Sales : +91-777 804 8217
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 16-02-2026 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 23-02-2026 |
| 2 | 13-02-2026 | Amendment No.1 | Financial Bid | 16-02-2026 |
| Sl. No. | Item Description |
| 1 | Civil Works |
| 2 | Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS : 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminnium snap beading for glazing /paneling, C.P. brass/ stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge.(Glazing, paneling and dash fasteners to be paid for separately): |
| 3 | For fixed portionPowder coated aluminium (minimum thickness of powder coating 50 micron) |
| 4 | For shutters of doors, windows & ventilators including providing and fixing hinges / pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber/ neoprene gasket required (Fittings shall be paid for separately)Powder coated aluminium (minimum thickness of powder coating 50 micron) |
| 5 | Providing and fixing 12 mm thick prelaminated particle board flat pressed three layer or graded wood particle board conforming to IS : 12823 Grade I Type II, in panelling fixed in aluminum doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of Engineer - in- Charge.Pre- laminated particle board with decorative lamination on both sides |
| 6 | Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of Engineer - in -Charge. ( Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 5.50 mm thickness(weight not less than 12.50 kg/sqm) |
| 7 | Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete:125 mm |
| 8 | Providing and fixing aluminium hanging floor door stopper, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS: 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete.Single rubber stopper |
| 9 | Providing and fixing bright finished 100 mm mortice lock with 6 levers without pair of handles of approved quality for aluminium door, with necessary screws etc complete as per direction of Engineer- in- charge. |
| 10 | Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm), with necessary accessories and screws etc. complete. |
| 11 | Providing and fixing aluminium tower bolts, ISI marked, anodised(anodic coating not less than grade AC 10 as per : 1868), transparent or dyed to required colour or shade, with necessary screws complete:300x10 mm |
| 12 | Solid masonry using pre cast solid blocks (factory made) of size 30x20x15cm or nearest available size confirming to IS 2185 part I of 1979 for super structure up to floor two level with thickness 15cm in : CM 1:6 ( 1 cement : 6 coarse sand) etc complete |
| 13 | Providing and laying Autoclaved Aerated concrete (AAC) blocks masonry 150mm/230mm/300 mm thick with Grade- I AAC blocks in super structure above plinth level up to floor V level with RCC band at sill level and lintel level with approved block laying polymer modified adhesive mortar all complete as per direction of Engineer-in-Charge. (The payment of RCC band and reinforcement shall be made for seperately). |
| 14 | 12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand) |
| 15 | Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface:Water thinnable cement primer |
| 16 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. |
| 17 | Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile including applying additional coats wherever required to achieve even shade and colour.Two coats |
| 18 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade:Two or more coats on new work |
| 19 | Providing and fixing Fiber Glass Reinforced plastic (FRP) Door Frames of cross- section 90 mm x 45 mm having single rebate of 32 mm x 15 mm to receive shutter of 30 mm thickness. The laminated shall be moulded with fire resistant grade unsaturated polyester resin and chopped mat. Door frame laminate shall be 2 mm thick and shall be filled with suitable wooden block in all the three legs. The frame shall be covered with fiber glass from all sides. M.S. stay shall be provided at the bottom to steady the frame. |
| 20 | Providing and fixing to existing door frames.30 mm thick Fiberglass Reinforced Plastic (F.R.P) flush door shutter in different plain and wood finish made with fire retardant grade unsaturated polyester resin, moulded to 3 mm thick FRP laminate all around, with suitable wooden blocks inside at required places for fixing of fittings and polyurethane foam (PUF) / Polystyrene foam to be used all filler material throughout the hollow panel, casted monoolithically with testing parameters of F.R.P. laminate conforming to table - 3 of IS : 14856, complete as per direction of Engineer- in-charge. |
| 21 | Providing and fixing bright finished brass 100 mm mortice latch and lock, ISI marked, with six levers and a pair of anodised (anodic coating not less than grade AC 10 as per IS: 1868) aluminium lever handles of approved quality with necessary screws etc . complete. |
| 22 | Providing and fixing bright finished brass tower bolts (barrel type) with necessary screws etc. complete:250x10 mm |
| 23 | Providing and fixing 12 mm thick frameless toughened glass door shutter of approved brand and manufacture, including providing and fixing top & bottom pivot &double acting hydraulic floor spring type fixing arrangement and making necessary holes etc. for fixing required door fittings, all complete as per direction of Engineer-in-charge ( Door handle, lock and stopper etc to be paid separately) |
| 24 | Providing and fixing 12 mm thick frameless toughened glass partition of approved brand and manufacture, including top & bottom fixing arrangement and making necessary holes etc. for fixing required fittings, all complete as per direction of Engineer-in-charge |
| 25 | Providing and fixing SS H handle having min 45 cm length in toughed glass door including all necessary screws etc. complete. |
| 26 | Providing and fixing of glass door SS Patch Lock with out handle in toughened glass door including all necessary screws etc. complete |
| 27 | Providing and fixing lead-shielded wooden laminated X-ray door of size 1200 × 2100 mm, consisting of 45?50 mm thick solid core flush shutter made from kiln-seasoned BWP grade hardwood, incorporating continuous lead sheet of 1.5 mm Pb equivalence (or as approved by Radiation Safety Officer) sandwiched within the shutter. The shutter shall be finished on both faces with high-pressure decorative laminate of approved shade, provided with hardwood lipping on all edges with concealed lead overlap. The door shall be fixed in factory-fabricated mild steel / GI lead-lined frame of matching lead thickness with necessary lead overlap with wall shielding. The door shall be provided with lead glass vision panel of matching lead equivalence and fitted with stainless steel 304 grade lever handles fixed on approved mortice lock, heavy- duty stainless steel butt hinges, door stopper, EPDM rubber sealing gasket, and all necessary fittings. The work shall include complete installation, alignment, sealing of joints to prevent radiation leakage, fixing of radiation warning signage, complete in all respects as per CPWD DSR, AERB guidelines and directions of Engineer-in- Charge. |
| 28 | Fire Metal door. Material Specifications: Frame : GI 1.60 mm, Shutter : GI 1.20 mm, Shutter Width / Active Shutter Width : 808.00 mm, Frame Profile: 143.00 mm X 57.00 mm, Frame Profile type : Normal, Frame Rebate : Double, Door type : Single leaf door, Infill Material : Honey Comb, . 2nos Ball bearing butt hinge, BB3090F, SS304, of size 100 x 75 x 3mm with screws in SSS , 1no Euro profile half cylinder 3005, 42mm Key x Blank, Silver satin finish , 2no Surface door closer TS73, size EN2/3/4, with standard arm, Silver finish, 2 nos concealed flush bolt, lock with lever handle on side. The door should have a minimum fire rating of 2hrs . Wall Opening Size 900X1500 mm. |
| 29 | Providing and laying glazed Vitrified Floor tiles in different sizes (thickness to be specified by the manufacturer), with water absorption less than 0.08% and conforming to IS : 15622, of approved brand & manufacturer,in all colours and shade, in floors and skirting, riser of steps, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS : 15477, in average 6 mm thickness, including grouting of joints (Payment for grouting of joints to be made separately).Size of Tile 1200x 600 mm |
| 30 | Grouting the joints of flooring tiles having joints of 3 mm width, using epoxy grout mix 0.70 kg of organic coated filler of desired shade (0.10 kg of hardener and 0.20 kg of resin per kg). including filling /grouting and finishing complete as per direction of Engineer-in-charge. Size of Tile 1200x600mm |
| 31 | Providing and fixing tiled false ceiling of approved materials of size 595 x 595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections (galvanized @ 120 grams per sqm, both side inclusive) consisting of main "T" runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200mm center to center and cross \"T\" of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main \"T\" at 600 mm center to center to form a grid of 1200x600 mm and secondary cross "T" of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main "T" runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x 1.6 mm fixed to ceiling with 12.5mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanised butterfly level clips of size 85x 30x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all T-sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer -in-charge.12.5 mm thick square edge PVC Laminated Gypsum Tile size 595x595 mm made of Gypsum plasterboard , manufactured from natural gypsum as per IS 2095 part I and laminated with white 0.16 mm thick fire retardant PVC film on the face side and 12 micron metalized polyster on the back side with all edges sealed with the face side PVC film which goes around and wraps the edges and is bonded to the edges and the back side metalized polyster film so as to make the tile a completely sealed unit. |
| 32 | Providing and fixing false ceiling with e board classic tile or equivalent make of size 610x610x4 mm ceiling of approved quality in aluminium frame work with necessary screws etc complete ( aluminium frame work shall be paid separately) |
| 33 | Reinforced cement concrete work in beams, suspended floors, roofs, having slope up to 15°landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases up to floor five level excluding the cost of centering, shuttering, finishing and reinforcement, with1:1.5:3 (1 cement : 1.5 coarse sand (Zone III)derived from natural sources: 3 graded stone aggregate 20 mm nominal size derived from natural sources). |
| 34 | Centering and shuttering including strutting, etc. and removal of form for:Lintels, beams, plinth beams, girders bressumers and cantilevers |
| 35 | Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete above plinth level.Thermo - Mechanically Treated bars of grade Fe-500D or more |
| 36 | Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. |
| 37 | Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.Hot finished seamless type tubes |
| 38 | Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 25 mm dia 10 Kgf/cm2- External work - Exposed on wall |
| 39 | Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge.Concealed work, including cutting chases and making good the wall etc. 20 mm pipe 10 Kgf/ cm2 |
| 40 | Demolishing R.C.C. work manually / by mechanical means including stacking of steel bars and disposal of unserviceable material with in 50 metres lead as per direction of Engineer -in-Charge. |
| 41 | Providing, supplying, installing, testing and commissioning a sliding folding partition system for separating two rooms, comprising lightweight modular panels made of pre-laminated MDF boards conforming to IS: 14587:1998, finished with decorative laminate Grade-I (exterior grade) on both sides, fixed with approved screws and fittings, and with all exposed edges sealed using 2.0 mm thick PVC edge banding of approved make. The panels shall be supported on an independent floor-mounted MS/GI structural framework, securely anchored to the floor and adequately designed to carry the entire load of the partition system, as no slab or beam support is available. The extruded aluminium overhead track shall be fixed only to this independent framework, with no load transferred to the ceiling or false ceiling. The system shall include rollers, inter-panel hinges, alignment guide channel, locking arrangement, suspension brackets, end stops, and all necessary fixing accessories to ensure smooth and reliable operation. Panel finish shall be laminate / paint / fabric as approved. The work shall be complete in all respects including fixing, alignment, testing, and making good, in accordance with manufacturer’s recommendations and the directions of the Engineer-in-Charge. |
| 42 | Providing, stitching, and fixing stain-retardant and fire-retardant hospital cubicle curtains suitable for X-ray room, ultrasound room, screening area, and general patient privacy partitions, made from approved quality polyester/antimicrobial fabric of minimum 180–200 GSM, washable and colour-fast, with mesh/net panel not less than 300 mm at the top for ventilation and fire safety compliance, and overall finished curtain height not less than 2.10 m, including full-length pleating (minimum 1.5 times fullness), reinforced heading tape, stainless steel or nylon hooks/rollers, and proper hemming at bottom. The work shall include supply of cloth (minimum rate Rs. 300 per metre or above), stitching, finishing, and fixing to existing or new ceiling- mounted aluminium curtain track/rod, complete in all respects as directed by the Engineer-in-Charge.Rate shall be measured and paid per running metre (Rmt) of curtain track/rod length, inclusive of fabric quantity, stitching, accessories, labour, wastage, and all incidental charges, but excluding the cost of curtain track/rod if supplied separately, complete. |
| 43 | Furniture |
| 44 | Providing reception counter of required size (Minimum width 600 mm and seating height of 750 mm and total height of 1050 ) made up of 18 mm thick pre-laminated medium density fibre board exterior grade (Grade-I) IS: 14587:1998 marked with laminated finish on both sides with cable management tray, grommet, required 3 Nos sockets and Ethernet port, three drawer pedestal unit with channels handles, hinges, lock all complete as per approved design of Engineer in charge/Architect. Elevation area to be measured. |
| 45 | L-Type workstation of overall size (1350 * 600) mm + (900 * 450) mm & 750 mm (LX D X H) and pedestal unit made up of 18 mm thick Exterior Grade-I MDF board on all sides conforming to IS:14587 from approved makes such as Century/Greenply/Fineply or equivalent with decorative laminate on both side and all edges to be fixed with 2mm thick pvc edge beading. One three-drawer modular pedestal unit of minimum size 450 mm (W) X 500 mm (D) X 650 mm (H) all with retractable key board tray, drawer channels, hinges, handles, individual locking system, and all necessary fittings and the workstation should have an electrical flip box with 2 nos universal power socket & 1 no data socket etc and cable management tray. All work as per the approved design and instruction of the Engineer-in-Charge/Architect. |
| 46 | Linear workstation of overall sizeminium1100-1200 mm x 600mm x 750 mm (LX D X H) and pedestal unit made up of 18 mm thick Exterior Grade-I MDF board on all sides conforming to IS:14587 from approved makes such as Century/Greenply/Fineply or equivalent with decorative laminate on both side and all edges to be fixed with 2mm thick pvc edge beading. One three-drawer modular pedestal unit of minimum size 450 mm (W) X 500 mm (D) X 650 mm (H) all with retractable key board tray, drawer channels, hinges, handles, individual locking system, and all necessary fittings and the workstation should have an electrical flip box with 2 nos universal power socket & 1 no data socket etc and cable management tray. All work as per the approved design and instruction of the Engineer-in-Charge/Architect. |
| 47 | Linear workstation of overall size1200mm x 600mm x 750 mm (L X D X H) and pedestal unit made up of 18 mm thick Exterior Grade-I MDF board on all sides conforming to IS:14587 from approved makes such as Century/Greenply/Fineply or equivalent with decorative laminate on both side and all edges to be fixed with 2mm thick pvc edge beading. One three-drawer modular pedestal unit of minimum size 450 mm (W) X 500 mm (D) X 650 mm (H) all with retractable key board tray, drawer channels, hinges, handles, individual locking system, and all necessary fittings and the workstation should have an electrical flip box with 2 nos universal power socket & 1 no data socket etc and cable management tray. All work as per the approved design and instruction of the Engineer-in-Charge/Architect. |
| 48 | Linear workstation of overall size1500mm x 600mm x 750 mm (L X D X H) and pedestal unit made up of 18 mm thick Exterior Grade-I MDF board on all sides conforming to IS:14587 from approved makes such as Century/Greenply/Fineply or equivalent with decorative laminate on both side and all edges to be fixed with 2mm thick pvc edge beading. One three-drawer modular pedestal unit of minimum size 450 mm (W) X 500 mm (D) X 650 mm (H) all with retractable key board tray, drawer channels, hinges, handles, individual locking system, and all necessary fittings and the workstation should have an electrical flip box with 2 nos universal power socket & 1 no data socket etc and cable management tray. All work as per the approved design and instruction of the Engineer-in-Charge/Architect. |
| 49 | Lab work bench -The work bench top made up of 18mm thick granite top edge moulded over 18 mm thick marine plywood and GI Powder coated frame work of section size not less than 50x50x1.5mm. The width of the table shall be 750mm and height shall be 850mm. The frame provided with level adjusting screws fixing accessories ,carriage of material all complete as per the approved drawings and direction of Engineer in charge.Note Only length of the table shall be measured for making payment. |
| 50 | Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS 13983 with C.I. brackets and stainless steel plug 40 mm,with swan neckfaucet with pipe in let and drain provision, including painting of fittings and brackets, cutting and making good the walls wherever required:Kitchen sink with drain board510x1040 mm bowl depth 250 mm |
| 51 | Providing and fixing a dining table of overall size 1800 × 800 × 750 mm with an 18 mm thick engineered quartz stone top of approved make, shade and finish, suitable for dining use, having polished or matt polished surface with machine-cut edges and 3–5 mm chamfer or pencil round. The quartz top shall be mounted on a mild steel sub-frame made of 40 × 20 × 2 mm RHS sections, firmly fixed using approved adhesive and concealed fasteners. The dining table shall be supported on mild steel square tube legs of size 50 × 50 mm and minimum 2 mm thickness, properly welded, ground smooth and finished with powder coating of minimum 60–80 microns thickness in approved colour. Adjustable PVC/nylon levellers shall be provided at the bottom of the legs. The dining table shall be complete in all respects including materials, fabrication, powder coating, fixing and installation at site, and shall be measured per number (each), with the rate inclusive of all labour, tools, transportation and incidental charges. |
| 52 | Providing and fixing dining chair with back rest and without arm suitable for use with dining tables, having a mild steel tubular frame fabricated from 25 × 25 × 1.6 mm square hollow sections, properly welded, ground smooth and finished with powder coating of minimum 60?80 microns thickness in approved colour. The seat and backrest shall be of moulded polypropylene (PP) / ergonomically shaped plywood with laminate finish, firmly fixed to the frame using concealed fasteners. The chair shall have a seat height of approximately 450 mm, with non-slip PVC/nylon end caps provided at the bottom of legs to protect flooring. The chair shall be complete in all respects including materials, fabrication, powder coating, fixing and installation at site, and shall be measured per number (each). |
| 53 | Revolving Chair: Medium back ergonomic chair with five nos. star shaped Nylon base. Castor: 50mm diameter nylon twin wheel, gas lift height adjustment, back angle adjustment , Fixed armrest providing natural resting for arms. Seat with PU coated foam backed fabric, back rest with mesh type fabric, upholstery: Heavy duty rubber backed fabric in BLACK |
| 54 | Office Chair: Non-revolving executive chair with fixed armrest providing natural resting for arms. Seat with PU cutted foam backed fabric, back rest with mesh type fabric, Upholstery: Heavy duty rubber backed fabric in BLACK ( Size -55x60 cm) |
| 55 | Supply of phlebotomy chair with optimum design made up of MS Power coated frame and up upholstery type seat,back rest and arm rests.Both side arm rest should be with height and position adjustable system and all as per the instruction of Engineer in charge. |
| 56 | Counter Height Stools :Supply and erection of counter height stools ( bar stools ) of following specifications: Revolving adjustable Chrome plated steel body chairs with resistance to the corrosion. Cushion Seat with Lift mechanism for Adjustment of height. Minimum height 750mm before expansion. Medium Back rest and arm rest. Item shall be of reputed make. |
| 57 | MS Powder-Coated Cushioned Airport Type Three-Seater Waiting Chair: Providing and supplying airport type three-seater waiting chair having main frame made of heavy duty mild steel (MS) tubular/rectangular section with central beam support, finished with epoxy powder coating of approved shade and thickness not less than 60 microns. Each seat shall be ergonomically designed with cushioned seat and back made of high-density PU foam upholstered with superior quality rexine/fabric, fixed securely to the frame. The chair shall be provided with MS armrests between seats, sturdy MS legs fitted with PVC/nylon bushes for floor protection, suitable for heavy- duty use in hospital waiting areas. The overall size shall not be less than 1500 mm length with minimum 450 mm seat depth and 430-450 mm seat height. The item shall include all materials, labour, fittings, transport, handling and placing at site complete as per the direction of the Engineer-in-Charge. |
| 58 | Cabinet/Wardrobe: Providing and fixing Cabinet/Wardrobe unit with 18 mm thick Multi wood board with one side decorative and other side balancing lamination. cupboard shutters edge to be sealed with PVC edge bending tape 2.00 mm thick of approved brand including ISI marked nickel plated bright finishing M.S. piano hinges conforming to IS:3818 marked with fixing chromium plated brass 50 mm cupboard or wardrobe knobs, special quality chromium plated brass cupboard locks with six levers of approved quality including necessary screws etc. complete. Depth of shelves to be 300-600mm and shelves to be fix with proper support and bracket holders. as per layout drawing approved by Engineer in charge. Make laminate: Greenlam/ Merino / Century. Only front elevation will be measured. |
| 59 | Slotted Angle Racks : Supply and errection of Powder coated slotted angle metalic rack having min 8 shelfs made up of min 40 X 40 X 2 mm size rolled steel angle posts shall have 8-mm diameter holes provided at 50-mm centre to centre. Metal shelves shall be made from mild steel sheets not less than 1.0 mm in thickness and with sufficient stiffners. Shelves shall have lipped flanges width of flange being 30 mm and depth of lip 15 mm .Min size of rack 900mm Length X 300mm Depth X 2000mm Height. |
| 60 | Providing, supplying and placing general hospital examination table made of strong MS tubular frame, duly pre-treated and epoxy powder coated, with a three-section top cushioned with high-density foam and covered with washable, anti-bacterial, fire- retardant synthetic upholstery of approved colour. The table shall have an adjustable backrest and leg section operated manually, provision for paper roll holder, and rubber shoes at the bottom to prevent floor damage. Overall size shall be approximately 1800 mm × 600 mm × 750 mm height, suitable for routine medical examination in hospitals and clinics.The item shall also include an additional step-up stool made of stainless steel (SS 304) with non-slip rubber top surface, sturdy welded construction, and anti-skid rubber legs, suitable for patient access to the examination table. The rate shall include all fittings, accessories, handling, placement, and making good, complete in all respects as per directions of the Engineer-in-Charge. |
| 61 | Providing, supplying and placing a USG (Ultrasound) examination bed made of a strong MS tubular frame, duly pre-treated and epoxy powder coated, suitable for routine ultrasound examinations in hospitals. The bed shall have a fixed or adjustable cushioned top with high-density foam covered in washable, anti-bacterial, waterproof upholstery of approved colour. The bed shall be provided with a headrest section adjustable manually, smooth rounded edges, and anti-skid rubber shoes at the bottom to prevent floor damage.The minimum size of the bed shall be 1800 mm (L) × 600 mm (W) × 750 mm (H). The item shall be complete with all fittings, accessories, handling and placement, trasportation all complete as directed by the Engineer-in-Charge. |
| 62 | Providing, supplying, and fixing semi-blackout / light-filtering roller blinds of approved make and shade, suitable for terrace windows exposed to direct sunlight. The blinds shall be made of polyester / PVC coated fabric with 60–80% light filtering capacity, UV resistant and fade-proof, with a thickness of 0.35–0.55 mm and weight of 300–500 GSM. The roller mechanism shall consist of a heavy-duty aluminium roller tube, chain-operated or spring-loaded system, complete with powder-coated brackets, end caps, and an aluminium bottom bar for proper tension. The work shall include dismantling and removal of existing curtains/blinds including all hardware, cleaning and preparing the window surface, and fixing the new blinds in perfect alignment using stainless steel screws and nylon plugs. The blinds shall be installed strictly as per manufacturer’s instructions, ensuring smooth operation and neat finish, with measurement taken per square metre. |
| 63 | Signage |
| 64 | Providing and fixing 3M Fasara frosted etching film of thickness 25 microns self- adhesive of approved colour, shade, and quality with cutting as per approved design and pattern, including cleaning of glass and making surface smooth for fixing of film to the surface, all completed as per the direction of the engineer in charge. |
| 65 | Providing and fixing in position the signage board made out of 3 mm opaque PVC foam board of computerised cut, PVC non reflective self adhesive vinyl painted foam board of required size and colour. |
| 66 | Backlit Acrilic Board with projected letters: Supply, installation, testing and commissioningof weatherproof backlit acrilic board with projected letters made upof 20mm thick acrilic board and having box depth of min 100mm in approved size and design with reqired LED strips for high glow light. The board shall be fabricated and fixed over suitable welded and painted 25X25X3mm MS angle frame in suitable location and in proper line and level with all necessary fastners, supports etc. Electrical works likes electrical wirings, connections, fittings, externaly fixed weather proof 2/3 pin plug points and sockets including boxes etc. to be complete properly. All fabrication and fixing should be done as per approved design and instructions of Engineerin Charge. (Note: Only front elevation will be measured.) |
| 67 | Vinyl Transparent Vision Glass Stickers: Supply and pasting of Vinyl Transparent Vision Glass Stickers in approved size and design in glass partition and door as per the instruction of Engineer in Charge. |
| 68 | Supplying, fabricating and fixing flex board signage of approved design and size, using high-quality flex media with opaque (black) back, suitable for indoor/outdoor application, including digital printing with minimum 8-pass solvent/eco-solvent printing to ensure colour uniformity and clarity, complete as directed by the Engineer- in-Charge. The flex shall be stretched and fixed on a rigid framework fabricated from G.I. square tubes of minimum size 25 mm × 25 mm (1 inch × 1 inch) of suitable thickness, properly welded, cleaned and treated with one coat of red oxide/zinc chromate primer and two coats of approved synthetic enamel paint. The board shall be securely fixed to wall or structure with required clamps, bolts, nuts, screws, anchors, drilling and finishing, complete in all respects. Measurement shall be in square metre of exposed flex area. |
| 69 | Providing and fixing non-illuminated foam board signage of approved design, size and colour, made from high-density PVC foam board (Sunboard or equivalent) of minimum 5 mm thickness, suitable for indoor application, finished with high-quality digital printed vinyl / self-adhesive vinyl (minimum 720 dpi, 6–8 pass printing) as per approved artwork, including surface preparation, pasting, trimming and neat edge finishing. The foam board shall be fixed to wall, partition or ceiling using approved adhesive, double-sided tape, screws with caps or spacers, including all necessary fittings, hardware, labour, scaffolding and incidentals, complete as directed by the Engineer-in-Charge. Measurement shall be in square metre of finished exposed area. |
| 70 | Wiring |
| 71 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required. Group C |
| 72 | Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point (without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required. Group C |
| 73 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required: 2x1.5 sq.mm + 1x1.5 sq.mm earth wire |
| 74 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required 2X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire |
| 75 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed vmedium class PVC conduit as required 2 X 4 sq. mm + 1 X 4 sq. mm earth wire |
| 76 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required: 2 X 6 Sq.mm + 1 x 6 sq.mm earth wire |
| 77 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required: 2 X 10 sq. mm + 1 X 6 sq. mm earth wire |
| 78 | Fixtures |
| 79 | Supply and Installation of surface/recess mounted LED 2x2 luminaire with CRCA housing suitable with fully diffused diffuser for general lighting. The luminaire should have CRI > 80 and CCT of both 6500K/5700K, Cool White Light. The luminaire shall be compliant with IP20 and IK02 classification. Luminaire shall be designed to emit at least 3700 nominal lumens and efficacy of atleast 105 lumen/watt and Minimum system wattage of 36 Watts. The luminaire shall be designed so as to ensure lumen depreciation of up to 30% over 50k burning hours. The electronic driver used shall have a power factor 0.95 and THD. Make - Philips, Crompton, Wipro or equivalent |
| 80 | Providing and fixing to existing door frames.30 mm thick Fiberglass Reinforced Plastic (F.R.P) flush door shutter in different plain and wood finish made with fire retardant grade unsaturated polyester resin, moulded to 3 mm thick FRP laminate all around, with suitable wooden blocks inside at required places for fixing of fittings and polyurethane foam (PUF) / Polystyrene foam to be used all filler material throughout the hollow panel, casted monoolithically with testing parameters of F.R.P. laminate conforming to table - 3 of IS : 14856, complete as per direction of Engineer- in-charge. |
| 81 | Supply and Installation of surface mounted LED Tubelight. The luminaire should have CRI > 80 and CCT of both 6500K/5700K. The luminaire shall be compliant with IP20 and IK02 classification. Luminaire shall be designed to emit at least 2100nominal lumens and efficacy of atleast 105 lumen/watt and Minimum system wattage of 20 Watts. The luminaire shall be designed so as to ensure lumen depreciation of up to 30% over 25k burning hours. The electronic driver used shall have a power factor 0.95 and THD. Make-Philips, Crompton, Wipro, Havells |
| 82 | Supplying and fixing suitable size PVC box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required. |
| 83 | Supplying and fixing suitable size PVC box with modular plate and cover in front on surface or in recess in existing flip box including providing and fixing 3nos of 3 pin 5/6 amps modular socket outlet and 1 no 5/6 amps modular switch, one number 1/2 module box with RJ 45 Socket with connection etc as required. |
| 84 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required. (For light plugs to be used in non residential buildings). |
| 85 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required. |
| 86 | Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required. |
| 87 | Supplying and fixing call bell/ buzzer suitable for single phase, 230 volts, complete as required. |
| 88 | Supplying and fixing PVC batten/ angle holder including connection etc. as required. |
| 89 | Supplying, conveyance and Installation of 150-250 mm sweep,1350 rpm, 3 - 5 blade BLDC Exhaust Fan including frames and all mounting accessories complete.Recommended Make: Atomberg Efficio/Crompton Brisk Air |
| 90 | Supplying, conveyance and Installation of BLDC Type Wall Fan having 3 blade, 400mm sweep, Speed 1350 rpm, Air Delivery 70 CMM minimum, Wall Mount Fan including frames and all mounting accessories complete. Recommended Make: Atomberg Renesa/V-Guard ENVIRO WF BLDC/Havells Platina |
| 91 | Supply, Installation of 12 Watt LED Bulb. |
| 92 | DB and Switchgear |
| 93 | Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, \"\"C\"\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole |
| 94 | Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, \"\"C\"\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole and netural |
| 95 | Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, \"\"C\"\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Triple pole |
| 96 | Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required. |
| 97 | Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps |
| 98 | Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.63 amps |
| 99 | Supplying and fixing following rating, double pole, (single phase and neutral), 240 Volts, residual current circuit breaker (RCCB), having a sensitivity current 30 milli amperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.25 amps |
| 100 | Supplying and fixing following rating, double pole, (single phase and neutral), 240 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 milli amperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps |
| 101 | Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 milli Amperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps |
| 102 | Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 milli Amperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.63 amps |
| 103 | Supplying and fixing DP sheet steel enclosure on surface/ recess along with 25/32amps 240 volts "C" curve DP MCB complete with connections, testing and commissioning etc. as required. |
| 104 | Supplying and fixing TP sheet steel enclosure on surface/ recess along with 16/25/32amps 415 volts "C" curve TP MCB complete with connections, testing and commissioning etc. as required. |
| 105 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)12 way, Double door |
| 106 | Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 volts, on surface / recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 4 Way (4+12)Double door) |
| 107 | Supplying and fixing TP sheet steel enclosure on surface/ recess along with 40 amps 415 volts "C" curve TP MCB complete with connections, testing and commissioning etc. as required. |
| 108 | Supplying and fixing TP sheet steel enclosure on surface/ recess along with 100A 30 mA, 415 volts "C" curve FP ELCB complete with connections, testing and commissioning etc. as required. |
| 109 | Network and Telephone System |
| 110 | Supplying and drawing following pair 0.5 mm dia FRLS PVC insulated annealed copper conductor,unarmored telephone cable in the existing surface/ recessed steel/ PVC conduit as required.4 Pair |
| 111 | Supplying and drawn of UTP 4 pair CAT 6 LAN cable in the existing surface/recessed steel/PVC conduit as required. 1 run of Cable |
| 112 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm |
| 113 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm |
| 114 | Supply and fixing of 6U wall mounting rack with supply and fixing of mounting brackets for support Lockable Front Door and Detachable Side Doors, Cable Manager and PDU of 4 or 6 sockets including cooling fan with accessories complete |
| 115 | Supply, installation, testing, and commissioning of an enterprise-grade managed network PoE switch suitable for LAN access applications. The switch shall be provided with a minimum of 24 ports 10/100/1000 Mbps Ethernet ports and minimum 2 numbers SFP/SFP+ uplink ports, supporting non-blocking architecture with adequate switching capacity for full-duplex operation. The equipment shall support Layer-2 switching features including IEEE 802.1Q VLAN, STP/RSTP/MSTP, Link Aggregation (LACP), IGMP snooping, and Quality of Service (QoS) with traffic prioritization based on 802.1p/DSCP. The switch shall provide enterprise-grade security features such as port security, access control lists (ACLs), secure management through SSH/HTTPS/SNMPv3, and centralized authentication using RADIUS/TACACS+. Management shall be possible through web-based GUI, CLI, and SNMP, with support for logging, monitoring, and firmware upgrades. The switch shall comply with applicable IEEE standards, be rackmountable with all accessories, operate on 230 V AC, 50 Hz power supply. Make: Cisco Catalyst / Fortinet / CommScope |
| 116 | Supply, installation, testing, and commissioning of 24-Port, 1U, Cat6A fully loaded shielded patch panel, suitable for high-speed structured cabling systems in data and networks. Make - Molex / Legrand / D-Link/ equivalent |
| 117 | Supply, installation, testing, and commissioning of 16-Port IP-PBX system supporting minimum 16 extensions, compatible with SIP protocol and suitable for IP and/or analog telephones. The system shall support Caller ID, call transfer, call forwarding, call hold, conference calling, voicemail/IVR, CDR, and music on hold. The IP-PBX shall support SIP trunks/PSTN lines, standard voice codecs, web-based configuration, and shall be supplied complete with IP-PBX unit, power supply, licenses (if any), and all accessories required for integration and operation. The work shall include complete configuration, testing, commissioning. Make: Grandstream / Matrix / NEC / Yeastar / Syntel |
| 118 | Supply and fixing of 4U wall mounting rack with supply and fixing of mounting brackets for support Lockable Front Door and Detachable Side Doors, Cable Manager and PDU of 4 or 6 sockets including cooling fan with accessories complete. |
| 119 | Supply and Fixing suitable size modular GI box with cover in front on and providing and fixing 1 no RJ 45 including connections as required. |
| 120 | Supplying and fixing following modular switch/ socket on the existing modular plate & amp; switch box including connections but excluding modular plate etc. as required.Telephone socket outlet |
| 121 | CCTV System |
| 122 | Supply, Conveyance and Installing of 4/5MP IP Dome/Bullet Camera having 1/3" Progressive Scan True Day and Night Colour IR Camera having effective pixel of 4/5 MP, Video frame rate of 4/5MP @30FPS, Minimum illumination of 0.01 [email protected], 0 lux@IR On, 30-50 M IR Range, 24 IR LED, AWB, AGC, BLC, 2D Noise reduction, with 3.6mm board lense, 12 VDC, PoE IP67 rated weatherproof performance. 1 year warranty. Make: Bosch/CP Plus/Honeywell/Hikvision or equivalent |
| 123 | Supply and fixing of 4U wall mounting rack with supply and fixing of mounting brackets for support Lockable Front Door and Detachable Side Doors, Cable Manager and PDU of 4 or 6 sockets including cooling fan with accessories complete. |
| 124 | Supply Installation Testing and Commissioning of 32 channel embedded Linux NVR (Network Video Recorder), must connect 32 channel IP cameras, Should support min 2 SATA HDD and each should support Min 2TB and must record video simultaneously, (Recording Type: Continuous, Motion Detection, Alarm, Smart Event, Event Motion Detection, Alarm, Smart Event), Video Compression H.265(HEVC)/H.264+/H.264, 2 Year Warranty, Image quality should be maintained throughout the warranty period. Make: CP Plus/Hikivision/Dahua or equivalent |
| 125 | Supply and Installation of Network Switch. 8 Port PoE Switch 1000BASE-T Copper Ethernet PoE+ connections, 10M/100M/1G RJ-45 copper ports, 1000BASE-X Fiber SFP ports, 8 port Auto sensing 10/100/1000 Mbps PoE, minimum CPU memory 512 MB with 2 SFP/combo ports, Energy Efficient Ethernet (IEEE 802.3az). Make: Cisco/CP Plus/ Netgear or equivalent. |
| 126 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm |
| 127 | Supply, laying, testing, and commissioning of CAT 6A U/UTP cable suitable for 10G Ethernet applications, including termination at both ends with suitable connectors as required. |
| 128 | Supply and Installation of 2TB internal hard disk for use in Network Video Recorder (NVR) systems for CCTV/video surveillance. The hard disk shall be of surveillance grade, specifically designed for 24×7 continuous operation and capable of handling multi-camera recording without data loss. The drive shall be of 3.5 SATA form factor with SATA III (6Gb/s) interface and optimized firmware for sequential write operations, vibration tolerance, low power consumption, and error recovery suitable for NVR workloads. The hard disk shall have a workload rating appropriate for continuous surveillance applications and be compatible with the specified NVR model. The supply shall include all necessary mounting accessories, cables, and connectors required for proper installation. |
| 129 | Supply, Installation, testing and commissioning of 43 inch Android 4K LED TV including wall/ table mounting accessories complete. Make: Sony/Samsung/LG |
| 130 | Supply and Installation of LED Color Monitor of full HD minimum 21 inch with mounting accessories complete.Make: LG/Samsung/Panasonic or equivalent |
| 131 | Supply and Installation of Wireless Mouse. Make: HP/Dell or equivalent |
| 132 | Supply of factory-terminated and tested Category 6A Shielded Patch Cord (STP) of 2 meter length, and capable of supporting 10 Gigabit Ethernet (10GBASE-T) applications. |
| 133 | Supply of factory-terminated and tested Category 6A Shielded Patch Cord (STP) of 1 meter length, and capable of supporting 10 Gigabit Ethernet (10GBASE-T) applications. |
| 134 | UPS |
| 135 | Supply, Installation, Testing and Commissioning of True on-line Double Conversion 20 KVA UPS system with 3:3 Crest Factor Three Phase Input Three Phase Output. Inversion shall be Microprocessor controlled with instantaneous sine wave Control using IGBT. UPS shall have standard display features, alarms, safeties, etc Input Voltage range : a) Phase – Three Phase with ground b)Votage range 190 VAC – 470 VAC c)Input Frequency :50/60 Hz d)Power Factor : 0.95 or above e)THD : less than 5% with full load Bypass f) Voltage Range – 200VAC – 240 VAC ) Frequency range – 45-55 Hz/55-65 Hz Output Voltage Range h)Voltage Range – 200VAC – 240 VAC i)Frequency range – 50/60 Hz j)Voltage distortion – linear load <= 2% k)Voltage\ distortion – nonlinear load <= 5% l)Output waveform – pure sinewave m) Crest Factor – 3:1 Minimum Back up time : Continuous 30 Minutes at full load Rectifier shall be Full wave Type (Shall fully meet the specified input power requirements) Battery Type: Sealed Lead Acid Maintenance Free 65AH, Battery Nos and capacity shall be designed for optimum storage space and suitable battery rack, Installation &Commissioning Required Breakers also needs to be provided in input and output side for the UPS. Make: Liebert Vertiv / APC by Schneider / Numeric by Legrand |
| 136 | Cable and end termination |
| 137 | Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 16 sq mm with factory made clamp |
| 138 | Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages, colour washing etc. as required.4 core 25 sq mm with factory made clamp |
| 139 | Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages, colour washing etc. as required.4 core 35 sq mm with factory made clamp |
| 140 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 16 sq. mm (28mm) |
| 141 | Supply and laying of one number additional PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in ground in the same trench in one tier horizontal formation including widening the trench by 20cm, refilling the trench etc. as required but excluding sand cushioning and protective covering (in ordinary soil)3.5 core 50 sq mm |
| 142 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 25 sq. mm (28mm) |
| 143 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2 X 50 sq. mm (35mm) |
| 144 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KVgrade as required.4 X 35 sq. mm (32mm) |
| 145 | Dumbwaiter |
| 146 | Supply, installation, testing, and commissioning of electrically operated laboratory dumbwaiter of minimum 100 kg capacity, suitable for transporting laboratory materials. The car shall be of SS 304 stainless steel construction with internal size 300mm × 300mm × 300mm with 2 stops, smooth hygienic finish, ventilated panels, and non-slip SS floor. The system shall be complete with electric motor, steel wire ropes, machined guide rails, SS 304 landing doors with electromechanical interlocks, automatic/semi-automatic controls, call & send buttons, overload protection, limit switches, emergency stop, and all standard safety devices. The work shall include complete installation, testing, commissioning, statutory compliance from Kerala State Electrical Inspectorate (if applicable), and conforming to relevant IS standards and local lift rules. |
| 147 | Air conditioning system |
| 148 | Supply, installation, testing and commissioning of Split Air Conditioner of following capacity and specifications: Consisting of high wall-mounted type room unit with cordless remote control and one number outdoor condensing unit comprising of energy-efficient suitable rotary compressor for operation on single-phase, 230 V, 50Hz supply, fixing the outdoor unit on a raised platform as per manufacturers recommendation and fixing of room (fan coil) unit on wall, standard 3 m distance refrigerant copper piping with 13mm nitrile rubber insulation, providing and making interconnection between room & condenser as per site conditions, comprising of 1 dia drain PVC pipe with insulation up to 3 m, canvas connections, full electrical cabling from power plug near indoor unit and to outdoor unit, ODU MS stand, first charge refrigerant gas, suitable stabilizer etc complete as required. (Make: Blue Star/LG/ Carrier or equivalent). 2 TR 3 Star rated (inverter type AC) as per BEE |
| 149 | Supply, installation, testing and commissioning of Split Air Conditioner of following capacity and specifications: Consisting of high wall-mounted type room unit (fan coil) with cordless remote control and one number outdoor condensing unit comprising of energy-efficient suitable rotary compressor for operation on singlephase, 230 V, 50Hz supply, fixing the outdoor unit on a raised platform as per manufacturers recommendation and fixing of room (fan coil) unit on wall, standard 4m distance refrigerant copper piping with 13mm nitrile rubber insulation, providing and making interconnection between room & condenser as per site conditions, comprising of 1" dia drain PVC pipe with insulation up to 4 m, canvas connections, full electrical cabling from power plug near indoor unit and to outdoor unit, ODU MS stand, first charge refrigerant gas, suitable stabilizer etc complete as required. (Make: Voltas, Blue Star, Hitachi, Carrier or equivalent). 1.5 TR 3 Star rated (inverter type AC) as per BEE |
| 150 | Supply, installation, testing and commissioning of Split Air Conditioner of following capacity and specifications: Consisting of high wall-mounted type room unit with cordless remote control and one number outdoor condensing unit comprising of energy-efficient suitable rotary compressor for operation on single-phase, 230 V, 50Hz supply, fixing the outdoor unit on a raised platform as per manufacturers recommendation and fixing of room (fan coil) unit on wall, standard 3 m distance refrigerant copper piping with 13mm nitrile rubber insulation, providing and making interconnection between room & condenser as per site conditions, comprising of 1" dia drain PVC pipe with insulation up to 3 m, canvas connections, full electrical cabling from power plug near indoor unit and to outdoor unit, ODU MS stand, first charge refrigerant gas, suitable stabilizer etc complete as required. (Make: Blue Star/LG/ Carrier or equivalent). 1 TR 3 Star rated (inverter type AC) as per BEE |
| 151 | Drain Piping for Split ACs: Supply & installation of PVC insulated piping for condensate drain Including wall chasing, necessary supports, Clamps etc complete as required |
| 152 | Supplying additional copper piping of required size and connecting the same to the available piping and extension of the same through PVC duct inside false ceiling |
| 153 | Diesel Generator |
| 154 | Supply, Installation, Testing and Commissioning of Digital Three Phase Automatic Changeover with Current Limiter (ACCL) TPN_TPN, 63A Mains/63A Genset suitable for 4 pole, 3P + N, 415V, Class 1 Accuracy, with programmable settings for Overvoltage, undervoltage, warning cycles, DG On time, DG output supply, single phasing protection, fault tripping and automatic interchanging/switchover between EB and DG, LED Display with run parameters displayed on screen including suitable enclosure complete. Make: LT/Hager/Havells/ABB/Schneider/Siemens |
| 155 | Supply, Installing, Testing and Commissioning of Silent Type Diesel Generating set having CPCB IV+ acoustic enclosure having Prime Power Rating of 60 KVA, 415 volts at 1500 RPM, 0.8 lagging power factor at 415 V suitable for 50 Hz, 3 phase system & for 0.85 Load Factor and consisting of the followings:Diesel engine radiator cooled, electric start, of suitable BHP at 1500 RPM suitable for above output of alternator capable of taking 10% over loading for one hour after 12 hours of continuous operation. The engine will be fitted complete with all the required accessories. Engine mounted Instrument Panel fitted with and having digital display and necessary indication coupled to Synchronous alternator rated at 60 KVA, 415 volts at 1500 RPM, 3 phase 50 Hz, AC supply with 0.8 lagging power factor. Both the engine and alternator shall be mounted on suitable base frame made of MS channel with necessary reinforcement which shall be installed on suitable cement concrete foundation and vibration isolation arrangement as per recommendations of manufacturer. Daily service fuel tank of minimum 140 litres capacity fabricated out of 3 mm thick M.S. sheet complete with all standard accessories and fuel piping between fuel tank and diesel engine with MS class& lsquo; C’ pipes of suitable dia. Complete with valves, level indications & accessories as required as per specifications. Dry exhaust manifold with hospital exhaust silencer and catalytic convertor. 12V/24V DC starting system comprising of starter motors: voltage regulator and arrangement for initial excitation complete with suitable nos. of batteries (lead acid type) as required as per specifications. Acoustic and weather proof enclosure with arrangement for fresh air intake for cooling of the engine & alternator, extraction, discharging hot air in to the atmosphere as per specifications. |
| 156 | Earthing |
| 157 | Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. |
| 158 | Supplying and laying 25 mm X 5 mm copper strip at 0.50 metre below ground as strip earth electrode, including connection/terminating with nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of brass nut bolt & amp; spring washer spaced at 50mm) |
| 159 | Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required4.00 mm copper conductor (8 SWG) |
| 160 | Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.4.00 mm (8 SWG) |
| 161 | Fire Alarm System |
| 162 | INTELLIGENT FIRE ALARM SYSTEMSupplying, installation, testing & commissioning of addressable fire control module complete as required. |
| 163 | INTELLIGENT FIRE ALARM SYSTEMSupplying, installation, testing & commissioning of addressable manual call point complete as required. |
| 164 | INTELLIGENT FIRE ALARM SYSTEMSupplying, installation, testing & commissioning of addressable horn cum strobe complete as required. |
| 165 | INTELLIGENT FIRE ALARM SYSTEMSupplying, installation, testing & commissioning of intelligent analog addressable photothermal detector complete with mounting base complete as required. |
| 166 | INTELLIGENT FIRE ALARM SYSTEMSupplying, installation, testing & commissioning of response indicator on surface/ recessed MS Box having two LED, metallic cover complete with all connections etc as required. |
| 167 | INTELLIGENT FIRE ALARM SYSTEMSupplying, installation, testing & commissioning of fault isolator complete with base as required. |
| 168 | INTELLIGENT FIRE ALARM SYSTEMSupplying, installation, testing & commissioning of intelligent addressable thermal detector with rate of rise cum fixed tempreature thermistor complete with base as required. |
| 169 | CABLING & WIRINGSupplying &laying of 2x1.5 sq mm fire alarm armoured cable, 600/1000V rated with annealed copper conductor having XLPE insulation, steel wire armouring & FRLS outer sheath complete as required. |
| 170 | Supplying, Installation, testing & commissioning of external power supply unit provides regulated and filtered 24 VDC power for hooter operation.Battery backup with built in charging. |
| 171 | Supply, Installation, Integration and Commissioning of analog addressable Single Loop Fire Alarm Control Panel having capacity upto 4 loop cards, onboard USB Protocol, RS-485 Connectivity, touch pad, each loop shall support minimum 250 devices, connectivity via modbus, ethernet, construction 16 guage CRCA sheet with powder coated finish, IP 50 Indoor, including 1 no analogue addressable loop card complete. Make: Ravel/Agni/ASES or equivalent |
| 172 | Fire extinguisher & signages |
| 173 | Supply & installation of CO2 type fire extinguisher of 4.5 kgs. Make SAFEX / MINIMAX / CEASEFIRE or equivalent |
| 174 | Supply & installation of ISI ABC type fire extinguisher of 4 kgs. Make SAFEX / MINIMAX / CEASEFIRE or equivalent (UL Listed) |
| 175 | Supplying and fixing RJ45 Outlet including cover plate, Keystone Jack and Gang box supporting, connection etc. as required |
| 176 | Supply & Installation of photoluminescent signage in rigid sheet of standard size.(FIRE EXTINUISHER/FIRE DUCT/ NO SMOKING/ FIRE ALARM CALL POINT/EXIT/FIRE EXIST). To be installed on wall or hanging as required. |
| 177 | Supplying & Installing of Clean agent based automatic modular fire extinguisher (ceiling mounted) suitable for A,B,C class fires & electrical fires, Capacity - 5 kgMake : SAFEX/MINIMAX/CEASEFIRE or equivalent |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail