Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | Dismantling wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/slabs/blankets of any thickness, including cover fillets complete all as specified and directed by the Engg-in-Charge. |
| 2 | Dismantling of timber scantling fillets, rails, posts rafters, purlins etc under 40 Sqcm, in any position as in unframed work complete all as specified and directed by Engr-in-Charge. |
| 3 | S&F second clas soft wood fillets square or rectangular in section sectional area exceeding 13 sq cm and n exc 25 sq cm as in scantling secured with nails or brads complete all as specified and directed by the Engg-in-Charge. |
| 4 | S&F second class softwood fillets square, rectangular or triangular in section sectional area not exceeding 3 sqcm , clean sawn, secured with nails or brads bullnosed, splayed, chamfered or rounded on one edge or face as in cover fillets complete all as specified and directed by the Engg-in-Charge. |
| 5 | S&F second class softwood moulding as in cornices, picture rails and the like sectional area not exceeding 6 Sqcm fixed with nails complete all as specified and directed by the Engg-in-Charge. |
| 6 | S&F 12mm thick Prelaminated particle board, interior grade, prelaminated one side with decorative choice lamination & other side balancing white lamination, fixed with nails to timber frame work in walls complete all as specified and directed by the Engg-in-Charge. |
| 7 | S&F 9mm thick Prelaminated particle board, interior grade, prelaminated one side with decorative choice lamination & other side balancing white lamination, fixed with nails to timber frame work in ceiling or sloping portion complete all as specified and directed by the Engg-in-Charge. |
| 8 | Demolition of Stone slabs and tiles of any description or thickness in floors, aprons etc laid bedded and pointed in any mortar complete all as specified and directed by the Engg-in-Charge. |
| 9 | M&L for machine cut kota stone slab flooring 20-25mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and mirror polishing complete incl 20mm thick screed bedin CM 1:4 complete all as specified and directed by the Engg-in-Charge. |
| 10 | M&L for Kota stone slab 20-25mm thick in riser of steps, skirting, dado and pillar laid over cement screed and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and mirror polishing complete incl 15mm thick renderingin CM 1:4 complete all as specified and directed |
| 11 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified. |
| 12 | M&L for coloured glazed ceremic tiles in vertical surfaces 450x300x7mm thick, set & jointed in neat cement slurry and pointed in coloured cement to match coloured tiles laid over and including 15mm thick rendering in CM (1:4) complete all as specified and directed by the Engg-in-Charge. |
| 13 | M&L for coloured non-skid ceramic tiles 7 to 8mm thick (square/rectangle) area of each tile exc 0.06 sqm but not exc 0.11 sqm in floors etc set andset and jointed in neat cement slurry and pointed in white or coloured cement to match the work including 15 thick screed bed in CM ( 1:6) complete all as specified and directed by the Engg-in-Charge. |
| 14 | M&L for 25 mm thick plain cement concrete 1:2:4. type B-0 (using 12.5 mm graded aggregate) as subbase to flooring complete all as specified and directed by the Engg-in-Charge. |
| 15 | M&L for 75 mm thick plain cement concrete 1:3:6. type C-2 (using 40mm graded aggregate) as in plinth protection and subbase to floors complete all as specified and directed by the Engg-in-Charge. |
| 16 | Demolition ofconcrete of any (unreinforced) description and in anypositionand removal of rocks/debris to a distance not exc 50 mtrs and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and directed by the Engg-in-Charge. |
| 17 | Demolition of precast concrete articles andprecast concrete block walling including allquoins, arches, pillars, etc built in cement mortar of any description not other specifically provided for etc complete all as specified and directed by the Engg-in-Charge. |
| 18 | M&L for Precast cement concrete type C-1 block masonary with solid blocks 1:3:6 (using 20mm graded crushed stone aggregate) exc. 10cm in width and setting in cement mortar (1:6), complete all as specified and directed by Engr-in-Charge. |
| 19 | Taking down cement plaster or any description including raking outjoints, hacking for key, scrubbing down with water etc and removal of debris to a distance not exc 50 mts and depositing where directed complete all as specified and directed by the Engg-in-Charge. |
| 20 | M&L rendering 15mm thick cement plaster in cement mortor (1:4) finished even & fair withoutusing extra cement on brick/concrete surfaces complete all as specified and directed by the Engg-in-Charge. |
| 21 | M&L rendering 15mm thick cement plaster in cement mortor (1:6) finished even & smooth withoutusing extra cement on brick/concrete surfaces complete all as specified and directed by the Engg-in-Charge. |
| 22 | M&L for two coats of Oil bound distemperon new plastered surfaces of wallsover one coat of primerincludingpreparation of surfaces complete all as specified and directed by the Engg-in-Charge. |
| 23 | M&L for two coats of cement based paint on newly plastered surfaces of walls overone coat of primer includingpreparation of surfaces complete all as specified and directed by the Engg-in-Charge. |
| 24 | M&L for two coats of cement based paint on old plastered surfaces of wallsincludingpreparation of surfaces complete all as specified and directed by the Engg-in-Charge. |
| 25 | M&L for two coats of Oil bound distemperon old plastered surfaces of wallsincludingpreparation of surfaces complete all as specified and directed by the Engg-in-Charge. |
| 26 | S&F in repair galvanised mild steel wire cloth, 0.56 mm nominal dia of wire and average width of aperature 1.18 mm and fixed with tinned tacks, or galvanised wire staples including etc complete all as specified and directed by the Engg-in-Charge. |
| 27 | M&L for preparing old wooden surfaces of any description over 10cm width/girth and applying two coats of synthetic enamel paint complete all as specified and directed by the Engg-in-Charge. |
| 28 | M&L for preparing old steel surfaces of any description over 10cm width/girth and applying two coats of synthetic enamel paint complete all as specified and directed by the Engg-in-Charge. |
| 29 | S&F in repair curtain rails anodised aluminium alloy chromium plated with fixing brackets, stops, rollers etc. complete all as specified and directed by the Engg-in-Charge. |
| 30 | Hacking out old broken glass (any thickness,size,quality or description) from wooden frames metal frames or stone,concrete or brick surrounds,glazed with putty or fixed with beads complete all as specified and directed by the Engg-in-Charge. |
| 31 | S&F 3mm thick sheet glass ordinary quality and glazing with oil putty in squares n.exc 0.5 Sqm in each pane complete all as specified and directed by the Engg-in-Charge. |
| 32 | Demolition ofcement concrete (reinforced) of any description and in anyposition complete all as specified and directed by the Engg-in-Charge. |
| 33 | M&L for precast cement concrete type B-1 (1:2:4) using 20mm graded stone aggregates as in lintels, landings, coverslabs (for man holes etc.) chullah hoods, chajjas, water troughs, mangers, shelves and similar articles with plain faces set in CM 1:4 complete all as specified and directed by the Engg-in-Charge. |
| 34 | M&L for Mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, ending spirally for hooping forcolumns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed by the Engg-in-Charge. |
| 35 | M&L PCC (1:4:8) type D-2 using 40mm graded stone aggregate as infoundations, mass filling, sub base and the like complete all as specified and directed by the Engg-in-Charge. |
| 36 | M&L PCC (1:2:4) type B-2 using 40mm graded stone aggregate as insurface channels and drains complete all as specified and directed by the Engg-in-Charge. |
| 37 | Taking up or down existing GI tubing and connections, including cleaning for refixing and making good the disturbed surface for 20mm dia pipes complete all as specified and directed by the Engg-in-Charge. |
| 38 | Taking up or down existing GI tubing and connections, including cleaning for refixing and making good the disturbed surface for 25 mm dia pipes complete all as specified and directed by the Engg-in-Charge. |
| 39 | S&F 20mm outer diameter 3-layer PP-R (polypropylene random copolymer) concealed pipes SDR 7.4 (PN16) UVstabilized and antimicrobial fusion welded having thermal stability for hot & cold water supply including all PP-R plain & brass threaded polypropylene random fittings fixed complete to walls, ceilings or in floors etc complete all as specified and directed by the Engg-in-Charge. |
| 40 | All as per Srl Item No.39 above but 25mm outer diameter complete all as specified and directed by the Engg-in-Charge. |
| 41 | S&Fin repair 15 mm bore bib taps standard of PTMT any colour high pressure screwed for iron pipe and fixed. (Minimum weight 15mm-90gms) complete all as specified and directed by the Engg-in-Charge. |
| 42 | S&F in repair Vitreous china wash down water closet pan orissa pattern size 580x440mm (Pedestal pattern), white (excluding fixing bolts, flushing cistern and flush pipe) complete all as specified and directed by the Engg-in-Charge. |
| 43 | S&F in repairs 10 ltrs capacityPVCvalveless syphonic action typelow level flushing cistern complete with syphone handle lever PVC bend including connecting to WC and fixing on walls with bracket complete all as specified and directed by the Engg-in-Charge. |
| 44 | S&F in repair 15mm bore PVC connection 600mm long both ends screwed with brass cap complete all as specified and directed by the Engg-in-Charge. |
| 45 | S&F Vitreous China bowl urinal flat back, size of 465x355x 265 mm white (minimum), with grating and union for discharge pipe (excluding flushing cistern, flush pipe and waste pipe) complete all as specified and directed by the Engg-in-Charge. |
| 46 | S&F in repairs 75mm bore PVC (SWR) floor trap, plain with grating including jointing with solvent cement complete all as specified and directed by the Engg-in-Charge. |
| 47 | S&F in repair brass CP tubular towel rail, 20mm dia, D type, 60cm long between flanges complete all as specified and directed by the Engg-in-Charge. |
| 48 | Taking down PVC pipe, eaves and gutters(any size or pattern), including all fittings, heads, shoes, bends, swan-necks, etc., including cleaning or refixing or removal to store (measured overall as fixed along the centre line over fittings and accessories) complete all as specified and directed by the Engg-in-Charge. |
| 49 | S&F 110mm bore PVC (SWR) pipes single socketed,inanylength with rubber ring joints,laid intrenchesorin floors complete all as specified and directed by the Engg-in-Charge. |
| 50 | S&F 75mm bore PVC (SWR) junction single, (Single T) equal or unequal oval acess door complete all as specified and directed by the Engg-in-Charge. |
| 51 | S&F 110mm bore PVC (SWR) bends with oval access doorany radius complete all as specified and directed by the Engg-in-Charge. |
| 52 | S&F 110mm bore PVC (SWR) junction single, (Single T) equal or unequal with oval acess door complete all as specified and directed by the Engg-in-Charge. |
| 53 | S&F 75mm bore PVC (SWR) pipes single socketed,inanylength with rubber ring joints,laid in trenches or in floors complete all as specified and directed by the Engg-in-Charge. |
| 54 | S&F 75 mm bore PVC (SWR) junction single, (Single T) equal or unequal oval acess door complete all as specified and directed by the Engg-in-Charge. |
| 55 | Dismantling PVC water tanks of capacity exc 500 but n exc 1000 ltr and removing to store complete all as specified and directed by the Engg-in-Charge. |
| 56 | S&F 1000 ltr capacity rotationally moulded polythene water storage tanks (cylindrical vertical with closed top) multilayers layers of approved make hoisted & fixed at position complete all as specified and directed by the Engg-in-Charge. |
| 57 | S&F in repairs 600mmx450mm bevelled edge mirror of selected quality glass, mounted on 6mm thick AC building board or commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers complete all as specified and directed by the Engg-in-Charge. |
| 58 | S&F in repair 15mm bore dia angle valves of PTMT any colour high pressure screwed for iron pipe and fixed. (Minimum weight 15mm-90gms) complete all as specified and directed by the Engg-in-Charge. |
| 59 | M&L for Surface dressing n.exc 15cm deep and getting out hard/dense soil complete all as specified and directed by the Engg-in-Charge. |
| 60 | Excavating in trenches, nexc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. nexc 10 sq m on plan and n exc1.5 m in depth and getting out in hard dense soil complete all as specified and directed by the Engg-in-Charge. |
| 61 | M&L for M-25 grade cement concreteusing 20mm graded stone aggregates as inFoundations, including rafts,footings,foundation beams, plinth beams; bases for columns, etc. basement slabs,under-reamed piles and mass concrete complete all as specified and directed by the Engg-in-Charge. |
| 62 | M&L for M-25 grade cement concreteusing 20mm graded stone aggregates as inColumns, pillars, piers, posts and struts complete all as specified and directed by the Engg-in-Charge. |
| 63 | M&L for M-25 grade cement concreteusing 20mm graded stone aggregates as inBeams, cantilevers, bressummers, lintels over 1.5m span complete all as specified and directed by the Engg-in-Charge. |
| 64 | M&L for Flat rough finished form work to side of concrete foundations,footings, bases of coloumns, raft and raft beam, sides and soffits (if any) of foundation and plinth beams orsimilar works.etc complete all as specified and directed by the Engg-in-Charge. |
| 65 | M&L for Flat rough finished form work to side of pillars, posts, struts, piers, columns and stanchions.etc complete all as specified and directed by the Engg-in-Charge. |
| 66 | M&L for Flat rough finished form work to sides and soffits of floor or roof beams, beam haunchings girders, bressummers, lintels, cantilevers, shelves including sup-ports, overhangs, etc. also splays between floors and beams, etc complete all as specified and directed by the Engg-in-Charge. |
| 67 | All as per Srl Item No.34 above but 5mm dia and over upto and incl 10mm dia as in strirups, spaces and binder etc complete all as specified and directed by the Engg-in-Charge. |
| 68 | M&L for preparation of newly plastred surfaces of walls and applying three coats of white wash complete all as specified and directed by the Engg-in-Charge. |
| 69 | Returning, filling of hard / dense soilincl spreading, levlling, watering and well ramming in each layer n.exc 25 cm thick complete all as specified and directed by the Engg-in-Charge. |
| 70 | Removal of surplus rock to a distance not exceeding 50m and deposting where directed at a level not exceeding and depostiting where directed at a level not exceeding 1.50m above complete all as specified and directed by the Engg-in-Charge. |
| 71 | Earth filling in floors or paving including spreding, levelling and ramming with watering as required in layers n.exc 25cm thick complete all as specified and directed by the Engg-in-Charge. |
| 72 | M&L for broken stone or boulders as in hardcore of gauge not exc 63mm deposited, spread and levelled in layers not exc 15cm thick watered and rammed to a true surface complete all as specified and directed by the Engg-in-Charge. |
| 73 | S&F Rolled mild steel Gde Fe-290 (Gde Fe 165) as in Roof trusses (framed), trussed, purlins crane gantries, rails & fastenings & heavy brackets framimg (Beam, tee, angle, channel or flat section) including distance pieces, cleats etc complete all as specified and directed by the Engg-in-Charge.. |
| 74 | M&L for preparation of newly untreated steel / iron surfaces of any description over 10cm in width or girth not otherwise described and painting two coat of synthetic enamel paint over a coat of red oxide zinc chrome complete all as specified and directed by the Engg-in-Charge. |
| 75 | S&F for Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering / cladding to wall, fixed with self tapping screws complete all as specified and directed by the Engg-in-Charge. |
| 76 | S&F for Pre- painted galvalume aluminum zinc coating GI based plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed by the Engg-in-Charge. |
| 77 | S&F solid PVC door frame of size 50x47mm made out of 5mm thickPVC sheetreinforced with mild steel square tube complete all as specified and directed by the Engg-in-Charge. |
| 78 | S&F Factory made solid panel PVC door shutter 30mm thick (style) consisting of frame made out of M.S tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, suppling & fixingcomplete all as per specification and directed. |
| 79 | S&F 75mm butt higes medium weight cold rolled mild steel fixed with screws or welded complete all as specified and directed by the Engg-in-Charge. |
| 80 | S&F 100mm long alluminium anodized, barrel tower bots exturded section & fixed complete all as specified and directed by the Engg-in-Charge. |
| 81 | S&F aluminium handles cast type anodised size100mm complete all as specified and directed by the Engg-in-Charge. |
| 82 | S&F Steel windows with side hung shutters including projecting type hinges with steel handle, and steel peg stay, complete with glazing bars, dovetailed or welded complete all as specified and directed by the Engg-in-Charge. |
| 83 | S&F Vitreous china wash down water closet pan orissa pattern size 580x440mm (Pedestal pattern), white (excluding fixing bolts, flushing cistern and flush pipe) complete all as specified and directed by the Engg-in-Charge. |
| 84 | S&FVitreous china wash basin,white,angle back with pedestal, size 600x480mm excluding taps, waste chain and plug and porcealin stopper but incl brackets complete all as specified and directed by the Engg-in-Charge. |
| 85 | S&F Gun metal globe or gate valve with iron wheel head secrewd bolt ends for iron pipe and fixed of 20mm bore dia complete all as specified and directed by the Engg-in-Charge. |
| 86 | S&F Towel rail 600 mm long PTMT fixed with and incl chromium plated brass screws and wooden/ plastic cleats complete all as specified and directed by the Engg-in-Charge. |
| 87 | S&F bib tap 15 mm bore chromium plated copper alloy with crutch or butterfly handle screwed donw screwed for iron pipe or brass ferrule complete all as specified and directed by the Engg-in-Charge. |
| 88 | S&F Stop valves/Angle Cock cast copper alloy, screw down high pressure with crutch or butterfly handly for 15mm bore pipe complete all as specified and directed by the Engg-in-Charge. |
| 89 | S&F pillar tap 15mm bore chromium plated screwed down, thigh pressure with or without lettered (hot or cold) with long screwed shkes and fly nuts scrrewed complete all as specified and directed by the Engg-in-Charge. |
| 90 | S&F for waste coupling of PTMT (half or full threaded) 32mm dia for basin/ urinal complete all as specified and directed by the Engg-in-Charge. |
| 91 | S&F PVC (SWR) bends any radius 75mm dia complete all as specified and directed by the Engg-in-Charge. |
| 92 | S&F 75mm bore PVC (SWR) pipes single socketed,inanylength with rubber ring joints, fixed to walls complete all as specified and directed by the Engg-in-Charge. |
| 93 | M&L for provn of Soakage well incl excavation, in any type of soil, foundation in PCC 1:3:6, walls of honey combed masonry with top ring of M25 concrete including intercepting chamber and screen chamber made of brick masonary in CM (1:6), RCC cover slab in M25/SFRC cover, interconnecting pipes RCC/DWC complete filled with brick bats of size nexec 63mm complete all as specified and directed by the Engg-in-Charge. |
| 94 | S&F in repair 20 mm Cast copper alloy, Chromium PlatedBib tap fancy type with crutch or butterfly handle, screwed for iron pipe or for brass pipe of for ferrule and fixed complete all as specified and directed by the Engg-in-Charge |
| 95 | S&F 20mm dia PP-R Gate valves (brass insert) as per requirement of the site complete all as specified and directed by the Engg-in-Charge |
| 96 | S&F in repair soap dish brass chromium plated fixed to wall with brass chromium plated screw complete all as specified and directed by the Engg-in-Charge |
| 97 | Taking down chowkats or frame with shutter (without taking out shutter from the frame) not exceeding 1.50 sqm each as doors, windows & ventilators etc and removal from site complete all as specified and directed by the Engg-in-Charge |
| 98 | M&L for second class softwood (KAIL), plain, solid, straight chowkats and frames, wrought, framed rebated on the solid, rounded or chamfered, put together with glue pinned at joints complete all as specified and directed by Engr-in-Charge. |
| 99 | S&F second class soft wood (KAIL) plain, framed, panelled shutters (any number of panels), 35mm thick with panels of 9mm ply BWP commercial type or 12 mm thich of veneered particle board with commercialveneering both faces as in doors complete all as specified and directed by the Engg-in-Charge |
| 100 | S&F mild steel 100mm long Butt hinges medium weight, cold rolled with galvanised mild steel screws complete all as specified and directed by the Engg-in-Charge |
| 101 | S&F Aluminium anodised handles, cast type anodised 125 mm long complete all as specified and directed by the Engg-in-Charge |
| 102 | M&L for two coats of oil bound distemper on newly plastered surfaces of walls over a coat of 1mm thick wall care putty including preparation of surfaces complete all as specified and directed by the Engg-in-Charge |
| 103 | M&L Concrete bed to drain pipe in PCC (1:4:8) Type-D-2,using 40 mm graded stone aggregate including packing under and haunching against the sides of pipes after they are laid and tested, for 100mm bore of pipe (Earth work shall be measured and paid separately) complete all as specified and directed by the Engg-in-Charge |
| 104 | S&F 75mm bore PVC (SWR) reducers complete all as specified and directed by the Engg-in-Charge |
| 105 | S&F 75 mm bore PVC (SWR) vent cowl complete all as specified and directed by the Engg-in-Charge |
| 106 | M&L for Mild steel bars 6 to 8mmdia and over, cut to length, bent to shape required, including cranking, ending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed by the Engg-in-Charge |
| 107 | M&L for proving PCC type C1 (1:3:6 using 20mm graded aggeregate) in coping incl necessary formwork complete all as specified and directed by the Engg-in-Charge |
| 108 | Removing excavated material exc.250m andn.exc 500 m and depositing where directed in soil complete all as specified and directed by the Engg-in-Charge |
| 109 | S&F 0.63mm thick galvanised, corrugated mild steel sheeting with two corrugations side lap, fixed with L-type or J-type or cranked hook bolts and washers in roofs, walls in curve shape etc. with grade of zinc coating 275 complete all as specified and directed by the Engg-in-Charge |
| 110 | S&F 0.63 mm thick Plain, galvanised, mild steel sheeting, in ridges, hips, valley gutters, drip and straight flashings (length and girth as fixed) with grade of zinc coating 275 fixed in roof, wall etc complete all as specified and directed by the Engg-in-Charge |
| 111 | S&F Steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to IS.1161:1979 (grade St.-240) quality- A complete all as specified and directed by the Engg-in-Charge |
| 112 | S&F MS Plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes with riveted, bolted or welded attachment Fe-410-W(Gde-E-250) quality- B complete all as specified and directed by the Engg-in-Charge |
| 113 | Excavating in post holes (or similar holes) each n exc 0.5 cum incl getting out, returning/filling in and ramming earth or broken rubble mixed with earth around in layers not exceeding 25cm complete all as specified and directed by the Engg-in-Charge |
| 114 | S&F 150 mm aluminium anodised barrel tower bolts of extruded section complete all as specified and directed by the Engg-in-Charge |
| 115 | S&F 25mm dia PP-R Gate valves (brass insert) as per requirement of the site complete all as specified and directed by the Engg-in-Charge |
| 116 | M&L for Taking down carefully copper or aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches ceiling roses, pendants,sockets bulk, head fitting, tube light fitting by unscrewing carefully from boards etc and making good, distrubed surface of walls floors etc complete all as specified and directed by the Engg-in-Charge |
| 117 | M&L for Point wiring for light/fan/bell with FRLS cable of 1.5sqmm PVC insulated (red/blue/yellow for phase, black for neutral and green for earth) unsheathed multistranded copper conductor 1100 volts grade in and including not less than 2mm thick PVC casing capingwith all accessories and 1.5sqmm green in colour PVC insulated multistranded copper conductor FRLS cablefor earth continuity connected to common earth dolly incl MS/GI sunken box with 3mm thick pre laminated hylum sheet/PVC box with back plate,flush/surface type for mounting fittings such as switches,socket,and regulator complete all as specified and directed for one light point or bell/buzzer pointcontrolled by one switch. |
| 118 | All as per Srl item No 117 above but using cable size 2.5 Sqmm for one 3 pin socket outlet 5 Amps independent board complete all as specified and directed by the Engg-in-Charge |
| 119 | All as per Srl item No 117 above but using cable size 2.5 Sqmm for one 3 pin socket outlet 15 Amps independent board complete all as specified and directed by the Engg-in-Charge |
| 120 | S&F Switch piano flush type 5 Amps, single pole one way complete all as specified and directed by the Engg-in-Charge |
| 121 | S&F Switch socket combination 2 in 1, and 3 and 2 pin, 5 Ampsflush type complete all as specified and directed by the Engg-in-Charge |
| 122 | S&F Switch socket combination 2 in 1, 5 and 15 Ampsflush type complete all as specified and directed by the Engg-in-Charge |
| 123 | S&F ceiling rose on PVC square blocks surface bakelite 3 terminal complete all as specified and directed by the Engg-in-Charge |
| 124 | S&F LED lights fitting, surface mounting general purpose ultra slim economical LED batten of 1x18W/20W, lumen out put 100lm/wattt, CCT:6500K/3000K, PF>0.9, in extruded PC housing and round/square shaped diffuser including connecting up with two core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed by the Engg-in-Charge |
| 125 | S&F in replacement exhaust fan made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, Copper winding of sweep 250 mm including making arrangement for fixing complete all as specified and directed by the Engg-in-Charge |
| 126 | S&F in replacement 440V 10 KA C curve (MCB) TPN 40 to 100 Amp in the DB complete with making connection testing complete all as specified and directed by the Engg-in-Charge |
| 127 | S&F in replacement Sheet metal enclosure for DB\"s (TPN BD) Double door, triple pole and neutral, 440V/4 way with 200 Amp rated bus bar including blanking plates where required complete all as specified and directed by the Engg-in-Charge |
| 128 | S&F in replacement Sheet metal enclosure for DB\"s Double door,single pole and neutral, 240V, 12 way with 200 Amp rated bus bar including blanking plates where required. complete all as specified and directed by the Engg-in-Charge |
| 129 | S&F in replacement Sheet metal enclosure for DB\"s Double door, single pole and neutral, 240V, 4 way with 200 Amp rated bus bar including blanking plates where required. complete all as specified and directed by the Engg-in-Charge |
| 130 | S&F in replacement 240V, 10KA C curve (MCB) SPN 40 to 63 Amp in the DB complete with connection testing complete all as specified and directed by the Engg-in-Charge. |
| 131 | S&Fin replacement 240V, 10KA C curve (MCB) SPN 32 Amp in the MCB DB with connection testing complete all as specified and directed by the Engg-in-Charge. |
| 132 | S&F in replacement 240V, 10KA C curve (MCB) SP 5 to 32 Amp in the DB complete with connection testing complete all as specified and directed by the Engg-in-Charge. |
| 133 | S&F LED flood light 70 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp complete all as specified and directed by the Engg-in-Charge. |
| 134 | M&L for Submain wiring comprising single core, 2 Runs of 6.0 Sqmm nominal cross sectional area multi stranded FRLS copper coonductor cable, PVC insulated unsheathed 1100 Volts grade drawing in and including min 25mm dia. PVC conduit/ PVC Casing CapingISI Marked (heavy duty) and its fittings on surface/recessed complete including 1x6.0 Sqmm nominal cross sectional area mutli stranded FRLS copper conductor cable, PVC insulated unsheathed 1100 volts grade as earth wire and using color code as per IS including taking down UNSV submain wiring and making good the disturbed surface complete all as specified and directed by the Engg-in-Charge.(Note: Extra length of cables/ wire required for connection to MCBs shall not be paid seperately and the rate quoted by contractor for per unit shall be deemed accordingly) |
| 135 | M&L for Earthing complete with galvanised steel earth plate electrode 60cm×60cm×6.0mmthick, buried directly in ground vertically (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to galvanised earth lead wire 4.0mm dia by means of bolts, nuts, check nuts and washers made out of galvanised iron or steel and connected to main switch board or equipment, including watering arrangement with GI medium grade 20mm bore watering pipe with funnel and wire mesh with PCC chamber CI cover with frame including 15mm dia GI pipe light grade for protection of earthing lead etc including necessary excavation in any type of strata, returning, filling, removal of soil outside MD land, filling of charcoal and salt complete all as shown in electrical plate No. 3 of MES Sch Part I, connected to earthing test point all as specified or indicated including testing on completion.Notes : (i) Earth continuity conductor including protection pipe upto 7.5 meters from earth electrode will be include in unit rate, (ii) Arrangement for earth resistance test should be carried out by the contractor. No extra payment shall be provided for the same. |
| 136 | Supply, fixing incl testing of cross linked polytehylene (XLPE) LT cable XLPE insulated, PVC inner sheathed, bedded, galvanised steel strip or wire armoured heavy duty 1100 V grade with stranded aluminium conductor having cross sectional area 25 Sqmm 4 core and conforming to IS-7098(Part-I-1988 & as per latest amendments), laid in trench/ducts/through pipes/in floors/under roads/under hard standing/along poles including taking down of existing cable complete all as specified and directed by the Engg-in-Charge |
| 137 | S&F GI tubing light grade 40mm bore as in cable protection fixed to poles/walls or laid in trenches/under road crossing etc. complete all as specified and directed by the Engg-in-Charge |
| 138 | Supply, laying or fixing and testing of DWC (Double Wall Corrugated) duct pipe (HDPE) of size 90 x 76 mm laid in trench/ducts/under roads/under hard standing/along poles complete all as specified and directed by the Engg-in-Charge. |
| 139 | S&F Sheet metal enclosure for DB\"s Double door,single pole and neutral, 240V, 8 way with 200 Amp rated bus bar including blanking plates where required complete all as specified and directed by the Engg-in-Charge. |
| 140 | S&F of 240V, 10 KA C curve (MCB) SPN 20 Amp in the DB complete with connection testing complete all as specified and directed by the Engg-in-Charge |
| 141 | Supply, laying or fixing and testing cross linked polytehylene (XLPE) LT cable XLPE insulated, PVC inner sheathed, bedded, galvanised steel strip or wire armoured heavy duty 1100 V grade with stranded aluminium conductor having cross sectional area 16 Sqmm 2 core and conforming to IS-7098(Part-I-1988 & as per latest amendments), laid in trench/ducts/through pipes/in floors/under roads/under hard standing/along poles complete all as specified and directed by the Engg-in-Charge |
| 142 | Supply, laying or fixing and testing of DWC (Double Wall Corrugated) duct pipe (HDPE) of size 63 x 50 mm laid in trench/ducts/under roads/under hard standing/along poles complete all as specified and directed by the Engg-in-Charge. |
| 143 | S&F in replacement1100 volts grade heavy duty 16 Sqmm 2 core flat cable PVC insulated aluminium standard conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections complete all as specified and directed by the Engg-in-Charge. |
| 144 | S&F in replacement LED light fitting mirror type with high output diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed by the Engg-in-Charge. |
| 145 | Note : Deduction for amount of Rs. 35425.00 as listed in Schedule \"A\" Part-II (Schedule of Credit) shall be made while awarding of contract. |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy