Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | Site Clearance |
| 2 | Clearing Grass and Removal of Rubbish.Site Area |
| 3 | Building |
| 4 | Earth work in excavation in foundation and trenches etc. in all kinds of soil (excluding soil containing 50% or more of shingle or small size boulders upto 30 cm size, saturated soil and rock), lift upto 1.50 m and stacking the excavated soil not more than 3 m clear from the edge of the excavation and returning the stacked soil in 15 cm layers, when required, into plinth sides of foundation etc consolidating each deposited layer by ramming and watering and then disposing of all surplussoil as directed within a lead of 50m.All kinds of soil. |
| 5 | Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1:2 (1 cement : 2 Coarse sand) to match the existing floor: With Chlorpyriphos/ Lindane E.C. 20% with 1% concentration |
| 6 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. |
| 7 | Filling in plinth with sand under floors including watering, ramming, consolidating and dressing complete. |
| 8 | Providing and laying in foundations and plinth cement concrete 1 : 5 : 10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) excluding the cost of centring and shuttering |
| 9 | Providing and laying cement concrete 1 : 3 : 6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) excluding the cost of centring an shuttering in: a) Foundations and plinth |
| 10 | Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work;using coarse aggregate and fine aggregate derived from natural sources,portland Pozzolana/Ordinary Portland/Portland Slag cement,admixtures in recommended proprtions as per IS:9103 to accelerate/retard setting of concret,to improve durability and workability without imparing strenght:including pumping of concrete to site of laying,curing,carriage for all leads:but excluding the cost of centuring,centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge:for the following grades of concrete. All Works upto Plinth Level.Concrete of M30 grade with Minimum Cement of 350 Kg/Cum, |
| 11 | Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland/Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete. Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 1.10 times of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement.All works above plinth level upto floor V level Concrete of M25 grade with minimm cement content of 350 kg /cum |
| 12 | Centring and shuttering including strutting proping etc. and removal of form work for:Foundations and plinth. |
| 13 | Centering and shuttering including strutting, propping etc. and removal of form for : Columns, pillars and piers. |
| 14 | Centering and shuttering including strutting, propping etc. and removal of form for : Lintels, beams, plinth beams, girders,bressumers and cantilevers |
| 15 | Centering and shuttering including strutting, propping etc. and removal of form for : Suspended floors, roofs, landings, balconies and access platform |
| 16 | Reinforcement of RCC work including bending, binding and placing in position complete.b) Tar/TMT steel |
| 17 | Brick work with best available local bricks in foundations and plinth in cement mortar 1:6 (1 cement : 6 fine sand) |
| 18 | Brick work with best available local bricks in foundations and plinth in cement mortar 1:4.Add Extra for brick work with best available local bricks in superstructure above plinth level up to floor two level. |
| 19 | Extra for brick work with best availablel ocal bricks insuperstructure above plinth level up to floor two level |
| 20 | Half brick masonry (with best available local bricks) in cement mortar 1:4 (1 cement : 4 coarse sand) in foundation and plinth.Add Extra for half brick masonry in superstructure above plinth level and up to floor two level. |
| 21 | Extra for half brick masonry in superstructure above plinth level and up to floor two level |
| 22 | 6 mm cement plaster of mix :1:3 (1 cement: 3 fine sand) |
| 23 | 12 mm cement plaster:1:6 (1 cement: 6 fine sand) |
| 24 | 15 mm cement plaster 1 : 6 (1 cement : 6 fine sand) on the rough side of single or half brick wall. |
| 25 | 6 mm cement plaster finished with a floating coat of neat cement of mix : 1:4 (1 cement: 4 fine sand) |
| 26 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), including grouting the joints with white cement and matching pigments etc., complete.Size of Tile 600x600 mm |
| 27 | Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels.a) Raj Nagar Plain white marble/ Udaipur green marble/ Zebra black marble.Area of slab over 0.50 sqm |
| 28 | Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels.a) Raj Nagar Plain white marble/ Udaipur green marble/ Zebra black marble.Area of slab over 0.50 sqm |
| 29 | Making plinth protection 50 mm thick of cement concrete 1 : 3 : 6 (1 cement : 3 coarse sand : 6 stone aggregate using 20 mm nominal size) over 75 mm bed of stone ballast 40 mm nominal size well rammed and consolidated and grouted with fine sand including finsihing the top smooth.Plinth Protection |
| 30 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes.110mm diameterFrom Terrace to Ground Floor |
| 31 | Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessoriessuch as nuts, bolts, fasteners etc.). |
| 32 | Providing approved best available local wood(Class BII) work in frames of doors,windows,clerestory windows and otherframes, wrought framed and fixed in position. |
| 33 | Providing and fixing 44 mm thick best available local wood Class-B I(19 mm batten and 25 mm bracing) battened and braced doors and windows shutters including providing and fixing necessarybright finished or black enamelled T-hinges, butt hinges, sliding door bolts, tower bolts and handles with necessarybolts and screws complete. |
| 34 | Providing and fixing MS round or square bars at required spacing in wooden frames of windows and clerestory windows.For windows and ventilators |
| 35 | Providing and fixing rolling shutters of approved make, made of 80x1.25 mm MS laths interlocked together through their entire length and jointed together at the end by end locks mounted on specially designed pipe shaft with brackets, size guides and arrangements for inside and outside locking with push and pull operation complete but excluding the cost of top cover and spring |
| 36 | Providing two coats of acrylic water based wall putty/ wall filler of Asian Paits/ Berger/Dulux over concrete/ cement plaster/ brick walls and ceilings both internal and external after removing all the loosely adhering material from the wall/ ceiling surface with the help of emery stone, putty blade or wire brush, moistening the wall with the help of sufficient quantity of clear water as specified and directed by the department. |
| 37 | Distempering (two or more coats) with oil bound washable distemper of approved brand and manufacture and of required shade on new work over and including a priming coat with distemper primer of approved brand and manufacture to give an Two or more coats on new work |
| 38 | Finishing walls with 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives. New work (Two or more coats applied @ 1.43 litre/ 10 sqm. Over and including priming coat of exterior primerapplied @ 0.90 litre/10 sqm. |
| 39 | Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying :(a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/ sqm. This layer will be allowed to air cure for 4 hours(b) Second layer of slurry of cement @ 0.242 kg/sqm mixed with water proofing cement compound @ 0.126 kg/sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours(The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry.) Toilet Sunken Portion |
| 40 | Providing and laying four courses water proofing treatment with bitumen felt over roofs consisting of first and third courses of blown or/and residual bitumen applied hot @ 1.45 kg. per. sqm of area area for each courses, second course of roofing felt type-3 grade-I(hessian base self finished bitumen felt) and fourth and final course of stone grit 6 mm and down size or pea size gravel spread at 6 cudm per sqm including preparation of surface excluding grading complete. |
| 41 | Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting,fixing in position and applying a priming coat of approved steel primer all complete. |
| 42 | Providing and fixing water closet squatting pan(Indian type WC Pan) with 100 mm sand cast Iron P or S trap, 10 litre low level white PVC flusing cistern, including flush pipe, with manually controlled device(handle lever) conforming to IS:7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required:a) White vitreous china orrisa pattern WC pan of size 580x440 mm with integral foot rests.W.C. pan with ISI marked black solid plastic seat and lid |
| 43 | Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340X430X265 mm sizes respectively with CI automatic flushing cistern with fittings, RS or CI brackets standard size galvanized steel flush pipe and spreaders with brass unions and GI clamps complete including pfittings, cutting and making good the walls and floors where required. One urinal basin with 5 lt CI automatic flushing cistern |
| 44 | Providing and fixing white vitreous china wash basin with RS or CI brackets painted white15 mm CP brass pillar taps and CP brass chain with rubber plug 32 mm CP brass waste of standard pattern, 32 mm dia CP brass trap and MI unions complete, including cutting and making good the walls where required.Flat back wash basin size 550x400 mm with single |
| 45 | Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steelplug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required :Kitchen sink with drain board.510x1040 mm bowl depth 250 mm |
| 46 | Providing and fixing CP Brass 32mm size Bottle Trap of approved quality & make and as per the direction of Engineer-in-charge. |
| 47 | Providing and fixing Differecially abled toilets including Wash basin, Water closet,Cistern, grab bars & hand rails etc. The rate include cost of all material & labour involved in the item complete and all as per direction of engineer incharge. |
| 48 | Providing & fixing PVC waste pipe for sink including PVC waste fitting Complete.Semi rigid pipe. 40mm Dia |
| 49 | Providing and fixing 600x450 mm bevelled edge mirror or superior glass (of approved quality) complete with 6 mm thick asbestos sheet ground fixed to wooden cleadt with CP brass screws and washers. |
| 50 | Providing and fixing CP brass single lever low flowwall mounted Sink mixer with 15 mm CP brass single lever swivel spout with waste complete including cutting and making good the walls where required. The rate include cost of all material & labour involved in the item complete and all as per direction of engineer incharge. (MAKE-JAQUAR - Model CON-319KN) or Equivalent. |
| 51 | Providing & fixing wall mounted 300mm Long SS Grab Bar including cutting & making good the walls. ( MAKE-1:JAQUAR, MODEL NO. GRAB BAR : AKP-CHR-35701PS OREQUIVALENT.) |
| 52 | Providibng and fixing straight type Macfit single body push fit type WC pan connector with factory supplied spring loaded seal guard of integral single mould sealing fins made of flexible EVA body, including bush/adaptor for use with C.I. Pipe as supplied with the pan connector. |
| 53 | Providing and fixing cast brass Floor cleanout plug with suitable insert keys for opening in brass cap, male threaded joint/reducer with G.I. socket caulked to Pipe/fittings of CI pipe including cost of lead joints etc. complete in all respect. 100 mm dia |
| 54 | Providing and fixing GI inlet fitting with maximum 3 inlets 32,40 or 50 mm size fabricated from 100 dia GI pipes and sockets,fixed to C.I. trap with Drip Seal joint and set in cement concrete as per standard drawing complete as directed by Engineer-incharge. |
| 55 | Providing and fixing SS Grating of 125 mm dia of approved quality and colour complete as per direction of engineer in charge. Circular Type. 125 mm nominal dia with 25 mm waste hole |
| 56 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply, including all CPVC plain and brass threaded fittings. This includes jointing of pipes and fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer-in-charge.Internal work-exposed on wall, including fixing the pipe with clamps at 1.00 meter spacingi)15 mm nominal outer dia Pipes |
| 57 | 20 mm nominal outer dia Pipes |
| 58 | 25 mm nominal outer dia Pipes |
| 59 | 32 mm nominal outer dia Pipes |
| 60 | 40 mm nominal outer dia Pipes |
| 61 | Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :i) 20mm nominal bore |
| 62 | 25 mm nominal outer dia Pipes |
| 63 | 32 mm nominal outer dia Pipes |
| 64 | 40 mm nominal outer dia Pipes |
| 65 | 50 mm nominal outer dia Pipes |
| 66 | 60 mm nominal outer dia Pipes |
| 67 | Providing and fixing uplasticised PVC connection pipe with brass unions :45 cm length,15 mm nominal bore. |
