| 1 | New Electrification Work at MEC104(Physical Metallurgy Lab) of New Metallurgical and Materials Engineering Department in V.N.I.T. Campus, Nagpur. |
| 2 | Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 16 sq. mm. copper conductor complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/CU |
| 3 | Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 10 sq. mm. copper conductor complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipeas per specification no. CB-LT/CU |
| 4 | Supplying & erecting triple pole and neutral distribution board (TPNDB), SPMCB of 4 ways/phase (12 poles), with door, 1.2mm thickness, surface/flush mounted, IP 43 protection on provided iron/GI frame (horizontal busbar type) as per specification no.SW-MCBDB. |
| 5 | Supplying and erecting iron work,purpose with bending, cutting, drilling and welding complete erected at the position with necessary materials duly painted with one coat of red oxide and two coats of enamel paint to match the switchgears or as per directions by the site engineer. |
| 6 | Supplying, erecting & commissioning 4 pole RCCB 63A, electromagnetic type with 30/100/300 mA sensitivity with earth leakage trip indication complete as per specification no. SW-RCCB. |
| 7 | Supplying, erecting & marking FP MCB 40A to 63A, with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-MCB |
| 8 | Supplying, erecting & marking FP MCB 6A to 32A, with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-MCB |
| 9 | Supplying, erecting & marking DP MCB 6A to 32A, C-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no.SW-MCB |
| 10 | Supplying, erecting & marking SP MCB 6A to 32A, C-series with rated short - circuitbreaking capacity (Icn) 10kA in provided distribution board as per specification no.SW-MCB |
| 11 | Supplying, erecting & marking SP MCB 6A to 32A, B-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-MCB |
| 12 | Supplying & erecting CRCA sheet metal one way enclosures of 1.2mm thickness suitable for DP MCB/TP MCB/FP MCB/RCCB/RCBO complete erected on provided angle iron/GI frame. |
| 13 | Supplying, erecting, testing & commisioning plywood 12 mm thick fixed to wall or on provided panel board with necessary materials such as screws, wall fasteners supports, nuts bolts etc. complete as per specification no. CP/SH/CR |
| 14 | Supplying and erecting modular type D.P. switch 32A with indicator on provided plate and box with wiring connections complete. |
| 15 | Supplying and erecting PVC Surface modular switch box with double mounting plate for 2 module complete |
| 16 | Supplying and erecting PVC Surface modular switch box with double mounting plate for 4 module complete. |
| 17 | Supplying and erecting PVC Surface modular switch box with double mounting plate for 6 module complete |
| 18 | Supplying and erecting PVC Surface modular switch box with double mounting & front plate for 8 module complete duly connected. |
| 19 | Supplying and erecting PVC Surface modular switch box with double mounting plate for 12 module complete |
| 20 | Supplying and erecting PVC Surface modular switch box with doublemounting plate for 16/18 module complete |
| 21 | Supplying and erecting modular type switch 6A/10A on provided plate and box with wiring connections complete. |
| 22 | Supplying and erecting modular type 3 pin 6/16A multi socket with safety shutter on provided plate and box with wiring connections complete. |
| 23 | Supplying and erecting modular type switch 16A on provided plate and box with wiring connections complete. |
| 24 | Supplying and erecting modular type switch 16/20 A with indicator on provided plate and box with wiring connections complete. |
| 25 | Supplying and erecting modular type blanking plate one module, on provided plate & box |
| 26 | Supplying and erecting blanking plate of suitable size on MCBDB |
| 27 | Point wiring for light/bell hybrid type (surface type under false ceiling and concealed type for drops & switch boards on walls) in min 20 mm HMS PVC conduit / casing n capping with 1.5 sq.mm. (2+1E) FRLSH grade copper wires, modular type switch, earthing and required accessories as per specification no. WG-HW |
| 28 | Point wiring for ceiling fan hybrid type (surface type under false ceiling and concealed type for drops & switch boards on walls) in min 20 mm HMS PVC conduit / casing n caping with 1.5 sq.mm. (2+1E) FRLSH grade copper wires,modular type switch, earthing and required accessories as per specification no.WG-HW |
| 29 | Point wiring for light/bell/exhaust fan in PVC trunking (casing-capping) with 1.5 sq.mm (2+1E) FRLSH grade copper wire, modular type switch, earthing and required accessories as per specification no. WG-PW/SW |
| 30 | Point wiring for ceiling fan in PVC trunking (casing-capping) with 1.5 sq.mm (2+1E) FRLSH grade copper wire, modular type switch, earthing and required accessories as per specification no. WG-PW/SW |
| 31 | Wiring for plug on board with switch socket surface /concealed type, copper wiring and earthing and with modular accessories as per specification no. WGPW/ CW |
| 32 | Supplying & erecting mains with 2x4 sq.mm FRLSH copper PVC insulated wire laid in provided conduit /trunking/inside pole/bus bars or any other places. as per specification no. WG-MA/BW |
| 33 | Supplying & erecting mains with 2x2.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/ inside pole/bus bars or any other places. as per specification no. WG-MA/BW |
| 34 | Supplying & erecting mains with 2x1.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit /trunking/ inside pole/bus bars or any other places as per specification no. WG-MA/BW |
| 35 | Supplying and erecting HMS PVC conduit 25mm dia. with PVC accessories on wall/ceiling as per specification no. WG-MA/CON. |
| 36 | Supplying and erecting HMS PVC conduit 32mm dia. with PVC accessories on wall/ceiling as per specification no. WG-MA/CON. |
| 37 | Supplying and erecting PVC trunking (PVC casing-n-capping) of size 25mm with accessories on wall/ceiling as per specification no. WG-MA/CON. |
| 38 | Supplying and erecting PVC trunking (PVC casing-n-capping) of size 32mm with accessories on wall/ceiling as per specification no. WG-MA/CON. |
| 39 | Supplying and erecting PVC trunking (PVC casing-n-capping) of size 60mm with accessories on wall/ceiling as per specification no. WG-MA/CON. |
| 40 | Supplying and erecting 25mm dia. corrugated flexible polypropylene conduit |
| 41 | Supplying and erecting LED square / circular Max. 18 W down lighter / Panel Light having pressure die-cast aluminium housing, polystyrene diffuser having system lumens output of Min. 2000 Lumens, min. efficacy of 110 lumen/W, CRI>80, CCT upto 6500K, Beam Angle of 120 deg., max. ripple of 5%, THD<10%, p.f. >0.95, operating range of 120-270V, surge protection of 2.5 kV, Life class of 50,000 Hrs at L70B0 including driver, having mounting arrangement with board for surface type or spring loaded mounting clips complete with minimum 2 years warranty as per specification No. FG-IDF/LED and must be compatible |
| 42 | Supplying and erecting LED square / circular Max. 14 W down lighter / Panel Light having pressure die-cast aluminium housing, polystyrene diffuser having system lumens output of Min. 1500 Lumens, min. efficacy of 110 lumen/W, CRI>80, CCT upto 6500K, Beam Angle of 120 deg., max. ripple of 5%, THD<10%, p.f. >0.95, operating range of 120-270V, surge protection of 2.5 kV, Life class of 50,000 Hrs at L70B50 including driver, having mounting arrangement with board for surface type or spring loaded mounting clips complete with minimum 2 years warranty as per specification No. FG-IDF/LED. |
| 43 | Supplying and erecting regular/ standard model ceiling fan of 1200mm. Sweep complete erected in position as per specification no. FG-FN/CF |
| 44 | Supplying and erecting modular type (two module) electronic step regulator for fan, on provided plate and box with wiring connections complete. |
| 45 | Supplying and erecting โBโ grade G.I. pipe / M.S. pipe down rod duly painted for fan complete erected with PVC three core flexible cable 1 sq. mm copper PVC wire. |
| 46 | Supplying & erecting crimping type copper lugs for cable upto 16 sq mm completeas per specification No. CB-CL/CU |
| 47 | Dismantling the existing light, switch boards,TPNDB/SPNDB, detachable gland plate , Iron pipes independent plug point, wiring including circuit mains of all types along with all accessories and filling of holes with POP etc. complete as per specification no. WG-DM/PW(approximate total area of the work site is 100 sq.mtr.) |