| 1 | Earth work in excavation of foundation trenches or drains in all sorts of soil (including mixed soil but excluding laterite or sand stone) including removing, spreading or stacking the spoils within a lead of 75m. as directed. The item includes necessary trimming the sides of trenches, levelling, dressing and ramming the bottom, bailing out water as required complete. . |
| 2 | (a) Depth of excavation not exceeding 1.500 mm. |
| 3 | Laying 150 mm. to 200 mm. boulder soling including rough dressing hand packing and ramming down small pieces in the interstics without rolling but including ramming. |
| 4 | Cost of stone boulder 150 mm size delivered ans stacked at site. |
| 5 | (I) Cement concrete with graded stone ballast (40 mm size) excluding shuttering.In ground floor. |
| 6 | (B) With N.B variety stone metal. |
| 7 | (a) 1:3:6 proportion. |
| 8 | Ordinary cement concrete (mix 1:2:4) with graded stone chips (20 mm nominal size) excluding shuttring and reinforcement, if any, in ground floor as per relevant IS codes. |
| 9 | (b) River bazree. |
| 10 | Hire and labour charge for shuttering with centreing and necessary staging up to 4 m. using approved stout props and thick hard wood planks of approved thick ness with required bracing for concrete slabs, beams, columns, lintels curved or staight including fitting fixing and striking out after complection of works. (up to roof of ground floor). |
| 11 | ( c ) 9 to 12 mm. thick approved quality ply board shuttering in any concrete work. |
| 12 | Reinforcement for reinforced concrete work in all sorts of structures including distribution bars, stirrups, binders etc. initial straightening and removal of loose rust (if necessary), cutting to requisite length, hooking and bending to correct shape, placing in proper position and binding with 16 gauge black annealed wire at inter-section, complete as per drawing and direction. |
| 13 | (a) For works in foundation, basement and up to roof of ground floor/up to 4m. Tor steel/Mild steel. |
| 14 | other than SAIL/TATA/RINL/JSW/JSPL/Shyam/SRMB/ISSL/BMASL/Electrosteel |
| 15 | 125 mm. thick brick work with 1st class bricks in cement mortar (1:3) in ground floor. |
| 16 | Plaster ( to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering conrners as directed and raking out joints including throating, nosing and drip course, scaffolding/staging where necessary (ground floor). [Excluding cost of chipping over concrete surface]. |
| 17 | (ii) With 1:4 cement mortar . |
| 18 | (a) 20 mm.thick plaster. |
| 19 | Supplying, fitting and fixing windows and ventilators with or withoutintegrated grills conforming to IS 1038-1975 and manufactured fromrolled steel sections conforming to IS 7452-1974 with non-frictionprojecting type, box type hinges, glazing clips, lugs locking bracket,handle plate etc, including hoisting in position, straightening ifrequired, fixing lugs in cement concrete ( 1:2:4) with stone chips 20mm down cutting holes and mending good damages to match withexisting surface complete in all respect excluding glazing.(Add extra @ 1.2 % for each additional floors upto 4th floor and @1.5% for each addl. Floor above 4th floor.)In Ground floorFlash butt welded windows and ventilators(No shop priming will be allowed to facilitate inspection ofworkmanship)Without integrated grill |
| 20 | (b) Openable steel windows as per IS sizes with side hung shuttersand horizotal glazing bars. [The extra rate admissible for theopenable portion only] |
| 21 | Wood work in door and window frame fitted and fixed in position complete including a protective coat of painting at the contact surface of the frame excluding cost of concrete, Iron Butt Hinges and M.S clamps. (The quantum should be corrected up to three decimals). |
| 22 | (d) Sal : Local. |
| 23 | Panel shutters of door and window, as per design (each panel consisting of single plank with out joint), including fitting and fixing the same in position but excluding the cost of hinge and other fittings.In ground floor.(In case of non-supply of single plank, panel rate of reduction of 20% will be made). |
| 24 | (ii) 40 mm.thick shutters with 19 mm. thick panel of size 30 to 45cm. |
| 25 | (b) sishu,gamar,Champ,badam,bhola, mogra,Hallak, . |
| 26 | (A) M.S. structural works with hollow in roof trusses with tubular sections (TATA make suare or rectangular shape conforming to IS: 806- 1957 & IS: 1161- 1958) connected to one another with bracket,gusset,cleats as per design, drawing & direction of Engineer-In-Charge complete including cutting to requisite size, fabrication with necessary metal arc welding conforming to IS: 816- 1956 & IS: 9595 using electrodes of approved make and brand conforming to IS: 814- 1957, haulage, hoisting and erection all complete. The rate includes the cost of all M.S. Hollow section, all consumables such as electrodes, gas and hire charges of all tools and plants and labour required for execution and all incidental charges (such as electricity, labour insurance) etc. complete.(Payment to be made on the basis of calculated weight of structural members of M.S. Hollow section as specified in relevent IS code in finished work. Payment for gusset, bracket, cleat may be made by adding the actual weight of suc |
| 27 | (i) For roof truss works. |
| 28 | (a) Span up to 12 Mtr. |
| 29 | Supplying, fitting & fixing Zn-Al alloy (55% Al & 45% Zn) coating of 150grams per sq. metre (followed by colour coated on both side) steel sheetwork having minimum yield strength of 550 Mpa of trapizoidal profile ofapproved make as per IS: 15965: 2012 and IS: 14246: 2013 (excludingthe supporting frame work) fitted and fixed with 55 mm & 25 mm selftapping screw, EPDM Washer 16 mm dia & 3 mm th. washer etc.complete with 150 mm end lap and one corrugation minimum side lap.(Payment to be made on area of finished work). In roof With .5mm thick sheet. |
| 30 | Galvanised iron sheet ridging fitted with necessary bolt, screws, washers etc complete. (225 mm end lapping). |
| 31 | (A) 300mm laping each way. |
| 32 | (a) with 0.60 mm.thick sheet. |
| 33 | Galvanized plain sheet works (excluding supporting frame work) fitted and fixed with 6 mm.dia J or L hook-bolts and nuts .sheet-bolts.limpet and bitumen washers and putty with 150 mm. end lap & 50 mm. minimum side lap complete. |
| 34 | (b) In wall : with 0.63 mm.sheets. |
| 35 | Galvanized iron sheet eaves gutter fitted and fixed with necessary 50 mm X 6 mm.M.S.flat bar clamps bent to design, bolts. Nuts, washers etc. complete. Eaves gutter made of 0.63 mm. sheets.(300mm End lapping). |
| 36 | (a) 225 mm. wide gutter. |
| 37 | Supplying bubble free float glass of approved make and brand. Conforming to IS: 2835-1987. |
| 38 | (i) 4 mm thick clear glass. |
| 39 | (a) M.S. or W.I. ornamental grill of approved design joints continuously welded with M.S., W.I. flats and bars for windows ,railing etc. fitted and fixed with necessary screws and lugs in ground floor. (Add extra @1% for each addl. floor up to 4th floor and @1.25% for each addl. floor above 4th floor). |
| 40 | (i) Grill weighing above 10 kg./sq.m.and up to 16kg/sq.m. |
| 41 | supplying, fitting and fixing M.S. clamps for door and window frame made of flat bent bar , end bifurcated with necessary screws etc. by cement concrete (1:2:4) as per direction . ( cost of concrete will be paid separately). |
| 42 | (a) 40mm x 6mm, 250mm Length . |
| 43 | Iron butt hinges of approved quality fitted and fixed with steel screws, with ISI mark. |
| 44 | (iii) 75mm x 40 mm x 1.12 mm. |
| 45 | Anodise aluminium barred/tower/socket bolt (full covered) of approved manufactured from extruded section conforming to I.S.204/74 fitted and Fixed with cadmium plated screws:. |
| 46 | (iii) 100 mm long x 10 mm dia. bolt. |
| 47 | (b) Priming one coat on timber or plastered surface with synthetic enamel oil bound primer of approved quality including smoothening surfaces by sand papering etc. |
| 48 | (a) Priming one coat on steel or other metal surface with synthetic oil bound primer of approved quality including smoothening surfaces by sand papering etc. |
| 49 | (A) Painting with best quality synthetic enamel paint of approved make and brand including smoothening surface by sand parpering etc. in cluding using of approved putty etc. on the surface , if necessary. |
| 50 | (a) On timber or plastered surface: . |
| 51 | (1) With super gloss (hi-gloss). |
| 52 | (iv) Two coats (with any shade except white). |
| 53 | (A) Painting with best quality synthetic enamel paint of approved make and brand including smoothening surface by sand parpering etc. in cluding using of approved putty etc. on the surface , if necessary. |
| 54 | (b) On steel or other metal surface: . |
| 55 | (1) With super gloss (hi-gloss). |
| 56 | (iv) Two coats (with any shade except white). |
| 57 | Add 18% GST |
| 58 | Add 1% Cess Please Enable Macros to View BoQ information |