Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | Dismantling floor hearth or wall tiling including cement mortar bedding but not backing and removing serviceable tiles to store and rubbish off the premises complete all as specified and directed by Engineer-in-Charge. |
| 2 | Demolition of cement concrete (unreinforced) in ground floors and pavings n exc 15 cm thickness (below or above ground level)complete all as specified and directed by Engineer-in-Charge. |
| 3 | M&L25mm thick Plain Cement Concrete typeB-0,1:2:4 using 12.5mm graded stone aggregates as in sub base complete all as specified and directed by Engineer-in-Charge. |
| 4 | Taking down cement plaster on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water for skirting and dado, etc complete all as specified and directed by Engineer-in-Charge. |
| 5 | M&L Rendering 10 mm thick on brick/ concrete surfaces with cement mortar 1:4 as backing coat complete all as specified and directed by Engineer-in-Charge. |
| 6 | M&L Joint free Non skid Ceramic tiles 7 to 8 mm thick area of each tile exceeding 0.18 sqm but not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over a coat of Screed bedor bedding layer of mortar 15mm thick for laying floor finish in CM 1:4 complete all as specified and directed by Engineer-in-Charge. |
| 7 | M&L for Joint free Glazed ceramic tiles in vertical surface 350x 250x 7 mm/ 450X 350X 7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to matchin vertical surface complete all as specified and directed by Engineer-in-Charge. |
| 8 | M&L PVC corner beading for wall tilling complete all as specified and directed by Engineer-in-Charge. |
| 9 | M&L Machine cut kota stone slab flooring 20 -25 mm thick over cement screed based laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polish complete including 20 mm screed bed layed with CM 1 :4 etc complete all as specified and directed by Engineer-in-Charge. |
| 10 | Demolition of Reinforced cement concrete in Roofs, floors (other than ground floors), beams, staircases, landing, chajjas, RCC Jallies and similar suspended work (reinforcement cut as required to facilitate demolition)and removing debris as directed by engineer-in-Charge |
| 11 | M&L Reinforced cement concrete (nominal mix) Type B1 1:2:4 (20 mm gradedaggregate) in Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like as directed by engineer-in-Charge.Note : Reinforcement shall be measured and paid separately. |
| 12 | Formwork to chullah hoods, chajjas, troughs and similar items including edges Rough finished surface of concrete flat complete all as specified and directed by Engineer-in-Charge. |
| 13 | Formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floor and roofs n exc 20 cm wide and sides of RCC/ PCC bands in walls, horizontal or sloping and similar work exc 5cm but not exc. 10cm wide. Rough finished surfaces of concrete complete all as specified and directed by Engineer-in-Charge. |
| 14 | Demolition of laid stone slabs and tiles of any description or thickness in floor removing the debris complete all as specified and directed by Engineer-in-Charge. |
| 15 | M&L 18 to 20mm thick granite slab (of any type) machine cut bedded jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including cutting, grinding & Polishing of type white marble including making holes for provision of gas pipe for LPG cylinder complete all as specified and directed by Engineer-in-Charge. |
| 16 | Rounding to edges of stone slabs one edge, such as in steps, cooking platform and other similar situations complete all as specified and directed by Engineer-in-Charge. |
| 17 | S&F TMT steel bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips as directed by engineer-in-Charge |
| 18 | Mild steel TMT bars 8mm dia cut to length bent to shape required including cranking bending hooking ends and binding with MS wire (annealed) not less than 0.9mm dia complete all as specified and directed by Engineer-in-Charge. |
| 19 | Demolition of brick work built in cement mortar including all quions,arches, pillars, etc complete all as specified and directed by Engineer-in-Charge. |
| 20 | M&Lold sized Brickwork with fly ash bricks, straight or curved on plan exc 6m mean radius, built in CM 1:6 as in kerb stone and the like etc complete all as specified and directed by Engineer-in-Charge. |
| 21 | M&L old sized half brickwork with fly ash bricks straight or curved on plan exc 6 M mean radius built in CM 1:4 complete all as specified and directed by Engineer-in-Charge. |
| 22 | M&L rendering 10 mm thickon fly as brick walls with CM 1:6 finished even & smooth without using extra cement complete all as specified and directed by Engineer-in-Charge. |
| 23 | Removal of debris obtained from demolition/dismantling upto any distance to outside MD landupto 1.5 km complete all as specified and directed by Engineer-in-Charge. |
| 24 | M&L for 75mm thick Plain cement concrete C-2 type 1:3:6 nominal mix (40mm graded aggregate)as in plinth protection laid in panels complete all as specified and directed by Engineer-in-Charge. |
| 25 | Taking down of steel tubing and connections complete on walls floors etc for 15mm bore of pipe complete all as specified and directed by Engineer-in-Charge. |
| 26 | All as per item No. 25 above but bore of pipe in 20mm dia complete all as specified and directed by Engineer-in-Charge. |
| 27 | All as per item No. 25 above but bore of pipe in 25mm dia complete all as specified and directed by Engineer-in-Charge. |
| 28 | Cutting chases on brick walls, pinning in, making good to facings where required and pointing in CM 1:3 for concealed water tubing cutting not exc 10cm girth complete all as specified and directed by Engineer-in-Charge. |
| 29 | S&F 16 mm CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified and directed by Engineer-in-Charge. |
| 30 | S&F 20 mm CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified and directed by Engineer-in-Charge. |
| 31 | All as per Item No.30 above but outer diameter of the pipe is 25 mm complete all as specified and directed by Engineer-in-Charge. |
| 32 | All as per Item No.30 abovebut outer diameter of the pipe is 50 mm complete all as specified and directed by Engineer-in-Charge. |
| 33 | Refixing of old steel tubing and connectionsin new or old positions (walls ceiling floors etc) bore of pipe 15mm complete all as specified and directed by Engineer-in-Charge. |
| 34 | Refixing of old steel tubing and connectionsin new or old positions (walls ceiling floors etc) bore of pipe 20mm complete all as specified and directed by Engineer-in-Charge. |
| 35 | Refixing of old steel tubing and connectionsin new or old positions (walls ceiling floors etc) bore of pipe 25mm complete all as specified and directed by Engineer-in-Charge. |
| 36 | S&F in repair Vitreous china squatting pan of Orissa pattern size 580 x 440 mm white with P or S trap and integral foot rests (excluding flushing cistern and flush pipe) including trap set inincluding provision of lime/cement concrete bedding complete all as specified and directed by Engineer-in-Charge. |
| 37 | Supply and fixing only in repair PVC valveless, syphonic action type, flushing cistern of 10 litre capacity, low level, white, with inlet, ball valve, float and handle including brackets and flush pipe complete all as specified and directed by Engineer-in-Charge. |
| 38 | S&F in repair viterous china WHB flat back of size 550x400mm incl GI Brackets, CP brass waste coupling with check nut and washers of suitable and waste pipe to be complete all as specified and directed by Engineer-in-Charge. |
| 39 | Supply only 15 mm bore brass Chromium plated Fancy type Pillar tapsfor WHB with capstan heads, screwed down high pressure ,with or without lettered \"Hot or Cold \" with long screwed shanks and fly nuts, screwed for iron pipe complete all as specified and directed by Engineer-in-Charge. |
| 40 | S&F in repairs Swivel shower of PTMT any colour with arm for fixing with 15mm pipe (min weight 40 gms) complete all as specified and directed by Engineer-in-Charge. |
| 41 | S/F in repairs 125mm size brass chromium plated shower rose with swivel jointsincluding fixing to steel/PVC pipes or unions complete all as specified and directed by Engineer-in-Charge. |
| 42 | S&F in repairs vitreous China pedestal patternwhite,(excluding flushing cistern and flush pipe) including connection to trap, and to flushing pipe, anti-syphonage pipe, etc. complete all as specified and directed by Engineer-in-Charge. |
| 43 | S&F in repairs vitreous china bowl urinal flat back, size of 465 x 355 x 265 mm white (minimum), with grating and union for discharge pipe (excluding flushing cistern, flush pipe and waste pipe) complete all as specified and directed by Engineer-in-Charge. |
| 44 | S&F in repairs Urinal spreader of PTMT any colour for fixing with 15 mm dia pipe. (Minimum weight 60gms) complete all as specified and directed by Engineer-in-Charge. |
| 45 | S&F 75mm dia UPVC (SWR) floor trap with grating including jointing with solvent cement complete all as specified and directed by Engineer-in-Charge. |
| 46 | S&F in repairs grating doom 125 mm dia with or without waste hole of PTMT (minimum weight 40 gms) and fixing with grey or white cement complete all as specified and directed by Engineer-in-Charge. |
| 47 | S&F in repairs flush pipe of polyethylene of low or high density or PVC 32 mm dia, for wash hand basin / urinal complete all as specified and directed by Engineer-in-Charge. |
| 48 | S&F in repair 15 mm bore, Cast Copper alloy Chromium plated angle Stop Valve with flange, Screwed down , High pressure with fancy type screwed both ends of iron pipe fancy type, chromium plated with long shank and cup complete all as specified and directed by Engineer-in-Charge. |
| 49 | S&F in repair Stop/angle valves 15 mm bore fancy type, CP with long shank & cup (concelaed type), cast copper alloy screwed down high presure, with crutch of butterfly handle, screwed both ends for iron pipe or for unions complete all as specified and directed by Engineer-in-Charge. |
| 50 | S&F Stop valves for25mm dia, cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed complete all as specified and directed by Engineer-in-Charge. |
| 51 | S&F in repair 15 mm bore brass Chromium plated fancy type bib Taps long shank with flange, crutch or butterfly handle, screwed down , screwed for iron pipe complete all as specified and directed by Engineer-in-Charge. |
| 52 | S&F CP brass Bib tap Swivel type, sink cock swinging spout with flange complete all as specified and directed by Engineer-in-Charge. |
| 53 | S&F Towel Ring of PTMT fixed with and including Chromium plated brass screws and wooden/plastic cleats (Minimum weight 90gms) complete all as specified and directed by Engineer-in-Charge. |
| 54 | S&F Brass chromium plated Tubular towel rail, 20mm dia, D type, 60cm long between flanges complete all as specified and directed by Engineer-in-Charge. |
| 55 | S&F15mm dia PVC Connection 450 mm long with PTMT nuts complete all as specified and directed by Engineer-in-Charge. |
| 56 | S/F Health faucet (ABS Body) mild steel chromium plated suitable for 15 mm dia pipe with 1.25 metre long flexible tube and ABS wall hook including making connections and fixed in position complete all as specified and directed by Engineer-in-Charge. |
| 57 | S&F in repair Brass chromium plated bottle traps for wash basins with inlet and outlet screwed for pipe or connections including necessary packing, union and cap and fixed.Bore of Trap 32mm complete all as specified and directed by Engineer-in-Charge. |
| 58 | S&F in repair Rotational moulded Triple layer polyethylene water storage tank ISI marked (cylindrical Vertical with closed top) hoisted and fixed in position all as specified 2000 litre Capacity and dismantling old unserviceable one. |
| 59 | S&F in repairs 25mm bore Ball brass valves,high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule and fixed complete all as specified and directed by Engineer-in-Charge. |
| 60 | S&F in repair sinks with drainage board made of stainless steel 1mm thick kitchen or laboratory with plugs, washers and wastes; including bedding in cement mortar to dwarf wall or including fixing cantilever brackets and connecting union to pipe and waste pipe overall size 915mm x 460mm bowl size 410mm x 330mm x 160mm complete all as specified and directed by Engineer-in-Charge. |
| 61 | S&F in repair600x450 bevelled edged looking mirror 6mm thick with Design wooden frame work fitted with 6mm thick commerical ply or AC sheet backing to mirror fixed complete all as specified and directed by Engineer-in-Charge. |
| 62 | S&F for angular two way stop cock 15 mm bore chromium platedwith crutch or butterfly handle, fancy type with long shank screwed down both ends for pipes or for union fixed complete all as specified and directed by Engineer-in-Charge. |
| 63 | S&F in repairs PVC (SWR) gully trap 125/110 mm, setting and jointing with solvent cement complete all as specified and directed by Engineer-in-Charge. |
| 64 | S&F in repairs 25mm gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and directed by Engineer-in-Charge. |
| 65 | Taking down rain water pipes, waste/soil pipes (any size or pattern), including all fittings, heads, shoes, bends, swan necks, etc including cleaning or refixingor removal to store complete all as specified and directed by Engineer-in-Charge. |
| 66 | S&F 75mm dia PVC (SWR) pipes single socketed in any length with rubber ring joint laid in trenches or in floors complete all as specified and directed by Engineer-in-Charge. |
| 67 | All as per item No 66 above but 110 mm bore complete all as specified and directed by Engineer-in-Charge. |
| 68 | S&F 75mm dia PVC (SWR) pipes single socketed in any length with rubber ring joint fixed complete to walls complete all as specified and directed by Engineer-in-Charge. |
| 69 | S&F 110mm dia PVC (SWR) Pipe single socketed in any length with rubber ring joints fixed complete to walls complete all as specified and directed by Engineer-in-Charge. |
| 70 | S&F 75mm dia PVC (SWR) bend without access door complete all as specified and directed by Engineer-in-Charge. |
| 71 | S&F 110mm dia PVC (SWR) bend without access door complete all as specified and directed by Engineer-in-Charge. |
| 72 | S&F 75mm dia PVC (SWR) bend with access door complete all as specified and directed by Engineer-in-Charge. |
| 73 | S&F 110mm dia PVC (SWR) bend with access door complete all as specified and directed by Engineer-in-Charge. |
| 74 | S&F 75mm dia Branch piece single (single Y) equal or unequal with access door complete all as specified and directed by Engineer-in-Charge. |
| 75 | S&F 110mm dia Branch piece single (single Y) equal or unequal with access door complete all as specified and directed by Engineer-in-Charge. |
| 76 | S&F 75mm dia branch piece double (double Y ) equal or unequal provided with acess door complete all as specified and directed by Engineer-in-Charge. |
| 77 | S&F 110mm dia branch piece double (double Y ) equal or unequal provided with access door |
| 78 | S&F 75mm dia PVC (SWR) junction single (Single T ) equal or unequal with access door complete all as specified and directed by Engineer-in-Charge. |
| 79 | S&F 110 mm dia PVC (SWR) junction single (Single T ) equal or unequal with access door complete all as specified and directed by Engineer-in-Charge. |
| 80 | S&F 110mm dia PVC (SWR) junction single (Double T ) equal or unequal with access door |
| 81 | Taking down chowkats/Frames of area n.exc 1.5 Sqm with shutter (without taking off shutters from the frame) each complete all as specified and directed by Engineer-in-Charge. |
| 82 | Taking down chowkats/Frames of area exc 1.5 Sqm and n.exc 4.0 Sqm with shutter (without taking off shutters from the frame) each complete all as specified and directed by Engineer-in-Charge. |
| 83 | Taking down Shutters of any description exc 1 sq. m and n exc 2 sq. m each complete all as specified and directed by Engineer-in-Charge. |
| 84 | S/F fixing aluminium powder coated (Minimum thickness of powder coating 50 micron) frame for windows/ Doors/Ventilators/Partitions with one or more tracks including joining cleats/ channel for fixing glass/ mesh complete all as specified and directed by Engineer-in-Charge. |
| 85 | S F Aluminium powder coated (minimum thickness of powder coating 50 micron) side hung/sliding window/ ventilators shutters (I max) of aluminium section for frame work of shutters not less than 0.55 Kg/RM including necessary jointing cleats glazing clips, rubber packing anodised aluminium snap beads, screw, roller inter locking handles including 75 mm SS Hinges-02 Nos, 125 mm handles - 01 No, 125 mm long tower bolts - 02 Nos each shutter etc complete all as specified and directed by Engineer-in-Charge.Note : Glass panes and wire mesh shall be measured and paid separately. |
| 86 | S&F Stainless steel wire mesh of nominal dia of wire 0.36mm and average width of aperture 1.40mm & fixed with stainless steel wire staples including wooden fillets/beadings, screws etc complete all as specified and directed by Engineer-in-Charge. |
| 87 | S&F in repair sheet glass 4mm thick plain ordinary quality and glazing with oil putty wooden beads as directed in squares n exc 0.50 sqm in each pne as in repairs complete all as specified and directed by Engineer-in-Charge. |
| 88 | S&F aluminium powder coated grills (pattern DG-104) weight of 2.00 to 3.20 Kg/Sqm for windows, ventilators, etc including jointing, cleats etc and fixed with medium screws into walls / frame work etc complete all as specified and directed by Engineer-in-Charge. |
| 89 | S&F 4mm thick Figured glass, pin head type and glazing with oil putty in squares n exc 0.5 sq. m in each pane for ventilator shutters complete all as specified and directed by Engineer-in-Charge. |
| 90 | S&F 2nd class Hard wood plain, solid, straight chowkats and frames wrought, framed rebated on the solid, rounded or chamfered, put together with glue pinned at joint complete all as specified and directed by Engineer-in-Charge. |
| 91 | S&F second class hardwood rail and style Plain framed, panelled shutter thickness of shutters 35mm with lock rail and panel of 9 mm B.W.P. commercial ply or 12 mm veneered particle board with commercial veneering on both faces. The size of rail and stile as per IS : 1003 (Part I), kiln seasoned and chemically pressure treated complete all as specified and directed by Engineer-in-Charge. |
| 92 | S&F Flush shutters 30 mm thick, solid core construction, with block board core and plywood face panels, commercial type on both sides complete all as specified and directed by Engineer-in-Charge. |
| 93 | S&F 2nd class Hard wood glazed/skeleton shutters 35mm thick open rebated prepared to receive glass, gauze divided in squares with plain, chamfered or rounded, mitred and with out sash bars ,chamfered or rounded, mitred and rebated beads for securing glass gauze etc complete all as specified and directed by Engineer-in-Charge. |
| 94 | S&FAluminium anodised barrel tower bolt of extruded section of size 150mm complete all as specified and directed by Engineer-in-Charge. |
| 95 | All as per item No 94 above but fixed in repair complete all as specified and directed by Engineer-in-Charge. |
| 96 | S&F Aluminium alloy, anodised sliding door bolt, with hasp, staple (bolt type) and fixing clips of sheets, cast or extruded section and fixing bolts and sliding bolt of extruded section or cast alluminium alloy of size 200 mm complete all as specified and directed by Engineer-in-Charge. |
| 97 | S&F in repair Aluminium alloy, anodised sliding door bolt, with hasp, staple (bolt type) and fixing clips of sheets, cast or extruded section and fixing bolts and sliding bolt of extruded section or cast alluminium alloy of size 300 mm complete all as specified and directed by Engineer-in-Charge. |
| 98 | S&F Butt hinges, cast brass, with mild steel hinge pin, 100mm bright polished and fixed type B-11 complete all as specified and directed by Engineer-in-Charge. |
| 99 | S&F Extruded Aluminium alloy handle fabricated type, anodised of size 150mm complete all as specified and directed by Engineer-in-Charge. |
| 100 | S&F in repair Floor door stopper of aluminium alloy body and tongue anodised with hard drawn steel spring 150mm long complete all as specified and directed by Engineer-in-Charge. |
| 101 | S&FFloor door stopper of aluminium alloy body and tongue anodised with hard drawn steel spring 150mm long complete all as specified and directed by Engineer-in-Charge. |
| 102 | S& F 300mm size mild steel ordinary rat & tail rod pattern spring (Helical) including roller & roller plate complete all as specified and directed by Engineer-in-Charge. |
| 103 | All as per item No 102above but fixed in repair complete all as specified and directed by Engineer-in-Charge. |
| 104 | M&L for preparing new wooden surfaces of any description over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and directed by Engineer-in-Charge. |
| 105 | Cutting holes in to brick wall built in cement mortar exc half brick & n.exc full brick and making good in cement mortar 1:3 or cement concrete 1:2:4 Type B-1 as required complete all as specified and directed by Engineer-in-Charge. |
| 106 | M&L for small articles such as hold fasts etc. of Flat Iron 25 x 3mm, Grade confirming to Fe-290 Gde E-165 complete all as specified and directed by Engineer-in-Charge. |
| 107 | M&L for preparing for creosote small articles such as hold fasts, end of posts etc. of area n.exc 0.1Sqm and treated with tar or coal tar black paint complete all as specified and directed by Engineer-in-Charge. |
| 108 | S&F rubber beading/snake guard of minimum 4mmm thickness and requisite width to be fixed at bottom of the door complete all as specified and directed by Engineer-in-Charge. |
| 109 | S&F in repairs door closer, aluminium (extruded section body) hydraulically regulated, designation No. 3, universal type, suitable for door shutters of 851 to 1000 mm in width and weight between 61 to 80kg complete all as specified and directed by Engineer-in-Charge. |
| 110 | Resecuring or easing & adjusting without taking down shutters of any description exc 1 Sq.m and n.exc 2 Sqm each complete all as specified and directed by Engineer-in-Charge. |
| 111 | Running welding in repairs Thickness of metal to be welded n.exc 6 mm complete all as specified and directed by Engineer-in-Charge. |
| 112 | Welding in repairs exc 2.5cm but n exc 5cm in lengthfor hinges in cold pressed steel door frame etc complete all as specified and directed by Engineer-in-Charge. |
| 113 | S & F for Joist, channel, angle, or tee sections,fixed indpendently, without connecting plates, etc. (cut to ordinary lengths i.e. within 20mm of the length indicated) complete all as specified and directed by Engineer-in-Charge. |
| 114 | M&L preparation of new decorated steel surfaces exc. 10cm width or girth and applying two coats of synthetic enamel paintover coat of primer complete all as specified and directed by Engineer-in-Charge. |
| 115 | S&F ball catches with 8mm dia steel ball and brass body and striking plate including letting in and fixed complete all as specified and directed by Engineer-in-Charge. |
| 116 | S & F in repairs for 75 mm brass Locks 2 levers, drawer,grade I, size 50mm complete all as specified and directed by Engineer-in-Charge. |
| 117 | S&F in repair for Harrison rails, mild steel, chromium plated with fixing brackets,stops, rollers including all fixing works etc complete all as specified and directed by Engineer-in-Charge. |
| 118 | S&F Factory made solid PVC Moulded flush door shutter 28 to 30mm thick (style) with 2,4 or 6 raised panel design with 2mm thick moulded PVC sheet on the front face & 2mm thick plain colour prelaminated PVC sheet on back face supplying & fixing in frame at site as per specification & drawing complete all as specified and directed by Engineer-in-Charge. |
| 119 | M&L for solid PVC door frame of size 50mm x 47mm made out of 5mm plain colourPVC sheet reinforced with MS Square tube complete all as specified and directed by Engineer-in-Charge. |
| 120 | S&F factory made pre laminated 18mm thick lead free 100% solid WPC (wood polymer composite) sheet one side prelam sheet and other side wood nature colour for shutter having high natural fiber content 25 to 30% wood colour sheet with density not less than 600kg/Cum and WPC to be laminated with PVC foil of min 14 micronthick of approved design incl 100% termite/water proof,fire retardant, Eco friendly an finish at all edges at level of making edges lipping using biding tape etc as in kitchen cupboard, cabinet etc complete as per direction of Engineer In Charge and manufacturer\"s specification complete all as specified and directed by Engineer-in-Charge. |
| 121 | S&Fin repair continuous piano hinges mild steel bright finish or electrogavanised with flaps 30mm (when open) wide complete all as specified and directed by Engineer-in-Charge. |
| 122 | S&F in repair40mm dia, cupboard knobs fixed with nut, screw and washer of mild steel, bright finished complete all as specified and directed by Engineer-in-Charge. |
| 123 | S&F magnetic catcher as approved by GE, fixed with nut and bolt complete all as specified and directed by Engineer-in-Charge. |
| 124 | M&L for Rendering 15 mm thick in CM 1:4 in two coats (1st coat 10mm thick,finishing coat 5 mm thick with WPC @3% finished even and faircomplete all as specified and directed by Engineer-in-Charge. |
| 125 | M&L Rendering 5mm thick in CM 1:3 on as in ceiling of fair faces of brick work or concrete surfaces finished even and smooth without using extra cement complete all as specified and as directed |
| 126 | M&L rendering 10 mm thickon brick walls with CM 1:6 finished even & smooth without using extra cement complete all as specified and directed by Engineer-in-Charge. |
| 127 | M&L for preparation of New plastered surfaces of wall and applying two coats of Oil bound distemper over a coat of wall care putty2 mm thick over a coat of primer complete all as specified and directed by the engineer-In-Charge. |
| 128 | M&L for preparation of New plastered ceiling surfaces and applying three coat of white wash on ceiling complete all as specified and directed by the engineer-In-Charge. |
| 129 | M&L preparation of new surfaces of external walls and applying one coat of primer and two coats of weather proof exterior emulsion paint (weather coat Apex, 100% exterior grade) complete all as specified and directed by Engineer-in-Charge. |
| 130 | M& L Post constructional Anti termite treatment, along external wall below concrete or masonary apron using chemical emulsion @ 2.25 litres per linear metre incl drilling and plugging holes etc in apron complete all as specified and directed by Engineer-in-Charge.Note :The subject ATT work shall need to be carried out through authorised applicator as per concerned department and certificate in this regard will be produced accordingly. |
| 131 | M & L Post constructional Anti termite treatment of soil under existing floors using emulsion @ one litre per hole, 300mm apart including drilling and plugging 12mm dia holes with cement mortar 1:2 (1 cement : 2 coarse sand) to match the existing floors complete all as specified and directed by Engineer-in-Charge.Note :The subject ATT work shall need to be carried out through authorised applicator as per concerned department and certificate in this regard will be produced accordingly. |
| 132 | M & L Post constructional Anti termite treatment at points of contact of wood work by chemical emulsion (in oil or kerosene based solution) @ 0.5 litre / hole by drilling 6mm dia holes at a downward angle of 45 degree at 150mm centre to centre and sealing the same complete all as specified and directed by Engineer-in-Charge.Note :The subject ATT work shall need to be carried out through authorised applicator as per concerned department and certificate in this regard will be produced accordingly. |
| 133 | M&L Providing 50mm Precast cement concrete louvers and jallies in repairs, thick (measured solid), including all mouldings. Set in Cement Mortar 1:4, Type B0, 1:2:4, using 12.50mm graded aggregate complete all as specified and directed by Engineer-in-Charge. |
| 134 | M&L for Framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framedbalusters; walk ways; railings; framework of water tanksand similar work conforming to including joining welding and connecting each other to form a cage for water tanksFe.290.Gde-E-165 complete all as specified and directed by Engineer-in-Charge. |
| 135 | M&L for preparing Old Steel surfaces of any description and applying one coat of synthetic enamel paint complete all as specified and directed by Engineer-in-Charge. |
| 136 | M&L Preparation of old treated wooden Surfaces of any description, over 10cm in width or girth and applying one finishing coat of varnish complete all as specified and directed by Engineer-in-Charge. |
| 137 | M&L preparation of old decorated surfaces of wood work exc. 10cm width or girth and applying one coat of synthetic enamel paint complete all as specified and directed by Engineer-in-Charge. |
| 138 | M&L preparation of old decorated surfaces of ceiling and applying one coat of white wash evenly complete all as specified and directed by Engineer-in-Charge. |
| 139 | M&L for complete removal of existing treatment of wall, including Washing, rubbing down and stopping of distempered and painted surfaces of pilasters, including cornices and applying two coats of Oil Bound Distemper over a coat of alkali resistance primer and wall care putty including preparation of surfaces complete all as specified and directed by Engineer-in-Charge. |
| 140 | Material & Labour for applying one coat of alkali resistant priming paint and over of primer applyig two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces. etc as per existing or as approved tint/colour complete all as specified and directed by Engineer-in-Charge. |
| 141 | S&F three tier washing system made up of Statinless steel 304 (Three sink unit) of size 72\"x24\"x34\" and each bowl of size 18x18x12\" (Square type), top sheet SWG thic sheet 4 legs, 1.5\" square pipe with bottom adjustable nylon brush, cross pipe 1\". This item installationincludes necessary plumbing fittings complete all as specified and directed by Engineer-in-Charge. |
| 142 | Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out hard/dense soil complete all as specified and directed by Engineer-in-Charge. |
| 143 | M&L Plain cement concrete, type D2 (1:4:8, 40mm graded stone aggregate) asin foundations,filling and mass concrete including necessary formwork complete all as specified and directed by Engineer-in-Charge. |
| 144 | M&L Plain cement concrete type B1, 1:2:4 (20mm graded stone aggregate) as in coping, benching and the like including weathering, slightly rounded or chamfered angles and throating etc complete all as specified and directed by Engineer-in-Charge. |
| 145 | M&L Returning, filling in hard dense soil, including spreading, levelling, watering and well ramming in layers not exc 25 cm complete all as specified and directed by Engineer-in-Charge. |
| 146 | M&L Removing excavated material of hard dense soil n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and directed by Engineer-in-Charge. |
| 147 | M&L for Precast cover slab 1:2:4, type B1 (using 20mm graded aggregate) inlandings, cover slabs (for manholes etc.,) chullah hoods, chajjas, water troughs, mangers, shelves and similar articles with plain faces set in CM 1:4, for manholes complete all as specified and as directed etc complete all as specified and directed by Engineer-in-Charge.Note : Reinforcement shall be measured and paid separately. |
| 148 | S&F TMT steel bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed by Engineer-in-Charge. |
| 149 | M&L Plain cement concrete bed to drain pipes including packing under, and haunching against the sides of pipes after they are laid and tested;in cement concrete 1:3:6, Type C2 (using 40mm graded stone aggregate) for 110mm dia pipes complete all as specified and directed by Engineer-in-Charge. |
| 150 | M&L Cutting into existing manholes for connecting new drains, making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in plain cement concrete 1:2:4 type B1 smooth finished, and reforming benchingfor 150mm dia as required complete all as specified and directed by Engineer-in-Charge. |
| 151 | Material and labour for point wiring concealed type for One light point controlled by one switch with 1.5 sqmm PVC FRLS insulated,un-sheathed 1100 volts grade copper conductor single core multi stranded drawn through with and including non metallic rigidPVC rigid conduit not less than 20 mm dia with its accessories concealed on walls, suface on ceiling etc., with suitable clamps/ shaddles, including provision ofsuitable 1.6 mm thick MS pressed steel terminal boxes concealed suitable to modular sockets/switches including modular cover frame and plate in wall for housing of modular switiches, sockets, fan regulators etc., including one run of 1.50 sqmm PVC insulated copper conductor for continuous earth wire and connected to common earth dolly complete all as specified and directed by Engineer-in-Charge. |
| 152 | All as per item No.151 above but for One light point controlled by Two switch complete all as specified and directed by Engineer-in-Charge. |
| 153 | All as per item No.151 above but for One fan point controlled by one switch complete all as specified and directed by Engineer-in-Charge. |
| 154 | All as per item No.151 above but for One socket point on Independent board complete all as specified and directed by Engineer-in-Charge. |
| 155 | All as per item No.151 above but for One socket point on same board with other switches complete all as specified and directed by Engineer-in-Charge. |
| 156 | All as per item No.151 above but with 2.5 sqmm for power point 15 amps complete all as specified and directed by Engineer-in-Charge. |
| 157 | All as per item No.151 above but with 4.0 sqmm for AC point/ Equipts socket outlet 15 amps complete all as specified and directed by Engineer-in-Charge. |
| 158 | S&F Modular Switch flush type, 6 amps 240 volts single pole one way complete all as specified and directed by Engineer-in-Charge. |
| 159 | S&F Modular switchflush type 6 Amps, Single Pole Two way complete all as specified and directed by Engineer-in-Charge. |
| 160 | S&F Modular Switch flush type, 16 amps 240 volts single pole one way complete all as specified and directed by Engineer-in-Charge. |
| 161 | S&F Ceiling rose surface PVC insulatedthree plates \"JUMBO\" type 240 volts complete all as specified and directed by Engineer-in-Charge. |
| 162 | S&F Modular socket outlet 2/3 pin 6 amps 240 volts flush type, two module complete all as specified and directed by Engineer-in-Charge. |
| 163 | S&F Modular socket out let 6/16 Amp 6pin flush type two module complete all as specified and directed by Engineer-in-Charge. |
| 164 | S&F Modular Fan regulator electronic type with five stepped control suitable for 1200/1400 mm ceiling fan complete all as specified and directed by Engineer-in-Charge. |
| 165 | S&F in replacement of Wall mounted light fitting LED batten, extruded aluminium heat sink provided for efficient heat dissipation & integrated electronic driverwith 22 W LED (4 feet) lampincluding disconnecting, removing,and connecting into electric circuit and testing complete all as specified and directed by Engineer-in-Charge. |
| 166 | Supply and fixing LED luminaire 600 mm x 600 mm, 35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete all as specified and directed by Engineer-in-Charge. |
| 167 | S&F in replacement of Mirror light fitting LED luminares New generation energy savingIP65 Mirror light luminaire with opal diffuserwith 10W LED including disconecting, removing,and connecting into electric circuit and testing complete all as specified and directed by Engineer-in-Charge. |
| 168 | S&F in replacement of security light fitting LED luminares New generation energy saving & environmental friendly long life versatile pressure die-cast aluminium IP65 roadway luminaire with high power LED as light sourcewith 35W LED 5000K lampincluding disconecting, removing,and connecting into electric circuit and testing complete all as specified and directed by Engineer-in-Charge. |
| 169 | S&F GI Bracket bend to shape in cold or hot 40mm bore medium grade and 1.50metre long with suitable MS clamps and nuts bolts etc, to fixing security light fittings to Bldgs complete after taking down the unsv GI bracket complete all as specified and directed by Engineer-in-Charge. |
| 170 | Cutting chases, pinning in making good to facings where required and pointing in cement motor 1:3 to ends or edges of landings steps, chills, sunshades, shelves, lintels etc and cutting chases for concealed conduit wiring etc. and making good cutting exceeding 10cm but not exceeding 20cmgirth complete all as specified and directed by Engineer-in-Charge. |
| 171 | M&L for Sub main wiring two run of 4 sqmm single core PVC insulated unsheathed cablesingle core multistranded FRLS copper conductor 1100 volts grade drawn through suitable size of PVC conduit and conduit accessories concealed on floor/wall/ surface on ceiling with suitable clamps/saddles including one run of 6 sqmm PVC insulated FRLS copper cable for continuous earth conductor connected to common earth dolly complete all as specified and directed by Engineer-in-Charge. |
| 172 | M&L for Sub main wiring two run of 6 sqmm single core PVC insulated unsheathed cablesingle core multistranded FRLS copper conductor 1100 volts grade drawn through suitable size of PVC conduit and conduit accessories concealed on floor/wall/ surface on ceiling with suitable clamps/saddles including one run of 6 sqmm PVC insulated FRLS copper cable for continuous earth conductor connected to common earth dolly complete all as specified and directed by Engineer-in-Charge. |
| 173 | M&L for Sub main wiring four runs of 6 sqmm single core PVC insulated unsheathed cablesingle core multistranded FRLS copper conductor 1100 volts grade drawn through suitable size of PVC conduit and conduit accessories concealed on floor/wall/ surface on ceiling with suitable clamps/saddles including one run of 6 sqmm PVC insulated FRLS copper cable for continuous earth conductor connected to common earth dolly complete all as specified and directed by Engineer-in-Charge. |
| 174 | M&L for Sub main wiring four runs of 10 sqmm single core PVC insulated unsheathed cablesingle core multistranded FRLS copper conductor 1100 volts grade drawn through suitable size of PVC conduit and conduit accessories concealed on floor/wall/ surface on ceiling with suitable clamps/saddles including one run of 10 sqmm PVC insulated FRLS copper cable for continuous earth conductor connected to common earth dolly complete all as specified and directed by Engineer-in-Charge. |
| 175 | S&F Single pole and neutral enclosure with a two pin and earth plug and socket complete one single pole MCB 20/30 Amps, 240V complete concealed on wall and connecting with all connections complete all as specified and directed by Engineer-in-Charge. |
| 176 | Refixing of Single pole and neutral enclosure with a two pin and earth plug and socket complete one single pole MCB 20/30 Amps, 240V complete concealed on wall and connecting with all connections complete all as specified and directed by Engineer-in-Charge. |
| 177 | Supply & fixing of Sheet metal enclosure with distribution board Double Door 230 volts SPN 8 way with suitable Bus bar and provision for MCBs/ isolators fixed on wall and connecting with all connections complete all as specified and directed by Engineer-in-Charge. |
| 178 | Supply & fixing of Sheet metal enclosure with distribution board Double Door 230 volts SPN12 way with suitable Bus bar and provision for MCBs/ isolators fixed on wall and connecting with all connections complete all as specified and directed by Engineer-in-Charge. |
| 179 | Supply & fixing of Vertical type sheet metal enclosure MCB DB TPN 8 ways double door typeincluding 125 Amps MCCB 4 Pole 415 V,16 KA incomer with suitable bus bar surface/concealed on wall and connecting with all connections complete all as specified and directed by Engineer-in-Charge. |
| 180 | Supply & fixing of Vertical type sheet metal enclosure MCB DB TPN 4 ways double door typeincluding 63 Amps MCCB 4 Pole 415 V,16 KA incomer with suitable bus bar surface/concealed on wall and connecting with all connections complete all as specified and directed by Engineer-in-Charge. |
| 181 | S & F MCB 6 to 32/40 amps, breaking capacity 10 KA , SP 240V complete all as specified and directed by Engineer-in-Charge. |
| 182 | S & F MCB \"B\" curve SPN 6-32/40 Amps, breaking capacity 10 KA , 240V complete all as specified and directed by Engineer-in-Charge. |
| 183 | Supply and fixing for Isolator TP 63Amps, 10KA 240volts,50Hz complete all as specified and directed by Engineer-in-Charge. |
| 184 | Supply and fixceiling fans 1200 mm sweep, energy saving BLDC, 230 V AC 50 HZ complete with down rod complete all as specified and directed by Engineer-in-Charge. |
| 185 | Supply and fix exhaust fan, steel body AC single Phase. 230V of size 300m sweep with, blades, and frame and louvers complete all as specified and directed by Engineer-in-Charge. |
| 186 | Material and labour for earthing complete with GI plate electrode 600x600x6mm thick, buried directly in ground (earth pit not less than 2.25m deep below ground level) with top edge of plate not less than 1.5m below ground level connected to earth lead of 4.0 mm GI wire means of bolts, nuts, washers of galvanized all as shown in electrical plate No.3 of SSR Part-I including necessary excavation and earth work.PCC 1:3:6 type C1 chamber, RCC cover in 50mm thick 1:2:4 type B1 with 8mm CTD 140mm centre to centre with suitable handle, watering pipe 20mm dia light grade pipe with funnel, charcoal salt connected to earthing test point all as specified including testing and commissioning on completion complete all as specified and directed by Engineer-in-Charge. |
| 187 | M&L for earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/ pipe or fixed to poles or any other indicated situation for loop earthing etc. as required GI wire 4.0 mm thick for inter connecting of earth electrodes complete all as specified and directed by Engineer-in-Charge. |
| 188 | S&F PVC non metallic rigid conduit not less than 20 mm dia with itsconduit accessories concealed on floor/wall/ surface on ceiling with suitable clamps/saddles rigid non-metallic PVC conduit exclusive of boxes (junction/terminal) but inclusive of all tees, bends,elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc complete all as specified and directed by Engineer-in-Charge. |
| 189 | M&L Ceiling fan hook made out of MS bar 10mm dia bar bend to shape or anchor fastener with hook for shifting/hanging ceiling fans complete all as specified and directed by Engineer-in-Charge. |
| 190 | Refixing of LED/CFL light fittings any type including treplace the necessary connections complete all as specified and directed by Engineer-in-Charge. |
| 191 | Taking down Split ACup to 2.0Ton complete with indoor & out door units and deposit to E/m store for safe custody including electrical connections complete all as specified and directed by Engineer-in-Charge. |
| 192 | M&L for refixing the split AC up to 2.0Ton colecting from E/M store after completed the B/R work including necessary servicing, gas top up & replacement of minor spares if requiredcomplete all as specified and directed by Engineer-in-Charge. |
| 193 | S&F Supply and fix ON LOAD change over switch 415V in sheet metal enclosures 4 pole of capacity 125 Amp complete all as specified and directed by Engineer-in-Charge. |
| 194 | Taking down sub main wiring any description along with PVC conduit/Casing capping/wooden batten/metal conduit and made good the disturbed surface complete all as specified and directed by Engineer-in-Charge. |
| 195 | Taking down unserviceable DB/metal clad boxesany description or size/way incl MCCB/MCBs complete all as specified and directed by Engineer-in-Charge. |
| 196 | Taking down fan, ceiling cable end, dismantling blades and removing fan and blades to store for Servicable one for reuse& Un serviceable.one for BER process complete all as specified and directed by Engineer-in-Charge. |
| 197 | Hanging/Refixing only ceiling fan (MD supply) and connecting up including provision of cable from ceiling rose or connector to fan complete all as specified and directed by Engineer-in-Charge. |
| 198 | Taking down Exhaust fan, ceiling rose, dismantling blades and removing fan and blades to store.for Servicable one for reuse& Un serviceable one for BER process complete all as specified and directed by Engineer-in-Charge. |
| 199 | Refixing only Exhaust fan (MD supply) and connecting up including provision of cable from ceiling rose or connector to fan complete all as specified. |
| 200 | M & L for painting of ceiling fan/exhaust fanany sweep, complete in situ with synthetic enamel paint by spraying including filling cavities with filler, one coat after cleaning all dust etc complete all as specified and directed by Engineer-in-Charge. |
| 201 | Taking down old aluminium point wiring (light, fan, socket or power) complete fittings such as switches,sockets,ceiling rose, pendents, regulators etc complete as ordered and removing retrived materials and making good the disturbed surface of wall, floors, ceiling etc complete all as specified and directed by Engineer-in-Charge. |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
| 5 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail