Sales : +91-777 804 8217
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 13-02-2026 | Tender Corrigendum | Other | 28-02-2026 |
| 2 | 13-02-2026 | BOQ Corrigendum | BOQ | 28-02-2026 |
| Sl. No. | Item Description |
| 1 | Demolition of existing old tarfelt, water proofing membrane including roof tiles, cement mortar screed, concrete base of any thickness and roughing surfaces to receive roof treatement including removal of debris from MoD land, complete all as specified and as directed. |
| 2 | 15mm thick plaster on roof / concrete surfaces incl parapet etc in cement mortar 1:3 and finished even and smooth without using extra cementand mixed with waterproofing compound as per manufacturers instructions. (Note. WPC shall be measured and paid separately). |
| 3 | Supply only liquid water proofing compound conforming to IS 2645-1975 of approved make complete all as specified and directed.(Dosage- @ 200ml per 50Kgs of Bags of cement) |
| 4 | Water proofing treatment to RCC roof slab including parapet as under :- (a) Ist Course: Apply a coat of bituminous primer conforming to IS-3384@ 0.40 Kg /Sqm on prepared surface of plaster and after drying of primer, apply a coat of hot blown 85/25 grade bitumen conforming to IS-702 @ 1.2 Kg/sqm on plastered surfaces. (b) 2nd Course :APP (Atactic Polypropylene) modified polymeric membrane, 5 layered,3 mm thick weight not less than 3.0 Kg/Sqm with 160 Grams/Sqm non woven polyester made at centre core reinforced laid with 75 mm side overlap and 150 mm end overlap, membrane has to be laid with LPG torch and overlap sealed and finished neat, all joints.(c) 3rd Course : Apply a coat of hot blown 85/25 grade bitumen conforming to IS-702 @ 1.2 Kg/sqm over membrane and dusted with dry sand @ 0.50 to 1 Kg/sqm. (i) On Non-accesible roof : After providing (a) to (c) provide aluminium paint as per manufacturer instructions.(ii) Coved fillet in PCC 1:2:4 type B0 (using 12.5 mm graded crushed stone aggregate) of required radius 75mm shall be provided at the junction of roof and vertical surface such as parapet wall/mumty around opening and treatment mentioned above shall be applied followed by a cement plaster 20mm thick in cement mortar(1:6).Note :(i) Roof treatment work shall be carried out through approved manufacturers only or through their authorised personal only. |
| 5 | PCC 1:2:4 type B-1 (using 20 mm graded crushed stone aggregate) as inroof padding in roof slab for levelling course complete all as specified and directed. |
| 6 | Dismantling structural steel work including doors, gates but excluding framed truss etc. complete all as specified and directed. |
| 7 | Dismantling asbestos cement (corrugated, semi corrugated) sheets including ridges as in roof covering, complete all as specified and as directed. |
| 8 | Dismantling wall and ceiling boards, fibre pulp insulation etc or insulation boards/ slabs / blankets, any thickness, including cover fillets, complete all as specified and directed. |
| 9 | Structural steel work as in roof trusses (framed), trussed purlins, crane gantries, rails and fastening and heavy brackets (Beam, tee, angle, channel or hollow steel section) including distance pieces, cleats etc confirming to Fe-410-W (Gde-E-250) quality A complete all as specified and directed. |
| 10 | Framed mild steel work such as grills, gratings etc., with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe 410W Gde-E-250 complete all as specified and directed. |
| 11 | Pre- painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws, complete all as specified and as directed. |
| 12 | Pre- painted galvalume aluminium zinc coating GI based plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws, complete all as specified and as directed. |
| 13 | 4mm thickPre-laminated designer false ceiling board over GI snap grid frame work (Grid size 600x600mm) with powder coated GI angle of size 25x25x3mm, main runner \"T\"of size 25x40x3mm , secondary runner \"T\" of size 25x30x3mm suspended with 3mm GI wire @ 1200mm c/ccomplete all as specified and directed. |
| 14 | Demolition of brickwork or stone boulder masonarybuilt in cement mortar including all quoins, arches, pillars etc complete all as specified and as directed. |
| 15 | Brickwork with sub class ‘B’ (old size) bricks, straight or curved on plan exceeding 6 metre mean radius built in cementsand mortar 1:6 complete all as specified and as directed. |
| 16 | Brick work with sub class B brick straight or curved on plan to any radius in half brick thick built in CM 1:4 complete all as specified and directed. |
| 17 | Taking down cement plaster from brick or stone walls incl racking out joints hacking for key, scrubbing down with water etc all as specified and directed. |
| 18 | Dismantling floor, hearth or wall tiling incl cement mortar bedding (but not backing) removing serviceable tiles to store and rubbish off the premises,complete all as specified and directed. |
| 19 | Rendering 5mm thick cement plaster with cement mortar(1:3) on concrete surface as in ceiling finished the surface even and smooth without using extra cement, complete all as specified and directed. |
| 20 | 15mm thick cement plaster rendering in CM 1:4 on fair faces of bricks or concrete surfaces including mixing of WPC as per manufacturer\"s instruction & finishing the surface even and smooth without using extra cement complete all as specified., complete all as specified.Note :- WPC Shall be measured and paid separately. |
| 21 | Rendering 15 mm thick cement plaster with cement mortar(1:6)on other than fair faces of brick work or concrete surfaces and finished even and smooth without using extra cement, complete all as specified and directed. |
| 22 | Preparation of newly plastered surfaces of walls andapplying two coats of oil bound distemper over a coat of chalk whitening primer complete all as specified and as directed. |
| 23 | Complete removal of existing treatment of old surface of wall incl making good the surface with putty complete all as specified and directed. |
| 24 | Preparation of newly plastered surfaces of ceiling and applying three coats of white wash, complete all as specified and directed. |
| 25 | Preparation on new plastered surfaces of walls and applying two coat of oil bound distemper over a coat of 2 mm thick wall putty after complete removal of existing surfaceof any layer complete all as specifieed and as directed. |
| 26 | Preparation of old plastered surfaces of ceiling and applying two coats of white wash complete all as specified and directed. |
| 27 | Preparation of plastered or unplastered old surfaces of walls including complete removal of existing treatment and applying two coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance,dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm on wall surface, complete all as specified and directed. |
| 28 | Preparation of new plastered surfaces of walls and applying two coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance,dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm on wall surface, complete all as specified and directed. |
| 29 | Demolition of cement concrete(unreinforced) in ground floor and in paving not exceeding 15 cm thickness (below or aboveground level) complete all as specified and as directed. |
| 30 | Demolition of stone slaband tiles of any description or thickness laid bedded and pointed in any mortar in floors, aprons etc. complete all as specified and directed |
| 31 | 20-25 mm thick machine cut kota stone slab as in flooring, laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing laid over with mirror cut polishing 100mm wide marble patti/border all around and including 15mm thick screed bed in cement and sand mortar 1:4 complete all as specified and as directed.Note:-(Size of Kota Stone slab shall be 53 cm x 53 cm). |
| 32 | Description all as per item No 31 above but in skirting/dado incl 10mm thick rendering CM 1:4 complete all as specified and directed. |
| 33 | Non skid ceramic coloured tiles 7 to 8 mm thick (square / rectangular), area of each tile exceeding 0.11 Sqm but not exceeding 0.18 sqm, as in floors, set and jointed in neat cement slurry and pointed in colouredcement laid over & including 15mm thickscreed bed or bedding layer in cement mortar 1:6,complete all as specified and directed. |
| 34 | Vitrified ceramic coloured tiles (light shade) 10 mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to matchthe shade of tiles with & including 15 mm thick screed bed in cement and sand mortar 1:6,complete all as specified and directed. |
| 35 | Glazed ceramic coloured tiles 450x300x7mm thick on vertical surfaces such as skirting, dados and risers to steps etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match over & including 15mm thick rendering in CM 1:4 finished even and fair to receive tiles, complete all as specified and directed. |
| 36 | Granite flooring (of any type) 20mm thick machine cut, bedded and jointed with grey cement slurry and jointed with white cement with admixture of pigment to match the shade of granite stone including cutting, moulding & polishing laid over & including 15mm thick screed bed in CM 1:4, complete all as specified and directed. |
| 37 | Providing cement concrete type B-1, 1:2:4 ( using 20mm graded crushed stone aggregate), 50 mm thickas in plinth protection laid in alternate bays not exceeding 2 Sqm each and finishing even and fair ontop without using extra cement with 6mm wide joints throughout the thickness of plinth protection in concrete bays and in between the walling and plinth protection, filling the joints with mastic filling comprising of one part of heated bitumen 85/25 or 95/10 grade and 3 parts of sand ( all by weight), complete all as specified an directed. |
| 38 | 40 mm thick PCC 1:2:4 type B-0, (using 12.5 mm graded crushed stone aggregate), as in floor finished even and fair complete all as specified and directed. |
| 39 | Repair to balcony/Facia/Roof projections and soffit of chajjas etc by taking down old rendering and hacking clearly the edges and corners smooth rounded for new plastered area exceeding 30sqm in width or girth & providing 15 to 20mm thick plastering to match with the existing thickness in CM 1:4andincluding formwork up to height 7.0 mtr above ground level of bldg including two coats of Apex/cement based paint over one coat of primer complete all as specified. |
| 40 | Taking down chowkhats or frameswith shutters (without taking off shutters from the frames) of size n. exc 1.5 Sqm each complete all as specified and as directed. |
| 41 | Taking down chowkhat or frames of door/ window with shutters (Without taking off shutter from the frame) exc 1.50 m and n.exc 4.00 Sqm each complete all as specified and as directed. |
| 42 | Mild steel framed workas in door or gate of angle or other section with gusset plate, rail braces, hold fast, guard bars clamps etc Fe 410-W (Gde E-250) A quality including one coat of primer complete all as specified and directed. |
| 43 | Pressed steel frames of sizes 105 x 60 mm for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plates complete including one shop coat of red oxide primer, providing mild steel 6 mm dia threshold bar and filling hollow of frame,all as specified and directed. |
| 44 | Pressed steel frames of sizes 125 x 60 mm for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plates complete including one shop coat of red oxide primer, providing mild steel 6 mm dia threshold bar and filling hollow of frame,all as specified and directed. |
| 45 | PCC 1:2:4 type B-0 (Using 12.5 mm graded crushed stone aggregate) as in back filling of pressed steel frame or in parapet coping complete all as specified and directed. |
| 46 | PCC 1:3:6 type C-1 (Using 20mm graded crushed stone aggregate) for hold fast blocks, including necessary form work for rough finished surfaces etccomplete all as specified and as directed. |
| 47 | Solid PVC Door frame of size 50 mm x 47 mm made out of 5 mm plain colour PVC sheet reinforced with M.S square tube, supplying and fixing in opening as per specification and drawing, complete all as specified and directed. |
| 48 | Factory made solid panel PVC door shutter 30mm thick style consisting of frame made out of MS tubes for top & bottom rails MS frame shall be covered with heat moulded plain colour PVC \"C\" channel having a PVC sheet strip of 20mm width struck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail and bottom rail on either side and as gap insert for top rail and bottom rail, panelling of plain colour PVC sheet to be fitted in the MS frame welded/sealed to the styles & rails with suitable PVC sheet beading andjointed together with solvent cement supply & fixing in the frame at site, complete all as specified and as directed. |
| 49 | 35mm thick, 2nd class hard wood plain framed, panelled (factory made) shutters (two panels) with lock rail and panel of 9mm BWP commercial ply or 12mm veneered particle board with commercial veneering on both faces. The size of rail and stile as per IS-1003 (Part-I) (Larger size to be provided) kiln seasoned and chemically pressure treated, complete all as specified and directed. |
| 50 | 35mm thick 2nd class soft wood Glazed and skelton shutters, open rebated and prepared to receive glass, gauge etc devided into square with sash bars, edges of framing plain, chamfered or rounded fitted with cut and mitered beads for securing glass etc. size of members of shutters as specified in SSR Part-I, Section 8, clause 8.24 (a) supplied and fitted to chowkats complete all as specified and directed. |
| 51 | Prelaminated particle board 12mm thick, interior grade, prelaminated one side with decorative choice lamination & other side balancing white lamination, fixed to mild steel work with screws complete all as specified and directed. |
| 52 | Prelaminated particle board 18/19mm thick, interior grade, prelaminated one side with decorative choice lamination & other side balancing white lamination, fixed to frame work with screws complete all as specified and directed. |
| 53 | External teak wood lipping 6 mm thick fixed with nails for 18/19 mm thick board, complete all as specified. |
| 54 | 3mm thick sheet glass ordinary quality and glazing with oil putty in squares n.exc 0.5 Sqm in each pane complete all as specified and directed. |
| 55 | 4mm thick figured glass, pin head type and glazing with oil putty in squares n exc 0.5 sqm in each pane complete all as specified and directed. |
| 56 | Galvanised mild steel wire cloth, 0.56 mm nominal dia of wire and average width of aperture 1.18 mm and fixed with tinned tacks or galvanised wire staple complete all as specified and directed. |
| 57 | 100 mmbutt hinges, medium weight cold rolled mild steel, complete all asspecified. |
| 58 | Butt hinges of size 75 mm medium weight for rolled fixed as in cupboardwelded with angle iron frame complete all as specified and directed. |
| 59 | Aluminium anodised barrel tower bolt 150mm extruded section ISI marked complete all as speicified. |
| 60 | Aluminium handles cast type anodised of size 100mm long ISI marked complete all as specified and as directed. |
| 61 | Aluminiumanodised sliding door bolts with hasp and stapple extruded sectionor cast aluminium alloy with length of bolt as 300 mm including fixing bolts complete all as specified and directed. |
| 62 | Mild steel springs for doors, 300 mm, ordinary rat tail rod pattern including roller and roller plate complete all as specified. |
| 63 | Floor door stopper 100mm overall length of cover plate of aluminium alloy body and tongue,anodised,with hard drawn steel spring,fixed in bottom body of door complete all as specified and as directed. |
| 64 | Curtain rail ,20 mm dia anodised aluminium alloy chromium platedfixed with braket, incl taking down of old curtain rods, complete all as directed. |
| 65 | Steel windows/ventilator (Box type) factory made glass/glazed shutter, (glass panes window shall be measured and paid separately) of size 79mmx39mm,16 gauge rectangular tubular frame withside hung shutter with glazing bars 12x3mm flat iron incl box type hinges with steel handle and steel peg stay dovetailed or welded incl 2 Nos tower bolts 100mm long including 08 mm square bar grills complete all as specified & as shown on drg No. CEUZ/TD/1302/2009 Sh no 1/1 to 1/3 . |
| 66 | Ditto all as per item No 65 above here-in-before but without grill and glazing bar complete as specified and directed. |
| 67 | Preparation of new or untreated steel of any description, not otherwise described over 10cm width or girth and applying two coats of synthetic enamel paint over one coat of red oxide zinc chrome primer, complete all as specified and as directed. |
| 68 | Preparation of newor untreated wooden of any description, not otherwise described over 10cm width or girth and applying two coats of synthetic enamel paint over one coat of primer, complete all as specified and as directed. |
| 69 | Vitreous china squatting pan \"Orissa Pattern\" size 580 x 440 mmin any colour with integral foot rest incl lime mortor, \"S\" trap including connection to trap, and to flushing pipe, anti-syphonage pipe etc complete including making good to floor and complete taking down old one as in repairs complete all as specified and directed. |
| 70 | PVC valve less, Symphonic action type, flushing cistern of capacity 10 liters, low level, white with inlet, ball valve, manually operated with one PVC ball valve horizontal plunger type including provision of 32mm PVC flush pipe of required length and making connections complete, fixed in repairs complete all as specified and as directed. |
| 71 | Vitreous china wash basin of size 550x400mm including waste fittings chromium plated brass CP steel chain and rubber plug, procelain stopper and pair of CI brackets, waste pipe fixed in repairs complete all as specified and directed. |
| 72 | Pillar taps 15mm cast copper alloy CP, fancy type with capstan head, screwed down high pressure with or without lettered ‘Hot’ or ‘Cold’ with long screwed shanks and fly nut, screwed for iron pipe15 mm bore.fixed in repairs,complete all as specified and as directed. |
| 73 | PVC connection 15 mm size, of length 600 mm, with PTMT nuts & repairs fixed in repairs, complete all as specified and as directed. |
| 74 | CP angle valve stop cock (weight not less than 0.40Kg as mentioned in SSR part- 1 clause no. 18.14.2)of cast copper alloy (ISI Marked) chromium plated fancy type screwed down high pressure with capstain head screwed both ends for iron pipe 15mm bore fixed in repairs complete all as specified and directed. |
| 75 | Bib tap 15 mm bore with flange, Brass CP, fancy type(long body). with crutch or butterfly handle screwed down screwed for iron pipe or for brass ferrule and fixed in repairs, complete all as specified and as directed. |
| 76 | CP brass wall mixture for mixing hot and cold supply screwed down incl connecting legs and wall flanges for iron pipe of 15mm bore fancy type fixed in repairs complete all as specified and directed. |
| 77 | Corner glass shelf assembly consisting of 5.5 mm thick sheet glass shelf with chromium plated bracket guard as in repairs complete all as specified and directed. |
| 78 | Chromium plated brass towel rail 20 mm dia D-type 60 cm long between flanges, including brackets and fixed to walls as in repairs complete all as specified and as directed. |
| 79 | Brass chromium plated shower roses 125mm with or without swivel joints, including fixing to steel pipe or union fixed in repairs all as specified and directed. |
| 80 | Plate rack made of stainless steel 0.8mm thick overall size 786mm x 610mm x 254mm fixed in repairs complete all as specified and directed. |
| 81 | Stainless steel sink with drainage board made of stainless steel 1mm thick kitchen or laboratory with plugs, washers and wastes; including bedding in cement mortar to dwarf wall or including fixing cantilever brackets and connecting union to pipe overall size 915mm x 460mm bowl size 410mm x 330mm x 160mm fixed in repairs, complete all as specified. |
| 82 | Taking up or down steel tubing and connection and removing to store bore of pipe 15mm dia complete all as specified and directed. |
| 83 | Ditto all as per item No 82 here-in-before but bore of pipe 20mm dia. |
| 84 | GI tubing of 15mm (Medium grade) with all fittings and fixed complete to walls and ceilings and floor/roof complete all as specified and directed. |
| 85 | GI tubing of 20mm (Medium grade) with all fittings and fixed complete to walls and ceilings and floor/roof complete all as specified and directed. |
| 86 | Dismantling water tanks and removing to storeof cap exc 250 but n.exc 500 ltr all as specified and directed. |
| 87 | Rotational moulded polyethylene 03 layer water storage tanks of 500 Litres capacity, (cylindrical vertical tanks with closed top) hoisted and fixed in position including making necessary arrangements for fixing inlet, outlet and over flow pipe and provision of wash out pipe etc complete all as specified and as directed. |
| 88 | Ball valves, high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball, screwed for iron pipe20 mm dia (minimum weight 210 gms) complete all as specified and directed. |
| 89 | 20 mm dia bore gun metal globe or gate valve with iron wheel head screwed both end for iron pipe fixed in repairscomplete all as specified and directed. |
| 90 | Taking down eaves gutters and rain water pipe , soil and waste pipe (any size or pattern ), including all fittings, heads , shoes bends , swan-necks etc. complete all as specified and as directed. |
| 91 | PVC (SWR) pipes 110mm bore single socketed in any length with rubber ring joints fixed to wall weight of pipe not less than 0.70Kg/RM complete all as specified and directed. |
| 92 | PVC (SWR) pipes 75mm bore single socketed in any length with rubber ring joints fixed to wall weight of pipe not less than 0.70Kg/RM complete all as specified and directed. |
| 93 | PVC (SWR) branch bends any radius 110mm bore of pipe complete all as specified and directed. |
| 94 | PVC (SWR)junction single (single T) equal or unequal provided with access door 110 mm diaall as specified and directed |
| 95 | PVC (SWR) branch bends any radius 75mm bore of pipe complete all as specified and directed. |
| 96 | PVC junction (Single T) equal or unequal ordinary or inverted with spigot or socket branch of 75mm bore complete all as specified and directed. |
| 97 | PVC (SWR) branch piece 75mm (single Y) equal or unequal inverted in spigot or socket type all as specified and directed. |
| 98 | PVC SWR vent cowl75 mmcomplete all as specified and as directed. |
| 99 | PVC (SWR)75 mm dia floor trap plain with grating including jointing with solvent cement fixed in repairs, all as specified and directed |
| 100 | Plain cement concrete type B-0 1:2:4 (12.5mm graded crushed stone aggregate) as in roof kerbs or mud stops, in floors, plinth courses, rounded or chamfered on edges complete all as specified and as directed. |
| 101 | Aluminium anodised hasp and staple safety type 75mm long with mild steel hinges pin including bolts to hinge plate and fixed with screws complete all as specified and directed. |
| 102 | 100mm thick Plain Cement Concrete as in sub base type E2 (1:5:10) using 40mm graded crushed stone aggregate complete all as specified and directed. |
| 103 | Sand cushion in flooring below interlocking tiles each layer 25mm thick complete all as specified and directed. |
| 104 | Machine pressed precast concrete interlocking paver block of any shape and size confirming to IS-15658-2006 of 60mm thickness M-40 grade, laid jointed & pointed with grey cement and pigments,packing the joints of paver block including watering and consolidation all as specified and directed. |
| 105 | Coloured chequerd tiles 25cm x 25cm x 22-25mm/300x300x22-25mm thick as in path set and jointed and pointed in neat cement slurry and pointed in white or coloured cement and pigment as in flooring including 15mm thick rendering as in CM 1:4 complete all as specifed and directed. |
| 106 | Demolition and breaking up drain pipes (Salt glazed ware, AC or Reinforced concrete) set in cement mortarof 150 mm diameter incl bends, complete all as specified and directed. |
| 107 | Demolition of reinforced cement concrete of any description and in any position including cutting reinforcement as required to facilitate complete all as specified and directed. |
| 108 | Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out etc in any type of soil, complete all as specified and directed. |
| 109 | PCC 1:3:6 type C-2 (using 40mm graded crushed stone aggregate) as in foundation filling and mass concrete all as specified and directed. |
| 110 | PCC 1:2:4 type B-0 (Using 12.5mm graded crushed stone aggregates) as in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, water troughs and the like including weathering, slightly rounded or chamfered angles including necessary form work complete all as specified and directed. |
| 111 | Concrete bed to drain pipes in PCC 1:3:6 type C-2 (Using 40mm graded crushed stone aggregate) including packing under and haunching against the side of pipes after they are laid and tested for 150mm internal dia of pipe including necessary formwork, complete all as specified and directed. |
| 112 | RCC classNP3 150mm dia drain pipes laid in trenches and jointed with & including coller ISI mark complete all as specified and directed. |
| 113 | Reinforced cement concrete 1:2:4, B-1 (Using 20mm graded stone agg) as in manhole covers slab/shelves etcincluding necessary form work for fair finished surfaces complete all as specified and directed. |
| 114 | TMT Bar 8mm dia bar and over cut to length, bent to shape required including cranking, bending, hooking ends, binding, with and including mild steel wire (annealed) not less than steel wire 0.9mm dia or securing with clips, complete all as specified and directed. |
| 115 | Returning filling in including spreadingwateringand well ramming in layers not exc25cmcomplete all as specifed and directed. |
| 116 | Removing excavated material n.exc 50 mtr and depositing where directed at a level n.exc 1.5 mtr above the starting point, complete all as specified and directed. |
| 117 | Preparation of surfaces of walls finished with putty and applying two coat of oil bound distemper over one coat of primer all as speicfied and directed. |
| 118 | Vitrified ceramic coloured tiles (light shade) 10 mm thick (square/ rectangular) polished, area of each tiles exceeding 0.18 sqm but not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to matchthe shade of tiles with & including 15 mm thick screed bed in cement and sand mortar 1:4,complete all as specified and directed. |
| 119 | Ditto all item no 118 above here-in-above but as in vertical surfaces dado/skirting over a backing coat of CM 1:4, 10mm thick complete all as specified and directed. |
| 120 | Powder coated aluminium (min thickness of powder coating 50 micron) work for door windows, ventilators and partitions (fixed portions) with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285 fixing with dash fasteners of required dia and size including necessary filling up the gaps at junctions i.e. at top, bottom and sides with required EPDM rubber/neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, aluminium snap beading for glazing/paneling, CP brass/stainless steel screws all complete as per architectural drawings complete all as specified and directed. |
| 121 | 5.5mm thick sheet glass ordinary quality and glazing with oil putty in squares n.exc 0.5 Sqm in each pane fixed with aluminium frame as in partion/door frame complete all as specified and directed. |
| 122 | Steel windows/ventilator (Box type) factory made with double shutter with or without dovetailed bar ( glass & glazed shutter) of size 79mmx39mm,16 gauge rectangular tubular frame withside hung shutter with glazing bars 12x3mm flat iron incl box type hinges with steel handle and steel peg stay dovetailed or welded incl 2 Nos tower bolts in each shutter 100mm long with & including 8mm square bar grills, complete all as specified & as shown on drg No. CEUZ/TD/1269/2008 Sh No 1/1 to 1/3 .Note:-(a) Fixed type glass panes shutter if any provided in above same window shall be measured and paid separately & area of these fixed shutter shall be deducted from total area of box type window for payment purpose. (b) Sheet glass/ wire cloth shall be measured & paid separately under respective item |
| 123 | Factory made box type steel ventilators top hung shutter glass/glazed including guard bars ,hinges,steel handle,tower bolt and steel peg stay,complete with or without glazing bars ,dovetailed or welded, including one coat of red oxide primer complete shown as drawing No (CEUZ/TD/1517/15 Sh No 1/3 to 3/3) |
| 124 | Taking down carefully copper/aluminium point wiring (light,fan,bell, socket or power)complete,including fixtures and fittings such as switches, ceiling roses, holders,regulators, sockets, tube light fittings and including making good the disturbed surfaces to match with existing surface and colour shade with putty and white cement at necessary holes for smooth finishing complete all as specified and directed complete all as specified anddirected. |
| 125 | Point wiring complete with 1.5 sqmm PVC insulated, FRLSHtype, ISI marked,conforming to IS-694/1990 unsheathed,multistranded,single core, copperconductor cable 1100 volts grade colour code cablesdrawn through and including PVCConduit 20 mm dia medium grade andincluding cutting, chasing work at any height and all accessories are concealedinwalls / roofs / floors / ceiling etc. metal flush boxwith top,bottom,side/back wall knockout for conduitentry from any direction made out of 1.60mm thick suitable for fixing ofmodular top cover plate as per numbers of switch modules for modular switches,sockets,fan regulators,red colour indicator, blank plates etc as approved coloursandincluding 1.5 Sqmm PVC insulated multistranded FRLSHtype unsheathed(Green colour),single core cable with copper conductor cable as earth continuity conductor andconnecting to common earth dolly and including making good the disturbed surfaces to match with existing surface and colour coat including providingputty and white cementfor smooth finishing of existing surfacecomplete all as specified and directedfor theOne light point/fan /bell pointcontrolled by one switch.(Note:- Allnecessary accessories such asmodular steelbox,top cover plate, blank plate, screws,washers are to be used of same make/brand onlyand shall be deemed in to included in quoted rate only.) |
| 126 | One light point/fan /bell pointcontrolled by one switch. |
| 127 | One 3 pin 5 amps socket point controlled by one 5 amps switch on independent board . |
| 128 | One 3 pin 5 amps socket point controlled by one 5 amps switch on same board . |
| 129 | All as per item No 125 above but point wiring with 2.5 sqmm and earth conductor of size 2.5 sqmm complete all as specified and directed for the following:- |
| 130 | One 6 Pin 16/6 amps socket outlet point controlled by one 16 amps switch on independent board. |
| 131 | Modular type switch 10 Amps, single pole,1way,1/2 module,240V, ISI Markedcomplete all as specified and directed. |
| 132 | Modular type switch 16 Amps, single pole, 1way,1/2 module, 240V, ISI Marked Complete all as specified and directed. |
| 133 | Modular type socket shuttered type 6 Amps 2/3 pin combined 2 module 240V AC ISI marked complete all as specified and directed. |
| 134 | Modular type socket shuttered type 16 Amps 2/3 pin combined 2 module 240V AC ISI marked complete all as specified and directed. |
| 135 | Angle lamp holder, insulated body with back plate for LED lamp including removing old unsv itemcomplete all asspecified and directed. |
| 136 | Ceiling rose, 3 terminal ,PVC/polycarbonate body ISI marked, complete all as specified and directed |
| 137 | LED light fitting General purpose surface and wall mounted LED batten with Aluminium housing integrated electronic driver, 20W, 4 feet and connecting up with twin core twisted copper wire from LED fitting to ceiling roseand removing old unserviceable fitting complete all as specified and directed. |
| 138 | LED light fitting General purpose surface and wall mounted LED batten with Aluminium housing integrated electronic driver, 10W, 4 feet and connecting up with twin core twisted copper wire from LED fitting to ceiling roseand removing old unserviceable fitting complete all as specified and directed. |
| 139 | LED INVERTER batten 20 w 4 feet with square profile and poly carbonate channel lithium ion battery with charging time 8 to 10 hours and backup time upto 4 hoursand connecting up with twin core twisted copper wire from LED fitting to ceiling roseand removing old unserviceable fitting complete all as specified and directed. |
| 140 | LED bulb 12 watts, 240Volts,50Hzpin type andincluding removing old unserviceable itemcomplete all as specified and directed. |
| 141 | LED secruity light fitting of capacity35 Watt LED street light fitting in aluminium PDC housing, toughened glass cover with IP65 protectionwith suitable inbuilt surge protector and cable connection from ceiling rose to light fitting and testing and including removing of old unserviceable item complete all as specified and directed. |
| 142 | Supply & fixing and in repair sheet metal enclosure acrylic door 240 volts AC,SPNdistribution board 8 way suitable for flush mounting with 100amps copper busbar,neutral bar,earth barand MCB incomer of rating upto 100Amps ,MCB SPN/DP,and MCB SP as outgoing and complete connecting cable linkswith top and bottom removable gland plate with IP 43 DBs protection and including making good the disturbed surfaces to match with existing surface and colour coat all as specified and as directed. |
| 143 | MCB SP 6 to 32 Amps 10 KA,\"C\" series,AC,240Volts,50Hz , ISI marked fixed in repairs complete all as specified and directed. |
| 144 | MCB single pole & neutral 40 to 63 amps 240 volts 10 KA \"C\" series fixed in repair, complete all as specified and directed. |
| 145 | Earthing complete with galvanised steel earth plate electrode 600mmX 600mmX 6mm thick buried directly in ground vertically ( earth pit not less than 2.25 meters deep below ground level) with top edge of plate not less than 1.5 metres belowground level, connected to and including galvanised iron wire 4 mm dia and light grade protection pipeof 15 mm diafrom earth electrode up to test point or up to 7.5mtr whichever is less by means of GIbolts, nuts, check nuts and washersall as per electrical plate No 3 of SSR Pt-I and GI watering pipe of 20 mm dia medium grade,GI funnel with wire mesh,including charcoal, salt packed all around the earth electrode plate in layers, PCC earth pit chamber 1:3:6 type C1, of size 45X 45X 45 CM,RCC cover 1:2:4 type B1 of size 45X45X6CM with Reinforcement bars of 8mm dia @120mm c/c excavation/earth work in any strata and returning filling, removal of surplus soil and testing/test point for required valueincluding removing old item completeall as specified and directed. |
| 146 | Exhaust fansingle phase metal body, AC 230 Volt, 50 Hz, 900 RPMof size 300mm sweep with louvers shutter complete with all accessories including connecting up from ceiling rose and taking down old existing one depositing the same in the MES store yard complete all as specified and directed. |
| 147 | Sub main wiring complete with 2 runs of 6 sqmm single core copper conductor (ISI marked)cable1100 volts grade,FRLSH type, PVC insulated, unsheathed, flexible, multi strandedcolour coded cables drawn throughrigid PVC conduit of size 25 mm dia medium grade(MMS) with all connected accessories such asBend,Tee,Elbow,Short peices etc concealed in wall/roofs/floorsand including one run of 2.5 sqmm single core copper conductor cable flexible, PVC insulated, unsheathed, multistranded, 1100 volts grade,FRLSHtype as earth continuity conductor connected to common earth dollyincluding making good the disturbed surfaces to match with existing surface including taking down of old existing submain cable complete all as specified and directed. Note : - Two run of 6 sqmm single core copper conductor cable and one run of 2.5 sqmm single core copper conductor cable as earth continuity and one run of PVC conduit shall be measured as one unit. |
| 148 | Ceiling fans complete with blades. Down rods, electronic regulator and accessories, 230 volt, 1200mm sweep, min air delievery 210 CFM with service value 6 BEE five star rated with brushless direct current motor (BLDC) incl taking down existing and deposit with MES store yard all as specified and directed. |
| 149 | Ceiling fans complete with blades. Down rods, electronic regulator and accessories, 230 volt, 1400mm sweep, min air delievery 245 CFM with service value 6 BEE five star rated with brushless direct current motor (BLDC) incl taking down existing and deposit with MES store yard all as specified and directed. |
| 150 | Vertical double door TPNin replacementare fitted with Bus bar neutral link, blanking plates of 4 way(4+12) with suitable for incomming MCCB 4 pole\"G\" frame,having isolated neutral bar, mechanical impact strength IK09, door earthing suitable for MCCB upto 125 Amp, complete all as specified and directed. |
| 151 | MCCB 04 pole 415 volts 16 KA, 63 Amp adjustable thermal & fixed magnetic setting type suitable for TPN vertical loadline DB mentioned at ser No 146 here in before fixed in replacement, complete all as specified and directed. |
| 152 | Supply and fixing in replacementelectric water heater, storage type steel body with copper inner tank and heating element upto 2 KW capacity 25 litre, BEE 5 Star rated complete with all accessories such as safety valve, thermostate, NRV, connection piece incl making holes on walls for proper fixing with nuts and bolts complete making the surface good as per existing all as specified and directed. |
| 153 | Exhaust fansingle phase metal body, AC 230 Volt, 50 Hz, 900 RPMof size 450mm sweep with louvers shutter complete with all accessories including connecting up from ceiling rose including taking down old existing one depositing the same in the MES store yard complete all as specified and directed. |
| 154 | Air circulator fans 230 volts single phase oscillating 450mm sweep suitable for wall mounting complete all as specified and directed. |
| 155 | Supply, laying, jointing and testing XLPE cable insulated, armoured, earthed, heavy duty electric cable with aluminium conductor, 1100 Volt grade, cross sectional area 50 sqmm 3.5 core including necessary cable lugs, glands, insulation tape etc complete all as specified and as directed. |
| 156 | Double wall corrugated (DWC) HDPE pipe of size 50mm including snap fit coupler conforming to IS16098, SN4 pressure rating for protection under ground cable complete all as specified and directed. |
| 157 | Calling bell, Ding dong AC 230 Volt single complete all as specified and directed. |
| 158 | Modular bell push 6A, 1 module 240 V ISI marked complete all as specified and directed. |
| 159 | Supply, laying, jointing and testing XLPE cable insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor of size 35 sqmm 3.5 core complete all as specified and directed. |
| 160 | Double wall corrugated (DWC) HDPE pipe with outer wall for being corrugated impacts, excellent ring stiffness (comparision strength) and inner wall for smooth allowing easy insertion of cable in orange colour with and external influence (IP-66/67) with governing specification IS 16205: Part 24:2017 of size 50mm/38 (outer dia/inner dia) for protection of cable in ducts/walls/pole etc complete all as specified and directed. |
| 161 | Galvanised pipe \"medium class\" including fittings 25mm (1.0) dia including all fitting and jointing with inserting of cutting of suitable size from existing pipeline complete all as specified and directed. |
| 162 | Preparation of old wood or wood basedsurfaces of any description not otherwise described over 10 cm in width or girth, and appying one coat of synthetic enamel paint complete all as specified and as directed. |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail