxes (Four way PVC 1½\" deep for walls and CI 3\" deep for ceiling), bonding to earth with PVC insulated copper conductor single core FR cable (ISI marked) 1sq. mm, 1100volts grade (For 6Amp. wall socket & plug control point) and other petty material etc., including the cost of above material, cutting and filling up of chases (with finishing the surface):-[As per CSR Item no. 34.2 (i) (b), (iii), (v) & (vi)(i) (b) Wiring fan point (With fan box) |
| 97 | (iii) Wiring light point |
| 98 | (v)Wiring 6Amp. Plug control comprising wall socket point |
| 99 | (vi)Wiring 16/20Amp. power plug control point |
| 100 | MINIATURE CIRCUIT BREAKERS/ RCBO\"s/ RCCB\"s:MINIATURE CIRCUIT BREAKERS:Supply and erection of Miniature Circuit Breaker MCB\"s for circuit protection against overload and short circuit current fault suitable for 240/ 415 volts 50cycles AC supply with breaking capacity of 10kA, Curve-C and low watt losses as per IS/IEC 60898-1, energy limitation class-3, true contact indication, label holder facility in the existing MCB distribution board as per PWD General Specifications including connections with suitable size of thimbles/lugs:-MCB Single Pole 6-32amp. (10kA, Curve-C)[As per CSR Item no. 34.16 (A) (ii)] |
| 101 | RCBO\"s:RCBO\"s:Supply and erection of RCBO (Residual Current Breaker Overload) for Eart leakage, overload and short circuit protection suitable for 240/415 volts 50 cycles AC supply with breaking capacity of 10kA as per IEC 61009 in the existing MCB distribution board as per PWD General Specifications including connections with suitable size of thimbles/lugs:-RCBO Double Pole 63amp., Sensitivity 30mA[As per CSR Item no. 34.16 (B) (iv)] |
| 102 | SHEET METAL DOUBLE DOOR DISTRIBUTION BOARD FOR MCB\"s/ RCBO\"s/ RCCB\"s:Supply and erection of sheet metal Double Door Distribution Boards IP 43- IK09 metal door (dust protected) as per IS 8623-1&3, IEC 61439-1&3 suitable for flush mounting with fully insulated copper busbars, shrouded neutral bars, earth bars, cement spill protector, color coded interconnecting wire set, cable ties, blanking plates and circuit identifications label and of required no. of ways for mounting miniature circuit breakers/ RCBO\"s/ RCCB\"s in the distribution board (For SP&N distribution board with provision DP MCB\"s/ RCCB\"s/ RCBO\"s as incomer and SP MCB\"s as outgoings and for TP&N horizontal distribution board with provision TPN/ FP MCB\"s/ RCCB\"s/ RCBO\"s as incomer and SP MCB\"s as outgoings) as per PWD General specifications including connections with suitable size of thimbles and bonding to existing earth etc:-SP&N Double Door Distribution Board 12 way each.[As per CSR Item no. 34.17 (iii)] |
| 103 | PVC, HDPE PIPES & PVC FLEXIBLE PIPESSupply & erection of PVC Conduit Pipes (ISI marked) as per IS9537:Part-III & HDPE pipes (ISI marked) as per IS:4984:1995 for wiring purposes including bends, junction boxes, Steel hooks, M.S. saddle clamps and other petty materials etc., as per PWD General Specifications:-(x) Heavy Gauge PVC Conduit Pipe 25mm dia. (Flushed)[As per CSR Item no. 34.12 (iii)] |
| 104 | PVC INSULATED FR COPPER CONDUCTOR CABLESSupply and erection of PVC insulated FR single core Unsheathed copper conductor cable (ISI marked) suitable upto 1100 volts grade confirm to IS:694/1990 left bare in pipe or casing of suitable size complete in all respect as desired by the Engineer-in-charge:-[As per CSR Item no. 34.09 (i), (iii) & (iv)] Overall size 1sq.mm (Un-sheathed) |
| 105 | Overall size 2.5sq.mm (Un-sheathed) |
| 106 | Overall size 4sq.mm (Un-sheathed) |
| 107 | COPPER EARTHING:8 SWG COPPER EARTHING : Earthing with 8 SWG (4mm dia.)electrolytic copper wire thimbled (1No. copper thimble with suitable size steel bolt, washers & double nut) with 30cm x 60cm x 2mm thick copper plate (made cylindrical) buried below ground level in the hole of excavation having bore dia. 125mm and surrounded by salt & charcoal dust mixture (20 kg.) including fixing the copper wire run through 20mm dia. G.I. pipe (A-Class) recessed in wall and in floor etc., up to suitable Length in metre (including bore Length). G.I. pipe 20mm dia. (A-class) of suitable Length should be laid in the hole of excavation 1 feet below ground level and having GI Reducer 50mm x 20mm with PVC Cap (For pouring water) fixed on the top level of the pipe. 300mm x 300mm x 300mm deep haudi of First class bricks finished with 1:4 cement plaster and haudi covered with cast iron lid having size 300mm x 300mm (Heavy) around the hole of excavation:- (a) Earthing with 8 SWG (4mm dia.) copper wire thimbled with 30cm x 60cm x 2mm thick copper plate buried 4.50 metre (14.76 feet) below ground level (up to 8metre in Length) with G.I. pipe 20mm dia. (A-class), 3metre long[ As per CSR-2010 item No.34.14 (i)(a) ] |
| 108 | XLPE INSULATED UN-ARMOURED CABLES (ON SURFACE):Supply, laying and erection of aluminium conductor XLPE insulated PVC sheathed Un-armoured and served cable 1100 volts grade as per IS 7098 (Part-1)1988 to be laid (On Surface) as per PWD General Specifications:-Overall size 16sq.mm (2Core) Un-armoured (On-Surface).[ As per CSR-2010 item No. 34.10 ( c )(iii) ] |
| 109 | Providing and fixing LED Tube Light 36W (4feet) |
| 110 | Providing and fixing LED Bulb - 12 Watt |