Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | EARTH WORK |
| 2 | Earth work in excavation in foundation trenches not exceeding 1.50 m width or 10 Sq.m. on plan or drains not exceeding 1.50 m in width or 10 Sq.m. on plan including dressing of sides and ramming of bottoms, lift upto 1.50 m including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. |
| 3 | a) Ordinary Soil |
| 4 | a) Hard Soil |
| 5 | Extra for every additional lift of 1.50 m or part thereof for earth work in all soils including shingles, small size boulders upto 30 cm size but excluding saturated soil and rock. |
| 6 | Re-filling excavated earth in foundations and plinth etc. in 15 cm layer including ramming and watering etc. complete. |
| 7 | Filling in plinth with sand under floors including watering, ramming, consolidating and dressing complete. |
| 8 | CEMENT CONCRETE |
| 9 | Providing and laying cement concrete 1 : 3 : 6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) excluding the cost of centring and shuttering in :a) Foundations and plinth |
| 10 | b) Walls including attached buttresses, pilasters and their caps and bases and string courses etc. up to floor two level. |
| 11 | Providing and laying in foundations and plinth cement concrete 1 : 4 : 8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size) excluding the cost of centring and shuttering |
| 12 | Centring and shuttering including strutting, propping etc and removal of form work for :b) Walls including attached buttresses, pilasters etc. |
| 13 | RCC WORK |
| 14 | Reinforcement cement concrete work in columns, pillars, piers, abutments, post and struts etc up to floor two level including finishing and plastering the exposed surface with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface but exluding cost of centring, shuttering and reinforcement.a) M20 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size). |
| 15 | Reinforced cement concrete work in lintels, beams and bresumers up to floor two level including finishing and plastering the exposed surface with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface but excluding cost of centering, shuttering and reinforcement.a) M20 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size). |
| 16 | Reinforced cement concrete in suspended floors, roofs, landings and balconies upto floor two level including finishing and plastering the exposed surface with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface but excluding cost of centring and shuttering and reinforcement with M20 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size). |
| 17 | Reinforced cement concrete work in stair cases (excluding landing) except spiral cases including finishing and plastering the exposed surface with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface, preparing of the top surface and finishing, nosing upto floor two level but excluding the cost of centring, shuttering and reinforcement withM20 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size). |
| 18 | Reinforced cement concrete in chajjas exceeding 15mm in thickness upto floor two level including centring and shuttering complete but excluding the cost of reinforcement with M20 1 : 1.5 : 3 (1 cement : 1.5 Coarse Sand : 3 stone aggregate 20 mm nominal size). |
| 19 | Centring and shuttering including strutting, propping etc and removal of form work for : |
| 20 | b) Column, pillars, posts and struts etc. |
| 21 | c) Lintels, beams, girders, bressumers and cantilevers etc. |
| 22 | d) Suspended floors, roofs, landings shelves and their supports, balconies and chajjas (3.5 m height). |
| 23 | e) Stairs (excluding landings) except spiral stair cases. |
| 24 | Reinforcement of RCC work including bending, binding and placing in position complete.b) Tar/TMT steel |
| 25 | BRICK WORK |
| 26 | Brick work with best available local bricks in foundations and plinth in cement mortar 1:6 (1 cement : 6 fine sand). |
| 27 | Extra for brick work with best available local bricks in superstructure above plinth level up to floor two level. |
| 28 | Half brick masonry (with best available local bricks) in cement mortar 1:4 (1 cement : 4 coarse sand) in foundation and plinth. |
| 29 | Extra for half brick masonry in superstructure above plinth level and up to floor two level. |
| 30 | WOOD WORKS |
| 31 | Providing approved best available local wood (Class - B II) work in frames of doors, windows clerestory windows and other frames, wrought framed and fixed in position. |
| 32 | Providing and fixing panelled, glazed or panelled and glazed shutters for doors, windows and clerestory windows including black enamelled MS butt hinges with necessary screws.a) 38mm thick best available local wood class - B I |
| 33 | Providing and fixing best available local wood glazed shutters for doors, windows and clerestory window using 7.5 kg/Sq.m. (3 mm thick glass panes) including black enamelled MS butt hinges with necessary screws.a) 30mm thick |
| 34 | Providing and fixing 40 x 3 mm flat iron hold fasts 40 cm long including fixing to frame with 10 mm dia bolts, nuts and wooden plugs and embedding in cement concrete block 30 x 10 x 15 cm in 1 : 3 : 6 (1 cement : 3 sand : 6 hard stone chips 20 mm nominal size). |
| 35 | Providing and fixing MS grills of required pattern in wooden frames of windows etc with MS flat, square or round bars with round headed bolts and nuts or by screws.a) Plain Grills |
| 36 | Providing and fixing aluminum sliding door bolts anodised transparent or dyed to required color or shade with nuts and screws etc complete.a) 250 X 16 |
| 37 | Providing and fixing aluminum Tower bolts anodized or transparent or dyed to required color or shade with necessaryscrews etc complete. |
| 38 | a) 250 x 10 mm |
| 39 | b) 150 x 10 mm |
| 40 | Providing and fixing aluminum Handles anodised transparent or dyed to required color or shade with necessary screws etc complete. |
| 41 | a) 125 mm |
| 42 | b) 100 mm |
| 43 | Providing and fixing MS Hooks and Eyes.a) 200 mm |
| 44 | STEEL WORK |
| 45 | Steel work riveted or bolted in built up sections, trusses and framed work including cutting, hoisting, fixing in position and applying a priming coat of red lead paint.b) In Tees, Angles, Flats and Channels |
| 46 | Providing and fixing MS fan clamp type I of 16 mm dia MS bar bent to shape with hooked ends in RCC slabs during lying including painting the exposed portion of loop all as per standard design complete. |
| 47 | Providing and fixing stainless steel (Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.). |
| 48 | ROOFING |
| 49 | Providing and fixing Durashine zinc-Aluminium alloy coated (TATA Bluescope building product) sheet roofing fixed with necessary fasteners and lapping method as described by the manufacturer inclusive of cutting hoisting and fixing complete, excluding the cost of purlins, rafters and trusses.a) Total coated thickness 0.45mm Roofing Sheets |
| 50 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes.b) 110mm diameter |
| 51 | FLOORING |
| 52 | VITRIFIED TILES FLOORING |
| 53 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and confiorming to IS : 15622 of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1cement:4 coarse sand), including grouting the joints with white cement and matching pigments etc.., complete.b) Size of Tile 600x600 mm |
| 54 | VITRIFIED TILES SKIRTING |
| 55 | Providing and laying vitrifiedtiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and confiorming to IS : 15622 of approved make, in all colours and shades, in skirting, riser of steps, over 12mm thick bed ofcement mortar 1:3 (1cement : 3 coarse sand), including grouting the joints with white cement and matching pigments etc.., complete.b) Size of Tile 600x600 mm |
| 56 | Chequered terrazzo tiles 22 mm thick with marble chips of sizes upto 6mm in floors on 25 mm thick bed mortar 1 : 3 (1 cement : 3 coarse sand) jointed with neat cement slurry mixed with pigment to match the shade of the tiles including rubbing and polishing complete:a) Light shades using white cement |
| 57 | FINISHING |
| 58 | : CEMENT PLASTER : |
| 59 | 12 mm cement plaster 1 : 4 (1 cement :fine sand). |
| 60 | 15 mm cement plaster 1 : 6 (1 cement : 6 fine sand) on the rough side of single or half brick wall. |
| 61 | Neat cement punning. |
| 62 | : PAINTING : |
| 63 | Providing two coats of acrylic based wall putty/ wall filler of Asian Paits/ Berger/ Dulux over concrete/ cement plaster/ brick walls and ceilings both internal and external after removing allMthe loosely adhering material from the wall/ ceiling surface with the halp of emery stone, putty blade or wire brush, moistening the wall with the help of sufficient quantity of clear water as specified and directed by the department. |
| 64 | Wall painting (two or coats) with plastic emulsion paint of approved brand and manufacture on new work to give an even shade. |
| 65 | Interior Walls : Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface : |
| 66 | Interior Walls : Finishing walls with water proofing cement paint of required shade :a) New work (Two or more coats applied @ 3.84 kg/10 sqm) |
| 67 | Applying priming coat with ready mixed pink primer of approved brand and manufacture on wood work complete. |
| 68 | Painting two or more coats (excluding priming coat) with superior ready mixed paint for wood work of approved brand and manufacture in all shades on new work to give an even shade. |
| 69 | Applying priming coat with ready mixed primer of approved brand and manufacture on steel work. |
| 70 | Painting two or more coats (excluding priming coat) with superior ready mixed paint for steel work of approved brand and manufacture in all shades on new work to give an even shade. |
| 71 | MISCELLANEOUS |
| 72 | Making plinth protection 50 mm thick of cement concrete 1 : 3 : 6 (1 cement : 3 coarse sand : 6 stone aggregate using 20 mm nominal size) over 75 mm bed of stone ballast 40 mm nominal size well rammed and consolidated and grouted with fine sand including finsihing the top smooth. |
| 73 | Providing and fixing 40 mm dia GI Pipe outlet in cement mortar 1 : 3 (1 cement : 3 fine sand) including cutting and making good the wall. |
| 74 | DRAINAGE |
| 75 | Construction of cement concrete drain 30 cm wide and 23 cm deep in cement concrete 1 : 3 : 6 (1 cement : 3 sand : 6 hard graded stone chips/shingle 40 mm and down gauge) 8 cm thick on sides and bottom and plastering on all exposed surfaces with 12 mm thick cement mortar1 : 3 (1 cement : 3 fine sand) including shuttering complete. |
| 76 | Constructing brick masonry manhole with 2nd class bricks in cement mortar 1 : 5 (1 cement :5 fine sand) RCC top slab with 1 : 2 : 4 mix (1 cement : 2 coarse sand : 4 stone single 20 mm nominal size), foundation concrete 1 : 4 : 8 mix (1 cement : 4 coarse sand : 8 stone aggregate 40 mm nominal size) inside plastering 12 mm thick with cement mortar 1 : 3 (1 cement : 3 coarse sand) finished with a floating coat of neat cement and making channels in cement concrete 1 : 2 : 4 mix (1 cement : 2 coarse sand : 4 stone aggregate 20 mm nominal size) neatly finished complete as per standard design.a) Inside size 90 x 80 cm and 45 cm deep including CI cover with frame (light duty) 455 x 610 mm internal dimensions total weight of cover and frame to be not less than 38 Kg (weight of cover and frame to be not less than 38 kg, (weight of cover 23 Kg and weight of frame 15 Kg). |
| 77 | Making soak pit 2.50 m dia 3 m deep with 45 x 45 cm dry brick honeycomb shaft and SW drain pipe 100 mmdia 1.80 m long complete as per standard design. |
| 78 | WATER SUPPLY |
| 79 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge.a) Concealed work, including cutting chases and making good the walls etc.ii) 20 mm nominal outer dia Pipes |
| 80 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.a) External work.iii) 25 mm nominal outer dia Pipes |
| 81 | Providing and fixing C.P. brass long nose bib cock of approved quality conforming to IS standards and weighing not less than 810 gms.b) 15mm nominal bore |
| 82 | Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931.a)15mm nominal bore |
| 83 | Providing and fixing PVC connection pipe with brass union.A) 30 cm lengtha) 15 mm nominal bore |
| 84 | SANITARY |
| 85 | Providing and fixing white vitreous china water closet squating pan (Indian type WC pan) size 580 mm with 100 mm and sand cast iron P or S trap, 12.5 Litre high level CI flushing cistern (of approved make) with fittings RS or CI brackets, 32 mm dia galvanized steel telescopic flush pipe with fittings and clamps 20 mm GI over flow pipe with specials and mosquito proof coupling of approved municipal design and GI chain and pull complete including painting of cistern and fittings, cutting and making good the walls and floors where required.a) Long Pattern WC Pan |
| 86 | Providing and fixing white vitreous china type water closet pedestal (European type WC pan) with seat and lid CP brass hinges and rubber buffers, 12.5 Litres high level CI flushing cistern with fittings RS or CI brackets, galvanized steel telescopic flush pipe with fittings and clamps, 20 GI overflow pipe with specials and mosquito proof coupling of approved municipal design and GI chain and pull complete including painting of cistern and fittings, cutting making good the walls and floors where required.a) WC pan with white plastic seat and lid. |
| 87 | Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x430x265 mm sizes respectively with CI automatic flushing cistern with fittings, RS or CI brackets standard size galvanized steel flush pipe and spreaders with brass unions and GI clamps complete including painting of cistern and fittings, cutting and making good the walls and floors where required.a) One urinal basin with 5 Litres CI automatic flushing cistern |
| 88 | Providing and fixing white vitreous china wash basin with RS or CI brackets painted white 15 mm CP brass pillar taps and CP brass chain with rubber plug 32 mm CP brass waste of standard pattern, 32 mm dia CP brass trap and MI unions complete, including cutting and making good the walls where required. |
| 89 | Providing and fixing kitchen sink including making all connection excluding cost of fittings.a) White glazed fire clay sink size 600x450x150 mm |
| 90 | : TOILET REQUISITES : |
| 91 | Providing and fixing 600x450 mm bevelled edge mirror or superior glass (of approved quality) complete with 6 mm thick asbestos sheet ground fixed to wooden cleadt with CP brass screws and washers. |
| 92 | Providing and fixing sand cast iron/ cast iron (spun) soil, waste and vent pipes.a)100mm dia |
| 93 | Providing and fixing sand cast iron hel rest sanitary bend |
| 94 | a) 100 mm dia |
| 95 | b) 75 mm dia |
| 96 | Providing and fixing sand cast iron single equal plain junction of required degree with access door, insertion rubber washer 3 mm thick, bolts and nuts complete.a) 100 x 100 x 100 mm |
| 97 | Providing and fixing sand cast iron trap of self cleadnsing design with sand cast iron screwed down or hinged grating with or without vent arm complete including cost of cutting and making good the walls and floors.(b) 100 mm inlet and 100 mm outlet |
| 98 | STAGE CRAFTING, STAGE LIGHTING, AUDI CHAIRS |
| 99 | Stage Procenium Arc \"Structure In Front of Stage\"The proscenium of a stage is one of the divisions of the stage,As per Architectural Drawings, Work will be executed as per the instructions of Engineer-in-charge (EIC) including all tools, tackles, machineries, manpower, staging, any consumables, etc. complete.A structure infrontofthestagethatframestheactionoftheplay. It can be square or arched, and the stage curtain is generally directly behind it.\"Picture frame\" placed around the front of an end stage. the invisible barrier that separates the stage from the audience and through which the audience watches the action. The “Arch acts like a picture frame through which the action can be seen. The picture above shows the Proscenium Arch of the Stage. A proscenium arch creates a \"window\" around the scenery and performers, the advantages are that it gives everyone in the audience a good view because the performers need only focus on one direction rather than continually moving around the stage to give a good view from all sides. A proscenium theatre layout also simplifies the hiding and obscuring of objects from the audience\"s view. Anything that is not meant to be seen is simply placed outside the \"window\" created by the proscenium arch, either in the wings or in the fly space above the stage. Arch serves as the frame into which the audience observes from a more or less unified angle the events taking place upon the stage during a theatrical performance.Providing & fixing Stage Proescinium: to be fabricated on site as per proposed design Outer MS tubler framemade with 50mm X 50mm and inner Joints with 25mm X 25mm infill with 48mm thick 40kg/cum density Rockwool insulation padding. front side fixing on 12mm Water Proof Ply. |
| 100 | Horizontal MAIN CURTAIN:As per Architectural Drawings, Work will be executed as per theinstructions of Engineer-in-charge (EIC) including all tools, tackles,machineries, manpower, staging, any consumables, etc. completeThe complete automatically motorized Stage curtain systemwith additional modifiedGearbox fitted with sealed bearings self-lubricating centresplitoverlappedcurtainsboth sidesopeningfullyautomaticStage Curtainfixingsteelrailstrack made out of 450 GSM made out of, doublegathering Velvet, Molfin, Mokel or Hitech Fabric Curtain cloth draperyhorizontal sliding arrangement completewith fixing rails, brackets and motorized operation completewith runners, master runners, pullies, 3mmsteel wire rope, 1HP Motor (Crompton or Godrej) 2Nos Air Breaker Contractors (L&T/SIEMENS), 2nos. Micro Switches for auto stop, 3 nos push buttons for forward. All rollers are sliding with roller clamp, The curtain should be half of full width operated from controlpanel with control switches. Provision is for fully automatic operationonly.Height 24\"-0\" , Length 46\"-6\" ( Area =1116Sq.Ft.)“Decorative fancy gota embroidered three layer golden border gota Patti on bottom of front Curtain”FABRIC SPECIFICATION : 450 GSM VELVET, Shade and fabricapproved by Engineer in Charge or enduser Fabric Make : Innovative, Response or Nexgen Specified Make: Canara /Stage Works / Illumitex |
| 101 | Horizontal REAR CURTAIN:As per Architectural Drawings, Work will be executed as per theinstructions of Engineer-in-charge (EIC) including all tools, tackles,machineries, manpower, staging, any consumables, etc. completeThe complete automatically motorized Stage curtain systemwith additional modifiedGearbox fitted with sealed bearings self-lubricating centresplitoverlappedcurtainsboth sidesopeningfullyautomaticStage Curtainfixingsteelrailstrack made out of 450 GSM made out of, doublegathering Velvet, Molfin, Mokel or Hitech Fabric Curtain cloth draperyhorizontal sliding arrangement completewith fixing rails, brackets and motorized operation completewith runners, master runners, pullies, 3mmsteel wire rope, 1HP Motor (Crompton or Godrej) 2Nos Air Breaker Contractors (L&T/SIEMENS), 2nos. Micro Switches for auto stop, 3 nos push buttons for forward. All rollers are sliding with roller clamp, The curtain should be half of full width operated from controlpanel with control switches. Provision is for fully automatic operation only.Height 24\"-0\" , Length 46\"-6\" ( Area =1116Sq.Ft.)FABRIC SPECIFICATION : 450 GSM VELVET, Shade and fabricapprovedbyEngineer inChargeor enduser FabricMake:Innovative,Responseor Nexgen Specified Make:Canara / Stage Works / Illumitex |
| 102 | STAGE FRILLS:As per Architectural Drawings, Work will be executed as per theinstructions of Engineer-in-charge (EIC) including all tools, tackles,machineries, manpower, staging, any consumables, etc. completemade out of, 450 GSM double gathering glazed Velvet, Molfin, Mokel or Hitech Fabric; to be installed above the stage on 28mm dia GI pipeadjustable at position according to stage positioning plan; Cloth materialof desired shade with Stitching.FABRIC SPECIFICATION : 450 GSM VELVET, Shade and fabricapproved by Engineer in Charge or enduser Fabric Make : Innovative, Response or Nexgen Specified Make: Canara / Stage Works / Illumitex |
| 103 | STAGE WINGS:AsperArchitectural Drawings, Work willbeexecutedaspertheinstructions ofEngineer-in-charge(EIC) includingalltools,tackles,machineries, manpower, staging, any consumables, etc. completeProviding and fixing of cloth wings made out of black glazed 450 GSM Velvet, Molfin, Mokel or Hitech fabric fixed on 32mmPivoted Rotatable BarFixedwiththickcommercialplywoodfixedononesideofFrameworkwithslidingassembly ontopsupported fromecistingstructure&wheels on bottom for free movement.FABRIC SPECIFICATION : 450 GSM VELVET, Shade and fabricapproved by Engineer in Charge or enduser Fabric Make : Innovative, Response or Nexgen Specified Make: Canara / Stage Works / Illumitex |
| 104 | GRID STRUCTURE:AsperArchitectural Drawings, Work willbeexecutedaspertheinstructions ofEngineer-in-charge(EIC) includingalltools,tackles,machineries, manpower, staging, any consumables, etc. complete Customized Fabrication of Main Overhead Grid over Stage using 50mm x 50mm x 5mm MS A Iron, in a 2ft.x2ft. Section & suspended from theceiling “37ft X 25ft “ Grid dimension. |
| 105 | Cable Trays:As per Architectural Drawings, Work will be executed as per theinstructions of Engineer-in-charge (EIC) including all tools, tackles,machineries, manpower, staging, any consumables, etc. complete Cabletraysofsize4”x2”-16 gaugesheetCRC,for wiringof stage lights & soundsystem and enrooted to control room.Specified Make: Canara / Stage Works / Illumitex |
| 106 | Fabrication on Stage & CatwalkAs per Architectural Drawings, Work will be executed as per theinstructions of Engineer-in-charge (EIC) including all tools, tackles, machineries, manpower, staging, any consumables, etc. complete for holding entire fixtures, lights, wings, light bar and other accessories, made from40X40X6mm angle with wire mash1” square 3ftwidth withflat & angle ironSpecified Make: Canara / Stage Works / Illumitex |
| 107 | Supply, Installation, Laying, Testing & Commissioning of Data Signal Cabling for Remoter Curtains:As per Architectural Drawings, Work will be executed as per theinstructions of Engineer-in-charge (EIC) including all tools, tackles,machineries, manpower, staging, any consumables, etc. completeUsing 4-core PVC insulated multistranded cable to transmit Signal through curtain drives . high speed data cable designed for EIA485 ;lowcapacitance, twisted pair shielded ; FHDPE insulation, for interlinkingsplitter to Control Room with required connectors (1 main +1 backup) |
| 108 | MODULAR WIRED FIXED HEAVY-DUTY STAGE LIGHTING BAR SYSTEM MAKES RIGGING LIGHTS QUICK AND EASYWITHPOWER OUTLETS BUILT INTO THE BAR FOR LIGHTING APPLICATIONS.:Over Head Light Bar fabricated with Steel Rectangular Tube 4\" x 4\" x 16Gauge dia pipe of full length interlocked with 2\"inch square pipe lincked with 2\"inch round pipe for trussing with adequate clamps, bars can be linked together side by side to form a single rigid bar, bar can be hungfrom wire ropes, chains or hung from an existing grid, this lighting bar painted in side, outside with zinc chromate primer finally coated with black quick drying enamel paint to mounting for stage lighting, which is suspended from bars above the stage to focus/Wash the stage.Approved Brands: Canara/ Stage Works/ Illumitex/ Effectron |
| 109 | Truss FOH “FRONT OF HOUSE” LIGHT BAR:40NBdiapipeof full length trussingwithadequateclamps,thislighting bar paintedin side, outsidewith zinc chromate primer finally coated withblack quick drying enamel paint required which is suspended from ceilingin front of stage to focus stage. 36ft Length.Approved Brands: Canara/ Stage Works/ Illumitex/ Effectron |
| 110 | Side Ladder: P/f of the side ladders made out of 50x25mm MS tube pipesize: 4x2 ft.. Approved Brands: Canara/ Stage Works/ Illumitex/ Effectron |
| 111 | 350w17R super beam moving head light double prisms(rainbow effects), glass gobos. oltage, AC100-240V 50/60HzPower consumption: 500WLight Source: PHILIPS 350W lampBallast: Electronic Ballast Channels: OMX 18/22 ChannelsColor wheel: One color wheel, 13 colors + open Gobo wheel: One static gobo wheel, 13 gobos+ open Prism: Two rotating prism,One 16-facet prism and one 32-facet prismFrost: Gradually frost, wash angle 5-30 degree Strobe: 0.5-14/c variablestrobe effectLens:Glassopticlens,linearzoom0-20degreeMovement:Pan540degree, 8/16 bit resolution Tilt 270 degree, 8/16 bit resolutionPan/Tilt movement auto repositioning function.Auto reset when mis-positioned. Three motor makes movement quicker, smoother and more mute.IP Grade: IP20 Approved Brands: Canara/ Stage Works/ Illumitex/ Effectron |
| 112 | 54X3W As per Architectural Drawings, Work will be executed as per the instructions of Engineer-in-charge (EIC) including all tools, tackles,machineries, manpower, staging, any consumables, etc. complete as per Architectural Drawings, Work will be executed as per the instructions of Engineer-in-charge (EIC) including all tools, tackles, machineries, manpower, staging, any consumables, etc. complete..: Indoor RGBW slim LED Par, Aluminum Die CastApproved Brands: Canara/ Stage Works/ Illumitex/ Effectron |
| 113 | 200w COB Par LED with barndoor1x200W warm white+white 2in1/warm white/whiteVoltage: AC110- 220V, 50-60HZ Power: 100W/200WLight source: 100W COB/200W COBColor: warm white, white Dimming: 0- 100%Control mode: voice, master and slave,self-propelled, DMX512 Channels: 4 / SCHWorking temperature: -30 \"C -40 \"C+RGBApproved Brands: Canara/ Stage Works/ Illumitex/ Effectron |
| 114 | 200W cob led studio par light with zoom Input Voltage: AC100-240V, 50-60HzPower Consumption: 250WLEDQuantity:1PCS200Wcoolwhiteorwarm whiteLEDsColor Rendering Index: (CRI) Ra>90Zoom angle:10 ° to 90 °ControlSignal:DMX512,master-slave,sound,automodeControlChannelsApproved Brands: Canara/ Stage Works/ Illumitex/ Effectron |
| 115 | 4 eyes cob led blinder light 100WVoltage / frequency: AC100V-240V/50-60Hz.Rated power: 430W.Light source: 4 ultra-high brightness COB 1 DOW two-in-one LED.Lamp life: about 50,000 hours.Color: Warm white or white or 2-in-1.Color temperature: 3200K - 5600K can be adjusted. Control channel: 8channels. Light angle: 35° .Dimming: 0-100% linear electronic dimming.Strobe:Independenthigh-speedelectronic strobe,1-13timespersecond.Operating mode: voice control, self-propelled, master-slave, DMX512.Color rendering index: Ra>85 Waterproof rating: IP20Approved Brands: Canara/ Stage Works/ Illumitex/ Effectron |
| 116 | 200w fresnel light with barndoorInput voltage: AC100-240V, 50/60Hz Power: 220WLight source:100W/150W/200W high indicates COB LED lamp.Color rendering index: Ra>95 Light source life: 100000 hoursColor temperature: 3200K, 5600K optional.Control panel: LCD liquid crystal display + four buttons Beam angle: 15 -60 degrees Manual zoom Dimming: 0-100% linear dimming. Cooling method: copper radiator. Channelmode: 1 CH/2CH.Control mode: DMX512 control/manual control.Protection level: IP20 Working temperature: -25° C- +45° CShell Material: Aluminum Alloy Accessories : Concealer, power cord, signal cable Approved Brands: Canara/ Stage Works/ Illumitex/ LBT |
| 117 | 200W LED profilsInput Voltage: AC100-240V, 50/60HzPower Consumption: 260W LED POWER: 200WLED Quantity; 1 PCS 200W white or warm white LEDColor Temperature: 3200K or 5700K color temperature Color Rendering Index: (CRI) Ra>90 Beam Angle: 19° (26° /36° also available)ControlSignal:DMX512,master-slave.automode Control Channel:1/3CH DMX512 channel Product Dimensions: 550•270•185mApproved Brands: Canara/ Stage Works/ Illumitex/ LBT |
| 118 | LED54/72/108/120Pcs Non-waterproof FloodLightRated power: 250WLight source: 54/72/108/120 high brightness and high power 3W LED.Lamp life: about 50,000 hours.Color:RGBWcolormixing,brightcolors,richcolorsandbright,cancombine 16,777,216 color changes. Dimming: 0-100% linear dimming. Control channel: 6CH.Beam angle:15, 25 degrees optional.Controlmode:DMX512,master-slavecontrol,self-propelled,voicecontrol. Protection level: IP20.Approved Brands: Canara/ Stage Works/ Illumitex/ LBT |
| 119 | Splitter 8 channel4/8 independent amplification driver output.The signal amplifying and shaping !unction, extending the signal transmission distance.To enhancethe capacity of data bus access equip men! number. To protect the lighting console DMX512 output interface.fault isolation, improve thesafety and reliability of digital lightingApproved Brands: Canara/ Stage Works/ Illumitex/ LBT |
| 120 | Mini pearl 1024 lighting controller with flight case1.Audio signal input2.MIDI input or output3.Via RS 232System interfaceDMX 512 signal 1024 channel Power supply: 25 V.DC 0.5AApproved Brands: Canara/ Stage Works/ Illumitex/ LBT |
| 121 | 3000W DMX Fog MachineVoltage: AC 110 / 230V 50-60Hz ± 10% Power: 3000WWarm-up time: 12 minutes Smoke oil capacity: 10 liters; Spray distance: 20 meters Smoke cover:40000cu.ff / minControl mode: timing quantitative / DMX512 controlApproved Brands: Canara/ Stage Works/ Illumitex/ LBT |
| 122 | DJ Power Fog oil (5L)applicable to any mode smoke/fog machine by any factory new plasma formula no static elec.no fire crystallization harmless to body and equiplastingfragrance |
| 123 | DMX 3-Pin Male XLR– 3-Pin FemaleXLR DMX Cable:Supply,Installation,Laying,Testing&CommissioningofDMXDataSignalPointWiring:Using2-corePVCinsulated 22AWG multi-stranded Cu.Cond.highspeeddatacabledesignedfor EIA485;lowcapacitance, twistedpair shielded; FHDPE insulation- starting fromDMX Splitter to each Light Bar - either sides, SideLadders and Floor Points, as required to be terminated with suitable XLRconnectorsApproved Brands: NUTRIK, SUNRISE or LOSEN |
| 124 | LIGHTING SAFETY HOOKFeaturesChoose from multiple lengths and safety bond typesGalvanised steel cable Black PVC coatedBlack steel cableScrew-gate carbine hookShackleDesigned and manufactured in the UK!Specifications Cable diameter: 3mmWorking Load Limit (WLL): 25kg |
| 125 | Black Steel Hook:G CLAMPStrongmetalGclampfittedwithprotectorstripdesignedforhanginglight effects. Fits on bars up to 50mm diameter. |
| 126 | Supply, Installation, Testing & Commissioning of Wiring for Direct Points Using PVC Insulated Finolex 1.5 sqmm 3Core FRLS Cu.Cond. cable for2 sockets/box ; 30 No. Core FRLS Cu.Cond. cable for 2 sockets/box ; starting from the supplied MCB Box/Panel, having 10A SP MCBs, to the Lighting bars/tree or stage points ; terminated at junction box with 2 x SHUCKO 16 Amp. Sockets/per point (all points to be marked &numbered) |
| 127 | Supply of Step light 4 ft - warm white Up and Down throw Along with 6compatable Power supply 20 AMPS, 22 lights can be operated throughone powersuppy |
| 128 | Exit Signage for Doors |
| 129 | SITC of Push Back Auditorium Chair:As per Architectural Drawings, Work will be executed as per theinstructions of Engineer-in-charge (EIC) including all tools, tackles,machineries, manpower, staging, any consumables, etcPUSH BACK CHAIRS is an optimally designed chai for use in and auditoriums Epoxypowered coatedpaint for all steel parts.• 25mm x5mm MSflatmadebackinnerframewith3serpentinesprings.•PPCP plastic molded one-piece inner seat frame Molded polyurethanefoams cushioned seat back.•Upholsterswithflameretardantfabric(Optionscotch guardforstainresistance)• Zipper attached to seat back fabric for easy resolvability• Epoxy powered coated paint for all steel parts• Integrated skin type PU foam made arm rest with or without cup holder•Maintenance free synchronized push back system, with seamless seat supporting tray• Heavy gauge CRC sheet made side stand covered with fabric 4.5kg• Back side of the back covered with PPCP plastics back coverChairs installed to the floor with expended anchor fasteners Approved Brands: CINEMA WORKS / INNOVATIVE / WIPRO |
| 130 | ACOUSTIC TREATMENT, INETRIOR & AUDI CARPET |
| 131 | CEILING TREATMENTProviding & Fixing of (Moisture Resistant Gypsum board Ceiling) All height with necessary GI framing as explained under Gypsum ceiling.As per Architectural Drawings, Work will be executed as per theinstructions of Engineer-in-charge (EIC) including all tools, tackles,machineries, manpower, staging, any consumables, etc.Features & Properties:• Good sound insulation performance• Hydrophobic boards impregnated against absorption of moisture• High fire protection performance•Containsglassfibreadditivestomaintaintheintegrityofboardforlonger time periods than standard boards when exposed to fire.•Amaterialthatbreathesandbalancesroomclimateandhumiditylevels• Environment friendly• Limitless design optionsThe taperedand squareedgesof theboardsare jointed andfinished to a flushfinish withrequisite jointing compound paper tapes finishes and primer suitable for gypsumplaster boardsasper mentionedmakewith12.5mm thickness. including two or more coats of plastic emulsion paintto a smooth finish finished surface area of Gypsum board Ceiling. with cove desigen. Work complete in all respect as per the drawing& design to the satisfaction of Engineer in-charge or Project Officer.Approved Brands: USG BORAL(Lafarge) / Saint Gobain / (Gypcore)/Indain Gupsum |
| 132 | Providing & Fixing of Mineral Fibre Acoustical Suspended Ceiling System) All height with necessary GI framing As per Architectural Drawings, work will be executed as per the instructions of Engineer-in-charge (EIC) including all tools, tackles,machineries, manpower, staging, any consumables, etc.Features & Properties:Providing&Fixingof MineralFibreAcousticalSuspendedCeiling Systemwithtileswith15mmExposedGRIDasper manufacturer specification. The tiles should have Humidity Resistance (RH) of 95%, NRC 0.9, Light Reflectance ≥85%, Fire Performance UK Class 0 / Class1 (BS 476 pt - 6 &7) in module size of 600 x 600 x 15mm. The tile shall be laid on38 15 mm wide T - section flanges colour white having rotary stitching on all T sections i.e. the Main Runner, 1200 mm & 600 mmCross Tees with a web height of 38mm and a load carrying capacity of14 Kgs/M2. The T Sections have a Galvanizing of 90 grams per M2.INSTALLATION: To comprise main runner spaced at 1200mm centres securely fixed to the structural soffit using suspension system (as per specifications) at 1200mm centre to centre. The First/Lastsuspensionsystem at the end of each main runner should not be greater than 450mm from the adjacent wall. Flush fitting 1200mm long cross tees tobe interlocked between main runners at 600mm centre to form 1200 x600 mm module.Cut cross tees longer than 600mm requireindependent support.600 x 600mm module to be formed by fitting 600mmlongflush fittingcrosstees centrally between the1200 mm cross tees. Perimeter trim to be wall angles of size 3000x19x19mm, secured towallsat 450 mmmaximumcentres.SUSPENSION SYSTEM |
| 133 | SIDE WALLS TREATMENTWooden Grooved & perforated Acoustical Panels Used On Auditorium Side WallsProviding&fixingofcustomizedgrooved&perforatedwoodenMediumDensityFibreboardpaneltoreduceechoesby trapping and diffractingsound in the grooves and perforation found on the surface backing with black fleece.As per Architectural Drawings, Work will be executed as per theinstructions of Engineer-in-charge (EIC) including all tools, tackles, machineries,manpower, staging,anyconsumables,etc.completeto achiveNRC 0.76 (NoiseReductionCo- efficient) with50mmRockwool, The sound that passes through theperforation is further absorbedby Rockwool, whic h reduces reverberation in the room. Smaller grooves arebetter at attenuating high frequency sounds, whereas larger grooves are better at controlling low frequency sounds with requirted lineal perforation on side wall as per simulated drawings& designs. The panels shall beNon FR grade with melamine laminate panels 2440mmx130mm x18mm with 2.5mm groove at 14mm pitch, Tongue and Groove edges forseamless mounting having density of 400kg/m3, The Panel is fixed by using GI Framework spaced at 600mm centres @ 12 mm wooden ply strips framework spaced at 400mm centers with suitable hardwareand the systemisbacklinewith50 mminsulation andalongwithall accessories.Continue installing rowsof panels by inserting screw & plugs into the groove of the wooden panel and progressively installing the panel into the next keel till the actual height is achieved. Finish offtheedgesusingwoodenmouldingofmatchingcolour.Thepanelling |
| 134 | Stretch Fabric Acoustical Wall System Used On Auditorium Side Walls ProvidingandFixingofFabricacoustic wall andceilingtreatmentsystemasperarchitecturaldrawingstoachivecustomizeddesign,Stretch fabric panelsa are designed for acoustic performance and visual enhancements,Panles combines beauty andfunctionality,creating environmentsthatappealtoallsenses.Inadditiontoeliminatingunwanted noise and reverberation inside Auditorium above 8ft height:As per Architectural Drawings, Work will be executed as per theinstructions of Engineer-in-charge (EIC) including all tools, tackles, machineries,manpower,staging,anyconsumables,etc.completeStretchfabricpanelsfixedonflexibletrack profiles secure and frame fabric finish with excellent for sound control applications and is also a beautifulwall covering, enhancing the décor and the sound ofinstallations, almost any panel size can be created in side Auditorium onG.I studs 2400mm X 50mmweb flanges15 & 50mm fully knurled giving it high strength, hot dipped galvanized steel with 120GSM zinc coatingspecially designed for Acoustic vibration management and long life with a backing 50mm thick Rock wool @48kg density insulation intact withchicken messwires NRC up to .90. To be mechanically fastened on theG.I Studs. Then 12mm Vinyl tracks are screw fixed on to the 12 mm Ply and Acoustics panel’s .Then the fabric is stretched over the Vinyl tracks.The installed system should provide NRC OF 1.00.Fabric colour as perArchitect choice-Ref attached specifications for more details. The systemto be installed onG.I studs 600x600mmcentre to centre 2400mmX 50mmweb thickness 0.5mm, flanges 15 & 50mm fully knurled giving it high strength, hot dipped galvanized steel with 120GSM |
| 135 | Wooden Fire Cum Acoustical Sound Reducing DoorsProviding & fixing Acoustical sound reducing Doors with compatable Wooden Door Frame made of hard wood of section 150 x 90 mm withAcoustic strip of section 10 x 4 mm completely finished with two coat of Primer.AsperArchitectural Drawings, Work willbeexecutedaspertheinstructions ofEngineer-in-charge(EIC) includingalltools,tackles,machineries, manpower, staging, any consumables, etc. complete75mmthickasbestos freecompositefirecumsmokecheckwoodenshutter of 38db acoustic cum 120 min fire resistant rating confirming to BS:476 part-22 & IS:3614 part-2comprising of two 12mm thicknoncombustibleboards,a100%without asbestos,bruciteandmeerschaum,havingdensitynotlessthen1150Kg/M3andthermalconductive 0.14W/m*ksandwiching33 mmthickfire resistanceinsulation filler and faced with 4 mm commercial on both side with heatactivatedintumescentfireseal stripofsize10X4mmmountedin thegrooves of hardwood lipping on all three sides except bottom.a) Finished with 1 mm Thick Laminate.b) Finished with 4 mm Thick Veenear.c) Finished with 2 Coat of Fire Retardant Primer |
| 136 | Providing and fixing of nylon six printed carpet of make approved by Engineer-in-charge including fixing to the floor with adhesive of approved make carpet conforming to following specification complete.Description :- 6 color mix nylon printed carpet. Structre:- Tufted cut pile. composition 100% nylon and fire retardant. Gauge:-1/8. No. of knots per sqm:-1,40,000.00. Secondary backing:- Action back latex. width:-4 metre. Role langth:-25 metre. Pile height:-10mm (+ -)5%. Total thickness:-11 to 12mm. Pile weight:-1000gm/SQM. Total carpet weight 1900gm/Sqm (+ -)5%. Use: commercial. Fire classification: - FF-270. Thermal Resistance:- PASS. Light fastness :- <3. Sound insulation:- 25DB. Coloretion:- Chrome jet printing. including cartage, Under layer PU(Poly urethane) sheet 8mm thick and density of 18-20Kg/m3 to enhance the cushioning of carpet as directed by Engineer-in-charge. |
| 137 | Providing and fixing of 25-50 mm thick wooden nosing made out of 2ndclass teak to finish staircases and edges in flush or overlap.As per Architectural Drawings, Work will be executed as per theinstructions of Engineer-in-charge (EIC) including all tools, tackles,machineries, manpower, staging, any consumables, etc. completeThey are designed to take the brunt of foot traffic while maintaining each step’s beauty. Flush noses are used through glue/ nail-down methods.They are often nailed with shoe, saddle & Quarter roundshape leavingsmooth and finshed surface, They often contribute to low maintainance and extended life span of the material keeping the edges safe and in alignment. |
| 138 | Providing and Fixing of Side Skirting Wooden Beading As per Architectural Drawings, Work will be executed as per the instructions of Engineer-in-charge (EIC) including all tools, tackles,machineries, manpower, staging, any consumables, etc. complete Installation on side skirting & Molding 100mmX10/8mm as per requriedfinnishing with melamine polishing. Work complete in all respect as per the drawing to the satisfaction of Engineer in-charge or Project Officer. |
| 139 | MULTIPURPOSE AUDIO WITH 7.1 DOLBY DIGITAL & LED VIDEO |
| 140 | SITC of FOH Line Array Loudspeaker System. Two-way passive/bi-amp line array loudspeaker array module. LF Transducer - Single 12-inch with 2.5-inch voice coil or better, HF Transducer - 2 x Compression driver, 1.75-inch voice coil or better, Frequency Range -53Hz-20 kHz or better, Sensitivity - 102dB or better, Max continuous SPL - 129dB or better. Power Continuous - 300W or better, Horizontal Coverage - 90° or better, Vertical Coverage - 15° or better. Minimum 4 array modules with 60° of total vertical coverage in each set for better control.IP-54 rated or better. Approved Makes : QSC / Nexo/ d&b Audio technik |
| 141 | SITC of Supply, Installation, Testing and Comminssioning of OEM supplied Array Frame for Line Array Speakers.Approved Makes : QSC / Nexo/ d&b Audio technik |
| 142 | SITC of Passive Flayable or Ground Stacked subwoofer in bass reflex enclosure. Transducers - 18-inch with 4-inch voice coil. Continuous Power - 900W or better, Frequency Range - 34-100Hz or better, Senitivity - 96dB or better, Max continuous SPL - 140dB or better, Omni-directional or cardioid radiation modes. IP-54 rated or better. The Subwoofer should be flyable with the same line array frame or ground stacked as per the site condition. Approved Makes : QSC / Nexo/ d&b Audio technik |
| 143 | SITC Two-way Surface-mount loudspeaker. LF Transducer - 8-inch with 2-inch Voice coil or better, HF Transducer - 1-inch exit with 1.4-inch Voice coil or better, Frequency Range - 55Hz - 20kHz or better, Sensitivity-90 dB SPL or better, Max SPL Continuous/Peak - 113 dB/119 dB or better, Coverage - 105°x105° or better, Rated RMS Power - 200 Watts, Impeadance - 8 Ohms, Transformer taps (70V/100V) - 60,30,15W or better, Enclosure - Painted ABS polymer or similar, Grille -Powder coated aluminum or similar, Ingress protection - IP-54 or better.Shouldbe supplied with OEM mounting bracket / accessories.Approved Makes : QSC / Nexo/ d&b Audio technik |
| 144 | SITC of High-Performance 8-inch Cinema Surround (Left ,Right & Rear) Loudspeaker with all accessories Type:- Two-way, LF Driver:- 8”, HF Driver:- 1”, Rated Power ( Continuous):- 125 W or higher, Frequency Range:- 60 Hz to 20 kHz, Dispersion/Coverage angle:- 135° conical, Maximum SPL:- 117 dB or higher, Nominal Impedance:- 8Ω, Sensitivity :- 90 dB. Approved Makes : QSC / Nexo/ d&b Audio technik |
| 145 | SITC ofGreen Room,Control RoomCompact Surface MountLoudspeaker Driver :5\" or better50 W RMS Output System Sensitivity 87 dB Frequency Range80 Hz - 20 kHz Maximum SPL 111 dB Peak or better 90°or better Horizontal, 60°or better vertical dispersionComplete with mounting accessoriesApproved Makes : QSC /Yamaha/ d&b Audio technik |
| 146 | SITC of Two-way active Stage Monitor Loudspeaker. Amplifier module - 1000 Watt peak power Class-D or better. LF Transducer- 12-inch cone or better, HF Transducer - 1.4-inch compression driver or better, Frequency Range (-10 dB)-47 - 20 kHz or better, Nominal Coverage Angle- 75° Axisymetric or better, Maximum rated SPL - 126 dB or better, Indicators - Power LED, 2 × Input Signal LED, Input B MIC selected LED, Limiter active LED etc. or similar, Enclosure Material-Polypropylene or similar. Approved Makes : QSC /Yamaha/ d&b Audio technik |
| 147 | SITC of Four-Channel Class-D Network Amplifier. Total Power - 8000W or better, which can be asymmetrically distributed across amplifier channels. Should support 16Ω,8Ω,4Ω,70V,100V on each channel individually. Amplifier shall support Power sharing and Bridge and Parallel modes for combining multiple channels. Frequency Response (8 Ω)-20 Hz - 20 kHzor better, Noise Weighted output muted->104 dB or better, Input impedance->8k balanced and >4k unbalanced or better, Front Panel Display for Indication and Control with Knobs and buttons or better. Four or More Routable Mic/Line Inputs or better.Ethernet Ports - 2 Gigabit ethernet ports for network redundancy or better. Approved Makes : QSC /Nexo/ d&b Audio technik |
| 148 | SITC of Four-Channel Class-D Network Amplifier. Total Power - 4000W or better, which can be asymmetrically distributed across amplifier channels. Should support 16Ω,8Ω,4Ω,70V,100V on each channel individually. Amplifier shall support Power sharing and Bridge and Parallel modes for combining multiple channels. Frequency Response (8 Ω)-20 Hz - 20 kHzor better, Noise Weighted output muted->104 dB or better, Input impedance->8k balanced and >4k unbalanced or better, Front Panel Display for Indication and Control with Knobs and buttons or better. Four or More Routable Mic/Line Inputs or better.Ethernet Ports - 2 Gigabit ethernet ports for network redundancy or better. Approved Makes : QSC /Nexo/ d&b Audio technik |
| 149 | SITC of Dual channel 120W amplifierClass D type Nos. of channels 2 Per channel Power output : 2 × 60 W @ 4 ohms, 8 ohms, 70 /100 VTHD 20Hz-20kHz at 1 W <0.5% or better Signal-to-noise ratio>90 dBA or betterFrequency Response 20 Hz - 20 kHz It should be energy star ratedApproved Makes : Labgruppen / Powersoft / Yamaha |
| 150 | SITC of Digital Mixing ConsoleDigital Mixer : 25 motor faders (24 channels + 1 master) ; 48 input mixing channels (40 mono + 2 stereo + 2 return) ; 20 Aux (8 mono + 6 stereo) + Stereo + Sub buses ; 8 DCA groups with Roll-out ; 24 analog XLR/TRS combo mic/line inputs + 2 analog RCA pin stereo line inputs ; 16 analog XLR outputs ; 34 x 34 digital record/playback channels via USB 2.0 + 2 x 2 via a USB storage device ; Dante Card and Network based I/O Stage Box.Approved Makes : Behringer / Yamaha / Allen & Heath |
| 151 | SITC of Open Architecture Digital Signal Processor with minimum 16 Mic/Line inputs and 8 Line outputs. Shall support phantom power on each microphone input. AEC channels - 16 or more with 200ms tail length.Minimum 8x8 Dante channels and support for up to 128x128 Network audio channels via Dante /AES67 or similar protocol. POTS and SIP Softphone integration for Audio conferencing. USB-B port supporting AV USB Bridging for software or web-based conferencing applications emulating USB Audio (Speakerphone) and USB Video (Camera) driver. 24 bit-A/D-D/A converters or better, 48 kHz Sample rate or better, Input frequency response of 20 Hz to 20 kHzor better, Input dynamic range > 109 dB or better. The processor should support Network amplifiers and Expanders without any additional cards or accessories.Approved Makes : QSC / Biamp / Symmetrix |
| 152 | SITC of 7.1 Dolby Surround Sound Processor. Approved Make: DoblyCP950 |
| 153 | SITC of Hypercardioid dynamic handheld Vocal microphoneFrequency Response of 90 - 16,000 Hz Open Circuit Sensitivity –55 dB (1.7 mV) re 1V at 1 PaImpedance-300 ohms or better On/off switch Integral 3-pin gold-plated XLRM-type connectorRugged all-metal construction complete with stand clamp and threaded adaptor and Carry Case. Approved Make: Rode / Shure / Sennheiser |
| 154 | SITC ofCardioid condenserInstrumentmicrophone forGuitars,Piano,Violin, Flute Frequency Response of 40Hz - 20,000 Hz Open Circuit Sensitivity –49 dB (3.5 mV) re 1V at 1 PaMaximum Input Sound Level: 159 dB SPL, 1 kHz at 1% T.H.D.Dynamic Range: 130 dB, 1 kHz at Max SPL Signal-to-Noise Ratio: 65 dB, 1 kHz at 1 Pa Impedance- 200 ohms Integral 3-pin gold-plated XLRM-type connectorRugged all-metal construction. complete with stand clamp and threaded adaptor and universal Clip -OnMount, Violin Mount, 5\" Goosenck for multipurpose use. 4 meter cableinlcuded attacehd to microphoneApproved Make: Rode / Shure / Sennheiser |
| 155 | SITCofHypercardioidCardioidDynamic InstrumentmicrophoneforPercussions, Guitar, Harmonium Frequency Response of 80Hz - 17,000 HzOpen Circuit Sensitivity –56 dB (1.5 mV) re 1V at 1 PaImpedance- 300 ohms Integral 3-pin gold-plated XLRM-type connectorRugged all-metal construction completewithstandclampandthreadedadaptorandsoftpouchincludedApproved Make: Rode / Shure / Sennheiser |
| 156 | SITC of Drum microphone kit. Cardioid condenser microphones ideal for drum overhead miking.4 nos. of cardioid dynamic snare/tom microphones. 1 Nos ofcardioid dynamic kick microphone. 2 xcardioid condenser microphones ideal for drum overhead mikingcomplete with mounts andcarrying caseApproved Make: Rode / Shure / Sennheiser |
| 157 | SITCofCardioid CondenserQuick-MountGooseneckMicrophone withRFI shielding. Element : Fixed-charge back plate, permanently polarized condenserGooseneck Length: 18\"-20\" Frequency Response : 30-20,000 HzImpedance : 250 ohms. Maximum Input Sound Level 138 dB SPL, 1 kHz at 1% T.H.D.Signal to Noise Ratio70 dB, 1 kHz at 1 Pa Dynamic Range 115 dB, 1 kHz at Max SPLRFI-shielding. Complete with Anti-Shock Microphone Stand with on/Off SwitchApproved Make: Rode / Shure / Sennheiser |
| 158 | SITC of DigitalWireless headworn and lapel microphone system Cardioid dynamic Lapel/collar (1 no.) and headworn capsule (1 nos.)Frequency Response of 20 Hz to 20 kHz. RF output power10 mW or better. Total Harmonic Distortion <0.05% typical or better Dynamic Range > >109 dB or better. OperatingFrequencies2.4GHz.ISMband(2400to2483.5MHz)orbetter. Operating range 60 mtrs or better.Audio Sampling 24 bit / 48 kHz Latency 3.8 mS or better.IncludingAntenaExtensionsystemforclearcommunicationbetweenStage and AV Control room. Approved Make: Approved Make: Rode / Shure / Sennheiser |
| 159 | SITC of Digital Wireless Handheld microphone. Hypercardioid dynamic transmitter with 2 nos. Handheld CapsuleFrequency Response of 20 Hz to 20 kHz RF output power10 mW or better. Total Harmonic Distortion <0.05% typical or better. Dynamic Range > >109 dB or better OperatingFrequencies2.4GHzISMband(2400to2483.5MHz)orbetter Operating range 60 mtrs or betterAudio Sampling 24 bit / 48 kHz Latency 3.8 mS or better. IncludingAntenaExtensionsystemforclearcommunicationbetweenStage and AV Control roomApproved Make: Rode / Shure / Sennheiser |
| 160 | SITC of Active Stereo DI Box for electronic instruments 48 V phantom Power Extended Dynamic Range. High quality Neutrik* XLR and high impedance 1/4” TRS connectors. Frequency response 10 Hz to 90 kHz Earth lift switches. Impedance 75 ΩApproved Make: Rode / Shure / Sennheiser |
| 161 | SITC of Floor mount boxes with 8 x XLR Microphone input with Neutrik Connector etc as required Make: Custom with Neutrik Connector |
| 162 | SITC of Floor mount boxes with 2 x XLR Microphone output with Neutrik Connector etc as required Make: Custom with Neutrik Connector |
| 163 | SITC of Passive HDMI face Plate Approved Makes : Atlona / Extron / Lightware |
| 164 | SITC of Video Switcher,4X4 HDMI Switcher with Audio De-Embedder, Should support 4K@60Hz with Chroma Sampling of 4.4.4. Approved Make: Milestone Pro/Extron/Crestron |
| 165 | SITC of Extender, HDMI HDBT Extender with 4K@ 60Hz support withc chroma sampling of 4.4.4. Should cover distance of 60 Mtrs. |
| 166 | HDMI Over Optical Fiber Extender,4K@ 60Hz support withc chroma sampling of 4.4.4. Should cover distance of 200 Mtrs. Approved Make: Milestone Pro/Extron/Crestron |
| 167 | SITC of P2.5 Active LED Display with all required framing, structure, controller, cable, connectors and Installation. Brightness 600 Nits, Refresh Rate 3850 Hz. Size: 25\" x 14\". Approved Make: Unillumin/Viewsonic/AET |
| 168 | SITC of 55\" Commercial 4K Display with floor Stand for the dignataries on stage. Approved Make: LG/Viewsonic/Panasonic |
| 169 | SITC of wireless 10\" I-Pad. 10\" Wireless iPAD for GUI Control. Complete with charging baseApproved Makes : Apple |
| 170 | SITC of 8 port Network Switch. 8 port PoE enabled network switch Approved Makes : Linksys / HP / Netgear |
| 171 | SITC of Wireless Access PointPoE enabled. Standards802.11n wireless LAN802.11g wireless LAN. Approved Makes : Linksys / HP / Netgear |
| 172 | SITC of Rack Structure 42UWith front glass door power distribution boxInternal fans and lights, wheelsApproved Make: Valrack/Netrack/Blurack |
| 173 | SITC of 4 Sqmm x 2 core(12AWG) ATC copper Conductor, Insulated Cores,PVC Sheathed Speaker Cables complete etc as required.(as peractual)Approved Make: Krystal / Canare / Belden |
| 174 | SITC of 2.5 Sqmmx 2 core(12AWG) ATC copper Conductor,Insulated Cores,PVC Sheathed Speaker Cables complete etc as required.(as peractual)Approved Make: Krystal / Canare / Belden |
| 175 | SITCof22AWG2coreATCCopperConductor,PVCInsulated,90%ATCCopperBraidShielded,PVCSheathed Microphone Cable complete etc as required. (as per actual)Supplying and fixinf of Connectors, terminal strips in juncti on boxes & Provision to fly loudspeakers etc as requiredApproved Make: Krystal / Canare / Belden |
| 176 | SITC of CAT-6UTP Cable,4pair,0.58mm Bare copper,ATC Copper Braid Shielded,PVC Sheathed(as per actual) Approved Make: Panduit / AMP / Sommer |
| 177 | SITC of Molded HDMI Cables of various length 3\" / 6\"/10\"Various length of HMI cable 3\",6\",10\" as per design requirement. 18Gbps Bandwidth Approved Make: Atlona / Extron / Kramer |
| 178 | SITC of Various Audio ConnectorsApproved Make: Neutrik / Amphenol / Switchkraft |
| 179 | HVAC |
| 180 | Supply of Voltas (Tata) Make Central Air Conditioners, complete with Indoor & Outdoor Unit, Scroll Compressor, remote Controller, Air Filter, Evaporator Coil,Condenser Coil, Fan Motor and refrigerant etc.Floor Mounted Package AC 21TR |
| 181 | Supply of Voltas (Tata) Make Ceiling Mounted 4-Way Cassette Air Conditioners with wireless Remote |
| 182 | Supply of Voltas (Tata) Make Wall Mounted Split Air Conditioners with wireless Remote. 1.5 TR |
| 183 | Low side Installation Charges - 63 Ton(Copper Refrigerant Piping with Nitrile Insulation Tube, Cable 2.5x4 Core Copper for connection between indoor unit to Outdoor, CPVC Drain 25mm Thick with Necessary fittings, solvent. Installation Charges, GI Ducting works, Insulation works for Duct 13mm (Accoustic & Thermal) Aluminium Grills & Diffuser as per site) |
| 184 | SITC of Copper pipe With Nitrile Tube of Cassette & Split Ac |
| 185 | Supply & laying of Communication cable Cassette & Split Ac |
| 186 | Supply & laying of Drain pipe Cassette & Split Ac |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy