| 1 | Providing and fixing anodized extruded aluminium partitions with door, windows & ventilators (single or double shutter), part pannelled and part glazed with pre-laminated flat pressed 12mm thick particle board (NOVAPAN, ECOBOARD etc) of approved colour & make. Aluminium sections shall be powder coated with approved colour including aluminium powder coated(50 Microns) frame conforming to IS:1948, IS:1949 fabricated from extruded sections of INDAL / JINDAL or approved equivalent make having minimum 2mm wall thickness as per IS:1285, IS:733 and electro color coating of 15 microns thickness. Glazing shall be clear float glass of 5.5mm thickness of approved make SaintGobin / Modifloat including sanp fit type beading, concealed screws, fixtures (like tower bolts, hold fast, handles both sides, door stoppers with rubber shoes, \"L\"drops, stays, floor springs, hydralic door closers etc) lokcing arrangement for windows, Godrej make mortice lock with 3 no keys for each door, C.P.brass / staineless steel screws, providing and fixing hinges / pivots, and making provisions for fixing of fittings where ever required including cost of PVC / neoprene gasket fits all complete with necessary fillingup of gaps at the junctions, at top, bottom and sides etc., complete.Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically whereverrequired. |
| 2 | Supply and Fixing of EAVES GUTTER (600mm to 1000mm girth) made with 2.00mm thick Galvanized sheets of approved make like Jindal / Tata steel or equivalent make approved by Engineer (size, shape and pitch of corrugation as approved by Engineer incharge matched to existing shape) with Zinc coating 120gsm both sides as per IS:277 in 250mpa steel grade, This shall be fixed using self drilled screws where ever specified by Engineer representative of size 5.5x55 mm with EPDM seal of CORRO SHIELD or equivalent make. The Joints shall be welded and properly sealed with sealing compounds etc., making required holes for connecting rain water pipes. The scope of work also includes removal of existing damaged Eaves Gutter line and useful material hand over to Department and dispose the waste material at specified places complete all as directed by the Engineer Incharge. (Quoted rate shall inclusive of all over laps) |
| 3 | Supply of 150 mm dia GI pipe & funnel , bent to shape,fix in position,weld, by enlarging the existing hole in the gutter and seal with M-seal or any approved epoxy based sealant to the existing eaves gutters complete all as directed. |
| 4 | Detach the existing Work Stations without damaging and re-fixing the same after completion of renovation work complete all as directed. (Item includes the necessary screw fittings etc., shall be arranged by Contractor) |
| 5 | Providing Two(2) coats of white washing with suryacem / Hitech gold to ceiling surfaces after through scrapping, sand papering and cleaning the surface to give even shade etc., complete all as directed. |
| 6 | Apply two coats ofpremium quality arcylic Interior emulsion paint over a one coat of primer, reqired shade to wall surfaces from approved brandsAsian paints (Royal shine), Berger (silky luxury) where ever specified by Engineer including necessary scaffolding etc., complete. (Rate includes scrapping of old surface by mechanically) |
| 7 | Providing two(2) coats of synthetic enamel paint for doors, windows, grills etc., of required colour using approved branded paints like Asian / Berger / Nerolac, after removal of rust using wire brush or sand paper to give an even shade on old work including applying one coat of zinc rich primer complete all as directed |
| 8 | Providing and fixing 12mm thick frameless toughened glass door shutter of approved brand and manufacturer including providing and fixing top and bottom pivot and double acting hydraulic floor spring type fixing arrangement and making nacessary holes etc for fixing required door fittings all complete as specified and directed by the EIC |
| 9 | Cleaning of wall tiles, comods, Wash basins, taps etc., with Acid or its equivalent material complete all as directed (After completion of cleaning matching grouting putty is applied to entire toilet room tiles is in contractor scope) |
| 10 | Providing 15mm thick Polymer modified plaster with CM (1:4) to walls at all heights, lintels, wall surfaces, etc., wherever required etc., including cost of cement (PPC - Ramco, ACC, Ultratech, Nagarjuna & Jypee) and all materials, tools and labour, scaffolding arrangementsand curing all as per specfications and directions of the Engineer. |
| 11 | Supply lay, test and commissioning of 3 ½ x 50 Sqmm PVC armoured Aluminium cable run along with 2 Nos 8 SWG GI wires. (Approved make Universal/ Polycab/ Finolex/Anchor/ Havells or Equivalent.) |
| 12 | Conduit PVC conduit wiring with 3 runs of 1.5 sq.mm FRLSH PVC flexible copper cable for One point controlled by one switch as directed. |
| 13 | Conduit PVC conduit wiring with 3 runs of 2.5 sq.mm FRLSH PVC flexible copper cable for switch sockets as directed. |
| 14 | Conduit PVC conduit wiring with 3 runs of 4 sq.mm FRLSH PVC flexible copper cable for AC units & 16 A Sockets. |
| 15 | Supply, fix, test & commissioning of 6A Switches for the existing old damaged Switch Boards (Makes - Anchor, Cona or Equivalent) |
| 16 | Supply, fix, test & commissioning of 6A Sockets for the existing old damaged Switch Boards (Makes - Anchor, Cona or Equivalent) |
| 17 | Supply, fix, test & commissioning of 3 modular type switch board with 01no. 16A (3+2 pin) modular socket and switch. |
| 18 | Supply, fix, test & commissioning of modular type switch board with 6A (3+2 pin) modular socket and switches for lighting controls. |
| 19 | Supply, fix, test & commissioning of 8 modular type switch board with 03nos. 3pin 5A modular socket with 02nos. switches as directed by engineer in-charge. |
| 20 | Supply, fix, test & Commissioning of 20A DP MCB with enclosure for AC units as directed by engineer in-charge. (Makes -Scheneider/ABB/Legrand/CG or Equivalent) |
| 21 | Supply & fixing of PVC Conduit pipes, 1/2 inch, for electrical wiring as per the directions of engineer in-charge |
| 22 | Supply, fix, test and commissioning of 200W LED Flood lights, White colour with all accessories (Approved make ACE/Philips/ CG/ Havells/Goldmedal/Bajaj or Equivalent) |
| 23 | Supply, fix, test and commissioning of Square shaped, 15 Watt, Dimension-200X200mm, Cutout-185X185mm, ceiling mounted White LED fixture with all accessories (Approved make Wipro/ Bajaj/ philips/ CG/ Havells or Equivalent) |
| 24 | Supply, fix, test and commissioning of Round shaped, 12 Watt ceiling mounted White LED fixture with all accessories (Approved make Wipro/ Bajaj/ philips/ CG/ Havells or Equivalent) |
| 25 | Supply, installation, testing and commissioning of 20W LED tube light (4 ft. length) along with all other connections & accessories rerquired.(Approved make Wipro/ Philips/ CG/ Havells or Equivalent) |
| 26 | Supply, fix, test & commissioning of 1phase, 240V, Exhaust fan as directed by engineer in-charge.(Approved make CG/ Havells/ Bajaj or Equivalent) |
| 27 | Supply, install, test and commissioning of 5 Star rated, inverter type, 1.5T Split AC unit (Cu. Condenser) with Stabilizer, Power cable, Cu Pipe as per site conditions, Stand for Outdoor unit, remote etc. Recommended makes: Bluestar, Voltas, Carrier) |
| 28 | Supply, install, test and commissioning of 5 Star rated, inverter type, 2.0T Split AC unit (Cu. Condenser) with Stabilizer, Power cable, Cu Pipe as per site conditions, Stand for Outdoor unit, remote etc. Recommended makes: Bluestar, Voltas, Carrier) |