| 1 | Comprehensive maintenance of Fire Fighting system at all Bldgs/Hangers and findout the problems if any, servicing/rectifying, pressure test the same on forthnighly basis on all areaunder GE(I) (R & D ) RCI complete all as specified and directed. Note :- Required materials will be measured seperately as directed by OEM. Service report should be provided on completion |
| 2 | Supplying and fixing stainless steel single headed internal and external hydrant valve with instantaneous stainless steel couplings of 63 mm dia with cast iron wheel, ISI marked conforming to IS:5290 ( Type A ) with blank plastic cap and chain as required complete all as specified and directed |
| 3 | Supplying and fixing synthetic 63 mm dia, 15 M long synthetic hose pipe with 63 mm dia male and female stainless steel couplings duly binded with GI wire, rivets etc conforming to IS:636as required complete all as specified and directed |
| 4 | Supplying and fixing 63 mm dia stainless steel branch pipe with 20 mm ( nominal internal diameter ) size stainless steelnozzle conforming to IS:903, suitable for instantaneous connection to interconnect hose pipe coupling as required complete all as specified and directed |
| 5 | Supplying and fixing First Aid Hose Reel with MS construction spray painted in Post Office Red, conforming to IS:884 with upto date amendments, complete with the following as requiredcomplete all as specified and directed36 m long 25 mm ( nominal internal ) dia water hose thermo plastic pipe.25 mm ( nominal internal ) dia ball valve and nozzle.Drum and brackets for fixing the equipments on wall. Bracket shall be of aluminium alloy.Connections from Riser with 25 mm dia stop valve& MS pipe. |
| 6 | Supplying and fixing of hose cabinet of size 900 mm x 600 mm x 450 mm made of 3 mm thick powder coated aluminium sheet with 6 mm thick glazed glass doors including necessary locking arrangement suitable to accommodate external hydrants, 2 nos 15 m long hose pipe, 1 no branch pipe with 4 nos MS angle ( 40 x 40 x 8 ) supports grouted in floor and duly powder coated with post office red external and white internal paint complete in all respects, for external hydrant, as required complete all as specified and directed |
| 7 | Supplying and fixing of hose cabinet of size 900 mm x 600 mm x 2100 mm made of 3 mm thick powder coated aluminium sheet with 6 mm thick glazed glass doors including necessary locking arrangement suitable to accommodate external hydrants, 2 nos 15 m long hose pipe, 1 no branch pipe with 4 nos MS angle ( 40 x 40 x 8 ) supports grouted in floor and duly powder coated with post office red externa and white internal paint complete in all respects, for INTERNAL hydrant, as required complete all as specified and directed |
| 8 | Providing, laying, testing & commissioning of \"C\" class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required complete all as specified and directed |
| 9 | 80 mm dia |
| 10 | 100 mm dia |
| 11 | 150 mm dia |
| 12 | Supplying and fixing Single headed external yard hydrant valve with 1 No. 63 mm dia instantaneous FM Gunmetal/Stainless Steel coupling and cast iron wheel, ISI marked, conforming to IS 5290 (type A) with blank Gunmetal/Stainless Steel cap and chain as requiredcomplete all as specified and directed(a) Single headed Gunmetal. |
| 13 | Supplying, fixing, testing and commissioning of C.I butterfly valve of PN 1.6 rating with ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as requiredcomplete all as specified and directed |
| 14 | 80 mm dia |
| 15 | 100 mm dia |
| 16 | 150 mm dia |
| 17 | 200 mm dia |
| 18 | Supplying, fixing, testing & commissioning of double flanged sluice valve of rating PN 1.6 with non rising spindle, bronze/gun metal seat, ISI marked complete with nuts, bolts, washers, gaskets and conforming to IS 780 of following sizes as requiredcomplete all as specified and directed |
| 19 | a) 65 mm dia |
| 20 | b) 80 mm dia |
| 21 | c) 100 mm dia |
| 22 | d) 150 mm dia |
| 23 | e) 200 mm dia |
| 24 | Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts,washers etc.as required complete all as specified and directed |
| 25 | a) 80 mm dia |
| 26 | b) 100 mm dia |
| 27 | c) 125 mm dia |
| 28 | d) 150 mm dia |
| 29 | e) 200 mm dia |
| 30 | Supplying and fixing 63 mm dia, 15 m long RRL hose pipe with 63 mm dia male and female couplings duly bound with GI wire, rivets etc. conforming to IS 636 (type-A) as required complete all as specified and directeda) Gun Metal |
| 31 | Supplying and fixing first-aid Hose Reel with MS construction spray painted in post officered,conforming to IS 884 complete with the following as required complete all as specified and directed. 20 mm nominal internal dia water hose thermoplastic (Textile reinforced) type -2 as per IS: 12585.20 mm nominal internal dia gun metal globe valve & nozzle. Drum and brackets for fixing the equipmets on wall. Connections from riser with 25 mm dia stop gun metal valve & M.S. Pipe and socket.a) 30 m. |
| 32 | Supplying & fixing 63 mm dia gun metal short branch pipe with 20 mm nominal internal diameter size nozzle conforming to IS 903 suitable for instantaneous connection to interconnect hose pipe coupling as required complete all as specified and directeda) Gun metal. |
| 33 | Supplying and fixing of fire brigadeconnectionofcast iron body with gun metal male instantaneous inlet couplings complete with cap and chain as reqd. for suitable dia MS pipe connection conforming to IS 904 as requiredcomplete all as specified and directeda) 4 way - 150 mm dia M.S. Pipe. |
| 34 | Supplying and fixing air vessel made of 250 mm dia, 8 mm thick MS sheet, 1200 mm in height with air release valve on top and flanged connection to riser, drain arrangement with 25 mm dia gun metalwheelvalve with required accessories, pressure gauge and paintingwith synthetic enamel paint of approved shade as required complete all as specified and directed |
| 35 | Providing & fixing of pressure switch in M.S. pipe line including connection etc. as required complete all as specified and directed |
| 36 | Providing & fixing flow switch in following sizes M.S. pipe including connection etc as required complete all as specified and directeda)150mm dia. |
| 37 | Supply, laying, testing and commissioning of centrifugally Cast Ductile Iron pipes conforming to IS 8329:2000 class K9, with Cement Mortar Lining (CML) inside as per IS 455:2989 along with Bituminous coating outside suitable for socket and spigot type (DISS) joints for following sizes and testing the joints for leakage (if any) and making good hydrant system complete all as specified and directed(a) 150 mm Dia. |
| 38 | M & L for Servicing , testing of electric driven pressurisation pump suitable forautomatic operation and consisting of following, complete in all respects, as requiredon all areaunder GE(I) (R & D ) RCI (Jockey Pump, Deisel Pump & Electric driven main pump on Fortrh Nightly basisand bronze impeller with stainless steel shaft, mechanical seal conforming to IS : 1520., coupling, coupling guard,etc complete all as required at sitecomplete all as specifiedand direcetd |
| 39 | Repair of valve chamber including necessary PCC and plastering , fixing of hold fast hinged andangle frame with MS sheet cover 3mm thick of valve pit of size 900mm x900mm x 500mm.Complete all as specified and directed. |
| 40 | Supply and fix MCCB 4 Pole, 415 V, Adjustable type, 400 Amps,36 KAof any description complete all as specified and directed by Engineer-in-Charge. |
| 41 | Supply and fix MCCB 4 Pole, 415 V, Adjustable type, 250 Amps,36 KAof any description complete all as specified and directed by Engineer-in-Charge. |
| 42 | Supply and fix MCCB 4 Pole, 415 V, Adjustable type, 200 Amps,36 KAof any description complete all as specified and directed by Engineer-in-Charge. |
| 43 | Supply and fix MCCB 4 Pole, 415 V, Adjustable type, 160 Amps,16 KAof any description complete all as specified and directed by Engineer-in-Charge. |
| 44 | Supply and fix MCCB 4 Pole, 415 V, Adjustable type, 125 Amps,16 KAof any description complete all as specified and directed by Engineer-in-Charge. |
| 45 | Supply and fix MCCB 4 Pole, 415 V, Adjustable type, 63 Amps,16 KAof any description complete all as specified and directed by Engineer-in-Charge. |
| 46 | Excavation in trenches not exceeding 1.5 Mtr wide and not exceeding 1.5 mtr depth for laying cable at andgetting out insoft/loosesoil all as specified and directed. |
| 47 | Returning, filling in soil including spreading, levelling, watering and well ramming in layers, not exceeding 25 cm thick all as specified and directed |
| 48 | Removing surplus soil to a distance not exceeding 50 Mtr and deposited at a level not exceeding 1.5 mtr above from the starting point all as specified |
| 49 | M & L for DOL starterupto 50 HP, 50 Hz, 415 Volts complete all as required at site including cutting in case and fixing, testing complete all asspecifiedand directed |
| 50 | Comprehensive maintenance of Fire Alaram system at all Bldgs/Hangers and findout the problems if any, servicing/rectifying the same on monthly basis on all areaunder GE(I) (R & D ) RCI complete all as specified and directed. Note :- Required materials will be measured seperately as directed by OEM. Service report should be provided on completion. All makes as requied at site confirming to meet the sucessfully run the sytem |
| 51 | Supply,Repair, Testing and commissioning of the following number of Loops Microprocessor based addressable type (EN / UL approved) Fire alarm control panel with Zonal Indications, supervised inputs, supervised and non-supervised outputs,Zener barriers, two way media converter / Signal booster for in / out network connectivity with OF cable and with battery Powerpack as per specifications the panel complete all as specified and directed. |
| 52 | a) 1 - Loop |
| 53 | b) 2-Loop |
| 54 | c) 4-Loop |
| 55 | Supply installation, testing and commissioning of analog addressable type multi sensor (smoke/ Heat) photo electric detectors with base and LED indication lamp along with all fixing accessoriescomplete all as specified and directed. |
| 56 | Supply, installation, testing and commissioning of Single ended reflector type addressable Beamsmoke detector with all required accessories etc complete all as specified and directed. |
| 57 | Supply installation, testing and commissioning of reponse indicators with LED indication lamp along with all fixing accessoriescomplete all as specified and directed. |
| 58 | Supply, Installation, Testing and commissioning of anologue addressable loop sounders along with all fixing accessories complete all as specified and directed. |
| 59 | Supply, Installation, Testing and commissioning of fault isolators along with all fixing accessories complete all as specified and directed. |
| 60 | Supply,Installation,Testing and commissioning of anologue addressable type monitor module along with all fixing accessories complete all as specified and directed. |
| 61 | Supply,Installation,Testing and commissioning ofaddressable control module along with all fixing accessoriescomplete all as specified and directed. |
| 62 | Supply, Installation,Testing and commissioning of anologue addressable ordinary Manual call pointwith push type along with all fixing accessories complete all as specified and directed. |
| 63 | Supply,laying,testing of twisted pair1.5sq mm shielded FR insulated copper conductor flexible wire in existing PVC conduit complete all as specified and directed. |
| 64 | Supply& Fixing of data outset (RJ45) with anodised GI box with frontplate etc complete all as specified and directed. |
| 65 | S & F 2.5 KM range siren with weather proof motor complete all as specified and directed. |
| 66 | S & F Copper strip 50 x 5 Sqmm i.e earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing, saddles, clamps etc including taking down old onecomplete all as specified and directed. |
| 67 | S & F Copper strip 25 x 4 Sqmm i.e earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing, saddles, clamps etc including taking down old onecomplete all as specified and directed. |
| 68 | Supply, lating of 3 core 2.5 Sqmm copper cable including suitable conduit as and where requiredcomplete all as specified and directed. |
| 69 | M & L for earthingcomplete with galvanized steel earth plate electrode60 x 60cm x 6 mm thick burried directly in ground vertically to a depth not less than 2.25 mtr deep below GL with top edge of the plate not less than 1.5 mtr below normal GL and connected to earth plate surrounded by 15 cm thick packed layers of charcoal dust and common salt and connected to earth lead GI wire 32 x 6 mm by means of bolts, nuts, check nuts and washers of galvd iron or steel and thimbles and other end of the earth wire connected to DB and protected by galvd iron or steel pipe light grade 15 mm bore and water pipe 20mm bore GI medium grade with funnel and wire mesh, including all necessary excavation and earth work PCC chamber in cement concrete 1:3:6 type C-2 and RCC cover and all as shown in electrical plate No 3 of MES schedule Pt I of2009. (including taking down of old existing earthing)complete all as specified and directed. |
| 70 | M&L for sub main wiring surface/recessed as required with two single core 2.5 sqmm PVC insulated and unsheathed copper conductor, multistranded 1100 volts grade through and including non metalic rigid PVC conduit including 6 sqmm copper conductor multistranded PVC insulated and unsheathed wire as earth continuity conductor along the wiring and connected to the common earth dolly complete including removing the existing U/S sub main wiring and making good the disturbed surface to match with the existing all as specified and directed. |
| 71 | All as per ItemNo 50 but 2 x 4 sqmm and 1x 4 Sqmm as earth wire |
| 72 | M&L for sub main wiring surface/recessed as required with four single core 6 sqmm PVC insulated and unsheathed copper conductor, multistranded 1100 volts grade through and including non metalic rigid PVC conduit including2x6 sqmm copper conductor multistranded PVC insulated and unsheathed wire as earth continuity conductor along the wiring and connected to the common earth dolly complete including removing the existing U/S sub main wiring and making good the disturbed surface to match with the existing all as specified and directed. |
| 73 | All as per ItemNo 20 but 4 x 10 sqmm and 2x 10 Sqmm as earth wire |
| 74 | M & L for earthingcomplete with copper plate600 x 600 x 6 mm thick burried directly in ground vertically to a depth not less than 2.25 mtr deep below GL with top edge of the plate not less than 1.5 mtr below normal GL and connected to earth plate surrounded by 15 cm thick packed layers of charcoal dust and common salt and connected to earth lead GI wire 25x 3 mm by means of bolts, nuts, check nuts and washers of galvd iron or steel and thimbles and other end of the earth wire connected to DB and protected by galvd iron or steel pipe light grade 15 mm bore and water pipe 20mm bore GI medium grade with funnel and wire mesh, including all necessary excavation and earth work PCC chamber in cement concrete 1:3:6 type C-2 and RCC cover and all as shown in electrical plate No 3 of MES schedule Pt I of2009. (including taking down of old existing earthing)complete all as specified and directed. |
| 75 | Supply and fixing aluminum strip 25 x 3 mm complete with saddles and fixing screws for roof / down conductor on porcelain/epoxy spacer insulator or fixed in GI Pipe all as specified and as directed. |
| 76 | S & F in repairs sealed lead acid battery 12 volts 7 AH complete all as specidied and directed. |
| 77 | S&F in repairs, Display cardmain Fire Alarm control panel and Repeter panel control panel with LCD display, event storage with real time clock communication for network form C relay for fire extensive built in transient protection lamp test facility common fire, supervisory, fault LED indication including testing complete all as specified and as directed. |
| 78 | S&F in repairs, PCBcardmain Fire Alarm control panel amd Repeter Panel control panel with Loop , event storage with real time clock communication for network form C relay for fire extensive built in transient protection lamp test facility common fire, supervisory, fault LED indication including testing complete all as specified and as directed. |
| 79 | Dismantling and Reprogramming Single loop Fire Alarm main panel/ repeater panel board of any make for correct indication of sensors, detectors as per present precise locations as per manufacturer\"s instructions convenient windows programming software, changing of detector/sensor location, name, address of room, testing for exact fault locations and reconnecting to entire satisfaction of Engineer in Charge complete all as directed. |
| 80 | All as per item No 59 above for Two loop Fire Alarm main panel board |