| 1 | Part 1 - LAN and cabling |
| 2 | OD296181/2025-2026:Supply and installation of 48port Access Switch with minimum 48x GE RJ45 and 4x 10GE SFP+ ports. Switching throughput - 176 Gbps, Forwarding Capacity - 262 Mpps, 32K MAC Address, IPv4 and IPv6 static routing. RIPv1/v2, RIPng, OSPFv2/v3 Should support IEEE 802.3ad Link Aggregation with LACP,Link Aggregation Group Size 8, Should support virtual wire between two ports for troubleshooting,should support Static L3 hardware-based routing ,Switch should support IP conflict detection and notification,should support LLDP, should support Storm Control, LoopGuard,LLDP-MED, MCLAG(Multi-chassis link aggregation.Switch should support Device Detection to understand the type of device operating systems, display the IP address.,Should support centralized security management, configuration and reporting through a single console from existing switch controller or from external NMS RIPv1/v2, RIPng, OSPFv2/v3, Certification FCC, CE, RCM, VCCI, BSMI, UL, CB, RoHS2 Preferred Make : Cisco,Juniper,HP,Fortinet |
| 3 | OD296182/2025-2026:Supply and installation of 24 port Access Switch with minimum 24x GE RJ45 and 4x 10GE SFP+ ports. Switching throughput - 128 Gbps, Forwarding Capacity - 190 Mpps, 16K MAC Address, 1GB DDR4,256MB flash,redundant AC power supply,IPv4 and IPv6 static routing RIPv1/v2, RIPng, OSPFv2/v3 Should support IEEE 802.3ad Link Aggregation with LACP,Link Aggregation Group Size 8, Should support virtual wire between two ports for troubleshooting,should support Static L3 hardware-based routing ,Switch should support IP conflict detection and notification,should support LLDP, should support Storm Control,LoopGuard,LLDP-MED, MCLAG(Multi-chassis link aggregation.Switch should support Device Detection to understand the type of device operating systems, display the IP address.,Should support centralized security management, configuration and reporting through a single console from existing switch controller or from external NMS RIPv1/v2, RIPng, OSPFv2/v3, Certification FCC, CE, RCM, VCCI, BSMI, UL, CB, RoHS2. MAF to be attached. Preferred Make : Cisco,Juniper,HP,Fortinet |
| 4 | OD296183/2025-2026:Supply ,laying, testing and commissioning of 1Meter MTP to 4* LC pair SMF Passive breakout cable. Preffered Make: Molex / AMP/ Legrand |
| 5 | OD298948/2025-2026: Supply and installation of QSFP+ 40Gb optics 4x10base - LR 1310nm upto 10KM transmission module. Approved make : Juniper |
| 6 | OD296190/2025-2026:Supply , laying, testing , Certificaton and documentation of 3Meter LSZH RoHs 10G DAC cable compliant fiber patch cord(single Mode).Preffered Make: Molex / AMP/ Legrand |
| 7 | OD296202/2025-2026:Supply and fixing of Dual spring shutter /dust cover face plate + RJ45 and RJ 11 Jack including termination charges etc. on surface/recess using PVC/metal mounting box. Preferred make: Molex/ AMP/Legrand/Actassi/ Belden /R and M/ Systimax |
| 8 | OD296203/2025-2026:Supply and fixing CAT-6 Information Outlet for 1000Mbps with spring shutter /dust cover face plate + Single RJ45 Jack including termination charges etc. on surface/recess using PVC/metal mounting box. Preferred make: Molex/ AMP/Legrand/Actassi/ Belden /R and M/ Sytimax |
| 9 | OD290815/2024-2025:Supply, Installation, Testing and Fixing of UL Listed CAT6 Keystone for existing patch panelApproved Make: Actassi, Belden, Panduit, Molex, R and M, Systimax . |
| 10 | OD290818/2024-2025: Supply and fixing 24 port Enhanced CAT-6, unloaded rack mountable modular type Patch Panel as per EIA/TIA-TSB 40A specification for interconnecting servers and clients, including termination charges.Approved Make: Actassi, Belden, Panduit, Molex, R and M, Systimax . |
| 11 | OD290817/2024-2025:Supply and providing 1 Mtr CAT-6 (LSZH) Giga UTP patch cord.Preferred make: Actassi/ Belden/ Panduit,/ Molex/ R and M/ Systimax. |
| 12 | OD296219/2025-2026:Supply and providing 2 Mtr CAT-6 (LSZH) Giga UTP patch cord.Preferred make: Actassi/ Belden/ Panduit,/ Molex/ R and M/ Systimax. |
| 13 | OD290812/2024-2025:Supply and laying of industrial grade 80SWG PVC insulated GI Taut/Stay wire with supporting poles for laying of cable |
| 14 | OD290819/2024-2025:Supply, laying, testing (OTDR), certification and documentation of Single mode 6 core armored OS2 type outdoor fiber cable ,unitube,single sheathed,corrugated steel tape ,UV stabilised,polyethelene outer anti-termite and anti rodent, water blocking, gelly filled cable through conduit. Prefered Make : AMP/Molex/ Finolex/Delton. |
| 15 | OD290807/2024-2025: Supply and Installation of Fiber SM patch cord with LC-SC connectors and 1 meter length. Approved Make: Belden, corning, Finolex, Molex, R and M, Sterlite, systimax |
| 16 | OD298241/2025-2026: Supply and installation of 10G base single mode Optical Transceiver SFP+ module with minimum reach of 10 KM compatible with switch. |
| 17 | OD295304/2025-2026:Supply and Installation of Fiber SM patch cord with LC-LC connectors and 1M length.Make: Molex |
| 18 | OD295303/2025-2026:Supply, installation , Testing and commissioning of 12 Port fully loaded 1U Rack mountable LIU with Splice tray ,pigtails and cable management. Make: Molex |
| 19 | OD298960/2025-2026:Supply and Installation of 6 Port fully loaded 1U Rack mountable LIU with Splice tray ,pigtails and cable management. Make: Molex |
| 20 | OD290810/2024-2025: Supply, Installation, Testing and Commissioning of 24 Port fully loaded 1U Rack mountable LIU(Swing Type)with Splice tray ,pigtails and cable management. Preferred Make: AFL, Belden, corning, Finolex, Molex, R and M, Sterlite, Systimax |
| 21 | 1.21.1:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm |
| 22 | 1.21.2:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm |
| 23 | 90.9.2.1:Supply and fixing 100 x 50 mm PVC Cable Management System with base and lid along with the following accessories conforming to IEC 61084/ BS 476 & 4678 on surface / recess including cutting the wall and making good the damages in case of recessed installation as required.100 x 50 mm CMS with base and lid |
| 24 | OD296220/2025-2026:Supply and fixing of 19 inch 9U Network Rack with front lockable glass door, rear openable steel door, side integrated/welded panel, castors, 600W X 800D Includes Fan Module/2Fan/Tower mount/trays Power ist. Unit/Horz/6soc/6A/indian round pin x 1 nos, Mounting Hardware screws x 50nosPreffered make : Netrack/ Valrack |
| 25 | OD296221/2025-2026:Supply and installation of 19inch 12U Network Rack with front lockable glass door, rear openable steel door, side integrated/welded panel, castors, 600W X 800D Includes Fan Module/2Fan/Tower mount/trays Power ist. Unit/Horz/6soc/6A/indian round pin x 1 nos, Mounting Hardware screws x 50nosPreffered make : Netrack/ Valrack |
| 26 | OD304221/2025-2026:Supplying and drawn of LSZH UTP 4 pair CAT 6 LAN cable in the existing surface/recessed steel/PVC conduit as required3 run of Cable.Make:- Molex/ Belden/ R&M/ Commscope |
| 27 | OD304222/2025-2026:Supplying and drawn of LSZH UTP 4 pair CAT 6 LAN cable in the existing surface/recessed steel/PVC conduit as required2 run of Cable.Make:- Molex/ Belden/ R&M/ Commscope |
| 28 | OD304223/2025-2026:Supplying and drawn of LSZH UTP 4 pair CAT 6 LAN cable in the existing surface/recessed steel/PVC conduit as required1 run of Cable. Make:- Molex/ Belden/ R&M/ Commscope |
| 29 | Part 2 - EPABX system |
| 30 | OD294910/2025-2026:Supply, installation, testing and commissioning of RJ 11 information outlet in good quality with shutter arrangement in front plate on recess/ surface metal/PVC mounting box .Preferred Make: Finolex, Krone, Legrand |
| 31 | OD294931/2025-2026:Supply and Drawing unarmored PVC insulated and PVC sheathed copper conductor 50 pair jelly filled Telephone Cable conforming to ITD specification through the existing trench in the soil-cable trace supporting system etc- as required. Make: Finolex/ Equivalent |
| 32 | OD295053/2025-2026:Supply, installation and testing of 50 pair Telephone Junction Box with KRONE connecting modules in a suitable M.S enclosure with Powder Coated paint of approved colour and lock and key arrangement on wall with suitable fixing arrangement and making necessary connections. Preferred Make: Krone |
| 33 | OD290786/2024-2025:Supply and Drawing unarmored PVC insulated and PVC sheathed copper conductor 20 pair jelly filled Telephone Cable conforming to ITD specification through the existing trench in the soil-cable trace supporting system etc- as required. Make: Finolex/ Equivalent |
| 34 | OD295054/2025-2026:Supply, installation and testing of 20 pair Telephone Junction Box with KRONE connecting modules in a suitable M.S enclosure with Powder Coated paint of approved colour and lock and key arrangement on wall with suitable fixing arrangement and making necessary connections. Preferred Make: Krone |
| 35 | OD295055/2025-2026:Supply, installation and testing of 10 pair Telephone Junction Box with KRONE connecting modules in a suitable M.S enclosure with Powder Coated paint of approved colour and lock and key arrangement on wall with suitable fixing arrangement and making necessary connections. Preffered Make: Krone |
| 36 | OD294913/2025-2026:Supply and Drawing unarmored PVC insulated and PVC sheathed copper conductor10 pair jelly filled Telephone Cable conforming to ITD specification through the existing trench in the soil-cable trace supporting system etc- as required. Make: Finolex |
| 37 | 1.18.2:Supplying and drawing following pair 0.5 mm dia FRLS PVC insulated annealed copper conductor,unarmored telephone cable in the existing surface/ recessed steel/ PVC conduit as required.2 Pair |
| 38 | Shifting of Audio video equipments from IT trainning hall (Ram Mohan palace)to Old AG building |
| 39 | OD296838/2025-2026: Supply and Installation of of gold plated connectors for S/FTP Cable for looping the Conferencesystem. Preferred make:- Molex/equivalent |
| 40 | OD296839/2025-2026:Supplying and drawn of S/FTP 4 pair LSZH CAT 6A LAN cable 23 AWG, RoHS compliant in the existing surface/recessed steel/PVC conduit as required1 run of Cable. Preffered Make: Actassi, Belden, Extron, Kramer, Molex, Panduit, R and M, Systimax. |
| 41 | OD297036/2025-2026:Supply, fixing, testing certification and documentation of spring shutter front access single ABS Faceplate with RJ 45 Module .(Delta Certified)Make/ AMP/Molex/Legrand. |
| 42 | 90.6.5.4:Supply and drawing the following sizes of multi-core PVC insulated & FRLS PVC sheathed 650/1100 V grade copper conductor round flexible cables conforming to IS 694 part I 1960 in the existing surface / recess conduit as required including giving necessary connections of the following sizes.2 core 1.50 sq mm |
| 43 | OD296865/2025-2026:Supply, Installation and laying of 2core Shielded PVC Insulated Microphone cable with Ultra low Capacitance 60(Pf/m) Outer Jacket PVC Matt WorkingTemperature:20degree C /+70degree C,Diameter: 6.5mm, extremally flexible as per the tender specifications.Preffered Make: Belden, Klotz, Gotham. |
| 44 | OD296984/2025-2026:Dismantling of existing electronic equipments such as video conferencing equipment, speakers, various displays, microphones, conference systems, LAN racks, and audio racks, along with all associated patch cables and accessories, from the IT Training Hall at Ram Mohan Palace, and the reinstallation of the same in the adjacent Old AG Building at the High Court of Kerala. Please Enable Macros to View BoQ information |