| 1 | Earth work in excavation of foundation trenches or drains in all sorts of soil (including mixed soil but excluding laterite or sandstone) including removing,spreading or stacking the spoils within a lead of 75m.as directed. The item includes necessary trimming the sides of trenches, levelling, dressing and ramming the bottom, bailing out water as required complete. |
| 2 | Earth work in filling in foundation trenches or plinth with good earth, in layers not exceeding 150mm including watering and ramming etc. layer by layer complete. (b) With earth obtained by fresh excavation (including cost of excavation upto 1,800 mm. depth) from land arranged by the Deptt. within a lead of 100 m. |
| 3 | Filling in foundation or plinth by silver sand in layers not exceeding 150 mm as directed and consolidating the same by thorough saturation with water, ramming complete including the cost of supply of sand. (payment to be made on measurement of finished quantity). |
| 4 | Single brick flat soling picked jhama bricks including ramming and dressing bed to proper level and filling joints with powdered earth or local sand. |
| 5 | Cement concrete with 30mm down graded shingles excluding shuttering. |
| 6 | Ordinary cement concrete (mix 1:1.5:3) with graded stone chips (20mm nominal size) excluding shuttering and reinforcement if any, in Ground Floor as per revelent IS codes (ii) River Bazree |
| 7 | Ordinary cement concrete (mix 1:2:4) with graded stone chips (20mm nominal size) excluding shuttering and reinforcement if any, in Ground Floor as per revelent IS codes (ii) River Bazree |
| 8 | Reinforcement for reinforced concrete work in all sorts of structures including distribution bars, stirrups, binders etc. including supply of rods initial straightening and removal of loose rust (if necessary), cutting to requisite length hooking and bending to correct shape placing in proper position and binding with16G black annealed wire at every intersection as per drawing and direction. (a) For works in foundation and upto roof of ground floor/upto 4 m |
| 9 | Hire and labour charges for shuttering with centering and necessary staging upto 4m using approved stout props and thick hard wood planks of approved thickness with required bracing for concrete slabs,beams,columns,lintels curved or straight including fitting , fixing and striking out after completion of works(upto roof of ground ground floor) (f) 25 mm to 30 mm shuttering without staging in foundation |
| 10 | Hire and labour charges for shuttering with centering and necessary staging upto 4m using approved stout props and thick hard wood planks of approved thickness with required bracing for concrete slabs,beams,columns,lintels curved or straight including fitting , fixing and striking out after completion of works(upto roof of ground ground floor) (f) 25 mm to 30 mm shuttering without staging in foundation |
| 11 | Brick work with 1st class brick in cement morter (1:6). In foundation and plinth |
| 12 | 125 mm thick brick work with 1st class bricks in cement morter (4:1) in ground floor |
| 13 | Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding/staging where necessary (Ground floor).[Excluding cost of chipping over concrete surface] |
| 14 | M.S. structural works with hollow sections (square or rectangular shape) conforming to IS: 806-1968 & IS:1161-1998) connected to one another with bracket, gusset, cleat as per design, drawing & direction of Engineer-in-Charge complete including cutting to requisite shape & size, fabrication including metal arc welding conforming to IS: 816-1969 & IS: 9595 using electrodes of approved make and brand conforming to IS:814- 2004, haulage, hoisting and erection all complete.The rate includes the cost of all M.S. Hollow section, all consumables such as electrodes, gas and hire charges of all tools and plants and labour reqired for execution and all incidental chages (such as electricity, labour insurance) etc. complete. |
| 15 | Galvanised corrugated iron sheet work (excluding the supporting frame work) fitted and fixed with 10mm dia J or L hook - bolts, limpet and bitumen washers and putty complete with 150mm end lap at one and one corrugation minimum side lap. In roof . a) with 0.80mm thick sheet |
| 16 | Galvanised iron sheet ridging fitted with necessary bolts,screws, washers etc. complete. (225mm end lap) 450mm lapping each way . ( c ) With 0.80mm sheet |
| 17 | Rendering the surface of walls and ceiling with white cement based wall putty of approved make and brand (1.5mm thk) |
| 18 | Acrylic Distemper to interior wall, ceiling with a coat of solvent based interior grade acrylic primer (as per manufacturer\"s specification)including cleaning and smoothning of surface.Two Coats |
| 19 | Applying Exterior grade Acrylic primer of approved quality and brand on plastered or concrete surface old or new surface to receive decorative textured (matt finish) or smooth finish acrylic exterior emulsion paint including scraping and preparing the surface thoroughly, complete as per manufacturer\"s specification and as per direction of EIC. Two coats i) Water based interior grade Acrylic Primerv |
| 20 | Protective and Decorative Acrylic exterior emulsion paint of approved quality, as per manufacturer\"s specification and as per direction of Engineer-in-Charge to be applied over acrylic primer as required. The rate includes cost of material, labour, scaffolding and all incidental charges but excluding the cost of primer. |
| 21 | Wood works in doors and windows frames fitted and fixed in position including a protective coat of painting at the contact surface of the frame excluding cost of concrete, Iron Butt Hinges and MS clamps.Sishu, Gamar, Champ, Badam, Bhola, Mogra, Hallak |
| 22 | Supplying solid flush type doors of commercial quality, the timber frame consisting of top and bottom rails and side styles of well seasoned timber 65mm wide each and the entire frame fitted with 37.5mm wide battens places both ways in order to make the door of solid core and internal lipping with Garjan or similar wood veneers using phenol formaldehyde as glue etc. complete, including fitting, fixing shutters in position but excluding the cost of hinges and other fittings in ground floor. |
| 23 | Supplying, fitting and fixing M.S. clamps for fitting doors & windows frames made of flat bent bar, end bifurcated with necessary screws etc. by cement concrete(1:2:4) as per direction.40mm x 6mm, 250mm long |
| 24 | Iron butt hinges of approved quality fitted and fixed with steel screws, with ISI mark.(Add Extra 30% for Oxidised Fittings) |
| 25 | Anodised aliminium D-type handle of approved quality manufactured from extruded section conforming to I.S. specification (I.S. 230/72) fitted and fixed complete:(a) With continuous plate base (Hexagonal/ Round rod)vii) 150mm grip x 12 mm dia rod |
| 26 | Anodised aluminium skeleton bolt of approved quality manufactured from extruded section confirming to IS specification (IS 204/74) fitted and fixed with cadmium plated screws: (vi) 450mm long x 12mm dia. bolt. |
| 27 | Anodised aluminium barrel / tower / socket bolt (full covered) of approved manufactured from extruded section conforming to I.S. 204/74 fitted and fixed with cadmium plated screws:(v) 150mm long x 12mm dia. bolt. |
| 28 | Supplying fitting fixing steel windows and ventilators with or without integrated grills confirming to IS 1038 - 1975 and manufactured from rolled sections confirming to IS 7452-1974 with non-friction projecting type, box type hinges, glazing clips, lugs locking bracket, handle plate etcincluding hoisting in position, straightrning if rerquired, fixing lugs in cement concrete (1:2:4) with stone chips 20mm down cutting holes and mending good damages to match with existing surface complete in all respect excluding glazing. Please Enable Macros to View BoQ information Compatibility Report for BOQ20.xls Run on 13-01-2026 12:33 If the workbook is saved in an earlier file format or opened in an earlier version of Microsoft Excel, the listed features will not be available. Significant loss of functionality # of occurrences Version Any effects on this object will be removed. Any text that overflows the boundaries of this graphic will appear truncated. 3.0 BoQ1\"!A1:II43 Excel 97-2003 Minor loss of fidelity Some cells or styles in this workbook contain formatting that is not supported by the selected file format. These formats will be converted to the closest format available. 5.0 Excel 97-2003 |