| 1 | Providing and laying two courses water proofing treatment with bitumen felt over roofs consisting of first courses of blown bitumen 85/25 or 90/15 conforming to IS : 702 applied hot @ 1.45 Kg per square metre of area for each course, second course of roofing felt type 3 grade-I (hessian based self finished bitumen felt)including preparation of surface but excluding grading complete with : Bitumen felt (hessian base) type 3 grade I conforming to IS : 1322 |
| 2 | Providing and Laying flash strip wherever required over roof including providing necessary safety measures for the labourers to work at higher elevation, ropes etc., insurance coverage for labourers and hiring of requiring T&P etc complete. |
| 3 | Providing and fixing radial exhaust turbo ventilator (extraction capacity of minimum 100 cft per minute air circulated fan of 22\" throat dia wind ventilator with FRP base plate) including cost of fixing turbo/ wind ventilators on new 0.510mm thick pre-coated GI profile sheet roofing on godown roof including cost of transportation of all materials, tools and plants, fixtures/fastenings, labour insurance safet measures etc., and as directed by the Engineer-in-charge inlcuding guarantee for turbo ventilator of minimum 3 years and performance warranty etc., complete. |
| 4 | Trimming of trees including cutting of trunks and branches, removing the roots and stacking of serviceable material and disposal of unserviceable material. |
| 5 | Servicing and repairing of rolling shutters including removing and refixing of top cover adjusting dislocated laths and leveling the shafts if any cleaning the springs side guide with kerosene oil lightening/loosening the spring applying grease (luberox cup grease II or equivalent) on spring side guiders and making the shutter for easy pull and push operations etc., complete. |
| 6 | Providing and applying tar plastic including cleaning the existing surface free of dust and other foreign matters alround the J bolts points over the AC/GI Sheet roofing for complete water proofing as directed by Engineer-in-charge. |
| 7 | Providing and fixing rolling shutter springs of 27.5 cm long wire spring grade no.2 for rolling shutters including labour charges etc. complete as directed by Engineer-in-charge. |
| 8 | Suppling and fixing at site top cover of rolling shutter 1.20mm thick arrangement complete of required thickness etc., for rolling shutters. |
| 9 | Dismantling roofing including ridges,hips,valleys and gutters etc. and stacking the material within 50m lead of : Asbestos cement sheet. |
| 10 | Dismantling roofing including ridges,hips,valleys and gutters etc. and stacking the material within 50m lead of : GS sheet. |
| 11 | Deduct towards cost of salvage value of dismantled materials received from specified items which shall be issued to contractor and shall be cleared by the contractor from site of work with all leads and lifts complete as directed by the Engineer-in-charge as is where is basis. (a) Dismantled AC Sheet |
| 12 | Deduct towards cost of salvage value of dismantled materials received from specified items which shall be issued to contractor and shall be cleared by the contractor from site of work with all leads and lifts complete as directed by the Engineer-in-charge as is where is basis (b) Dismantled Rolling shutter spring&cover |
| 13 | Dismantling wooden boardings in lining of walls and partitions ,excluding supporting members but including stacking within 50m lead.Thickness above 10mm and upto 25mm. |
| 14 | Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer in-charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. |
| 15 | Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm (+0.05 %) total coated thickness, Zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws complete : Ridges plain (500 - 600mm) |
| 16 | Brickwork with common burnt clay F.P.S(non-modular) bricks of class designation 5.0 in superstructure above plinth level upto floor V level in all shapes and sizes in : cement mortar 1:6( 1 cement : 6 coarse sand ) |
| 17 | 15mm cement plaster on the rough side of single or half brick wall of mix 1:6 (1 cement: 6 fine sand) |
| 18 | Supplying and fixing rolling shutters of approved make, made of required size M.S. laths,interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters. 80x1.20 mm M.S. laths with 1.20 mm thick top cover |
| 19 | Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - chargeNominal concrete 1:3:6 or richer mix (i/c equivalent design mix) |
| 20 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size) |
| 21 | Providing and laying in position cement concrete of specified grade excluding cost of centering and shuttering- All work upto plinth level 1:2:4 (1 cement:2 coarse sand(zone-III) derived from natural sources : 4 graded stone aggregate 20mm nominal size derived from natural sources. |
| 22 | Supplying and filling in plinth with sand under floors including watering,ramming,consolidated and dressing complete. |
| 23 | Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete 40 mm thick with 20 mm nominal size stone aggregate |
| 24 | Clearing grass and removal of the rubbish up to a distance of 50 m outside the periphery of the area cleared. |
| 25 | Cleaning of drains by removing silt,sand,earth sludgeand dry leaves including cleaning other foreign if any such as organic/in organic materials etc.,for smooth running flow of rain water and disposal of cleaned material as directed by the Engineer-in-charge For drains width upto 0.3m |
| 26 | Repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sq.meters and under, including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete, including disposal of rubbish to the dumping ground, all complete as per direction of Engineer-in-Charge. With cement mortar 1:4 (1 cement : 4 fine sand) |
| 27 | Renewing glass panes, with wooden fillets wherever necessary:Float glass panes of nominal thickness 4 mm (weight not less than 10kg/sqm) |
| 28 | Structural steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. |
| 29 | Providing and fixing mild steel round holding down bolts including nuts and washers platescomplete. |
| 30 | Welding by gas or electric plant including transportation of plant at site etc. complete. |
| 31 | Applying priming coat: With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/steel works. |
| 32 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade : Two or more coats on new work |
| 33 | Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm) |
| 34 | Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/sqm including pointing the joints with white cement and matching pigment etc., complete. |
| 35 | Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. |
| 36 | Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead : Of area 3 sq. metres and below |
| 37 | Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid door/ window/ Clerestory windows & other Frames/ Chowkhat comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modulus of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with M.S hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-In- Charge. (M.S hold fast/lugs or SS dash fasteners shall be paid for separately). Note: For WPC solid door/window frames, minus 5 mm tolerance in dimensions i.e depth and width of profile shall be acceptable. Variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be made. Frame size 45 x 70 mm |
| 38 | Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid plain flush door shutter of required size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer-In- Charge. (Note: stainless steel butt hinges and necessary S.S screws shall be paid separately) 30 mm thick |
| 39 | Dismantling of flushing cistern of all types of all types (C.I./PVC/Vitrious China) including stacking of useful materials near the site and disposal of unserviceable materials within 50 metres lead. |
| 40 | Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x410x265 mm sizes respectively. |
| 41 | Providing and fixing PTMT urinalcock of approved quality and colour. 15mm nominal bore, 80 mm long , 42 mm high and 30 mm wide with BSP female threads weighing not less than 48 gms. |
| 42 | Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests |
| 43 | Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required : W.C. pan with ISI marked white solid plastic seat and lid |
| 44 | Providing and fixing wash basin with C.I. brackets, 15 mm PTMT pillar cock, 32 mm PTMT waste coupling of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever required. White Vitreous China Flat back wash basin size 550x400 mm with single 15 mm PTMT pillar cock. |
| 45 | Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. Flexible pipe 32 mm dia |
| 46 | Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. |
| 47 | Providing and fixing PTMT bib cock of approved quality and colour.15mm nominal bore, 86 mm long, weighing not less than 88 gms |
| 48 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall. 20 mm nominaldia Pipes. |
| 49 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings. This includes jointing of pipes & fittings with one step CPVC solvent cement,Trenching,refilling and testing of joints complete as per direction of Engineer in Charge. External work - 25 mm nominaldia Pipes. |
| 50 | Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931 : 15 mm nominal bore |
| 51 | Providing and fixing brass stop cock of approved quality : 20 mm nominal bore |
| 52 | Providing and fixing aluminium work for doors, windows, ventilatorsand partitions with extruded built up standard tubular sections/appropriate Z sections andothersections of approved make conforming to IS: 733 and IS: 1285, fixing withdashfasteners ofrequired dia and size, including necessary filling up the gaps at junctions, i.e.at top, bottom and sides with required EPDM rubber/neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required includingcleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) :Powder coated aluminium (minimum thickness of powder coating 50 micron) |
| 53 | For shutters of doors, windows & ventilators includingproviding and fixing hinges/ pivots and making provisionfor fixing of fittings wherever required including the costof EPDM rubber / neoprene gasket required (Fittingsshall be paid for separately . Powder coated aluminium (minimum thickness of powder coating 50 micron) |
| 54 | Providing and fixing 12 mm thick prelaminated particle board flatpressed three layer or graded wood particle board conforming to IS: 12823 Grade l Type ll, in panelling fixedaluminum doors, windowsshutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of engineer in-charge. Pre-laminated particle board with decorative lamination on both sides. |
| 55 | Providing and fixing glazing in aluminium door, window, ventilatorshutters and partitions etc. with EPDM rubber / neoprene gasketetc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 4.0 mm thickness (weight not less than 10kg/sqm) |
| 56 | Providing and fixing MS grills in required pattern in frames of windows etc. with MS flats,round or square bars etc., including priming coat with approved steel primerallcomplete . Fixed to openings/wooden frames with rawl plugs screws etc. |
| 57 | Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately). Second class teak wood |
| 58 | Providing and fixing panelled or panelled and glazed shutters for doors, windows and clerestory windows, fixing with butt hinges of required size with necessary screws, excluding panelling which will be paid for separately, all complete as per direction of Engineer-in-charge. (Note:- Butt hinges and necessary screws shall be paid separately Second class teak wood 30 mm thick shutters |
| 59 | Providing and fixing fly proof galvanised MSwire gauge towindows and clerestory windows using wire gauge with average width of aperture 1.4mm in both directions with wire of dia 0.63mm all complete. |
| 60 | Providing and fixing glass panes with putty and glazing clips in steel doors,windows,clerestory windows all complete with : 4.0mm thick glass panes |
| 61 | Providing and fixing angle iron frames for doors,windows, ventilators of mild steel angle section of size 35x35x5mm joints mitred and welded by angle iron iron 35x35x5mm or 35x5mm flat pieces to the existing T iron frame or to the wall with dash fastener including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer allcomplete as per direction of Engineer-in-Charge |
| 62 | Providing and fixing aluminium hanging floor door stopper, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete. Twin rubber stopper |
| 63 | Applying priming coat: With ready mixed aluminium primer of approved brand and manufacture on resinous wood and plywood |
| 64 | Providing and fixing G.I.barbed wire fencing of 0.60M height including fixing with M.S Angle iron post over compound wall in CC1:2:4 block and binding the barbed wire with the post by G.I binding wire in five horizontal and two diagnal rows, excluding the cost of CC block and fencing post. |
| 65 | Disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved. |
| 66 | Supply of services of semi-skilled labour like carpenter, Mason, plumber etc. on daily rate basis for day-to-day maintenance atleast weekly once as per direction of Engineer-in-charge. |
| 67 | Supply of services of labour like beldar, coolie, helper etc. on daily rate basis for day-to-day maintenance atleast weekly once as per direction of Engineer-in-charge. |
| 68 | Providing and laying APP (Atactic Polypropylene Polymer) modified prefabricated five layer 3 mm thick water proofing membrane, black finishedreinforced with black fibre matt consisting of a coat of bitumen primer for bitumen membrane @ 0.40 litre/sqm by the same membrane manufacture of density at 25°C, 0.87-0.89 kg/ litre and viscocity 70-160 cps. Over the primer coat the layer of membrane shall be laid using Butane Torch and sealing all joints etc, and preparing the surface complete. The vital physicaland chemical parameters of the membrane shall be as under : Joint strength inlongitudinal and transverse direction at 23°C as 350/ 300N/ 5cm. Tear strengthin longitudinal and transverse direction as 60/80N. Softening point ofmembrane not less than 150°C. Cold flexibility shall be upto -2°C when tested inaccordance with ASTM, D - 5147. The laying of membrane shall be got donethrough the authorised applicator of the manufacturer of membrane : 3 mm thick. |
| 69 | Providing & fixing UV stabilised fiberglass reinforced plastic sheet roofing up toany pitch including fixing with polymer coated \"J\" or \"L\" hooks, bolts & nuts 8mmdia. G.I. plain/ bitumen washers complete but excluding the cost of purlins,rafters, trusses etc. The sheets shall be manufactured out of 2400 TEX panelrovigs incorporating minimum 0.3% Ultra-violet stabiliser in resin system underapproximately 2400 psi and hot cured. They shall be of uniform pigmentationand thickness without air pockets and shall conform to IS 10192 and IS 12866.The sheets shall be opaque or translucent, clear or pigmented, textured orsmooth as specified. 2mm thick flat. |
| 70 | Diluting and injecting chemical emulsion for POST-CONSTRUCTIONAL antitermite treatment (excluding the cost of chemical emulsion) : Treatmentatpoints of contact of wood work by chemical emulsion Chlorpyriphos/ Lindane(in oil or kerosene based solution) @ 0.5 litres per hole by drilling 6 mm diaholes at downward angle of 45 degree at 150 mm centre to centre and sealingthe same. |
| 71 | Diluting and injecting chemical emulsion for POST-CONSTRUCTIONAL antitermite treatment (excluding the cost of chemical emulsion) : Along the external wall where apron is not provided using chemical emulsion@ 7.5 litres/sqm of the vertical surface of the sub structure to a depth of 300mm including excavation channel along the wall and rodding etc.,complete with Chlorpyriphos/ Lindane EC 20% with 1% concentration. |
| 72 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade : one or more coats on old work |
| 73 | Cleaning of rainwater harvesting pit, including lifting / repositioning the Concrete slab, removing silt,earth etc.,taking out the blue metals and making dust free around rain pipe layer by layer and refilling the metals in position around rain pipe for proper fuctioning of collection of rain water and recharge as directed by the Engineer in charge |
| 74 | Chipping of unsound/weak concrete material from slabs, beams, columns etc. with manual Chisel and/ or by standard power driven percussion type or of approved make including tapering of all edges, making square shoulders of cavities including cleaning the exposed concrete surface and reinforcement with wire brushes etc. and disposal of debris for all lead and lifts all complete as per direction of Engineer-In-Charge. 25 mm average thickness |
| 75 | Providing and laying pressed clay tiles (as per approved pattern 20 mm nominal thickness of approved size) on roofs jointed with cement mortar 1:4 (1 cement : 4 coarse sand) mixed with 2% integral water proofing compound, laid over a bed of 20 mm thick cement mortar 1:4 (1 cement : 4 coarse sand) and finished neat complete. |