| 68 | Constructing masonry Chamber 30x30x50 cm inside, in brick work in cement mortar 1:4 (1 cement :4 coarse sand) for stop cock, with C. I. surface box 100x100 x75 mm (inside) with hinged cover fixed in cement concrete slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), i/c necessary excavation, foundation concrete 1:5:10 ( 1 cement : 5 fine sand : 10 graded stone aggregate 40mm nominal size ) and inside plastering with cement mortar 1:3 (1cement : 3 coarse sand) 12mm thick, finished with a floating coat of neat cement complete as per standard design : With common burnt clay F.P.S.(non modular) bricks of class designation 7.5 |
| 69 | Providing and fixing 15 mm nominal bore C.P. brass angle valve for basin mixer and geyser points of approved make conforming to IS : 8931 |
| 70 | Cutting holes up to 15x15 cm in R.C.C. floors and roofs for passing drain pipe etc. and repairing the hole after insertion of drain pipe etc. with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), including finishing complete so as to make it leak proof. |
| 71 | Making hole up to 20x20 cm and embedding pipes up to 150 mm diameter in masonry and filling with cement concrete1:3:6 (1 cement : 3 coarse sand 6 graded stone aggregate 20 mm nominal size) including disposal of malba. |
| 72 | Disinfecting C.I. water mains by flushing with water containing bleaching powder @ 0.5 gms per litre of water and cleaning the same with fresh water, operation to be repeated three times including getting the sample of water from the disinfected main tested in the municipal laboratory.100 mm diameter C.I. pipe |
| 73 | Providing and fixing non-return valve of approved quality. 80 mm dia. |
| 74 | Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete :150 mm dia. R.C.C. pipe |
| 75 | Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) all-round S.W. pipes including bed concrete as per standard design 150 mm diameter S.W. pipe : |
| 76 | Providing and fixing square- mouth S.W. gully trap class SP-1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design. 180 x 150 mm size P type,With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 |
| 77 | Constructing brick masonry manhole with 2nd class bricks in cement mortar 1 : 5 (1 cement :5 fine sand) RCC top slab with 1 : 2 : 4 mix (1 cement : 2 coarse sand : 4 stone single 20 mm nominal size), foundation concrete 1 : 4 : 8 mix (1 cement : 4 coarse sand : 8 stone aggregate 40 mm nominal size) inside plastering 12 mm thick with cement mortar 1 : 3 (1 cement : 3 coarse sand) finished with a floating coat of neat cement and making channels in cement concrete 1 : 2 : 4 mix (1 cement : 2 coarse sand : 4 stone aggregate 20 mm nominal size) neatly finished complete as per standard design. a) Inside size 90 x 80 cm and 45 cm deep including CI cover with frame (light duty) 455 x 610 mm internal dimensions total |
| 78 | Constructing brick masonry road gully chamber of specified size with common burnt clay(non modular) bricks of class designation 7.5 in cement mortar 1:4 ( 1 cement : 4coarse sand) including precast R.C.C. horizontal grating with frame complete as per standard design: Chamber size 50x45x60 cm including precast R.C.C grating with frame 500x450 mm horizontal grating |
| 79 | Making soak pit 2.5 m diameter 3.0 metre deep with 45 x 45 cm dry brick honey comb shaft with bricks and S.W. drain pipe 100 mm diameter, 1.8 m long complete as per standard design. |
| 80 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i)Single socketed pipes. 110 mm diameter |
| 81 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. Roof top PVC water tank(Considering 200 lt per capita water consumption per day) |
| 82 | Electrical Items |
| 83 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) a) 8 way, Double door |
| 84 | b) 12 way, Double door |
| 85 | Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/ Isolator) a) 8 way Double door |
| 86 | Supplying and fixing following rating, Four pole, 415 volts, MCB in the existing MCB DB complete with connections, testing and commissioning etc as required complete in all respect. A) 63 Amps |
| 87 | Supplying and fixing following rating, Double pole, 415 volts, MCB in the existing MCB DB complete with connections, testing and commissioning etc as required complete in all respect. A) 40 Ams |
| 88 | Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, \"C\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.. A) Single pole |
| 89 | Supplying and fixing following rating, double pole, single phase and neutral, 240 volts, residual current circuit breaker ( RCCB), having a sensitivity current upto 30 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc as required.A) 63 Amps |
| 90 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FR PVC insulated copper conductor single core cable etc as required.. (For voltage grade upto 1100V as per IS:694) a) Group – C |
| 91 | Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point (without independent switch etc.) with1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, and earthing the pointwith 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required.. (For voltage grade upto 1100V as per IS:694).a) Group – C |
| 92 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required . (For voltage grade upto 1100V as per IS:694). 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire |
| 93 | 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire |
| 94 | 2 X 6 sq. mm + 1 X 6 sq. mm earth wire |
| 95 | 2 X 10 sq. mm + 1 X 6 sq. mm earth wire |
| 96 | 2 X 16 sq. mm + 1 X 6 sq. mm earth wire |
| 97 | 4 x 10 sq.mm + 2 x 6sq.mm. earth wire |
| 98 | 4 x 16 sq.mm + 2 x 6sq.mm. earth wire |
| 99 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required. (For light plugs to be used in residential buildings). |
| 100 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required. |
| 101 | Supplying & fixing suitable size GI box wih modular plate and cover in front on surface or in recess including providing andfixing 25 A modular socket outlet and 25 A modular SP MCB, \"C\" curve including connections, painting etc. as required. |
| 102 | Supply of 4ft Linear Suspended/Surface diffused LED luminaire with system power [28W ± 5%], dimension should not be more than 1220 x 35 x 35mm should be available in 3000K/4000K/6000K color temperature operational voltage range of 90-265V, power factor > 0.9, THD < 10%, Inbuilt surge protection of 2.5 KV, Luminaire has Ingress protection of IP20 The luminaire should have minimum lumen outputof 2200 lumens , CRI of >80 . The LEDs used have a life of 50000 burninghrs Lumen maintenance as per L70B10 with SDCM<=3 binningLuminaire performance & Safety :IEC 60598, IS 10322-5, IS 161-03/05/06/07, Surge : IEC 61000-4-5, IES, LM 79, LM 80, & TTC certificates will be provided from NABL accredited lab.Certification: CE Certified, Design Patented/Registered, ROHS compliant, BIS Certification for Luminaires & Drivers. |
| 103 | Supply, Installation, Testing and Commissioningof IP-65 rated 12W bulk head, Luminaire should be made of die cast aluminium with non corrosive SS fasteners.IK-08 Non yellowing UV stabilized translucent polycarbonate diffuser for glare free, uniform light distribution.Silicone gasket. Integral constant current power supply.CRI (Ra) : >80.Power Supply : Integral Power Factor : >0.95 THD : <10% Surge Protection : 2.5KV Efficiency : >85%. Frequency : 50-60Hz, Operating Voltage : 100-277Vac, Opaerating Temperature : -15°C~+50°C. Luminaire performance & Safety :IEC 60598, IS 10322-5, IS 161-03/05/06/07, Surge : IEC 61000-4-5, IES, LM 79, LM 80, & TTC certificates will be provided from in house NABL accredited lab.Certification: CE Certified, Design Patented/Registered, ROHS compliant, BIS Certification for Luminaires & Drivers |
| 104 | Supply, Installation, Testing and Commissioningof Recessed 2x2 LED luminaire with system power [40W ± 5%], Available in 3000K/4000K/6000K color temperature,madeof CRCA housing with aluminium front frame, must be equipped with Prismatic Acrylic diffuser UGR<21 . Powder coated with white epoxy polyester with operational voltage range of 180-240V, power factor > 0.95, THD < 10%, Inbuilt surge protection of 2.5 KV,Luminaire has Ingress protection of IP44 The luminaire should have minimum lumen outputof 4000 ± 10% lumens , CRI of >80 . The LEDs used have a life of 50000 burninghrs Lumen maintenance as per L70B10 with SDCM<=3 binning Luminaire performance & Safety :IEC 60598, IS 10322-5, IS 161-03/05/06/07, Surge : IEC 61000-4-5, IES, LM 79, LM 80, & TTC certificates will be provided from in house NABL accredited lab.Certification: CE Certified, Design Patented/Registered, ROHS compliant, BIS Certification for Luminaires & DriversINCOMER and BUS BAR.160 A 4P MCCB 25 KA : |
| 105 | Supply, Installation, Testing and Commissioningof IP-40 rated 18W LED ceiling recessed back-lit panel light - Indoor luminaire with soft uniform Light distribution. Luminaire should be made of die-cast aluminium for better thermal management. High efficiency diffuser for glare free, uniform light distribution. CRI (Ra) : >80, SDCM≤ 3 to avoid color deviation , Led life should be atleast L70B10 50,000hrsHigh lumen output (Delivered) of at least 100lm/w.High PF constant current LED driver with surge and thermal protection with follwoing ratings Power Supply : Integrated Power Factor : >0.90 THD : <20% Surge Protection : 2.5KV Efficiency : >83%.Suitable for operation on 240V, 50Hz single phase ac supply, Operating Voltage : 90-265Vac Operating Temperature : -15°~+50°C.Luminaire performance & Safety :IEC 60598, IS 10322-5, IS 161-03/05/06/07, Surge : IEC 61000-4-5, IES, LM 79, LM 80, & TTC certificates will be provided from in house NABL accredited lab.Certification: CE Certified, Design Patented/Registered, ROHS compliant, BIS Certification for Luminaires & Drivers |
| 106 | Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CM/M/W) minimum 6.00, Air delivery minimum 210 Cum/Min , 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required |
| 107 | Supplying of 300 mm sweep exhaust fan complete with all accessories etc as required complete in all respect |
| 108 | Supplying and fixing of 400 mm sweep Wall fan of colour White, Brown or Bianco complete with down rod or equivalent etc as required complete in all respect |
| 109 | Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required. Upto 450 mm sweep |
| 110 | Supplying and installation of metal enclosed wall/floor mounted front operated cubical type switch gear panel suitable for indoor installation conforming to IS: 8623 (Part I & II). The Panel should be made of CRCA sheet and thickness not less than 2mm (14 SWG). The panel shall be completely dust proof and shall be 7 tank chemical tretament powder coated for long lasting. All wiring shall be PVC insulated copper and PVC sheathed of 1100 volt grade of required size. The panel should have provision of entry of cable at the bottom and also provision of out going feeders from the bottom of the panel. The bus bar shall be of high quality Al. of uniform cross section. The panel shall consist of the following items (viz. Digital voltmeter, Digital ammeter, CT&PT, LED indicating lamps, selector switch etc.) connected as per drawing and shall be flush mounted on the front of the panel.INCOMER and BUS BAR 250 A 4P MCCB, 35 KA: |
| 111 | 250 A 4P On-load changeover switch: 2 Nos |
| 112 | Bus Bar 320 A TPN AL. Bus Bar : 3 Set |
| 113 | METERING & INDICATION:SELECTOR SWITCH : |
| 114 | DIGITAL AMMETER: |
| 115 | DIGITAL VOLTMETER: |
| 116 | CT & PT: 2 nos |
| 117 | OUTGOINGS, 160 A 4P MCCB 25 KA : |
| 118 | 100 A 4P MCCB, 25 KA: |
| 119 | 63A 4P MCCB 16 KA: |
| 120 | 40A DP MCB: |
| 121 | 32A DP MCB : |
| 122 | Building panel as described aboveSupplying and installation of metal enclosed wall/floor mounted front operated cubical type switch gear panel suitable for indoor installation conforming to IS: 8623 (Part I & II). The Panel should be made of CRCA sheet and thickness not less than 2mm (14 SWG). The panel shall be completely dust proof and shall be 7 tank chemical tretament powder coated for long lasting. All wiring shall be PVC insulated copper and PVC sheathed of 1100 volt grade of required size. The panel should have provision of entry of cable at the bottom and also provision of out going feeders from the bottom of the panel. The bus bar shall be of high quality Al. of uniform cross section. The panel shall consist of the following items (viz. Digital voltmeter, Digital ammeter, CT&PT, LED indicating lamps, selector switch etc.) connected as per drawing and shall be flush mounted on the front of the panel. |
| 123 | UPS panel as described above |
| 124 | Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.1 or 2 Module (75mmX75mm) |
| 125 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required |
| 126 | Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required. |
| 127 | Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. |
| 128 | Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. |
| 129 | Supplying and laying 6 SWG G.I. wire at 0.50 metre below ground level for conductor earth electrode, including connection/ termination with GI thimble etc. as required. |
| 130 | Providing and fixing 25 mm X 5 mm copper strip in 40 mm dia G.I. pipe FRLSom earth electrode including connection with brass nut, bolt, spring, washer excavation and re-filling etc. as required. |
| 131 | Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required. |
| 132 | Providing and laying earth connection from earth electrode with 6 SWG dia G.I. Wire in 15 mm dia G.I. pipe from earth electrode including connection with G.I. thimble excavation and re-filling as required. |
| 133 | Providing and fixing 25 mm X 5 mm copper strip on surface or in recess for connections etc. as required. |
| 134 | Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required. |
| 135 | Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required. |
| 136 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required.Upto 35 sq. mm |
| 137 | Above 35 sq. mm and upto 95 sq. mm |
| 138 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required.Upto 35 sq. mm |
| 139 | Above 35 sq. mm and upto 95 sq. mm |
| 140 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing masonry open duct as required.Above 35 sq. mm and upto 95 sq. mm |
| 141 | Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required.Upto 35 sq. mm (clamped with 1mm thick saddle) |
| 142 | Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm MS flat clamp) |
| 143 | Supplying and fixing cable route marker with 10 cm X 10 cm X 5 mm thick G.I. plate with inscription there on, bolted /welded to 35 mm X 35 mm X 6 mm angle iron, 60 cm long and fixing the same in ground as required. |
| 144 | Supply, installation, testing & commissioning of One Set of 1 Nos., 20 KVA UPS. Each UPS of 20 KVA should have following specifications in addition to tender requirements : (i) True online double conversions, IGBT Rectifier & inverter based UPS. (ii) Three phases Input/ three phase output (Input Line Voltage: 340 - 478 Volt, 3 phase, Output Line Voltage 400 volt, 3 phase) (iii) SMF batteries complete with MS Fabricated battery rack to accomodate the complete battery system. (iv) Suitable for 30 Min backup on Full load at 0.8 Load P.F., with required nos. of Battery with each UPS. (v) Output THD is less than 3% for full linear load & Less than 5 % for nonlinear load. (vi) Crest factor 3:1(vii) over load 125% for 10 min, 150% for 1 min and should be able to operate continuously at 115% load on bypass mode. (viii) Battery type should be Valve regulated lead-acid (VRLA). (ix) Inbuilt Delta - Star Input Isolation Transformer,parallel communication port,RS232, USB, EPO and SNMP interface, BMS interface. (x) Dust Filter at Air Inlet point are required. (xi) UPS should be provided with environment monitoring probe to measure temperature and humidity of UPS room on SNMP card software(xii) LCD Display indicating all important parameters. (xiii) UPS shall be provided with Temperature and Humidity Sensors to monitor Temperature and Humidity over LAN.(xiv) Battery open rack with top cover, battery interlinks and battery breaker. (xv) Battery to UPS cable as required should be provided with UPS systems. (xvi) UPS system shall be parallelable upto 6 units in case required in future. (xvii) Each UPS shall be compatible for working in parallel redundant mode with other.. |
| 145 | Supplying with installation testing and commissioning of Hi -- wall 5 STAR rating non ducted split type air conditioner of the following capacity with cordless remote complete with indoor and outdoor unit, copper pipe and electrical connection up to 5 m between the room unit and out door unit etc as required complete in all respect. Split Inverter 1.5 Ton capacity AC with Copper Condenser. |
| 146 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. .25 mm |
| 147 | Supplying and fixing 25 mm dia MS flexible pipe with PVC coating along with all ancillaries and accessories like coupler etc. as required. |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail