| 1 | Demolition of Cement concrete (unreinforced) in ground floor and pavings not exc 15 cmthickness (below or above ground level) complete all as specified and directed. |
| 2 | M&L for moorum/red bajri filling in floors or pavings laid in layers n exc. 15 cm thick,spread,leveled and rammed including watering complete all as specified and directed. |
| 3 | M& L for broken bricks hardcore of gauge n exc. 63 mm ,deposited ,spread and leveled in layers n exc 15 cm thick ,watered and rammed to a true surface complete all as specified and directed |
| 4 | M&L for cement concrete type D2 1:4:8 in sub base of floors 50 mm thick complete all as specified and directed. |
| 5 | S&F framed work such as grills, gratings, etc.with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165 complete all as specified and directed. |
| 6 | Taking down Chowkhats or frames exc 1.5 sq. m but n exc 4 sq. m each complete all as specified and directed. |
| 7 | Taking down Chowkhats or frames n exc 1.5 sqm complete all as specified and directed. |
| 8 | Demolition of brickwork built in cement mortar with all quinces the cleanly etc complete all as specified and as directed. |
| 9 | M&L brick work with modular fly ash bricks straight or curved on plan exc 6m mean radius wall built in cement mortar 1:6 complete all as specified and as directed. |
| 10 | Material & labour for brick work with sub class ‘B’ fly ashbricks, straight or curved on plan, exc. 6 metre mean radius built in CM(1:4)as in half brick thick walls complete all as specified and directed. |
| 11 | Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick, flat, fair finished surfaces of concrete, complete all as specified and directed. |
| 12 | M&L Formwork to sides and soffits of floor or roof beams, beam haunch- ings, girders, bressummers, lintels, cantilevers, shelves including sup- ports, overhangs, etc. also splays between floors and beams, etc. for fairfinished surfaces of concrete, complete all as specified and directed. |
| 13 | M&L for RCCM-20 (Design Mix) using 20mm graded crushed stone aggregate, as in slabs supported on walls, beams and columnsetc complete all as specifiedand directed. |
| 14 | M&L for RCC M-20 (Using 20 mm graded stone aggregate) as In beams,cantilever,bressumers,lintels over 1.5 mm span etc complete all as specified and directed. |
| 15 | M&L for mild steel TMT bars10 mm dia and overas in reinforcement for concrete, cut to length, bent to shape required, including cranking, bending, hooking ends and binding with mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed. |
| 16 | Ditto all as per item No 15 herein beforebut 6 mm to 8 mm dia quality conforming to TMT bars Fe 500/ Fe 500D complete all as specified and directed. |
| 17 | M&L for mild steel TMT bars 5 mm dia and over upto and including 10 mm dia as in stirrups, spacers and binders for concrete, cut to length, bent to shape required, including cranking, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia complete all as specified and directed. |
| 18 | M&L for rendering 12mm thick plaster on internal surfaces of wall in CM 1:6 on fair faces of brick or concrete surfaces finished smooth and even without using extra cement complete all as specified and as directed. |
| 19 | Material & labour for 5 mm thick plaster in CM 1:3 on ceiling surfaces, surfacesfinished even and smooth without using extra cement complete all as specified and directed. |
| 20 | M&L for applying wall care putty 2mm thick and application of two coats of distemper, oil emulsion,white or tinted, on smooth and evensurfaces of wall complete all as specified and directed. |
| 21 | Demolition of stone slabs and tiles of any description or thickness in floor,aprons etc. complete all as specified and directed. |
| 22 | M&L machine cut kota stone slab flooring 20-25 mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of slab including rubbing and polishing complete all as specified and directed. |
| 23 | M&L for machine cut kota stone slab as in skirting/ vertical surface, 15-18mm thick over & including 10mm thick rendering in CM (1:4) laid and jointed with gray cement slurry mixed with pigment to match the shade of the slab including rubbing andmirror polishing complete all as specified & directed. |
| 24 | M& L for two coat of oil bound distemper with chalk whiting incl preparation of new surface of wall complete all as specified and as directed. |
| 25 | M&L for one coat of oil bound distemper white/coloured or tinted on old decorated surfaces of walls including preparation of surface by washing rubbing down and stopping of distempered surfaces complete all as specified and directed by Engineer-in-Charge. |
| 26 | M&L for preparation of old decorated plastered surfaces of ceilling and applying one coat of white washing on ceilling complete all as specified and directed by Engineer-in-Charge. |
| 27 | M&L for preparation of new plastered surfaces and applying two coats of exterior acrylic paint of any shade in comouflaged pattern as approved by GE as per manufacturers instruction complete all as specified and directed by engineer in charge. |
| 28 | M&L for Priming surfaces and applying normal treatment (for moderate conditions) using glass fibre base bitumen felt, grade 2, based solvent primer @ 0.3 Kg / Sqm complete all as specified and as directed. |
| 29 | M&L for Applying evenly a tack coat of industrial bitumen 85/25 grade @ 1.2 kg/ Sqm includingcleaning surfaces complete all as specified and as directed. |
| 30 | M&L for unrolled over the bitumen coated surface, 3mm thickspun bonded non-woven polyester reinforced APP modified water proofing membrane weighing not less than 3.0 Kg/Sqm with minimum side over lap of 100mm and end over lap of 150 mm shall be sealed by flame as per manufacturer\"s instructions complete all as specified & directed.Note:- Suitable embedment of APP modified water proofing membrane shall be ensured into walls/parapet walls, special care shall be taken in laying APP modified water proofing membrane in situations such as drain/ expansion joints etc. complete all as specified and directed. |
| 31 | Excvn in trenchesnot exceeding 15mm depth and not exceeding 1.5m in with in any type of soil and getting out in soft/loose soils complete all as specified and directed |
| 32 | Returning filling in soil including spreading leveling watering and well runningin layers not exceeding 25 cum all as specified. |
| 33 | Removal of surplus soil not exceeding 50m and at a level not exceeding 1.5m above the starting point and depositing |
| 34 | PCC M-15 (nominal mix) using40mm graded stone aggregate type (1:2:4) in foundations filling and mass concrete. |
| 35 | Rendering 10mm thick on fair face of brick work or concrete surface in CM 1:4 finished even and smooth without using extra cement. |
| 36 | S & F steel window side hung shutters incl projecting type hinges with steel handles, peg stay guard bars & shutters, complete with glazing bars, steel conforming to IS-1038 all as specified. |
| 37 | PCC M-15 (Nominal mix) using 20mm graded stone aggregate as in cill complete all as specified and directed. |
| 38 | RCC M-25 design mix) in stabs supported on walls beams and columns in floors, roofs, landings, balcony, canopies, deck slabs and in salves and like complete all as specified and directed. |
| 39 | RCC M-25 design mix as in fdn, including raft, fooling fdn beams plinth beams bases for columns complete all as specified and directed. |
| 40 | Form work to sides of concrete fdn footing base of columns and raft beams sides and soffits (if any) of plinth beams complete all as specified and directed. |
| 41 | Form work to edges of concrete Hat, treads, window cills etc complete all as specified and directed. |
| 42 | M&L painting with synthetic enamel paint two coats over a coat of red oxide promer including preparing the new untreated steel surfaces of any description over 10cm in width or girth complete all as specified and directed. |
| 43 | M&L three coats of white wash including preparing the new surface complete all as specified. |
| 44 | Ditto all as per above item No 43 above but on ceilings. |
| 45 | Moorum/red Bajri filling in floors in layers not exceeding 15cm thick spread leveled and rammed including watering complete all as specified. |
| 46 | M&L cement concrete in sub base 1:5:10 (40mm) graded stone aggregate 100mm thick complete all as specified and directed. |
| 47 | PCC M-15 (Nominal mix) 40mm thick as in floors using 20mm graded stone aggregate as in floors finished concrete surface even and smooth using extra cement complete all as specified and directed. |
| 48 | Excavation post holes or similar works, each n exc. 0.5 Cum, getting out Soft/ loose soill. Returning,filling in and ramming earth or broken rubble mixed with earth around, in layersn.exc. 25 cm and watering and removing surplus soil to adistance not exceeding 50m and making good surfaces complete all as specified and directed. |
| 49 | Material and labour for precast RCC fencing posts with M-30 ConcreteUsing 20mm graded aggregate) sectional area exc. 100 but n.exc. 250 Sq cm complete all as specified and directed. |
| 50 | PCC type D2 1:4:8 (Using 40mm graded stone aggregate) in fdn filling and mass concrete complete all as specified and directed. |
| 51 | Fixing only chain link fencing complete all as specified and directed. |
| 52 | Supply and Fix mild steel bolts, purpose made,with hexagonal or square headed one end and screwed the other, or screwed the both ends and each end to be fitted with washers and one hexagonal or square nut n.exc 12m dia and 300 mm long complete all as specified and directed. |
| 53 | Supply and Fix mild steel angles.bars, flats etc as in supports for stiffening of fencing wall ties, hold fasts, clamps and similar small articles conforming to Fe 290 complete all as specified and directed. |
| 54 | Preparation of new or previously untreated steel surfaces of any description n.exc. 10cm width or girth ,not otherwise described and applying two coats of synthetic enamel paintover a coat of red oxide zinc chrome primer complete all as specified and directed. |
| 55 | M&L for 450 mm dia cross type BTO-10.15.22 Concertina coil securing or type incl provison of MS wie stepples or steel pin etc complete all as specified and directed. |
| 56 | Supply and Fixing Galvanised 2 strand, steel barbd wire 2.24mm dia barbs at 75mm spacing and straining andfixing to any type of type of standard rails complete all as specified and directed. |
| 57 | M &L for PVC concealed conduit point wiring with 1.5 square mm nominal area stranded copper conductor PVC insulated single core cable1100 Volts gradeconforming to IS694 part-i drawin20 mm size PVC conduit in concealed including 1100 volts grade 1.5square mm copper stranded single core cable green color PVC insulatedforcontineuous earthing wire with complete chesscutting ,S/F of 20 mm dia PVC conduit with elbow,bends,couplers,tee, sucken boxes pressed steel box mounting fitting/junction boxes etc covered the conduit with cement mortor after drawing of electric cables and making good of distrubed surfaces and match with existing shade of wall/roof for one light point controlled by one switch complete all as specified and directed. |
| 58 | Supply and fix in repair modular switch 1 way 6A, 1 module complete all as specified and directed.Make- Legrand/ Crab tree / Philips. |
| 59 | S & F in repair White cover plate with frame, 3 module including metal flush box 3 module complete all as specified and directed. |
| 60 | S & F in repair for ceiling rose 3 phase/PVC/polycarbonated isolated body complete all as specified and directed. |
| 61 | Supply and fixing in repair LED lights fitting 1x 18W, 220V,AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete.Make : Havells/ Bajaj/ Phillips/ Wipro |
| 62 | Supply and fix in repair building security light of35/36 watt IP 65 watt,LED die casting aluminium with LED street optic lenses, efficacy of skyline plus is upto 120lm/w, with pea nut lenses LED type with bracket arrangement all as per required and directed by Engg in Chrge.Make - Wipro Cat No LR13-241-XXX-57-XX or equivalent in Philips/Oshram |
| 63 | S & F in repair for MCB DB\"s 4 Way SPN, 240 volts for mounting MCBs/RCBO\"s ELCB\"s etc. as per IS specification of factory made fabricated out of CRCA sheet 1.2 mm thick powder coated fitted with DIN Channel neutral link and 200 Amps rated bus bar.The DB\"s shall double door type . Inner door fixed on spring loaded hinges with locking arrangement & outer door openable hinged with locking arrangement having IP-43 protection. |
| 64 | S & F in repair for MCB SPN 32 Amps 240 Volts C Curve 10 KA complete all as specified and directed. |
| 65 | S & F in repair for MCB SP 6-32 Amps 240 Volts C Curve 10 KA complete all as specified and directed. |
| 66 | Earthing complete with galvanised steel earth plate electrode of size 60cm X 60cm X 6mm buried directly in ground (earth pit not less than 2.25 metres deep below the normal ground level) with top edge of the plate not less than 1.5m below normal GL connected to GI earth wire 4 mm dia by means of GI bolts, nuts, check nuts and washers and earth strip protected by 25 mm dia GI pipe medium grade and connected to main distribution board/earthing test point all as shown on electrical plate No.3 of SSR Part I and all as specified including testing on completion.Notes: The unit rate shall also include for excavation, earth work in hard/dense soil, plain cement concrete 1:3:6 mix, Type C1 pit, 40mm thick RCC 1:2:4 mix, type B1 cover reinforced with 8mm dia TMT bars @ 150mm C/C both ways, GI funnel with watering pipe, wire mesh, protection pipe for earth lead upto 7.50m long complete in addition to item No. 1(a) to (e) of preamble (Notes) under sub heading earthing, specified in SSR Part II and also refer Plate No-03.Earth strip and protection pipe beyond 7.5m shall be measured and paid separately. Note :- Earthing will be redone if desired earth result not found during testing of the same at site. |
| 67 | S&F air termination, single pointed aluminium rod 12mm dia & 300mm long complete all as specified and directed. |
| 68 | S&F Aluminium strip 25 x 3.15mm with FRP saddles and fixing screws etc. for roof conductors and down conductors above ground complete all as specified and directed. |
| 69 | S&F test point terminal block made of gun metal or phosphorous bronze size 75 x 75 x 25mm drilled and screwed including 3 Nos, 8mm dia 25 mm long hex, Headscrew complete all as specified and directed. |
| 70 | Earthing complete with galvanised steel earth plate electrode 60×60cm× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less\"than 1.5 metres below normal ground level, using galvanised iron strip 32×6mm as earthing lead by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 5 connected to earthing test point all as specified or indicated including testing on completion (For lightning conductor) complete all as specified and directed. |
| 71 | Supply, laying and connecting XLPE insulated armoured heavy duty electric cable 16 sqmm 2 core with aluminum conductor 1100 volts grade cross sectional area laid in ducts/wall/cable tray/trenches with suitable size of cable glands, crimping type cable lugs, connecting to existing MCCBs in panels all as specified. |
| 72 | Supply and spreading clean and dry fine sand free from sharp material (unwashed) laying in trenches 8 cm thick before laying and 15mm thick after laying around the cable for cushioning teting, all as specified and directed by engg in charge. |
| 73 | Supplying and laying un-reinforced precast concrete cable cover, class LV,type 1 with peak, size 250mm x 150mm x 40mm complete , all as specified and directed by engr-in-charge. |
| 74 | Supply and fix light grade galvanisediron tube 40 mm bore with all fittings and fixed to walls / ceiling or laid in floor, pole or laid in trenches and road crossings including sealing ends with hession cloth impregnated with bituminous compound in ground and with teak wood bushes for ends fixed with walls / poles complete all as specified and as directed. |
| 75 | M & L for Iron free standing unit theft proof Rifle Rakes complete as per sample. |
| 76 | Total contract sum shall be calculated after deduction of schedule of credit amount of Rs. 1,370.00 |