Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | B/R Portion :-Demolition of cement concrete (unreinforced) in ground floors and paving not exceeding 15cm thickness (below or above ground level), complete all as specified and as directed. |
| 2 | Demolition of cement concrete of any description and in any position not otherwise specifically provided for all as specified and directed. |
| 3 | 75mm thick PCC 1:3:6 Type C-2 (using 40mm graded crushed stone aggregates) laid in alternate bays (not exceeding 2 sqm each) as in plinth protection, finished the surfaces even & fair, filled with mastic filling comprising one part of bitumen 85/25 grade and three parts of sand by weight, complete all as specified and directed. |
| 4 | Taking down cement plaster on brick or stone walls etc. including raking out joints, hacking for key, scrubbing down with water etc. complete all as specified and directed. |
| 5 | Rendering 15mm thickon fair faces of brick work or concrete surfaces in CM 1:4 including mixing water proofing compound as per manufacturer\"s instructions, finished even and smooth(without using extra cement) on wall etc complete all as specified and directed. Note :- Supply only WPC shall be measured and paid for separately |
| 6 | Rendering 15mm thickon fair faces of brick work or concrete surfaces in CM 1:6, finished even and smooth(without using extra cement) on wall etc complete all as specified and directed |
| 7 | 5mm thick cement plaster rendering in CM 1:3 on fair faces of concrete surfaces & finishing the surface even and smoothin ceiling, chajja at any height without using extra cement,complete all as specified and directed. |
| 8 | Preparation of new plastered surfaces of walls and applying three coats of white wash on walls complete all as specified and directed. |
| 9 | Preparation of old plastered surfaces of walls and applying two coats of white on wash on walls, complete all as specified and directed. |
| 10 | Preparation of new plastered surfaces of ceiling and applying three coats of white wash on ceiling surfaces compelte all as specified and directed. |
| 11 | Preparation of old plastered surfaces of ceiling and applying two coats of white wash on ceiling surfaces compelte all as specified and directed. |
| 12 | Preparation of new plastered surface of Wall and applying two or more coats of 100% premium acrylic emulsion paint having VOC less than 50gm/ltr and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (company depot tinted) with silicon additives @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ .90 ltr/10 sqm over new surfaces in painting on walls in camouflage pattern with combination of minimum five colours as approved by GE complete all as specified and as directed. |
| 13 | Complete removal of existing treatment on wall and applying two or more coats of 100% premium acrylic emulsion paint having VOC less than 50gm/ltr and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (company depot tinted) with silicon additives @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ .90 ltr/10 sqm over old surfaces in painting on walls in camouflage pattern with combination of minimum five colours as approved by GE complete all as specified and as directed. |
| 14 | Machine cut kota stone slab flooring18-20 mm thick of size 55 cmX 55cm size laid over and including 20mm cement screed bed in CM 1:4 and jointed with grey cement slurry mixed with pigment to match the shade of the slab including grinding and polishing complete all as specified and directed. |
| 15 | All as per item No.14 abovebut in vertical surfaces on and including 15mm thick renderingin CM 1:4, complete all as specified and directed. |
| 16 | Rounding to edges of stone slabs on one edge, such as in manger, steps, cooking platform, and other similar itemscomplete all as specified and directed |
| 17 | 25mm thickPCC 1:2:4, type B-0using 12.50mm graded crushed aggregates as in levelling course to floor surface complete all as specified and directed. |
| 18 | 100mm thick Cement concrete type B-1,1:2:4 (20mm graded aggregate) as in flooring, including necessary formwork, finishing cement concrete surface even and smooth without using extra cement and PCC shall be laid in alternate panels complete all as specified and directed. |
| 19 | 75mm thick PCC 1:4:8 type D-2 (using 20 mm graded stone aggregate) as in sub base complete all as specified and directed at site. |
| 20 | Forming 12mm thick Expansion joints filled with pre-formed bituminous filler and top 30mm primed and sealed with sealing compound, Grade ‘A’ for 100mm slab thickness complete all as specified and directed. |
