| 1 | Excavtion in post holes (or similar holes) each not exc. 0.50 cum in any kind of soil getting out,and removing surplus soil to a distance not exc. 25 mtr and making good of surfacescomplete all as specifiedand as directed. |
| 2 | M&L PCC 1:3:6type C2 ( using 40 mm graded aggregates) as in foundation filling and mass concrete complete all as specifiedand as directed. |
| 3 | M&L for providing cement concrete 1:4:8 type D2 (Using 40mm graded stone agg) in foundation, mass concrete, and filiings complete all as specifiedand as directed. |
| 4 | S&F Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws complete all as specified and directed. |
| 5 | S & F Pre-painted galvatume aluminum zinc coating GI based plain steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws complete all as specifiedand as directed. |
| 6 | S&F steel work in tubular trusses including special shaped washer etc complete using ERW or induction butt welded tube conforming to IS 1161-1979 grade St-240 complete all as specified and directed |
| 7 | M&L Mild steel Plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment conforming toFe-410W Gde E-250 quality B all as specified and directed. |
| 8 | S&Ffor 11 to 15 mm mild steel screws bolts (machine made) with hexagonal or square heads at one end and screws both ends each screwed end to be fitted with washers and one hexagonal or square nut exc 5cm not exc 10 cm long complete all as specifiedand as directed. |
| 9 | S&F framed brackets of angles or tees with web and flanges cut to shape, drilled and countersunk for screw, including bending and welding angles, as necessary, gusset plate, riveting, etc n.exc 10 kg each brackets, conforming to Fe-290. Gde E-165 .complete all as specified and directed |
| 10 | Preparation of newly steel surfaces of any description over 10 cm width or girth andapplying two coats synthetic enamel paint over a coat of red oxide primer.complete all as specified and directed |
| 11 | M&L fly ash Brick curved on plan exc 6 metre mean radius built in cement mortar (1:6) complete all as specifiedand as directed. |
| 12 | Material & labour for Rendering 15 mm thick CM 1:4 on brick or concrete surfaces finished even & smooth without using extra cement complete all asspecified and directed. |
| 13 | Material and labour for PCC 1:2:4 type B1 (using 20mm graded stone aggregate as in cills, steps, parapets and copings, kneelers, bed plates, hold fasts block, filling on pressed steel door frame etc complete all as specified and as directed |
| 14 | M & L for Mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with the including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all asspecified and directed. |
| 15 | Material and labourfor sand filling under floor or in foundation including watering and consolidation etc complete all as directed. |
| 16 | Material and labour Machine pressed precast concrete interlocking paver block any shape and size conforming to is 15658-2006 of 60 mm thickness M-35 grade with grey cement and pigment finished with coloured rubber finish on top finished over sand dust cushion of 30 mm thick complete all as specified and directed. Note : Sand cushion will be measuredand paid separately |
| 17 | Excavating in trenches, n exc 1.5m wide and n exc 1.5 m depth; for foundation, etc. or for shafts, wells, cesspits, manholes,pier holes, etc. n exc 10 sq m on plan and n exc 1.5m in depth and getting out in hard/dense soil complete all as specified and directed. |
| 18 | M&L for plain cement concrete 1:3:6 type C1 (using 20mm graded stone aggregate) as in surface channel or drain or benching in manhole complete all as specified and directed |
| 19 | M&L for forming fair finished drain or channel 30cm inner girth in cement concrete, using extra cement including forms, moulds, mitered/stoppedends etc complete all as specified and directed |
| 20 | M&L hardcore of gauge n.exc. 63mm deposited, spread and levelled in layers n.exc 15cm thick watered and rammed to a true surface for plinth protection/path complete all as specifiedand directed. |
| 21 | S&F in repair 110 mm bore PVC (SWR) pipe, single socketed in any length with rubber ring joints, fixed to walls/floor with stack clamp every one mtr apart complete all as specified and as directed. |
| 22 | Excavation in trenches for laying of cable trench, pole and stay foundation in any type of soft/loose soil not exceeding 1.5 mtr wide and not exceeding1.50 mtr deep and getting out complete all as specified and as directed. |
| 23 | Material and labour for sand cushioning with dry river sand in trenches for cushioningof underground cable line 18 including spreading, leveling, well ramming completed all as specified and directed. |
| 24 | Supplying and laying un-reinforced precast concrete cable cover, class LV, type- 1flat, size 250mm x 150mm x 40mm, complete all as specified and directed. |
| 25 | Returning filling in, including spreading, leveling watering and well ramming in layers not exceeding 25 cms thick complete all as specifiedand as directed. |
| 26 | Removing excavated materials to a distance not exceeding 50 Mtr & depositing where directed at a level not exceeding 1.5 mtr above the starting point complete all as specifiedand as directed. |
| 27 | Supply and laying in trenches or fixing in walls / poles or drawing through pipe XLPE insulated, screened,PVC bedded, galvanised steel strip or wire armoured,electric power cables ( heavy duty) with aluminium conductor, 1100 volts, grade cross sectional area 4.0 sq mm, 4.0 core including testing after laid and jointed all as specified and as directed. |
| 28 | M&L point wiring 1100 volt grade single core FRLSH PVC insulated and unsheathed cable with multistranded copper conductor 2.50 sqmm drawn in and including electrical grade PVC conduit not less than 20mm dia with IS 9537 (Part-III) 1983 marked medium grade concealed in wall/ceiling orsurface of wall/ceiling as directed including FRLSH PVC insulated unsheathed earth wire with multistranded copper conductor of size 2.50 sqmm pressed steel modular boxessunk on wall for mounting of modular switches, switch sockets, fan regulator etc including modular coverwith frame any size complete all as specified and making good disturbed surfaces for one6 A socket point controlled by one, one way switch. Note :- Cost of cable provided from sub main DB to respective switch board in rooms shall be included in the quoted point wiring rate.All switches, fan, sockets, ceiling roses and holders shall be connected to common earth dolly. |
| 29 | All as per item No 28 above but submain of size 2 x 1.5 sqmm with earth wire of size 1 x 1.5 sqmm complete all as specifiedand as directed. |
| 30 | As per item No 28 abovebut One 3 pin 5 amp socket out point on the same board with other switches complete all as specifiedand as directed. |
| 31 | All as per item Sl No 28here in before but wiring with 2.5 sqmm multi stranded cable and earth wire with copper conductor of size 2.5 sqmmfor 16 amps power point complete all as specifiedand as directed. |
| 32 | Supply and fixing for switch modular type single pole one way 6 amp 1 module 250 volts AC suitable for modular switch boxes, complete all as specified and directed complete all as specifiedand as directed. |
| 33 | Supply and fix Modular switch one way 16A, 1 module 250 volts AC suitable for modular switch boxes, complete all as specified and directed. |
| 34 | Supply and fix Modular Socket 6A 3 pin combined 2 module 250 volts AC suitable for modular switch boxes, complete all as specified and directed. |
| 35 | Supply & Fix Modular Socket 6A/ 16A3 pin combined 2 module 250 volts AC suitable for modular switch boxes, complete all as specified and directed. |
| 36 | S&F 3modulepolycarbonate box withcover plate andframe for munting of switch and socket or dummy plate if required complete all as specified and directed. (switch and sockets will be paid seperately as S & F) |
| 37 | All as item No 36 above but Modular box with modular cover plate with frame 4 module complete all as specified and directed. |
| 38 | All as item no 36 above but Modular box with modular cover plate with frame 6 module complete all as specified and directed. |
| 39 | Supply and fixing ceiling rose, surface type, three terminals 5 amps, complete all as specified and directed. |
| 40 | Supplying and fixing 20 Watt LED Tube light fittings completewith polycarbonate body including tube rod, driver with not less than 2000 Lumen O/P andI/p rated voltage 240V, 50 Hz color temp 6500 K, THD<10%, PF not less than 0.9 and surge protection upto 2.5 KV connecting with3 core 1 sqmm copper conductor cable complete all as specified and directed. |
| 41 | Supply and fix building security lightLED25 W with Lumen O/P 2500 with driver withrated voltage 240 V, 50Hz,color temp 5700 K, PF not less than 0.9 , THD< 10% including mounting GI (made out of 25 mm dia light grade pipe 0.8 m bent two shape including FI clamps nut bolts etc. complete all as specified and directed. |
| 42 | Supply and fix sheet metal enclosure single pole & neutral for 240 volts 8 way with 200 Amp rated bus bar flush /surface mounting double door, complete all as specified and directed. |
| 43 | Supply and fix MCB single pole & neutral 240 volt 32 amps 10 KA, complete all as specified and directed. |
| 44 | Supply and fix MCB single pole 240 volt 6 to 32 amps 10 KA, complete all as specified and directed. |
| 45 | Earthing complete with galvanized street earth plate electrode 600x600x6mm thick buried directly in ground (earth plate not less than 2.25mtr deep below normal ground level) with top edge of the plate not less then 1.50 mtr.below the normal ground level connected to galvanized earth lead wire 4.00 mm dia by means of bolts nuts check nuts & washer of galvanized iron or steel all as shown in electrical plate No 5 connected to earthing test point all as specified and testing on completion including the material and labour for :-(a) Excavation and earth work or drilling hole for electrode in any type of soil (b)PCC pit in cement concrete 1:2:4 TYPE B-1 (.c)Pre cast RCC cover with suitable handle 40mm thick in PCC 1:2:4 reinforced with welded steel wire fabric weighting not less than 1.87 Kg/sqmm (d)Funnel with watering pipe of GI 20mm nominal bore medium grade and Aluminum lugs etc all as specified.(e)15mm nominal bore medium grade GI protection pipe up to 7.50 meter long for protection of earthing lead.(f)Requisite quantity of charcoal and common salt (g) Connection to earthing test point and testing on completion. |