| Sl. No. | Item Description |
| 1 | Demolition of brick work or stone/ boulder masonary, built in cement mortar or cement lime mortar including all quions, arches, pillars, etc. but excluding ashlar facing, dressed stone work and precast concrete articles etc. complete all as specified and directed. |
| 2 | M&L for brick work with fly ash old sizebricks straight or curved on plan exc 6 m mean radius built in cm (1:6) complete all as specified and directed. |
| 3 | Taking down cement plaster or cement lime plaster on PCC/stone surface/brick surfaces including raking out joints hacking for key scrubbing down with water etc complete all as specified and directed. |
| 4 | M&L for 15mm thick rendering on fair faces of brick or stone wallsin CM 1:6 finished even and smooth without using extra cement complete all as specified and directed. |
| 5 | M&L for 5 mm thick rendering in cement mortar (1:3), finished even and fair without using extra cement on brickor concrete surfacesof ceiling complete all as specified and directed. |
| 6 | M&L for rendering 15 mm thick in cement mortar (1:4) on fair faces of brick work or concrete surface mixed with water proofing compound @ 3% by weight of cement or as per manufacturer\"s instructions, finished even and fair without using extra cement complete all as specified and directed. (Note : WPC shall be measured & paid separately) |
| 7 | Supply only liquid water proofing compound ISI marked complete all as specified and directed. |
| 8 | M&L for 1 mm thick wall care putty on internal wall over old/new plastered/ unplastered or newly plastered surfaces complete all as specified and directed. |
| 9 | M&L for preparation of old decorated plastered or unplastered surfaces of walls and applying two coat of oil bound distemperIncluding cleaning of entire surface complete all as specified and directed. |
| 10 | M&L for preparation of new plastered surfaces and applying two coats of oil emulsion distemper complete all as specified and directed. |
| 11 | M&L for preparation of newly plastered surafces of wall and applying two coats of water based preimum acrylic smooth exterior emulsion of approved colour complete all as specified and directed |
| 12 | M&L for preparation of old plastered surafces of wall and applying two coats of water based preimum acrylic smooth exterior emulsion of approved colour complete all as specified and directed |
| 13 | M&L for preparing of newly plastered ceilingsurface andapplying two coats of whitewash complete all as specified and directed. |
| 14 | M&L for preparation of old plastered or unplastered surface of ceiling including cornices etc. by brooming down or steel wire brushing, scrapping down smoke soot, moulds, moss and efflorescent salt and trading oil and greasy spots and removal of vegetation and applying one coat of white wash complete all as specified and directed. |
| 15 | Dismantling, floor hearth or wall tiling inclduing cement mortar bedding and removing rubbish off the premises complete all as specified and directed. |
| 16 | M&L for vitrified ceramic coloured tiles of8 to 10mm thick area of each tile not exc 0.36 Sqm in floor, shelves etc, set and jointed in neat cement slurry & pointed in coloured cement to match the shade of tiles over and including 15mm thick screed bed or bedding layer in cement mortar 1:6 complete all as specified and directed. |
| 17 | M&L for vitrified ceramic coloured tiles 8 to 10 mm thick polished (square/ rectangular) area of each tile not exc 0.36 Sqm, in skirting etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match including 10mm thick back coat in CM 1:4 complete all as specified and directed. |
| 18 | M&L for joint free non skid, ceramic “coloured” digital tiles7 to 8mm thick area of each tile exceeding 0.06 and n.exc 0.11 Sqm in floor etc, set and jointed in neat cement slurry & pointed in coloured cement to match the shade of tiles over and including 15mm thick screed bed or bedding layer in cement mortar 1:6 complete all as specified and directed. |
| 19 | M&L for Glazed ceramic colouredtiles 300 mm x 450 mm x 7 mm thick, in skirting, dados, risers to steps, etc se and jointed in neat cement slurry, and pointed in coloured cement to match tiles over and including 10mm thick renderingor backinglayer in cement mortar 1:4 complete all as specified and directed. |
| 20 | M&L for Granite 15-18mm thick (of any type) work (table rubbed and polilshed) for wall lining (veneering to wall) 12mm thick in cement mortar (1:3) and pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite over 10 mm thick rendering back coat in cement mortar 1:4 complete all as specified and directed. |
| 21 | Dismantling PVC water tanks and removing for capacity exceeding 500 litres & not exceeding 1000 litres etc., complete all as specified and directed. |
| 22 | S&F for rotational moulded,multilayer HDPE water storage tank of 1000 ltrs capacity (Cylindrical vertical with closed top)ISI marked fixed in position on existing places complete all as specified including 02 Nos 20mm dia full threaded GI tank niple, 20 mm dia PTMT float valve epoxy coated Aluminium rod with high density plastic float ball (of minium weight 210 gms), tank cover etc complete all as specified and as directed. |
| 23 | S&F in repair 600mmx450mm bevelled edge mirror of selected quality glass, mounted on 6mm thick AC building board or commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers complete all as specified and directed. |
| 24 | S&F 5mm thick looking mirror with bevelled edges including suitable SS studs complete all as specified and directed |
| 25 | S&F in repair gun metal globe or gate valve with iron wheel head, screwed both ends for iron pipe and fixed of 20 mm bore, complete all as specified and directed. |
| 26 | Taking up or down steel water tubing and connections of 15mm bore, fixed in walls, ceiling, floors, trenches etc. complete all as specified and directed. |
| 27 | Taking up or down steel water tubing and connections of 20mm bore, fixed in walls, ceiling, floors, trenches etc. complete all as specified and directed. |
| 28 | Taking up or down steel water tubing and connections of 25mm bore, fixed in walls, ceiling, floors, trenches etc. complete all as specified and directed. |
| 29 | S&F GI Steel water tubesmedium grade, ISI marked, galvanised, 15mm bore with all fittings, fixed to walls and ceiling or laid in floors complete including taking down complete all as specified and directed. |
| 30 | S&F fpr GI Steel water tubesmedium grade, ISI marked, galvanised, 20mm bore with all fittings, fixed to walls and ceiling or laid in floors complete including taking down all as specified and directed. |
| 31 | S&F for GI Steel water tubesmedium grade, ISI marked, galvanised, 25mm bore with all fittings, fixed to walls and ceiling or laid in floors complete including taking down complete all as specified and directed. |
| 32 | M&L for Cutting chases pinning in making good to facing where required for concealed water tubingand making good cutting not exc 10cm girth in brick walls complete all as specified and directed. |
| 33 | S&F in repair vitreous china wash hand basin white, flat back of size 550mmx400mm fixed on and including cast iron cantilever bracket and cutting for and pinning in ends brackets or erecting stand,32mm waste pipe fitting etc complete all as specified and directed. |
| 34 | S&F in repair (Swan neck type) Pillar taps 15mm dia, cast copper alloy, with capstan heads, fancy type, chromium plated, quarter turn, screwed down high pressure, with or without lettered ‘Hot’ or ‘Cold’ with long screwed shanks and fly nuts, screwed for iron pipe 15 mm bore complete all as specified and directed. |
| 35 | S & Fin repair waste coupling of CP (half or full threaded) (minimum weight 32mm- 45gms/ 40mm-60gms of 32mm dia for WHB complete all as specified and directed. |
| 36 | S&F in repair vitreous china urinal, half stall type (flat back), of size 635x395x420mm, white, with grating and union for discharge pipe (excluding flushing cistern) including 32mm dia PTMT coupling and waste pipe, CP urinal spreader providing and fixing plugs, bedding urinal against wall in CM 1:2, complete all as specified and directed. |
| 37 | S&F in repair 25mm dia stainless steel pipe as in drapery/curtain rodsincluding brackets and fancy type end knobs, complete, all as specified and directed. |
| 38 | S&F in repairCP angle valve 15 mm bore, fancy type cromimum plated with long shank and cup, high pressure crutch or butter fly handle, quarter turn screwed both ends screwed for iron pipe or for unions (weight of each should not be less than 0.40kg) complete all as specified and directed. |
| 39 | S&F in repairCP Stop valve 15 mm bore, fancy type cromimum plated with long shank and cup (concealed type), high pressure crutch or butter fly handle, quarter turn screwed both ends screwed for iron pipe or for unions (weight of each should not be less than 0.40kg) complete all as specified and directed. |
| 40 | S&F in repair two way angle valves /bib tap with flange 15mm bore, fancy type, quarter turn, cast copper alloy, chromium plated with long shank and cup screwed down, screwed both ends for iron pipe or for unions complete all as specified and directed. |
| 41 | S&F in repair Health faucet (ABS Body) mild steel chromium plated suitable for 15 mm dia pipe with 1.25 metre long flexible tube and ABS wall hook including making connections and fixed in position complete in all respect as specified. complete all as specified and directed. |
| 42 | S&F in repair vitreous china wash down water closet pan (Pedestal pattern) with \"P\" or \"S\" trap white, including connection to trap and cistern, flush pipe including white plastic water closet seat cover, closed pattern with flat bottom & cover and aluminium anodised hinging device and making good disturbed surface of floor complete all as specified and directed. |
| 43 | S&F in repairs PVC valveless symphonic action type low level flushing cistern (ISI marked) of 10 litre capacity including32 mm dia PVC flush pipeconnected to water closet with inlet, ball valve, float and handle complete all as specified and directed.. Make: Commander/ slimline/ waterbird |
| 44 | S&F in repair PVC connection 15 mm size with PTMT nuts of length 450mm complete all as specified and directed. |
| 45 | S&F in repair for grating doom 100 mm dia of SS with/without waste hole (Minimum weight 25gms) complete all as specified and directed. |
| 46 | S&F in repairbib taps with wall flange 15mm bore, fancy type, quarter/half turn, chromium plated, long body with capstan head and cup screwed down, complete all as specified and directed. |
| 47 | S&F in repair ABS body chrome plated shower rose 125 mm size Square or round , shower Arm with swivel joints complete all as specified and directed. |
| 48 | S&F in repair Tubular towel rail of brass chromium plated, 20 mm dia, \"D\" type, 60 cm long between flanges complete all as specified and directed. |
| 49 | S&F in repair SS Towel ring chromium plated complete all as specified and directed. |
| 50 | S&F in repair Soap dish, stainless steel, fixed to plugs with chromium plated brass screws complete all as specified and directed |
| 51 | S&F in repair Sheet glass shelf assembly consisting of 5.5mm thick sheet glass shelf 12cm wide with chromium plated bracket guard and railing 60cm long complete all as specified and directed. |
| 52 | S&F in repair PVC (SWR) floortrap plain with grating with waste hole including jointing with solvent cement 75 mm dia complete all as specified and directed. |
| 53 | Taking down door chowkhat with shutter area n-exc 1.5 Sqmeach (without taking off shutters from the frame) complete all as specified & directed. |
| 54 | Taking down chowkhats or frames with shutters exc 1.5 Sqm but not exc 4 Sqm each (without taking off shutters from the frame) complete all as specified & directed. |
| 55 | Factory made single extruded WPC (Wood Polymer Composite) solid door/ window/ Ceosetory windows & other Frames/ Chowkhat of size 50 x 125 mm comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/ cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modules of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/ moisture proof and fire retardant and fixed in position with MS hold fast/ lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-in-Charge. (M.S. hold fast/ lugs or SS dash fasteners shall be paid for separately). Note: For WPC solid door/window frames, minus 5mm tolerance in dimension i.e. depth and width of profile shall be acceptable. Variation in profile dimensions on plus side shall be acceptable but no extrapayment on this account shall be made. |
| 56 | Description same all as per item serial No 55 here-in-above but of Frame size 65 x 125 mm complete all as specified and directed. |
| 57 | Supply & Fixing of bands, straps, supports or stays for rainwater, ventilating pipes, including bolts, if required: hooks (stay), heavy, for large gates; hook and pintle hinges: large hasps andtaples; chains; hand made sliding bolts; clamps; hold fasts; wall ties; hooks for hanging fans; plain angle cleats for securing purlins to wood trusses or rafters; knee piece inserts; two way and three way straps, plate washers and similar small articles conforming to Fe-290 Gde-E-165 complete all as specified. |
| 58 | M&L for PCC 1:2:4 type B-1 using (20mm graded stone aggregate) as in bed blocks for hold fast complete all as specified & directed. |
| 59 | M&L for two coats of synthetic enamel paint over a coat of red oxide on new steel surfaces , over 10 cm in width or grith not other wise described complete. |
| 60 | Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid decorative type flush door shutter of size 30mm thick comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category withproperty of being termite/borer proof, water/moisture proof and fire retardant. WPC to be laminated with PVC foil of minimum 14 microns thick of approved design pasted with hot melt adhesive on both faces of shutter and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer- In- Charge. (Note: stainless steel butt hinges and necessary S.S screws shall be paid separately) |
| 61 | S&F 30mm thick FACTORY MADE WIRE MESH SOLID WPC DOOR SHUTTER consisting of Density 650 Kg /Cbm Manufactured by an ISO-9001-2015 certified Company , Door to be panelled with SS mosquito Mesh and XTN aluminium Mesh for additional strength and safety purpose. (confirming as perS:4020). The door should be water proof, termite proof, fire retardant and having screw holding capacity. Door to be fixed to frame with 3 nos. M.S powder coated butt hinges size 100mm*25mm*2mm and 32mm long steel screws drilled suitable to pass through both the walls of the M.S tube.Other hardwares should be fixed with 19*6mm size steel screws etc.complete all as specified and directed as per manufacturer\"s specification & drawings. |
| 62 | S&F 200 mm long Stainless steel tower bolt complete all as specified and directed |
| 63 | S&F150mm long stainless steel handlecomplete fixed with steel screws complete all as specified and directed. |
| 64 | S&F 300 mm long stainless steel sliding door bolt plate typewith bright bolt not less than 12mm dia with & including a min of 6 bolts & nuts four on bolt plate & two on staple plate & fixed complete all as specified and directed. |
| 65 | S&F 100mm size stainless steel butt hinges for doors complete all as specified and directed. |
| 66 | S&F SS 150mm Floor door stopper with hard drawn steel spring, fixed in floor complete all as specified & directed |
| 67 | S&F for casement windows with net & grill single or multi shutter turn window are made out of UPVC multi-cavity frames sections of 60X60X2.5mm suitably reinforced and double multi-shutters division are made by using sash million having 50X64X2.5mm multi-cavity UPVC section, suitably reinforced with GI and shutters are made out of 50X85X2.5mm UPVC section reinforced and welded in corners with EDPM gaskets provision for glass and for air tightt at frames and outer side of shutter with single glaze window shutters using suitable glass bead with perfect hardware like hinges, handles,stays etc complete. Mosquito mesh shutter is made out of UPVC extruded section of 61X27X2mm with GI channel of 1.2mm thick, welded in corners. Mosquito net of GI is filled in shutter with proper required accessories like hinges,MS grill of 12mm square MS bar are inserted in main frame & screwed by hidden screwing system with powder coating etc complete all as specified and directed. (Note: glazed shutters float glass thickness not less than 4.00mm and wiremesss shutter with SS wire mesh 0.36mm dia with aperture 1.4mm shall also be deemed included in quoted rates and no extra payment will be made separately) |
| 68 | S&F for UPVC ventiliatorsmade out of UPVC multi-cavity frames sections of 60X60X2.5mm suitably reinforced and double multi-shutters division are made by using sash mullion having 50X75X2.5mm multi-cavity UPVC section, suitably reinforced with GI and shutters are made out of 60X75X2.5mm UPVC section reinforced and welded in corners with TPE gaskets provision for glass and for air tightt at frames and outer side of shutter with single glaze window shutters using suitable glass bead with perfect hardware like hinges, handles,stays etc complete. with MS grill of 12mm thick round shape are fabricated as per manufacturer and installed in UPVC frame section of 35X35X2mm by drilling and surveying system complete all as specfied and directed.(Note: glazed shutters float glass thickness not less than 4.00mm and wiremesss shutter with SS wire mesh 0.36mm dia with aperture 1.4mm shall also be deemed included in quoted rates and no extra payment will be made separately) |
| 69 | S&F in repair Galvanised mild steel wire cloth.0.63mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staplescomplete all as specified & directed. |
| 70 | Dismantling wall and ceiling boards or insulation boards, any thickness, any description, including cover fillets complete all as specified and directed. |
| 71 | S&F for 4mm thick E-boards tiles (Make: Everest) false ceiling fixed in repair with powder coated GI snap grid frame work (Make: Armstrong/Saint Gobain or equivalent as approved) including cutting holes in brick wall built in cement mortar & making good in cement concrete 1:2:4 type BO/Cement mortar 1:3 complete all as specified and directed including all necessary drilling and necessary arrangement to fix electrical items as under:- (a)25x25x1.6mm thick GI angle powder coated duly plugged @ 600mm centre to centre along perimeter of wall.(b)25x25x1.5mm thick GI tee powder coated as main and cross runners suspended with 1.6mm dia GI wire suspenders with adjustable clamps and dash free fastners plugging in RCC slab placed @ 600mm centre to centre from perimeter of wall. (c)Fixing of 4mm thick E-boards tiles of size 595x595mm of approved texure and finished complete with two coats of oil emulsion distemper on ceiling.NOTE: The complete ceiling work shall be done as per manufactures instruction and as directed. |
| 72 | Dismantling structural steel work including doors, gates but excluding framed trusses etc complete all as specified and directed. |
| 73 | M&L for structural steel work with rolled mild steel sections as in main and cross beams, hip and jack rafters, purlins where connected to common rafters and running rails and guides for sliding doors; hollow sections etc fixed with angle cleats or other connecting plates conforming to Fe-290 (Gde E-165) quality A complete all as specified and directed. |
| 74 | S&F for 1.25mm thick Mild steel, plain, black sheet in wall cladding, steel gates and similar work, cut to size, holes punched; including round headed screws, clout nails or rivets and fixed to wood or steel framing withplain 40 mm lap joints with riveted or welded seams, including bending or turning up, mitred angles, etc. as required complete as specified and directed |
| 75 | Dismantling plain or corrugated steel sheeting any gauge thickness including nanital or similar pattern roof covering complete all as specified and directed. |
| 76 | M&L for Prepainted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws all as specified & directed. |
| 77 | M&L for Prepainted galvalume aluminium zinc coating GI based plain steel sheet0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws all as specified & directed. |
| 78 | Demolition of cement concrete (unreinforced) in ground floors and pavings not exc. 15 cm thickness (below or above ground level) complete all as specified and directed. |
| 79 | M&L for PCC 1:2:4 type B0 using 12.5 mm graded stone aggregate as in roof curbing, padding over roof slab complete all as specified and directed. (Note - Average thickness shall not exceed 40mm complete all as specified and directed. |
| 80 | M&L for rendering 10 mm thick on concrete surface when concrete is green on roof surface in cement mortar 1:3 complete all as specified and directed. |
| 81 | Supplying and applying High build elastomeric waterproofing coating based on pure, hydrophobic polyurethane, cold applied of spray / brush applied, SmartCare PU Magnum membrane with an elongation of 550% and tensile strength of 2.5 N/mm2 as per ASTM D 2370, crack bridging ability of 3mm as per ASTM C1305, no leakage upto 7 bars of water pressure asper DIN 1048, shore A Hardness of min. 45 as per ASTM D 2240. The system includes final base preparation, epoxy primer application and applying SmartCare PU Magnum or approved equivalent in two coats with a consumption of 1.5 Kg per SQM on a primed surface withSmartCare Primer and a 40 GSM geo textile cloth sandwiched in between, etc., complete as perManufacturer\"s specifications |
| 82 | M&L for 75 mm thick PCC 1:3:6 type C2 using 40 mm graded crushed stone aggregate as inplinth protection surface finished fair and even without using extra cement complete all as specified. |
| 83 | S&F in repair stainless steel six peg hanger chromium plated as approved by engr-in-chargecomplete all as specified and directed. |
| 84 | Demolition and breaking up or taking down PVC/AC/CI/SSW 100mm/75mm bore pipe drain pipes,set in cement mortar including PCC haunching and bedding, complete all as specified and directed. |
| 85 | S&F for 110mm bore PVC (SWR) pipessingle socketed in any length with rubber ring joints fixed to wall including PVC holding clamps,complete all as specified and directed. |
| 86 | S&F for 75mm bore PVC (SWR) pipessingle socketed in any length with rubber ring joints fixed to wall including PVC holding clamps, complete all as specified and directed. |
| 87 | S&F in repair PVC (SWR) bends any radius, 75 mm bore ccomplete all as specified and directed. |
| 88 | S&F in repairPVC (SWR) bends any radius, 110 mm bore complete all as specified and directed. |
| 89 | M&L in repair PVC(SWR) gully trap 125/110mm, setting and jointing with solvent cement complete all as specified and directed. |
| 90 | Demolition of Stone slabs and tiles laid dry or laid dry and pointed of any description or thickness in floors, aprons etc complete all as specified and directed. |
| 91 | M&L forheavy dutypavement tiles 400mmX400mmX10mm thick coloured for floor/pavement etc & jointed in neat cement slurry and pointed with white cement fixed with colour pigment to match colour of tilesincluding 15mm thick screed bed in CM 1:4 complete all as specified and directed. |
| 92 | M&L for providing cement concrete 1:2:4 type B-0 using 12.5 mm graded stone aggregate as in coping on edges of tiles, rounded or chamfered on edges complete all as specified and directed. |
| 93 | Dismantling posts or struts (wood, steel or R.C.C.) any section, Posts embedded in Concrete, brick work, masonary etc including taking out embedded portion and making good disturbed ground complete all as specified and directed. |
| 94 | Dismantling Galvanised mild steel barbed wire, any thickness complete all as specified and directed. |
| 95 | Dismantling fencing wire mesh, chain link any type complete all as specified and directed. |
| 96 | Excn in post holes ( or similar holes) in soft / disintegrated rock each n.exc 0.5 cum getting out, returning filling in and ramming earth or broken rubble mixed with earth around in layers not exceeding 25 cm watering and removing surplus soil to a distance n.exc 50 M complete all as specified and directed. |
| 97 | M&L for Plain cement concrete 1:3:6 type C-2, using 40mm graded crushed stone aggregate as in walls or retaining walls, any thickness, size or shape including pilasters, buttrresses, columns, pillars, boundry pillars and posts (including, caps and bases) complete all as specified and directed. |
| 98 | S&F for Mild steel work as in swan necks for fencing, posts and struts including cutting tops to shape as directed, drilling holes, notching for wire , etc.; flat iron fillets ( for securing wire mesh etc. including all necessary drilling , bolting or rivetting , etc., and similar work conforming to Fe- 290-Gde E-165 complete all as specified and directed. |
| 99 | M&L for Preparation of new steel surfaces of any description not otherwise described n exc 10 cm width or girth and applying two coats of synthetic enamelled paint over one coat of red oxide Zinc chrome primer complete all as specified and directed. |
| 100 | Fixing only chain link fencing including line wires, any mesh , size and type to any type of standards , rails , straining bolts, etc. including provision of binding wire complete all as specified and directed. |
| 101 | Supply only Chain Link MS galvanised fencing, diamond square type, complete all as specified and directed. |
| 102 | S&F for concertina coil 600 mm dia (stretched position) hot dip galvanised including “U” and “C” clip, having 50 Nos of spirals in 8 mtr stretch length and composed of reinforced punched razor ribbon sides of cold rolled low carbon steel fixing of the “Y” of trapezoidal shaped angle iron brackets placed at 2.5 to 3 meter apart complete all as specified, shown in drawings complete all as specified and directed. The barbs should have 180 degree straightness, razor edge cut with following specifications:-(i) Concertina coil confirming to IS-513, IS-4454 (Part-1) and IS-12753 (ii) Clips-18 SWG GI (iii) Wire dia-2.60 mm(iv) Razor blade tape length-20 mm (minimum) (v) Razor blade tape width- 14 mm (minimum) (vi) Razor blade thickness- 0.50 mm(vii) Clips per round of circle-05 Nos(viii) Zinc coating- 230 to 240 GSM heavy coating hot dip (ix) Tensile strength- 1620 N/ Sqmm (minimum) Note: (a)Horizontal razor wire and angle iron supports will be measured and paid separately under relevant items of Sch ‘A’/ BOQ. (b)Measurement will be made for stretched length. |
| 103 | S&F for hot dip galvanised razor wire fencing with 2.60 mm dia centre core wire having barbs of length 20mm (minimum), width 14mm (minimum) and thickness 50mm razor strip on swan neck angle iron and fixing with antirust clamps on angle iron post including all fittings like fastener clips, steel leg rings etc as shown in drawing complete all as specified and directed. The barbs should have 180 degree straightness, razor edge cut with following specifications.(i) Razor wire confirming to IS- 513, IS 4454 Part-I and IS-12753(ii) Zink coating- 230 to 240 GSM heavy coating hot dip.(iii) Tensile strength- 1620 N/Sqmm (minimum)Note: Each line of wire will be measured. |
| 104 | Excavation in trenches in any type of soil not exceeding 1.5mtr wide & not exceeding 1.5mtr deep for foundation, laying of cable/pipes etc (where provided for protection of cable/pipe) and getting out grimming of sides, forming bottom surfaces to required level |
| 105 | M&L for PCC 1:4:8 type D-2 (using 40mm graded stone aggregate) as in foundation filling and mass concrete complete all as specified and directed. |
| 106 | Form work to sides fo concrete foundations, footings base of column, raft and raft beams, side & soffits (if any) of foundations and plinth beams and similar work ; vertical or to better for fair finished flat surfaces of concrete complete all as specified and directed. |
| 107 | M&L for RCC (1:2:4) type B1 (using 20mm graded aggregate) as in Foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc all as specified and directed. |
| 108 | M&L for RCC (1:2:4) type B1 (using 20mm graded aggregate) as in column etc all as specified and directed. |
| 109 | S&F TMT steel bars 10mm dia and over , cut to length, bent to shape required , including cranking , bending spirally for hooping for columns, hooking ends and binding with the including mild steel wire (annealed ) not less than 0.9mm dia complete all as specified. |
| 110 | M&L for TMT bar 5mm dia & over cut to length as in stirupps, bent to shape as required including cranking,bending .hooking end and binding with steel wire annealed not less than 0.9mm or securing with dips complete all as specified and directed. |
| 111 | M&L for brick work with fly Ash bricks in CM 1:4 straight or curved or plan not exc.6mtr mean rediusall as specified and directed. |
| 112 | M&L for Granite (of any type) work (table rubbed and polished) for wall lining (veneering to wall) 12mm thick in cement mortar (1:3) and pointing with white cement (1:2) using marble dust with admixture of pigment to match with shade of granite.including backing coat of plaster in CM 1:3, 15 mm thick complete all as specified and directed. |
| 113 | Rounding to edges of stone slabs one edge, such as in steps, cooking platform, and other similar situations complete all as specified. |
| 114 | M&L for framed work as in doors or gates, of angle or other section with gusset plates, rails, braces etc complete drilling for fixing of steel sheeting or other covering or slidding with including either hooks and hings or steel hanging door fittings (exclusive of steel sheeting or other covering running rails and gudes) and ganging also fastening and complete with ornamental design Fe-290, grade E-165 also specified and directed. |
| 115 | Returning and Filling in with excavated soil including spreading , leveling, watering and well ramming in layers n.exc 25 cm thick complete all as specified and directed. |
| 116 | Removing of excavated material (surplus soil) to a distance exceeding 50 mtr but not exc 250 mtr and depositingat a level not exceeding 1.5 mtr above the starting point complete all as specified and diercted. |
| 117 | Taking down carefully aluminium batten point wiring for light/fan/socket/bell or power point incluidng all fitting / fixtures i.e switche, socket, ceiling rose, regulator, batten holder, etc complete and making good disturbed surfaces of wall/floor to match with the surroundings of wall/ceiling/floor etc including taking down old light fittings. Note : (i)Contractors quoted rate of this item deemed inclusive of unscrewing of the serviceable fittings and fixtures as directed.(ii) Qoted rate also deemed to be included cost of cutting chases for taking out concealed conduit and nitch for terminal box.(iii) Exhasut Fan and Ceiling Fan shall be taken down in under separate item of this schedule. |
| 118 | M&L for point wiring with FRLSH PVC insulated unsheathed multistranded copper conductor cable 1.5 Sqmm (nominal area) 1100 Volts graded concealed in the wall/roof alongwith one single run of same size and type of copper wire as contineous earth wire to common earth dolly drawn in and including non metallic PVC rigid, medium grade conduit with all fixing accessories of 20mm dia and modular sunken box and modular cover plate/frame any module as required and making good to match with the existing surface of wall complete all as specified and directed for One Light/Fan/Bell point controlled by one switch |
| 119 | One Point for socket outlet 5 Amps on independent board complete all as specified and directed. |
| 120 | One Point for socket outlet 5 Amps same board complete all as specified and directed. |
| 121 | Description same all as per item serial No 118 here-in-above but for one socket outlet 16 Amps on independent board with 4.0 Sqmm cable and 4.0 Sqmm earth wire (power point 15 Amps Sockets) complete all as specified and directed. |
| 122 | S&F in repair ceiling rose surface type bakalite 65 x 50mm three terminal complete all as specified and directed. |
| 123 | S&F for modular switch 1 way, 6 Amps, 230 Volts AC, one way complete all as specified and directed. |
| 124 | S&F for modular socket out let 2-in-1, 3 pin, 6 Amps, flush type, 2 module completeall as specified & directed. |
| 125 | S&F for modular switchflush type 16 Amps, 230V AC single pole one waycompleteall as specified & directed. |
| 126 | S&F for modular socket out let 2-in-1, 3 pin, 5 & 16 Amps, flush type, 2 module completeall as specified & directed. |
| 127 | S&F for modular bell push, flush type, 6 Amps, 1 moudle, SP, 230 Volts AC completeall as specified & directed. |
| 128 | S&F for Call Bell, ding dong type AC, 230 Volts, Single Pole complete all as specified & directed. |
| 129 | S&F in replacment, double door metallic sheet metal enclosure for Distribution Board when MCBs to be used TPN 4 ways, 415 Volts with 200 Amps rated bus bar IP 43 - IK 09 complete fixed properly on in concealed position and to provide required sizes of flexible conduit at any open surfaces near DBs of cables/wires complete all as specified and directed., Make - Legrand/L&T/ Scheinder |
| 130 | S&F in replacment, double door metallic sheet metal enclosure for Distribution Board when MCBs to be used SPN 8 ways, 240 Volts with 100 Amps rated bus bar IP 43 - IK 09 complete fixed properly on in concealed position and to provide required sizes of flexible conduit at any open surfaces near DBs of cables/wires complete all as specified and directed., Make - Legrand/L&T/ Scheinder |
| 131 | Supply and fixing in replacment of240V, 10 KA \"B\" curve miniature circuit breaker (MCB) of single poles and current carrying capacity 6 to 32 AMP, in the MCB DB Complete with connection testing and commissioning complete all as specified and directed. Make - Legrand/L&T/ Scheinder |
| 132 | Supply and fixing in replacment of240V, 10 KA \"B\" curve miniature circuit breaker (MCB) of single poles and current carrying capacity 40/63 AMP, in the MCB DB Complete with connection testing and commissioning complete all as specified and directed.. Make - Legrand/L&T/ Scheinder |
| 133 | M&L for earthing complete with galvanised steel earth plate electrode 60 x 60 cm x 3.15 mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to galvanised iron wire 32 x 6mm dia strip asearth lead wire by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in Electrical plate No. 3, MES SSR Part I- 2009 with 15 mm dia medium grade GI pipe as a protection to earthing lead and 20 mm dia medium grade GI pipe for watering purpose including excavation & earth work in any type of soil, funnel, wire mesh, RCC pit with cover, cast iron frame complete and connected to earthing test point all as specified or indicated including testing on completion. Notes(i)The concrete pit shall be PCC (1:3:6) type C-1, 40mm thick precast cover slab of RCC with suitable Mild steel handle in lieu of cast iron cover shown in electrical plate No 3 of MES SSR Part-I(ii) PCC pit shall be provide at least 500 mm away from the earth pit and not on just on the eath pit and extra cost of additional length of water pipes and fittings junction etc shall be deemed to be included in the rate. (iii) Item includes the cost of 7.5 metre earth lead wire andGI pipe for protection of earth wire. Any varriation in quantity shall be adjusted. |
| 134 | Supply and fixing of GI pipe light grade of size 15 mm bore for laying in trenches/floors or walls including allfittings for fixing complete all as specified and directed |
| 135 | M&L for earth continuity conductor or main earthing lead 4 mm dia GI or steel wire fixed to wall on batten or recessed or buried in ground or drawn in conduit/pipe all as required at site complete all as specified and directed |
| 136 | M&L inreplacment oftwo single core (submain) FRLS PVC insulated cable of6.00 Sqmm nominal dia and one single core green PVC insulated copper conductor earth continuity cable of 6.00 sqmm nomianal dia as mentioned below is drawn in and includingnon metallic, medium duty, rigid PVC conduit not less than 20 /25mm dia concealed in wall including all conduit and fixing accessories including cutting chases & making good to disturbed surfaces with cement mortar ratio of 1:4 and colour wash complete all as specified and directed.Note :- (I) The cost for cutting, chases required and suitable lugs shall deemed to be included in the quoted unit rate.(II) Two run of submain wire, one run of earth wire and one run of PVC conduit shall be measured one RM |
| 137 | M&L inreplacment oftwo single core (submain) FRLS PVC insulated cable of4.00 Sqmm nominal dia and one single core green PVC insulated copper conductor earth continuity cable of 4.00 sqmm nomianal dia as mentioned below is drawn in and includingnon metallic, medium duty, rigid PVC conduit not less than 20 /25mm dia concealed in wall including all conduit and fixing accessories including cutting chases & making good to disturbed surfaces with cement mortar ratio of 1:4 and colour wash complete all as specified and directed.Note :- (I) The cost for cutting, chases required and suitable lugs shall deemed to be included in the quoted unit rate.(II) Two run of submain wire, one run of earth wire and one run of PVC conduit shall be measured one RM |
| 138 | Supply and fixing Ceiling Fans complete copper wound with blades, down rods and accessories 230 Volts, 1200mm sweep, minimum air delivery 210 CFM with service value 6.00 BEE, 5 Star rated with brushless direct current motor (BLDC) and old one dismantling/ disconnecting from existing mounting arrangment and deposit to MES store as specified and direced, Make : Bajaj/Havells/Usha |
| 139 | Supply and fixing Exhaust Fan made of sturdy engineering plastic complete with louvers shutter voltage 230 Volts, 50 Hz, RM 1200, Copper winding of sweep 250mm complete all as specified and direced, Make : Bajaj/Havells/Usha |
| 140 | Supply and fixing Exhaust Fan steel body AC single phase, 230 Volts of size 300mm sweep with blades and frame and louvers complete all as specified and direced, Make : Bajaj/Havells/Usha |
| 141 | S&F for LED tube light fittings decorative ultra slim linear fixture with extruded alluminium heat sink environmental friendly energy efficient ready to use pack, 20 Watt, efficiancy 120 Lm/watt, 4 feet, surface mounting type extruded pvc, snap on installers and domestic electronic Driver, connector block ect.with all assoceries intenallt prewired &includingconeecting up with 2 core flexible cppper conductor cable with sutable size & suitable for and mounting clamps all as specified & directed.Make Philips/Wipro/GE Power |
| 142 | Supply & fixing energy efficient LED light of 10 Watt of length - 02 Feet long, wide voltage protection range 140-270 Volt AC housed in extruded aluminum housing (enhances safety) with high quality polycarbonate diffuser including making connection with two core PVC insulated, sheathed copper conductor cable of size 23/0.0076 complete all as specified and directed. Make Philips Cat No. BN170C LED 10 S -6500 PSU L1 120 or equivalent in Wipro/Bajaj as approved by GE. |
| 143 | Supply & fixing energy efficient LED light of 5 Watt, 120 lumen/watt of wise voltage protection range 140-270 Volts AC housed in extruded alluminium housiing (enhances safety) with high quality polycarbonate diffuser incluidng making connection with two core PVC insulated, sheathed copper conductor cable of size 23/0.0076 |
| 144 | S&F energy efficient wall bracket fititng comprising of pin type LED Bulb 5 Watt of wide voltage protection range 230 Volts AC with high quality polycarbonate diffuser incl making connection with 2 core PVC insulated, sheathed copper conductor cable of size 23/0.0076 |
| 145 | Supply & fixing LED Street Light fitting 35 Watt, 120 lumen/watt, 230 Volts AC outdoor type with high pressure die cast aluminium hosing and heat resistent complete with driver, lamp bracket with impact and corrosion resistent including thermal management in multiple optics complete with IP 65/66 protection including bracket for street light made out of 40mm bore GI pipe medium grade not less than 1.2 mtrer length bent at 120 degree to shape fixed on pole/wall with and including 50 x 6mm FI clamps - 02 Nos with nuts, bolts, washers including painting of clamps with two coats of synthetic enamel paint over a coat of red oxide primer |
| 146 | M&L for bracket made out of GI Pipe 40mm dia medium grade. 0.9 mtr long bent to shape with welded MS flat 40 x 6mm for mounting of fitting and MS flat iron clamps made out of 40mm x 6mm thick FI nuts, bolts inlcuding takin gdown old unerviceable complete all as specified and directed. |
| 147 | Removing of excavated material (surplus soil) to a distance not exceeding 50 mtr and depositingat a level not exceeding 1.5 mtr above the starting point complete all as specified and diercted. |
| 148 | M&L for sand cushioning to under ground cables in a layer of 23 cm thick (80 mm thick before laying of cable and 150mm thick after laying of cable, punned thickness shall be measured) in trenches complete all as specified and directed. |
| 149 | Supply and laying of well burnt bricks, sub class \"B\" laid flat in trenches for protection of cable complete all as specified and directed. |
| 150 | Supply, laying, joinint and testing in replacement of cable XLPE (LT) insulated screened PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 25 Sqmm 3.5 core complete all as specified and directed. |
| 151 | Schedule of Credit (MINUS) Rs. 58,542.00 B/F from Serial Page No.[Note : Detailsof items for schedule of credit is given on Srl Page No. _____] This amount shall be automatically deducted to arrive at tendered sum |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail