| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 20-02-2026 | Revised Tender Pages | Other | 04-03-2026 |
| 2 | 20-02-2026 | Revised BOQ | BOQ | 04-03-2026 |
| Sl. No. | Item Description |
| 1 | B & R Division Items |
| 2 | Demolition of un-reinforced cement concrete in ground floor and paving not exceeding 15 cm thick (below or above ground level) complete all as specified and directed. |
| 3 | Demolition of Concrete of any description andin any position not otherwise specifically provided complete all as specified and directed. |
| 4 | Demolition of reinforced cement concrete in roofs, floors (other than ground floors), beams, staircases, landing, chajjas and similarsuspended work complete all as specified and directed. |
| 5 | Demolition of brick work or stone/ boulder masonry, built in cement mortar including all quoins, pillars etc. complete all as specified and as directed. |
| 6 | Dismantling floor, hearth or wall tilling including cement mortar bedding (but not backing) removing serviceable tiles to stores and rubbish off the premises. |
| 7 | Dismantling stone slabs of any description or thickness in floors, aprons etc. laid, bedded and pointed in any mortar and disposing off complete all as specified and as directed |
| 8 | Demolition of reed lathing, single or double including battens and plaster or chiken wire lathing all as specified. |
| 9 | Dismantling mild steel work or wrought iron of any description and in any position complete all as specified and as directed. |
| 10 | Dismantling plain or corrugated steel sheeting, any gauge or any thickness as in roof covering, wall cladding, etc.including all necessary staging / scaffolding, etc. as required complete all as specified and as directed. |
| 11 | Dismantling of timber scantling 40 Sqcm and over in section, in any position in unframed work complete all as specified and directed. |
| 12 | Dismantling wall and ceilingboards (fibre, pulb, insulation etc) or insulation boards slabs/blankets any thickness including cover fillets all as specified and as directed. |
| 13 | Dismantling boarding any description fixed in any position with nails all as specified. |
| 14 | Dismantling asbestos cement/PVC pipe 50/75/100 mm dia including clamps complete all as specified and directed. |
| 15 | Taking down cement plaster on brick or stone walls etc, including raking out joints, hacking for key scrubing down with water etc complete all as specified and as directed. |
| 16 | Taking down chowkhats or frame with shutters (without taking off shutters from frame) each not exceeding 1.50 Sqm each complete all as specified. |
| 17 | Taking down Chowkats or frames with shutters exceeding 1.5 Sqm but not exceeding 4 Sqm each (without taking off shutters from the frame) complete all as specified. |
| 18 | Taking up or down 15mm diaGI steel tubing and connections, including cleaning for refixing or removal to store complete all as specified and as directed. |
| 19 | Taking up or down 20mm diaGI steel tubing and connections, including cleaning for refixing or removal to store complete all as specified and as directed. |
| 20 | Surface dressing n exc 15 cm deep and gettingout in soft / lose soil complete all as specified |
| 21 | Excavating in trenches, n exc 1.50 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out soft/ loosetype of soil complete all as specified and directed. |
| 22 | Returning, filling in trenches including spreading, leveling watering and ramming in layers not exceeding 25cm all as specified. |
| 23 | Removing of surplus soil not exceeding 50 m and deposited where directed at a level not exceeding 1.50m above the starting point all as specified. |
| 24 | Excavating in post holes each n exc 0.5 cum, getting out, in soft /loose soil, ramming earth filling or borken rubble mixed with earth around in layers nexc 25 cm watering and removing ssurfaces soil to distance nexc 50 m and making good surfaces all as specified and directed. |
| 25 | M&L for earth filling under floor incl spreading ,levelling & well ramming includuing watering as required n exc . 25 cm thick . (Note :- Earthobtained from relevant items mentioned above is reused ) |
| 26 | M&L for Treating the backfill in contact with foundation at the rate of 7.5 litres of emulsion per square metre of vertical surface (Area of the sub structure in contact with backfill to be measured) complete all as specified. |
| 27 | M&L for Treating the top surface of filled earth at the rate of 5 litres of emulsion per square metre of surfacecomplete all as specified. |
| 28 | M&L for Treating the soil under plinth protection at the rate of 5 litres of emulsion per square metre of surface area complete all as specified. |
| 29 | M&L for Treating the soil along with external perimeter of building at the rate of 2.25 litre of emulsion per metre of the perimeter wall complete all as specified. |
| 30 | M&L for Hardcore broken stone of gauge n exc 63mm deposited spread and levelled in layers n exc 15cm thick watered and rammed to a true surface complete all as specified and directed. |
| 31 | M&L for PCC (1:4:8), Type D-2 using 40 mm graded stoneaggregate as in foundations, sub-base,filling and mass concrete complete all as specified. |
| 32 | M&Lfor providing 100 mm thick plain cement concrete (1:4:8) type D-2 using (40mm gradedstone aggregate) as in Sub base of floor rough surface complete all as specified. |
| 33 | M&Lfor providing 75 mm thick plain cement concrete (1:4:8) type D-2 using (40mm gradedstone aggregate) as in Sub base of floor rough surface for receiving tile complete all as specified. |
| 34 | M & Lfor Plain Cement Concrete(1:3:6) type C-1 using 20mm graded stoneaggregate as in surface channel and drainall as specified and directed. |
| 35 | Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred/stopped ends foretccomplete all as specified and directed. |
| 36 | Add or deduct for each 25 mm girth or part thereof over or under 30cm(For adjustment in girth of item mention above) |
| 37 | M & Lfor 75mm thick plain cement concrete 1:3:6 type C-2 (using 40mm graded stone aggregate) as in plinth protection finished even and fair without using extra cement laid inpanels and joints filled with bituminous mastic filling with 1 part of bitumen and 3 part of sand complete all as specified and directed. |
| 38 | M & Lfor 75mm thickplain cement concrete 1:3:6 type C-1 (using 20mm graded stone aggregate) as in plinth protection finished even and fair without using extra cement laid inpanels and joints filled with bituminous mastic filling with 1 part of bitumen and 3 part of sand complete all as specified and directed. |
| 39 | M & L for plain cement concrete (1:2:4) type B-1 using 20mm graded aggreagate as in bed blocks, coping , cills, steps, kneelers, bed plates, apex stones kerbs and similar works including necessary formwork complete all as specified and directed. |
| 40 | Material and labour for 50 mm thick Plain Cement concrete type B-2 1:2:4 (40mm graded crushed stone aggregates) for sub base in floor fair and rough for receiving tiles, topping layer all as specified and directed. |
| 41 | Use and waste formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter rough finished flat surfaces of concrete complete all as specified and as directed. |
| 42 | Use and waste formwork to sides and soffits of floor or roof beam, beam hunching, girder, lintels, cantilever, shelves including supports etc for rough finished flat surfaces of concrete complete all as specified and directed |
| 43 | Use and waste of formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping) complete all as specified and directed |
| 44 | Use and waste of formwork to sides of pillars, posts, struts, piers, columns and stanchions for rough finished flat surfaces of concreteall as specified and directed. |
| 45 | Use and waste of formwork to edges of concrete flats, breaks in floors, openings in concrete walls, floors and roofs and sides of RCC/PCC bands in walls, horizontal or sloping, and similar work all exceeding 20cm wide. (Where RCC/PCC band in walls, spanning and opening, the formwork soffit complete all as specified and directed |
| 46 | Use and waste formwork to edges of concrete flats,slabs etc incl fair finished surfaces exe 5cm but n.exe 10cm wide all as specified nd directed. |
| 47 | Material and labour for providing Reinforced Cement Concrete M-25 (Design Mix) using 20 mm graded aggregate as in foundation including rafts, footings, foundation beams, plinth beams, bases for columns etc complete all as specified and directed. |
| 48 | Material and labour for providing Reinforced Cement Concrete M-25 (Design Mix) using 20 mm graded aggregate as in columns, pillars, piers, posts and struts complete all as specified and directed. |
| 49 | Material and labour for providing Reinforced Cement Concrete M-25 (Design Mix) using 20 mm graded aggregate as in beams, cantilever, lintels over 1.5 m complete all as specified and directed. |
| 50 | Material and labour for providing Reinforced Cement ConcreteM-25 (Design Mix) using 20mm aggregate as in slab supported on walls , beams, and column in floors, roof, landing, balconies, canopies, deck slab and in shelves and like etc comlpete all as specified and directed. |
| 51 | Material and labour for providing Reinforced Cement Concrete M-20 (Nominal Mix) 1:1.5:3 type A1 using 20 mm graded aggregate as in beams, cantilever, lintels over 1.5 m complete all as specified and directed. |
| 52 | Material and labour for providing Reinforced Cement Concrete M-20 (Nominal Mix)1:1.5:3 type A1using 20 mm graded aggregate as in columns, pillars, piers, posts and struts complete all as specified and directed. |
| 53 | Material and labour for providing Reinforced Cement ConcreteM-20 (Nominal Mix) 1:1.5:3 type A1using 20mm aggregate as in slab supported on walls , beams, and column in floors, roof, landing, balconies, canopies, deck slab and in shelves and like etc comlpete all as specified and directed. |
| 54 | M & Lfor 10mm dia and over TMT bars, cut to length bend to shape as required including cranking, hooking etc and binding with and including mild steel wire (annealed) not less than 0.9 mm dia complete all as specified and directed. |
| 55 | M & Lfor 6mm to 8mm dia and over TMT bars, cut to length bend to shape as required including cranking, hooking etc and binding with and including mild steel wire (annealed) not less than 0.9 mm dia complete all as specified and directed. |
| 56 | M & Lfor Mild Steel TMT Bar 6mm dia and over up to 10 mm dia as in stirrups, spacers and binders as required including cranking, hooking etc and binding with and including mild steel wire (annealed) not less than 0.9 mm dia complete all as specified and directed |
| 57 | M & L for brickwork with subclass \"B\" or locally available best qualityold size bricks, straight or curved on plan exc 6 m mean raduis,built in CM (1:6) complete all as specified and directed. |
| 58 | M & L for half brick work in cement mortar (1:4) straight or curved on plan to any radius with locally available Subclass ‘B’ old size best quality bricks all as specified . |
| 59 | M & Lrendering 10mm thick cement plaster on other than fair faces of brick wall or condrete surfaces in CM (1:6) finished even and smooth without using extra cement complete all as specified. |
| 60 | M & Lrendering 10mm thick cement plaster on other than fair faces of brick wall or condrete surfaces in CM (1:6) finished fair and even complete all as specified. |
| 61 | M & Lrendering 15 mm thick cement plaster in two layer each of 10+5 mm thick on fair faces of brick wall or concrete surfaces in CM (1:4) & water proofing compound mixed with second layer @ 3% finished fair and even complete all as specified. (Note :WPC measured separately). |
| 62 | M & Lrendering 15 mm thick cement plaster in two layer each of 10+5 mm thick on fair faces of brick wall or concrete surfaces in CM (1:4) & water proofing compound mixed with second layer @ 3% finished even and smooth without using extra cement complete all as specified. (Note :WPC measured separately). |
| 63 | M & Lrendering 15 mm thick cement plaster in two layer each of 10+5 mm thick on other than fair faces of brick wall or concrete surfaces in CM (1:4) & water proofing compound mixed with second layer @ 3% finished even and smooth without using extra cement complete all as specified. (Note :WPC measured separately). |
| 64 | Supply only integral water proofing compound WPC complete all as specified. |
| 65 | M & L Non Skid ceramic paver tiles colour 7 to 8mm thick (square/ rectangular) area of each tile exceeding 0.06 but not exceeding 0.11 sqm, as in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tile including 20 mm thick screed bed or bedding layers in cement mortar 1:6 over brushing with neat cement slurry as specified |
| 66 | M & L Non Skid ceramic tiles colour 7 to 8mm thick (square/ rectangular) area of each tile exceeding 0.11 but not exceeding 0.18 sqm, as in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tile including 15 mm thick screed bed or bedding layers in cement mortar 1:6 over brushing with neat cement slurry as specified |
| 67 | M & L Non Skid ceramic tiles colour 7 to 8mm thick (square/ rectangular) area of each tile exceeding 0.18 but not exceeding 0.38 sqm, as in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tile including 15 mm thick screed bed or bedding layers in cement mortar 1:6 over brushing with neat cement slurry as specified |
| 68 | Material and labour Non-skid coloured ceramic tiles 7 to 8 mm thick ( square/rectangular) area of each tiles exc 0.18 sqm but not exc 0.38 sqm as in vertical surfaces of skirting/bdado etc over 10 mm thick rendering in cm (1:4) as backing coat complete all as specified. |
| 69 | M & LGlazed ceramic coloured tilesin vertical surface size 450mm x 350mm x & ( 6mm to 7mm )mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match over & including10mm thick screed bed or backing coat in cement mortar 1:4layingof skirting/dado on walls all as specified and directed. |
| 70 | M&L Machine cut kota stone slab flooring 20-25mm thick over cement screed base laid over 20mm thick screed bed in cm 1 : 3 with cement slurry @ 4 kg/sqm jointed and pointed with grey cement slurry mixed with pigment to match the shade of slab including cutting and polishing to achieve mirror/granite finish complete all as specified and as directed. |
| 71 | M&L in repairs for 18-20mm thick granite stone slab, of any type, table rubbed and polished, in steps, jambs, pillars, window cills, cooking platforms and the like in laid over and including 15mm thick screed in cement mortar (1:4) (rate shall be included) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of slab and taking off old damaged slab and disposing off complete all as specified and as directed. |
| 72 | Supply and fix pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws as specified. |
| 73 | Supply and fix pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws as specified. |
| 74 | Supply and fix Framed work such as grills, gratings, etc.. with ends of bars or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165 complete all as specified and directed. |
| 75 | S&F Roof trusses (framed), trussed,purlins, crane gantries, rails ,posts and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats nuts bolts plates (plain or chequered) etc. |
| 76 | S&F of mild steel rolled sections (Fe-290, Gde E-165) as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and other misc brackets; fixed with angle cleats for fixing of eaves board or other connecting plates complete all as specified. |
| 77 | S & F Pressed steel frames made of 1.25mm thick MS sheet of profile 105X60mm for door and window frames with one or more rebates includinghinges (100/50mm stainless steel),lock strike plate, shock absorber, 20mm dia 60mm long MS conduit for housing of a drop bolt, treating of internal surfaces of chowkhats with coal tar or black paint including hinges, hold fasts/lugs etc complete all as specified. |
| 78 | S & F Pressed steel frames made of 1.25mm thick MS sheet of profile 125X60mm for door and window frames with one or more rebates includinghinges, lock strike plate, shock absorber, treating of internal surfaces of chowkhats with coal tar or black paint including hinges, hold fasts/lugs etc complete all as specified. |
| 79 | M & L Plain Cement concrete (1:3:6), type C-0 using 12.5mm graded stone aggregate as in filling of steel chowkhatsand concrete for fixing of holdfast including necessary form work complete all as specified. |
| 80 | S & F 30 mm thick Flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides , smooth finish with lipping of teak wood on edges all as specified and directed. |
| 81 | S&F 2nd class hard wood, 35 mm thick, plain framed panel shutter (any numbers of panel) with panels of timber flat on both sides (feather edged) or 12 mm thick veneered particle board medium density fitted to chowkats or frames complete all as specified and directed. |
| 82 | S&F 2nd class hard woodglazed andskeleton door shutters 35 mm thick open rebated and prepared to receive glass, guage etc (withoput sash bars), edge of framing plain chemfered ro rounded fitted with cut and mitred beds for securing glass etc size of members of shutter as specified in SSR Part I section 8 clause 8.20(a) complete all as specified and directed. |
| 83 | S&F Powder coated aluminium (minimum thickness of powder coating 50 micron) for shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber/neoprene gasket required (Fittings shall be paid for separately) with extruded built up standard tubular sections/ appropriate Z-sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ paneling, C.P. brass/ stainless steel screws all complete as per architectural drawings and the directions of Engineer-in-charge |
| 84 | Supply and fixStainless steel wire cloth. 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples complete all as specified. |
| 85 | S&F 3.00 mm thick sheet glass ordinary quality and glazing with oil putting square nexc 0.5 sqm in each pane complete all as specified. |
| 86 | S&F 4.00 mm thick sheet glass ordinary quality and glazing with oil putting square exc 0.5 sqm in each pane complete all as specified. |
| 87 | S&F PVC roller in Aluminium body of suitable size for sliding shutters complete all as specified. |
| 88 | S&F side locks of Aluminium body, suitable size for sliding shutters complete all as specified. |
| 89 | S&F 100mm long stainless steel butt hinges of selected quality complete all as specified. |
| 90 | S&F 100mm MS Butt hinges, medium weight, cold rolledcomplete all as specified. |
| 91 | S&F Mortice lock, vertical type size 100mm, of brass 04 levers vertical type complete all as specified. |
| 92 | M & L for 12 mm thick Prelaminated particle board,Exterior grade, prelaminated on bothside with decorative choice lamination & otherside balancing white lamination, all as directed. |
| 93 | Supply and fix 300mm long Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixedcomplete all as specified. |
| 94 | Supply and fix 150 mm long aluminium handles cast type anodised complete all as specified & directed . |
| 95 | Supply and fix 150 mm long aluminum anodised barrel tower bolts of extruded section complete all as specified and directed. |
| 96 | S&F double action spring hinges, mild steel with steel wire spring, stove enamelled, black, size of spring hinge 150mm complete all as specified and as directed. |
| 97 | S&F as in repairs 25 mm dia and 1mm thick MS chromium platedcurtain rods with fixing side fancy type brackets end knobs fixed with steel screws etc all as specified and directed . |
| 98 | Supply and fix in repair vitreous china wash basin, white, under counter, size 565 X 465 X 185 mm oval shape including waste coupling and excluding taps, waste ,chain and plug and porcelain stoppercomplete all as specified. Make:Parryware Catalouge No- C0483 and Equivalent as per approved list of make) |
| 99 | Supply and fixvitreous china wash basin, white, counter top, size 560mm X 461mm oval shape including waste coupling but excluding taps, waste chain, and plug and porcelain stopper complete all as specified. Make:Hindware Catalouge No-10017 and equivalent as per approved list of make. |
| 100 | S&F of Corner /glass shelf complete all as specified and directed. |
| 101 | S & Fas in repair soap dish chromium plated complete all as specified. |
| 102 | S & F in repair PVC connections 15 mm size with PTMT nuts of length 450 m complete all as specified. |
| 103 | S & F PVC connections 15 mm size with PTMT nuts of length 450 m complete all as specified. |
| 104 | S & F as in repair 15mm bore pillar tap cast copper alloy with capstan head, chromium plated concealed screwed down high pressure with or without hot or cold with long shunk screwed shanks and fly nuts screwed for iron pipes and connecting to water pipe line complete all specified and directed. |
| 105 | S & F 15mm bore pillar tap cast copper alloy with capstan head, chromium plated concealed screwed down high pressure with or without hot or cold with long shunk screwed shanks and fly nuts screwed for iron pipes and connecting to water pipe line complete all specified and directed. |
| 106 | Supply and fix 15 mm bore bib taps fancy type, chromium plated, castcopper alloy with crutch or butter fly handle, screwed down, screwed for iron pipe or for brass ferrule all as specified. |
| 107 | Supply and fix 15mm bore stop valve/angle valve, cast copper alloy cromium plated fancy type screwed down high pressure, with crutch or butterfly handle for 15 mm bore pipe or for unions all as specified. |
| 108 | S & F as in repair bevelled edge mirror 6mm thickness complete all as specified and directed.Make : Modiguard, Saint Gobain or equivalent |
| 109 | S&F in repairs full sized (as approved) bevelled edge mirror of selected quality glass mounted on 9mm thick commercial plywood with PVC moulding frame all round, fancy type and fixed to wooden plugs with chromium plated brass screws and cup washers complete all as specified and as directed |
| 110 | Supply and fix as in repair Towel rail, 20mm dia brass chromium plated, 600mm long with fancy type brass chromium plated brackets on both sides and fixed with steel screws and wooden/rawl plugs as in repair complete all as specified. |
| 111 | Supply and fix Towel rail, 20mm dia brass chromium plated, 600mm long with fancy type brass chromium plated brackets on both sides and fixed with steel screws and wooden/rawl plugs as in repair complete all as specified. |
| 112 | Supply and fix stainless steel sink, 1.00mm thick for kitchen or laboratory, with plug, waste pipe, washers, including cantilever cast iron brackets, connecting union etc.,overall size 495mm x 420 mm with bowl size 410mm x 330mm x 160mm etc complete all as specified and as directed. |
| 113 | Supply and fix asin repairs, 32 mm dia and 800mm long PVC flexible corrugated waste pipe for wash basin/sink complete all as specified and as directed.(Prayag CAT No. 327) |
| 114 | Supply and fix 75mm diaPVC (SWR) pipes single socketed, in any length fixed to walls / floors or in trenches complete all as specified. |
| 115 | Supply & Fixed inrepairs PVC (SWR) bends 75 mm bore any radius suitable for pipe complete all as specified. |
| 116 | Supply and fix 75mm bore PVC (SWR) bends any radius, fitted with oval access door complete all as specified. |
| 117 | S&F 15mm bore steel water tubing, medium grade, galvanised with screwed and socketed joints, in any length, including supply and fixing all fittings, ISI marked conforming to IS -1239 and fixed to walls or laid in floors / trenches required for water connections complete all as specified and as directed. |
| 118 | S&F 20mm bore steel water tubing, medium grade, galvanised with screwed and socketed joints, in any length, including supply and fixing all fittings, ISI marked conforming to IS -1239 and fixed to walls or laid in floors / trenches required for water connections complete all as specified and as directed. |
| 119 | Cuttinggrooves or rebates not exceeding 20 cm girth, and trimming with or without reinforced surfaces complete all as specified and directed. |
| 120 | Cutting chases, pinning in, making good to facing where required and pointed in cement mortar 1:3 and making good cutting exceeding 10 cm girth complete all as specified. |
| 121 | Supplying, hoisting, fixing and connecting up 2000 litre rotational moulded polythylene water storage tanks double layer (cylindrical vertical with closed top), hoisted and fixed in position all as specified in SSR Part-I including connecting the overflow drain out, inlet and outlet pipes, tank nipple, elbow, bend, unions, sockets, etc. including taking down old damaged water tank and disposing off complete all as specified and as directed |
| 122 | S&F Ball valves high pressure of PTMT with epoxy coated aluminium rod & high- density plastic bal screwed for iron pipe and fixed (min wt 15mm-142gms/20mm-210gms/25mm- 455gms/40mm-690gms) for 25mm bore pipe complete all as specified and directed. |
| 123 | S&F gun metal gate valve 20mm dia, cast copper alloy, screwed down high pressure with crutch or butterfly handle screwed both ends for iron pipe complete all as specified and directed. |
| 124 | Material and labour for suspended false ceiling using E-grid 2430, 180 GSM (exposed ceiling suspension system) of grid size 600mmx600mm with main runner 38 mm x 24 mm and wall angle 24mm x 24mm using 4mm thick high Pressure Non Asbestos Fiber Cement decorative Board (E-Board Classic) in a grid of GI system duly suspended with 4 mm dia GI bar hanger fixed with steel dash fasteners or iron purline from the roof with adjustment clip providing positions for light fixtures, air conditioning diffuser and ducts, sprinkler, smoke detectors etc. The main runners to be secured to structural soffits by hanger @ 1220 mm maximum c/c. The last hanger at the end of each main runner should not be interlocked between main runners @ 610mm c/c, as to form 600 mm x 600 mm grid all as specified and directed. Make : Everest Industries Ltd or equivalent as per IS 14862 all as specified and directed. |
| 125 | M & Lfor preparation of new or previously untreated wall surfaces and applying three coats of white wash complete all as specified and directed. |
| 126 | M & L preparation of new plastered surface of walls and applying two coat of oil emulsion distemper over one coat of primer with using roller complete all as specified. |
| 127 | Material & Labour for preparation of new plastered surface applying two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm using roller complete all as specified and directed. |
| 128 | Material & Labour for preparation of new plastered surface applying two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm. |
| 129 | M & Lpreparation of new steel surfaces of any description over 10cm width or girth not otherwise described and applying two coats of synthetic enamel paint over one coat of red oxide primer complete all as specified and as directed. |
| 130 | M & Lfor preparation of new wooden surfaces of any description not other wise described over 10 cm width or girth and applying two coat of Synthetic enamel paint over a coat of pink primer complete all as specified and as directed. |
| 131 | M & Lpreparation of old steel surfaces of any description over 10cm width or girth not otherwise described and applying two coats of synthetic enamel paint over one coat of red oxide primer complete all as specified and as directed. |
| 132 | E & M Division items |
| 133 | Taking down carefully copper/aluminium point wiring (light, fan, buzzer, socket or power) complete including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc includingremoving from site for taking credit and making good to disturbed surface of walls, floors etc as per existing specification complete all as specified and as directed. |
| 134 | Taking down carefully submain wiring including all accessories without disturbing existing wiring fittings fixtures etc and making good to the disturbed surfaces all as directed and as specified in any type and size all as directed. |
| 135 | Dismantling old unserviceable main switches, sheet metal enclosures DB including MCBs etc and removing from site for taking credit incl making good to disturbed surface of wall as per existing specification complete all as specified and as directed. |
| 136 | Dismantling of U/s GI pipe of size 40 mm/50mm bore complete all as specified and directed. |
| 137 | Taking out old U/s XLPE cable of any size/type taking out of old bricks/cable cover complete all as specified and directed. (Excavation and earth work will be measured and paid separately under respective items) |
| 138 | Taking out old U/s GI PIPE of 25 to 50mm size/type including all GI fittings etc complete all as specified and directed. (Excavation and earth work will be measured and paid separately under respective items) |
| 139 | M & Lfor point wiring with FRLSH stranded copper conductor1.5 sqmm (nominal area), two single core, PVC insulated cable 1100 volts grade, ISI-694 markedin and including heavy duty, PVC Conduit including all accessories etc ISI marked, with GI sunken box suitable for fixing switches, sockets and regulators including PVC insulated FRLSH stranded copper conductor 1.5 sqmm (nominal area) single core cable as earth continuity conductor to common earth and connecting to earth dolly complete all as specified and directed for One light point controlled by one switch. |
| 140 | M & Lfor point wiring with FRLSH stranded copper conductor1.5 sqmm (nominal area), two single core, PVC insulated cable 1100 volts grade, ISI-694 markedin and including heavy duty, PVC Conduit including all accessories etc ISI marked, with GI sunken box suitable for fixing switches, sockets and regulators including PVC insulated FRLSH stranded copper conductor 1.5 sqmm (nominal area) single core cable as earth continuity conductor to common earth and connecting to earth dolly complete all as specified and directed for One fan point/exhaust fan point controlled by one, one way switch 5 Amp. |
| 141 | M & Lfor point wiring with FRLSH stranded copper conductor1.5 sqmm (nominal area), two single core, PVC insulated cable 1100 volts grade, ISI-694 markedin and including heavy duty, PVC Conduit including all accessories etc ISI marked, with GI sunken box suitable for fixing switches, sockets and regulators including PVC insulated FRLSH stranded copper conductor 1.5 sqmm (nominal area) single core cable as earth continuity conductor to common earth and connecting to earth dolly complete all as specified and directed for One 3 pin 5 Amp socket outlet point controlled by one switch on the same board. |
| 142 | M & Lfor point wiring with FRLSH stranded copper conductor1.5 sqmm (nominal area), two single core, PVC insulated cable 1100 volts grade, ISI-694 markedin and including heavy duty, PVC Conduit including all accessories etc ISI marked, with GI sunken box suitable for fixing switches, sockets and regulators including PVC insulated FRLSH stranded copper conductor 1.5 sqmm (nominal area) single core cable as earth continuity conductor to common earth and connecting to earth dolly complete all as specified and directed forOne 3 pin 5 Amp socket outlet point controlled by one switch on independent board. |
| 143 | M & Lfor point wiring with FRLSH stranded copper conductor2.5 sqmm (nominal area), two single core, PVC insulated cable 1100 volts grade, ISI-694 markedin and including heavy duty, PVC Conduit including all accessories etc ISI marked, with GI sunken box suitable for fixing switches, sockets and regulators including PVC insulated stranded copper conductor 2.5 sqmm (nominal area) single core cable as earth continuity conductor to common earth and connecting to earth dolly complete all as specified and directed for 3 pin, 15 Amp socket outlet, independent |
| 144 | M&L for point wiring with FRLSH stranded copper conductor4.0 sqmm (nominal area), two single core, PVC insulated cable 1100 volts grade, ISI-694 markedin and including heavy duty, PVC Conduit including all accessories etc ISI marked, with GI sunken box suitable for fixing switches, sockets and regulators including PVC insulated FRLSH stranded copper conductor 4.0 sqmm (nominal area) single core cable as earth continuity conductor to common earth and connecting to earth dolly complete all as specified and directed forone power point AC/Geyser equipments etc controlled by one SP/SPN MCB on independent board . Note: The point wiring will be done from DBs to the switch sockets of any size with three wires running independently for each point and with no tappings. |
| 145 | S&Fswitch piano flush type button single pole one way 5 Amps all as specified and directed. |
| 146 | S&F socket outlet 2 in 1, 3 pin 5 Amp flush type all as specified and directed. |
| 147 | S&Fswitch piano flush type button single pole one way 15 Amps all as specified and directed. |
| 148 | S&F Socket outlet 2 in 1, 3 pin, 5 and 15amp flush type all as specified and directed. |
| 149 | S&Fswitch socket combination 5 in 1 5/16 Amp flush type with all as specified and directed. |
| 150 | S&F ceiling rose surface bakelite with three terminals all as specified and directed |
| 151 | S&F Lamp holder insulated body with back platesuitable for batten fittings complete all as specified. |
| 152 | M & Lfor submain wiring with two single core 6.0 sqmm PVC insulated unsheathed cable multi-strand copper conductor FRLSH drawn through and including PVC non metallic rigid Conduit conceled with all fittings and fixing accessories on roof, walls, ceiling etc including 1 x 4.0 sqmm PVC insulated unsheathed multi strand copper conductor earth wire FRLSH connecting earth including cutting groove for concealed wiring, making good to disturb surface of wall/floor with cement mortar and finishes to match existing complete all as specified and directed. Note: Two run of single core cable, one run earth wire and one run PVC Conduit will be measured as one length. |
| 153 | Supply & Fix LED betten plastic type fitting of capacity 20W, operating on 230V, 50Hz, AC Supply having luminous efficacy of not less than 125 lumens/watts, CCT 6500K, P.F>0.9, 2.5 KV surge protection, 4-feet long, housing made out of extruded alluminium with decorative end caps elegently designed complete all as specified. |
| 154 | Supply and fixing LED luminaire 600 mm x 600 mm, 35/36 watt, 220 V AC recessed type down lighter with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete all as specified and directed. |
| 155 | Supply and fixing LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed.. |
| 156 | S&F wall mounted, compact LED batten 20 watt including LED tube rod and connecting with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directedMake : Crompton Cat No- LDLL20-WW or equivalent as per approved make list. |
| 157 | S&F LED bulb 10 watt, 5 star rated and connecting to lamp holder complete all as specified and directed.Make - Crompton Cat No LED 10W or equivalent as approved list of make |
| 158 | S&F bldg security light, LEDluminaire 30 watt made up of pressure die cast alluminium body with mid power LED as lighting sources and PC cover having Top opening separate driver compartment with IP66 protection and impact resistance of IK07 including fixing arrangements completeall as per directed by Engr- in – charge. Make - Crompton Cat No LSTS-25-CDL/NL-M or equivalent as approved list of make |
| 159 | S&F Angle bracket 40mm dia for fixing building security light of 40mm dia of 1 mtr long bent to shape 45 degree for fixing of security light including MS clamps of suitable size including nuts, bolts complete all as specified and directed |
| 160 | S&F plastic body exhaust fan 300 mm sweep complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, copper winding and connecting to ceiling rose with flexible copper cable including making holes on the wall and making good to the disturbed surfaces complete all as specified and as directed. |
| 161 | S&F plastic body exhaust fan 300 mm sweep complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, copper winding and connecting to ceiling rose with flexible copper cable including making holes on the wall and making good to the disturbed surfaces including taking down of old UNSV one and depositing to MES store yard complete all as specified and as directed. |
| 162 | S&F Metal steel body exhaust fan380 mm sweep complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, copper winding and connecting to ceiling rose with flexible copper cable including making holes on the wall and making good to the disturbed surfaces including taking down of old UNSV one and depositing to MES storeyard for keeping in safe custody complete all as specified and as directed. |
| 163 | S&F BLDC ceiling fan 1200mm sweep complete with blades, down rods and accessories, 230 V, min air delivery 210 CFM with service value 6.00 BEE 5 star rated & provn of ‘S’ type fan hook including taking down of old UNSV one and depositing to MES storeyard for keeping in safe custody complete all as specified and directed. |
| 164 | Supply & fix Wall mounting fan 400 mm sweep, operating on single phase,230V, AC, 50 Hz having speed of 1400 RPM, air delivery 115 CMM, power output of 100W star rated along with blade, canopy, mounting brackets, rubber insulator complete all as specified and directed. |
| 165 | Supply and fix electric water heater, storage type steel body with copper inner tank and heating element upto 2 KW capacity 25 litre, BEE 5 Star rated complete with all accessories such as safety valve, thermostate, NRV, connection pipe etc complete all as specified and as directed. |
| 166 | S&F metal plug socket with MCB SP 20 Amp, 240 V enclosure for AC/equipment with neutral and earth point complete all as specified and directed. |
| 167 | S&F sheet metal enclosure powder coated single phase DB for fixing of MCBs, 4 way double door with bus bar includinggrouting on the wall by means of screws and rawal plugs and making good disturbed surfaces complete all as specified and directed. |
| 168 | S&F sheet metal enclosure powder coated single phase DB for fixing of MCBs, 8 way double door with bus bar includinggrouting on the wall by means of screws and rawal plugs and making good disturbed surfaces complete all as specified and directed. |
| 169 | S&F sheet metal enclosure powder coated three phase and neutral DB for fixing of MCBs, 4 way double door with bus bar includinggrouting on the wall by means of screws and rawal plugs and making good disturbed surfaces complete all as specified and directed. |
| 170 | S&F MCB TPN of capacity 63 Amps ,240 V, 10 KA \"B\" curve complete all as specified and directed. |
| 171 | S&F MCB SPN of capacity 40-63 Amps,240 V, 10 KA \"C\" curve complete all as specified and directed. |
| 172 | S&F MCB SP of capacity 5-32 Amps,240 V, 10 KA \"C\" curve complete all as specified and directed. |
| 173 | Supply , installation, testing and commissioning, CPRI approved factory made and tested, LT feeder pillar box, outdoor type of size 1100mm x 1000mm x 350mm platform mounted. The panel shall be dust and vermin proof, IP65 class protection and madeout of 3.15 mm thick CRCA MS Sheet and 50x50x5mm thick angle iron frame work, powder coated finish over one coat of red oxide primer outside and two coats of red oxide primer on inside, front opening type, with aprons for cable entry, with double door shutter and locking arrangement, internal wiring with 2.5 sqmm PVC insulated, stranded copper conductor cable, IS-694 marked of adequate size and internal connection from MCCBs, MCBs and TPN aluminium bus bar and extension links of rating not less than 1.5 times the rated capacity of the respective MCCBs. The TPN bus bar and extension links shall be insulated with colour code heat shrinkable sleeve and shall be mounted epoxy regin insulator to contactor not less than 10 sqmm single core copper cable stranded copper conductor cable, IS-694 marked. The following items accommodated with this feeder pillar including 02 Nos danger notice plate made of 1.6mm thick mild steel sheet, vitreous enamelled white of size 25 x 20cm with letter figures and conventional skull bones in signal red colour and fixed nuts, bolts and washers etc with voltage and danger indicated in Hindi and English complete all as specified and directed. The scope of work includes the following items accommodate the same panel:- |
| 174 | Incoming:(a)MCCB 4 pole, 415 volts AC grade, 250 Amps, 25 kA Ics = 100%Icu (Make: Legrand/Schnider/SIEMENS) - 01 No (b) Digital voltmeter (0-500V) with selector switch = 01 No(c) Digital ammeter (0-400 Amp) incl CT (ratio 400/5) = 01 No and selector switch = 01 No(d) LED lamps for phases indication R-Y-B = 01 setOutgoing:(a) MCCB 4 pole, 415 volts AC grade, 160 Amps, 16 kA Ics = 100%Icu (Make: Legrand/Schnider/SIEMENS) - 04 Nos (b) Digital ammeter (0-400 Amp) incl CT (ratio 400/5) = 01 No and selector switch = 01 Nos(c) Analog Street Light Timer - 01 NoNote: Foundation for the panel should provide with PCC 1:4:6 at a depth of 150mm beow ground level and 100mm above the ground level with slot openings for I/C and O/G cables. |
| 175 | Material and labour as in replacement for earthing complete with galvanised iron earth plate electrode 600 mm x 600 mm x 6 mm thick, burried directly and preferably vertically in ground, earth pit not less than 2.25 Mtr deep below ground level with top edge of the plate not less than 1.5 m below ground level connetced with galvanised strip of size 25mmx4mmby means of nuts, bolts, check nuts and washers made of galvanised iron or steel earthing lead to be protected by galvanised iron pipe of 40mm (light grade) and other end connected to earthing test point or lightening arrestor or main controlling switch as directed including providing funnel with 20mm bore galvanised iron pipe (medium grade), wire mesh, charcoal or coke and common salt in alternate layer of 15cm (compacted thickness) all round the earth electrode, concrete earth pit in PCC (1:3:6) type C-1 (with 20mm graded aggregate), 50mm thick precast RCC (1:2:4) cover slab (re-inforced with 8mm dia TMT bar @ 15 cm C/C bothways and suitable handle made of 10mm dia) including necessary earth work in excavation, returning filling and removal of surplus earth upto a distance not exceeding 50 m etc all as shown on electrical plate No. 3 of MES Schedule Part-I(2009) complete including testing on completion all as specified and as directed. |
| 176 | M & Lfor new earthing with galvanised steel earth plate electrode 600mmX600mmX6mm thick burried directly in ground (earth pit not less than 2.25 mtr below ground level) with top edge of the plate not less than 1.5 mtr below ground level connected to 4mm dia GI wire protected by 20 mm bore light grade galvanised iron pipe and other end connected to test point as directed including funnel with wire mesh and watering pipe 20 mm bore medium grade galvanised iron pipe with charcoal and common salt in alternaterlayers of 15 cm thickness all around the GI plate electrode with concrete pit in PCC 1:3:6 type C-1 with cast iron frame including cast iron cover 10mm thick hinged to CI frame and 6mm MS rod for handle, necessary excavation and earth wok in hard/dense soil and disposal of spoil to a distance n exc 50 m and necessary testing complete all as shown in electrical plate No 3 of SSR part-I complete all as specified and directed. |
| 177 | Taking out old existing earthing and M & Lfor new earthing with galvanised steel earth plate electrode 600mmX600mmX6mm thick burried directly in ground (earth pit not less than 2.25 mtr below ground level) with top edge of the plate not less than 1.5 mtr below ground level connected to 4mm dia GI wire protected by 20 mm bore light grade galvanised iron pipe and other end connected to test point as directed including funnel with wire mesh and watering pipe 20 mm bore medium grade galvanised iron pipe with charcoal and common salt in alternaterlayers of 15 cm thickness all around the GI plate electrode with concrete pit in PCC 1:3:6 type C-1 with cast iron frame including cast iron cover 10mm thick hinged to CI frame and 6mm MS rod for handle, necessary excavation and earth wok in hard/dense soil and disposal of spoil to a distance n exc 50 m and necessary testing complete all as shown in electrical plate No 3 of SSR part-I complete all as specified and directed. |
| 178 | Supply, fixing, commissioning & testing of XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, Electric power cable (heavy duty) with aluminium conductors, 1100 volts, grade cross sectional area 95 sqmm 3.5 core laid in trenches/fixed to wall/under road/pipe etc with copper cable glands & copper thimbles complete all as specified and directed. |
| 179 | Supply, fixing, commissioning & testing of XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, Electric power cable (heavy duty) with aluminium conductors, 1100 volts, grade cross sectional area 25 sqmm 3.5 core laid in trenches/fixed to wall/under road/pipe etc with copper cable glands & copper thimbles complete all as specified and directed. |
| 180 | Supply, fixing, commissioning & testing of XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, Electric power cable (heavy duty) with aluminium conductors, 1100 volts, grade cross sectional area 6 sqmm 2.0 core laid in trenches/fixed to wall/under road/pipe etc with copper cable glands & copper thimbles complete all as specified and directed. |
| 181 | Material & labour GI tube light grade 40 mm bore for protection of cable complete all as specified and directed. |
| 182 | Material & labour GI tube light grade 25 mm bore for protection of cable complete all as specified and directed. |
| 183 | M&L for steel water tubing 50mm dia, medium grade galvanised with new fitting laid in trenches or on wall complete all as specified and directed. |
| 184 | M & Lfor steel water tubing 25mm dia, medium grade galvanised with new fitting laid in trenches or on wall complete all as specified and directed. |
| 185 | S&F gun metal gate valve 50mm dia, cast copper alloy, screwed down high pressure with crutch or butterfly handle screwed both ends for iron pipe complete all as specified and directed. |
| 186 | S&F gun metal gate valve 25mm dia, cast copper alloy, screwed down high pressure with crutch or butterfly handle screwed both ends for iron pipe complete all as specified and directed. |
| 187 | M & L100mm thickPCC 1:3:6 type C2 using 40mm graded crushed stone aggregate for flooring complete all as specified and directed. |
| 188 | M&L for cutting of existing GI pipe line 50mm dia for inserting Tee and reducer etc for taking 50mm dia branch pipe including fittings complete |
| 189 | M & Lfor cutting of existing GI pipe line 25mm dia for inserting Tee and reducer etc for taking 25mm dia branch pipe including fittings complete |
| 190 | Excavation in trenches not exceeding 1.50 m wide and n.exc 1.5 m in depth for foundation of poles, cable etc, not exc 10 sqm on plan and getting out in soft/loose soil including taking out brick protection etc complete all as specified and directed. |
| 191 | Returning, filling in, including spreading, leveling, wateringand well ramming in layers not exc 25cm thick complete all as specified and directed. |
| 192 | Removing excavated materials (soils) not exc. 50m and depositing where directed at a level not exc. 1.5m above the starting point complete all as specified and directed. |
| 193 | M & L for sand cushioning by spreading in trenches crushed sand by gently by punning down manually as in cable protection all as specified and as directed by Engineer -in-charge.Note : Thickness of sand cushioning after punning down will be measured. |
| 194 | M&L for bricks sub-class \"B\" laid in trenches in flat style (width portion in horizontal shape) for cable protection complete all as specified and directed. |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
| 5 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail