| Sl. No. | Item Description |
| 1 | Taking down cement plaster of any description incl raking out joints, hacking for scrubbing down with water etc. |
| 2 | M&L 15mm thick cement plaster in cement mortar 1:6 on brick or concrete surface finished even and smooth withoutusing extra cementall as specified |
| 3 | M&L for 15 mm thick rendering in cement mortar 1:4 on fair faces of brick or concrete walls, finished even and fair without using extra cement to match with the existing surfaces including WPC,Complete all as specified and directed. |
| 4 | M&L for prepration of new plaster surfaces of walls and applying two coats of oil bound distemper including a coat of primer on plastered surfaces over a coat of wall putty complete all as specified. |
| 5 | M&L for prepration of new plaster surfaces of walls and applying two coat of plastic emulsion paint over a coat of primer over and a coat of wall putty complete all as specified and directed. |
| 6 | M&L for Complete removal of existing treatment of walls, washing, rubbing down and stopping of distempered and painted surfaces and applying two coat of oil bound distemper over a coat of primer over and a coat of wall putty complete all as specified and directed. |
| 7 | M&L for Complete removal of existing treatment of walls, washing, rubbing down and stopping of distempered and painted surfaces and applying two coat of plastic emulsion paint over a coat of primer over and a coat of wall putty complete all as specified and directed. |
| 8 | M&L for prepration of old wooden surfaces of any description not otherwise described over 10 cm width or grith and applying one coat of synthetic enamel paint complete all as specified and directed. |
| 9 | M&L for prepration of old steel surfaces of any description not otherwise described over 10 cm width or grith and applying one coat of synthetic enamel paint complete all as specified and directed. |
| 10 | M&L for prepration of old surfaces of ceiling including brooming down or steel wire brushing; scraping down smoke soot, moulds, moss and efflorescent and trading oil and greasy spots etc (Plastered or unplastered surfaces) and applying one coat of white (lime) wash complete all as specified and directed. |
| 11 | Demolition of cement concrete of any description and in any position not otherwise specifically provided complete all as specified and directed |
| 12 | M &L for Water proofing treatment to sunken floors of kitchen, toilets, laboratories, bath and WCs etc shall be as under:-(i) Application of Two component acrylic modified cementitious coating(aa)The surfaces to be applied shall be completely dry and free from containments such as dirt, dust, oil, surface treatments and old coatings. Concrete substrates must be mechanically prepared using abrasive blast cleaning or milling to remove cementlaitance, existing coating and achieve a gripping profile that is clean, dry and free from laitance and dry other form of surface contamination. The installation instructions in manufacture\"s published literature should be strictly complied with, including but not limited to the following:-(bb)Chipping out any visible cracks in \"V-Groove\" pattern as applicable. Special attention on this part. Cleaning of cracks & then filling those cracks with SIKA latex SBR 100 putty/Dr Fixit 302 SBR latex/ Perma latex SBR/FOSROC Nitabond SBR latex/Asian paint latex as required. Final cleaning of surface with power grinder, wire brush, hair brush & vacuum pressure if required.(cc)Dampen all surfaces immediately ahed of application of Acrylic modified Cementitious coating of sika Top Seal-107/Brush Bond FOSROC/Dr Fixit/STP/CICO.(dd) Whilst the surface is still damp from saturation (S.S.D), apply one coat of Acrylic modified cementitious coating of SIKA Top Seal-107 /Brush Bond FOSROC/Dr Fixit/STP/CICO of viscosity as per manufacturer\"s instructions. (ee)Apply glass fabric sheet of SIKA Fab 1/FOSROC/Dr Fixit/STP whilst the first coat is wet.(ff) Once touch dry, apply second coat of Acrylic modified cementitious coating of SIKA Top Seal -107 /Brush Bond FOSROC/Dr Fixit/STP/CICO of viscosity as per manufacturer\"s instructions on the entire area.(gg) Second coat shall be applied after 6-8 Hrs of application of previous coat and in the direction right angle to the previous coat.(hh)The waterproofing coating should be taken to a height minimum 300mm above the finished floor level on the vertical surfaces.(jj) It is essential to cure Acrylic modified cementitious coating immediately after application (minimum 6-8hrs drying) for a minimum of 3 to 5 days to ensure full cement hydration and to minimize cracking.\"(kk)A protection plaster 12-15mm thick) in CM 1:3 admixed with appropriate integral water proofing compound has to be applied on the walls. Admixture: SIKA Plastocrete Plus/FOSROC/DR Fixit/STP/CICO conforming to IS 2645.Providing and applying a protection screed of 50mm thick 1:4, cement sand mortar admixed with SIKA Plastocrete over the applied water proofing coating on horizontal surfaces. Admixture: SIKA Plastocrete Plus/FOSROC/DR Fixit/STP/CICO conforming to IS 2645.\"(ll)All the corners and joints should be pretreated with an elastic waterproofing sealing tape with a woven bonding mesh on each surface and an elastic expansions zone in the centre of Make SIKA Seal Tape/FOSROC/Dr Fixit/STP.(mm) The membrane has to be protected in accordance with the manufacturer\"s recommendations until placement of concrete. The membrane to be inspected for damage just prior to concrete placement and make repairs in accordance with manufacturer\"s recommendations.(nn) Waterproofing treatment has to be carried out through applicators authorised by the respective manufacturer\"s and approved by GE.(ii) All the joints of pipes and traps within the sunken portion shall be sealed properly by epoxy sealent.(iii) All CI traps in sunken slab to be enclosed with PCC 1:1.5:3 (Min15cm) all around.(iv) The sunken portion shall be filled with PCC 1:5:10 type E-2 (using 40mm stone aggregate) complete all as specified.(v) Providing drainage spout pipe GI pipe 40mm dia bore light grade upto outside of outer wall ( Approx 450mm to 600 mm long )including cutting to existing wall and making good the disturbed surface complete all as specified and directed.\"(vi) Providing 25mm thick cement concrete 1:2:4 type B-0 using 12.5mm graded stone aggregate as in flooring for laying floor finish all as specified.Note:-Item No 12 (iv) ,(v) &(vi) shall be measured and paid separately.\" |
| 13 | M&L 25 mm thick cement concrete flooring type B-1, 1:2:4 using 20 mm graded stone aggregate finishing cement concrete surface even and smooth without using extra cement. |
| 14 | M&L for cement concrete type E - 2, 1:5:10 (using 40 mm graded stoneaggregate) as in sunken flooring. |
| 15 | M & L for 50mm dia GI pipe,med grade beveled cut at both ends by making hole in walls sunken portion aprox above the RCC slab and ceiling finished the hole with cement plaster 1:2 to match with existing surface complete etc.(Measured for cutting holes shall be paid in concerned sch item) |
| 16 | Dismantaling floor hearth or wall tiling/china moisac including cement mortarbedding (but not backing ) , removing serviceable tiles to store andrubbish off the premises complete all as specified. |
| 17 | S&F Non skid ceramic coloured 7 to 8 mm thick area of each tile exc 0.11 sqm but n.exc 0.18 Sqm in floors etc., set and jointed in neat cement slurry and pointed in coloured cement to match including 15mm thick screed bed 1:6 cm complete all as specified and as directed. |
| 18 | S&F Non skid ceramic coloured 7 to 8 mm thick area of each tile exc 0.18 sqm but n.exc 0.38 Sqm in floors etc., set and jointed in neat cement slurry and pointed in coloured cement to match including 15mm thick screed bed in CM (1:6) ,complete all as specified and as directed. |
| 19 | S&F Non skid ceramic coloured 7 to 8 mm thick area of each tile exc 0.18 sqm but n.exc 0.38 Sqm as in vertical surface such as skiritng dado etc .and jointed in neat cement slurry and pointed in white or coloured cement to match incl plaster (backing coat) of cement mortar CM 1:4,10mm thick |
| 20 | S&F of glazed ceramic coloured tiles300x450x7mm thick set and jointed in neat cement slurry and pointed in coloured cement to match including 10 mm thick in cm (1:4) in vertical surfaces of walls/skirting etc. |
| 21 | Demolition of brick work in cement mortar. |
| 22 | Brick work with sub class \"B\" bricks straight or curved on plan to any radious in half brick thick walls in CM 1:4 complete all as specified. |
| 23 | M&L for Brick work with sub class ‘B’ brick, straight or curved on plan exc 6 m mean radiusbuilt in CM 1:6 complete. |
| 24 | Taking down chowkhats or frame with shutter without taking off shutter from the frame area not exc 1.5Sqm each and removal to store complete all as specified |
| 25 | Taking down chowkhats or frame with shutter without taking off shutter from the frame areaexc 1.5Sqm each and n.exe 4.0 sqm removal to store complete all as specified |
| 26 | Taking down shutters of anydescription exc 1 Sqm and not exc 2 Sqm each |
| 27 | M&L mild steel framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc. using steel conforming to Fe-410 Gde-E-250 complete including drilled for fixing of steel sheeting or other covering; doors, door frame chowkhats etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing including necessary cutting drilling and welding etc complete all as specified and directed. |
| 28 | S&F 35mm thick IInd class hard wood plain framed factory made paneled shutters with (2 panel ) with lock rail and panel of 9mm BWP commercial ply or 12mm veneered particle boardwith commercial veneering on both faces.The size of rail and stile as per IS: 1003 (Part-I) kiln seasoned and chemically pressuretreated complete all as specified. |
| 29 | Solid PVC door frame of size 50 mm x 47 mm made out of 5 mm plain colour PVC sheet reinforced with M S square tubes, S&F in opening as per specification & drawing given in SSR-2004. |
| 30 | S&F 30 mm factory made solid panel PVC door shutter consisting of frame made out of MS tube for top and bottom rail, MS frame shall be covered with heat moulded plain colour PVC “C” channel having strip of 20 mm width stuck inside with solvent cement rail on either side and as gap inset for top rail and bottom rail, welded/sealed to the stiles and rails with suitable PVC sheet beading and joined together with solvent cement supply and fixing in the frame and site as specification all as specified. |
| 31 | Supply & Fixing 100mm size butt hinges medium weight cold rolled mild steel all as specified. |
| 32 | S&F100mm size stainless steelbutt hinges for fixing to PVC doorsall as specified. |
| 33 | Supply and fixing aluminium anodised barrel tower bolts of extruded section 200mm long, complete all as specified and directed. |
| 34 | S&F Extruded aluminium alloy handles, fabricated type,anodised 150 mm in size, complete all as specified and directed. |
| 35 | S&F Aluminium alloy, anodised,sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed 250mm long, complete all as specified and directed. |
| 36 | S&F floor door stopper of aluminium alloy body and tongue, anodised with hard drawn steel spring fixed in floor overall length of cover plate 150mm complete all as specified and directed. |
| 37 | M&L for preparation of new wood surface of any description over 10 cm width or grith and applying two coats of synthetic enamel paint over a coat of pink primer, complete all as specified and directed. |
| 38 | M&L for preparation of new steel surface of any description over 10 cm width or girth and applying two coats of synthetic enamel paintover a coat of red oxide zinc chrome primer complete all as specified |
| 39 | Dismantling wall and ceiling boards (fiber, pulp, insulation etc) or insulation boards/slabs/blankets, any thickness including cover fillet complete all as specified and directed. |
| 40 | Supply & Fixing false ceiling with Everest Fibre Cement Designer tile Ivory painted (High Pressure Steam Cured) of 4mm thickness (as per IS: 14862) of size 595x595 mm and any one of the desin (occeanic, lake & hill, cascade or electra) in true horizontal level,suspended on inter locking metal grid of hot dipped galvanized steel sections (galvanized @ 120 gms, both side inclusive) consisting of main \"T\" runner with suitably spaced joints to get required length, and 15x32mm made from 0.30 mm thick sheet, and cross \"T\" of size 15x32mm made of 0.30 mm sheet, spaced between main \"T\" at 600mm c/c to form a grid of 600X600mm and wall angle of size 15x20mm made of 0.30 mm thick sheet and laying false ceiling tiles in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixures,smoke detectors etc.Main \"T\" runners to be suspended from ceiling using GI soffit cleats fixed to existing rafter, purlin,etc with dash fasteners,GI adjustable rods of 3mm dia with gavanised Butterfly level clips,spaced at 1200 mm c/c along main T, bottom exposed width of 15mm of all T-sections shall be centra black pre-painted with polyester paint, and having a load bearing capacity of 12 kg/sqm, all complete at all heights as per direction of Engineer-in-Charge. |
| 41 | S&F in repair 6mm thick Asbestos cement plainbuilding boards, fixed to timber framework with screws. |
| 42 | S& F 1000ltrs rotationalmoulded polythine water storage tanks( cylinder vertical with closed top) hoisted and fixed in position including ball brass valves,high pressure with polythene float and flynut complete screw for iron pipe or brass ferrule all as specified in SSR Part-I. |
| 43 | S&F 20mm Ball valves high pressure of PTMT with epoxy coated Aluminium rod & highdensity plastic ball screwed for iron pipe and fixed. (Minimum weight 15mm-142gms/ 20 mm - 210 gms./ 25mm-455gms/ 40mm - 690 gms)complete all as specified. |
| 44 | S&F in repair 20mm Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed, complete all as specified and directed. |
| 45 | Taking down eaves gutters and rainwater pipes/sewage pipe (any size or pattern ),including all fittings,heads,shoes,bends,swan necks etc.including cleaning or refixing or removal to store. |
| 46 | S&F PVC pipe (SWR) single socketed in any length with rubber ring joint, laid to wall 110mm dia |
| 47 | S&F PVC pipe (SWR) single socketed in any length with rubber ring joint, laid to wall 75mm dia |
| 48 | M&L PVC (SWR) Junction Single \"T\" equal or unequal 110mm dia |
| 49 | M&L PVC (SWR) Junction Single \"T\" equal or unequal 75mm dia |
| 50 | M&L 75mm PVC (SWR)PVC (SWR) floor/nahani trap, plain with grating including jointing with solvent cementfixed in repairs complete all as specified and directed. |
| 51 | S&F PVC(SWR)bends any radius 110mm dia |
| 52 | S&F PVC(SWR)bends any radius 75mm dia |
| 53 | S&F PVC(SWR) vent cowl 75mm dia |
| 54 | S&F PVC(SWR) vent cowl 100mm dia |
| 55 | Taking down GI Tubing 15 mm dia and connection including cleaning for refixing or removal to store |
| 56 | All as per Ser item No 55.00 above but 20 mm dia GI tubing |
| 57 | S&F GI tubing 15 mm bore fixed to wall/ ceiling or flooras specided. |
| 58 | All as per Ser item No 57.00 above but 20 mm dia GI Tubing. |
| 59 | S&F in repairs stop valves 15mm cast copper alloychromium plated fancy type , screwed down , high pressure ,with crutch or butterfly handle ,screwed both ends for iron pipe or for union and fixed complete all as specified and directed |
| 60 | S&F in repairs 15mm dia bore Angle valves two way cast copper alloy chromium plated fancy type with long shank & cup. Complete all as specified and directed by Engineer-In-Charge. directed. |
| 61 | S&F in repair bib taps fancy typeISI marked cast copper alloy chromium plated suitable for 15mm bore pipes with crutch or butter fly handle screwed for iron pipe or brass ferrule all as specified . |
| 62 | S&F pillar taps, brass, with capston heads, fancytype, chromium plated, screwed down high pressure with or without lettered \"Hot\" or \"cold\" with long screwed shanks and flynuts screwed for 15mm bore iron pipe andfixed in repair, complete all as specified and directed. |
| 63 | S&F PVC connection 450 mm long suitable for 15 mm bore pipe including PTMT nuts complete all as specified and directed. |
| 64 | S&F chromium plated grating 125 mm dia circular of approved make and fixing with cement mortar 1:3 on Nahani trap or floor trap complete all as specified and directed. |
| 65 | S&F PVC waste pipe 32/50 mm dia flexible for wash handbasin/urinal completecomplete all as specified and directed. |
| 66 | S&F in repairsVitrous china squatting pan Orissa pattern of size 580x440 mm complete all as specified. |
| 67 | S&F in repair vitreous china wash down water closet panwhite excluding fixing bolts, flushing cistern and flush pipe with and incl \"P\" or \"S\" trap and making good to floor to match with existing all as specified and directed. |
| 68 | S & F in repair Jet spray with holder for EWC 1.5mtr long suitable for 15mm dia for iron pipe or for brass ferrule all as specified & directed. |
| 69 | S&F in repair brass chromium plated health faucet with flexible tube of suitable length fixed on water closet (English type) complete all as specified. |
| 70 | S&F in repairs plastic seat cover white for water closet pedestal pattern closed patter with flat bottom fixed with mild steel chromium plated or aluminium hinging device complete all as specified. |
| 71 | S&F in repairvitreous china wash hand basin, white,flat back size 550 x 400 mm including one number brass CP waste coupling, 32 mm dia, brackets 2 numbers including cutting for and pinning in ends of brackets complete all as specified and directed. |
| 72 | S&F in repairsin repairs Vitreous China Half stall urinal complete including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60 mm long brass screws, pointing around urinal back in cement. |
| 73 | S&F Vitreous Chinaurinal partition white of size 310x700mm complete all as specified and directed |
| 74 | S&F in repairsPVC low level valve less symphonic action type flushing cistern of capacity 10 ltr including float valve, brackets, PVC short bend complete all as specified |
| 75 | S&F in repairs bevelled edge looking mirror of selected quality glass, 5.5 mm thick of size 1500 x 750 mm,PVC moulded case mounting on 6 mm thick AC building board or commercial ply wood on back and fixed to wooden plugs with chromium plated brass screws and cup washers complete all as specified and directed |
| 76 | S&F in repairs bevelled edge looking mirror of selected quality glass, 5.5 mm thick of size 450 x 600 mm,PVC moulded case mounting on 6 mm thick AC building board or commercial ply wood on back and fixed to wooden plugs with chromium plated brass screws and cup washers, fixed in repairs, complete all as specified and directed |
| 77 | S&F in repair, Sheet Glass Shelf 500x125mm (with brass brackets)and fixed to wooden plugs with chromium plated brass screws and cup washers, complete all as specified and as directed |
| 78 | S&F in repair towel railchromium plated brass 600 mm long fixed with and incl CP brass screw |
| 79 | S&F in repair Towel Ring of PTMT fixed with and including Chromium plated brass screws and wooden/plastic cleats (Minimum weight 90 gms) |
| 80 | S&Fin repair Soap dish stainless steel chromium plated fixed with brass screws andrawl plug complete all as specified . |
| 81 | Taking down carefully aluminium / copper point wiring (light / fan / socket or power) while not disturbing existing conduit complete including fitting such as switches, ceiling roses, socket, light fittings, regulators etc complete and making good disturbed surfaces of walls and floors . |
| 82 | Taking down sub main wiring of two single core PVC cable PVC insulatedANY CAPACITY including conduit or wooden batten and remove from the site of work and making good the disturbed surfaces of wall or floor etc. as directed by Engineer-in-Charge. |
| 83 | Taking down main switch / DB and making good the disturbed surface as directed by Engineer-In-Charge. |
| 84 | M&L for point wiring with 1.5 sqmm, PVC insulated but sheathed, stranded copper conductor single core FRLS cable, IS-694 marked, drawn through and including non metallic rigid PVC concealed conduit medium grade 20mm dia (minimum) or higher size as specified and cutting chasing on wall complete with all PVC conduit accessories such as socket, elbow, junction box, bell mouth, reducer, bend and flexible conduit etc/ fittings ISI marked for modular fittings andbrass screws and cup washers including 1.5 sqmm stranded copper conductor PVC insulated FRLS cable green in colour as continuous earth conductor connected to common earth and earth dolly with all accessories complete all as specified and directed.Note : Cost of Metal boxes and modular accessories like cover plates will be paid seprately in respective items)(a)Fan point/ exhaust fan point / one light point / bell/ buzzer controlled by one switch/ bell push. |
| 85 | (b) One socket outet point 5 amps on the same board. |
| 86 | (c) One socket outet point 5 amps on the independent board. |
| 87 | All as Ser item 84.00 here in before but with 2.5 sq mm wire and earth wire (green colour) of 2.5 sq mm for 3 Pin 15 Amp modular type socket outlet. |
| 88 | Supply and fixing modular metal flush box 3 module complete all as specified and directed. |
| 89 | Supply and fixing modular metal flush box 4 module complete all as specified and directed. |
| 90 | Supply and fixing modular metal flush box 6 module complete all as specified and directed. |
| 91 | Supply and fixing modular metal flush box 8 module complete all as specified and directed. |
| 92 | Supply and fixing modular metal flush box 12 module complete all as specified and directed. |
| 93 | Supply and fixing modular white cover plate with frame, 3 module complete all as specified and directed. |
| 94 | Supply and fixing modular white cover plate with frame, 4 module complete all as specified and directed. |
| 95 | Supply and fixing modular white cover plate with frame, 6 module complete all as specified and directed. |
| 96 | Supply and fixing modular white cover plate with frame, 8 module complete all as specified and directed. |
| 97 | Supply and fixing modular white cover plate with frame,12 module complete all as specified and directed. |
| 98 | Supply and fixing modular Dummy plate complete all as specified and directed. |
| 99 | Supply and fix in repair Modular switch 6 Amps single pole one way as per existing make & model/ as per sample . |
| 100 | Supply and fix in repair Modular switch 16 Amps single pole one way as per existing make & model/ as per sample . . |
| 101 | Supply and fix Modular multi socket 3 pin and 2 pin 6 Amps round and flat as per existing make & model/ as per sample . |
| 102 | Supply & fixing ceiling roses surfaces bakelite two three terminals 65 x 50 mm all as specified. |
| 103 | Supply and Fixed single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB of cap 20A complete all as specified and directed. |
| 104 | Supply & fixingof 20 Watt Batten luminaire with Polycarbonate Housing with high quality opal finish diffuser.The luminaire should have a CRI > 80 and CCT of 6500K. The luminaire shall be compliant with IP20 and IK02 classification.Luminaire shall be designed to emit at least 2000 nominal lumens and an System efficacy of at least 100 lumen/watt and maximum system wattage of 20 Watts. The luminaire shall be designed so as to ensure lumen depreciation of up to 30% over 50k burning hours @ design ambient temp 45 deg C. The electronic driver used shall have a power factor >0.95 and THD <10% and suitable for an operating voltage range of 140-270V AC. Manufacturer shall have inhouse lab approved by NABL or ministry of science of govt of India. LM 79 and LM80 reports need to be submitted from a NABL/UL accredited lab to verify above parameters. |
| 105 | S& F in replacement LED tube set (fitting) 20 Wuse and through type withinternal surge protection device of 4 KV with voltage band 140-280V with LED rod with fixture box type and making electrical connection to ceiling rose all as directed |
| 106 | S&F SITC of high-quality LED Flood Light with a minimum system lumen of 12000 Lm and system wattage not exceeding 100 W with a nominal efficiency 120 lumen/watt. CCT of 5700K with CRI >70. The housing should be of pure polyester powder coated die-cast aluminum with high efficiency LEDs as lighting source. The fitting should have PC reflector for maximum output and PC Lens for symmetric distribution & tempered protective Toughened Glass with IP66 protection and impact resistance of IK07 with PF > 0.95. Lifetime of 50K hours @L70. The Luminaire should have Powered by integral, Isolated LED electronic driver (SMPS based constant current supply) with lower THD, Output Open / Short Circuit protection, Phase to Phase protection (Operation at 440 V AC), Over Voltage protection, Surge Voltage protection upto 6 kV.Manufacturer shall have inhouse lab approved by NABL or ministry of science of govt of India. LM 79 and LM80 reports need to be submitted from a NABL/UL accredited lab to verify above parameters. |
| 107 | S&F in replacement highbay LED 120 watt with PDC housing suitable for ceiling (Suspended) mounting with system efficacy upto 150 lm/W and connecting electrically to ceiling rose using PVC insulated and overall sheathed flexible copper conductor cable of suitable size complete all as specified and directed. |
| 108 | Supply & Fixing MCB single pole, 240 volts, 6 to 32 Ampere, rupturing capacity 10 KA, ‘B’ curve type |
| 109 | S & F MCB SPN, 240 volts, 40 to 63 Ampere, rupturing capacity 10 KA, ‘B’ curve type |
| 110 | Supply and fix Sheet metal DB,double door,SPN 8 way for MCB, 240 volt with 200 amps rated bus bar , neutral bar / connectors suitable copper thimbles , lugs etc complete all as specified and directed. |
| 111 | Supply and fix MCCB 100 Amps 4 pole415 Volt,25 KA breaking capacity |
| 112 | Supply and fix MCB DB, TPN 6 way double door Vertical type suitable for mounting of MCCB as incomer with suitable 200 amps rated bus bars , Neutral links , blanking plates |
| 113 | S/F MCB TPN63Amps 415 volts |
| 114 | Supply and fix MCB DB, TPN 4 way double door with suitable 200 amps rated bus bars , Neutral links , blanking plates |
| 115 | Supply and fix Sheet metal DB,SINGLE door,SPN 4 way for MCB, 240 volt with 200 amps rated bus bar , neutral bar / connectors suitable copper thimbles, lugs etc complete all as specified and directed. |
| 116 | M & L for sub main wiring with 1100 volt grade two single core FRLS Wire PVC insulated and unsheathed cable with stranded copper conductor 10 sqmm drawn into and including electrical grade PVC conduit not less than 25 mm dia with IS 9537 (Part-III) 1983 mark, or relevant ISI mark with all accessories fixed concealed including chase cutting in brick/ stone masonry for fixing conduit and making good the disturb surfaces of wall as per existing including 10 sqmm multi - stranded copper conductor as earth wire in green colour complete all as specified and directed.Note : Four runs of 10 sqmm PVC FRLS multi stranded copper cable wire and One run of 10 sqmm PVC FRLS multi stranded copper cable earth wire and One run (01 meter) PVC conduit of suitable size ISI mark will be measured and one unit length. |
| 117 | M&L for concealed conduit sub main wiring of2 run ofsingle core multi stranded FRLS PVC insulated and unsheathed copper conductor as per IS-694 FR cable red and black colour of size 6 sqmm1100 volts grade with 6.0 sqmm multi strand copper conductor PVC insulated and unsheathed cable in green colour earth continuity wire connected to common earth dollyin PVC pipe including cutting chasing complete with all accessories as specified and directed. |
| 118 | M&L for submain wiring with two RUNS of single core 4 sqmm for main wire and one run of single core 4 sqmm as earth wire of stranded FRLS copper conductor PVC insulated unsheathed cables drawn through and including concealed conduits in wall and necessary cutting and chassing forrigidPVC conduit ISI marked not less than 20 mm dia andall accessories complete all as specified & directed. |
| 119 | Taking down unserviceable Cable of any size as directed by Engineer-in-Charge. |
| 120 | Supply and laying XLPE insulated , armoured electric cable heavy duty with aluminium conductor , 1100 volts UG cable of size 3.5 Core 35 Sqmmm, |
| 121 | Excavation in trenches in soft/lose soil not exceeding 1.5 Mtr wide and not exc 1.5M depth for laying of UG cables and getting out all as specified and directed. |
| 122 | Returning, filling, including spreading, levelling, watering and well ramming in layers not exc 25cms thick of soil complete all as specified and directed. |
| 123 | M & L river sand in trenches as cable cushioning 8 cm below the cables and 15cm above the cable which is to be punned down to 10m all as specified and directed.only punned thickness will be measured. |
| 124 | Removing the surplus excavated materisl/soil to a distance not exc 50Mtrs and depositing, where directed at a level not exceeding 1.5 Mtr above the starting point all as specified and directed. |
| 125 | Supply and lay burnt bricks sub class \"B\" standard size laid across the cable in trenches as protection to the cable all as specified and directed. |
| 126 | Supply & fix of complete Motorization of Existing manually operated door - Electro-mechanical Motor Gear Drive ( 3 Phase, 3 H.P ) Unit with Idler braking system, manual de-clutching system, Motor foundation, Fully enclosed weather protected control Panel duly with Overload protection, MCB, Motor protection, Emergency Switch, LED push button switch for different operation for opening-closing -stopping of door leafs shall be provided for controlled uniform speed preferably with low speed @ 6 to 7 meter per minute before stopping at required destination of each door leaf, festoon type cable carrier with rope wire arrangement, tightener, fire rated electric cable minimum 2.5 mm thick from motor unit to control panel. Other fire rated electric cables minimum 0.75 mm for limit switches to control panel, cable fixing MS conducting with bends, clamps complete with nut bolts & other hardware. Hooter cum blinker for safety of door, Idler assemblies, Wire brush Track cleaner at bottom in each leaf, heavy duty cleat to protect from De-Railing, Manual de-clutching arrangement in case power failure. EPMD, shape gasket duly fixed with Aluminium Strip, Flat 3 mm Neoprene soft rubber fixed at edges of each leaf to cover gap between two leafs to protect inside hanger premises from rain & dust. For extra safety heavy duty buffer stopper at extreme end of each side parking bay for each leaf. The speed of door should be 6 to 7 meter per minute, incl. repair of existing Manual opening any type & size complete all as specified & directed. Complete Scope of Work:-(a) Aligning of all leaf without damage and refixing it after making it straight and aligned. (b) Repairing and services of all bottom wheel and re-fixing it and Repair and services of all top roller wheels and re-fixing it.(c) Aligning of top guide & Aligning of bottom track.(d) Fixing L shape MS of size 25 x 3 mm at both edges of bottom track to protect PCC work. (e) Fixing of Auto track cleaner ( wire brush) at bottom of each leaf. (f) Fixing of buffer ( hard rubber as shock absorber) at each end of door leaf & Fixing of cleat ( anti-falling arrangement at top of each door leaf).(g)Fixing of Soft Neoprene rubber between Gaap of two leafs in vertical portions to prevent dust-rain from outside & Fixing D shape neoprene rubber between two leaf at centre to avoid metal to metalcontact at closing.Note 1 : Any minor items reqd for the work are deemed to inclusive rate quoted by the contractor. Note 2 : The price offered is inclusive of all above work.Note 3 : Guarantee- 24 months from Complete Erection.Make:- AREEN ENTRANCE AUTOMATION PVT LTD, JASOLA, NEW DELHI-( Mob9810124819)/GANDHI AUTOMATION PVT LTD, GOREGAON, MUMBAI/ CONCORD TECHNOLOGIES PVT LTD, BANGLORE. |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |