| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 10-03-2026 | C1 | Date | 31-03-2026 |
| Sl. No. | Item Description |
| 1 | SCHEDULE \"A\" Part-I (Building/Structures) (To be quoted by the tenderer) |
| 2 | Item No 01 : Design and constructionof Offrs married Accn for 04 Offrs with servant Qtrs & garrage complete all as specifiedin soil bearing capacity report, design basis report, drawings and tender documents. |
| 3 | Item No 02 : Design and constructionof married Accn for 88 ORswith garage/ scooter parking complete all as specifiedin soil bearing capacity report, design basis report, drawings and tender documents. |
| 4 | Item No 03 : Design and constructionConstruction of Pump house complete all as specifiedin soil bearing capacity report, design basis report, drawings and tender documents. |
| 5 | Sch \"A\" Part-II (External Electric supply)Lump sum price worked out by the contractor for (External Electric supply) as listed in Schedule \"A\" Part-II against the lump sum price inserted by the MES. |
| 6 | Sch \"A\" Part-III (External Water supply)Lump sum price worked out by the contractor for (External Water supply) as listed in Schedule \"A\" Part-III against the lump sum price inserted by the MES. |
| 7 | Sch \"A\" Part-IV(Road Path Culvert)Lump sum price worked out by the contractor for (Road Path Culvert) as listed in Schedule \"A\" Part-IV against the lump sum price inserted by the MES. |
| 8 | Sch \"A\" Part-V (Sewage Disposal)Lump sum price worked out by the contractor for (Sewage Disposal) as listed in Schedule \"A\" Part-V against the lump sum price inserted by the MES. |
| 9 | Sch \"A\" Part-VI(Area Drainage)Lump sum price worked out by the contractor for (Area Drainage) as listed in Schedule \"A\" Part-VI against the lump sum price inserted by the MES. |
| 10 | Sch \"A\" Part-VII(Compound Wall)Lump sum price worked out by the contractor for (Compound Wall) as listed in Schedule \"A\" Part-VII against the lump sum price inserted by the MES. |
| 11 | Sch \"A\" Part-VIII (Hot water)Lump sum price worked out by the contractor for (Hot water) as listed in Schedule \"A\" Part-VIII against the lump sum price inserted by the MES. |
| 12 | Sch \"A\" Part-IX(Fire Fight System)Lump sum price worked out by the contractor for (Fire Fight System) as listed in Schedule \"A\" Part-IX against the lump sum price inserted by the MES. |
| 13 | Sch \"A\" Part-X (TV connection & conduit for Telephone connection)Lump sum price worked out by the contractor for (TV connection & conduit for Telephone connection) as listed in Schedule \"A\" Part-X against the lump sum price inserted by the MES. |
| 14 | Sch \"A\" Part-XI(Lightning Protection & Aviation light)Lump sum price worked out by the contractor for (Lightning Protection & Aviation light) as listed in Schedule \"A\" Part-XI against the lump sum price inserted by the MES. |
| 15 | Sch \"A\" Part-XII (Demolition of bldg Work)Lump sum price worked out by the contractor for (Demolition of bldg Work) as listed in Schedule \"A\" Part-XII against the lump sum price inserted by the MES. |
| 16 | Note for Srl No 3 to 15The percentage above / below the SSR -2020 (part-II) rates shall be derived from the amount quoted by the contractor against Srl No. 3 to 15by comparing it with the amount inserted / pre- priced by the department and the same shall be applicable for the items of respective schedule |
| 17 | Schedule \"A\" Part-XIII (Miscellaneous items of works) |
| 18 | Special item |
| 19 | Item No04 : Construction of married Accn for 88 ORs(Stilt+5) & (S+6) with garage/ scooter parking as per permanent specification, RCC framed structure in RCC M-25Grade concrete all as specified. |
| 20 | (i) MD for ORs Stilt portion in excess of authorise area |
| 21 | Sewage Disposal |
| 22 | Item No05 : M&L 50 users Conventional RCC Septic tank designed to carry sewage and sullage water, excavation in any type of soil, PCC 1:4:8 below foundation, RCC M-30 Design Mix in Walls, Base Slab,Baffe walls and Roof Slab including beams etc with Vent shaft, manhole openings with cover connection etc., complete with effective depth of 1.5 meter and overall depth of 3 meter for |
