| 1 | Material and Labour for providing dark coloured finish UPVC profile casementwindows (penable) profile frame consist of high impact modified grade uPVC of 60mm x 74mm (outer frame) and sash of 65mx105mm, wall thickness of profile must be minimum 1.8± 0.3 mm, which shall be manufactured from tropicalized blend with T Profile and required additives, profile shall be colorfast and conform to standard EN12608, prfile stations shall have multi hollow (min 2 to 3 chabers) chamber to include GI reinforcement with 120 GSM zinc coated, fitted in continuous length, in closed chamber, the thickness of GI shoud be selected to meet the wind load requirement as per IS 875- part-III on sash/mullion and minimum steel steel reinforceent thicknesss of 1.2 mm to 2.5m, UPVC casement Windows shall be fabricated with fusion welded corners and conform to the strengthrequireents based on wind load as per IS 875-part -III. All hardwarefitted must be stainless steel except handles to be of zinc/Stainless steel, alloy casted Gde 304. Glass shall be of laminated(6T+ 1.23pvb+5T) 8mm thicktoughened glass with weather seal (EPDM/TPE). UPVC casement windows shall be installed by profile manufacturer only, Fame fastener 8mmx100mm type shall be used area exceeding 1.0sqm but not execeeding 2.0sqmeach compete all specified and as directed by Engineer in charge.Make: Fenesta or equivalent. |
| 2 | Material and Labour for providing dark coloured finish UPVC profile casement Doors profile frame consist of high impact modified grade uPVC of 60mm x 58mm (outer frame) and sashof 60mx78mm, wall thickness of profile must be minimum 1.8± 0.3 mm, which shall be manufactured from tropicalized blend with T Profile and required additives, profile shall be colorfast and conform to standard EN12608, prfile stations shall have multi hollow (min 2 to 3 chabers) chamber to include GI reinforcement with 120 GSM zinc coated, fitted in continuous length, in closed chamber, the thickness of GI shoud be selected to meet the wind load requirement as per IS 875- part-III on sash/mullion and minimum steel steel reinforceent thicknesss of 1.2 mm to 2.5m, UPVC casement Doors/Windows shall be fabricated with fusion welded corners and conform to the strengthrequireents based on wind load as per IS 875-part -III. All hardwarefitted must be stainless steel 3D hinges, handles to be of zinc/Stainless steel, alloy casted Gde 304. Glass shall be of laminated(6T+ 1.23pvb+5T) 5mm thicktoughened glass with weather seal (EPDM/TPE). UPVC casement Doors shall be installed by profile manufacturer only, Fame fastener 8mmx100mm type shall be usedcomplete all specified and as directed by Engineer in charge.Make: Fenesta or equivalent. |
| 3 | Taking down Chowkats or frames exceeding 1.5 Sq. M but not exceeding 4 Sq. M each (without taking off shutters from the frame) complete all as specified and directed. |
| 4 | Demolition of brick work or stone/ boulder masonry, built in cement mortar including all quoins, pillars or at any position and removal of debris from site complete all as directed. |
| 5 | M&L for precast cement concrete hollow solid blocks exc 10cm widthMasonry type1:3:6 (16 mm using aggregate as per IS 383) set in cement mortar 1:6 all as specified and as directed by engineer in charge |
| 6 | Material and labour for precastPCC 1:3:6 Type C1 using 20 mm graded aggregate solid block masonrynot exceeding 10 Cm width(with plain or interlocking joints as directed), built in cement mortar 1:6 all as specified and as directed. |
| 7 | Taking down cement plastering on concrete or Brick works surface racking out joints, hacking for key , scrubbing down with water, removing rubbish/debris etc complete all as specified and as directed. |
| 8 | Material and labour for rendering 15mm thick in cement mortar 1:6 on other than fare face of brick work or concrete surfaces and finishing the surface even & smooth without using extra cement onany height complete all as specified and directed by Engr-in-charge. |
| 9 | Material and labour for rendering 15mm thick in cement mortar 1:4 on other than faire face of brick work or concrete surfaces and finishing the surface even & smooth without using extra cement on any height complete all as specified and directed by Engr-in-charge. |
| 10 | Material and labourfor applying two coat of Distemper oil emulsion by Auto Roller over a coat of primer over 1 to 2 mm thick birla putty punning including finishing bySanding Machine and Auto Roller new surface complete all as specified or as directed by Engineer-in-charge.Make: Asian Paint (Tractor)/Berger paints (Bison super) |
| 11 | Material and labourfor preparingold distemper and painted surfaces of walls including washing rubbing down andbrooming down smoke soot mould mass and applying one coats of Oil emulsion distemper old surface complete all as specified and directed by Engr-in-charge. |
| 12 | Material and labour for preparingold distemper and painted surfaces of ceiling including washing rubbing down andbrooming down smoke soot mould mass and applying one coats of Oil emulsion distemper old surface complete all as specified and directed by Engr-in-charge. |
| 13 | Material and labour for applying two coat of exterior Acrylic emulsion paint (100% acrylic) of approved colour and shade over a coat of primer and over 1 to 2 mm thick birla putty punning including preparation of new plastered surface complete all as specified and as directed by Engineer-in-charge. Make-Asian (Apex Ultima) paints/Berger (Whether coat long life) including necessary scaffolding . |
| 14 | S&F for colour powder coated aluminiumframe for, doors ,windows, ventilators with one or more rebates including joining cleat for fixing etc. complete all as specified and directed by Engr In Charge |
| 15 | Supply and fix for10mm thick toughtned glass pane reuired colour and sizeincluding all necessary hardwarefittings doors window/partitionscomplete all as directed by Engineer in charge. Make: saintgobin/modiguard |
| 16 | Material and labour for prelamiated both side with decorative choice particle board of9mm fixed to partitions/ almirah/doors and similar work . etc in a any shape and in any direction etc to the required size and desired pattern and colour as specified and directed by EIC |
| 17 | Supply and fix lnsulated PVC Wall Lining consisting of PVC Insulated Panels (25mm thick insulated PVC wall lining) having expanded polystyrene (EPS) stuck to 2mm thick plain colour PVC sheet duly fitted into the wall of any shape and any colourat any position Each panel have to interlock with each other complet all as per manufactures instruction complete all as specified and asdirected by Engineer in Charge. |
| 18 | M&L for20 mm thick granite slab of any size for windowcill ,counter top and similar work over and including 15 mm thick screed bed or bedding layer ofcement mortar 1:4 laid and jointed with grey cement slurry mixed with pigment to match the shade of slab including making good the edges complete all as specified and directed by Engr-in-charge. |
| 19 | Dismantling floor, hearth or wall tiling including cement mortar bedding and removing rubbish off the premises complete all as specified and as directed. |
| 20 | Material and Labour for glossy finish coloured vitrified ceramic tiles 8-10 mm thick of area of each tiles not exceeding 0.42 sqm but not exceeding 1.0 Sqm, of any shade of any pattern (pattern consists combination of two or more tiles ) as in floor/vertical surfaces etcjointed in neat cement slurry and pointed in colored cement to match colour tiles over and including 15mm thick screed bed in CM 1:6 and pointed in coloured cement to match coloured tiles complete all as specified and as directed.NOTE: No extra cost sahll be allowed for Removing and re-fixing and necessary cutting of door etc if any required during execution of work. |
| 21 | Material and Labour for glossy finish coloured vitrified ceramic tiles 8-10 mm thick of area of each tiles not exceeding 0.42 sqm but not exceeding 1.0 Sqm, of any shade of any pattern (pattern consists combination of two or more tiles ) as in vertical surfaces etcjointed in neat cement slurry and pointed in colored cement to match colour tiles over and including 10mm thick screed bed in CM 1:4 and pointed in coloured cement to match coloured tiles complete all as specified and as directed. |
| 22 | Supply and fix for 10mm thick Vitrified light shade Coloured tiles, square/rectangular double polished, area of each tile n.exc. 0.36 sqm,in floor including 15mm thick screed bed in CM 1:4 etc.,set and jointed in neat cement slurryand pointed in white with pigment to matchfor laying floor finishes all as specified and as directed . |
| 23 | Material and Labour forcut kota stone slab flooring 20-25mmthick overcement screed bedbase laid and jointed with grey cement slurry mixed with pigment to match the shade of the stone slab including rubbing and polishing and 20 thick screed bed CM 1:4 complete all as specified and as directed |
| 24 | M&L for 25mm thick PCC 1:2:4Type B0 (12.5mm Graded Stone Aggregate) as in sub floor/window cills and like worksetc., including rough top surface to receive floor finish complete all as specified and as directed. |
| 25 | M&L forFalse ceiling with 12mm thick size 1.2m x 1.80m Pop gypsum board sheets fixed with machine screws as per manufacture instructions and including G I channel 22 guage thick grid work main joints placed at 1.20m centre to centre cross joints placed at 450mm centre to centre, hanging with 22 gauge GI strip suspenders fromroof \"J\" hooks bolts and nuts etc and treating the Gypsum board with thin layer of Gypsumwith gypsum and hydrous binder and prepare the surface till smooth surface is achieved and applying two coat ofoil boud distemper of any patterrn and design over a coat of texture primer on ceilings sheets all complete as required as per manufacture\"s instructions and directed by the EIC1. The pattern and design shall be as directed by Engineer in charge during the execution of work.2. The exposed surface of the false ceiling shall be joint less even and smooth to receive two coats of oil bound distemper3. The Gypsum board (Pop)/sheets shall be fixed with suitable screws below the grid and shall not be placed over the grid |
| 26 | Removal of debris/malwa to a distance exc 1.5Km but n exc 5 Km and depositing out side the MD land and asdirected by Engr-in-charge. |
| 27 | Schedule of Credit (Minus) Rs.38900.00 NOTE: Bidder shall insert credit amount of Rs. 38900.00as ratein Green field under Col-13. |