| 1 | Steel work in tubular trusses including special shaped washer etc complete using ERW or induction butt welded tubes conforming to IS-1161-1979 grade St-240, including shop coat of zinc chrome red oxide primer complete all as specified and directed. |
| 2 | Rolled sections as in main and cross beams, hip and jack rafters,purlins where connectedto common rafters and running rails and guidesforsliding doors, fixedwithangle cleats or other connecting plates, conforming to Fe-290 Gde E165, all as specified and directed. |
| 3 | Two coats of synthetic enameled paint on steel and iron surfaces over 10 cm width or girth including preparation of new surfaces over a coat of red oxide primer complete all as specified & directed. |
| 4 | Excavation in post holes not exc 0.50 cum, getting out, returning filling in and ramming earth, watering and removing surplus soil not exc 50 m in any type of soil complete all as specified and directed. |
| 5 | PCC 1:4:8 type D-2 using 40 mm graded stone aggregate asin sub base foundation filling and mass concrete of etc inclding post holess complete all as specified and directed. |
| 6 | Cement concrete type B-0, 1:2:4 using (12.5 mm graded crushed stone aggregate) as in roof kerbs or mud stops, rounded or chamfered on edges in lintels upto 1.5m clear span, cills, steps, seismic and other similar bands, plinth courses, parapets and railings upto 60 cm in height, copings, bed plates, water troughs and the like including weathering, slightly rounded or chamfered angles and throating, including the use of forms or moulds with plain faces complete all as specified and directed. (Cement concrete item shall be reinforced, where ordered. Reinforcement shall be measured and paid separately). |
| 7 | Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed. |
| 8 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and as directed. |
| 9 | Coloured vitrified ceramic tiles, light shade,10mm thick (square / rectangular) , area of each tiles n.exc 0.36 sqm, in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tile, over15mm thick screed bed in cement mortar 1:6, complete all as specified and directed. |
| 10 | All as per serial item 9but as in skirting/ daddo including,over & including 10mm thick rendering in cement mortar 1:4 complete all as specified and as directed. |
| 11 | Glazed coloured ceramic tiles in vertical surface 300mm x 450mm x 7mm thick, set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tile, over and including 10mm thick rendering in cement mortar 1:4, complete all as specified and directed. |
| 12 | Non skid, first quality ceramic coloured tiles, 7 to 8 mm thick (square/ rectangular) area or each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tile, over and including 15mm thick screed bed in cement mortar 1:6 complete all as specified and directed. |
| 13 | Roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust etc complete all as specified. |
| 14 | Taking down chowkats or frame not exc. 1.5 Sqm with shutters, without taking off shutters from the frame,complete all as specified and directed. |
| 15 | Taking down chowkats or frame exc. 1.5 Sqm and n exc 4 Square metre with shutters, without taking off shutters from the frame,complete all as specified and directed. |
| 16 | Taking down shutter of any description exc 1 Sqm but n.exc 2 Sqm each complete all as specified and directed. |
| 17 | Powder coated aluminium (minimum thickness of powder coating 50 micron) for shutters/frame of doors, windows & ventilators/ partitions including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber/neoprene gasket required (Fittings shall be paid for separately) with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ paneling, C.P. brass/ stainless steel screws all complete as per architectural drawings and the directions of Engineer-in-charge. |
| 18 | Powder coated aluminium window andventilator shutters, side hung typewithout sash bars, aluminium sectionsweighing 0.55 kg/m includingnecessary joining cleats, glazing clips,rubber packing, anodised aluminiumsnap beading, screws, anodisedaluminium fittings such as peg stays150mm long (1 no.). hinges type B-21100mm long (2 no.) suitable handle (1 no.) completeallasspecified all complete as per architectural drawings and the directions of Engineer-in-charge. |
| 19 | Anodised aluminium grill (anodised transparent or dyed to required shade according to IS: 1868 with minimum anodic coating of grade AC 15) ofapproved design/pattern, with approved standard section and fixed to the existing window frame with C.P. brass/ stainless steel screws @ 200 mm centre to centre, including cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodised aluminium standard section around the opening, all complete as per requirement and direction of Engineerin-charge. |
| 20 | 4.80mm thick ordinary quality tinted glass,fixed to aluminium frame workin panels not exc 0.5 Sqm in each pane, complete all as specified & directed. |
| 21 | 4.80mm thick ordinary quality tinted glass,fixed to aluminium frame workin panels exc 0.5 Sqm in each pane, complete all as specified & directed. |
| 22 | Stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm including fixed with stainless steel wire staplescomplete all as specified & directed. |
| 23 | 1.50 mm thick Fibre glass reinforced translucent plain coloured sheeting withfixed with coach screw and washer in roof, wall, fencing etc complete all as specified and as directed. |
| 24 | Framed work such as grills, gratings etc., with ends of bars shouldered and/or riveted, or forget into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe 410-0 or Fe 310-0,all as specified and directed. |
| 25 | Fibre glass reinforced 35mm thick door any design and any pattern fixing with hinges panels will be constructed of two sheets of 1.20mm fibre glass sheet bounded to 3/4 inch core material panel thickness will be 25mm and aluminium frame surronds the perimetre of the panel and measures and approved design including complete fitting handle, twoer bolt, door stopper etc complte all as specified and directed. |
| 26 | Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid decorative type flush door shutter of size 30mm thick comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2 , modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant. WPC to be laminated with PVC foil of minimum 14 microns thick of approved design pasted with hot melt adhesive on both faces of shutter and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer-in- Charge |
| 27 | 150 mm size aluminium anodized, barrel tower bolt (ISI Marked) of extruded section complete all as specified and directed. |
| 28 | 150mmExtruded aluminium alloy handle fabricated type,complete all as specified and directed. |
| 29 | Angular stop cock, fancy type, cast copper alloy chromium plated, screwed down,screwed both and for iron pipe or for union, suitable for 15mm bore pipe, fixed as in repair complete all as specified and directed. |
| 30 | Vitreous china, wash down water closet pan, white, Pedestal pattern WC with ‘P’ or ‘S’ trap, with all fittings and connection, fixed as in repairs complete all as specified and directed. |
| 31 | Sinks with drainage board made of stainless steel 1mm thick kitchen or laboratory with plugs, washers and waste; including bedding in cement mortar to dwarf wall or including fixing cantilever bracket to connecting union to pipe overall size 915mm x 460mm bowl size 410mm x 330mm x 160mmfixed in repairs complete all as specified and directed |
| 32 | Plastic water closet seat cover white closed pattern with flat bottom mild steel chromium plated or aluminium hinging device, fixed as in repairs, complete all as specified and directed. |
| 33 | Health faucet (ABS Body) mild steel chromium plated suitable for 15 mm dia pipe with 1.25 metre long flexible tube and ABS wall hook including making connections and fixed in position complete in all respect, fixed as in repair complete all as specified and directed. |
| 34 | Wall / sink mixer for mixing hot & cold water, chromium plated suitable, and screwed down for 15mm bore GI pipe or union, fixed as in repaircomplete all as specified and directed. |
| 35 | WHB mixer, for mixing hot or cold water, screwed down for pipe and fixed, suitable for 15mm bore pipe fixed as in repaircomplete all as specified and directed. |
| 36 | Harrison rails 25 mm size, mild steel, chromium plated with fixing brackets, stops, rollers etc. for curtain rod inclulding taking down defective bracket complete all as specified and as directed. |
| 37 | Towel rail 600mm long ofmild steel, chromium plated fixed with and including chromium plated brass screws and wooden / plastic cleats, fixed as in repair complete all as specified and directed. |
| 38 | Chromium plated,shower rose with swivel joints 125mm dia with arm and fixing to steel pipe 15mm bore, fixed as in repaircomplete all as specified and directed |
| 39 | Sheet glass shelf assembly consisting of 5.5mm thick sheet glass 12cm wide with CP bracket guard and railing 60cm long, fixed as in repair complete all as specified and directed. |
| 40 | PVC connections 15 mm size with PTMT nuts of length 450 mm , fixed as in repair complete all as specified and directed. |
| 41 | Vitreous china Single piece EWC (one piece), minimum size 715 x 335 x 715mm, , snow white colour, S-trap with integraed flushing cistern, including slim soft close seat cover , fixed as in repairs, complete all as specified and directed. |
| 42 | Excavation in trenches not exceeding 1.5m wide and n.exceeding 1.5m deepfor foundation etc or for shaft, wells, cesspits, manholes, pier holes etc not exceeding 10 sqm on plan and getting out in soft and looseof soil all as specified & directed by Engineer-in-Charge. |
| 43 | Returning filling in including spreading, levelling, watering and well ramming in layers not exc.25cm thick each layer of soil all as specified. |
| 44 | Removal of excavated material to distance exc 50 metre but not exceeding 250 metre and depositing where directed at a level not exceeding 1.5 metre above the starting point in soil, complete all as specified and directed. |
| 45 | Brick work with sub class ‘B’ bricks old size bricks, straight or curved on plan exc 6 metre mean radius built in cement mortar 1:4 complete all as specified & directed. |
| 46 | Rendering 15mm thick plaster in cement mortar 1:4 on fair faces of brick wall or on concrete surfaces and finishing the surface fair and even without using extra cement and providing necessary scaffolding , safety precautions and other requisite arrangements all as per site requirement complete all as specified & directed. |
| 47 | Precast cement concrete louvres and jallies, type B-0, 1:2:4, using 12.5 mm graded stone aggregate, 35 mm thick (measured solid), set in cement mortar 1:4 including all mouldings but excluding frame including dismantling of old jalli complete all as specified and directed. |
| 48 | Precast reinforced cement concrete type B-l, 1:2:4 (20 mm graded aggregate) in precast posts, fencing posts, straining or terminal posts, struts etc. for fencing, average sectional area n exc 100 sq. cm, with or without chamfered angles and flat, splayed, rounded or mitred tops as directed and fixed complete all as specified and directed. |
| 49 | Applying wall care putty on newexternal surfaces of bldg(average thickness 2mm as required for desired smoothness and leveling of surfaces in two or more layers) incl necessary scaffolding and safety arrangementsincluding sand papering after filling the putty to make surface smooth and ready to receive exterior paintingand applying two coats of exterior emulsion paint over one coat of exterior wall primer(all as per manufactures instructions) complete all as specified and directed. |
| 50 | Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc. complete all as specified and directed. |
| 51 | Material and labour forpoint wiring with approved colour code multi stranded copper conductor, PVC insulated and unsheathed FRLSH cable of size 1.5 Sqmm ,1100 volts grade, two run of single core cable for phase & neutral and one run of single coremulti stranded copper conductor, PVC insulated and unsheathed FRLSH cable of size 1.5 Sqmm ,1100 volts grade for earth continuity conductor to common earth and connected to earth dolly in and including new concealed PVC conduit terminated on and including new modular sunken box and suitable size of frame, cover for mounting switch, socket and regulator fixed on surface flush with wall , comprising ofOne light /bell/buzzer point controlled by one switch or one fan point controlled by one switch &fan regulator, complete all as specified and directed. Note : Unit rate is inclusive of making good the disturbed surfaces by provding by wall putty/POP after mason work and finshing to match the original and nothing extra shall be paid on this account.Note :Unit rate is inclusive of cutting chases in wall /foor/PCC and making good the disturbed surfaces to match the original and nothing extra shall be paid on this account. |
| 52 | All as per serial item 51 herein before but for socket outlet 3 pin 6Amps on same board complete all as specified and directed |
| 53 | All as per serial item 51 herein before but for socket outlet 3 pin 6 Amps on independentboard complete all as specified and directed |
| 54 | All as per serial item 51 herein before but One socket outlet three pin ,6/16 Amp, independent board, with 2.5 Sqmm (nominal area ) FRLSHcable & 2.5 Sqmm (nominal area ) cable as earth continuity conductor |
| 55 | Switch modular type (ISI marked), single pole, 6 Amps, one module(ISI marked), complete all as specified & directed. |
| 56 | Switch modular type (ISI marked), single pole, one way 6 Amps two way, one module(ISI marked), complete all as specified & directed. |
| 57 | Switch modular type (ISI marked), single pole, one way 16 Amps, one module(ISI marked), complete all as specified & directed. |
| 58 | Socket shutters outlet 6 Amp modular type multi purpose two module, inlet multi socket for all pin (ISI marked), complete all as specified & directed. |
| 59 | Socket shutters outlet 2 in 1 pin 6/16 Amp modular type multi purpose combined 2 module (ISI marked), complete all as specified & directed. |
| 60 | Modular switch type stepped fan regulator, single pole, 230 volt two module complete all as specified and directed. |
| 61 | Modular switch type bell push, single pole, 230 volt one module,(ISI marked) complete all as specified and directed. |
| 62 | Electric Bell, multi music type, AC, 230 volts, single pole all as specified and directed by Engineer-in-charge. |
| 63 | Ceiling rose, PVC or polycarbonate of size 65mmx50mm three terminals (ISI marked) all as specifiedand directed by Engineer-in-charge. |
| 64 | Lamp holder, PVC/Polycarbonate type with back plate modular type fixed on wall suitable for batten fitting ,complete all as specified and directed. |
| 65 | LED Bulb 09 watt self ballasted Retrofit type lamp with PBT body shell and DC diffuser CCT 6500 K complete all as specified and directed. |
| 66 | LED Lights fitting 1 x 18/20 Watt, 4 feet ,220V AC decorative typeincluding fitting fixed on wall/ceiling and connecting up complete with flexible cable white of suitable size and making necessary connection complete all as specified and directed. |
| 67 | LED Mirror Lights fitting 17 watt cool day white of approx size near to 534 x 93 x 33 mm , 220V AC decorative/model ultorn type including fitting fixed on wall/ceiling and connecting up complete with flexible cable white of suitable sizeand making necessary connection fixed as in repair complete all as specified and directed. |
| 68 | LED Industrial outdoor type Bulkhead luminaires,IPrating not less than 45, highly resistant to dust and water1 x 9/10 Watt fitting in engineering plastic housing with clear prismatic diffusercomplete with all accessories and connecting up with flexible cable white ofsuitable size and making necessary connection fixed as in repair complete all as specified and directed. |
| 69 | LED 18W Surface mounted indoor type back lit downlighter suited for any modern workspace of size not less then 6-8\"\" round/square as per sample fixed as in repair complete all as specified and directed. |
| 70 | Decorative, wall mounting, brushed nickel finish fixture with Single opal glass diffuser suitable for and incl 1 x 9W LED lamp B22 base, perfect ambience for living/bedroom fixed as in repair complete all as specified and directed. |
| 71 | Decorative, wall mounting, brushed nickel finish fixture with Double opal glass diffuser suitable for and incl 2 x 9W LED lamp B22 base, perfect ambience for living/bedroom fixed as in repair complete all as specified and directed. |
| 72 | Modern Bedside wall mounted reading fitting LED 2 Watt, adjustable head for better beam and focus, touch control switch, uniform light LED integration for right ambience, as per samplecomplete all as specified and directed. |
| 73 | Decorative, wall mounting fixture, in durable plastic body & designer mesh in gold finish suitable for 9 W LED lamp pettren Glaze type as per sample fixed as in repair complete all as specified and directed. |
| 74 | LED building security light fitting 1 x 35 Watt new generation energy saving and environmental friendly long life LED street light made up of pressure diecast aluminium housing with high power LED as lighting source and lens embedded PC cover having top opening seperate driver compartment with IP65 protectionincl mounting bracket of suitable size and connection fixed as in repair complete all as specified and directed. |
| 75 | Taking down carefully old unserviceable ceiling fans/wall fan /exhaust fans complete, removing its blade and deposit to the MES Store yard for serviceabilty check and further board of action. |
| 76 | Hanging/fixing only serviceable ceiling/exhaust fan any make/ sweep and connecting up with existing electric circuit complete received from MES Store Yard all as specified and directed. |
| 77 | Ceiling fans 1200 mm sweep, AC 230 V complete with blades, down rods andconnected accessories, Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with (BLDC) brushless direct current motor with remote control and connection complete all as specified and directed. |
| 78 | Exhaust fans for kitchen with louvers 300 mm sweep, 1400 RPM, Heavy duty single phase 240 Volts, AC 50 Hz, steel body and connecting up including louvers including making necessary opening on stone /brick masonry wall of suitable size, finishing it properly and making good with matching colour with the surroundings provision of cable 3 core of suitable size from ceiling rose to fan complete all as specified and as directed. |
| 79 | Wall Mounted fans for kitchen dacorative type400 mm sweep, 230V AC Supply, 50 Hz, high performance, smooth oscillation, copper wound motor made of sturdy Engineering plastic and metal ribs guard completeas per complete all as specified and as directed. |
| 80 | Single pole and neutral sheet metal enclosure with a two pin and earth plug and socket complete with one number single pole MCB 20 Amps , 240 Volts for AC/Geyser point complete all as specified and as directed. |
| 81 | Taking down carefully Geysers of any capacity and removing with materials to store for keeping in safe custody by the contactor and deposit to the MES Store yard check its serviceability and further BER board action as per direction. |
| 82 | Fixing only serviceable Geysers of any capacity and connecting up with existing site as per direction complete received from MES Store Yard all as specified and directed. |
| 83 | Supply , installation, testing and commissioning of electric water heater (Geyser), storage vertical or horizontal type as approved , BEE 5 star rated, 25 litre capacity, 230 volts AC, 50 Hz comprising of high voltage heating element upto 2 KW for instatnt heating, ABS tech/ Engineering thermoplastic body or steel/ metal body with steel inner tank with corrosion resistance coating , rust and shock proofwith and including provision of Pressure relief valve and grouting bolts suitably flushed to wall or any other surfcae including PVC connection & electric connection with 3 core PVC insulated, sheathed, stranded copper conductor cable / flexiable chord with plugcomplete all as specified and directed. |
| 84 | Taking down carefully old copper or aluminium sub main wiring of any Nos of wiring and size with earth wire on wooden batten/ surface conduit/ casing- capping complete with its all accessories and making good disturbed surfaces of wall , floors etc complete all as specified and directed. |
| 85 | Sub main wiring with two singlecore FRLSH PVC insulated and unsheathed cable with copper conductor of size 4 Sqmm (nominal area), 1100 Volt grade(with approved colour coding as per IS) with and including continuous earth wire of size 4 Sqmm PVC insulated and unsheathed FRLSH multi stranded copper conductor 1100 volts grade , and connected to main board drawing throughPVC concealed conduit 25mm size(minimum size), cutting chases in walls for PVC concealed conduit and making good the disturbed surfacesby providing by wall putty/POP after mason work and finshing to match the original surfaces and nothing extra shall be paid on this account all as specified and directed. |
| 86 | Sub main wiring with two singlecore FRLSH PVC insulated and unsheathed cable with copper conductor of size 6 Sqmm (nominal area), 1100 Volt grade(with approved colour coding as per IS) with and including continuous earth wire of size 6 Sqmm PVC insulated and unsheathed FRLSH multi stranded copper conductor 1100 volts grade , and connected to main board drawing throughPVC concealed conduit 25mm size(minimum size), cutting chases in walls for PVC concealed conduit and making good the disturbed surfacesby providing by wall putty/POP after mason work and finshing to match the original surfaces and nothing extra shall be paid on this account all as specified and directed.Note for serial item No 85 & 86 :(i)Two runs of cable, one run of earth wireshall be considered as one running metre(ii)Cutting chases will be measured and paid separtely(iii) colour code shall be Red for phase, Black for neutral and green for earth |
| 87 | Supply and fixing sub main wiring with Four singlecore FRLSH PVC insulated and unsheathed cable with copper conductor of size 10 Sqmm (nominal area), 1100 Volt grade(with approved colour coding as per IS) with and including continuous earth wire of size 10 Sqmm PVC insulated and unsheathed FRLSH multi stranded copper conductor 1100 volts grade , and connected to main board drawing throughPVC concealed conduit 25mm size(minimum size), cutting chases in walls for PVC concealed conduit and making good the disturbed surfacesby providing by wall putty/POP after mason work and finshing to match the original surfaces and nothing extra shall be paid on this account all as specified and directed.Note : (i)Four runs of cable, one run of earth wireshall be considered as one running metre(ii)Cutting chases will be measured and paid separtely(iii) colour code shall be Red for phase, Black for neutral and green for earth |
| 88 | Cutting chases in brick walls, pinning in, making good to facings where required and pointing in cement mortar (1:3) to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc and cutting chases for concealed water tubing or concealed conduit wiring etc and making good, cutting not exceeding 10cm girth Complete all as specified and directed . |
| 89 | Disconnecting the power supplyand taking down carefully by unscrewing from boards fittings and fixtures such as DBs, Junction Box, Panels of any size complete with all MCCB\"s ,MCB\"s etcand removing from site, Complete all as specified and directed . |
| 90 | MCB distribution board, double door, 6 way, TPN flush mounting with provisions for MCBs incomer& outgoing having IP 54 protection complete all as specified and directed by Engineer-in-charge. |
| 91 | MCB distribution Board factory made sheet metal enclosure double door distribution board class IP-43 IK 09 with 200 Amp rated copper bus bar 240 Volts 8 way (2 + 06 way) single pole and neutral link, complete all as specified and as directed. |
| 92 | MCB, Triple pole and neutral 63 Amp 415 volts 10 KA \"C\" series with all incomming/outgoing connections with proper size lugs, complete all as specified and directed by Engineer-in-charge. |
| 93 | MCB, SPN , 240 volt,40 to 63Amps, 10 KA , \"C\" series including connection with suitable size aluminium / copper lugs complete all as specified and directed |
| 94 | MCB, SP, 240 volt,40 to 63Amps, 10 KA , \"C\" series including connection with suitable size aluminium / copper lugs complete all as specified and directed |
| 95 | MCB ,SP , 240 volt, 6Amps to 32Amps, 10 KA , \"C\" series including connection with suitable size aluminium / copper lugs complete all as specified and directed |
| 96 | Earthing complete with galvanized steel earth plate electrode 600mm x 600mm x 6mm buried directly in ground vertically to a depth not less than 2.25 meter below normal ground level (with top edge of earth plate not less than 1.5 meter below ground level) connected to galvanized iron earth lead wire 4mm dia, (main earthing lead ) by means of galvanized bolts, nuts and washers all as shown in electrical plate no 5 of MES Schedule Part-I (1991) with connected to earth test point & to main switch board with & including adequate quantity of charcoal dust and common salt alround earth plate & 15 mm dia GI pipe light grade for earth lead protection pipe for suitable length and GI pipe 20 mm dia light grade for watering pipe with funnel & wire meshincluding necessary earth work and PCC (1: 3 : 6) type C-1 for earth pit and 40 mm thick pre-cast RCC cover in 1 : 2 : 4 type B1 with 3 Nos 8 mm dia TMT bars both ways completeall as specified & directed. |