| 23 | Item No06 : M&L 150 users Conventional RCC Septic tank designed to carry sewage and sullage water, excavation in any type of soil, PCC 1:4:8 below foundation, RCC M-30 Design Mix in Walls, Base Slab,Baffe walls and Roof Slab including beams etc with Vent shaft, manhole openings with cover connection etc., complete with effective depth of 1.5 meter and overall depth of 3 meter for |
| 24 | Item No07 : M&L 100 users Conventional RCC Septic tank designed to carry sewage and sullage water, excavation in any type of soil, PCC 1:4:8 below foundation, RCC M-30 Design Mix in Walls, Base Slab,Baffe walls and Roof Slab including beams etc with Vent shaft, manhole openings with cover connection etc., complete with effective depth of 1.5 meter and overall depth of 3 meter for |
| 25 | Item No08 : M&L for 3.6 M dia X3.0 M effective depth Soakage wells excavation, in any type of soil, foundation in PCC 1:3:6, walls of honey combed masonry with top ring of M25 concrete incuding intercepting chamber and screen chamber made of Brick masonary in CM, RCC cover slab in M25/ SFRC cover, interconnecting pipes of RCC/DWC complete filled with brick bats of size |
| 26 | Item No09 : M&L for 2.4 M dia X3.0 M effective depth Soakage wells excavation, in any type of soil, foundation in PCC 1:3:6, walls of honey combed masonry with top ring of M25 concrete incuding intercepting chamber and screen chamber made of Brick masonary in CM, RCC cover slab in M25/ SFRC cover, interconnecting pipes of RCC/DWC complete filled with brick bats of size |
| 27 | Compound Wall |
| 28 | Item No10 : M&L for two coats of Apex weather paint on newly plastered surfaces over a coat of primer including preparation of surface complete all as specified and as directed |
| 29 | Item No11 : M&L for Mild Steel ornamental gate 5.50 mtr wide with wocket gate with RCC Column complete all as specified and as directed |
| 30 | External Electric supply |
| 31 | Item No12 : Supply, installation, testing and commissioning of Step downcopper wound transformer of Capacity 200 KVA, outdoor type, PCC Plinth mounted complete with standard fittings and accessories, HT 11 KV 3 Phase, LT 433 volts, 3 Phase 4 wire with off load tappings on HT side to vary secondary voltage within limit, all as per IS:1180-2014, (Level-3) Oil Cooling with fins vector group: DYN 11, incl initial oil fitting complete all as specified incl the following accessories:-a) Three numbers porcelain bushing HT,11KV with Brass bushing Rod, Nuts, Bolts and washers etc inside cable end box |
| 32 | b) One cable box LT Side consisting of 4 numbers porcelain with brass bushing rods complete with nuts and washers suitable for runs of 3.5 Core LT UG Cablesc) Oil Conservator with filter type drain valve and oil level Guaged) Dehydrating breather with fast feel of Dehydrating agente) Explosion Vents |
| 33 | f) thermometer pocket on tank coverg) Rating Plate on terminal marking plateh) Earthing arrangementi) Oil drain filter valvej) Oil Drain Valvek) Lifting Hookl) Oil Conservator with filling hole and capm) Air release valve plugn) Four Plate solid Cast steel detachable rollerso) Earth Bushing for Neutral Outside the cable box for providing independable earthing for neutralp) Suitable size of Channel on foundation for fixing the transformer with joint and stoppperq) PCC Platform complete for transformer |
| 34 | Item No13 : Supply, installation, testing and commissioning of Step downcopper wound transformer of Capacity 160 KVA, outdoor type, PCC Plinth mounted complete with standard fittings and accessories, HT 11 KV 3 Phase, LT 433 volts, 3 Phase 4 wire with off load tappings on HT side to vary secondary voltage within limit, all as per IS:1180-2014, (Level-3) Oil Cooling with fins vector group: DYN 11, incl initial oil fitting complete all as specified incl the following accessories:-a) Three numbers porcelain bushing HT,11KV with Brass bushing Rod, Nuts, Bolts and washers etc inside cable end box |
| 35 | b) One cable box LT Side consisting of 4 numbers porcelain with brass bushing rods complete with nuts and washers suitable for runs of 3.5 Core LT UG Cablesc) Oil Conservator with filter type drain valve and oil level Guaged) Dehydrating breather with fast feel of Dehydrating agente) Explosion Ventsf) thermometer pocket on tank cover |
| 36 | f) thermometer pocket on tank coverg) Rating Plate on terminal marking plateh) Earthing arrangementi) Oil drain filter valvej) Oil Drain Valvek) Lifting Hookl) Oil Conservator with filling hole and capm) Air release valve plugn) Four Plate solid Cast steel detachable rollerso) Earth Bushing for Neutral Outside the cable box for providing independable earthing for neutralp) Suitable size of Channel on foundation for fixing the transformer with joint and stoppperq) PCC Platform complete for transformer |
| 37 | Item No14 : Supply ,fabrication, installation and testing of LT Panel out door type factory made CPRI Approved, water and vermin proof protection ofsuitable size as per IS specificationmade out of 3.15 mm thick outdoor type CRCA sheet dully supported with mild steel angle iron of size 40 x 40 x 5 mm vertical frame and legs with mild steel flat iron 40 x 40 x 5 mm in horizontal sides of the frame with front and back side openable ,single hinged door / shutter with locking arrengement and powder coated finish both internal and external steel surfaces after necessary preparation of steel surfaces including providing PCC (1:3:6) type C2 foundation of suitable size and connections of all outgoing / incommingcableinclusive of necessary excavation and earthwork as required including the following fitment accessories and alsoincluding removing old exisisting one complete all as specified and as directed. Note: Rate of earthwork and PCC work are deemed to be inclusive in this item. |
| 38 | INCOMMING |
| 39 | (a)Copper strip busbar of 800 amps rated capaacity wrapped with PVC sleeves with maintained the colour code and provision of making holes with Copper nuts, bolts & washers for cable connections including hydrograpic insulators with nuts & bolts at both ends= 04 Nos |
| 40 | (b)4 pole MCCB 400 Amps , adjustable thermal magnetic release type 415 Volts,Ics = 100% Icu, breaking capacity 36 KA including all fixing accessories with both ends spreader links - 01 No. |
| 41 | (c)LED Neon indicator lamp (RYB), 230/250 volts, AC -01 set (set of three)Make :- Legrand/L&T/Schneider. |
| 42 | (d)Digital voltmeter of range (0-500) volts, flush mounting type with selector switch – 01 No. |
| 43 | OUTGOING |
| 44 | (a)4 Pole MCCB 250 Amps , adjustable thermal magnetic release type, 4 poles, 415 Volts, Ics = 100% Icu, 36 KA breaking capacity including all fixing accessories with both ends spreader links-02 Nos |
| 45 | (b) 4 Pole MCCB 63 Amps, adjustable thermal magnetic release type, 4 pole, 415 Volts, Ics = 100% Icu, 25 KA breaking capacity including all fixing accessories with both ends spreader links-04 Nos |
| 46 | (c) MCB TPN 32 Amps C series , adjustable thermal magnetic release type, 4 poles, 415 Volts, Ics = 100% Icu, 10 KA breaking capacity including all fixing accessories with both ends spreader links-02 Nos |
| 47 | (d) MCB TPN 20 Amps , 10 KA breaking capacity, C-series including all fixing accessories with lugs-01 No |
| 48 | (e) Multifunctional Digial type timer Switch (Astro type having longitude and latitude of Indian cities memory) 240 volts AC Single Phase - 01 No |
| 49 | (f) Power contractor 4 Pole, 40 Amps,415 Volts, 50 Hz - 01 No |
| 50 | (g)Digital Ammeter of range (0- 250) Amps, flush mounting type with CT’s of ratio 250/5 and selector switch – 08 set. |
| 51 | (h)Enamelled iron danger notice plate of 1.60 mm thick mild steel sheet of size 200 mm X 150mm , white with letters , figures and conventional skull and bones in signal red and fixed with nuts and bolts on door / shutter of JB for LT -01 No. |
| 52 | Item No15 : Supply ,fabrication, installation and testing of LT Panel out door type factory made CPRI Approved, water and vermin proof protection ofsuitable size as per IS specificationmade out of 3.15 mm thick outdoor type CRCA sheet dully supported with mild steel angle iron of size 40 x 40 x 5 mm vertical frame and legs with mild steel flat iron 40 x 40 x 5 mm in horizontal sides of the frame with front and back side openable ,single hinged door / shutter with locking arrengement and powder coated finish both internal and external steel surfaces after necessary preparation of steel surfaces including providing PCC (1:3:6) type C2 foundation of suitable size and connections of all outgoing / incommingcableinclusive of necessary excavation and earthwork as required including the following fitment accessories and alsoincluding removing old exisisting one complete all as specified and as directed. Note: Rate of earthwork and PCC work are deemed to be inclusive in this item. |
| 53 | INCOMMING |
| 54 | (a)Copper strip busbar of 650 amps rated capaacity wrapped with PVC sleeves with maintained the colour code and provision of making holes with Copper nuts, bolts & washers for cable connections including hydrograpic insulators with nuts & bolts at both ends= 04 Nos |
| 55 | (b)4 pole MCCB 315 Amps , adjustable thermal magnetic release type 415 Volts,Ics = 100% Icu, breaking capacity 36 KA including all fixing accessories with both ends spreader links - 01 No. |
| 56 | (c)LED Neon indicator lamp (RYB), 230/250 volts, AC -01 set (set of three)Make :- Legrand/L&T/Schneider. |
| 57 | (d)Digital voltmeter of range (0-500) volts, flush mounting type with selector switch – 01 No. |
| 58 | OUTGOING |
| 59 | (a)4 Pole MCCB 200 Amps , adjustable thermal magnetic release type, 4 poles, 415 Volts, Ics = 100% Icu, 36 KA breaking capacity including all fixing accessories with both ends spreader links-02 Nos |
| 60 | (b) 4 Pole MCCB 63 Amps, adjustable thermal magnetic release type, 4 pole, 415 Volts, Ics = 100% Icu, 25 KA breaking capacity including all fixing accessories with both ends spreader links-04 Nos |
| 61 | (c) MCB TPN 32 Amps C series , adjustable thermal magnetic release type, 4 poles, 415 Volts, Ics = 100% Icu, 10 KA breaking capacity including all fixing accessories with both ends spreader links-02 Nos |
| 62 | (d) MCB TPN 20 Amps , 10 KA breaking capacity, C-series including all fixing accessories with lugs-01 No |
| 63 | (e) Multifunctional Digial type timer Switch (Astro type having longitude and latitude of Indian cities memory) 240 volts AC Single Phase - 01 No |
| 64 | (f) Power contractor 4 Pole, 40 Amps,415 Volts, 50 Hz - 01 No |
| 65 | (g)Digital Ammeter of range (0- 200) Amps, flush mounting type with CT’s of ratio 250/5 and selector switch – 08 set. |
| 66 | (h)Enamelled iron danger notice plate of 1.60 mm thick mild steel sheet of size 200 mm X 150mm , white with letters , figures and conventional skull and bones in signal red and fixed with nuts and bolts on door / shutter of JB for LT -01 No. |
| 67 | Item No16 : Supply ,fabrication, installation and testing of LT Panel indoor type factory made CPRI Approved, water and vermin proof protection ofsuitable size as per IS specificationmade out of 2.00 mm thick type CRCA sheet dully supported with mild steel angle iron of size 40 x 40 x 5 mm vertical frame and legs with mild steel flat iron 40 x 40 x 5 mm in horizontal sides of the frame with front and back side openable ,single hinged door / shutter with locking arrengement and powder coated finish both internal and external steel surfaces after necessary preparation of steel surfaces including providing PCC (1:3:6) type C2 foundation of suitable size and connections of all outgoing / incommingcableinclusive of necessary excavation and earthwork as required including the following fitment accessories and alsoincluding removing old exisisting one complete all as specified and as directed. Note: Rate of earthwork and PCC work are deemed to be inclusive in this item. |
| 68 | INCOMMING |
| 69 | (a)Copper strip busbar of 400 amps rated capaacity wrapped with PVC sleeves with maintained the colour code and provision of making holes with Copper nuts, bolts & washers for cable connections including hydrograpic insulators with nuts & bolts at both ends= 04 Nos |
| 70 | (b)4 pole MCCB 200 Amps , adjustable thermal magnetic release type 415 Volts,Ics = 100% Icu, breaking capacity 36 KA including all fixing accessories with both ends spreader links - 01 No. |
| 71 | (c)LED Neon indicator lamp (RYB), 230/250 volts, AC -01 set (set of three)Make :- Legrand/L&T/Schneider. |
| 72 | (d)Digital voltmeter of range (0-500) volts, flush mounting type with selector switch – 01 No. |
| 73 | OUTGOING |
| 74 | (a) 4 Pole MCCB 63 Amps, adjustable thermal magnetic release type, 4 pole, 415 Volts, Ics = 100% Icu, 25 KA breaking capacity including all fixing accessories with both ends spreader links-07 Nos |
| 75 | (b)Digital Ammeter of range (0- 100) Amps, flush mounting type with CT’s of ratio 250/5 and selector switch – 07 set. |
| 76 | (c)Enamelled iron danger notice plate of 1.60 mm thick mild steel sheet of size 200 mm X 150mm , white with letters , figures and conventional skull and bones in signal red and fixed with nuts and bolts on door / shutter of JB for LT -01 No. |
| 77 | Item No17 : Supply ,fabrication, installation and testing of LT Panel indoor type factory made CPRI Approved, water and vermin proof protection ofsuitable size as per IS specificationmade out of 2.00 mm thick type CRCA sheet dully supported with mild steel angle iron of size 40 x 40 x 5 mm vertical frame and legs with mild steel flat iron 40 x 40 x 5 mm in horizontal sides of the frame with front and back side openable ,single hinged door / shutter with locking arrengement and powder coated finish both internal and external steel surfaces after necessary preparation of steel surfaces including providing PCC (1:3:6) type C2 foundation of suitable size and connections of all outgoing / incommingcableinclusive of necessary excavation and earthwork as required including the following fitment accessories and alsoincluding removing old exisisting one complete all as specified and as directed. Note: Rate of earthwork and PCC work are deemed to be inclusive in this item. |
| 78 | INCOMMING |
| 79 | (a)Copper strip busbar of 250 amps rated capaacity wrapped with PVC sleeves with maintained the colour code and provision of making holes with Copper nuts, bolts & washers for cable connections including hydrograpic insulators with nuts & bolts at both ends= 04 Nos |
| 80 | (b)4 pole MCCB 125 Amps , adjustable thermal magnetic release type 415 Volts,Ics = 100% Icu, breaking capacity 36 KA including all fixing accessories with both ends spreader links - 01 No. |
| 81 | (c)LED Neon indicator lamp (RYB), 230/250 volts, AC -01 set (set of three)Make :- Legrand/L&T/Schneider. |
| 82 | (d)Digital voltmeter of range (0-500) volts, flush mounting type with selector switch – 01 No. |
| 83 | OUTGOING |
| 84 | (a) MCB TPN 32 Amps C series , adjustable thermal magnetic release type, 4 poles, 415 Volts, Ics = 100% Icu, 10 KA breaking capacity including all fixing accessories with both ends spreader links-05 Nos |
| 85 | (b) MCB TPN 20 Amps , 10 KA breaking capacity, C-series including all fixing accessories with lugs-01 No |
| 86 | (c) Multifunctional Digial type timer Switch (Astro type having longitude and latitude of Indian cities memory) 240 volts AC Single Phase - 01 No |
| 87 | (d) Power contractor 4 Pole, 40 Amps,415 Volts, 50 Hz - 01 No |
| 88 | (e)Digital Ammeter of range (0- 200) Amps, flush mounting type with CT’s of ratio 100/5A and selector switch – 05 set. |
| 89 | (f)Enamelled iron danger notice plate of 1.60 mm thick mild steel sheet of size 200 mm X 150mm , white with letters , figures and conventional skull and bones in signal red and fixed with nuts and bolts on door / shutter of JB for LT -01 No. |
| 90 | Item No15 : M & L for horizontal boring mechanically across the existing road without disturbing the road surface for inserting 80/40 mm bore GI pipe all complete all as specified and as directed by EIC. ( Note :- GI pipe will be measured and paid respective item of sch\"A\"). |
| 91 | Item No18 : Supply and fixing of automatic street light switch using infrared sensor based nature switch for automatic switching of street lights.Nature switch operation should bebased on natural light lux level. Required illuminance level for switching on is < 30 Lux and for switching off >10 lux. The sensor should also have part night operation facility of min 4 hrs to max 12 hrs.The sensor along with suitable power contactors incoming outgoing MCBS SP andand automanual (sensor bypass selection option should be enclosed in a pole /wall mountable enclosure made of rust proof electric shock proof termite proof and FR grade SMC Box conforming to IP54 single phase load of 8 KW with circuit wiringmin 10 sq mm copper wire 63 Ampscontactorans suitable MCBs atboth positions at incoming and out goings of breaking capacity 10 KA complete including necessary clamp (2 sets) / anchor bolt(4 nos)for fixing on pole / walllcomplete all as directed |
| 92 | Item No19 : S&F in replacement hot press moulded SMC junction/terminal box of size with internal diamensions of 200 x 140 x 95 mm with hinged door, incl provision of 2 way connector 415 Volts made out of polycarbonate or bakelite and 1 No MCB of 6 Amps with DIN bar, drilling holes for cable connections, connecting incoming and or out going cables by providing suitable of size of cable lugs/glands, fixed on pole by means of clamps made out of MS flat iron of size 25mm x 3 mm 2 Setincluding dismantling of old unserviceable all as specified and as directed. |
| 93 | Item No20 : Earthing complete with galvanised steel earth plate electrode 60cm×60cm.× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less\"than 1.5 metres below normal ground level, connected to using galvanised iron strip 32×6mm as earthing lead by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 connected to earthing test point all as specified or indicated including testing on completion |
| 94 | Item No21 : Earthing complete with copper plate 60×60cm ×3.15mm thick electrode, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less\"than 1.5 metres below normal ground level, connected to 20×3mm copper strip by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 connected to earthing test point all as specified or indicated including testing on completion |
| 95 | Item No22 : Earthing complete with galvanised steel earth plate electrode 60×60cm.× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less\"than 1.5 metres below normal ground level, connected to galvanised earth lead wire 4.0mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 connected to earthing test point all as specified or indicated including testing on completion |
| 96 | External Water Supply |
| 97 | Item No23: Supply, installation, commissioning and testing of Pumping sets, centrifugal, electric driven, complete 7.5 BHP(5.0 WHP) inclusive of starter and PCC foundation- 04 Nos Qty[2 Nos running + 2 Nos stand by] (Total 7.5HP X 04). |
| 98 | Item No24 : Supply and lay pipe ductile Iron , S/S including specials, Class “K-9” ,100 mm (4”) dia complete all as specified and as directed. |
| 99 | Item No25 : M & L for Construction of brick masonryvalves pits, of the following internal dimension complete with 3.15 mm thick MS sheet cover angle iron frame duly painted with locking arrangement including all necessary excavation and earth work PCC work complete. |
| 100 | (a) 900 mm x 900 mm x 900 mm |
| 101 | Item No26 : Cutting the existingBT road / CONCRETE ROAD of civil authorities ( Cantt Board/pwd or any other department )after obtaining permission from appropriate authoritiespreferabely in night times including necessary lighting arrangementby using mechanical means l, depth and width not less than 75 cmfor laying of 300mm diaMS pipeand filling back with excavated soil up to 60 %road portion and 40 % shall be made with cement concrete 1:2:4 type B1 (using 20 mm graded stone aggregate incase of concrete road and Bituminious top in case of BT Roadcomplete all as specified and directed. |
| 102 | (a) The contractor is responsible for obtaining the approval from Police Department for Traffic Diversion and related works if required in consultation with the MES deparatment if required.(b) Contractor is responsible for repair/replacement of any damages to the existing structures, Under Ground HT/LT/OFC Cables etc during the course of execution. |
| 103 | (c)CIVIL ROAD CROSSING TO BE DONE AT2 PLACESS. NECESSARY PERMISSION FOR CROSSING ROAD /LAYING OF PIPEFROM CANTT BOARD/ ANY OTHER CIVIL DEPARTMENT INCLUDING NECESSARY FEE IF ANY APPLICABLE IS THE RESPONSIBILITY OF THE CONTRACTOR. NO CLAIM IN THIS REGARD WILL BE ENTARTAINED DURING EXECUTION STAGE. DEPARTMENT ONLY ASSIST FOR OBTAINING APPROVAL. Quoted rates inclusive of all arrangement required for the above |
| 104 | Item No27 : Supplying, laying, jointing and testing of 300 mm nominal bore ERW (Electric Resistance Welded) Mild Steel (MS) Pipe, conforming to IS:3589 (Grade Fe 410), having minimum wall thickness of 6 mm, with beveled ends suitable for welding, including factory-applied internal cement mortar lining (as per IS:3589/IS:781), external protective coating with 3-layer polyethylene (3LPE) or coal tar enamel with wrapping, lowering into trench, aligning, welding with proper electrodes, testing the joints hydraulically, including all labour, tools & plant, but excluding specials, valves, and thrust blocks, complete as per specifications and direction. |
| 105 | Item No28 :Supplying, laying, jointing and testing of 100 mm nominal bore ERW (Electric Resistance Welded) Mild Steel (MS) Pipe, conforming to IS:3589 (Grade Fe 410), having minimum wall thickness of 5 mm, with beveled ends suitable for welding, including factory-applied internal cement mortar lining (as per IS:3589/IS:781), external protective coating with 3-layer polyethylene (3LPE) or coal tar enamel with wrapping, lowering into trench, aligning, welding with proper electrodes, testing the joints hydraulically, including all labour, tools & plant, but excluding specials, valves, and thrust blocks, complete as per specifications and direction. |
| 106 | Fire Fighting System |
| 107 | Item No29 : Supply only of fire extinguiser ISI marked CO2 type Fire Extinguisher 4.5 KG capacity conforming to IS : 15683 :2006 (old IS : 2878) made from seamless cylinder conforming to IS : 7285 duly approved by chief controller of explosive , Nagpur fitted with ISI Marked Controlled valve conforming to IS : 3224 , high pressure 1 mtr long discharge hose and horn complete with initial gas charged with carrying handle and wall mounting bracket, , suitable for operating between 30 degree centrigrade to + 55 degree centigrate, Fire Rating Class - 138. |
| 108 | Item No30 : Supply only of stored pressure fire extinguiser ISI marked powder type Fire Extinguisher 6 KG capacity suitable for Class \"A\", \"B\", \"C\" Fire consisting with discharge hose and nozzle of welded cylinder, squeeze lever discharge valve fitted with pressure indicating guage, internal discharge tube, discharge nozzle suspension bracket conforming to IS : 15683 :2006 (old IS : 2878) duly charged with ISI Marked Mono Ammoniumphosphate base ABC powder conforming to IS : 14609 and pressurized with Nitrogen Gas, suitable for operating between 30 degree centrigrade to + 55 degree centigrate, Fire Rating Class - 1A & 13B |
| 109 | Item No31 : Supply only of Fire bucket iron body red colour 10 L capacity for dry sand stored type ISI MarkedIS : 2546 :2006, complete all as specified and as directed. |
| 110 | Item No32 : Supply only of Fire Extinguisher Mechanical Foam type ISI Marked Foam (AFFF) type Fire Extinguisher 9 ltrs capacity fitted with Forged Brass squeeze lever discharge valve, conforming to IS : 15683 :2006, complete with initial refill consisting of ISI Marked CO gas cartridge of 60 gms capacity conforming to IS 4947 and ISI Marked AFFF conforming to IS : 4989, suitable for operating between + 50 degree centrigrade , Fire Rating Class - 3A & 34B |
| 111 | TV connection & conduit for Telephone connection |
| 112 | Item No33 : M & L TV socket outlet suitable for co-axial cable one module complete all as specified and as directed. |
| 113 | Item No34 : M & L cable TV splitter 4 way O/G with 1- way I/C complete including mounting inside PVC box of suitable size flushed to wall complete all as specified and as directed. |
| 114 | Item No35 : M & L coaxial cables with electrolytic grade solid bare copper conductor, gas injected physical polythylene foam insulation, with laminated aluminium tape and AI wire braid, jelly flooded and PVC jacketing in Black colour drawn in conduit and connecting and testing complete for type RG-59 cable. Note : PVC conduit and accessories shall be measured and paid separetly. |
| 115 | Lightning Protection & Aviation Light |
| 116 | Item No36 : M & Lfor Earth continuity conductor or main earthing lead of 32 x 6 mm copper strip, buried in ground or fixed to wallcomplete all as specified and as directed . |
| 117 | Item No37 : Supply and installation of Aviation light Red colours, die cast aluminium with PC cover, IP 66 protection compleate all as specified and as directed. |
| 118 | Hot Water Supply |
| 119 | Item No38 : Supply and fix electric water heater, storage type steel body with copper inner tank and heating element upto 2 KW capacity 25 litre, BEE 5 Star rated complete with all accessories such as safety valve, thermostate, NRV, connection piece complete all as specified and directed. |
| 120 | Road Path Culvert |
| 121 | Item No39 : Provn of hume pipe culvert with & using Hume pipe 450 dia class NP-3 and 6 mtr long laid over concrete bed and Job jointed with copping & rendering complete all as spd. |
| 122 | UG Sump |
| 123 | Item No40 : Designing (hydraulically, structurally and aesthetically), and constructing RCC sumps in M-30 mixof average flow of 300 Cum per day including excavation in all types of strata, foundation concrete, containerwalls, bottom slab, top RCC roof slab with CI manhole covers and with plaster and water proofingas per zonal specification including epoxy paint inside, refilling of earth and disposal of surplusearth within 50 m lead, including all piping connections, valves, internal electrification, MS ladder,ventilation shaft, BB chambers with 5m of outer wall of tank complete including test for watertightness and hydraulic functioning. Top room as per zonal specifications included. ( Size 2.5m dia and 8 mtr depth) |
| 124 | Demolition |
| 125 | Item No41 : Taking down carefully main switches DB’s/ MCBDB’s with MCB including sub main wiring complete on as specified and directed |
| 126 | Item No42 : Second down streetlight pole including street light any capacity including all fittings and two store for keeping in safe custody or for taking credit complete or specified and directed |
| 127 | Item No43 : Taking down indoor / outdoor LT type feeder panel any sizes including all fittings and to store for keeping in safe custody or for reuse and fix in other location complete all specified and directed |
| 128 | Item No44 : Taking out old unserviceable LT cables of cross sectional area any size including excavation, returning filling, pipes bricks or pre cast concrete cable cover etc of any description from trenches walls poles pi disconnecting the cable from pole feeder panel bolt ETC and keep serviceable bricks or precast concrete cover cable pipe ETC to store for keeping in safe custody or for taking credit complete all specified and directed |
| 129 | Item No45 : Taking up or down CIGIDI water tubing any size and connecting items including wall any size complete or specified and directed |
| 130 | Item No46 : Take him down see Fen Efen Wall mounted fin geezer any size including connecting materials complete all specified and directed. Note removing materials sell be handover to mes store for future disposal action |
| 131 | SCHEDULE \"A\"(Schedule of credit)Schedule of Credit Rs 1698149.00 (Minus) inserted by the MES. (Note : Credit amount shall be deducted manually to arrive net bid amount) |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
| 5 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail