| 1 | Sch \"A\" Part-I(Building Work):-This Schedule is not Pre-Priced by MES and the Pre-Priced rate indicated as \"Rs. 0.00\" under col.5 signifies this fact only. |
| 2 | Construction of building of Cook House and Dining Hall complete all as shown on drawings and as specified. |
| 3 | TotalAmount of Sch \"A\" Part - II (Site Clearance and Development Work) |
| 4 | TotalAmount of Sch \"A\" Part - III (Internal Water Supply Work) |
| 5 | TotalAmount of Sch \"A\" Part - IV (Internal Electric Supply Work) |
| 6 | TotalAmount of Sch \"A\" Part - V (Plumbing Work) |
| 7 | TotalAmount of Sch \"A\" Part - VI (Area Drainage Work) |
| 8 | TotalAmount of Sch \"A\" Part -VII (Sewage Disposal Work) |
| 9 | TotalAmount of Sch \"A\" Part - VIII (Protective Work) |
| 10 | TotalAmount of Sch \"A\" Part -IX (Path Work) |
| 11 | TotalAmount of Sch \"A\" Part - X (External Water Supply Work) |
| 12 | TotalAmount of Sch \"A\" Part - XI (External Electric Supply Work) |
| 13 | TotalAmount of Sch \"A\" Part -XII (Demolition Work) |
| 14 | Sch \"A\" Part - XIII (Misc Items of work) Note : This Schedule is not Pre-Priced by MES and the Pre-Priced rate indicated as \"Rs. 0.00\" under col.5 signifies this fact only. |
| 15 | Point wiring for One light point/fan point controlled by one switch 5 Amp single pole one-way complete with 1.5 Sqmm (nominal area) PVC insulated, unsheathed and multi strand copper conductor FRLSH cable drawn into and including PVC concealed conduit (heavy duty) and conduit fittings including 1.5 Sqmm PVC insulated unsheathed and multi stranded copper conductor FRLSH cable as earth wire to common earth and connecting to earth dolly including cutting of chases/wall/floor and suitable size of powder coated CRCA mild steel sheet sunken box including 3mm thick laminated sheet top cover for fixing switches, sockets, regulatorsetc complete all as specified and directed. |
| 16 | All as per Srl item No 14 here-in-before but one 5 pin, socket outlet, 6 Amp on the same board |
| 17 | All as per Srl item No 14 here-in-before but one 5 pin socket outlet, 6 Amp on the independent board |
| 18 | All as per Srl item No. 14. here-in-before above but with 4 sqmm single core multi stranded copper conductor FRLSH PVC insulated & unsheathed cable 1100 volt grade and 4 sqmm FRLSH PVC unsulated and unsheathed cable 1100 volt grade with multi stranded copper conductor for earth wire for 15/16 amp on independent board. |
| 19 | All as per Srl item No. 14. here-in-before above but with 2.5 sqmm single core multi stranded copper conductor FRLSH PVC insulated & unsheathed cable 1100 volt grade and 2.5 sqmm FRLSH PVC unsulated and unsheathed cable 1100 volt grade with multi stranded copper conductor for earth wire for 15/16 amp on independent board. |
| 20 | Inverter LED lamp, CDL 12 watt, B22 base, complete all as specified and directed. |
| 21 | Earthing complete with galvanized steel earth plate electrode600mm x 600mm x 6mm buried directly in ground (earth pit not less than 2.25 m deep below ground level) with top edge of earth plate not less than 1.5m below normal ground level connected with galvanized iron earth lead wire 4mm dia by means of bolts, nuts, check nuts and washers of galvanized iron or steel complete, 20mm dia GI medium grade watering pipe with funnel including charcoal, dust, salt, PCC M-15 type B1 in pit with angle iron (25x25x3)mm frame work with precast RCC 1:2:4 type B-1 cover reinforced with 8mm dia TMT bars @ 150mm C/C both ways and 12mm dia MS fabricated handle, test point etc. in and including light grade GI protection pipe 15mm bore up to 7.5m length for drawing in earth lead wire, all as shown in electric plate No. 3 of SSR Part-I complete with necessary earth work in any type of soil, removal of soil to a distance not exc. 50m, testing on completion complete all as specified and directed.Note:- On testing after completion of earthing, if desired earth resistance is not obtained, the earthing will be re-done by the contractor at his own risk & cost to the entire satisfaction. |
| 22 | Concealed sub main wiring of two run with 10 sqmm single core PVC insulated, FRLSH,flexible multi stranded copper conductor cable 1100 volts grade, drawn through and including PVC conduit 25mm dia , medium grade, ISI marked and fixed, including cutting /chasing as required and its accessories including one run of 10 Sqmm single core PVC insulated, FRLSH, multi stranded copper conductor cable as earth continuity conductor in green colour, connected to common earth dolly, complete all as specified and as directed.Note:- Two run of 10 sqmm single core copper conductor cable and one run of 10 sqmm single core copper conductor cable as earth continuity and one run of PVC conduit shall be measured as one unit only. |
| 23 | Concealed sub main wiring of two run with 06 sqmm single core PVC insulated, FRLSH,flexible multi stranded copper conductor cable 1100 volts grade, drawn through and including PVC conduit 25mm dia , medium grade, ISI marked and fixed, including cutting /chasing as required and its accessories including one run of 6 Sqmm single core PVC insulated, FRLSH, multi stranded copper conductor cable as earth continuity conductor in green colour, connected to common earth dolly, complete all as specified and as directed.Note:- Two run of 6 sqmm single core copper conductor cable and one run of 6 sqmm single core copper conductor cable as earth continuity and one run of PVC conduit shall be measured as one unit only. |
| 24 | Supply, installation and comminssioning of refrigerator, double door, BEE 5 star rated, frost free, digital inverter with hermetically sealed compressor of min capacity 310 litres suitable, single phase, AC supply complete all as specified and directed. |
| 25 | Supply, installation and comminssioning of deep freezer, BEE 5 star rated, hard top having capacity 320 litres, single phase, horizontal type, complete all as specified and directed. |
| 26 | Supply, installation and comminssioning of water cooler, fully stainless steel, electric driven, single phase having storage capacity 120 litres and nominal cooling capacity of 60 Litres per hour complete all as specified and directed. |
| 27 | Voltage stabilizer for automatic operation, single phase naturally air cooled, indoor type, wall mounted type & designed for input variation between 60 volts to 280 volts with output stabilized voltage at 230 volts with accuracy of ± 2.5% and of capacity 1 KVA, complete all as specified and directed. |
| 28 | Voltage stabilizer for automatic operation, single phase naturally air cooled, indoor type, wall mounted type & designed for input variation between 90 volts to 280 volts with output stabilized voltage at 230 volts with accuracy of ± 2.5% and of capacity 2 KVA, complete all as specified and directed. |
| 29 | Construction of valve pit of size (60x60x90)cm (Internal dimensions) using PCC (1:4:8) type D-2, using 40mm graded crushed stone aggregate for foundation 10cm thick and 100mm off sets on all sides, 230mm thick brick masonary walls built in cement mortar (1:6), 15mm thick rendering all around the masonry work in cement (1:6), for internal and up to 15cm below GL for external surfaces of walls, 50mm thick PCC (1:2:4) type B-1 coping with 20mm graded crushed stone aggregate including necessary form work for grouting including 3.15mm thick, MS top sheet cover double door with locking arrangement welded to MS frame made out of (50x60x6)mm angle iron frame fixed with hold fasts in coping including painting of steel surface with two coats of synthetic enamel paint over a coat of redoxide primer as finishes coat including necessary excavation in any kind of soil, returning filling in and removal of surplus soil to a distance not exceeding 50m complete all as specified and directed. |
| 30 | Supply, installation, testing and commissioning offactory made \"outdoor type\" CPRI approved dust and vermin proof LT panel board front opening (double shutter) with locking arrangement of suitable size made out of 3.00 mm thick CRCA sheet with 50mm x 50mm x 6mm angle iron frame duly painted with two coats of powder coated paint over a coat of red oxide primer on outer surfaces and epoxy paint on inner surfaces, protection class IP-56, grouted on floor. The LT panel board shall be suitable for operating on AC 415 volts, 3 phase, 50Hz, 4 wire system with suitable of PVC copper conductor for internal wiring,thimbles gland, cable lugs, nuts, bolts, washers, etc. including PCC foundation (PCC 1:2:4 type B-1)of suitable size as per panel board 0.6mtr above ground level grouting and bottom portion of enclosure shall be minimum 60cm above ground level of legs of angle ironand supply & comprising of the following including internal pre-wiring complete:- (Contd.../) |
| 31 | INCOMING:(i) MCCB 4 pole, 16 KA63 Amps - 01 No.OUTGOING:(i) MCCB 4 pole, 16 KA40 Amps - 02 No.(iii) MCB, SPN, 32 Amps, 10 KA - 02 No.(iii) MCB, SPN, 20 Amps, 10 KA - 02 No.(iv) Aluminium bus bar, 4pole of capacity 200Amps-02No.(v) Digital ammeter flush pattern type square dial 96mm x 96mm alongwith selector switch and suitable CT ratio 0-200 Amps -01 No.(vi) Digital voltmeter flush pattern type square dial 96mm x 96mm alongwith selector switch and suitable CT ratio 0-500 V - 01No.(vii) Complete control panel wiring with standard copper conductor of suitable size along with one set indicator lamp for R, Y & B for each incoming and outgoint -feeder -01 No.Note: The rate quoted should include the cost of excavation/PCC work as per manufacturer\"s recommendation. |
| 32 | Earthing complete with galvanized steel earth plate electrode 600mm x 600mm x 6.0mm thick buried directly in ground ( earth pit not less than 2.25 mtr below normal ground level) with top edge plate not less than 1.5 metre below normal ground level connected to galvanized earth strip of size (32x6)mmas earthing lead by means of bolts, nuts, chuck nuts and washers of galvanized iron earth lead with 15 cm thick alternate layers of charcoal dust & common slat including PCC pit in PCC 1:2:4 type B-1, RCC covermade out of cement concrete 1:2:4 type B-1 (using 20 mm graded crushed stone aggregate) reinforced with TMT steel bars 8 mm dia @150 mm c/c both ways with suitable handle andangle iron (40x40x5)mm frame, GI medium grade watering pipe 20mm bore and funnel with wire mesh, GI light grade protection pipe 40mm bore up to main board complete as shown on electrical plate No 3 of MES Sch 2009 (Part-I) and testing on completion complete all as specified and directed. Note: - On testing after completion of earthing, if desired earth resistance is not obtained, the earthing will be re-done by the contractor at his own risk & cost to the entire satisfaction. |
| 33 | Double walled corrugated (DWC HDPE) pipe of size 50mm including snap fit coupler conforming to IS14930 (Pt-II)/IS 16205 Pt-II for protection of under ground cable complete all as specified and directed. |
| 34 | LLDPE septic tank designed to carry sewage and sludge water, comprising earth work, excevation, returning filling, disposal of surplus spoils to a distance not exceeding 50 mtr from starting point in any type of soil, PCC 1:4:8 type D-2 (using 40mm graded crushed stone aggregate) in foundation, 200mm thick, vent shaft, connections etc.for 25 users (4000 liter capacity) including all fittings, fixtures, testing on completion complete all as specified. |
| 35 | Construction of soakage well (Brick Construction) 1.8m dia and 3.0m deep below inlet pipe level (depth from inlet pipe to ground level 45cm), complete all as specified and shown on drg No. CEUZ/TD-1585/2021 sheet 1/4 to 4/4. |
| 36 | 40mm graded crushed stone aggregate, hand packing tightly in wire crating apron bounds, (any thickness) at back side of weepholes and raising or lowering to the required level complete all as specified. |
| 37 | Taking down carefully unserviceable copper/aluminium point wiring of any description including all fittings (switch, socket, switch socket combination, lamp holder, ceiling rose, regulator etc;) complete all as specified and directed. |
| 38 | Dismantling and taking down unserviceable main switches, DB etc; any type/any size complete all as specified and as directed. |
| 39 | Deduction to be made from BOQfor Sch \"A\" Part -XIV (Schedule of credit) amount during AOC.Note: Tenderers shall not quote for this schedule. |