| 1 | Demolition of brick workbuilt in cement mortar complete all as specified and as directed |
| 2 | M&L brick work with sub class \"B\"brick straight or curved on plan exc 6m mean radiusbuilt cement mortar 1:4 complete all as specified and as directed |
| 3 | M&L for brick work with sub class ‘B’ bricks old size straight or curved on plan to any radius in half brick thick wall built in cement mortar (1 : 4) etccomplete all as specified and as directed. |
| 4 | Taking down cement plaster on brick or stone wall including raking out joints, hocking for key scrubbing down with water etc complete all as specified and as directed. |
| 5 | M&L for rendering 10mm thick on fair faces of wall even and smooth finish without using extra cement onconc/brick surfaces in CM 1:6, complete all as specified and as directed |
| 6 | M&L renderig 5mm thick in cement mortar 1:3 on ceiling surface and finished even and smooth with out using extra cment complete all as specified and as directed. |
| 7 | M&L for rendering 15mm thick on fair faces of wall even and smooth finish without using extra cement onconc/brick surfaces in CM 1:4, complete all as specified and as directed |
| 8 | M&L for complete removal of existing treatment of any description from wall complete all as specified and directed. |
| 9 | M&L for complete removal of existing treatment of any description from ceiling complete all as specified and directed. |
| 10 | M&L for applying 1 mm thick wall care putty on wall suface complete all as specified and as directed by the Engr-in-Charge. |
| 11 | M & L for preparation of old plastered surface of walls and applying two coat of oil bound distemper on wall surface as per manufacurers instructions etccomplete all as specified and as directed by the Engr-in-Charge. |
| 12 | M&L for applying two coat of white wash on wall suface complete all as specified and as directed. |
| 13 | M&L for applying two coat of white wash on ceiling surface complete all as specified and as directed. |
| 14 | Material & Labour for applying two coat of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over oldsurfacescomplete all as specified and as directed by Engr-in-Charge. |
| 15 | M&L for preparing for old steel surfaces and applying one coats of synthetic enamel paint over 10 cm width or girth complete all as specified and as directed. |
| 16 | M&L for preparation old wooden surface of any description not otherwise described over 10 cm width or girth and applying one coat synthetic enamel paintetc complete all as specified and as directed by the Engr-in-Charge. |
| 17 | Taking down chowkhat or frames with shutters any type (wooden/Alu/Steel) (without taking off shutters from the frame)exe 1.5 Sqm but n exc 4 Sqm each etc complete all as specified and as directed |
| 18 | Taking down chowkhat or frames with shutters any type (wooden/Alu/Steel) (without taking off shutters from the frame) not exe 1.5 Sqm each complete all as specified and as directed. |
| 19 | S&F Pressed steel frames for doors(105x60) mmwith one or more rebates including necessary fixing lugs, hinges, lock strike plateetc complete all as specified and as directed. |
| 20 | M&L Cutting holes in brick walls built in cement mortar for inserting hold fasts and making good dismantled portion in CM 1:3 or cement conc 1:2:4 type B1 as required exc half brick but not exc full brick wall complete all as specified and as directed. |
| 21 | M&L PCC 1:3:6 type C-1 (using 20mm graded stone aggt) as in filling in holes of hold fasts and back filling of chowkats complete all as specified and as directed. |
| 22 | M & L Secound class hardwood Plain, solid, straight chowkats and frames wrought framed rebated on the solid, rounded or chamfered, put together with glue pinned at joints, all as directed. |
| 23 | S&F 18/19 mm thick prelaminated particle board interior grade prelaminated (celuka ply )one side with decorative choice laminations and other side balancing white lamination fixed with screws to timber frame work including piano hinges& magnet door catcher for each shuttter etc complete all as specified and as directed by Engr-in-Charge. |
| 24 | S&F Hasp & staple safety type aluminium anodized with mild steel hing pin incl bolt to hing plate and fixed with screws 100mm size etc complete. |
| 25 | M&L, aluminium Anodised aluminiumframe for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc. complete all as specified |
| 26 | M&L foraluminium Anodised aluminium door shutters, aluminium section weighing 0.55 kg/ m including necessary joining cleats, glazing clips, ruber neoprene packing, handles 2 Nos in each door, hinges, anodised aluminum snap beading screws etc. S & F 5.5 mm thick tinted glass in panel of shutter fixed with glazing clips , rubber gasket and powder coated aluminium snap beading so as to make air tight and including S & F powder coated butt hinges type C-1,100 mm size 3 nos per shutter , powder coated aluminium handle of 150mm size 2 Nos (One on each side of shutter) , powder coated aluminium tower bolt of size 200 mm ( 2 Nos ) per shutter ,mortise lock , brass body ,6 levers ( 1 No) with duplicate keys, aluminium (extruded section) hydraulic door closer regulated designation No-3 Universal type ( 1 No) & Floor door stopper ( 140 mm ) overall ,aluminium body 1 No on each shtteretc complete all as specified and as directed. Note: (i) Cost of all fittings & fixture shall deemed to be included in unit quoted rate by the tenderer . (ii) The minimum thickness of powder coating shall be 50 Micron complete all as specified and as directed |
| 27 | S&F of 35mm thick 2nd class Hard wood paneled door shutter factory made (two panel) with lock rail andpanel of 9mm thick BWP commercial ply wood, the size of rail and stile is as per IS 1003 (Part-I), Kiln seasoned and chemically pressure treated. |
| 28 | S&F factory made fabricated 35 mm thick IInd class HW partly paneled& Partly gauged & skeleton shutters open rebated and prepared to receive glass/gauge etc. (without sash bars) edges of framing plain chamfered or rounded fitted with cut & mitered beads for security glass/gauge etc. size of members of shutter as specified in SSR Pt I sec 8 Cl 8.20 (a),divided into squares with plain chamfered rounded, mitered and rebated sash bars etc complete all as specified and as directed |
| 29 | S&F stainless steel wire cloth 0.63 mm nominal dia of wire and avg width of a-pertare 1.40 mm fixed with tinned tacks or galvanized wire staples etc complete all as specified and as directed. |
| 30 | M&L for preparation new wooden surface of any description not otherwise described over 10 cm width or girth and applying two coat synthetic enamel paint over one coat of pink primer etc complete all as specified and as directed |
| 31 | S&F for powder coated side hige type aluminium window with double shutter (one glazed & one gauzed) incuding fabricated out frame work of required size and frame having weight not less then1.6Kg/RM without sash bars made of shutter section weighing 0.55 Kg/m including providing necessary powder coated aluminium fittings like joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittings such as peg stays150mm long (1 Nos), hinges types C-21, 100 mm long (02 Nos) aluminium handle (01 Nos) per shutter etc including 4.80mm thick plain selected quality glass, stainless steel steel wire cloth 0.36mm dia steel wire and apperture 1.40mm etc complete and as directed. NOTE : (i)The minimum thickness of powder coating shall be 50 micron. (ii) Cost of all fittings & fixture shall deemed to be included in unit quoted rate by the tenderer. |
| 32 | S&F stainless steeltower bolts of extruded section & fixed 150 mm long etc complete all as specified and as directed |
| 33 | S&F stainless steel handles cast type anodized 150 mm size etc complete all as specified and as directed |
| 34 | S & F butt hinges medium weight cold rolled, mild steel and fixed 75 mm size etc complete all as specified and as directed. |
| 35 | S&F 300 mm long stainless steelsliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or castcomplete all as specified and as directed. |
| 36 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises and complete all as specified and as directed. |
| 37 | M&L for screed bed or bedding layer in CM 1:6, 15mm thick complete all as specified and as directed. |
| 38 | M&L for 25 mm thick PCC 1:2:4 type B1 (using 20 mm graded stone aggregate) as in sub floor finishing cement concrete surface even and smooth using extra cement complete all as specified and as directed. |
| 39 | M&L for coloured ceramic tiles 7 to 8 mm thick (square / rectengular) area of each tile exceeding 0.36 sqm but not exc 1.00 sqm, in floors etc. set and jointed in neat cement slurryand pointed in white or coloured cement to match to floor etc completeall as specified and as directed. |
| 40 | M & L Machine cut kota stone slab flooring 18-20mm thick over and including 20mm thick cement screed bed in CM 1:6 laid laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and as directed. |
| 41 | M & L rendering 10mm thick in cement mortar (1:3) on fair faces of brick work or concrete surfaces as in vertical surfaces for receiving tiles as directed. |
| 42 | M&L for coloured ceramic tiles 7 to 8 mm thick (square / rectengular) area of each tile exceeding 0.36sqm but not exc 1.00 sqm, in dado/Skirting etc. set and jointed in neat cement slurryand pointed in white or coloured cement to match to floor etc completeall as specified and as directed. |
| 43 | M & L Machine cut kota stone slab flooring 18-20mm thick in riser of steps,skirting, dado & pillar over and including 10mm thick rendering in CM 1:4 laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and as directed. |
| 44 | M&L for 18-20mm thick Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window cills, cooking platforms and like including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite over 15 mm thick in CM(1:6) etc completed all as specified and directed. |
| 45 | Demolition of PCCin any description and in any positionetc complete all as specified and as directed at site |
| 46 | M&L for 75mm thick cement concrete type C-2, 1:3:6 (20mm graded aggregate) as in plinth protection finished even and smooth without using extra cement complete all as specified and as directed |
| 47 | S & F for vitreous China Ware Wash hand basin white ( table top ), flat back, size 550 x 400 mm size(flat back or angle back type)including cutting for and pinning ends of brackets or erecting stand and waste pipe and connected all iterms as requied etc complete all as specified and as directed by Engr-in-Charge. |
| 48 | S & F 1500mmx600mm bevelled edge mirror of selected quality glass, mounted on 6mm thick AC building board or commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers complete all as specified and as directed. |
| 49 | S&F PVC connections 15mm size with PTMT nuts of length 450mm etc complete all as specified and as directed. |
| 50 | S&F in rep 15mm dia Concealed stop Cock regular body 15mm with flangecomplete all as specified and as directed. |
| 51 | S&F in rep 15mm bore cast copper alloy chromium plated angle cock with flangecomplete all as specified and as directed. |
| 52 | S&F in rep 15mm bore fancy type chromium plated bib cock long body with flangeetc complete all as specified and as directed. |
| 53 | S&F CP mixer 15mm dia bore mixing hot & cold water for wash hand basin screwed down for iron pipe and fixedall as directed. |
| 54 | S&F PVC floor trap outlet dia 75mm with grating including jointing to waste pipe fixed in cement concrete type B1 (1:2:4) complete all as specified and as directed. |
| 55 | S&Fcromium plated towel rail 20mm dia, D type, 60cm long between flanges complete all as specified and as directed |
| 56 | S&F stainless steel kitchen plate rack overall size 900mm x 900mm make out of 0.80mm thick stainless steel sheet etc complete. |
| 57 | S&F stainless steel sink with drainage board 1.00mm thick for kitchen or laboretory with plug, waste pipe, coupling, washers also incl cantilever cast iron brackets connecting union etc, overall size 915x460mm with bowl size 410x330x160mm complete. |
| 58 | Supply and fix CP corner glass shelf with bracket fixed with screws complete all as specified and as directed by Engineer-in-Charge . |
| 59 | S&FCP Brass soap dish fixed to wall with cp brass screws etc complete all as specified and as directed by the Engineer-in-Charge |
| 60 | S&F 25 mm dia chromium plate curtain rod with CP brackets and knobs at both end as per sample approved by Engineer-in-charge. |
| 61 | Demolition of RCCof any description and in anypositionnot otherwise specifically provided for complete as all specified and as directed by Engr-in-Charge. |
| 62 | M&L for Reinforced cement concrete (nominal mix) Type B1 1:2:4 (20 mm graded aggregate)inSlabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves including formwork as requred complete all as specified and as directed by Engr-in-Charge. |
| 63 | S&F for Mild steelTMT bars 8 mm dia., and over cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia., or securing with clips complete all as specified and as directed by Engr-in-Charge. |
| 64 | Demolition and breaking up drain pipes (Salt glazed ware, AC/PVC/CI or Reinforced concrete) set in cement mortar in floors or wall in 100mm dia meter complete all as specified and as directed. |
| 65 | S &F of 110mm dia PVC (SWR) pipes single socketed, in any length with rubber ring joints laid in trenches or in floors or wall with necessary iron clipsand complete all as specified and as directed. |
| 66 | S &F of 75mm dia PVC (SWR) pipes single socketed, in any length with rubber ring joints laid in trenches or in floors or wall with necessary iron clips and complete all as specified and as directed. |
| 67 | S&F PVC (SWR) bends any radius 110mm bore. |
| 68 | S&F PVC (SWR) bends any radius 75mm bore. |
| 69 | Dismantling water tanks and removing to store of steel/PVC of capacity exceeding 500 ltr but not exceeding 1000 Ltr complete all as specified |
| 70 | S&F 1000 ltr capacity or rotational moulded polyethylene water storage tank (cylindrical vertical with closed top) ISI marked or make specified, two layered construction hoisted and fixed in position including S&F 20mm dia GI pipe medium grade washout pipe 450mm long with plug and 20mm dia gi pipe medium grade overflow pipe 600mm long with fittingcomplete all as specified in SSR Part -I complete all as specified and as directed |
| 71 | S&F 20mm bore ball valve high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball screwed for iron pipe and fixed (Minium weight 210 gms ), complete all as specified and as directed |
| 72 | S & F 20mm dia Gun metal gate valve with iron wheel head, screwed both ends for iron pipe complete all as specified and as directed. |
| 73 | S&Ffalse ceiling with 4 mm thick gypsum board tiles laminated with white PVC film on face side & metalized polyster film (Aluminium foil) on the back side with all four edges sealed with PVC filmof size 600 x 600 mm (595 X 595 mm) fixed with clips & screws including anodised aluminium snap grid frame work for false ceiling of Tee/Angle of weight not less than 150 gm per RM with slot for fixing including necessary suspender of flat iron or 4 mm dia bars of required length fixed in purlin of roof not exceeding 1.20 m both ways including all accessories required for suspending ceiling work and gypsum board complete all as specified and as directed by the Engineer-in-Charge. |
| 74 | S&F forhollow PVC Wall lining consisting of 5 mm thick plain colourPVC sheet inclusive of solvent cement and fixing at site of 5mm thick PVC sheet fillet of width 35mm for wall panelling inclusive of fixing on to wall to PVC frame complete all as specified and as directed |
| 75 | Taking up or down existing steel tubing and connections including cleaning for refixing or removal to store complete all as specified and as directed for the following sizes:- |
| 76 | (a) 15 mm dia bore |
| 77 | (b) 20 mm dia bore |
| 78 | Supplying, fixing, jointing and testing galvanised iron tubing medium grade with all fitting such as bends, elbow, socket, reducer etc and fixed to wall or laid in floor complete all as specified and as directed for the following sizes:- |
| 79 | (a) 15 mm dia bore |
| 80 | (b) 20 mm dia bore |
| 81 | Fixing only old steel tubing and connections obtained from taking down against item No 8(a) & (b) herein before in new or old position fixed to wall, ceiling or laid in floor with new fittings for the following sizes:- |
| 82 | (a) 15mm dia bore |
| 83 | (b) 20mm dia bore |
| 84 | Cutting chases, pinning in, making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels etc., and cutting chases for concealed water tubing or concealed conduit wiring, etc., and making good, cutting exceeding 10 cm but not exceeding 20 cm girth in brick walls |
| 85 | Taking down carefully copper/ aluminium point wiring (light, fan, socket, or power) complete fitting such as switches, ceiling roses pendants, regulators, sockets, light fitting ceiling fan etc to be measured seperately ) removing materials for keeping in safe custody or for taking credit (credit for above items should be made as per conditions seperatly) and making good disturbed surface of walls floors etc complete all as specified and as directed.Note-Responsibility after taking down fan/exhaust fan keep in safe custody of contractor and refix the same afterbefore completion of work the rate of same deemed to be included in the item quoated rate. |
| 86 | Taking down carefullyexisting wooden board , Main switch, MCB DB boxes with MCBs, sheet metal boxes, cut out, etc of any size anycapacity fromboards completeall as specified and as directed. |
| 87 | Taking down carefully sub main wiring / service connection twin core from wall / LT pole of any size of Aluminum with wooden batten and or through rigid conduit including GI wire and making good the disturbed surfaces of walls, roofs, floors etc complete all as specified and as directed. |
| 88 | M & L for concealed point wiring complete with PVC insulated and unsheathed flame retardant low smoke and halogen ( FRLSH ) cable of 1.5 sqmm (nominal area) with multi stranded copper conductor single core 1100 volts grade in and including rigid PVC conduit not less than 20 mm dia, clip, with MS terminal boxes (not less than 1.6mm thick) and painted with one coat of red oxide primer all around and two coats of black bituminous paint from out side and two coat of aluminum paint from in side including common earth dollywith3 mm thick plastic laminated sheet top cover of approved make and colour including 1.5 sqmm green multi stranded copper conductor as continuous earth wire with lugs complete including cutting necessary chases on wall / ceiling surfaces for drawing of conduit & cables as required and making good disturbed surfaces of walls with CM 1:3:6 and matching with the existing surfaces including colour washing complete all as specified and as directed for the following :- |
| 89 | (a) One light point controlled by one switch |
| 90 | (b) One fan/exhaust point controlled by one switch & regulator. |
| 91 | (c) One 3/5 pin5 Amp socket outlet point controlled by one switch on independent board. |
| 92 | (d) One 3/5 pin5 Amp socket outlet point controlled by one switch on same board. |
| 93 | S&F modular socket 20 amp with MCB 20 Amp \"C\" type all specified and complete. (For geyser) |
| 94 | Description all as per item No 82 above but using 2.5 sqmm single core multi stranded copper conductor PVC insulated and unsheathed flame retardant low smoke ( FRLS ) cable for 3/6 pin 15 Amp socket outlet controlled by one switch on independent board with 2.5 sqmm green stranded copper conductor as continuous earth wire with lugs complete all as specified and as directed. |
| 95 | S&F switch pianoflush button type 5 Amp single pole one waycomplete all as specified and asdirected. |
| 96 | S&F socket outlet 2in1, 3 pin, 5 Amp flush type complete all as specified and asdirected. |
| 97 | S&F switch piano flush button type 15 Amp single pole one way complete all as specified and asdirected. |
| 98 | S&F socket outlet2in1, 3 pin, 5 Amp and 15 Amp flush type complete all as specified and asdirected. |
| 99 | S & F delux Fan Regulator electronic rotary, step type 240 Volt50 Hz,complete all as specified and as directed. |
| 100 | S & F Lamp holder,PVC/Urea type with back plate suitable for batten fittingscomplete all as specified and as directed |
| 101 | S & F 9W/10W LED retrofit lamp B-22 holder base with polycorbonate body and aluminium heat sink complete all as specified and as directed. |
| 102 | S&F ceiling rose,surface POLYCARBONATE 63 x50mm three terminals completeall as specified and asdirected. |
| 103 | M&L, sub main wiringwith two single core PVC insulated unsheathed FRLSH confirming to IS 694:2010, multi stranded copper conductor (ISI marked with valid CML No), cable 1100 Volt grade, 6 sqmm size drawn in and includingnon metallic rigid PVC concealed conduit medium grade (ISI marked with valid CML No) not less than 25 mm dia with all fitting & fixing accessories including one run single core PVC insulated unsheathed 6 Sqmm FRLSH confirming to IS 14930 (Part-I) 2001, copper conductor (ISI marked with valid CML No) colour code as a earth continuity and connected upto DB complete all as specified and as directed.(NOTE: (i) Two run of single core PVC cable with one run of earth conductor and conduit shall be measured as one unit and the quoted rates shall be deemed to be inclusive for cutting chasesin wall/pillars/columns etc. of any description for concealing the conduits to required depth & making good the disturbed surface in cement mortar 1:4 including finishing the surface with putty to match with the existing surface. |
| 104 | S&F TPN DB-DPX 125 MCCB DBs 4 way single door with provision for DPX 125 MCCB andas incomer and SP/TP MCBs as out going no of modules DPX 125+12, concealed complete all as specified and as directed. Make:- ABB / Havells / HPL / Standard. |
| 105 | Supply and fix MCCB having breaking capacity of of 16 KA 415V, 4 pole having rating capacity of 100 Amp 100% ICU complete all as specified and as directed. |
| 106 | S&F sheet metal enclosure double doorconcealed suitable for distribution boards when MCBs to be used having 100 Amp rated bus bar SPN DB 8 ways 240 V complete all as specified and as directed . |
| 107 | S&F MCB single pole and neutral 40 Amp/63 Amp 240 V ,10KA , \"C\" series, complete all as specified and as directed with copper lugs |
| 108 | S&F MCB single pole 6 to 32Amps 240 V,10KA, \"C\" series, complete all as specified and as directed |
| 109 | Supply and fixing in repair 22 W LED 6000k Decorative ultra slim linear LED fitting fixture with extruded polycarbonate ,environmental friendly ,energy efficentinterated driver and 28watts lamp fitted including wiring upto and terminal into ceiling rose complete all as specified and as directed by Engr-in- Charge. |
| 110 | Supply and fix LED 35/36 W building security light fitting,5700 K energy saving & environmental friendly long life versatile pressure die cast aluminiumIP 66.road way luminare with high power LEDs as light source and electronic driver suitable for pole dia 35 mm including 35 mm dia light grade tube bracket ,bend to shape 1.80 mtrlength with two nos of clamps of size 50mm x 6mm with nuts and bolts,washers etcincluding connection with 1.5sqmm threesinglecorePVC insulated and PVC sheathed cable stranded copper cable upto ceiling rose and fixing on walls/pole complete all as specified and as directed. |
| 111 | Supply and Fixing Exhaust fans AC single phase 230/240V of size 300 mm sweep, 1250-1350 RPM with louvre complete including with all arrangement of making holes on wall, making good and finishing of disturbed surfaces matching with the existing surfaces, necessary fixing arrangement such as fastener bolts, nuts, washers etc, of appropriate size complete all as specified and as directed |
| 112 | S&F BLDC Ceiling fan complete with three aluminium blades down rod, snackel clamp, reel insulator, fan canopy split pin and accessories 230 V, 1200mm sweep with service value not less than 7.8, power consumption not more than 28 watt and minimum air delivery of 220 CMM, BEE 5 star rated, two core PVC insulated copper wire white sheathed of size 0.5 sqmm from fan connector to ceiling rose complete all as specified and as directed. NOTE:-(i) Writing MES no in 20mm letter size with black paint etc is deemed to be included in quoted rate.(ii) Old fan deposit in store yard. |
| 113 | M&L for earthing completewith galvanisedsteelearth plateelectrode of size 600 mm x 600 mm x 6 mm thickweithing not less than 17.5 Kg buried directly in ground (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of the plate not less than 1.5 mtr below ground level, connected to galvanized earth lead wire 4.00 mm dia by means of bolts nuts check nuts & washers of galvanized iron or steel , procteded by GI pipe 15 mm bore( light grade)and watering pipe 20 mm bore GI pipe(light grade) andchamber of pcc 1:4:8 type D2 using 40 mm graded stone aggregate and coping shall be in PCC 1:3:6 type C1 using 20mm graded stone agg.50 mm thick cover of RCC 1:2:4 type B1 using 20 mm graded stone agg. reinforced with 8 mm dia MS tor bar @ 80 mm c/c both ways including excvation and earth work and removal of surplus soil complete all as shown in electrical plate no 3 of SSR PT 1, 2009 with charcoal dust and saltcomplete and earth leadconnected to earthing test point (up to main switches, DBs) completeall as specified &testing on completion. NOTE:-(i)item includes the cost of 7.5 mtr length GI pipe for protection for GI earth wire. (ii) item rates includes the cost of 7.5 mtr earth lead GI earth wire. (iii)PCC pit shall be provided at least 500mm away from the pit and not on the earth pit itself and the extra costof additional length of watering pipe,bends,elbow etc shall be deemed included in the unit rate. |