Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | Taking down cement plaster on bricks or stone wall/ decayed surfaces of concrete from roof projection or RCC Chajjas etc. including racking out joints, hacking for key, scrubbing down with water, etc including removing the waste out of defence land complete all as specified and as directed. |
| 2 | M&L rendering 10 mm thick on fair faces of brick work or concrete surfaces in CM 1:6 finished even and smooth without using extra cement completeall as specified and as directed. |
| 3 | M&L Rendering 15 mm thickonfair faces of brick/concrete surfaces in cement plaster 1:4 finished even and smooth without using extra cement, using water proofing compoundmix as per manufacturer detail,completeall as specified and as directed. |
| 4 | M&L Rendering 5 mm thick on concrete surfaces in CM 1:3 finished on even and smoothwithout using extra cement as in ceiling, Chajja etc completeall as specified and as directed. |
| 5 | Material & Labour for RCC chajja/fascia/parapet repair by using following steps :-(a) Removal of existing concrete along with loose damaged and cracked concrete/cover concrete from chajjas etc, exposing corroded steel reinforcements upto a depth of 10mm minimum behind the reinforcement by chipping/hacking with chisel and hammer or by mechanical means like chisel hammer, pneumatic chippers including high pressure water jetting to chipped concrete and reinforcement all as directed by Engineer-in-charge. Hard concrete shall not be removed. However if the rebar is corroded, concrete around it shall be removed.(b)Cleaning the surface of reinforcement bars from dust by using wire brushes and dry cloth and applying FOSROC Rebakleens RR- Rust Remover or equivalentusing small brush and allow to react it for 16-24 hrs. (c) Providing and applying two coats of Fosroc Nitozinc Primer - two component, zinc rich epoxy, anti-corrosive protective coating or equivalentby brushes to the exposed and cleaned rebars with an interval of 45minutes to 1 hour @ 40microns DFT / coat and allowed to completely dry for 24 hours all as directed by Engr-in-Charge. |
| 6 | Taking down chowkats or frames n. exc. 1.5 sqm each but with shutter without taking off shutters from the frame completeall as specified and as directed. |
| 7 | Taking down chowkats or frames exc. 1.5 sqm & n.exc. 4 sqm each but with shutter without taking off shutters from the frame completeall as specified and as directed. |
| 8 | Pressed steel frame for door with one or more rebates including necessary lugs, fixing lugs hinges, lock strike plate etc. of size 125mm x 60 mm and made of 1.25mm thick MS sheet, complete all as specified and directed including necessary welding complete and including medium weight 03 Nos of MS butt hinges of size 75mm / 100mm / 125mm and 01 No 50mm Size of medium weight MS butt hingecompleteall as specified and as directed. |
| 9 | Pressed steel frame for door with one or more rebates including necessary lugs, fixing lugs hinges, lock strike plate etc. of size 105mm x 60 mm and made of 1.25mm thick MS sheet, complete all as specified and directed including necessary welding complete and including medium weight 03 Nos of MS butt hinges of size 75mm / 100mm / 125mm and 01 No 50mm Size of medium weight MS butt hingecompleteall as specified and as directed. |
| 10 | M&L PCC (1:3:6) type C-2 (40 mm graded aggregate) filling back of chowkats completeall as specified and as directed. |
| 11 | M&L 35 mm thick Flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides with both face is covered with deco rative face veneer with lipping/frame to matchcompleteall as specified and as directed. |
| 12 | S&F 35mm thick 2nd class hard wood Glazed and skeleton shutters open rebated & prepare to receive glass, gauge etc (without sash bars /edges of framing plain chamfered or rounded, fitted with cut and mitred beds for securingglass etc) size of members of shutterscompleteall as specified and as directed. |
| 13 | S&F Framed brackets of angles or tees with web and flanges cut to shape for cooler stand, drilled and countersunk for screw, including bending and welding angles, as necessary, gusset plates, riveting, etc. not exc 10 kg each brackets, conforming to Fe.290.Gde-E-165 completeall as specified and as directed. |
| 14 | Mild steel framed work as in doors ( as in chowkats)or gates of angle or other section with guest plates rails, braces rail etc exculsive of steel sheeting or other covering hanging also fastening and fixingcomplete confirming to Fe-410- W(Gde- E-250) quality- B including shop coat of red oxide including preparation of surface before fixing completeall as specified and as directed. |
| 15 | S&F factory made solid PVC moulded door shutter with wood free EPS 28 to 30mm thick (Stile) withflushpanelwith 2mm thick moulded PVC sheet on the front face & 2mm plain colour PVC sheet on back facecompleteall as specified and as directed. |
| 16 | Steel ventilator with top hung shutter including hinges, steel peg stay, lugs as in hold fast with locking arrangements, completeall as specified and as directed. |
| 17 | Steel windows with side hung double shutters (window consisting of two shutters out side and two shutters of similar dimension inside of single MS Frame) box type hinges with steel handle of 100mm and steel peg stay, complete with glazing bars, and including MS guard bars and grills made out of 10mm MS square bar (Grill and guard bars shall be provided as per directions of Engr-in- Charge during execution of work) dovetailed or weldedcompleteall as specified and as directed. |
| 18 | S&F Galvanized mild steel wire cloth 0.45 nominal dia of wire and average width of aperture 1.18mm and fixed with tinned tank or galvanized wire staplecompleteall as specified and as directed. |
| 19 | Sheet glass, ordinary quality, 3mm thick and glazed with oil putty or wooden beads, in square n exc. 0.5 Sq m each pane,completeall as specified and as directed. |
| 20 | 3mm thick figured glass, pin head type and glazing with oil putty or wooden beads in square not exc 0.5 sqm each completeall as specified and as directed. |
| 21 | S&F Aluminium alloy, anodised, sliding door bolt with hasp, staple (both type) 300mm longh, and fixing clips of sheet cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixedcompleteall as specified and as directed. |
| 22 | S&F Aluminium anodised 150mm long barrel tower bolt of extruded section and fixing completeall as specified and as directed. |
| 23 | S&F Aluminium handles cast type anodised 150mmcompleteall as specified and as directed. |
| 24 | S&F Butt hinges 100mm medium weightstainless steelcompleteall as specified and as directed. |
| 25 | S&F Aluminium anodized barrel tower bolt of extruded section and fixed complete of size 125 mm longcompleteall as specified and as directed. |
| 26 | S&F Aluminium handle cast type anodized of size 125mmcompleteall as specified and as directed. |
| 27 | S&F Floor door stopper of aluminium alloy body and tongue, anodised with hard drawn steel springs, fixed in floor with over all length of cover plate 150mm completeall as specified and as directed. |
| 28 | Dismantling floor, hearth or wall tiling , terrazzo topping on wallsincluding cement mortar ,bedding (but no backing) removing serviceable tilesand rubbish off the premises complete all as specified and directed. |
| 29 | M&L for glass fibre reinforced modified cementitious coating system before the final coat of Latex of polymer-modified, slurry-based mortar designed for waterproofing concrete and masonry.Base coat: Styrene-Butadiene Latex-based liquid for waterproofing, bond coating, and crack repair to enhance the properties of cementitious mixtures, offering increased strength, durability, and resistance to water, chemicals, and acids. Consumption base coat: 0.3 kg/m2Reinforcement: Glass fiberSecond and Third coat: Latex of polymer-modified, slurry-based mortar designed for waterproofing concrete and masonryConsumption top coat: 3 kg/m2System requirements: density: 2.00 kg/ltr;compressive strength: 0.5 N/mm2.• Wall penetration through the RCC slab must be sealed using Polymer modified mortar designed for concrete and masonry repairs for enhancing adhesion, strength and durability.• Intersection of base slab with wall must be provided with a 50 mm fillet using Styrene-Butadiene Latex-based liquid modified mortar with a bonding coat of Styrene-Butadiene Latex-based liquid for waterproofing,modified cement slurry upto 5ft.• All depressions, unevenness, surface honeycombing shall be repaired using Styrene-Butadiene Latex-based liquid for waterproofing, modified polymer mortar with a bonding coat of Styrene-Butadiene Latex-based liquid for waterproofing, modified cement slurry.Including cleaning ofRCCsurface to remove dust, loose particles, etc with compressed air or any other suitable technique depending on site conditions, grinding any sharp edges, etc |
| 30 | M&L rendering 10 mm thick on fair faces of brick work or concrete surfaces in CM 1:4 with water proofing compound tobe finished even and smooth without using extra cementcompleteall as specified and as directed. |
| 31 | Supply onlyIntegral water proofing compound liquidcompleteall as specified and as directed. |
| 32 | S&F 20mm dia High density polyethylene pipes (HDPE) of pressure rating 6 kgf/cm2 laid in as spout pipes to pour out rsidual water out from the treated areacompleteall as specified and as directed. |
| 33 | M&L for hard core, of broken bricks broken to gauge n exc 63mm for laying sub base of thickness 150mm completeall as specified and as directed. |
| 34 | M&L Cementconcrete type D-2 1:4:8 (40mm graded crushed stone aggregate) in foundations, filling and mass concrete in sub basecompleteall as specified and as directed. |
| 35 | M&L for 25mm thick PCC (1:2:4) type B1 with 20mm graded aggregate for laying floor tilescompleteall as specified and as directed. |
| 36 | M&L for non skid coloured Ceramic tiles 8 to 10 mm thick in light shade (square/ rectangular) polished, area of each tiles exc 0.11 sqm but not exceeding 0.18 sqm, in floors/Skirting etc. set, jointed and pointed with Berger HS tile adhesive anti slip white @1.2kg/sqm thickness upto 8 to 10mm (or equivalent) and epoxy material for sealing of tile joints with Berger HS Epoxy tile grout(or equivalent) to the floor of toilets and bathroomcompleteall as specified and as directed. |
| 37 | Demolition of cement concrete in and paving (un reinforced)exc. 15 cm. thickness, below or above ground level, including removal of waste from defence land and dumping at a place as specified by civil authorities completeall as specified and as directed. |
| 38 | Demolition of cement concrete in and paving (un reinforced)n exc. 15 cm. thickness, below or above ground level, including removal of waste from defence land and dumping at a place as specified by civil authorities completeall as specified and as directed. |
| 39 | Non - skid ceramic coloured jointless tile400mm x 400mm x 7mm thick as in floors laid over and including 15 mm thick screed bed or bedding layer of cement mortar 1:4, set and jointed in neat cement slurry and pointed incoloured cement to match the colour of tiles completeall as specified and as directed. |
| 40 | Non - skid ceramic colouredjointlesstiles 400mm x 400mm x 7 mm thickon vertical surfaces such as skirting /dado etc bedded & jointed in neat cement slurry over and including 10 mm thickbacking coat of cement mortar 1:4and pointed in white or coloured cement to match the colour of tiles completeall as specified and as directed. |
| 41 | Glazed ceramic coloured tiles of size350x450x7mmthick as in vertical surfaces such as skirting, dado, wall etc., set and jointed in neat cement slurry and pointed with coloured cement to match over and including 10mm thick rendering in cement mortar 1:4,completeall as specified and as directed. |
| 42 | Vitrified coloured tiles, jointless , light shadeof size 600mm x 600mm x 9 to 10 mm thick, asin floors etc bedded & jointed in neat cement slurry over and including15 mm thick screed bedincement mortar 1:4 and pointed inwhite or coloured cement to match the colour of tiles, completeall as specified and as directed. |
| 43 | Vitrified coloured tiles,joint less ,light shade 600mm x 600mm x 9 to 10mm thick,on vertical surfacessuch as skirting / dado etc bedded & jointed in neat cement slurry over and including 10mm thick backing coat of cement mortar 1:4 and pointed in white or coloured cement to match the colour of tiles,completeall as specified and as directed. |
| 44 | M&L 18 to20mm thickblack Granite stone (table rubbed and polished) in cooking plateformbedded and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stoneover 15mm thick screed bed in CM 1:4 after roughingsurfaces of old concrete floor by picking sweeping down with water to remove dust etcincluding cutting holes into or through reinforced cement concrete slabs , for gas pipe(Superficial area wxc 100 sq cm but n. exc. 250 sq cmcompleteall as specified and as directed. |
| 45 | 20mm dia stainless steel drapery rods in one length per door/window as approved by GE providing with two nos of Bracket for holding curtain rod and Fiber fancy dome type or wall to wall fixed in repair completeall as specified and as directed. |
| 46 | S&F 300mm ordinary rat tail mild steel rod pattern springs incl roller and rollerplate completeall as specified and as directed. |
| 47 | Dismantling water tanks exceeding 250 ltr capacity but not exc 500 ltrs completeall as specified and as directed. |
| 48 | S&F Rotational moulded polythene water storage tank triple layervertical type with closed top hoisted and fixed in position all as spd in SSR part-I capacity 500 litercompleteall as specified and as directed. |
| 49 | S&F in repair 20 mm ballvalveshigh pressure of PTMT with epoxy coated , brass rod & high density plastic ballscrewed for iron pipe min wt 210 gmscompleteall as specified and as directed. |
| 50 | Taking up or down 15 mm steel tubing and connections including clearing for refixing or removal to storecompleteall as specified and as directed. |
| 51 | Taking up or down 20 mm steel tubing and connections including clearing for refixing or removal to storecompleteall as specified and as directed. |
| 52 | S&F Steel water tubing medium grade galvanised with all fittings including short lengths, fixed to walls, concealed in wall and ceiling or laid in floor complete with all fittings (such as bends, elbows, Tee, short pieces, connectors, back nuts, diminishing pieces, caps and plugs, unions etc.) of nominal bore dia15 mm, acompleteall as specified and as directed. |
| 53 | S&F Steel water tubing medium grade galvanised with all fittings including short lengths, fixed to walls, concealed in wall and ceiling or laid in floor complete with all fittings (such as bends, elbows, Tee, short pieces, connectors, back nuts, diminishing pieces, caps and plugs, unions etc.) of nominal bore dia 20 mm,completeall as specified and as directed. |
| 54 | Refixing old steel tubing and connections in new or old position with all fittings retrieved from Serial here-in-before and fixed (walls, ceiling, floors, etc) of 15 mm dia completeall as specified and as directed. |
| 55 | Refixing old steel tubing and connections in new or old position with all fittings retrieved from Serial here-in-before and fixed (walls, ceiling, floors, etc) of 20 mm dia completeall as specified and as directed. |
| 56 | S&F Vitreous china water closet Orissa pattern long pansize 580x440mmwith trap front or back inlet and integral foot rest complete fixed in repair including lime concrete bedding and connection to drain or outgoing pipe and to flushing pipe and anti siphon pipe complete all as specified and as directed. |
| 57 | S&F PVC flushing cistern whiteshade low level 10 ltrs capacity, white with inlet ball valve, float and handle including bracket and flush pipe including connection to pipes, fixed in repairs completeall as specified and as directed. |
| 58 | S&F PVC connection 15 mm size with PTMT nuts of length 600 mmcompleteall as specified and as directed. |
| 59 | Looking mirror 600 x 450 x 5mm beveled edge mirror of selected quality glass 5mm thick mounted on 6 mm thick AC building board or commercial ply and fixed to wooden plugs with CP brass screws and cup washers etc, fixed in repairs, completeall as specified and as directed. |
| 60 | Tubular towel rail, brass chromium plated, 20 mm dia, D type, 60 cm long between Hangs, fixed in repairscompleteall as specified and as directed. |
| 61 | S&F sinks with drainage board made of stainless steel 1mm thick kitchen or laboratory with plugs washers and wastes including bedding in cement mortar to dwarf wall or including fixing cantilever brickets and connecting union to pipe overall size 915mmx460mm bowl size 410mmx330mmx160mmcompleteall as specified and as directed. |
| 62 | S&F Stainless steel grating of 125mm size, male/female pattern with or without hole, fixed in nahani/floor traps with white/coloured cement, fixed in repairs, completeall as specified and as directed. |
| 63 | PVC 32mm dia waste pipe with CP coupling, completeall as specified and as directed. |
| 64 | S&F in repairs vitreous china wash hand basin corner type with white and glossy including all accessories completeall as specified and as directed. |
| 65 | S&F in repair Bib taps, chromium platedcast copper alloy, withcapstan head, screwed down for iron pipe or for brass ferrule and fixed for bore of pipe 15 mm, fixed in repairs,completeall as specified and as directed. |
| 66 | S & Fixed in repairs Angle stop valve cast copper alloy, with fancy type chromium plated capstan head, screwed down, high pressure screwed both ends for 15 mm bore iron pipe or for unions and fixed completeall as specified and as directed. . |
| 67 | S&F in repair CP brass hot & cold 15mm dia wall mixture with provision for overhead shower with 115 mm long bend pipe onupper sie connecting legs & wall flanges for mixing hot & cold water completeall as specified and as directed. |
| 68 | S&F in repair CP brass hot & cold 15mm dia 3 in1 wall mixturefor kitchen& wall flanges for mixing hot & cold watercompleteall as specified and as directed. |
| 69 | S & F in repairs Chromium plated shower rose 125 mm size with or without swivel joints, any size, including fixing tosteel pipe or unioncompleteall as specified and as directed. |
| 70 | S & F in repairs 20 mm dia Gun Metal, globe or Gate Valve with Iron wheel head Screwed both ends for Iron Pipe and fixed in repairscompleteall as specified and as directed. |
| 71 | Sheet glass shelf assembly consisting of 5,5mm thick sheet glass shelf 12cm wide with chromium plated bracket guard and railing 60cm long make Jaguar or equivalentcompleteall as specified and as directed. |
| 72 | S&F 600x450mm PVC cabinet mirror of superior quality completeall as specified and as directed. |
| 73 | Dismantling boarding any description fixed with screws completeall as specified and as directed. |
| 74 | 18/19mm thick Prelaminated particleboard, exterior grade, prelaminated one side with decorative choice lamination & other side balancing white lamination fixed with screws to timber frame workas incupboards , kitchen cabinat etc fixed in repairscompleteall as specified and as directed. |
| 75 | S&F Continuous (piano) hinges,width of flap when open is 30 mm mild steel, bright finish or electro galvanisedcompleteall as specified and as directed. |
| 76 | S&F 100 mm long Extruded Aluminium alloy handles, fabricated type, anodised.completeall as specified and as directed. |
| 77 | S&F Magnetic catches of 25/30 mm size for cup Board shutter etc completeall as specified and as directed. |
| 78 | S&F hasp and stapple, safety typeofAluminium, anodised, including bolt to hinge type, fixed with screws of 100 mm completeall as specified and as directed. |
| 79 | TMT steel bars 10mm dia and over, cut to length bent to shape required, including cranking, bending spirally for hooping to columns, hooking ends and binding with mild steel wire (annealed) not less than 0.90mm dia, completeall as specified and as directed. |
| 80 | TMT steel round bars 6 to 8mm dia and over, cut to length bent to shape required, including cranking, bending spirally for hooping to columns, hooking ends and binding with mild steel wire (annealed) not less than 0.90mm dia, completeall as specified and as directed. |
| 81 | Form work to soffit of suspended slab such as roof slab not exc 20 0 mm thick horizontal or slopinf flate including fair finished to concrete surfacescompleteall as specified and as directed. |
| 82 | M&L RCC 1:2:4 Type B-1 (using 20 mm graded aggregate) inRoof slab, shelves supported on wall/column and the like etc complete as requiredcompleteall as specified and as directed. |
| 83 | Providing Precast cement concrete 1:2:4 Type B-1 (using 20 mm graded aggregate) inlandings, cover slabs (for man holes etc) and the like etccompleteall as specified and as directed. |
| 84 | Demolition of reinforced cement concrete ( reinforcement cut as required to facilitate demolition)of any description and in any position not otherwise specifically provided forcompleteall as specified and as directed. |
| 85 | Demolition of cement concrete of any description and in any position not otherwise specifically provided for in plinth protectioncompleteall as specified and as directed. |
| 86 | 75 mm thick PCC1:3:6 type C-1, (using 20mm graded crushed stone aggregate) as in plinth protectionfinished even and smooth without using extra cement incl necessary jointscompleteall as specified and as directed. |
| 87 | Dismantling cast iron or reinforced concrete drain pipes of 75/100mm bore, fixed with walls and taking out of trenches, if required completeall as specified and as directed. |
| 88 | S&F PVC (SWR) pipes single socketed in any length with rubbering joints fixed to walls 110mm borecompleteall as specified and as directed. |
| 89 | S&F PVC (SWR) pipes single socketed in any length with rubbering joints fixed to walls 75 mm borecompleteall as specified and as directed. |
| 90 | S&F PVC (SWR) bends any radius 110mm bore with access doorcompleteall as specified and as directed. |
| 91 | PVC(SWR) junction single (single \"T\") equal or unequal 110mm bore with access to door ccomplete all as specified and directed. |
| 92 | S&F PVC (SWR) bends any radius 75 mm bore with access doorcompleteall as specified and as directed. |
| 93 | PVC(SWR) junction single (single \"T\") equal or unequal 75 mm bore with access to doorcompleteall as specified and as directed. |
| 94 | M & L for PVC (SWR)multi floor trap diameter of outlet 75 mm with grating including jointing with solvent cementcompleteall as specified and as directed. |
| 95 | S&F Plate rack made out of 1.00 mm thick stainless steel sheet of size 750mm x 750mm x250mm ,completeall as specified and as directed. |
| 96 | 75 mm thickPCC1:4:8 type D-2 using (40mm graded crushed stone aggregate) as in sub base of floor completeall as specified and as directed. |
| 97 | M&L for Machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 60 mm thickness, M-35 Gradecompleteall as specified and as directed. |
| 98 | Sand filling under floors or in foundations including watering and consolidationcompleteall as specified and as directed. |
| 99 | Preparation of new wooden surfaces of any description,over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer, completeall as specified and as directed. |
| 100 | M&L for two coats synthetic enamel paint over a coat of red oxide primer on newly steel surfaces completeall as specified and as directed. |
| 101 | Material and labour for preparation of newly plastered wall surface and applying two coat of premium acrylic smooth exterior emulsion of approved colour with silicon additive & Color stay Technology, Excellent Dirt Pick up resistance of Berger Paints Ltd or equivalent of other approved make with low VOC less than 50 gram/ litre as per the LEEDS specifications, Anti Algal properties in two coats @ 1.79 ltr (undiluted)/ 10 sqm diluted with water as per manufacturer instructions applied over one coat of acrylic water based exterior grade primer @ 0.9ltr(undiluted)/10 sq mtrs diluted with water in 1:1ratio as per manufacture\"s instruction and all coats incl primer to be applied with fully automatic airlessspray machine of paint application with a flow speed of minimum 1 ltr per minute having a pressure of 3300 PSI. Allow 6-8 hrs to dry the surface in subsequent coats of paint complete all as specified and directed.Note :-(a) Work shall be done as per MoU between tenderer and manufacturer of paints and their authorized applicator complete all as specified and directed (b) The contractor shall upload MoU between tenderer and manufacturer of paints and their authorized applicator after conclude of tender and before place of Work Order Documents as mentioned in NIT.(c) The work pertaning to periodical services & water proofing shall be executed from authorized applicator through manufacturer of which the material i.e.paint, distemper, cement base paint, putty etc. is proposed to be used by the contractor and approved by GE |
| 102 | Material and labour for complete removal of existing treatment including fascias, cornices etc by scrapping with mechanical wall sander (having mechanical vacuum mechanism) having RPM not less than 1500, sanding pad of 80 Grit having dia of 7\"/9\" to make the surface free from dust, loose paint and loose plaster to be completely removed by skilled labour and repair of external wall/Chajjas to be done with repair mortar to get even surface including preparation of old surface of wall/ceiling by filling cracks by Berger Bison Putty / crack fill paste of Berger Paints or equivalent make and make good smoothen surface by sand paper and applying two coats of premium acrylic smooth exterior emulsion of approved colour with silicon additive & Color stay Technology ,Excellent Dirt Pick up resistance of Berger Paints Ltd or equivalent of other approved make with low VOC less than 50 gram/ litre as per the LEEDS specifications, Anti Algal properties in two coats @ 1.79 ltr (undiluted)/ 10 sqm diluted with water as per manufacturer instructions applied over one coat of acrylic water based exterior grade primer @ 0.9ltr(undiluted)/10 sq mtrs diluted with water in 1:1ratio as per manufacture\"s instruction and all coats incl primer to be applied with fully automatic airless spray machine of paint application with a flow speed of minimum 1 ltr per minute having a pressure of 3300 PSI all as specified and directed.Allow 6-8 hrs to dry the surface in subsequent coats of paint and including necessary scaffolding at any height complete all as specified and directed Make: Berger Paints Weathercoat Long Life Flexo/ Nerolac Paints excel Total / Asian Paint Apex Ultima |
| 103 | Complete removal of existing treatmentfrom internal wall/ceiling surfacesincluding preparation of oldsurfaces and applying one coat of oil bound distemper over 3mmthick wall care putty completeall as specified and as directed. |
| 104 | Preparation of new plastered surfaces and applying two coats of oil bound distemper on walls/Ceilingover3 mm thick wall care puttycomplete all as specified and directed. |
| 105 | Demolition of brick work or stone masonary built in cement mortarincluding all quoins , arches,pillar etc but excluding ashlars facing dressed stone work and pre-cast concrete article completeall as specified and as directed. |
| 106 | M&L Brick work with sub class ‘B’ bricks, straight or curved on plan exceeding 6 m mean radius built in cement mortar 1:6, complete, all as specified and as directed. |
| 107 | Brick work with sub class ‘B’ bricks ,straight or curved on plan exc 6 m mean radius and built in cement mortar1:6 complete , but except bricks , i.e using serviceable bricks obtained from demolitioncompleteall as specified and as directed. |
| 108 | Capillary rise treatment of walls, Consumption base coat: 0.3 Kg/Sqm, Second and Third coat : Latex sheild 2K (or equivalent), Consumption top coat: 3 Kg/Sqm, System requirements : density : 2.00 Kg/Ltr, Compressive strength: 0.5 N/Sqmm. complete all as specified and as directed. |
| 109 | Providing cement concrete type B-0 1:2:4 (using 12.5 mm graded stone aggregate ) in roof padding, roof kerbs or mud stops, rounded or chamfered on edgescompleteall as specified and as directed. |
| 110 | Complete removal of existing roof treatment or roof tile and removing from site to a place outside defence land as specified by civil authorities and clean the surface of roof with water and remove dust completeall as specified and as directed. |
| 111 | M&L for highly elastic, UV-resistant membraneone-component, water-based, liquid, and solvent-free coating for adhesion on various surfaces, including porous and non-porous substrates,with ability to bridge cracks ,cold applied , water-proofing membrane that is highly elastic and UV resistant with 10 years Warranty .ASTM D 6083-97a Waterproofing and heat reflecting system having following key performance properties:1.UV resistant ,prevent yellowing and weathering2.Highly elastic upto 350% and crack bridging3.Excellent adhesion on porous and non-porous substrates4. Tensile Strength >10 N/mm2 with GeoTextile fleece5. Soler Reflective Index (SRI) more then 109-111ASTM E1980-11System: First coat:Providing and applying OEM prescribed compatible primer over the prepared surface for adhesion and bridging cracks.Coverage: 0.2kg/m2(with 50% dilution of waterReinforcement: Geotextile 40 gsmSecond coat: highly elastic, UV-resistant membraneone-component, water-based, liquid, and solvent-free coating for adhesion on various surfaces, including porous and non-porous substrates,with ability to bridge cracks.Consumption: 0.5 kg/m2.Third coat: highly elastic, UV-resistant membraneone-component, water-based, liquid, and solvent-free coating for adhesion on various surfaces, including porous and non-porous substrates,with ability to bridge cracks.Consumption : 0.8 kg/m2.System buildup-1.5kg/sqm with geotextile of 40gsmFor accessible roof, tiles with screed/ adhesive may be fixed thereafter. |
| 112 | Takingout carefully copper/aluminium point wiring,Light,fan,socket or powercomplete with all fitting, fixtures such as switch socket out let, ceiling rose ,holder ,regulator,DBs etc including making good the disturbed surface of wall/floors completeall as specified and as directed. |
| 113 | Taking down distribution boards/wooden board ,switch fuse units,steel enclosures for MCB of any type and removing from site completeall as specified and as directed. |
| 114 | Taking down existing unserviceable submain wiring any size and making good the disturbed surface completeall as specified and as directed. |
| 115 | Taking down Electric meter any type including disconnection electrically and refixing the same at same or new location completeall as specified and as directed. |
| 116 | M&L for point wiring for one light/fan/bell point controlled by a one-way switch, using 1.5 sqmm FRLS PVC insulated, sheathed, single-core multi-stranded copper conductor cable (1100V grade), drawn through rigid non-metallic PVC concealed conduit (medium grade) of suitable diameter, including 1.5 sqmm FRLS copper earth wire connected to the earth dolly. Wiring shall be terminated in pressed steel sunken boxes with a minimum wall thickness of 1.22 mm (up to 200x300 mm) or 1.63 mm (for larger sizes), complete with cover & frame for mounting accessories with and including cutting chase for fixing conduite and making good to the disturbed surfaces of wall appx 3 RM for each points ,all as specified and directed.NOTE- (For Item no 116 to 120) Modular switch/ socket 5/15/20 Amp will be measured seprately under respective item. |
| 117 | All as per ser item No 116 hereinbefore but for one 3 pin socket outlet 5 Amp Same boardcompleteall as specified and as directed. |
| 118 | All as per ser item No 116 hereinbefore but for one 3 pin socket outlet 5 Amp independentcompleteall as specified and as directed. |
| 119 | All as per Item no 116 here-in-before but for one15 Amp 3pin switch socket outlet, independent with 2 Sqmm single core multi-stranded copper conductor cable (FRLS) along with 2.5 sqmm continuous PVC insulated unsheathed single core multi-stranded copper conductor (FRLS) cable for earth continuity wire all as specified and as directed. |
| 120 | All as per item No 116 above but One light point controlled by two way switchcompleteall as specified and as directed. |
| 121 | Supply and fix modular type switch, one way 6 Amps , 1 module complete all as specified and directed. |
| 122 | Supply and fix modular type switch, Two way 6 Amps , 1 module complete all as specified and directed. |
| 123 | Supply and fix modular type switch, one way 16 Amps, 1 module complete all as specified and directed. |
| 124 | Supply and fixmodular type socket 5 pin, 6 Amps 2 module complete all as specified and directed. |
| 125 | Supply and fixmodular type socket 5 pin, 6 A/16 Amps2 module completeall as specified and as directed. |
| 126 | Supply and fix of Ceiling rose surface bakelite three terminals 240 voltscompleteall as specified and as directed. |
| 127 | Supply and fix Lamp holder PVC case body of Bakelite with back plate suitable for batten fittings , completeall as specified and as directed. . |
| 128 | Supply and fix LED lamp,6500K,900lm in white colour of 12 Watt base cap B-22 with poly carbonate difusser and aluminium heat sink ,completeall as specified and as directed. |
| 129 | Electronic fan regulator stepped type,two modulewith five step 240 volts,100Watt suitable for 1200/1400 mm sweep AC ceiling fan completeall as specified and as directed. |
| 130 | Supply and fix of Bell push flush type piano 5 Amp completeall as specified and as directed. |
| 131 | Supply and fix Bell multi music 230 volt ,AC single pole completeall as specified and as directed. |
| 132 | S & F LED light fitting 1x9W/1X10Wbulkhead luminaires including LED light driver holder connecting up with three core flexible copper conductor cable of suitable sizecompleteall as specified and as directed. |
| 133 | Supply and fixing LED lights fitting 1x 20W, 220V,AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose completeall as specified and as directed. |
| 134 | Supply and fixing LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size completeall as specified and as directed. |
| 135 | Supply & Fix20 A SPN MCB‑Protected Socket Combo surface‑mounted PVC‑plastic base with steel enclosure, rated 20 A, 230 V AC, including 20 A/10 kA SP B‑curve MCB , IS:13032 & IS:8623 compliant, suitable for geyser points, completeall as specified and as directed. |
| 136 | S&F of sheet metal enclosure DB TPN 4 way, double door, 415 volts AC, surface mounting complete with suitable busbar, neutral link & earth link suitable for MCB TP/TPN as incomer & MCB SP as outgoing completeall as specified and as directed. |
| 137 | S&F of sheet metal enclosure DB SPN 8 way, double door, 230 volts AC, surface mounting complete with suitable busbar, neutral link & earth link suitable for MCB DP/SPN as incomer & MCB SP as outgoing completeall as specified and as directed. |
| 138 | S&F of MCCBs, TPN, 100 Amps, 415 volts, 10 kA rupturing capacity, B curve type completeall as specified and as directed. |
| 139 | S&F of MCBs, SP, 40-63 Amps, 230 volts,10 kA rupturing capacity, B curve type completeall as specified and as directed. |
| 140 | S&F of MCBs, SPN, 32 Amps, 230 volts, 10 kA rupturing capacity, B curve typecompleteall as specified and as directed. |
| 141 | S&F of MCBs, SP, 6-32 Amps, 230 volts,10 kA rupturing capacity, B curve type completeall as specified and as directed. |
| 142 | Material and labour for sub-main wiring with two runs of single core 6 sqmm PVC insulated (unsheathed) multi-strand copper conductor FRLS cable for phase and neutral, and one run of single core 4 sqmm PVC insulated (unsheathed) multi-strand copper conductor FRLS cable for continuous earth, drawn through and including medium grade 25mm dia ISI marked concealed PVC conduit, complete with conduit fittings and accessories. Work includes cutting chases, pinning in, making good to facing and pointing with cement mortar (1:3), restoring disturbed surfaces, and taking down old unserviceable sub-main wiring, completeall as specified and as directed. |
| 143 | Supply, installation, testing, and commissioning of sub-main wiring using two single-core 2.5 sqmm FRLS PVC insulated (unsheathed), multi-strand copper conductor cables, along with one single-core 1.5 sqmm FRLS PVC insulated (unsheathed), solid copper conductor cable as continuous earth wire, drawn through and including ISI-marked 25mm dia concealed PVC conduit (medium grade), complete with all necessary fittings and accessories. The work includes cutting chases, fixing conduits, pinning, restoring surfaces with 1:3 cement mortar, and making good any disturbed areas. It also includes taking down and removing old unserviceable sub-main wiring, completeall as specified and as directed. |
| 144 | S&F single core PVC insulated unsheathed multistanded copper conductor cable 1 Sqmm , 1100 Volts ISI marked drawn through existing point wiringcompleteall as specified and as directed. |
| 145 | Material and labour for earthing complete with galvanized steel plate electrodes of size 600mm x600mm x 6mm thick buried dirctly in ground with earth pit not lesss than 2.25m deep below normal ground level with top edge of plate not less than 1.5 m below normal ground level connected to galvanized iron strip of 32 x 6 mm earthing lead by means of nuts bolts check nuts GI washers earth wire protected by GI pipe 32 mm bore, light grade, including concrete pit in PCC (1:3:6) type C1 of size 45x45x45 cm, precast RCC (1:2:4) type B1 as cover of size 40x40x10 cm with one handle for lifting made out of 8 mm dia MS bar, GI funnel wire mesh, 20 mm bore GI pipe, medium grade, for watering, charcoal or coke and salt packed all around in alternate layers necessary earth work in soft/loose soil complete all as shown in electrical plate No 3 of SSR Part-I including testing on completion including demolition to existing one complete all as specifed and directed. (Note :- (i) PCC pit, RCC pit cover, GI earth protection & watering pipe, funnel, earth strip upto 7.5 Mtr etc shall deemed to be included in the unit rate. (ii) GI earth strip above 7.5 m length, if required,for earthing shall be paid measured and seperately as \"Supply only\". |
| 146 | Supply and fixing LED street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete. including GI pipe 40mm ,medium grade ,1.7mtr long mounting bracket and providing fixing clamps ,bolts,nuts of suitable sizecompleteall as specified and as directed. |
| 147 | Taking down carefully the ceiling fan or exhaust fan from its existing position including disconnection of electric connections, completeall as specified and as directed. Note: taking down old unserviceable ceiling fan or Exhaust fan of any type/size from existing location and depositing in MES store, complete all as specified & directed by Engr-in-charge. |
| 148 | S & F for Exhaust Fan plastic body, 250 mm(12\") sweep, single phase, 230 volts 50 Hz AC,1200 RPM, energy saving, heavy duty totally enclosed, heavy duty motor with die-cast aluminiun rotor mounted on two ball bearings complete with louvers and shutters including cutting hole for fixing exhaust fan to wall and making good the disturbed surfaces (including plastering, necessary brickwork and distempering) to match with the existing specification, connecting electrically using 3 core 0.75 Sq mm PVC insulated flexible copper conductor cable over all sheathed all as required at site completeall as specified and as directed. |
| 149 | S & F for Exhaust Fan plastic body, 300mm(12\") sweep, single phase, 230 volts 50 Hz AC,1400 RPM, energy saving, heavy duty totally enclosed, heavy duty motor with die-cast aluminiun rotor mounted on two ball bearings complete with louvers and shutters including cutting hole for fixing exhaust fan to wall and making good the disturbed surfaces (including plastering, necessary brickwork and distempering) to match with the existing specification, connecting electrically using 3 core 0.75 Sq mm PVC insulated flexible copper conductor cable over all sheathed all as required at site completeall as specified and as directed. |
| 150 | Supply install testing and commissioning of 1200mm sweep 230 volts AC ceiling fan , five star BEE rating confirming to IS 374:2019, 3 bladealong with copper wound stator , with minimum air delivery 210 cubic metre per minute ,aluminium blades , capacitor ,downrod, canopy etc as required including making connection with three core 1.5sqmm flexible copper cable upto ceiling rose completeall as specified and as directed. |
| 151 | Supply,install and testing water heater storage type(Geyser)single phase 230V,50Hz ,5 star energy saving high density PUF insulation tank made of heavy duty magnesium anode rod with steel core to protect enamelled tank from rust & corrosion ,vertical installation type, 25 Litre capacity,2000Watt rated power,incoloy 800 glass coated heating element,tank coating of feroglas powder,tank made of ultra thick super cold rolled steel plates,rated pressure 0.8MPa,IPX4 protectionconsist of safety valves,thermal cut off, thermostat including connecting up fixed to walls by drilling of holes ,grouting of bolts of suitable size with nuts etc and makinggood disturbed surface completeall as specified and as directed. |
| 152 | Taking down and repixing of tamper proof with inbuilt intelligence electronic Energy meter single phase, two wire direct connected meter with parameter (voltage P-n, PF, Frequency current line KW demand, LDC display, optical port class 1.0s), 240 volts 10-60 Amps complete with meter box single phase with locking arrangements molded in UV stabilised transherant/flame retardant high grade engineering plastic with unique arrangements for plifer proof interlocking with hinge type box with connection of suitable size wire including seal and sealing wire and furnishing details of Qtr No, Meter No, Initial reading writing with paint of MES No completeall as specified and as directed. |
| 153 | Cutting existing steel tubing15 mm bore for alterations or additions (Each cut measured)completeall as specified and as directed. |
| 154 | S & F Tubes medium grade galvanized 15 mm dia with fittings such as socket, bend and fixed complete to walls and ceilings completeall as specified and as directed. |
| 155 | S&F Stop valve/angle valve cast copper alloy screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe of four unions and fixedcompleteall as specified and as directed. |
| 156 | S&F Bib tap 15mmchromium platedcast copper alloy with crutch or butterfly screwed down for iron pipe and fixedcompleteall as specified and as directed. |
| 157 | Dismantling and taking out rusted/corroded pipe GI/CPVC of size 20/25/40mm bore completeall as specified and as directed. |
| 158 | M & L of tubing GI \"MG\" with all fittings laid in floor or trenches including taking out old UNSV pipe of size 40 mm diacompleteall as specified and as directed. |
| 159 | M & L of tubing GI \"MG\" with all fittings laid in floor or trenches including taking out old UNSV pipe of size 25 mm dia completeall as specified and as directed. |
| 160 | M & L of tubing GI \"MG\" with all fittings laid in floor or trenches including taking out old UNSV pipe of size 15 mm dia completeall as specified and as directed. |
| 161 | M & L of gun metal globe or gate valve with iron wheel head, screwed both ends for iron pipe and fixed of size 40 mm borecompleteall as specified and as directed. |
| 162 | M & L of gun metal globe or gate valve with iron wheel head, screwed both ends for iron pipe and fixed of size 25 mm borecompleteall as specified and as directed. |
| 163 | Cutting existing 80/100/150 mm GI pipe and inserting GI Tee of size 100x100x50 mm for tapping including necessary earth work and making flange for connection of new 50 mm of GI pipe including completeall as specified and as directed. |
| 164 | Excavation in trenches, n. exc1.5 m wide and n. exc 1.5 m in depth for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, cables etc. not exc. 10 sq m on plan and n. exc1.5 m in depth and getting out in soft / loose soil complete all as specified and as directed.Note : All excavation for taking out and re-laying of cables shall be carried out mannualy and paid under this relevent item. |
| 165 | Removing excavated material not exceeding 50M and depositing where directed at a level not exceeding 1.5 metre above the starting pointcompleteall as specified and as directed. |
| 166 | Returning, filling in, including spreading, leveling, watering and well ramming in layers not exceeding 25 cm thick with soils completeall as specified and as directed. |
| 167 | Taking out/down unserviceable, defectivecable any Type/size including disconnecting all the electrical connections all as required at site completeall as specified and as directed. |
| 168 | Material and labour for cable XLPE insulated screened PVC bedded, galvanised steel strip or wire armored, electric power cables (heavy duty 1100 Volts grade with stranded aluminium conductor of size 16 Sqmm 4 Core, including glands, lugs, nut, bolts, washers as required at site, testing completeall as specified and as directed. |
| 169 | Sand cushioning to underground cables provided with a layer of sand 8cm thick before laying the cable in trenches and 15cm thick after laying the cable in trenches completeall as specified and as directed. |
| 170 | S & F Steel pipe glavanized grade of 50 mm bore laid in trenches or under ground/floor or road of fixed with pole for protection of cable including clams with bolts nuts and wasers completeall as specified and as directed. |
| 171 | Sub class ‘B’bricks for covering to cable laid dry flat ,with width equal to the length of brickcompleteall as specified and as directed. |
| 172 | M&L for cutting hard standing to a width of 0.2 M and depth not exceeding 1 mtr for laying of GI pipe line for strip protection and making good to match with the existing surface completeall as specified and as directed. |
| 173 | M&L for PCC 1:2:4 type B1 with 20 mm stone aggrgate as for make good for resufacing completeall as specified and as directed. |
| 174 | Demolition and breaking up drain pipes (Salt glazed ware, AC or Reinforced concrete) set in cement mortar, internal dia of pipe 150 mm, completeall as specified and as directed. |
| 175 | Concrete bed to drain pipes including packing under, and haunching againstthe sides of pipes after they are laid and tested; in cement concrete 1:3:6 type C-2 (using 40mm graded crushed stone aggregatefor 150mm dia bore pipes allas per SSR Part-I specifications, completeall as specified and as directed. |
| 176 | S&F 150mm diameter DWCPE (SN8) HDPE Pipes laid in trenches on PCC bed including jointing as per manufacturer\"s instructions completeall as specified and as directed. |
| 177 | Cutting into existing manholes for connecting new drains (internal dia of pipe 150mm), making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-1 smooth finished, and reforming benching as requiredcompleteall as specified and as directed. |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail