| 1 | Scraping of old white or colour wash including disposal of refuse as directed y engineer uncharge Sl No. 708 |
| 2 | Dismantling existing plaster including disposal refuse as directed by engineer incharge with in distance of 60 m Sl No-706 |
| 3 | Including base concrete and including base con. And including stacking of dismanteled material as directed by the engg. In charge |
| 4 | Dismenteling of reinfored cement concrete or reinforce brick work including stacking of dismanteled material as directed by the engg. In charge within a distance of 60 m |
| 5 | Racking out joint of brick work in cement or lime, mortar to a depth of 1 cm including disposal of refuse as directed by engg. Incharge within distance of 60 m Sl No-707 |
| 6 | First class brick work in 1:4 cement/ coarse sand mortar in super structure including cutting and moudling of bricks as required and including honey comb brick work thickness of wall one brick thick |
| 7 | As in item no. 309 above but for wall of half thick (115 mm) cement mortar 1:3 (1 cement :3 coarse sand) |
| 8 | Extra for providing and placing in position 2 Nos. 6 mm dia M.S bars at every third course of half brick masonry |
| 9 | Cement cocrete with 20 mm approved stone ballast, approved coarse sand in proportion of 1:1.5:3 including supply of all materials, labour and T & P etc. required for proper comletion of work (CC above roof) |
| 10 | Supply and fixing of murga jali for roof treatment MR |
| 11 | Providing wood work in frames of door windows, clerestory windows and other frames, wrought framedand fixed in position with hold fast lugs or with dash fasteners of required dia and length (hold fast lugs or dash fastner shall be paid for separatly ) . Sal wood |
| 12 | Providing and fixing panelled and glazed shutters for doors windows and clerestory windows, fixing with butt hinges of required size with necessary screws, excluding panelling which will be paid for separatly, all complete as per direction of ingg incharge(note- butt hinges and necessary scruws shall be paid separetly) second class teak wood 25 mm thick shutters |
| 13 | Providing and fixing ISI marked flush door shutters confirming to IS:2202 (part 1) non decorative type, core of block board constructions with frame of first class hard wood and well mached commercial three ply veneering with vertical grain or cross brand and face veneers on both face of shutters: 35 mm thick including ISI marked stainless steel butt hinges with necessary screws (32 mm thick) |
| 14 | Providing and fixing fly proof wire gauge shutters using galvanized MS wire gauge of average width of aperture 1.4 mm in both directions with wire of dia 0.63 mm , doors, windows and clerestory windows with hinges and necessary screws: second class teak wood beading 62x 19 mm |
| 15 | Provind and fixing ISI marked oxidised M.S tower bolts with nuts and screws etc. complete (1) 250x 10 mm |
| 16 | (2) 200x10 mm |
| 17 | (3) 150x 10 mm |
| 18 | Providing and fixing aluminium handles ISI marked anodised 125 mm |
| 19 | Providing and fixing ISI marked oxidised M.S sliding door bolts with nuts and screws etc complete (1) 300x16 mm |
| 20 | (2) 250x16 mm |
| 21 | Providing and fixing glass panes ith putty and glazing clips in stell door,windos,clerestory windows ,all complete 4.0 thick mm glass panes |
| 22 | Providing and fixing aluminium work for doors ,windows ventilator and partition with extruded builtup standard tubular section /appropriat Zsection and other section of approved make confirming ti Is:33 and IS 285 fixing with dash fasteners of required dia and sie including with necessory filling up the gaps of junction ,i.e. at top,bottom and sides with required EPDM rubber/neoprene gasket etc.Aluminium sections shall be smoooth ,rust free ,traight ,miltered and jointed mechanically wherever required including cleat angle,aluminium snap beading for glazing /panelling ,C.P. brass/stainless screws ,all complete as per architectural drawing and the direction of I/E (Glazing ,panelling and dash fasteners to be paid sperately )for fixed portion. |
| 23 | As item no.17 for shutters of doors,windows /a7 ventilator including providing and fixing hinges/pivots and making provision of fixing and fittings Wherever required including of the cost of EPdmRuber /neoprene gsket required (fitings shall be paid for seperatel) |
| 24 | providing and laying vertified floor tles in different tiles(thickness to be specified by the manufacturer)with water apsorption lesss than 0.08% and conforming to IS: 15622 ,of approved make , in all color and shades ,laid on 20mm thick cement moratar 1:4(1 cement :4 coarse sand ) ,jointing with grey cement slurry @3.3 kb/sqm including gouting the joints with cement and matching pigments etc. The tile must be cut with zero chipping diamond cuttter only,laying of tile will be done with notch trowel ,piler,wedge,clips of required thickness,levelling system and rubber mallet for placing the tiles gently and asily .Size of tile 600 x 600 mm |
| 25 | Supply and fixing mm china white glazed in flooring or skirting ,Dado laid with 1:3 cement and approved coarse sand mortar finished with white cement slurry jointing and polishing complete including supply of all material ,labour and T&P etc. Size of Tile 600X600 mm. |
| 26 | laying of 25mm thick of KOTA stone of size 45X45 cm and above flooring over previously prepared base with 2cm thick 1:3 cement and sand mortar including filling of joints with cement mixed with pigment required for matching the shade of floore as per direction of E/I including cutting polishing with wax polish including supply of all materials t&p etc required for proper completion of work.25mm thick |
| 27 | Providing gola 75X75 mm in cement concrete 1:2:4 (1 cement:2sand:4stone aggregate 10mm and down grade) including finishing with cement mortar 1:3(1 cement :3 sand ) as per standard design :75X75mm deep chase. |
| 28 | 12mm thick cement plaster with 1:5 cement and coarse sand mortar (1 cement:5 coarse sand) |
| 29 | Ceiling plaster with 1:3 cement and fine sand,As per item S.No 587 +587(1:3 (1cement :5 coarse sand)). |
| 30 | plaster on rough side of single or half brick wall of mix 1:5(1 cement :5 coarse sand ) |
| 31 | Providing and applying POP/putty of average thickness 2mm ,of approvd brand and manufacturer ,over the plastered wall surface to prepare the surface even and smooth complete. |
| 32 | Distempering with oil bound distemper of approved brand nd manufacture and of required shade on undercoated wall surface to give an even shade over and including a priming coat with cement primr of approved brand and manufacture such as berger J&N shalimar ,Asian paint after thoroughly brushng the surface free from morter droping and other foreign matter and also preparing the surface even the plaster of approved synthetic material and sand prepared smooth including cost of material (3 coat on previously old distempered surface) |
| 33 | Painting on ood or steel and other metal surface with superioir synthetic enamel standred make brushing to give an even shade and finish including cleaning the surface of all dust &other foreign matter sand papering and stripping including cost of all material ,labour,T&Petc. i)for steel surface |
| 34 | ii)for wood surface |
| 35 | Providing and laying \"brick Coba\"12mm thick laid with M-150 class brick coba 7.50cm thick with gap of 15mm to each other ,over 20mmm thick base of cement mortar 1:4 cement and coarse sand mixed with water profing compound speeding cement slurry mixed with acreliccement concrete water proofing compound filled gaps of coba and topof coba mortar mixed with water proofing compound in 1:4cement and coarse sand mortar finishsmooth &top mashed false square 30cmX30cm and side wall parapet shall be mono tythic plaster wall upto 30cm and higher and junction and corner shall be rounded by brick ballast cement and coarse sand masonary coba with top finished plaser mixed wth acetic water proofing compound @2%by weight &including supply of all material ,labour,T&P etc complete for poper completio of work. |
| 36 | Supplying and fixig suitable size GI box with modular plate and covers in front on surface or in recess,including providing and fixing 3pin 5/6 Amodular socket outlet and 5/6 Amodular switch ,connections etc.as required. |
| 37 | Wiring for light pont/fan poin/exhaust fan point all bell point with 1.5sq.mm FRLS PVC insulated copper conductor single core cabe in surface recessed medium class PVC conduit ,with modular swich,modular plate ,suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc.as required |
| 38 | Insulated copper conductor single core cable in surface/recessed medium class PVC conduit alngwith 1no.4sq,mm.FRLS /HFFRpvc insulated copper conducter singl core cable for loop earthing as required |
| 39 | S/F 4 way double door MCB distribution board on surfaces/recess without Mcb complete I all respect as directed at site by Engineer -in-charge. |
| 40 | Supply and fixing 05 A to 32 A rating 240/415 v , 10 KA in existing MCB DB complete with connection, testing and commissioning etc. |
| 41 | S/f of 40 amp DP CB (10KA) |
| 42 | Supply and fixing of LED Tube light with battte suitable for up to 1X 22 watt LED tube light fitting including tube on surface complete in all respect CAT-AA |
| 43 | Supply and fixing of PVC batten /angle holder complete in all respect |
| 44 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connetions but excluding modular plate etc. as required 6 Pin 15/16 A socket outlet |
| 45 | Supplying installation testing & commissioning of LED recessed/ surface down lighter (round/ square/ rectangular) COB type of following body material & construction as per IS: 10322 with driver as per the requirment 18 Watt |
| 46 | Providing and fixing water closet squatting pan (indian type WC pan) with 100 mm sand cast iron P or S trap, 10 ltr low level white PVC flushing cistern with manually controlled device (handle lever) conforming to IS: 7231 with all fitting and fixtures completed including cutting and making good the walls and floors wherever required white vitreous china orissa pattern WC pan of size 580x440 mm with integral type foot rests |
| 47 | S/F of china glazed hand wash basin with padastal including all fixtures complete |
| 48 | Providing and fixing white china pedastal type water close (european type WC pan) with seat and lid with 10 ltr low level white PVC flushing cistern with manually controlled device (handle lever) conforming to IS: 7231 with all fitting and fixtures completed including cutting and making good the walls and floors wherever |
| 49 | Providing and fixing flexibl PVC waste pipe for sink or wash basin including PVC waste fittings complete flexible pipe (a) 32 mm dia |
| 50 | (b) 40 mm dia |
| 51 | Providing and fixing 600x450 mm beveled edge mirrir of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with CP brass screws and washers complete |
| 52 | Providing and fixing on wall face unplasticised rigid PVC rain water pipes conforming to IS: 13592 type A including jointing with seal ring conforming to IS: 5382 leaving 10 mm gap for thermal expansion (1) single socketed pipes (a) 110 mm diameter |
| 53 | Providing and fixing in floor and wall face ringfit UPVC ASTRAL conventional system for soil and waste water pipes conforming to drain master swr type B including jointing with seal ring (1) double socketed pipes (a) 110 mm dia PVC pipe |
| 54 | (b) 90 mm dia PVC pipe |
| 55 | Providing and fixing UPVC floor trap of self cleansing design with CP jali complete in all respects (make : supreme/ Finolex/ Prince) P- Trap type floor trap 110x90 mm |
| 56 | Providing and fixing on wall face unplasicised PVC moulded fittings/ accessories for unplasticised rigid PVC pipes including jointing with seal ring leaving 10 mm gap for thermal expansion (make : supreme/ finolex/Prince) door tee 110x110x110 mm |
| 57 | 110x110x90 mm |
| 58 | Bend 110 mm |
| 59 | Providing and fixing chlorinated polyvinyl chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of engg. in charge Concealed work including cutting chases and making good the walls etc. (a) 25 mm dia nominal outer dia pipes |
| 60 | Providing and fixing CP brass long nose bib cock of apprived quality conforming to IS standards and weighing not less than 690 gms. 15 mm nomonal bore |
| 61 | Providing and fixing CP brass angle valve for basin mixer and gyser points of approved quality conforming to IS 8931 15 mm nomonal bore |
| 62 | Clearing and refixing of water storage tank MR |
| 63 | S/f of CP pillor cock 15mm dia |
| 64 | S/f of PVC connection 45 cm long |
| 65 | S/f of 15 mm dia cp nipple |
| 66 | Supply and fixing of SS towel rail |
| 67 | s/f of pvc cistem low level MR |
| 68 | Febrication of shade with angle and flat including fiber sheet iron MR |
| 69 | S/f of fibre sheet |
| 70 | Repair door MR |
| 71 | Repair window MR |
| 72 | Repair of light switch board necessary switches, wire etc. complete MR |
| 73 | Providing and fixing pof pvc wall panneling at all hight including profile & accessories T&P all complete as perdrawing, specification and direction of engineer incharge NSI |
| 74 | Providing and fixing of pvc false ceilling includingprofile and accessories T& P GI main runner 15x32 mm of 3000mm length 0.33 mm thick including 10% wastege gi cross tee 15x32 mm of 1200 mm length 0.33 thick, GI cross tee 15x32 mm of 600 mm length 0.33 mm thick galavanised perimeter wall angle size 24x24x.40 long including 10% wastage , galavanised MS L shape leavel adjuster of side 85x25x2 mm galavanised MS 8 mm outer diameter M-6 dash fastner 500 mm long, 40 mm long SS screws with plastic rawl plug all. complete |
| 75 | Cleaning of office building roof & periferial area of campus |
| 76 | Misclanious expencess for electrical work |
| 77 | Misclanious expencess for plumbing & sainitary work |
| 78 | Providing and placing on terrace (at all floor level) polethene water storage tank complete Please Enable Macros to View BoQ information |