| 1 | Excavating over areas, n exc 1.5 m deep and getting out in soft/soft soil etc complete all as specified and directed. |
| 2 | Rolling and consolidation formation of surface of road in cutting/filling with power road roller exc 8 to 12 tonne including filling depression which occur during the rolling acomplete all as specified and directed. |
| 3 | Granular sub base100mm thick with Shingle or gravel spread thickness, spread, rolled and consolidated to gradient and camber for road side required complete all as specified and directed. |
| 4 | M&L for 150mmCement concrete type D- 2, 1:4:8 (40mm graded aggregate) complete all as specified and directed. |
| 5 | M&L for 150mm WBM in two layers each layer 7.5cm thick (compacted thickness), with granitr or basalt coarse aggregates of grading 2 (63 to 40mm size) or of grading 3 (50 to 20mm size), spread, rolled and consolidated to gradient and camber with power road roller exc 8 to 12 tonsrequired and complete all as specified and directed. |
| 6 | M&L for sett flooring with Stone sett flooring with stone setts of size 200 to 250mm long, 150 to 200mm wide and 150mm deep and sides dressed; bedded in cement mortar 1:3 20mm thick; grouted in cement mortar 1:2 with an admixture of metallic floor hardner 5% by weight of cement and struck flush complete all as specified and directed. |
| 7 | M&L for Edge stones to flooring with stone setts of size 250 to 300mm long x l50 to 200mm wide, and 450mm deep and sides dressed; bedded in cement mortar 1:3, joints 20mm thick; grouted in cement mortar 1:2 with an admixture of metallic floor hardner 5% by weight of cement and struck flush complete all as specified and directed. |
| 8 | M&Lof cement concrete type B1 1:2:4 (40 mm graded aggregate) complete all as specified and directed. |
| 9 | Excavation in trenches, not exceeding 1.5 meter wide and not exceeding 1.5 meter in depth for foundation etc or for shafts, wells, cesspits, manholes, pier holes etc not exceeding 10 Sqm area on plan and not exceeding 1.5 meter in depth and getting out in soft/loose soil complete all as specified and directed. |
| 10 | M&L Hard core of gauge n exc 63mm, deposited, spread and levelled in layers n exc 10cm thick (in tranches and surface), watered and rammed to a true surface with broken stone or boulders complete all as specified and directed. |
| 11 | M&L for PCC 1:4:8 type D2 (40 mm graded aggregate ) in foundations, filling and mass concrete sub base complete complete all as specified and directed. |
| 12 | Removing excavated material n.exc 50 m and depositing where directed at a level n.exc 1.5 m above the starting point complete all as specified and directed. |
| 13 | Returning, filling in, including spreading, levelling, watering and well ramming in layers n.exc 25 cm in hard/dense soil complete all as specified and directed. |
| 14 | M&L RCC ofNominalMix of 1:1.5:3 as in Foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete complete all as specified and directed. |
| 15 | M&L RCC ofNominalMix of 1:1.5:3 as in Columns, pillars, piers, posts and struts complete all as specified and directed. |
| 16 | M&L for Formwork to sides of pillars, posts, struts, piers, columns and stanchions complete all as specified and directed. |
| 17 | M&L Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter complete all as specified and directed. |
| 18 | M&L Rendering 10 mm thick on fair faces of brickwork or concrete surfaces finished even and smooth without using extra cement on walls in CM 1:6 complete all as specified and directed. |
| 19 | M&L two coat of cement base paint on walls incl preperation of newly untreated surface with a coat of cement wash with portland cement complete all as specified and directed. |
| 20 | M&L Mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed. |
| 21 | S&F TMT steel bars 5mm dia and over upto and including 10mm dia in stirrups, or bars for slab also, spacers and binders binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed. |
| 22 | S&F Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed. |
| 23 | M & L Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc Fe-410-W(gde-E-250) quality B complete all as specified and directed. |
| 24 | S&Fbase plates (plain or chequered) channels,lug angle,square cut or notched (ordinary and counter sunk) forming holes, without any attachmentincluding welding etc all as spfd and directed by EIC.Fe-410-W(gde-E-250) quality B complete all as specified and directed. |
| 25 | S&F mild steelscrew bolts (Machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, length of bolt exc 5cm but nexc 10cm long and diameter of neck in mm 11 to 15 complete all as specified and directed. |
| 26 | M & L Painting steel surface of any description over 10 cm width and girth including preparation, primer with red oxide and two coats of synthetic enamel paints complete all as specified and directed. |
| 27 | M&L 150mm thickHard core of gauge n exc 63mm,of broken stone aggregate deposited, spread and levelled in layers n exc 15cm thick (in tranches and surface), watered and rammed and compected with 8 to 10tonns power roller complete all as specified and directed. |
| 28 | M&L for Providing and laying 80mm thick factory made chamfered edge cement oncretepaver block of M-30 grade with approvedcolour, design & pattern as in footpath, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of coarse sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with fine sand and cutting of paver block as per required size and pattern, finishing and sweeping extra sand complete all as specified and directed. |
| 29 | M&L for Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, ointed with cement mortar 1:3 (1 cement: 3 coarse sand), ncluding making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5 mm), includingmaking drainage opening wherever equired complete all as specified and directed. |
| 30 | M&L for applying two coats of synthetc enamal paint after preperation of new surface complete all as specified and directed. |
| 31 | Chequered cement concrete tiles with grey cement and pigments 200mm x 200mm x 25/ 30cm X30cm X25mm thick, set in 15mm thick CM of (1:6), jointed and pointed in neat cement slurry in floors/paths complete all as specified and directed. |
| 32 | Material and labour for point wiring with 1.5 sqmm (22/.3mm) PVC insulated and unsheathed FRLS single core multistranded copper conductor for one light point in and including PVC rigid non metallic surface/concealed conduit 19/20 mm dia medium duty, ISI marked to beterminated & including pressed modular steel boxes & cover plate of module as required on site.including 1.5 sqmm (22/.3mm) PVC insulated and unsheathed FRLS single core multisrtanedcopper earthcontinuity conductor controlled by one switchand/or one regulator complete including repairing the surfaces in CM 1:3 and finishingthe surface as per exisitng treatment complete all as specified and directed. |
| 33 | Description all as per item No 32.00 (here-in-before) but One three pin 5 Amp socket outlet point on independent board controlled by one nos, one way switch on independent board complete all as specified and directed. |
| 34 | Description all as per item No 32.00 (here-in-before) butOne three pin 5 Amp socket outlet point on same board controlled by one nos, one way switch on same board complete all as specified and directed. |
| 35 | Description all as per item No32.00 above but point wiring with 2.5 sq mm single core FRLS cables and earth continuity wire with 2.5 Sq mm single core cable for one 3 pin 15 Amps socket out let point controlled by one nos, one way switch on independent board complete all as specified and directed. |
| 36 | S&F Modular switch 1 way 6A 1 module Single pole, one way, 230 volts complete all as specified and directed. |
| 37 | S&F Modular switch 1 way 16A 1 module complete all as specified and directed. |
| 38 | S&F Modular socket 6A -2/3 pin combined 2 module type 230 volts AC complete all as specified and directed. |
| 39 | S&F Modular socket 6A/16A -2/3 pin combined 2 module type AC complete all as specified and directed. |
| 40 | S&F LED high bay light (lens type) 80 watt, input voltage 90v-300v, power factor >0.98, lumen efficiency 120 lumen/w.surge protection >5.0 to 10 kv, beam angle 60 degree IP standard IP 65, made of diecasting aluminium & tuffen glass complete all as specified and directed. Make ; OASIS |
| 41 | S & F for Energy saving new generation environmental friendly long life versatile pressure die cast aluminium IP 66 for security light fitting luminaire with high power LEDs as light source not less than 120 lumen/watt and electronic driver of capacity 25/35 watts with pre wired andnecessary mounting arrangements and provision of 1.5 sq mm three core copper conductor cable multi stranded from ceiling rose to light fitting including 40 mm dia GI pipe medium grade bracket 1.5 mtr long bend to required shape with clamps, nut, bolts complete all as specified and directed. |
| 42 | S&F Sheet metal enclosure distribution board SP&N,8 way, double door powder coated, protection class IP-42 suitable for mounting MCB DBs confirming to IS-13032, IS-8632, BS5484 with min 200 Amp rating copper bus bar complete all as specified and directed . |
| 43 | Supply and fixing240V, 10 KA \"B\" curve miniature circut breaker (MCB) of single poles and current carrying capacity 5 to 32 AMP, in the MCB DB complete with connection teesting and commissioning complete all as specified and directed. |
| 44 | Supply and fixing MCBs SPN 32Amps,240 volts, 10 KA rupturing capacity, IS-8828 marked, of the under mentioned type and rating and fixing in DBs (DBs Catered separately in this schedule) complete all as specified and directed. Note:Make of the MCB should be the same as that of DB |
| 45 | Supply and laying or fixing or passing through pipe, 1100 volts grade heavy duty cable with PVC insulated aluminium conductor served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall PVC sheathed 16 Sq.mm nominal cross section, 2 Core in service connections complete all as specified and directed. |
| 46 | M & L for earthing complete with galvanized steel earth plate electrode 60 cm x 60 cm x 6 mm thick buried directly in ground vertically (earth pit not less than 2.25m deep below ground level) with top edge of the plate not less than 1.50 mtr deep below normal ground level, connecting to GI earth wire 4mm dia by means of bolts, nuts, check nuts, and washers of galvanized iron or steel including 15 mm dia. medium grade protection pipe for earth lead complete with charcoal and common salt including watering arrangement with galvanized iron pipe light grade 20 mm dia, PCC Chamber, CI frame and cover, MS funnel with wire mesh all as shown in electrical plate no 3 of SSR part I including excavation and earthwork in any type ofsoil/strata and testing on completion. Note:- GI earth wire 4 mm dia and 15 mm dia protection pipe upto 7.5 mtr from earth plate is deemed to be included in rate quoted. |