Sales : +91-777 804 8217
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 05-03-2026 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 12-03-2026 |
| 2 | 23-02-2026 | DATE EXTENDED | Date | 05-03-2026 |
| 3 | 23-02-2026 | DATE EXTENDED | Date | 05-03-2026 |
| Sl. No. | Item Description |
| 1 | B/R PORTIONExcavation in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. n exc 10 sqm on plan and n exc 1.5m in depth and getting out in any type of soil complete as specified and as directed. |
| 2 | M & L for PCC (1:4:8) type D-2 (using 40mm graded stone aggregate) as in foundation, filling and mass concrete all as specified and as directed. |
| 3 | M & L for use and waste of timber as in formwork to sides of concrete foundations, footings, bases of columns raft and raft beams sides and soffits of foundation and plinth beam and similar work vertical or to batter for rough finished surfaces of concrete flat all as specified and as directed. |
| 4 | M & L for use and waste of timber as in formwork to sides of pillars, posts, struts, piers, column and stanchions for rough finished surfaces of concrete square, circular, rectangular on plan or polygonalfor rough finished surfaces of concrete flatall as specified and as directed. |
| 5 | M & L for use and waste of timber as in formwork flat to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc. for rough finished surfaces of concrete flat complete all as specified and as directed. |
| 6 | M & L for use and waste of timber as in formwork to chullah hoods, chajjas, troughs and similar items including edges, flat rough finished surfaces of concrete complete all as specified and as directed. |
| 7 | M & L for use and waste of timber as in formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping)flat rough finished surfaces of concrete complete all as specified and as directed. |
| 8 | M & L for MS TMT bars 10 mm dia and over cut to length bent to shape required including cranking bending spirally for hoping columns and binding with mild steel wire annealed not less than 0.9 mm dia or securing with clips complete all as specified and as directed. |
| 9 | M & L for MS TMT bars 5mm dia and over upto and inclduing 10mm dia in stirrups, spacers and binders complete all as specified and as directed. |
| 10 | M & L for RCC M-30, design mix (using 20 mm graded stone aggregate) as in foundation, footings and plinth beams etc complete all as specified and as directed. |
| 11 | M & L for RCC M-30, design mix (using 20 mm graded stone aggregate) as in Columns complete all as specified and as directed. |
| 12 | M & L for RCC M-30, design mix (using 20 mm graded stone aggregate) as in Beams, cantilevers, bressumers, lintels over1.5m span complete all as specified and as directed. |
| 13 | M & L for RCC M-30 design mix (using 20mm graded stone aggregate) as in chajjas complete all as specified. |
| 14 | M & L for RCC M-30 design mix (using 20mm graded stone aggregate) as in Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and as directed. |
| 15 | M & L precast cement concrete (1:3:6)type C-1 (using 20 mm graded stone aggregate) block masonrywith solidblocks, exc. 10 cm in width and setting in CM (1:6) complete all as specified and as directed. |
| 16 | M & Lfor rendering 15mm thick in cement mortar(1:4) on externalfair faces of solid block or concrete surfaces finished even and smooth without using extra cement complete all as specified and directed. |
| 17 | M & Lfor rendering 15mm thick in cement mortar(1:6) on fair faces of solid block or concrete surfaces finished even and smooth without using extra cement complete all as specified and directed. |
| 18 | M & L for rendering 5mm thick in cement mortar(1:4) onfair faces of solid block or concrete surfaces of ceiling finished even and smooth without using extra cement complete all as specified and directed. |
| 19 | M & L forproviding 75 mm thick plain cement concrete (1:2:4), type B-2 (using 40mm graded stone aggregate) as in plinth protection complete all as specified and as directed. |
| 20 | M & L for Non skid Ceramic cloured tiles7 to 8 mm thick (square/ rectangular) area of each tile exc 0.18 sqm but not exc 0.36 sqm, in floors etc., set and jointed in neat cement slurry and pointed in white or coloured over and including screed bed or bedding layer 15 mm thick in CM (1:6) complete all as specified and directed. |
| 21 | M & L for glazed ceramic tiles 300mm x 200mm x 6 to 7mm thick in vertical surfaces set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and directed. |
| 22 | Returning, Filling in, including spreading, leveling, watering amd well ramming in layers not exc 25cm in soils complete all as specified and as directed. |
| 23 | Removing excavated materials to a distance n.exc 50m and depositing where directed at a level n.exc 1.5m above the starting point complete all as specified and as directed. |
| 24 | S & F vitreous china wash basin white, flat back, size 550 x 400mm excluding taps, chain and plug and porcelain stopper but including brackets, waste couplings 32mm dia, cutting for and pinning in ends of brackets or errecting stand complete all as specified and directed. |
| 25 | S & F Pillar taps fancy type, cast copper alloy, with capstan heads, chromium plated, screwed down high pressure, with or without lettered \"Hot\" or \"Cold\" with long screwed shanks and fly-nuts, screwed for 15mm diairon bore pipe and fixed complete all as specified and directed. |
| 26 | S & F angle stop cock 15mm bore, fancy type, chromium plated (concealed type) screwed down, high pressure with crutch or butterfly handle, screwed both ends for iron pipe or unions and fixed complete all as specified and directed. |
| 27 | S & F 32mm size waste couplings of PTMT (half or full threaded) (minimum weight 32mm- 45gms) complete all as specified and directed. |
| 28 | S & F towel rail 450mm long of Stainless Steelfixed with and inlcuding chromium plated brass screws and wooden / plastic cleats (minimum weight 170gms) complete all as specified and directed. |
| 29 | S & F tubes, medium grade 15mm dia bore galvanized with all fittings and fixed complete to walls and ceiling or laid in floors complete all as specified and directed. |
| 30 | S & F 20mm dia stainless steel curtain rod with all types of bracket to required length complete all as specified and directed. Note : Rate included for side bracket for fixing complete |
| 31 | S & F 75mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors complete all as specified and directed. |
| 32 | S & F 75mm bore PVC (SWR) bends any radius complete all as specified and as directed. |
| 33 | M & L for preparing new plastered surfaces of wall and applying two coats of OBD over primer on decorated wall surfaces of any description, complete all as specified and directed. |
| 34 | M & L for preparing new/ old plastered surfaces of wall and applying two coats ofanti fungal exterior acrylic emulsion on wall surfaces of any description complete all as specified and directed. |
| 35 | S & F anodised aluminium frame for doors, windows, ventilators with one or more rebates including joining cleat for fixing, hinges, tower bolts, handle etc. complete all as specified and directed. |
| 36 | S & F anodised aluminium door shutters, aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber neoprene packing, handles 2Nos in each door, hinges, anodies aluminium snap beading screws etc. complete all as specified and directed. |
| 37 | S & F anodised aluminium window and ventilator shutters, side hung type without sash bars, aluminium section weighing 0.55 kg/m including necessary joininig cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittings such as peg stays 150mm long (1 No.), hinges type B-21 100mm long (2 No.) suitable handle (1 No.) complete all as specified and directed. |
| 38 | S & F aluminium (Dia cast) body Door closer hydraulically regulated, designation No. 3, universal type, suitable for door shutters of 851 to 1000 mm in width and of weight between 61 to 80 kg and fixed complete all as specified and directed. |
| 39 | S & F 4mm thick sheet glass, ordinary quality and glaing with oil putty in square n.exc 0.5 sq.m in each pane complete all as specified and directed. |
| 40 | S & F roof trusses (framed), trussed, purlins, crane grantries, rail and fastenings and heavy bracket framing (beam, tee,angle, channel, or flat section ) including bracket, etc complet Fe 410-W (Gde-E-250) quaility A all as specified and as directed. |
| 41 | S & F pre painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with selftapping screws complete all as specified and directed. |
| 42 | S & F pre- painted galvalume aluminium zinc coating GI based plain steel sheet 0.50mm thick of any colour having tensile strength of 550 mpa as in roof covering/ cladding to wall, fixed with self tapping screws complete all as specified and directed. |
| 43 | S & F MS work as in wind ties, etc. incl cutting, drilling and made to shape as required complete all as specified and as directed. |
| 44 | M & L for preparation of new or previously untreated steel surfaces of any description over10cm width or girth not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide primer all as specified and as directed. |
| 45 | M & L for 18/19mm thick Prelaminated particle board, exterior grade, prelaminated one side with decorative choice lamination & other side balancing white lamination, fixed with screws to timber frame work complete all as specified and directed. |
| 46 | S & F Continuous (piano) hinges, brass, bright finish or electrogalvanised width of flap 30mm when open complete all as specified and directed. |
| 47 | S & F 100mm Extruded brass handles, fabricated type polished complete all as specified and directed. |
| 48 | S & F aluminium anodised snap grid frame (with minimum 15 micron uniform anodic coating) size of 600 x 600 mm consisting of Tee/Angle section, size 40x40x2 mm thick as approved make conforming to IS-733 in frames of false ceiling including aluminium cleats with necessary CP brass/stainless shunk screws.aluminium perimeter angles fixed to wall wooden frame at centre to centre and fixing frame to level adjusting anchors 6 mm dia GI wire hook in Tee members at 1.5 m Centre to Centre fixed to steel truss orroof complete all as specified and directed |
| 49 | M & L for fixing in position 4 mm thick Non Asbestos designer ceiling board of size 595x595 mm as per manufacturer\"s specification complete all as specified and directed. |
| 50 | M & L for 20mmthick Granite (of any type) work (table rubbed and polished) for wall lining (veneering to wall) 12mm thick in cement mortar (1:3) and pointing with white cement (1:2) using marble dust with admixture of pigment to match with shade of granite complete all as specified and directed. |
| 51 | Surface excavation n.exc.30cm deep and avg 15 cm getting out in any type of soil complete all as specified and directed. |
| 52 | Removing excavated material(soil) to a distance exc.50m and n.exc.100m and depositing where directed at a level n.exc.1.50m ht above the starting point complete all as specified and directed. |
| 53 | M & L for hard core of broken stone or boulders of gauge n.exc.63mm, deposited, spread, levelled in layers n.exc.15cm thick, watered and rammed to a true surface complete all as specified and directed. |
| 54 | M & L for providing 100mm thick PCC (1:4:8), type D-2 (using 40mm graded stone aggregate) as in sub base complete all as specified and directed. |
| 55 | M & L for 15mm thick screed bed or bedding layer in CM (1:4) as in base to floor finish complete all as specified and directed. |
| 56 | M & L for precast chequered cement concrete tiles designer type Rubber moulded with white cement and pigments, 30cm x 30cm x 25mm thick, set, jointed in neat cement slurry and pointed in white or coloured cement to match as in floors complete all as specified and as directed. |
| 57 | M & L for providing cement concrete type C-1, (1:3:6) (using 20mm graded stone aggregate) as in coping benching, bed plate, including necessary form work complete all as specified and directed. |
| 58 | Taking down of cement plaster of any description or thickness/chipping of cement concrete in any situation from brick or concrete surface including raking out of joints, hacking for key scrubbing down with water to receive new plaster complete all as specified and directed. |
| 59 | M & L for rendering 5mm thick on fair faces of brick work or concrete surfaces on ceilings finished even and smooth (without using extra cement) in CM (1:3) complete all as specified and directed. |
| 60 | M & L for preparing old plastered surfaces of wall and applying one coat of oil bound distemper complete all as specified and as directed. |
| 61 | M & L for preparing new plastered surfaces of ceiling and applying two coats of oil bound distemper over a coat of primer, complete all as specified and as directed. |
| 62 | M & L for preparing old plastered surfaces of ceiling and applying one coat of oil bound distemper complete all as specified and as directed. |
| 63 | Taking down chowkats or frame with shutters (without taking off shutters from the frame), n.exc 1.5 Sqm each complete all as specified and as directed. |
| 64 | Taking down chowkats or frame with shutters(without taking off shutters from the frame),exc 1.5 Sqm but n.exc 4.0 Sqm each complete all as specified and as directed. |
| 65 | Taking down shutters of any description exc 1.0 Sqm and n exc 2.0 Sqmeach all as spcified and as directed. |
| 66 | S & F 35mm thick, 2nd class HW plain, framed, panelled shutters (any number of panels), with panels of timber flat on both sides (feather edged), or of veneered particle board medium density, wood particle board with commercial veneers ; supplied and fitted to chowkat all as specified and as directed. |
| 67 | S & F 2nd class HW, 35mm thick glazed and skeleton shutters, open rebatedand prepared to receive glass or gauge etc., without sash bars, edges of framing plain chamfered or rounded, fitted with cut and mitred beads for screwing glass / gauge etc., sizes of members of shutters as specified in SSR Part-I, section 8 clause 8.24 (a) all as specified and as directed. |
| 68 | S & F 4mm thick figured glass, pin head type and glazing with oil putty in square n.exc 0.5 Sqm in each pane complete all as specified and directed. |
| 69 | S & F aluminium alloy wire cloth 0.45mm nominal dia of wire and average width of operature 1.40mm and fixed with aluminium wire staples all as specified and directed. |
| 70 | S & F solid PVC door frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with 19 x 19mm MS square tube and 1.2mm wall thickness complete all as specified and as directed. |
| 71 | S & F solid panel PVC door shutter 30mm thick (style) consisting of frame made out of MS tube for top and bottom rail.MS frame shall be covered with heat moulded plain colour PVC \"C\" channel having a PVC sheet strip of 20mm width stuck inside with a solvent cement for stiles and plain colour PVC sheet for top rail, lock rail and bottom rail on either sides and as gap inserts for top and bottom rail paneling of plain colour PVC sheets to be fitted in the MS frame welded / sealed to the stiles and rails with suitable PVC sheet beading and jointed together with solvent cement as per specification and drawing complete all as specified and as directed. |
| 72 | S & F Stainless Steel butt hinges 100mm long, medium weight cold rolled, fixed to timber frame work of doors complete all as specified and directed. |
| 73 | S & F Stainless Steelbutt hinges 75mm long, medium weight cold rolled, fixed to timber frame work of doors complete all as specified and directed. |
| 74 | M & L extruded aluminium alloy handles 150mm, fabricated type, anodized complete all as specified and directed. |
| 75 | M & L extruded aluminium alloy handles 100mm, fabricated type, anodized complete all as specified and directed. |
| 76 | M & L aluminium anodized barrel tower bolt of extruded section length of bolt 150mm complete all as specified and directed. |
| 77 | M & L aluminium anodized barrel tower bolt of extruded section length of bolt 100mm complete all as specified and directed. |
| 78 | M & L for Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed complete all as specified and as directed. |
| 79 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but not hacking), removing serviceable tiles away from site and rubbish off the premises complete all as specified and as directed. |
| 80 | S & F non skid coloured ceramic tiles 300mm x 300mm x 7 to 8mm thick in floors., set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and as directed. |
| 81 | M & L for rendering 10mm thick cement plastered as backing coat for wall on fair surfaces of brick in cement mortar (1:3) to receive wall tiles complete all as specified and as directed. |
| 82 | S & F glazed coloured ceramic tiles 300mm x 450mm x 6 to 7mm thick in vertical surfaces set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and as directed. |
| 83 | Demolition of cement concrete (un-reinforced) in ground floors and pavingsexceeding15 cm thickness above ground floors complete all as specified and directed. |
| 84 | M & L for providing 75 mm thick plain cement concrete (1:3:6), type C-2 (using 40mm graded stone aggregate) as in plinth protection complete all as specified and as directed. |
| 85 | M & L for providing 40mm thick cement concrete type B-0, (1:2:4) (using 12.5mm graded aggregate) as in flooring finishing cement concrete surface even and smooth without using extra cement complete all as specified and as directed. |
| 86 | M & L for Glass dividing strips, 3 mm thick 38mm wide as in flooring complete all as specified and as directed. |
| 87 | M & L for providing 100mm thickcement concrete (1:4:8) type D-2 (using 40mm graded stone aggregate) as in sub base complete all as specified and as directed. |
| 88 | M & L for coloured chequered cement concrete tiles 30cm x 30cm x 25mm thick, set in floors etc., laid over and including 20mm thick screed bed in cement mortar (1:6) set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and directed. |
| 89 | Demolition of cement concrete (reinforced) of any description and in any position not otherwise specifically provided for complete all as specified and directed. |
| 90 | S & F in repair European type WC (Pedestal Pattern) complete inlcuding pedestal pan and trap inlcuding connection to drain, flushing pipe, seat cover (excluding fixing bolt, flushing cistern complete all as spefcified and directed. |
| 91 | S & F in repair PVC valve less, syphonic action type flushing cistern, 10 litres, low level, white with inlet ball valve, float and handle inlcuding brackets complete all as specified and directed. |
| 92 | S & F in repairs PVC connections 15mm size 600mm long with PTMT nuts complete all as specified and directed. |
| 93 | S & F in repair Pillar taps fancy type, cast copper alloy, with capstan heads, chromium plated, screwed down high pressure, with or without lettered \"Hot\" or \"Cold\" with long screwed shanks and fly-nuts, screwed for 15mm diairon bore pipe and fixed complete all as specified. |
| 94 | S & F in repairs angle stop cock 15mm bore, fancy type, chromium plated (concealed type) screwed down, high pressure with crutch or butterfly handle, screwed both ends for iron pipe or unions and fixed complete all as specified and directed. |
| 95 | S & F in repairs bib tap 15mm bore, fancy type, cast copper alloy, chromium plated, screwed down high pressure with crutch or butterfly screwed for iron and fixed complete all as specified and directed. |
| 96 | S & F in repair towel rail 450mm long of Stainless Steelfixed with and inlcuding chromium plated brass screws and wooden / plastic cleats (minimum weight 170gms) complete all as specified and directed. |
| 97 | S & F in repair 600 x 450mm bevelled edge mirror of selected quality glass mounted on 6mm thick AC building board or commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers complete all as specified and directed. |
| 98 | Taking up or down steel water tubing and connection 15mm dia complete all as specified and as directed. |
| 99 | S & F in repair 110mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors complete all as specified. |
| 100 | S & F in repairs 110mm bore PVC (SWR) bends any radius complete all as specified and as directed. |
| 101 | S & F in repairs 75mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors complete all as specified. |
| 102 | S & F in repairs 75mm bore PVC (SWR) bends any radius complete all as specified and as directed. |
| 103 | Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed. |
| 104 | S & F framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other coveringm doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete all as specified and as directed. |
| 105 | S & F framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165 complete all as specified and as directed. |
| 106 | M & L for sweeping & cleaning down with water to remove dust & providing APP based polymeric membrane minimum weighing 3kg/sqm and minimum 3mm thick reinforced with polyster non woven fabric (wt. not less than 150 gms/sqm) laid on primed surface by forced application, shall be laid over hot blown bitumen grade 85/25 conforming to IS 702 @ 1.2 kg per Sqm over a coat of bituminous primer complete all as specified and directed as per manufacturer\"s instructions. |
| 107 | M & L for two coats of heat resistant paint over a coat of primer including preparation of surfaces over 10 cm width or girth not otherwise described complete all as specified and as directed. |
| 108 | E/M PORTIONM & L for point wiringconcealed / casing capping on walls and surface on ceiling complete with FRLS PVC insulated unsheathed 1100 Volts grade, conforming to IS-694, 1.5 Sq mm (nominal area) multi stranded copper conductor cable drawn though in and including non metallic medium grade rigid PVC conduit/casing capping heavy grade accessories, ISI marked, 19/20 mm dia including all accessories, concealed in/surface on wallsby cutting chases using machine and making good the disturbed surface, with and including suitable boxes ,switch plates of suitable make and 1.5 sq mm copper earth continuity wire connected to earth dolly for One light point controlled by one switch completeall as specified and as directed. |
| 109 | Descrption all as per Item No 108.00 above but One fan point controlled by one switch completeall as specified and as directed. |
| 110 | Descrption all as per Item No 108.00 above but One socket 5 Amps on same board completeall as specified and as directed. |
| 111 | Descrption all as per Item No 108.00 above but One socket 5 Amps on independent board completeall as specified and as directed. |
| 112 | Description all as per item No. 108.00 abovebut with 4 Sqmm cable for 3 pin 15 Amps socket point controlled by one switch on independent board and 4 Sqmm copper conductor green in colour as earth continuity conductor complete all as specified and directed by Engineer-in-Charge. |
| 113 | S & FSwitch piano, flush type single pole, one way 5 Amp complete all as specified and directed. |
| 114 | S & Fsocket outlet 2 in 1,3 pin 5 Amps complete all as specified and directed. |
| 115 | S & F switch socket combination outlet 2 in 1,3 pin 5 Amps flush type complete all as specified and directed. |
| 116 | S & F Switch Socket combination 2 in 1, 3 pin, 5 and 15 Amp flush type universal complete all as specified and directed. |
| 117 | S & F Ceiling rose PVC/ Polycarbonate insulated body with three terminals complete all as specified and directed. |
| 118 | S & F wall mounted LED 18/20 watts with out put of 1800 lumens , boxtype (decorative) light fitting, 230 volts with extruded aluminium heat sink provided for efficient heat dissipation and intregrated electronic driverconnector block etc complete with all accessories internally pre wired andnecessary mounting arrangements, provision of new 3 core multistrandedcopper conductor of size 23/0.193 from ceiling rose to fitting including LED tube 4\" x 18 watts including removal old existing unsv tube light fitting complete all as specified and as directed. |
| 119 | S & F Ceiling fan Complete with blades, down rod, and all accessories, 230V , 1200mm sweep Min Air Delivery 210 CFMwith Five star rated with Brushless direct current motor (BLDC) all as specified and directed . |
| 120 | S & FEnergy saving new generation 10 watts LED bulk head fitting IP 65 luminaire with opel diffuser pre wired andnecessary mounting arrangements , provision of new 3 core multistrandedcopper conductor of size 23/0.193 from ceiling rose to fitting including LED bulb and removal old existing unsv tube light fitting complete all as specified and as directed by Engr in Charge. |
| 121 | M & L for submain wiring withsingle core PVC insulated FRLS multistranded copper conductor cable of size 2x 2.5 Sqmm drawing into and includingrigid non metallic PVC conduit, medium grade not less than 20mm dia ISI marked ivory colour with all conduit fittings and fixing accessories and 1x1.5 Sqmm FRLS multistranded copper conductor cable as continuous earth wire and removal old existing unsv complete as directed by Engr in Charge |
| 122 | M & L for cutting chases for concealed conduitpoint wiring,sub main wiringand sinkings for boxes but not exeeding 10 cm girth and making good to walls,floors with 1:3 cement mortar and applywhite wash or distempermatching with existing colour as directed by Engr in Charge |
| 123 | S & F in replacement sheet metal enclosure MCBDBTPN4 way with 200 Amps rated bus bar 240 volts double door with magnitic locking system including refixing / fixing of incomming & outgoing MCBs and making smooth the wall surfaces and removal old existing unsvcomplete all as specified and directed. |
| 124 | Supply & fixing MCBs of following rating and taking out MCBs of any rating. (a) MCB SP 6 to 32 Amps 240V 10 KA.\"C\" Series complete all as specified and directed. |
| 125 | (b) MCB DP 32 Amps 240V 10 KA.\"C\" Series complete all as specified and directed. |
| 126 | M & L for earthing with galvanised steel earth plate electrode 60cmx60cmx6mm burriedearth pit not less than 2.25m depth below normal ground level with to edge of the plate vertically to depth of not less than 1.5 m below ground level connected to & including Galvanised earth wire 4 sqmm by mean of GI bolts & nuts etc with provision of char-coal and salt etc all as per electrical plate No-3 of SSR-2010including RCC cover and MS angle iron frame, watering with GI pipe 20 mm dia (medium grade) & MS funnel, concrete pit including excavation and earthwork and testing on completion etc. complete all as specified and directed by Engineer-in-charge.Note :(i).Refilling of the earth pit shall be carried out with black cotton soil.(ii)GIwire 4.0mm dia & GI protection pipe upto 7.5 m length will be measured under this item.(iii) On testing after completion, if the desired earth resistance is not obtained the earthing will be redone to the entire satisfaction of Engr-in-Charge at no extra cost |
| 127 | S & F tubes, CPVC pipe 25mm dia bore with all fittings and fixed SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified and directed. |
| 128 | S & F CPVC Gate valve, for CPVC pipe 25 mm bore dia complete all as specified and directed. |
| 129 | S & L XLPE, insulated, armoured, heavy duty, electric cable of cross sectional area of 2 Core x 16 Sq mm with stranded aluminium conductors, 1100 volts grade, laid in tranches/fixing on wall/poles or passing through pipe, including connecting up with suitable glands, lugs, nuts and bolts wherever required and testing on completion, with GI protections pipes, complete all as specified and as directed. |
| 130 | S & F for DWC pipe double wall corrugated pipes conforming to IS-14930 Part-II with IP Protection of IP-67 having outer dia 50 mm and inner dia of 38 mm with necessary couplers, bends etc for protection of LT cable all as specified and directed. |
| 131 | M & Lfor light/ fan point wiring complete with 1.5 Sqmm PVC insulated unsheathed single core multi stranded copper conductor 1100 V grade drawn through in and including 20 mm dia steel conduit concealed on walls/on ceiling and terminated to flame proof switch including 1.5 Sqmm PVC insulated copper conductor cable as earth continuity conductor and connecting to common earth dolly complete all as specified and directed. |
| 132 | M & L for point wiring complete with 2.5 Sqmm PVC insulated unsheathed single core multi stranded copper conductor 1100 V grade drawn through in and including 20 mm dia steel conduit concealed on walls/on ceiling and terminated to flame proof 16 Amp switch socket combination suitable for fixingincluding 2.5 Sqmm PVC insulated copper conductor cable as earth continuity conductor and connecting to common earth dolly complete all as specified and directed. |
| 133 | S & F LED light fitting 1x16 Watt flame proof, CMRI certified recommended for gas/ vapor group of IIA & IIIB, Zone 1 & 2 and IP 65 protection with die cast aluminum housing with heat resistant toughened glass with LED tube light fixtures driver complete all as specified and as directed. |
| 134 | S & F flame proof exhaust fan 300mm sweep 1400 RPM complete all as specified and as directed. |
| 135 | S & F switch flame proof rotary type with termination box in LM6, 16A, single pole 250V complete all as specified and as directed. |
| 136 | S & F flame proof switch socket & plug combined in LM6 cable termination box in LM6, 16A, 250V, 2P + earth complete all as specified and as directed. |
| 137 | M & L for submain wiring with 2 runs of single core 4 Sqmm PVC insulatedunsheathed cable 1100 volts grade and one run of earth wire 2.5 Sqmmwith multistrandedcopperconductor drawn through and including metallic rigid steel conduit and steel accessories fixed on wall / roof /floor etc complete all as specified and as directed. |
| 138 | S & F in replacement sheet metal enclosure MCBDBSPN12 way with 200 Amps rated bus bar 240 volts double door with magnetic locking system including refixing / fixing of incoming & outgoing MCBs and making smooth the wall surfaces complete all as specified and as directed. |
| 139 | Supply only MCB SP 6 to 32 Amps, 240V, with breaking capacity 10 KA,\"C\" Series complete all as specified and as directed. |
| 140 | Supply only MCB DP 32 Amps,240V, with breaking capacity 10 KA,\"C\" Series complete all as specified and as directed. |
| 141 | Dismantling and taking out old unserviceable earthing and M & L for earthing with galvanised steel earth plate electrode 600 x 600 x 6mm burriedearth pit not less than 2.25m depth below normal ground level with top edge of the plate vertically to depth of not less than 1.5 m below ground level connected to & including Galvanised earth wire 4 Sqmm by mean of GI bolts & nuts etc with provision of charcoal and salt etc all as per electrical plate No-3 of SSR 2020including RCC cover and MS angle iron frame, watering with GI pipe 20 mm dia (medium grade) & MS funnel, concrete pit including excavation and earthwork and testing on completion etc. complete all as specified and directed.Note :(i)Refilling of the earth pit shall be carried out with black cotton soil.(ii) GIwire 4.0mm dia & GI protection pipe upto 7.5 m length will be measured under this item. (iii) On testing after completion, if the desired earth resistance is not obtained the earthing will be redone to the entire satisfaction of Engr-in-Charge at no extra cost |
| 142 | Supply and laying XLPE, insulated, armoured, heavy duty, electric cable with stranded aluminium conductors, 4 Core x 16 Sq mm, 1100 volts grade, laid in tranches /fixing on wall/ poles or passing through pipe, including connecting up with suitable glands, lugs, nuts and bolts wherever required and testing on completion, with GI protections pipes, complete all as specified and as directed. |
| 143 | S & F single pointed air termination aluminium rod 12mm dia 300mm long complete all as specified and as directed. |
| 144 | S & FAluminium strip 25mm x 3 mm complete with saddles and fixing screws for fitting the strip complete all as specified and as directed. |
| 145 | Supply & install GI strip 25 x 4 mm buried in ground for earth continuity from earth electrodeto test point terminal block complete all as specified and as directed. |
| 146 | Supply & layingGI pipemedium grade40mm dia including all connecting accessories complete al as specified and as directed. |
| 147 | S & F testpoint terminal block made of gun metal of phosphor bronze of size 75mm x 75mm x 25mm drilled and screwedincluding 3 Nos 8mm dia 25mm long hexagonal head screw of brass fixed to wallcomplete all as specified and as directed. |
| 148 | M & L for Earthing complete with galvanised steel earth plate electrode 600 x 600 x6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to galvanised iron strip 25 x 4mm as earthing leadby means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 5 connected to earthing test pointall as specified or indicated including testing on completion complete all as specified and directed.Note : On testing after completion, if the desired earth resistance is not obtained the earthing will be redone to the entire satisfaction of Engr-in-Charge at no extra cost. |
| 149 | S & F rotational moulded polyethlene water storage tanks two layer capacity of 1000 ltr (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part-Icomplete all as specified and as directed. |
| 150 | M & L for cutting ofexistingold GI pipes 25 & 50 mm dia , insertion of fittings such aselbow, Tees, nipples, reducer , dummy, plugs etc as required upto 50 mm bore as per directed by Engr-in-Charge.(Note : Fittings will be measured and paid seperately under relevent item of schedule) |
| 151 | Supply, laying on wall/ ceiling /floor GI pipe of 25 mm dia medium grade including all fittings such as bends, elbow, Tee, short length , socket , union etc complete including testing complete all as specified and as directed. |
| 152 | M & L for Gun metal gate valves 25 mm dia including fittings etc complete all as specified and as directed. |
| 153 | M & L cutting of road, hard standing made of concrete or premix carpet, WBM, soling and morrum filling for laying of pipeline all as directed and making good the road/hard standing by using all old/new materials and with PCC (1:2:4) etc, required to match with the existing surface complete all as specified and as directed. |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail