| 1 | Notes : Please refer schedule \"A\" notesbefore quoting the tender.JOB \"A\" (B/R WORKS) |
| 2 | Demolition of reinforced cement concrete as in roofs, floors (other than ground floors), beams, staircases, landing, chajjas and similar suspended works complete all as specified and as directed. |
| 3 | Separating, scraping and cleaning of reinforcement (Demolition of concrete measured separately) complete all as specified and as directed. |
| 4 | Demolition ofbrickwork or stone/ boulder masonry, built in cement or cement lime mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified and as directed. |
| 5 | Taking down chowkhats or frames or rolling shutter area exc 1.5 sq. m but n exc 4 sq. m each with shutters (without taking off shutters from the frame) complete all as specified and as directed. |
| 6 | Taking down chowkhats or frames area nexc 1.5 sq. meach with shutters (without taking off shutters from the frame) complete all as specified and as directed. |
| 7 | Removing building materials etc. to a distance n exc 1.5 km or under, beyond the lead included in the rates, including loading, unloading and stacking at the destination complete all as specified and as directed. |
| 8 | Surface excavation n exc 30 cm deep and avg 15 cm deep and getting out in any type of soil complete all as specified and as directed. |
| 9 | Excavation in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out hard dense soil complete all as specified and as directed. |
| 10 | Excavation in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out soft disintegrated rock complete all as specified and as directed. |
| 11 | Excavating in trenches, n exc 1.5 m wide andexc 1.5 mand n exc 3 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out soft disintegrated rock complete all as specified and as directed. |
| 12 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm in harde dense soil complete all as specified and as directed. |
| 13 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm in soft disintefgrated rock complete all as specified and as directed. |
| 14 | Removing excavated material n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point for soil complete all as specified and as directed. |
| 15 | Removing excavated material n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point for soft disintegrated rocks complete all as specified and as directed. |
| 16 | M&L for Cement concrete in foundations, filling and mass-concrete ,1:2:4 (using 40mm graded stone aggregates) complete all as specified and as directed. |
| 17 | M&L for RCC M-30 (Design mix) as in foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc; basement slabs and mass concrete complete all as specified and as directed. |
| 18 | M&L for RCC M-30 (Design mix) as in Columns, pillars, piers, posts and struts complete all as specified and as directed. |
| 19 | M&L for Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter complete all as specified and as directed. |
| 20 | M&L for Formwork to sides of pillars, posts, struts, piers, columns and stanchions complete all as specified and as directed. |
| 21 | M&L for treating the bottom and sides of excavation at the rate of 5 litres of emulsion per square metre of surface area complete all as specified and as directed. |
| 22 | M&L for treating the backfill in contact with foundation at the rate of 7.5 litres of emulsion per square metre of vertical surface (Area of the sub structure in contact with backfill to be measured) complete all as specified and as directed. |
| 23 | M&L for treating the top surface of filled earth at the rate of 5 litres of emulsion per square metre of surface complete all as specified and as directed. |
| 24 | M&L for treating the soil under plinth protection at the rate of 5 litres of emulsion per square metre of surface area complete all as specified and as directed. |
| 25 | Treating the soil along with external perimeter of building at the rate of 2.25 litre of emulsion per metre of the perimeter wall |
| 26 | S&F TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed. |
| 27 | All as per BoQ Serial Item No.26.00 above but 6 mm to 8 mm complete all as specified and as directed. |
| 28 | All as per BoQ Serial Item No.26.00 above but 5mm dia and over upto and including 10mm dia as in stirrups, spacers and binders complete all as specified and as directed. |
| 29 | M&L for Pre-cast cement concrete Type C1 (1:3:6) (using 20mm graded stone aggregates) block masonry with solid blocks, exc. 10 cm in width and setting in mortar 1:6, complete all as specified and as directed. |
| 30 | M&L for RCC M-30 (Design Mix) as in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and as directed. |
| 31 | M&L for RCC M-30 (Design Mix) as in beams, cantilevers, bressummers, lintels over 1.5m span complete all as specified and as directed. |
| 32 | M&L for formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping) complete all as specified and as directed. |
| 33 | M&L for formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including sup- ports, overhangs, etc. also splays between floors and beams, etc complete all as specified and as directed. |
| 34 | M&L for Hardcore of broken stone or boulders; gauge n exc. 63 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface complete all as specified and as directed. |
| 35 | M&L for 75 mm thick PCC Cement concrete type D- 2, 1:4:8 (using 40mm graded stone aggregates) as in sub base, etc complete all as specified and as directed. |
| 36 | M&L for 100 mm thick PCC Cement concrete type B- 2, 1:2:4 (using 40mm graded stone aggregates) as in floorings; finished even and smooth without using extra cement complete all as specified and as directed. |
| 37 | M&L for 2mm thick polymer natural/ synthetic anti static flooring fire retardant compression moulding conductive flooring having electrical residence floor surface to earth between 50 kilo Ohms to 2.5 mega Ohms measured with wet etectrode in accordance with details contained in STEC pamphlet No 7; fixed over and including copper strips grid work using 50mm x 0.5mm thick forming 0.9 sqm grid, joints of copper strips, brazed on the existing surface including cleaning & preparation of surface by pasting with suitable adhesive; copper grid to be provided with diagonal earthing; earthing resistance shall not exceed one ohm; copper strip work shall be fixed to the existing floor at the 0.6m to 0.9m all per manufacturer\"s instructions complete all as specified and as directed. |
| 38 | M&L for 2 mm thick aluminium sheet, plain, as in wall cladding, steel gates, doors etc and similar work, cut to size, holes punched; including round headed screws, clout nails or rivets and fixed to wood or steel framing with plain 40 mm lap joints with riveted or welded seams, including bending or turning up, mitred angles, etc. as required complete all as specified and as directed. |
| 39 | M&L for applying oil bound primer @ 0.40 Litre/Sqm (manufactured by the same agency as that of APP) with density of 0.87 to 0.89 Kg/Litre at 25 degree celsius on the prepared dry roof surface and M&L for laying 4mm thick APP modifed water proofing membrane reinforced with non-wooven polyster matt with physical properties; laying shall got be done through authorized applicator of manufacturer; M&L for providing over the membrane finishing with two coats of solar reflective bituminous aluminium paint @ 0.10 Kg/sqm as prescribed by manufacturer of membrane including 10 years guarantee on prescribed form all as per manufacturers instructions and complete all as specified and as directed. |
| 40 | Supply only liquid water proofing compound mixed with cement concrete/ cement plaster as per manufacturer\"s instruction complete all as specified and as directed. |
| 41 | M&L for 75 mm thick PCC Cement concrete type C- 2, 1:3:6 (using 40mm graded stone aggregates) as in plinth protection, etc complete all as specified and as directed. |
| 42 | M&L for 60mm thick factory made chamfered edge cement concrete paver block of M-35 grade with approved colour, design & pattern as in footpaths, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of fine sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand; complete all as specified and as directed. |
| 43 | JOB \"A\" (EM WORKS) |
| 44 | M&L for Submain wiring with single core 1100 volts 1.5 sqmm two runs FRLSH size PVC insulated PVC unsheathed stranded copper conductor using color code drawn through and including stove steel enameled conduit 20 mm dia with accessories like flame proof bend, flame proof juntion box etc and including 1.5 sqmm PVC insulated PVC unsheathed FRLSH copper conductor in cable for continuous earth continuty conductor by using green colour to common earthand connecting to earth point and connecting to earth dolly complete all as specified and as directed. |
| 45 | M&L for Submain wiring with single core 1100 volts 2.5 sqmm two runs FRLSH size PVC insulated PVC unsheathed stranded copper conductor using color code drawn through and including stove steel enameled conduit 20 mm dia with accessories like flame proof bend, flame proof juntion box etc and including 2.5 sqmm PVC insulated PVC unsheathed FRLSH copper conductor in cable for continuous earth continuty conductor by using green colour to common earth and connecting to earth point and connecting to earth dolly complete all as specified and as directed. |
| 46 | M&L for Submain wiring with single core 1100 volts 4 sqmm two runs FRLSH size PVC insulated PVC unsheathed stranded copper conductor using color code drawn through and including stove steel enameled conduit 20/25 mm dia with accessories like flame proof bend, flame proof juntion box etc and including 4sqmm PVC insulated PVC unsheathed FRLSH copper conductor in cable for continuous earth continuty conductor by using green colour to common earth and connecting to earth point and connecting to earth dolly complete all as specified and as directed. |
| 47 | M&L for Submain wiring with single core 1100 volts 6 sqmmtwo runs FRLSH size PVC insulated PVC unsheathed stranded copper conductor using color code drawn through and includingstove steel enameled conduit 25 mm dia with accessories like flame proof bend, flame proof juntion box etc and including 6sqmm PVC insulated PVC unsheathed FRLSH copper conductor in cable for continuous earth continuty conductor by using green colour to common earth and connecting to earth point and connecting to earth dolly complete all as specified and as directed. |
| 48 | M&L for Submain wiring with four core 1100 volts 10 sqmm Four runs FRLSH size PVC insulated PVC unsheathed stranded copper conductor using color code drawn through and including stove steel enameled conduit 32 mm dia with accessories like flame proof bend, flame proof juntion box etc and including 10sqmm PVC insulated PVC unsheathed FRLSH copper conductor in cable for continuous earth continuty conductor by using green colour to common earth and connecting to earth point and connecting to earth dolly complete all as specified and as directed. |
| 49 | S&F in repairs flame proof LED wall glass hanging type 60w fitting on existing light point with suitable hanging arrangements one light control with one MCB SP complete all as specified and directed. Note:The rates includes taking down old light fitting and providing suitable necessary ladders /equipments for any height for taking down the items. |
| 50 | S&F in repairs FLP plugin switch socket, 16A, 3pin (2P+E), 220V, 50 Hz, AC and fixing arrangement complete all as specified and as directed. |
| 51 | S&F in repairs FLP plugin switch socket, 25A, 3pin (2P+E), 220V, 50 Hz, AC and fixing arrangement complete all as specified and as directed. |
| 52 | S&F in repairs FLP plugin switch socket 32A, 5pin (4P+E), 50 Hz, AC and fixing arrangement complete all as specified and as directed. |
| 53 | S&F in repairs FLP LED Typetube light fitting 2 x 20 watt, four feet, 220V, 50 Hz, AC and fixing arrangement complete all as specified and as directed. |
| 54 | S&F in repairs FLP TPN DB, 4 way, 220V, 50 Hz, AC and fixing arrangement incomer MCB 4P 63amp/100 Amp and outgoing MCB sp 12 NOsbus bar 200 Amp complete all as specified and as directed. |
| 55 | S&F in repairs FLP SPN DB, 4 way, 220V, 50 Hz, AC and fixing arrangement incomer MCB 4P 63amp/100 Amp and outgoing MCB sp 12 NOsbus bar 200 Amp complete all as specified and as directed. |
| 56 | S&F in repairs MCCB, 4 pole, thermal magnetic release range 100 Amps, breaking capacity 16 kA, 415 Volts, 50 Hz complete all as specified and as directed. |
| 57 | S&F in repairs MCCB, 4 pole, thermal magnetic release range 40 Amps, breaking capacity 16 kA, 415 Volts, 50 Hz complete all as specified and as directed. |
| 58 | S&F in repairs 6 to 32 Amp, MCB, single pole, 240 V, 10 KA (C-Series) complete all as specified and as directed. |
| 59 | S&F in repairs 32 Amp, MCB, SPN, 240 V, 10 KA (C-Series) complete all as specified and as directed. |
| 60 | M&L for PCC (1:2:4) type B0 (using 12.5mm graded stone aggregates) as in blocks; size as per IE rules including necessary use and waste of form work for grouting of porcelain insulator, complete all as specified and as directed. |
| 61 | M&L for PCC (1:2:4) type B1, (using 20mm graded stone aggregates) for earth chambers as in repairs, coping for GI pipe post including necessary form work, excavation in soft loose soil, returning in filling and removing surplus soil to a distance n. exc 50 mtr and deposing where directed. |
| 62 | S&F in repairs 40 mm dia GI pipe medium grade for post not exceeding 3 mtrs in length truly vertical position embbed in PCC including earth work complete all as specified and as directed. Note : PCC of of pole embeded will be measured and paid separately. |
| 63 | M&L for earthing with GI earth plate electrode of size 60 cm x 60 cm x 6 mm thick burried directly in ground (earth pit not less than 2.25 m deep below ground level) with top edge of the plate not less than 1.5 m below the normal ground level connected with GI strip 32 x 6 mm by means of bolts, nuts, check nuts & washers of galvanished iron steel including necessary excavation and earth work in any type of soil, removing surplus soil to a distance not exc 50 m, with and including PCC chamber in PCC (1:2:4), type B1 (using 20mm graded stone aggregates), angle iron frame made out of MS angle iron of size 40x40x6 mm thick duly painted with two coats of synthetic enamel paint over one coat of red oxide zinc chrome primer hinged with and including 6mm thick CI cover with handle, watering arrangement with funnel internally secured with wire mesh with 20 mm dia medium grade pipe for watering, 40 mm dia light grade GI pipe for lead protection in & including alternate layers of charcoal dust and common salt complete all as shown in electrical plate No 3 of SSR Part-1(2009) connected & including earthing test point including testing on completion complete all as specified and as directed. |
| 64 | S&F in repairs FLP FLEXIBLE metalic pipefor 19/20 mm dia complete all as specified and as directed. |
| 65 | S&F in repairs cable of 10 x 2 sqmm complete all as specified and as directed. |
| 66 | S&F in repairs FLP FLEXIBLE metalic hose conduit 1000 mm long for 19/20 mm dia fixed on directed place complete all as specified and directed. |
| 67 | S&F in repairs FLP rotary switch, single pole, 16 Amps and fixing arrangement complete all as specified and as directed. |
| 68 | S&F in repairs LED building security light, 45 watt with hanging arrangement in wall/surface/ceiling connecting with all required accessories like PVC box base, flexible cable from ceiling rose etc complete all as specified and as directed. |
| 69 | S&F MS sheet of thickness 3mm for mounting FLP switch, socket , DB, cover etc including machining, welding, painting, etc complete all as specified and as directed. |
| 70 | S&F in repairs vitreous china porcelain insulator with busbar support white type,complete all as specified and as directed. |
| 71 | S&F aluminium strip of size 25 mm x 3.15 mm fixed to procelain insulator fixed with suitable saddles & fixing screws etc for roof with rubber & bitumen washer & fixed to insulator only on wall for down conductor, complete all as specified and as directed. |
| 72 | S&F test point terminal block made of gun metal or phosphorus bronze size 75 x 75 x 25 mm thick drilled and screwed including 3 Nos 8 mm dia 25 mm long hexagonal head screws fixed to GI strip bracket fixed to porcelain insulator in wall as in repairs complete all as specified and directed.Note :- Porcelain insulator will be measured & paid for separetly. |
| 73 | S&F in repairs air termination single pointed aluminium rod 12 mm dia and 300mm long with necessary fixing arrangement on blocks on roof, complete all as specified and as directed. |
| 74 | S&F GI strip strip of size 25 mm x 3.15 mm fixed to procelain insulator fixed with suitable saddles & fixing screws etc for roof with rubber & bitumen washer & fixed to insulator only on wall for down conductor, complete all as specified and as directed. |
| 75 | S&F copper strip strip of size 20 mm x 3.15 mm fixed to procelain insulator fixed with suitable saddles & fixing screws etc for roof with rubber & bitumen washer & fixed to insulator only on wall for down conductor, complete all as specified and as directed. |
| 76 | Taking down carefully copper/aluminum point wiring (light, fan, socket or power) complete with wiring acessories such as bends, boards, elbows, ceiling fittings etc and removing material to store for safe coustody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc. complete all as specified and as directed. |
| 77 | Taking out old DB, 8 way any type & make complete all as specified and as directed. |
| 78 | Taking out old cable 10sqmm 2 core any type & make complete all as specified and as directed. |
| 79 | Taking out earthing any type complete all as specified and as directed. |
| 80 | Taking out bldg security light any type & make complete all as specified and as directed. |
| 81 | Taking out old panel any type & make complete all as specified and as directed. |
| 82 | Supplying, jointing, connecting & testing XLPE/PVC insulated PVC sheathed cable, armoured, heavy duty 1100 volts grade, 25 Sqmm, 4 Core, aluminum conductor as in trenches/ducts complete all as specified and as directed. |
| 83 | M&L for dry river sand as sand cushioning for protection of UG cable including punning of sand in layers complete all as specified and as directed. NOTE: Punned thickness shall be measured for payment purpose. |
| 84 | Supplying & laying un-reinforced precast concrete cable cover, class LV, type 1, flat, size 250mm x 150mmx 40mm complete all as specified and as directed. |
| 85 | M&L for 50 mm bore of pipe GI pipe, light grade with all fittings laid in trenches complete all as specified and as directed. |
| 86 | Supplying, installing, testing and commissioning cubical type LT Panel, floor mounted, out door type, 415V, 3 phase, 4 wire system, 50 Hz, AC supply, factory made fabricated from MS sheet totally enclosed, dust weather proof and vermin proof for outer shellhaving TPN aluminium bus bar rating 1.5 times that of controllingMCCB supported onbottom base channel MS section not less than 100mm x 50mm x 5 mm thick, entire panel shall have a common aluminium earth bar of size 25mm x 5mm at the rear with 2 Nos earth stud, solid connection from main bus bar to switchgears with required size of copper wiring with minimum 2.5 Sqmm PVC insulated copper conductor cable, cable alleys, cable gland plates in two half and general construction confirming to IS-8623/93 and wall/floor mounted on suitable PCC foundation with following detailed specifications & controls with suitable fixing accessories complete all as specified and as directed:- OUTER SHELL :- The outer shell shall be made of 3.15 mm thick CRCA body & MS angle section 50x50x6 mm frame with front & back openable, single door system lockable/ openable by keys from both sides having flush pattern fancy locks with louvers & air vent gasket for natural flow of air. The bottom of the outer shell contains a detachable plate ahing provision for entry of armoured cable of adequite size of glands. The dimension of the outer shell shall be adequite to accommdodate inner shell described below 50 mm space all around and shall be fabricated in such a way that the complete inner shell alongiwth its control gears/MCCB and accessories should be taken outside without disturbing outer shell.The outer shell shall be mounted on a zinc metal coated stand. Provision of threaded earthing studs at bottom and lifting lugs of suitable size at top to lift the feeder pillar box safely shall be made. Computer cut self adhesive vinly danger notice plate having conventional symbol of bone and skull shall be provided. The degree of protection of outer shell shall be IP-65. |
| 87 | INNER SHELL :-Inner shel made of 2.0 mm thick CRCA body compartmentalized for each control gear, front openable single door system lockable/openable by keys from both sides having chromium plated fancy locks (2 Nos in each compartment) having louvers and air vents gasket for natural flow of air \"U\" type gasket shall be used to make the inner shell completely vermin proof and to accomodate incomer/outgoing MCCB\"s and TPN aluminium bus bar and extension links of rating not less than the 1.5 times rated capacity of the respective MCCB\"s. The TPN bus bar and exension links shall be insulated with colour coaded heat, shrikable sleeve and shall be mmounted on suitable size \"F\" class through out the length of the TPN bus bar. Computer cut self adhesive vinyl danger notice plate having conventional symbol of bone and skull shall be provoid on bus bar chamber. All control wires shall be with not less than 2.5 Sqmm multistranded copper conductor and shall be properly bunched. tied, ferruled for proper identification and crimped with adequite size of lugs.The cubical shall have a bottom channel of size 75x50mm duly coated with zinc metal coating.A detachable predrilled gland plate of thickness 3.15 mm zinc metal coated should be used at the bottom, indicating lamps LED type, 230 Volt, AC at the incomer of the unit to show three phase availablity at the incomer. The degree of protection for inner shell shall be IP-42 and carry the following control :- (A) INCOMING - MCCB of 200 A, microprocessor based, 4 pole, 415 volt, 50 kA breaking cap. With adjustable over load,short circuit, ground fault (4 pole) & fixed instantanous neutral protection (4 pole), conforming to IS/IEC-60947-2 including spreader terminal kit – 01 No.(B) OUTGOING- (a)MCCB of 100 A, microprocessor based, 4 pole, 415 volt, 35 kA breaking cap. With adjustable over load, short circuit ,ground fault& fixed instantanous neutral protection, conforming to IS/IEC-60947-2 including spreader terminal kit -02 Nos (2 W + 1 spare)(b)MCCB of 63 A, microprocessor based, 4 pole, 415 volt 35 kA breaking cap. With adjustable over load, short circuit ,ground fault& fixed instantanous neutral protection, conforming to IS/IEC-60947-2 including spreader terminal kit - 02 Nos (2 W + 1 spare) (c)MCCB of 40 A, microprocessor based, 4 pole, 415 volt, 35 kA breaking cap. With adjustable over load, short circuit ,ground fault & fixed instantanous neutral protection, conforming to IS/IEC-60947-2 including spreader terminal kit -02 Nos (2 W + 1 spare)(d) Digital type Voltmeter three phase class 0.5, 96 x 96 mm flush mounted case with adeqaute CT arrangemnt (e) Digital type Ammeterthree phase class 0.5,96 x 96 mm flush mounted case with adeqaute CT arrangemnt (f) LED INDICATORS RIBBED LENS WITH TRIMMED COLLAR - Red, Yellow and Blue - 1 Each,(g) Aluminium bus bar of Rating 300 Amp R-Y-B phases andNeutral.(h) Base frame for cubical mounting made out of suitable size equal angle iron duly painted.(j) Foundation for the panel should provided with PCC 1:3:6 type C1 (using 20mm graded stone aggregates) at a depth of 150 mm below G.L. and 100 mm above the G.L. with slot openings for I/C and O/G cables. |