| 1 | (B/R PORTION )Excavating in post holes soft /loose soil (or similar holes) each n exc 0.5 cu. m, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm complete all as specified and as directed. |
| 2 | Excavation in trench not exceeding 1.5 M wide and not exceeding 1.5M in depth for sewage line, manhole etc not exceeding 10 sqm on plan and getting out in any type of soil complete all as specified and as directed. |
| 3 | Surface excavation soft/loose soil n.exc (not exceeding) 30 cm deep and averaging 15cm deep and getting out complete all as specified and as directed. |
| 4 | Returning, filling in, including spreading, watering and well ramming in layers n. exc 25 cm thick in any type of soil complete all as specified and as directed. |
| 5 | Removing excavated material to a distance n exc 50M and deposited where directed at a level n. exc 1.5M above the starting point complete all as specified and as directed. |
| 6 | M & LPCC 1:4:8 type D-2 using 40 mm graded stone aggregate as in sub base of floor complete all as specified and directed. |
| 7 | Demolition of brick work built in cement mortar including all quoins, arches, pillars etccomplete all as specified and directed. |
| 8 | M&L brick work with Fly ash bricks old size brick straight or curved on plan exc 6 m mean radius built in cement mortar 1:6 complete all as specified and directed. |
| 9 | M&L brick work with Fly ash bricks\" old size brick straight or curved on plan to any radius built in cement mortar 1:4 as in half brick thick wall complete all as specified and directed. |
| 10 | M & L100 mm thick PCC 1:2:4 type B-2 using 40 mm graded stone aggregate as in sub base of floor complete all as specified and directed. |
| 11 | M&L Hardcore of broken stone gauge n exc. 63 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and cm thick, watered and rammed to a true surface of broken stones complete all as specified and as directed. |
| 12 | M & LPCC 1:3:6 type C-2 using 40 mm graded stone aggregate as in sub base of floor complete all as specified and directed. |
| 13 | S&F rolled mild steel in roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc of Fe-410-W(Gde-E-250) quality-A complete all as specified and as directed. |
| 14 | S&F Steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.1161- 1979 grade St.-240 complete all as specified and as directed. |
| 15 | S & Fpre-paintedgalvatume aluminium zinc coating GI based corrugated steel 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws complete all as specified and as directed. |
| 16 | S & F pre-paintedgalvatume aluminium zinc coating GI based plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, ridges , valley gutter, Sun shed etcfixed with self tapping screws as specified. |
| 17 | M & L forheavy duty coloured ceramic floor tiles of size 300 x 300x 10 mm thick, suitable for high traffic external tiles, anti skid, scratch resistance and neutral to UV rays and acid alkali resistance as in floor including 15mm thick screed bed in cement mortar 1:4 complete all as specified anddirected. |
| 18 | M&L for 15mm thick rendering on fair faces of brick work or concrete surfaces in CM 1:4 finished rendering surfaces even and smooth (without using extra cement) complete all as specified and directed. |
| 19 | M & L two coats of cement based paint on newly plastered surface of wall including preparation and one coat of chalk whiteof serfaces complete all as specified and directed. |
| 20 | M & L applying two coats of synthetic enamel paint on steel surfaces of any description over 10 cm width or girth over a coat of red oxide primer including preparation of surfaces complete all as specified and as directed. |
| 21 | (E/M PORTION)Supply , installation and commissioning of 3 phase 415 Volts ,Air Cooled Vertical type Air conditioner energy efficient with minimum 3 star ratingindoor and Outdoor Complete with Cordless remote control unit , Scroll compressor of Capacity 3.0TR complete all as specified and directed : Make :- Model No. FVRN100AXV16 ofDaikin /Hitachi/O -General or equivalent make specified in tender. |
| 22 | Supply and draw submain wiring with four single core 10 sq mm FRLSPVC insulated copper cable 1100 volts grade multi stranded, un sheathed conductor in PVC Casing Cappingand10 sq mm multi-strand FRLS PVC insulated copper wire for earth continuity conductor connected to common earth dolly complete and making good disturbed surface complete all as specified and as directed. |
| 23 | Supply and laying refrigerant line copper tubing of size 5/8 \" with clamping on wall surface or concealed with both the ends connection complete all as specified and as directed. |
| 24 | All as per item Ser No 23 here - in - before but of size 3/8 \" |
| 25 | S&F Nitrile Rubber insulation for copper tubing of size 5/8\"\" diaduly wrapped complete all as specifed and directed. |
| 26 | S&F Nitrile Rubberinsulation for copper tubing of size 3/8\"\" dia duly wrappedcomplete all as specifed and directed. |
| 27 | S & F drain pipe 5/8\" dia PVC jacketed heavy duty with fixing of clampcomplete all as specifed and directed. |
| 28 | Supply and fixing angle iron bracketsbracings, supports, clamps, straps D-clamps, back plates and MS frames fabricated from structural steel sections such as MS channel, angle iron and flats of suitable size etc including nuts, ,bolts, washers eye hooks, welding, bending cold or hot drilling holes for bolts in any shape or size including two coats of synthetic enamel paint over a coat of red oxide primercomplete all as specified and directed |
| 29 | M&L for sheet metal enclosure for DBs SPN 4 way 240 V, with 200 A rated bus bar double door, complete flush mounted all as specified and as directed. |
| 30 | M&L for MCBFour Pole 240 volts 40 Amp capacity C Curve Complete all as specified and directed. Cat No.408700 of Legrandor equivalent make specified in tender. |
| 31 | Supply and fixing copper cable6.0sqmm 4 core duly connected and properly clampedfrom indoorunitto Outdoor unit complete all as specified and directed |
| 32 | Supply and lay pipe HPDE pipe of size 50 mm complete all as specified and directed . |
| 33 | Supply and lay pipe HPDE pipe of size 100 mm complete all as specified and directed. |
| 34 | Excavation/Cutting Road/ Hardstanding in Trenches not exc. 1.50 Metre wide and not exc. 1.50 Metre in depth and getting out, complete all as specified and as directed. NOTE : Quoted Unit Rate shall deem to be included Materials and Labour required for repairing to damaged Road/ Hardstanding to match the existing surfaces and specifications. |
| 35 | M&L Sand Cushioning (dry) in Trenches/Ducts for protection of UG Cables (below, above and around the UG Cable laid) of 23 Cm Spread thickness (8 Cm in depth before laying the Cable and 15 Cm in depth after laying the Cable) and consolidated (punned) upto 180Cm thickness, complete all as specified and as directed. NOTE : For the purpose of Payment, punned thickness of Sand Cushioning only will be Measured. |
| 36 | Supply & laying in Trenches Sub-class ‘B’ Bricks, kiln burnt, for Cable Protection, complete all as specified and as directed. |
| 37 | Taking out of interlocking paver block, any shape or size and Re-laying the same after laying of LT cable of any size and also removing all vegetation, algae, grass etc, laid to proper slope & gradient over sand cushioning complete all as specified and directed.NOTE : Sand, if required for connection of cushioning level will be measured and paid seperately. |
| 38 | Supply and Laying of Machine pressed precast concrete interlocking paver block with grey cement and pigment of any shape and size as approved by GE conforming to IS-15658-2006 of 60 mm thickness, M-35 gradewith 6 mm top layer of coloured rubberised anti abrasive material complete all as specified and directed. |
| 39 | Taking down unserviceable LT cable for repair/ replacement etc (from cable duct/underground trench/pole), stacking properly (cable, pipe and bricks) complete all as directed by the Engr-in-Chargeof the following cross - sections :-Note :-Necessary earth work to be measured and paid separately. |
| 40 | 240 Sqmm to 400 Sqmm, 3.5 Core |
| 41 | Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded,galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 240 sq mm 3.5 core |
| 42 | Relaying XLPE Under Ground Cable of any description (Serviceable Cable obtained from Item No. 6.00 here-in-before) 1100 Volt grade, after Fault rectification including necessary Aluminium Thimbles, jointing and Testing, complete all as specified and as directed of the following cross sectional area :- |
| 43 | 185 Sqmm to 240 Sqmm, 3.5 Core |
| 44 | S&F Heat shrinkable straight through Jointing Kit suitable for 1100 volts grade XLPE insulated stranded aluminium conductor cable including testing on completion complete all as specified and directed by the Engr-in-Charge for the following size of cables :- |
| 45 | 185 sqmm to 240 sqmm, 3.5 core |
| 46 | 300 Sqmm to 400 Sqmm, 3.5 Core |
| 47 | Demolition Cement Concrete (un-reinforced) in Ground Floors and Pavings not exc. 150mm thickness (above or below Ground Level), complete all as specified and as directed. |
| 48 | S&F PVC insulated unarmoured & PVC sheathed copper cable 3 core of cross sectional area 2.5 Sqmm for providing necessary electrical connection from Sheet metal enclosure to light fittings including with suitable size copper lugs complete all as specified and directed. |
| 49 | M&L for Backlid SS Letter of size upto 300 to 600 mm made of SS as per site requirement with Frontwith MANEKSHAW HOUSEletters in appropriate font size and other sides with Logo , duly prewired and including LED Strip light (Length of Strip Lights as per site requirement) inside the board incl necessary electrical connection fromSwitch board/PVC Junction Box with PVC Copper Cable 1.5 sqmm 3 core inside the PVC conduit Rigid/Flexible as per site requiremnt and Board fixed to the angle iron frame incl. necessary fixing arrangement such as angle iron, flat iron & channel complete all as specified and directed by Engr-in-charge.Note :-(i) Data to be writtenwill be directed by Engr-in-charge.(ii)Angle Iron, Channels, Flat Iron and Other Iron work is included in above rate. |
| 50 | S&F LED post top luminaire, 40 watt, with die cast aluminium spigot, spun aluminium powder coated top cover, with high power LED, IP 65 grade protection, designed with indirect symmetrical light distribution, with integrated constant current electronic driver incl taking down existing luminaire complete all as specified an directed.(Make : BAJAJ, Cat No: BGCT W4 LED WW / HALONIX, Cat No: HLPT-04-40-CW / SURYA, Cat No: SLE PT 40W-ETPP / Eveready, Cat No: LEDPOST045i3-01 / C&S, Cat No: CETUS-M/40W or equivalent model in other makes specified in particular specifications)NOTE: Wire for connection of luminaire shall be measured and paid separately. |
| 51 | M&L for preparation of old painted surfaces of steel tubular poles above PCC coping including cross arms, brackets, pole box and applying one coat of aluminium paint including cleaning of wild vegetation growth/ trimming of tree branches in the vicinity, writing of poles number with sentensile measure white Paint in Black base on steel tubular pole and two black and two yellow strip upto 1.20 metre height with synthetic enamel paint complete all as specified and directed. |
| 52 | Supply and fixing of LED Flood light fitting 150 watt, 5700 K,energy saving, environmental friendly, long life, exclusive innovative die-cast aluminium housing with dedicated heat sink and toughened glass and LEDs with individual secondary glass optics with better light distribution and control, IP66 degree of protection & impact resistance of IK-07 and integrated driver with 5/10 KV external surge protection complete all as specified. Make: Havells Cat Pt No : JETAIRISFL150WLED757ARNBLTG or equivalent Crompton/BAJAJ |
| 53 | S&F 3mm thick Aluminium Composite (Grade AL-33) for exterior cladding in any colour and PVDF Coated (minimum thickness of coating 35-50 micron on both faces) and to be fixed with aluminium square channel weighing shall not be less than 0.55 kg/length including necessary joining clamps, glazing clips etc on the floor/wall complete all as specified and directed |
| 54 | S&F LED Bollard light 9W, inverted pyramid tripod type luminaire with soft 360 degree light distribution, with IP 65 grade protection, operating voltage 120-280V, with integrated constant current electronic driver incl all fittings and fixtures complete with PCC work incl taking down existing luminaire complete all as specified and directed. (Make :CGL CAT NO- LBLSR 10-WW/PHILIPS CAT NO-BCP400LED09DCW PSU GR S1/ SURYA CAT NO- SLE BL 9W-BLK800or Equivalent modal in otherMakes specified in the tender) |
| 55 | Supply, Laying, jointing and testingXLPE insulated, screened PVC bedded, galvanised steel strip or wire armoured electric power cable 1100 Volts grade with stranded aluminium conductor cable, laid in trench or fixed to wall/passing through pipe/pole incl necessary thimbles complete all as specified and directed for the following sizes and cross sectional area :- (Note :-Necessary earth work to be measured and paid separately. |
| 56 | 10 Sqmm, 4 core |
| 57 | 16 Sqmm, 4 core |
| 58 | 25 Sqmm, 4 core |
| 59 | 35 Sqmm, 3.5 core |
| 60 | Note: Schedule of credit (SCHEDULE OF CREDIT)amount of Rs ________ mentioned on Page No ____ shall be deducted from the total quoted amount of BOQ.(Excavation returning and removing of soil shall be paid Item No 2,4,5 for E/M Portion) |