| 1 | Note :(i) Please refer Sch A/ BOQ Notes before quoting the tender for all phases/ items mentioned below.(ii) Amount of Schedule of credit shall be deducted offline |
| 2 | M&L for 10mm thick cement plaster over PCC in CM 1:4 finished even and smooth without using extra cement and using WPC of approved make as per manufacturers instruction upto 10 meter height complete all as specified and directedNote:- WPC shall be measured and paid separately. |
| 3 | M&L for priming surfaces withapplying evenly a tack coat of hot industrial bitumen VG-10 grade at the rate of 1.2 kg per sqm including cleaning of newly plastered surface complete all as specified and directed |
| 4 | M&L for applying APP based polymeric membrane minimum weighing 3kg/sqm and minimum 3mm thick reinforced with polyster non woven fabric (wt. not less than 150 gms/sqm) laid on primed surface by using fire torching with forced application including taking down old APP membrane and preapare surfacescomplete all as specified |
| 5 | M&L for preparation of newly fixed APP surfaces and evenly applying with roller brush two coat of aluminum paint complete all as specified and directed. |
| 6 | M&L for preparation of newly plastered or unplastered existing roof surface by washing rubbing down removing dirt, algae moss, fungal growth or vegitation etc. and applying approved chemical treatment to roof/ exterior wall/ parapet wall/ chhajjas and any other position as per site requirement complete all as specified and as directed in following steps:- Step-1Opening of sealed container and dilute the chemical with water @ 1:3 using mechanical mixer to prepare primer and apply one coat of primer using roller and allow 4-6 hrs to dry for primer.Step-2 Apply two coats of approved chemical roof treatment with roller to primed surface as per manufacturer\"s instruction and allow 4-6 hrs to dry treatment.Note :-Removal of old roof treatment work and plastering to floor / wall surface will be measuered and paid saperately.Make:- Asian Smart Care Damp Proof / Berger Weather Coat Roof Guard / Nerolac Perma No Damp |
| 7 | M&L for preparing and applying Dr. Fixit rain coat on external walls in comprising following steps:-(1) Existing substrates cleaned and removed all scale dirt, algea moss, fungal growth etc on new/ old surface using mechanical vaccum wall sander (having RPM not less than 1500) sanding pad of 80 grit of dia 7\"/ 9\"on walls (external surface). The surface shall be made dry completely for upto 4-6 days for application of primer.(2) Applying one coat primer Dr. Fixit rain coat diluted with 2:1 with water (chemical:water) maintaining spreading rate @ 8 to 10 sqm / ltr. (3) Applying two coats of Dr Fixit raincoat without any dilution for coverage 3.5 sqm/ltr andsecond coat of Dr. fixit rain coat without any dilution for coverage 7 sqm/ltr complete all as specified and directed.Note :- (i) Second coat must be applied after lapse of 6 to 8 hours application of first coat.(ii) The application of Dr Fixit raincoat must be avoided at temperature below 10˚C more than 35˚C and in direct sunlight. |
| 8 | Supply & fix aluminium snap grid frame work of size 605x605mm for false ceiling comprising 36X25X2 mm aluminium angle fixed along wall at ends and with aluminium angle cross section 35X25X1.4 mm at middle including drilling holes in wall for fixing angle etc. including 3 mm GI wire hangar complete all as specified and directed. |
| 9 | S&F for exposed metal frame ceiling with 6 mm thick PVC coated calcium silicate board of siliceous and calcareous material reinforced with cellulose fibre for fixing in 600 mm x 600mm grid complete all as specified and directed.Note:- Frame work for ceiling shall be measured and paid separately. |
| 10 | S&F Gl frame work for seamless ceiling comprising of Gl perimeter channnel 0.55 mm thick with two unequal flanges of 20 and 30 mm and web of 27 mm fixed to surrounding wall using nylon sleeves and screws at 450 mm centre to centre /intermediate channel 0.9 mm thick having two equal flanges of 15 mm each and web of 45 mm suspended from soffit at approx 900 mm centre to centre with Gl cleat and steel expansion fasteners with and including ceiling section (not exc 1.2 m length) of 0.55 mm thickness having kurled web of 50 mm and flange of 26 mm each with lips of 10.5 mm fixed to the intermediate channel with connecting clips across the intermediate channel at 457 mm centre to centreincluding hangers 3 mm dia. G.I. (upto 1200mm length) adjusting level fixed to roof slabs by means of ceilling cleats made out of G.I. flat 40 x 3 mm size 60mm long and expansion hold fasteners 12.5mm dia. 40mm longcomplete all as specified and directed. |
| 11 | S&F for providing and fixing gypsum board 12mm thick in ceiling fixed with screw as per manufacturers instructions including two coats of oil bound distemper on gypsum board complete all as specified and directed. |
| 12 | S&F Steel work in tubular trusses including special shaped washer etc complete using ERW or induction butt welded tubes conforming to IS-1161-1979 Grade St-240 including dismantling of old steel fixed in any position and of and size complete all as specified and directed |
| 13 | Excavating in post holes (or similar holes) each n exc 0.5 cu. m, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm each in hard dense soil complete all as specified and directed. |
| 14 | S&F Pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50 mm thick ( AZ 150 ) of approved colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws and bitumen washer including dismantling of old sheets fixed at any location complete all as specified and directed. |
| 15 | All as per ser item no 13.00 here-in-before butof plain sheet in ridges, hips, valley gutter, drip and straight flashing (length and girth as fixed)including dismantling of old sheets fixed at any location complete all as specified and directed. |
| 16 | M&L for PCC (1:3:6) type C-2 using 40 mm graded aggregate as in post hole complete all as specified and directed. |
| 17 | M&L Providing, cement concrete 1:2:4 type B1 using 20 mm gradded stone aggregate in lintels upto 1.5m clear span, cills, steps; copings, kerbs, water troughs and the like including weathering, slightly rounded or chamfered angles and throating, as directed including neccessary formwork. |
| 18 | Demolition of brick work, built in cement mortar including all quoins, arches, pillars etc complete all as specified and directed. |
| 19 | Material andlabour for brick work with sub class ‘B’ bricks, straight or curved on plan exceeding 6 metre mean radius built in cement mortar 1:6, complete all as specified and directed. |
| 20 | M&L for rendering 15 mm thick on fair faces of brick/concrete surfaces cement plaster in CM (1:4), finished even and smooth without using extra cement and with WPC as per manufacturer\"s instruction, including taking down of of existing old plaster complete all as specfified and directed. Note:- WPC shall be measured and paid seperately. |
| 21 | M&L for 15mm thick rendering in CM 1:6 on fair faces of brick/concrete surfaces finished even and smooth w/o using extra cement including Taking down cement plaster on brick or stone walls complete all as specfified and directed. |
| 22 | M&L for preparation of newly plastered or unplastered surfaces in walls and applying 1 coat of wall care white putty 2mm thick and applying 2 coats of oil bound distemper including a coat of compatible wall priming paint complete all as specified and as directed. |
| 23 | M&L for preparation of newly plastered or unplastered surfaces in walls soffits, facia, chajjas and applying two coat of exterior weather proof water based emulsion over a coat of compatible primer complete all as specified and directed. |
| 24 | Supply only integral water proofing compoundcomplete all as specified and directed. |
| 25 | M&L for 25mm thick PCC 1:2:4 type B-0 using 12.5mm graded stone aggregate, including finishing of concrete topping even and rough complete all as specified and directed |
| 26 | M&L for non-skid coloured ceramic tiles 7 to 8mm thick (area of each tiles exc 0.11sqm but not exc 0.18 sqm) in floors and skirting set and jointed in neat cement slurry over and inluding screed bed or bedding layer 15mm thick in CM (1:6) and pointed in white or coloured cement to match with shade of tiles including dismantling of old tiling fixed in any mortar complete all as specified and directed. |
| 27 | M&L for light shade vitrified ceramic tiles (of approved shade and design)area of each tiles not exc 0.36sqm, as in floors and skirtng, etc. set and jointed in neat cement slurry and pointed with white cement over and including 15mm thick screed bed or bedding layer in CM (1:6) including dismantling of old tiling fixed in any mortar complete all as specified and as directed. |
| 28 | M&L for light shade vitrified ceramic tiles (of approved shade and design)area of each tiles exc 0.36sqm but not exceeding 0.42sqm as in floors and skirtng, etc. set and jointed in neat cement slurry and pointed with white cement over and including 15mm thick screed bed in CM (1:6) including dismantling of old tiling fixed in any mortar complete all as specified and as directed. |
| 29 | M&L for light shade vitrified ceramic tiles (of approved shade and design)area of each tiles exc 0.42sqm but not exceeding 1.00sqm as in floors and skirtng, etc. set and jointed in neat cement slurry and pointed with white cement over and including 15mm thick screed bed in CM (1:6) including dismantling of old tiling fixed in any mortar complete all as specified and as directed. |
| 30 | S&F 75mm dia PVC (SWR) pipe and single socketed in any length with rubber ring joint laid in trenches or in floor or fixed to walls incl taking down existing damaged pipe with all fittings complete all as specified and directed. |
| 31 | S&F in repair 110mm dia PVC (SWR) pipe and single socketed in any length with rubber ring joint laid in trenches or floors or fixed to walls incl taking down existing damaged pipe with all fittings complete all as specified and directed. |
| 32 | S&F 75mm bore PVC (SWR) junction (single ‘T’) equal or unequal with access door complete all as specified and directed. |
| 33 | S&F 110mm bore PVC (SWR) junction (single ‘T’) equal or unequal with access door complete all as specified and directed. |
| 34 | S&F 75mm bore PVC (SWR) bend in any radius complete all as specified and directed. |
| 35 | S&F 110mm bore PVC (SWR) bend in any radius complete all as specified and directed. |
| 36 | M&L for prepration of old decorated surface of walls and applyingone coat ofcoloured cement base paint complete all as specified & directed. |
| 37 | M&L for preparation of old decorated plastered or unplastered surfaces and applying two coat of white wash on ceiling complete all as specified and directed. |
| 38 | M&L for preparing of old distempered surface of walls and applying one coat of oil bound distemper complete all asspecified and directed. |
| 39 | M&L for complete removal of existing treatment of ceiling and applying two coat of oil bound distemper over a coat of white putty 2mm thick complete all as specified and directed. |
| 40 | M&L for complete removal of existing treatment on walls and applying 1 coat of wall care white putty and applying two coats of oil bound distemper including a coat of compatible wall priming paint complete all as specified and as directed. |
| 41 | M&L for preparation of old painted surfaces of wood and wood based material of any description over 10cm width or girth and applying one coat of synthetic enamel paintcomplete all as specified and directed. |
| 42 | M&L for preparation of old painted steel surfaces of any description over 10cm width or girth and applying one coat of synthetic enamel paint (approved tint) complete all as specified and directed. |
| 43 | M&L for preparation of old plastered or unplastered surfaces in walls soffits, facia, chajjas and applying one coat of exterior weather proof water based emulsion complete all as specified and directed. |
| 44 | M&L for complete removal of existing treatment using mechanical wall sander ( having mechanical vaccum mechanism) with RPM not less than 1500, sanding pad of 80 grit of dia 7\"/ 9\"on walls (external surface) including brooming to remove dust particles and applying one coat of exterior wall care putty 2mm thick complete all as specified and as directed. |
| 45 | M&L for preparation of old plastered or unplastered surfaces in walls soffits, facia, chajjas and applying two coats of exterior weather proof water based emulsion over one coat of compatible primer complete all as specified and directed. |
| 46 | M&L for writing letters or figures (Block. Roman, Italic or Indian) n exc. 30 cm high all as specified and directed. |
| 47 | Deduct Schedule of credit (calculation will be done off line) Rs. 20100.00 |