| 21 | Forming Construction joint 30mm deep x 10mm wide filled with sealing compound Grade \"A\" complete all as specified and directed. |
| 22 | Glazed ceramic coloured tiles 350x250mm /450mmx350mm x7mm thick, as in vertical surfaces such as in skirting and dado etc., set and jointed in neat cement slurry and pointed in white or coloured cement to match the colour of tiles over and including 10mm thick rendering in cement mortar 1:4, complete all as specified and directed by Engr-In-Charge. |
| 23 | 25mm dia MS round pipe heavy grade, fixed to wall withand including suitable arrangement, for hanging of salt for mules complete all as specified and directed. |
| 24 | Two coats of synthetic enamel paint over and including a coat of red oxide primer on steelsurfaces n.exc 10 cm in width or girth including preparation of new or previously untreated surfaces of steel surface complete all as specified and directed. |
| 25 | Taking up or down steel tubing of 20mm bore pipe and connection laid in trenches or floors or fixed to walls and including cleaning for refixing or removal to store with all fittings, Complete all as specified and directed. |
| 26 | Steel water tubing 20mm bore ‘medium grade’ galvanized with all fittings like socket, union, elbow, bend, tees etc fixed to walls and ceiling or laid in floors, complete all as specified ands directed. |
| 27 | 20mm bore gun metal globe or gate valve (ISI marked) with iron wheel head,screwed both ends for iron pipe fixed in repair complete all as specified. |
| 28 | Plain cement concrete 1:3:6 type C-1(using 20mm graded crushed stone aggregate) as in surface channels and drains including necessary formwork, complete all as specified and directed. |
| 29 | Extra for forming fair finished drain or channel 30cm inner girth in cement concrete using extra cement including forms, moulds, mitred/stopper ends etc complete all as specified and directed. |
| 30 | Taking down existing tarfelt including tiles and demolition of concrete & screed bed complete from roof surfaces including parapets and lowering without disturbing the existing RCC roof slab and removing the same to a distance exc. 50m and n. exc.100m incl roughening ofold concrete surface of roofby wire brushing and cleaning the surface to remove all loose dust etc complete all as specified and as directed. |
| 31 | 40mm thick (minimum thickness) PCC type B-0, 1:2:4 (12.5mm graded aggregate) as in padding to roof slab and finishing surface smooth and even to maintain levelling to existing slab complete all as specified. |
| 32 | 15mm thick screed bed or bedding layers in cement mortar 1:4over green surface of concrete on roof surfaces for laying APP based polymeric membrane including mixing with water proofing compound @ 3% or as per manufacturers instruction complete all as specified and as directed. NOTE : Polymeric membrane & Water proofing compound shall be measured and paid separately. |
| 33 | Water proofing treatrment to RCC roof slab, includingparapet comprising with the following courses of treatment/specification from bottom to top :-(a) Applying bitumenous primer @ 0.4 ltrs per Sqmover plastered surfaces of roof including parapet surface.(b)Over the priming coat ,applying a tack coat of bitumen @ 1.2 kg/sqm of paving grade butumen Vg 20 (60-80 penetration) and providing APP based polymeric membrane minimum weighing 3.00 kg/sqm and minimum 3mm thick reinforced with polyster non woven fabric (wt. not less than 200 gms/sqm) laid on bitumen surface by forced application and inserting in groove above 15cm from roof in parapet including minimum overlap of 100mm and 75mm atend and sides of the polymeric membrane respectively and sealed all overlaps and joints with suitable adhesive as per manufacturer\"s instruction and including applying bitumen Vg20 paving grade (60 to 80 penetration) @1.20Kg/Sqm & blinded with fine dry sand @0.50Kg/Sqm including testing by ponding of water. (Note:- (i)Laying of APP bassed polymeric membrane shall bedone with torch application methed or as per manufacturer\"s instructions.(ii)APP based polymeric membrane shall be \"Dr Fixit\" manufacturered by M/S Pidilite Industriesor \"MOPLY FP 3MM\" manufactured by M/S Texsa India Limited and \"Hyperplus\" by IWL India Limited |
| 34 | Supply only liquid water proofing compound of Dr fixit or equivalent make complete all as specified and directed. |
| 35 | Chequred cement concrete tiles, 30cmx30cmx25cm thick, with grey cement and pigment, set jointed and pointed in neat cement slurry in floors laid over andincluding 20mm thick screed bed in CM 1:6 complete all as specified and directed. |
| 36 | Preparation of new plastered or unplastered surfaces of walls and applying two coat of distemper oil emulsion complete all as specified and directed. |
| 37 | Complete removal of existing treatment and preparation of new plastered or unplastered surfaces of walls and applying two coat of distemper oil emulsion complete all as specified and directed. |
| 38 | Preparation of new or previously untreated surfaces of wood over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and directed. |
| 39 | Preparation of old painted steel surfaces over 10 cm in width or girth and applying one coat of synthetic enamel paint complete all as specified and directed. |
| 40 | Demolition of brick or stone masonry, built in cement mortar including all quoins, arches, pillars etc but excluding ashlars facings, dressed stone work, complete all as specified and directed. |
| 41 | Brick work with sub class ‘B’ bricks straight or curved on plan exc 6m mean radius, built in CM 1:6 all as specified and directed. |
| 42 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing ), removing serviceable tile to store and rubbish off the premises, complete all as specified and directed. |
| 43 | Demolition of stone slab and tiles of any description and thickness in floors, aprons etc laid and pointed in any mortar, complete all as specified and directed. |
| 44 | Floor grinding and polishing granite finish to existing kota stone floors including necessary repairs if reqd after each cuttinng i.e filling of joints with white cement, araldite and pigments complete all as specified and directed by GE. |
| 45 | Floor grinding and polishing granite finish to existing kota stone in vertical surfaces including necessary repairs if required after each cuttinng i.e filling of joints with white cement, araldite and pigments complete all as specified and directed by GE. |
| 46 | 20mm thick granite (of approved type colour) work (table rubbed & polished) in jambs, pillars, window cills, cooking plateform laid over and including 15mm thick cement screed (1:4) and jointed with grey cement slurry and pointed with white cement (1:2) with admixture of pigment to match the colour of granite stone including cutting and moulding the edges, complete all as specified and directed. |
| 47 | Non skid coloured ceramic tiles 7 to 8mm thick (square/rectangular) area of each tile exc 0.11Sqm but n exc. 0.18Sqm in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles, laid over and including 15mm thick screed bed in CM (1:6), complete all as specified and directed. |
| 48 | Taking down chowkhats or framesexc 1.5 Sqm but n.exc 4 Sqm with shutters (without taking off shutters from frame)complete all as specified and directed |
| 49 | Taking down chowkats or frames n exc 1.50 Sqm with shutters (without taking off shutters from the frame) complete all as specified and directed. |
| 50 | Taking down shutters of any description exc 2.0 sqm each complete all as specified and directed. |
| 51 | Factory made Pressed steel frames of size 125x60mm made out of PBI sheet 1.25 mm thick for doors with one or more rebates including necessary fixing lugs, hinge,lock strike plate etc.complete including bottom of each chowkat to be welded with 02 Nos 25x3mm thick Flat iron projecting 10cm on either side & PCC 1:3:6 type C-0 in back filling of chowkats & tarring back of chowkats and hold fastscomplete all as specified & directed. |
| 52 | 35mm thick 2nd class hard wood plain, framed, panelled shutter (any number of panels) with panels of timber flat on both sides (feather edged) or of veneered particle board medium density, wood particle board with commercial face veneers complete all as specified and directed. |
| 53 | 35mm thick 2nd class hard woodglazed and skeleton shutters, open rebated and prepared to receive glass, gauge etc divided into squares with plain chamfered or rounded, mitred and rebated shash bars, any numbers, edges of framing plain, chamfered or rounded fitted with cut and mitred beads for securing glass etc, sizes of members of shutters , supplied & fitted to chowkats complete all as specified and directed. |
| 54 | Solid PVC Door Frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S. Square tube, suppling & fixing in opening as per specification & drawing complete all as specified and directed. |
| 55 | Factory made solid core PVC door shutter 30mm thick (style) consisting of frame made out of MS tubes for top and bottom rails. MS frame shall be covered with heat moulded plain colour PVC sheet, \"C\" channel having PVC sheet strip of 20mm width stuck inside with solvent cement for styles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap inserted for top rail and bottom rail; panelling of plain colour PVC sheet to be fitted in MS frame welded/ sealed to the stiles and rails with suitable PVC sheet beading and joined together with solvent cement complete all as specified & shown in relevant drawing of item No. 08080 in MES Schedule (Part-II) and directed by Engineer-in-Charge. |
| 56 | Mild steel butt hinges, medium weight, cold rolled,100mm long, complete all as specified and directed. |
| 57 | Aluminium anodised, barrel tower bolts of extruded section of size 150mm and fixed, complete all as specified and directed. |
| 58 | Aluminium anodised, barrel tower bolts of extruded section of size 100mm and fixed, complete all as specified and directed. |
| 59 | Aluminium alloy handles, cast type, anodised of size 150mm and fixed, complete all as specified and directed. |
| 60 | Aluminium alloy handles, cast type, anodised of size 100mm and fixed, complete all as specified and directed. |
| 61 | 200 mm long aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy and fixed. |
| 62 | 300 mm long aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy and fixed. |
| 63 | Steel ventilator with top hung shutter including hinges, steel peg stay, complete all as specified and directed. |
| 64 | Steel windows with side hung shutters including projecting type hinges with steel handle, and steel peg stay, complete with glazing bars, dovetailed or welded, complete all as specified and directed. |
| 65 | 3mm thick Sheet glass of ordinary quality,glazing with oil putty or wooden beads in squares not exceeding 0.50Sqm in each pane, complete all as specified and directed. |
| 66 | Supply and fixing in repairs 3mm thick Sheet glass of ordinary quality,glazing with oil putty or wooden beads in squares not exceeding 0.50Sqm in each pane, complete all as specified and directed. |
| 67 | Stainless steel wire cloth, 0.56mm nominal dia of wire and average width of aperture 1.18mm and fixed with aluminium wire staples or wooden beading complete allas specified and directed. |
| 68 | Supply and fixing in repair Stainless steel wire cloth, 0.56mm nominal dia of wire and average width of aperture 1.18mm and fixed with aluminium wire staples or wooden beading complete allas specified and directed. |
| 69 | Vitreous china squatting pan (Orissa pattern) size 580 x 440 mm, snow white, with \"P\" or \"s\" trap, front or back inlet and integral foot rests, complete connection to drain (outgoing pipe) and to flushing pipe and syphonage pipe etc. fixed in repairs including lime concrete bedding, complete, all as specified. |
| 70 | Vitreous china wash down water closet pan (pedestal pattern), white with seat cover and hinging device including all fittings, fixing nuts, bolts, connection to drain (or outgoing pipe) and to flushing pipe, antisyphonage pipe etc fixed in repair,complete all as specified and directed. |
| 71 | Supply and fixing in repairs health faucet (ABS Body) mild steel chromium plated suitable for 15mm dia pipe with 1.25 metre long flexible tube and ABS wall hook including making connections and fixed in position complete in all respect as specified and directed. |
| 72 | Vitreous china bowl urinal flat back small- normal, size of 465X355X265mm white (minimum), with grating and union for discharge pipe including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60mm long brass screws and pointing around urinal back in cement (excl flushing cistern, flush pipe and waste pipe) etcfixed in repair, complete all as specified and directed. |
| 73 | Supply and fixing in repair, Vitreous china wash basin, counter type oval shape size 550 x 400 mm excl taps, wastechain and plug and porcelain stopper but including brackets, waste pipe & CP waste coupling complete all as specified and directed. |
| 74 | 15mm brass chromium plated basin mixerfor mixing hot & cold water screwed down for iron pipe fixed in repair, complete all as specified and directed. |
| 75 | PVC valve less symphonic action type flushing cistern 10ltr capacity , low level white with inlet ball valve float and handle including brackets including 32mm dia PVC. flush pipe for low level cistern including all joints fixed in repair , complete all as specified and directed. |
| 76 | 15mm bore Stop valve/angle cock, cast copper alloy chromium plated fancy type screwed down high pressure with crutch or butter-fly handle, screwed both ends for iron pipes or for union, fixed in repairs, complete all as specified. |
| 77 | 20mm dia Concussive push button taps of cast copper alloy, screwed for iron pipe and fixed for urinal complete all as specified and directed. |
| 78 | Bib taps 15mm bore of cast copper alloy chromium plated fancy type, screwed down, high presure with crutch or butterfly handle, screwed both ends for iron pipe or for brass ferrule, fixed, complete all as specified and directed. |
| 79 | PVC connection 15mm size with CP nuts on both ends of length 600mm fixed in repairs, complete all as specified and directed. |
| 80 | Grating doom 125 mm dia with waste hole of PTMT, (Minimum weight 40gms) fixed in repairs complete all as specified and directed. |
| 81 | Supply and fixing in repair 600mm x 450mm size bevelled edge mirror with border, selected quality 5mm thick glass mounted on 6mm thick AC building board or commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers complete all as specified and directed by Engineer-in-Charge. |
| 82 | Brass chromium plated shower rose 125mm size with or without swivel joints, any size, including fixing to steel pipe or union all as specified and directed |
| 83 | Soap dish of CP fixed with and including chromium plated brass screws and wooden/plastic plugs, fixed in repairs, all as specified and directed. |
| 84 | Sheet glass shelf assembly consisting of 5.5mm thick sheet glass shelf 12cm wide with chromium plated bracket guard and railing 60cm long complete all as specified and directed. |
| 85 | Tubular towel rail 60cm long 20mm dia aluminium anodised incl necessary brackets, fixed in repair, complete all as specified and directed. |
| 86 | Dismantling of cast iron drain pipe of any dia set in cement mortar/concrete and taking out of trenches if required, complete all as specifie and directed. |
| 87 | PVC (SWR) floor trap of 75mm dia of outlet, plain with grating including jointing with solvent cement fixed in repair, complete all as specified. |
| 88 | PVC (SWR) pipes 75mm dia, Type B, any length single socketed with rubber ring joint, laid in floors , complete all as specified and directed. |
| 89 | PVC (SWR) pipes 75mm dia, Type B, any length single socketed with rubber ring joint, laid in walls , complete all as specified and directed. |
| 90 | PVC (SWR) pipes 110mm dia, Type B, any length single socketed with rubber ring joint, laid in floor, complete all as specified and directed. |
| 91 | PVC (SWR) pipes 110mm dia, Type B, any length single socketed with rubber ring joint, laid in walls, complete all as specified and directed. |
| 92 | PVC (SWR) bends any radius 75mm bore fixed, complete all as specified and directed. |
| 93 | PVC (SWR) bends any radius 110mm bore fixed, complete all as specified and directed. |
| 94 | PVC(SWR) branch piece, single (single Y) equal or unequal 75mm bore fixed in repair, complete all as specified and directed. |
| 95 | PVC(SWR) branch piece, single (single Y) equal or unequal 110mm bore fixed in repair, complete all as specified and directed. |
| 96 | PVC (SWR) junction single (single T) 75mm bore equal or unequal, fixed in repairs, complete all as specified and directed. |
| 97 | PVC (SWR) junction single (single T) 110mm bore equal or unequal, fixed in repairs, complete all as specified and directed. |
| 98 | PVC (SWR) vent cowl for 75mm dia fixed in repair, all as specified. |
| 99 | Dismantling water tanks of any description exc 500 & nexc1000 litre capacityand removing from site complete all as specified and directed. |
| 100 | Rotational moulded polyethylene water storage tankstriple layer (Cylindrical vertical with closed top), ISI marked hoisted and fixed in position all as spd in SSR Pt-I,of capacity1000 Ltrs including making necessary connection and fittings, complete all as specified and as directed. |
| 101 | Ball brass valves, high pressure, with polythene float and fly nut complete screwed for iron pipe or brass ferrule, 20mm bore fixed, complete all as specified and directed. |
| 102 | 20mm bore gun metal globe or gate valve (ISI marked) with iron wheel head,screwed both ends for iron pipe fixed in repair complete all as specified. |
| 103 | Rendering 10mm thick in CM 1:3 on fair faces of brick work or concrete surfaces finished even and smoothusing water proofing compound @ 3% on sunken portion complete all as specified and directed(NOTE : Supply only water proofing compound shall be measured and paid separately). |
| 104 | Preparation of surface by brushuing and cleaned of all dust and applyingbituminous primer conforming to IS-3384 applied @0.7 litres per of wall and slab, after drying of primer apply evenly a coat of hot blown 85/25 gradebitumen at the rate of 1.20 kg per square metre, providing polymeric water proofing membrane ISI marked laid with over laps bonded with cold cut back adhesive, overlap shall not be less than 150mm, and over membrane applya coat ofsemi hot blown 85/25 gradebitumen at the rate of 1.20 kg per square metre on sunken portion including testing by ponding complete all as specified and directed. |
| 105 | Loose filling ofbrick bats 80 to 150 mm in sunken portion complete all as specified and directed |
| 106 | Taking up or down steel tubing of 15mm bore pipe and connection laid in trenches or floors or fixed to walls and including cleaning for refixing or removal to store with all fittings, Complete all as specified and directed. |
| 107 | 16mm dia 3-layer PP-R (Polypropylene random copolymer) concealed pipes SDR 7.4 (PN16) UV stabilized and antimicrobial fusion welded having thermal stability for hot & cold water supply including all PP-R plain & brass threaded polypropylene random fittings fixed complete to walls, ceilings or in floors etc complete all as specified and directed. |
| 108 | 20mm dia 3-layer PP-R (Polypropylene random copolymer) concealed pipes SDR 7.4 (PN16) UV stabilized and antimicrobial fusion welded having thermal stability for hot & cold water supply including all PP-R plain & brass threaded polypropylene random fittings fixed complete to walls, ceilings or in floors etc complete all as specified. |
| 109 | Steel water tubing 25mm bore ‘medium grade’ galvanized with all fittings like socket, union, elbow, bend, tees etc fixed to walls and ceiling or laid in floors/trenches, complete all as specified ands directed. |
| 110 | Framed work such as grills, gratings, etc. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165 |
| 111 | Prelaminated particle board, interior grade, prelaminated both sides with decorative choice lamination , fixed with screws to timber frame work for in built table top including fixing of 4mm thick teak wood beading at edges of table top allaround complete all as specified and directed. |
| 112 | E/M PORTION:-Taking down carefully copper/aluminium point wiring for light, bell socket power socket etc complete with boards, outlet boxes fittings and fixtures such as switchs, sockets, lamp holders bracket,ceiling rose, celing fan etc and making good to disturbed surfaces of wall, floor etc to match with existing finishes complete all as specified and directed. |
| 113 | Point wiring with 2x1.5 sqmm (nominal cross section area) FRLS PVC insulated unsheathed multistranded copper conductor cable and 1x1.5 sqmm (nominal cross section area) FRLS PVC insulated unsheathed multistranded copper conductor cable as earth continuity to common earth dolly running in and including PVC casing & caping (ISI marked) of suitable size with PVC boards of approporiate size and all requisite accessories such as PVC elbow, Tee, collars, bends etc with PVC terminals box& cover for mounting switches, sockets, fan regulator etc complete all as specified and as directed for the following:- |
| 114 | One light/fan point controlled by one switch complete all as specified and directed. |
| 115 | One 5 Pin, 6 amp socket outlet on same board complete all as specified and directed. |
| 116 | One 5 Pin, 6 amp socket outlet on independent board complete all as specified and directed. |
| 117 | One light point controlled by two numbers two way switches |
| 118 | All as per item No. 113 above but with two 2.5 sqmm size cable as phase and neutral and one 2.5 sqmm size cable as earth continuity for 15/20 amp multipurpose socket outlet on independent board complete all as specified and directed. |
| 119 | Ceiling rose, 3 phase,bakelite 65x50mm two or three therminals complete all as specified and directed. |
| 120 | Piano Type switch , 1 way, 6 amp, flush type complete all as specified and directed. |
| 121 | Piano Type switch , two way, 6 amp, flush type complete all as specified and directed. |
| 122 | Socket outlet 2 in 1, 5 pin 6 Amps, flush type complete all as specified and directed. |
| 123 | Switch socket combination 2 in 1 , 5 pin 6 Amp, flush type complete all as specified and directed. |
| 124 | Switch socket combination 2 in 1 , 5 pin 6and 16 Amp, flush type complete all as specified and directed. |
| 125 | Supply and fixing in repair Inverter LED light fittings, 1x20 w LED, 230 V complete with all accessories internally per wired including lithium Ion battery with charging time 8-10 hours and back up time upto 4 hours andconnecting up with PVC insulated and sheathed, 1100 v grade, flexible, multistranded copper conductor three core cable complete all as directed. |
| 126 | Supply and fixing in repair wall mounted fan complete with all accessories including fixing arrangement ,AC single Phase, 230V, 50Hz of size 450mm sweep, plastic body with 5 star, rating complete all as specified and directed. |
| 127 | Supply and fixing in repair LED street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and directed. |
| 128 | Supply and Fixing in repair Sheet Metal enclosure for SPN DBs, 4 Ways, Double Door (IP-43), with netral link complete suitable for 240 Volts, AC, 50 Hz complete all as specified and directed. |
| 129 | Supply and Fixing in repair MCBs, SPN, 240 volts, breaking capacity 10 KA, \"C\" series, rating 40-63 amps,complete all as specified and as directed. |
| 130 | Supply and Fixing in repair MCB, SP,240 volts, breaking capacity 10 KA, \"C\" series, rating 6 to 32 amps, complete all as specified and as directed. |
| 131 | Earthing complete with galvanised steel earth plate electrode 60cm x 60cm x 6mm thick buried directly in ground (earth pit notless than 2.25 m below ground level) with top edge of the earth plate not less than 1.5 m below ground level, connected to GI earth wire 4mm dia by means of bolts, nuts,check nuts and washers of galvanised iron or steel all as shown in electrical plate No 3 of SSR Part-I, connected to earth test point all as specified or indicated including excavation and connected earth work in soft / loose soil, P.C.C 1:3:6 type C-1 as in pit, 20mm dia GI pipe medium grade for watering pipe, 15mm bore GI medium grade earth lead protection pipe, 50mm thick R.C.C. 1:2:4 type B-1 cover slab of earth pit reinforced with 8mm dia TMT bars @ 10cm C/C both ways and with handle made out of 10mm dia bars, funnel, strainer,charcoal and testing on completion including dismantling unserviceable earthing complete all as specified and as directed. |
| 132 | Supply and laying or fixing or passing through pipe, 1100 volts grade heavy duty cable with PVC insulated aluminium conductor served with an inner sheathing of PVC tape armouredwith galvanised steel wire or tape and overall PVC sheathed 10 sq. mm nominal cross section in service connections complete all as specified and directed. |
| 133 | Lamp holder PVC/Polycarbonate type with back plate suitable for batten fittings, complete all as specified and directed. |
| 134 | Invert Led Lamp , CDL 12 Watt , B22 base all as specified and as directed. |
| 135 | Supply and fix in repairs Electronic step regulator (speed regulation in 5 steps) suitable for ceiling fan 1200 / 1400 mm sweep complete all as specifiedand as directed. |
| 136 | Supply and fixing in replacementLED tube light fittings mirror type with hight output diffuser 1 feet, 5/6 watt 220V AC, decorative type with driver holder and LED lamp including connectiong up with 3 core flexible copper conductor cable of suitable size complete all as specified and directed. |
| 137 | Supply and fixing in replacement 1N x 9W LED lamp, decorative wall light fixture made up of polycarbonate, suitable for 9W LED lamp B22 base complete with all accessories internally per wired including and connecting up with PVC insulated and sheathed, 1100 V grade, flexible, multistranded copper conductor three core cable complete all as directed. |
| 138 | Sheet metal enclosure TPN vertical suitable for TP/FP G frame MCCB of cap upto 100 Amps, double door each of 4 ways, built in bus bars complete suitable for 415 volts, AC, 50 Hz complete all as specified and directed. |
| 139 | Supply and Fixing in repair Sheet Metal enclosure for SPN DBs, 8 Ways, Double Door (IP-43), with netral link complete suitable for 240 Volts, AC, 50 Hz complete all as specified and directed. |
| 140 | Supply and fixing in repairs MCBs, TPN, 415 volts, breaking capacity 10 KA, rating 20-63 amps, complete all as specified and directed. |
| 141 | Supply and fix in repair sub main wiring with single core cable 2 x 4 sqmm FRLSinsulated unsheathed stranded copper conductor cable 1100 Volts grade drawn through PVC casing/caping 25 mm dia ISI marked fixed on wall/ceiling,alongwith 1x2.5 Sqmm FRLS insulated unsheathed copper conductor cable as earth wire connected with main earth dolly , complete all as specified and directed.Note:-Two runs of4sqmm cable alongwith one run of 2.5sqmm PVC insulated copper conductor as earh wire inclcasing caping shall be measured as one unit. |
| 142 | Supply,laying, jointing and testing XLPE and PVC insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 25 sqmm 4 core complete all as specified and directed. |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail