Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, with piano type switch, phenolic laminated sheet, suitable size MS box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. |
| 2 | Group C |
| 3 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, with modular switch, modular plate, suitable Gl box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. |
| 4 | Group C |
| 5 | Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable and 1.5 sq.mm FRLS PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel/PVC conduit including dismantling as required. |
| 6 | Group C |
| 7 | Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. |
| 8 | 1 x 1.5 sq. mm |
| 9 | 3 x 1.5 sq. mm |
| 10 | 3 x 2.5 sq. mm |
| 11 | 3 x 4 sq. mm |
| 12 | 3 x 6 sq. mm |
| 13 | 6 x 6 sq. mm |
| 14 | 3 x 10 sq.mm. |
| 15 | 6 x 10 sq.mm. |
| 16 | 3 x 16 sq.mm. |
| 17 | 6 x 16 sq.mm. |
| 18 | 2 x 25 sq.mm. |
| 19 | Supply and drawing PVC insulated following round copper conductor cable of following sizefor connection ofequipment / exhaust fan etc as reqd. |
| 20 | 1.50 sq. mm , three core |
| 21 | 2.50 sq. mm , three core |
| 22 | 4.00 sq. mm , three core |
| 23 | 2.50 sq. mm , four core |
| 24 | 4.00 sq. mm , four core |
| 25 | Supplying and drawing 2 pair 0.5 mm dia FRLS PVC insulated annealed copper conductor, unarmored telephone cable in the existing surface/ recessed steel/ PVC conduit as required. |
| 26 | Supplying and fixing of following sizes of steel conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required. |
| 27 | 20 mm |
| 28 | 25 mm |
| 29 | 32 mm |
| 30 | 40 mm |
| 31 | S & F following size of PVC flexible pipe along with the accessories on surface etc as required. |
| 32 | 20 mm |
| 33 | 25 mm |
| 34 | Supply and fixing of 32 x 12.5 mm DLP mini- trunkingwhite-system with independent cover etc. as required complete. |
| 35 | Supply and fixing of following accessories suitable for 32 mm x 12.5 mm sizeplastic trunking white system. |
| 36 | End cap |
| 37 | Internal / external angle |
| 38 | Changeable flat angle |
| 39 | Flat junction |
| 40 | Supply and fixing of 32 x 20 mm DLP mini- trunkingwhite-system with independent coveretc. as required complete. |
| 41 | Supply and fixing of following accessories suitable for 32 mm x 20 mm sizeplastic trunking white system. |
| 42 | End cap |
| 43 | Internal / external angle |
| 44 | Changeable flat angle |
| 45 | Flat junction |
| 46 | Supply and fixing of 105 x 50 mm DLPtrunkingwhite-system but without cover and partition etc. as required complete. |
| 47 | Supply and fixing of following accessories suitable for 105 mm x 50 mm sizeplastic trunking white system. |
| 48 | 85 mm flexible cover |
| 49 | End cap |
| 50 | Internal angles- adjustable from 80°-100° |
| 51 | External angles- adjustable from 60°-120° |
| 52 | Flat junction |
| 53 | Flat angles |
| 54 | Separation partitions |
| 55 | Joints for 85mm width cover |
| 56 | Base joints |
| 57 | Supplying and fixing of 32 mm dia X 2.00 metres long G.l. pipe (medium class) bracket for mounting of fluorescent / FIPMV / HPSV street light fitting on pole including bending the pipe to the required shape, 2 nos 40 mm X 3 mm flat iron clamps with nuts, bolts and washer, painting the flat iron with primer and finish paint etc. as required. |
| 58 | Supply & Laying of32 mm dia, 8Kg / cm², minimum 2.0 mm thick HDPE pipe, ISI mark in following manners as required complete. |
| 59 | In ground I/c excavation, sand cushioning, protective covering and refixing the trench etc as reqd |
| 60 | In Pipe |
| 61 | On Surface |
| 62 | In open duct |
| 63 | Supply & Laying of40 mm dia, 8Kg / cm², minimum 2.0 mm thick HDPE pipe, ISI mark in following manners as required complete. |
| 64 | In ground I/c excavation, sand cushioning, protective covering and refixing the trench etc as reqd |
| 65 | In Pipe |
| 66 | On Surface |
| 67 | In open duct |
| 68 | Extra for cutting and drilling hole in down rod of 15mm dia GI pipe for ceiling fan etc. as required complete. |
| 69 | Supplying, fixing, painting of 15mm dia GI heavy class pipe down rod for ceiling fan etc as required complete. |
| 70 | S & F following size of steel flexible pipe along with the accessories on surface etc as required |
| 71 | 20 mm |
| 72 | 25 mm |
| 73 | 32 mm |
| 74 | 40 mm |
| 75 | Chemical Earthing with GI earth electrode 50 mm dia x 3 Mtr length with full GI strip including earth enhancing compound and RCC precast PIT cover and earthing pit etc as reqd. |
| 76 | Chemical Earthing with Copper bonded rod of copper coating of 250 microns of dia 25 mm, length 3 Mtr with clamp, including earth enhancement materialand RCC precast Pit cover and earthing pit etc as reqd. complete. |
| 77 | Earthing with G.l. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/coke and salt as required. |
| 78 | Earthing with G.l. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/coke and salt as required. |
| 79 | Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. (but without charcoal/ coke and salt ) as required. |
| 80 | Supplying and laying 25 mm X 5 mm G.l strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.l. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.l. nut bolt & spring washer spaced at 50mm) |
| 81 | Providing and fixing 25 mm X 5 mm copper strip in 40 mm dia G.l. pipe from earth electrode including connection with brass nut, bolt, spring, washer excavation and re-filling etc. as required. |
| 82 | Providing and fixing 25 mm X 5 mm copper strip on surface or in recess for connections etc. as required. |
| 83 | Providing and fixing 25 mm X 5 mm G.l. strip on surface or in recess for connections etc. as required. |
| 84 | Providing and fixing 6 SWG dia G.l. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/cable as required. |
| 85 | Supplying and fixing 20 A, 240 V, SPN Industrial type socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 A \"C\" curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required. |
| 86 | S & F rotary drive kit complete with handle and padlock facility for 125 amp MCCB etc. as reqd. |
| 87 | Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. |
| 88 | 125 A,36KA,FPMCCB |
| 89 | 200 A,36KA,FPMCCB |
| 90 | 250 A,36KA,FPMCCB |
| 91 | 400 A,50KA,FPMCCB |
| 92 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/lsolator) |
| 93 | 2+6 way, Double door |
| 94 | 2+8 way , Double door |
| 95 | 2+12 way, Double door |
| 96 | Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without |
| 97 | 4 way (4 +12), Double door |
| 98 | 6 way (4 +18), Double door |
| 99 | 8 way (4 + 24), Double door |
| 100 | Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer) as required . (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.) |
| 101 | 4 way (4 +12), Double door |
| 102 | 8 way (4 + 24), Double door |
| 103 | 12 way (4 + 36), Double door |
| 104 | Supplying and fixing following rating, 240/415 V, 10 kA, \"C\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 105 | Single pole 5 A to 32 A |
| 106 | Double pole 5 A to 32 A |
| 107 | Triple pole 5 A to 32 A |
| 108 | Triple pole and neutral 5 A to 32 A |
| 109 | Single Pole (40A-63A) |
| 110 | Double Pole (40A-63A) |
| 111 | Triple pole (40A-63A) |
| 112 | Four Pole (40A-63A) |
| 113 | Supplying and fixing following size/ modules, Gl box alongwith modular base & cover plate for modular switches in recess etc. as required. |
| 114 | 1 or 2 Module (75mmX75mm) |
| 115 | 3 Module (100mmX75mm) |
| 116 | 4 Module (125mmX75mm) |
| 117 | 6 Module (200mmX75mm) |
| 118 | 8 Module (125mmX125mm) |
| 119 | 12 Module (200mmX150mm) |
| 120 | Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point (without independent switch etc.) with 1.5 sq. mm ERLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit, and earthing the point with 1.5 sq. mm ERLS PVC insulated copper conductor single core cable etc. as required. |
| 121 | Group B |
| 122 | Group C |
| 123 | S&F connecting and commissioning independent mounting of MCCB enclosuresuitable for MCCB\"sup to 250A in surface/recess I/ccutting the wall and making good the same in case of recessed (Cat No CS-CNM0100021 C & S or approved equivalent make) as reqd. |
| 124 | S & F metal enclosure suitable for DP/TPNMCB / DP ELCB on surface or recessed etc as reqd. |
| 125 | Supply and fixing testing and commissioning of1X10 wattLED mirror light fixture with Electronicdriver, lamp, reflector, diffuser, MS body/housing holder etc. complete with all fixing accessories and lamp as required complete.(eq. To Cromptoncat. no. CCS-103-10-65-SL-DP-NWH). |
| 126 | Supply and fixing testing and commissioning of10 wattLED bulkhead fixture with Electronicdriver, lamp, reflector, diffuser, MS body/housing holder etc. complete with all fixing accessories and lamp as required complete.(eq. To Cromptoncat. no.LBHE-10-CDL |
| 127 | Supply of recessed mounted 3000 lm round shape fixed downlight fixture, pressure die-cast aluminium heat sink in white powder coated white finish, system lumen efficacy of 130 lm/W powered by electronic LED driver with output short circuit protection, surge protectionas required complete Philips make cat no. DN 394B LED 30S-6500 PSU WH or its equivalent approved make |
| 128 | Supply, installation, testing and commissioning offollowing LED lampin existing fitting as required complete. |
| 129 | 18 watt Tube LED lamp |
| 130 | 20 watt ESENTIAL PHILIPS or equivalent Tube in place of 36/40 W FL tube |
| 131 | 18 watt. LED PLL lamp |
| 132 | Supply and fixing of following LED light fixture with efficiency >100 lumen/ watt, P.F. >0.95, THD<10%,Electronic driver,LED lamp, reflector, diffuser, MS body/housing holder etc. complete with all fixing accessories and lamp as required complete. |
| 133 | 1 X 20W Box type LED tube with fitting |
| 134 | 2 X 20W Box type LED tube with fitting |
| 135 | 12 watt recess mounting LED light fixture |
| 136 | 12 watt surface mounting LED light fixture |
| 137 | 18 watt recess 300 x 300 mmmounting LED light fixture |
| 138 | 18 watt surface mounting 300 x 300 mm LED light fixture |
| 139 | 36 watt recess mounting LED light fixture 600 x 600 mm |
| 140 | 36 watt surface mounting LED light fixture 600 x600 mm |
| 141 | 36 watt recess mounting LED light fixture 300 x 1200 mm |
| 142 | 36 watt surface mounting LED light fixture 300 x 1200 mm |
| 143 | 20 watt batten type LED light fixture |
| 144 | 36/40 watt batten type LED light fixture |
| 145 | Supplying and fixing, following LED street light luminaries with pressure die cast aluminiumIP65 housing, driver etc. complete with all accessoriesas required. |
| 146 | 25 Watt LED street light luminaries |
| 147 | 45 Watt LED street light luminaries |
| 148 | Installation connacting, testing & commissioning all type fitting i/c dismantling form abnormal hight above 15\" to 35\" as reqd. |
| 149 | Alteration of internal wiring in existing fitting of any type for retrofitting of tube LED i/c dismantling & refixing as reqd. |
| 150 | Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required. |
| 151 | Supplying and fixing brass batten/ angle holder including connection etc. as required. |
| 152 | Supplying and fixing call bell/ buzzer suitable for single phase, 230 V, complete as required. |
| 153 | Installation, testing and commissioning of pre-wired, fluorescent fitting / compact fluorescent fitting of all types, complete with all accessories and tube/lamp etc. directly on ceiling/ wall, including connections with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required. |
| 154 | Supplying and fixing following piano type switch/ socket on the existing switch box/ cover including connections etc. as required. |
| 155 | 5/6 amps switch |
| 156 | 2 way 5/6 A switch |
| 157 | 15/16 A switch |
| 158 | 3 pin 5/6 A socket outlet |
| 159 | 6 pin 15/16 A socket outlet |
| 160 | Telephone socket outlet |
| 161 | Bell push |
| 162 | Fan regulator socket type |
| 163 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. |
| 164 | 5/6 A switch |
| 165 | 2 way 5/6 A switch |
| 166 | 15/16 A switch |
| 167 | 3 pin 5/6 A socket outlet |
| 168 | 6 pin 15/16 A socket outlet |
| 169 | Blanking Plate |
| 170 | Telephone socket outlet |
| 171 | Bell push |
| 172 | Two module stepped type electronic fan regulator |
| 173 | RJ 11 Telephone socket |
| 174 | Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required. |
| 175 | l or 2 Module |
| 176 | 3 Module |
| 177 | 4 Module |
| 178 | 6 Module |
| 179 | 8 Module |
| 180 | 12 Module |
| 181 | Supplying and fixing following size/ modules, plastic boxfor modular switches in recess etc as required. |
| 182 | 1 or 2 Module |
| 183 | 3 Module |
| 184 | 4 Module |
| 185 | 6 Module |
| 186 | 8 Module |
| 187 | 12 Module |
| 188 | Providing connection for motor/ panel starter/ transformer up to 1 Keva / stabilizer. |
| 189 | Supply fixing connecting & commissioning of 5 Amp rating ISI marked 3 pin Plug top Anchor make as reqd complete. |
| 190 | Supply fixing connecting & commissioning of 15 Amp rating ISI marked 3 pin Plug top Anchor make as reqd complete. |
| 191 | Supply and Fixing, 20 Amp. Plug top for 2P+E industrial socket and top assembly as required complete. |
| 192 | Supply and Fixing, 20 Amp. socket for 2P+E industrial socket and top assembly as required complete. |
| 193 | Fixing of RJ-45 modular box with cover plate or I/o box for interneton surface/ recessed cutting the wall making good the same as required. ( box and cover plate will be supplied by dept.) |
| 194 | Laying of1/2/3 run of UTP cable enhanced cat 5/cat 6 cable in existing steel conduit pipe/GI pipe/ raceway / RCC pipe as reqd. the cost shall also include numbering of networking wire from room to rack as reqd. (wire will be supplied by dept) |
| 195 | Installation of exhaust fan Upto 450 mm sweep in the existing opening, including making good the damage, connection, testing, commissioning etc. as required. |
| 196 | S & F fan hook I/c cutting the slab and fixing with the reinforcement and making damage, painting etc as the same |
| 197 | Supplying and fixingInformation Socket - RJ45 -CAT 6 - UTP - tooless with shutter - 1 Module cat. 6792 65 Legrand make on the existing modular sheet as required complete. |
| 198 | Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CM/M/W) minimum 6.00, Air delivery minimum 210 Cum/Min, 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required. |
| 199 | Supply, Installation testing and commissioning of following seep, copper wound, 900 RPM, 220 volt AC, 50 Hz exhaust fan in the existing openingetc as required complete. |
| 200 | 300 mm / 12\" sweep |
| 201 | 375 mm / 15\" sweep |
| 202 | 450 mm / 18\" sweep |
| 203 | 600 mm / 24\" sweep |
| 204 | Supplying and fixing exhaust fan shutter for following sizes exhaust fan on rag bolts as reqd complete. |
| 205 | for 300 mm / 12\" sweep |
| 206 | for 375 mm / 15\" sweep |
| 207 | for 450 mm / 18\" sweep |
| 208 | for 600 mm / 24\" sweep |
| 209 | Supply and installation of 400mm sweep AC 230/250 volts, 50 Hz wall mounting revolving fan with brackets etc complete. |
| 210 | Supplying and fixing connecting and commissioning of AC230/250 volts, 50 HZ, 250 mm sweep fresh air fanincluding providingnuts, bolts, mounting frame and other accessories etc.complete |
| 211 | Supply, Fixing, wall mounting air circulator fan 450 mmCrompton make or equivalent make as reqd |
| 212 | S&F, Copper tube / reducer/ lugterminals suitable for following size of conductor. |
| 213 | 6 /10/16 Sq.mm. |
| 214 | 25/35/50 Sq.mm. |
| 215 | Supplying and laying of one no. 2 x 10.0 sqmm PVC insulated, XLPE steel armoured aluminium conductor power cable of grade 1.1 kVas required complete in following manners. |
| 216 | in ground I/c excavation, sand cushioning, protective covering and refixing the trench etc as reqd |
| 217 | In Pipe |
| 218 | In open duct |
| 219 | On Surface |
| 220 | Supplying and laying of one no. 4 x 16.0 sqmm PVC insulated, XLPE steel armoured aluminium conductor power cable of grade 1.1 kVas required complete in following manners. |
| 221 | in ground I/c excavation, sand cushioning, protective covering and refixing the trench etc as reqd |
| 222 | In Pipe |
| 223 | In open duct |
| 224 | On Surface |
| 225 | Supplying and laying of one no. 3.5 x25.0 sqmm PVC insulated, XLPE steel armoured aluminium conductor power cable of grade 1.1 kVas required complete in following manners. |
| 226 | In ground I/c excavation, sand cushioning, protective covering and refixing the trench etc as reqd |
| 227 | In Pipe |
| 228 | In open duct |
| 229 | On Surface |
| 230 | Supplying and laying of one no. 3.5 x35.0 sqmm PVC insulated, XLPE steel armoured aluminium conductor power cable of grade 1.1 kVas required complete in following manners. |
| 231 | In ground I/c excavation, sand cushioning, protective covering and refixing the trench etc as reqd |
| 232 | In Pipe |
| 233 | In open duct |
| 234 | On Surface |
| 235 | Supplying and laying of one no. 3.5 x50.0 sqmm PVC insulated, XLPE steel armoured aluminium conductor power cable of grade 1.1 kVas required complete in following manners. |
| 236 | In ground I/c excavation, sand cushioning, protective covering and refixing the trench etc as reqd |
| 237 | In Pipe |
| 238 | In open duct |
| 239 | On Surface |
| 240 | Lifting removing cable of following size from trench/clamps, making roll & depositing the same in store I/c cartage. |
| 241 | Up to 35 Sq.mm. |
| 242 | Above 35up to 95 Sq.mm. |
| 243 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. |
| 244 | Upto 35 sq. mm |
| 245 | Above 35 sq. mm and upto 95 sq. mm |
| 246 | Above 95 sq. mm and upto 185 sq. mm |
| 247 | Above 185 sq. mm and upto 400 sq. mm |
| 248 | Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required. |
| 249 | Upto 35 sq. mm (clamped with 1mm thick saddle) |
| 250 | Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm MS flat clamp) |
| 251 | Above 95 sq. mm and upto 185 sq. mm (clamped with 25/40x3mm MS flat clamp) |
| 252 | Above 185 sq. mm and upto 400 sq. mm (clamped with 40x3mm MS flat clamp) |
| 253 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required. |
| 254 | Upto 35 sq. mm |
| 255 | Above 35 sq. mm and upto 95 sq. mm |
| 256 | Above 95 sq. mm and upto 185 sq. mm |
| 257 | Above 185 sq. mm and upto 400 sq. mm |
| 258 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing masonry open duct as required. |
| 259 | Upto 35 sq. mm |
| 260 | Above 35 sq. mm and upto 95 sq. mm |
| 261 | Above 95 sq. mm and upto 185 sq. mm |
| 262 | Above 185 sq. mm and upto 400 sq. mm |
| 263 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. |
| 264 | 2 X10 sq. mm (19mm) |
| 265 | 2 X16 sq. mm (22mm) |
| 266 | 3½ X 25 sq. mm (28mm) |
| 267 | 3½ X 35 sq. mm (32mm) |
| 268 | 3½ X 50 sq. mm (35mm) |
| 269 | 3½ X 70 sq. mm (38mm) |
| 270 | 3½ X 95 sq. mm (45mm) |
| 271 | 3½ X120 sq. mm (45mm) |
| 272 | 3½ X 150 sq. mm (50mm) |
| 273 | 3½ X 185 sq. mm (57mm) |
| 274 | 3½ X 300 sq. mm (70mm) |
| 275 | 3½ X 400 sq. mm (82mm) |
| 276 | 4 X 16 sq. mm (28mm) |
| 277 | Supplying and making straight through joint with heat shrinkable kit including ferrules and other jointing materials for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. |
| 278 | 2X16 sq.mm |
| 279 | 3½ X 25 sq. mm |
| 280 | 3½ X 35 sq. mm |
| 281 | 3½ X 50 sq. mm |
| 282 | 3½ X 70 sq. mm |
| 283 | 3½ X 95 sq. mm |
| 284 | 3½ X 120 sq. mm |
| 285 | 3½ X 185 sq.mm |
| 286 | 3½ X 240 sq. mm |
| 287 | 3½ X 300 sq. mm |
| 288 | 3½X400 sq. mm |
| 289 | 4 X 16 sq. mm |
| 290 | Dismantling & refixing brass compression type cable gland up to size400 sq.mm. cable. |
| 291 | Dismantling the old conduit pipe/wood batten of all sizes from surface/recessed & making good the damages I/c filling the holes of the surface etc as reqd. and depositing itin sectional store. |
| 292 | Dismantling concealed & damaged DB/TPN Switches/starter/ loose wire boxes along with all accessories and depositing the same in the sectional store repairing the damages asreqd complete. |
| 293 | Dismantling and refixing of M.S./PVC box of up to 250 x 300 x100on surface recessed as required. including painting with enamel paint as reqd |
| 294 | Fixing ofNetwork rack on steel fastener including cartage from store to site as reqd complete. |
| 295 | Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc. as required. |
| 296 | Dismantling, disconnecting old damaged unserviceable fl fitting/ exhaust fan/ ceiling fan/ bulkhead fitting with bracket etc. as reqd. and depositing in sectional store. |
| 297 | Fixing 20/25/32 mm conduit pipe/ DLP on surface with clamp/in recessed only conduit pipe supplied by department.(Free of cost) |
| 298 | Supplying and fixing following rating MCB type changeover switchsuitable for inductive load of following poles in the existing MCB DB/enclosure complete with connections, testing and commissioning etc as reqd. |
| 299 | 25 Amp, Double pole |
| 300 | 63 Amp, double pole |
| 301 | 63 Amp, Four pole |
| 302 | S & F, connecting and commissioning 4 pole Front handle operated in sheet steel enclosure On Load changeover switch of following capacity etc. as reqd. |
| 303 | 125 Amp |
| 304 | 160 Amp |
| 305 | Fixing 100 A to 630 ATPN switch / MCCB /Changeover switch on existing frame / board i/c providing nut and bolts with washer etc. as reqd. |
| 306 | S & F bakelite sheet 6 mm thick complete with required nuts & bolts as reqd. |
| 307 | Supplying & fixing3mm (1/8\") thick phenolic laminated sheet on existing board with screw & washer etc. as required. |
| 308 | Locating fault in the cable lines with meggar etc and rectifying removing & restoring the same and making good the damages etc as required. |
| 309 | Locating fault in wiring rectifyingremoving &restoring supply the same & making good the damages etc as reqd. |
| 310 | Digging cable trench, lifting brick & cable for locating fault and relaying the cable i/c refilling the trench, extra sand if required shall be i/c in the item of following size.as required. |
| 311 | Up to 35 Sq.mm. |
| 312 | Above 35up to 95 Sq.mm. |
| 313 | Above to 95up to 185 Sq.mm. |
| 314 | Supplying,installation,testing and commissioning of Astronomical time switch of 2 output per phase and suitable for single phase supply to be mounted in feeder pillars / Lighting DBs for automatic switching On & OFF of street lights at sun set & sun rise or twilight(Auto ON, Auto OFF, Auto modes) with manual override facility with 12/24 hour display format with suitable battery and indication for relay status i/c programming at site complete as required. |
| 315 | P&F, connecting and commissioning of surface mounted timer switchfor 24 hrs. setting & fixingin the existing enclosure complete with connections, testing and commissioning etc as reqd. |
| 316 | Supplying & fixingConnecting , testing & commissioning, direct online starter suitable for up to 10.0 HP 3 phase induction motor 415V, 50Hz as required complete. Cat no. SS94351 L&T or it\"s equivalent approved make as required complete. |
| 317 | Supplying, installation, testing & commissioning sector panel suitable for following zones, complete with visual indications for short circuit fault, open circuit fault, fire condition and all other standard facilities as per IS:2189 with mimic diagram for all area/zone covered, complete with all connections, interconnections as required. |
| 318 | 4 Zone |
| 319 | 6 Zone |
| 320 | 10 Zone |
| 321 | Supplying, installation, testing & commissioning of smoke detector with builtin LED and mounting base complete with all connections etc. as required. |
| 322 | Supplying, installation, testing & commissioning of manual call box of ABS type in surface/recess with stainless steel chain & hammer assembly complete with glass and push button etc. as required. |
| 323 | Supplying, installation, testing & commissioning fire alarm sounder with facility to make announcement, mounted in A.B.S. box with hinged cover plate & suitable for operation with amplifier i/c line matching transformer etc. complete as required. |
| 324 | Supplying, installation, testing & commissioning response indicator on surface/recess MS box having two LEDs metallic cover complete with all connections etc. as required. |
| 325 | Supplying and fixing 32 amps, 230 volts, 2P+E industrial type, socket outlet, with 3 pin metal enclosed plug top along with 32 amps \" C \" series double pole MCB, in the sheet steel enclosure, on surface or in recess, with chained metal cover for the socketas required complete. |
| 326 | Supplying and fixing 32 amps, 415 volts, 3P+N+E industrial type, socket outlet, with 5 pin metal enclosed plug top along with 32 amps \" C \" series four pole MCB, in the sheet steel enclosure, on surface or in recess, with chained metal cover for the socket as required complete. |
| 327 | Supplying and fixing 63 amps, 415 volts, 3P+N+E industrial type, socket outlet, with 5 pin metal enclosed plug top along with 63 amps \" C \" series four pole MCB, in the sheet steel enclosure, on surface or in recess, with chained metal cover for the socket as required complete. |
| 328 | Supplying and fixing following modular switch/ socket on the existing clip-on frame fixed on 85mm cover of 105 x 50 mm DLP plastic trunking including connections etc. as required complete. |
| 329 | 6 A switch |
| 330 | 20 A switch |
| 331 | 6 A pin 2/3 pin socket outlet |
| 332 | 6/16 A 3 pin socket outlet |
| 333 | Supplying, installation of Clip-on frame with finishing plate for 85mm cover for DLP plastic trunking 105mm x 50mmetc. as reqd. |
| 334 | 2 module |
| 335 | 3 module |
| 336 | 4 module |
| 337 | 6 module |
| 338 | Unit for 2 modules can be fitted together |
| 339 | Supplying and fixing Infrared sensors 400 W 2 module suitable for following Lighting complete with connections, testing and commissioning etc. as required. |
| 340 | Supplying and installing following size of perforated painted with powder coating M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required. |
| 341 | 150 mm width X 50 mm depth X 1.6 mm thickness |
| 342 | 300 mm width X 50 mm depth X 1.6 mm thickness |
| 343 | S&F, connecting and commissioning looping type cable end control box with MS sheet of 16 SWG of size 200 mm x 200 mm x 125 mm having 1 no. 6amp to 32 amp SPMCB 250 volt and 2 nos. brass neutral link 12.5 mmsquare rod 6 way approx. 60 mm long and fixed on 6 mm thick bakelite sheet. Box shall have almirah type hinge and panel key type lock front door duly painted with earthing stud etc. complete as required. |
| 344 | Providing, laying and fixing following dia G.l. pipe (medium class) in ground complete with G.l. fittings including trenching (75 cm deep)and re-filling etc as required |
| 345 | 50 mm dia |
| 346 | 65 mm dia |
| 347 | 80 mm dia |
| 348 | 100 mm dia |
| 349 | Supplying and drawing of UTP (24 AWG) 4 pair CAT 6 LAN Cable in the existing surface/ recessed Steel/ PVC conduit as required. |
| 350 | 1 run of cable |
| 351 | 2 run of cable |
| 352 | 3 run of cable |
| 353 | Supplying and fixing metal box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc. as required. |
| 354 | 100 mm X 100 mm X 60 mm deep |
| 355 | 180 mm X 100 mm X 60 mm deep |
| 356 | 200 mm X 150 mm X 60 mm deep |
| 357 | 200 mm X 250 mm X 60 mm deep |
| 358 | Supplying and laying of one no. 3.5 x70.0 sqmm PVC insulated, XLPE steel armoured aluminium conductor power cable of grade 1.1 kVas required complete in following manners. |
| 359 | In ground I/c excavation, sand cushioning, protective covering and refixing the trench etc as reqd |
| 360 | In Pipe |
| 361 | In open duct |
| 362 | On Surface |
| 363 | Supplying and laying of one no. 3.5 x95.0 sqmm PVC insulated, XLPE steel armoured aluminium conductor power cable of grade 1.1 kVas required complete in following manners. |
| 364 | In ground I/c excavation, sand cushioning, protective covering and refixing the trench etc as reqd |
| 365 | In Pipe |
| 366 | In open duct |
| 367 | On Surface |
| 368 | Supplying and laying of one no. 3.5 x120.0 sqmm PVC insulated, XLPE steel armoured aluminium conductor power cable of grade 1.1 kVas required complete in following manners. |
| 369 | In ground I/c excavation, sand cushioning, protective covering and refixing the trench etc as reqd |
| 370 | In Pipe |
| 371 | In open duct |
| 372 | On Surface |
| 373 | Supplying and laying of one no. 3.5 x150.0 sqmm PVC insulated, XLPE steel armoured aluminium conductor power cable of grade 1.1 kVas required complete in following manners. |
| 374 | In ground I/c excavation, sand cushioning, protective covering and refixing the trench etc as reqd |
| 375 | In Pipe |
| 376 | In open duct |
| 377 | On Surface |
| 378 | Supplying and laying of one no. 3.5 x185.0 sqmm PVC insulated, XLPE steel armoured aluminium conductor power cable of grade 1.1 kVas required complete in following manners. |
| 379 | In ground I/c excavation, sand cushioning, protective covering and refixing the trench etc as reqd |
| 380 | In Pipe |
| 381 | In open duct |
| 382 | On Surface |
| 383 | Supplying and laying of one no. 3.5 x300.0 sqmm PVC insulated, XLPE steel armoured aluminium conductor power cable of grade 1.1 kVas required complete in following manners. |
| 384 | In ground I/c excavation, sand cushioning, protective covering and refixing the trench etc as reqd |
| 385 | In Pipe |
| 386 | In open duct |
| 387 | On Surface |
| 388 | Supplying and laying of one no. 3.5 x400.0 sqmm PVC insulated, XLPE steel armoured aluminium conductor power cable of grade 1.1 kVas required complete in following manners. |
| 389 | In ground I/c excavation, sand cushioning, protective covering and refixing the trench etc as reqd |
| 390 | In Pipe |
| 391 | In open duct |
| 392 | On Surface |
| 393 | Overhauling of ceiling fan of any sizeincluding dismantling and refixing of fan, bearings, checking, cleaning the all parts and supply & replacement of rubber real, rubber rings, nut bolts, hanger clamps, bearing plates, cotter/ split pin, varnishing if reqdetc, reassemblingtesting and commissioning of fan as required complete. |
| 394 | Dismantling, refixing, testing and commissioning of any size fan from normal height (Up to 3.5 Mtr.) as required complete. |
| 395 | Cleaning of ceiling fan with detergent at site etc as required. |
| 396 | Supplying and fixing following capacity capacitor suitable for ceiling fan / exhaust fan / air-curtain etc.. |
| 397 | 2.5 mfd |
| 398 | 4.0 Mfd |
| 399 | Rewinding of ceiling fans of following sizes i/c dismantling of rotor cutting the damaged winding and providing rewinding along with insulation paper, varnish, connecting copper leads of suitable quality including dismantling and refixing from normal/abnormal height and refixing as required. |
| 400 | New Model 1200 mm |
| 401 | Old Model 1200 mm / New Model 1400mm |
| 402 | Dismantling& disconnecting and refixing of exhaust fan from 12\" to 24 \" size with required nut bolts, fasteners, rag bolts etc. as required. |
| 403 | Overhauling of exhaust fan of any size including dismantling of all parts and cleaning the fan with Diesel / petrol removing ball bearing/ bush and refixing after greasing/ oiling including testing and commissioning as required complete. |
| 404 | Repairing of housing for bearing side /bush side /in fan body in ceiling fan /exhaust fan /rally fan etc. |
| 405 | Rewinding of exhaust fans of following sizes i/c dismantling cutting the damaged winding and providing rewinding along with insulation paper, varnish, connecting copper leads of suitable quality including dismantling and refixing from normal/abnormal height and refixing as required.( old burnt wire shall be retain by the contactor.) |
| 406 | Rewinding of exhaust fan12\" |
| 407 | Rewinding of exhaust fan15\" |
| 408 | Rewinding of exhaust fan 18\" |
| 409 | Carriage of Ceiling fan and regulator / exhaust fan from store to site as reqd. |
| 410 | Fabricating, supplying & fixing of box of required size and shapemade out of 2mm thick CRCA sheet duly powder coated, Locable & openable from or front, top or bottomas required complete. |
| 411 | Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required. |
| 412 | Supply Installation, testing and commissioning of following ceiling fan, including wiring the down rods of standard length (up to 30 cm) with 1.5 sq. mm FR PVC insulated, copper conductor, single core cable etc. as required. |
| 413 | 1200mm sweep. |
| 414 | Supplying, fixing testing and commissioning of following ways, surface/ recess mounting, vertical type, 415 volts, TPN distribution board of sheet steel, dust protected, duly powder painted, inclusive of 160/250 amps tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCB\"s (but without MCB\"s and incomer ) as required complete. |
| 415 | 8 way , Double door, with provision of 160 A MCCB as incommer |
| 416 | 8 way , Double door, with provision of 250 A MCCB as incommer |
| 417 | 12 way , Double door, with provision of 160 A MCCB as incommer |
| 418 | 12 way , Double door, with provision of 250 A MCCB as incommer |
| 419 | S & F, connecting and commissioningof following contactor in existing enclosure including drilling holes making thread/ nut bolts etc. as required complete. |
| 420 | 3 pole AC 3 rating 32 A (MNX32) |
| 421 | 3 pole AC 3 rating 110 A (MNX110) |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail