| 1 | Demolition/Dismantling of Brickwork or stone/ boulder masonry, built in cement mortar incl all quoins, arches, pillars, etc, complete all as specified and directed. |
| 2 | M&L for Brickwork with subclass \"B\" bricks (old size bricks), straight or curved on plan exc 6m mean radius, built in CM 1:6 complete all as specified and directed. |
| 3 | All as per item No 02above but except bricks. |
| 4 | M&L for brick work with sub class ‘B’ bricks (old size brick) straight or curved on plan to any radius in half bricks thick walls, built in CM 1:4 complete all as specified and directed. |
| 5 | M&L for preparation of new plastered surface and applying two coats of oil emulsion distemperon wall over one coat of primer etc complete all as specified and directed. |
| 6 | M&L for preparation of new plaster surface & apply twocoats of cement based paint over a coat alkali primer resistance and complete all as specified and directed. |
| 7 | M&L fortwo coat ofAcrylic smooth exterior emulsion paint over one coat of acrlic primer incl preparation of new plasterd surface complete all as specified and directed.Note : Colour and make as approved by GE. |
| 8 | M & L for preparation of new plastered surface and applying two coats of oil emulsion distemperon ceiling over one coat of primer etc complete all as specified and directed. |
| 9 | M&L forpreparation of old surfaces by removal of existing treatmen and applying two coats of oil emulsion distemper over a coat of primer on surface of walls through electrical operated grinder etc, complete all as specified and directed. |
| 10 | M&L forpreparation of old surfaces by removal of existing treatmen and applying one coat of oil emulsion distemper over a coat of primer on surface of walls through electrical operated grinder etc, complete all as specified and directed. |
| 11 | M&L for reparing of RCC projection, chajja, roof facia, cellingby scrapping, cutting, derusting and cleaning exposed reinforcement surfaces of damaged loose RCC surface and applying neat cement slurry @ 3 kg/Sqm and filling the surface with cement plaster1:3 one or two layer as reqd or PCC 1:2:4 as directed by Engr-in-Charge with or without facia and smooth finished and smotth edgesincl two coats of finished to match with the existing surface at any height and in any situation including necessary form workcomplete all as specified and directed. |
| 12 | M&L cement concrete type B-2 1:2:4 (40mm graded stone aggregate) as in walls or retaining walls, any thickness, size or shape includingpilasters buttreses columns, pillars, boundry pillars and posts and like for fixing of angle iron on top of boundry wall , including form work complete all as specified and directed. |
| 13 | M & L for TMT bars 10mm dia and over, cut to length, bent to shape required, incl cranking, bending spirally for hooping for columns, hooking ends and binding with themild steel wire (annealed) not less than 0.9mm dia or securing with clips and complete all as specified and directed. |
| 14 | All as per item No 13 above but 6 to 8 mm dia and over and including in stirrups, spacers and binders. |
| 15 | Taking down cement plaster of any description on concrete surfaces such as soft it of RCC slab, chajjas and brick walls etc inck raking out joints hacking for key scrubbing down with water etc complete all as specified and directed. |
| 16 | M&L for rendering 15mm thick in CM 1:4 on of brick work or concrete surface finish ever and smooth (w/o using extra cenent) incl WPC as per user manual at any height etc complete all as specified and directed.Note : WPCwil be measured and paid separately |
| 17 | M&L preparation of newly plastered surfaces, and applying two caoatof weather paint (Apex) paint over a coat of exterior primer colour and tint as ordered OR in CCD pattern upto 15 meters height on wall sides and soffits of the beams, ceiling, facias parapets etc complete all as specified and directed. |
| 18 | M&L preparation of old painted steel and iron surfaces of any description by brooming down or steel wire brushing, scapping down smoke soot moulds, moss and efflorescent salts and greasy spots of roof/ CGI Sheets, steel gates steel doors, steel rolling shutters, steel eves boards etc, exc 10cm width or girth applying one coat of synthetic enamel paint in colour and tint as ordered OR in CCD pattern upto 15 metres height complete all as specified and directed. |
| 19 | Complete removal of existing surface treatment from the old plasterd pointed/ concrete surfaces vertical or horizontal including brooming down for steel worir brushing, scrapping down, smoke soot moulds moss and efflorescent salts and greasy sports etc complete all as specified and directed. |
| 20 | M&L for two coat of exterior emulsion paint (weather coat) over a coat of exterior primer, colour and tint as ordered OR in CCD pattern upto 15 metres height including sides and soffits of the beams, ceilings, fascias, parapets etc complete all as specified and directed. |
| 21 | M&L for preparation of old plastered/ unplastered old decorated surfaces of wall pillars, cornicers by brooming down or steel brushing, scraping down smoke roots moulds moss and efflorescence salts trading oil greasy spots etc and applying one coat of exterior emulsion paint (weather coat ) over a coat of exterior primer colour and tint as ordered OR inCCD pattern upto 15 m height including sides and soffits of the beam ceilings fascats parapets etc complete all as specified and directed. |
| 22 | Dismantling of plain or corrugated steel sheeting, any gauge thickness including Nainital or similar pattern roof coverings complete all as specified and directed. |
| 23 | S&F 0.63 mm thick Galvanised, corrugated mild steel sheeting with two corrugations side lap with L type or J-type or cranked hook bolts in lieu of screws in roofs, wall etc with grade of zinc coating complete all as specified and directed. |
| 24 | All as per item No 23 but except Sheets. |
| 25 | S&F 0.63 mm thick Plain, galvanised,mild steel sheeting in ridges, hips valley gutters drip and straight flashings (length and girth as fixed) with grade of zinc coating complete all as specified and directed. |
| 26 | M&L for preparing new zinc (or galvanised) surfaces to receive painting by coating with mordant solution including washing and cleaning etc steel and iron surfaces and applying two coat of synthetic enamel paint of any description over 10 cm width or girth in CCD pattern as approved complete all as specified and directed. |
| 27 | S&F for 110 mm bore PVC pipes single socketed pressure rating @ 4Kg/Sq cm length \"Medium grade\" with rubber ring joint, fixed to walls with dash ture nut and bolt at every 2 mtrs length complete, incl taking up/down old pipe with all fittings complete all as specified and directed. |
| 28 | M&L for one layer of 3mm thick external wall care Putty /compound for external wall Surfaces ofBldgon oldscraped surfaces or new plastered surfaces and obtain smooth finish using sand paper incl complete removal of existing treatment complete all as specified and directed. |
| 29 | M&L for anodised aluminium framed workfor door, window / vent (powder coated)aluminium section weighting 0.55kg/RM with one or more rebated incl jointed cleat for fixing etc complete all as specified and directed. |
| 30 | M&L for anodised aluminium powder coated door shutter , aluminium section weighting not less than 0.55kg/RMincl necessary 4.8mm th sheet glass ordinary quality / frosted glass or ACP sheet incljoining with cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, handles, lock , 2 x 150mm aluminium handles, 3 x 100mm hinges aluminium, 2 x 150mm Aluminium tower bolts,1xdoor stoper,1xHydralic door closer with each shutter any type incl taking down complete all as specified and directed. |
| 31 | M&L for anodised aluminium powder coated window and ventilator shutters, aluminium section weighting not less than 0.55kg/RMincl necessary 4.8mm th sheet glass ordinary quality glass/ frosted incl joining with cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, handles, lock , 2 x 150mm aluminium handles, 3 x 100mm hinges aluminium, 2 x 150mm Aluminium tower bolts complete all as specified and directed. |
| 32 | M&L for aluminium Anodizedpowder coatedfixed frame of partiton or fixed window / ventilator , aluminium section weighting not less than 0.55kg/RM incl 4.8mm thick sheet glass oridinary quality \" frosted glass or ACP sheet joining with rubber beading , aluminium snap beading complete all as specified and directed. |
| 33 | S&F aluminium wire guard mesh of 4mm nominal dia of wire and average width of aperture 75 - 85mm and fixed with aluminium frame / staples complete all as specified and directed. |
| 34 | M&L for 4.8 mm thick float glass ordinary quality\" frosted glass and glazing with aluminum beeding and gasket to aluminum frameworkin squareexc 0.50 sqm ineach pane in repair complete all as specified and directed. |
| 35 | S & F for plain gypsum board panel 12.5mm thick on ceiling with and incl necessary GI frame used with \" T \" or any section accessories etc of galvanized steel all as per manufacturer design conforming to IS-2095 and 2542(1981) the weight of the board shall be not less than 7 kg per sqm incl dismantling of walls and ceiling board any type and two coat of OBD over a coat of putty complete all as specified and directed. |
| 36 | M&L in repair for PVC hollow wall panelling 7 to 8mm thick any colour/design approved by engr-in-charge,inclusive of fixing on to wall incl moulding end caps fixed with PVC sleeves and screws as requiredat site complete all as specified and directed |
| 37 | S & Ffor 10 -12 mm thick glass door, frosted with certain logo, fixed with floor spring, fixed on floor with two nos stainless steel handle of 300mm on each leaf and fixed partition arrangement incl necessary provision to lock the door complete all as specified and directed. |
| 38 | M&L for providing and fixing 10 mm thick plaster of paris ceiling (Gypsum anhydrous) of approved design/ pattern toflat surfaces incl all necessary MS frame work, 12 mm thick board and fittings as per standard practice and as per manufacturer\"s instrs reinforced with GI wire meshincl dismantling of walls and ceiling board any type complete all as specified and directed. |
| 39 | M&L for providing & fixing False ceiling with Gypsum based ceiling tiles and frame work (with aluminum foil on one side) of size 595 x 595 mm of thickness not less than 9 mm includingwith GIpowder coated frameangle /tee grid frame work for ceiling with following specfication(a)S&F Angle of side 25x25x1mm powder coated (b) 25x25x1 mm GI powder coated at Bottom tee as in main member(c) 25x25x1 mm thick GI powder coated at bottom tee as ibn cross members (d)S&F 1.6mm dia GI wire suspenders alongwith adjustable clamps to maintains levelinginculding fixing to ceiling fasteners & dismantling of walls and ceiling board any type complete all as specified and directed. |
| 40 | M&L for coral wall texture paint flasks type consisting of fiber natural gem, semi-precious pigmented granules, pearl and spary texture of high resistance, fire proof polymer alkali resistance, anti-corrosion and anti-condensation with natural stone, lime stone quartz etc that given a scam less wall surface without joints, reples water ultra violet rays from sunlight including removing of, alage and fungus applied on wall or ceiling with trowel and roller complete all as specified and directed. |
| 41 | M&L for Finishing walls with textured exterior paint of required shade : New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including priming coat of exterior primer applied @ 2.20kg/10 sqm including removing of, alage and fungus applied on wall with trowel /roller complete all as specified and directed. |
| 42 | Taking down existing roof treatmentof any description and any type complete all as specified and directed. |
| 43 | M & L for Roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust, inclBrushing neat cement slurry with 3.0kg of cement per sq. metreetc complete all as specified and directed. |
| 44 | M&L, Rendering 15mm thick in CM 1:4 onof brick work or concrete surfacefinish ever and smooth (w/o using extra cement) incl WPC as per user manual at any height etc complete all as specified and directed. |
| 45 | M&L for preparation of roof surface & applying evenly a tack coat of industrial bitumen 85/25 grade @ 1.2 Kg/SqmincludingAPP based polymeric membrane minimum weighing 3 kg/sqm and minimum 3 mm thick reinforced wih polyster non wove fabric (wt not less than 150 gms/sqm) land on primed surface by forced application, joints to be touched hot and width of overlaps not be less than 150 mm complete all as specified and directed. |
| 46 | M&L for Chicken wire mesh of size 12.5 mm and wire dia 0.51 mm (24 SWG) hexagonal construction, stretched firmly for roof treatment, complete all as specified and directed. |
| 47 | M&L for PCC (1:2:4) nominal mix, type B-0, using 12.5mm graded stone aggregate in roof paddingand surface finished even and smooth without using extra cement, complete all as specified and directed. |
| 48 | M&L for Making benching with PCC (1:2:4) type B0 using WPC along side wall adjoining to roof in concave shape complete all as specified and directed. |
| 49 | Removing plants / sherbs duct wall , junction with roots using herbicide chemical of existing brick or concrete for multistoried building at any storeyed and any height and match the surface with existing surface using 1:3 CM, complete all as specified and directed. |
| 50 | S&F for rotational moulded polyetheylene water storage tanks tripple layer (cylingrical verticlal with closed top) of 500 ltr capacity, hoisted and fixed in any position incl 20 mm dia ball float valve with aluminium fitting, GI nipple and any fitting ,dismantling existing water tank complete all as specified and directed. |
| 51 | S&F for rotational moulded polyetheylene water storage tanks tripple layer (cylingrical verticlal with closed top) of 1000 ltr capacity, hoisted and fixed in any position incl 20 mm dia ball float valve with aluminium fitting,GI nipple and any fitting , tank cover dismantling existing water tank complete all as specified and directed. |
| 52 | S&F for Disconnecting existing tanks, setting aside (or lowering if required) for repairs, cleaning, etc. for Cleaning and removing all scale and dirt, etc, from tanks and from mouths of circulating pipes, etc and hoisting if required reconnecting and re-fixing in position. (incl writing in white paint of 150mm size \" Tank cleaning on dt _______ \" complete all as spd and dir by EIC.(a) Tank Capacit exc 250 Ltr but n exc 500 Ltr. |
| 53 | S&F for Disconnecting existing tanks, setting aside (or lowering if required) for repairs, cleaning, etc. for Cleaning and removing all scale and dirt, etc, from tanks and from mouths of circulating pipes, etc and hoisting if required reconnecting and re-fixing in position. (incl writing in white paint of 150mm size \" Tank cleaning on dt _______ \" complete all as spd and dir by EIC.(a) Tank Capacit exc 500 Ltr but n exc 1000 Ltr. |
| 54 | Taking up or down 15 mm dia bore steel tubing and connection including cleaning for refixing or removed to store complete all as specified and directed. |
| 55 | S&F for GI tubing 15mm boremedium grde with all fittings and fixed complete to wall and ceiling or laid in floors etc incl cutting chases in brick wall pinning in making good in CM 1:3 to facings where required complete all as specified and directed. |
| 56 | S&F GI tubing 15 mm bore medium grade medium grde with all fittings and fixed complete to wall and ceiling or laid in floors complete all as specified and directed. |
| 57 | Fixing only in repair steel tubing and connection 15 mm dia bore to wall and laid in floors complete all as specified and directed. |
| 58 | Taking up or down steel tubing and connection including cleaning for refixing or removed to store, 20 mm dia bore complete complete all as specified and directed. |
| 59 | S&F GI tubing 20 mm bore medium grade medium grde with all fittings and fixed complete to wall and ceiling or laid in floors complete all as specified and directed. |
| 60 | Fixing only in repair steel tubing and connection 20 mm dia bore to wall and laid in floors, complete all as specified and directed. |
| 61 | S&F for Gun-metal globe or gate valves of 20mm bore , with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and directed.. |
| 62 | Repair & maintenance of Refrigerator / Water Cooler /deep freezer any capacitycomprising of the following tasks at different location complete all as specified and directed by Engineer-in-Charge.(a) Inspecting, taking down, brushing cleaning with blower including acid/detergent wash of condenser and cooling coil.(b) Carry out operation of blower and compressor and ensure that satisfactory functioning of all parts.(c) Inspecting the leakage in the system.(d) Checking of the earth continuity of electrical parts.(e) Checking the functioning of thermostat.(f) Inspection of all electrical parts.(g) Testing the machine for satisfactory operation.(h) Check and correct all electrical wiring & test its functioning(j) Testing of Refrigeratorafter repair. |
| 63 | Supply & Fixing in replacement of thermostat switch suitable for water cooler 40/80 as required at site complete all as specified and directed. |
| 64 | Supply and Fixing in replacement fan motor capacitor2.5/3.15mfd complete all as specified and directed. |
| 65 | Supply & fixing in replacement of starting relay as requiredat site for water coolers 40/80 Ltrs capacity complete including connecting, testing complete all as specified and directed. |
| 66 | M & L for Disconnecting & taking out compressor (\"R type) from water cooler for any capacity and supply and fix the new compressor including flushing dehydration and gas charging complete all as specified and directed. |
| 67 | M & L for replacement of unserviceable sealed compressor with new hermetic sealed compressor of existingmake including charging of refrigerant gas and testing on full load complete all as specified and directed. |
| 68 | M & L for replacement of unserviceable compressor with new compressor of existingmake including charging of refrigerant gas and testing on full load complete all as specified and directed. |
| 69 | Taking down desert cooler of any size by disconnecting electrical supply, cleaning, oiling of all moving part of pump & exhaust fan/kit, Replacing PVC pipes, nozzles, distributors, pads, checking electrical connections complete all as specified and directed. |
| 70 | Material and labour in replacement of wood pads(set of three)as per sample complete all as specified and directed. |
| 71 | Material and labour in replacement the new desert cooler pump.including testing for proper functioning complete all as specified and directed. |
| 72 | Material and labour in replacement the new exhaust fan kit with leg assembly 450mm sweep complete all as specified and directed. |
| 73 | Material and labour in replacement the new exhaust fan motor with leg assembly 450mm sweep complete all as specified and directed. |
| 74 | Material and labour in replacement the new exhaust fan blade 450mm sweep, complete all as specified and directed. |
| 75 | Material and labour in replacement new body of desert cooler of 600 x 600 x 900 mm size or in next higher size in volume duly painted of 20 SWG sheet with 22 SWG flops, front grill, PVC pipe, nozzle,selector switches,swinging motor,distributor and nut bolts washers for fixing fanclamps, complete all as specified and directed. |
| 76 | Material and labour front grill of desert cooler as per sample complete all as specified and directed. |
| 77 | Material and labour for PVC flexible distributor heavy duty with nozzle as per sample complete all as specified and directed. |
| 78 | M&L PVC insulated FRLS single core with strandard copper cable of size 4 Sqmm in two run and 4 Sqmm one run for earth and drawing through existing concealed conduit including taking down old UNSV cable complete all as specified and directed.Note :- 2 runs of 4 Sqmm cable and one run of 4 sqmm cable will be measured as one running meter for the purpose of measurement and payment. |
| 79 | Material and labour in repairs,Single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 20 Amp, complete all as specified and directed. |
| 80 | Material and labour in replacement of 3 pin socket metalic plug top industrial type complete all as specified and directed. |
| 81 | Material and Labour for servicing of split type AC\"s of capacity 1.5/2 TR comprising of the following tasks installed at different locations includingtesting complete all as specified and directed by Engineer-in-Charge. (a) Inspecting and checking the Indoor/outdoor units for noise free operation.(b)Checking the electrical connection for tightness(c) Cleaning the condenser with cleaning agent followed with pressurized water and cleaning the cooling coil with air blower with water pressure gun.(d) Greasing/Oiling of condenser fan motor and blower motor.(e) Checking for any refrigerant leakage by pressure testing and repair it.(f) Checking for serviceability of remote control unit and replace with new battery. |
| 82 | Material and Labour for servicing of 5.5 TR chiller comprising of the following tasks at different locations including Refixing, commissioning and testing complete all as specified and directed by Engineer-in-Charge.(a) Inspecting, taking down, brushing cleaning with water pressure gun including acid/detergent wash of condenser and cooling coil.(b) Carry out operation of blower and compressor and ensure that satisfactory functioning of all parts.(c) Inspecting the leakage in the system by pressure test and repair it.(d) Checking of the earth continuity of electrical parts.(e) Checking the functioning of thermostat.(f) Inspection of all electrical parts.(g) Testing the machine for satisfactory operation. |
| 83 | Material and Labour for repair to leaking area of split type AC unit of capacity 1.5/2 TR capacity including nitrozen pressure testing, dehydration and any type ofgas charging complete all as specified and directed. |
| 84 | Material and Labour for repair to leaking area of window type AC unit of capacity 5.5 capacity including pressure testing, dehydration and any type ofgas charging complete all as specified and directed. |
| 85 | Supply and charging Refrigerant(R410,R32,R134 and existing refrigerent) to any type of AC unit including CFC free and non CFC Free AC complete all as specified and directed. |
| 86 | Supply and fixing in replacement of starting relay 25 Amps for split type AC units of capacity 2 /1.5TR as required at site complete all as specified and directed. |
| 87 | Supply and fixing in replacement of start run capacitor 45/60 MFD for split type A/C\"s of capacity1.5/2 TR complete all as specified and directed. |
| 88 | Supply & fixing in replacement of running capacitor 6 mfd for blower motor as required at site complete all as specified and directed. |
| 89 | Taking out and replacement ofcondenser fan motor DC of split type AC 1.5/2 ton units of capacity 1.5/ 2 TR complete all as specified and directed. |
| 90 | Taking out and replacement ofcondenser fan motor AC of split type AC units of capacity 1.5/ 2 TR complete all as specified and directed. |
| 91 | Material & Labour for Fixing the new blower motor DC in replacement of for split type A/C unit as per existing model complete all as specified and directed. |
| 92 | Supply & Fixing the new blower motor AC for split type A/C unit as per existing model complete all as specified and directed. |
| 93 | Supply and fixing in replacement of new blower motor for window ac as required at site single phase 230 volts double shaft with clamp bolts, nuts and rubber bushes including testing & commissioning complete all as specified and directed. |
| 94 | S&F in replacement the new swing motor as per existing model/make for split type AC 1.5/2TR unit complete all as specified and directed. |
| 95 | Supply and fix out door fan blade in existing model complete all as specified and directed. |
| 96 | Material and Labour for replacementof defectiveelectronic components / IC Circuits of PCB card with display unit suitable of 1.5/2 ton split ACindoor unitas required on site including replacement of defectiveelectronic components / IC Circuits, complete all as specified and directed. |
| 97 | Material and Labour for replacement PCB card suitable of 1.5/2 ton inverter split ACas required on sitecomplete all as specified anddirected by Engr-in-Charge including sensorcomplete all as specified and directed. |
| 98 | Material and Labour for replacement PCB card suitable of 1.5/2 ton window as required on sitecomplete all as specified anddirected by Engr-in-Charge including sensor complete all as specified and directed. |
| 99 | Disconnecting and taking down burnt condenser coil of capacity 1.5TR from split type AC unit and Supply and Fix new copper condesor coil as per existing model complete including testing complete all as specified and directed. |
| 100 | Materal and Labour for replacement ofcooling coil assembly complete suitable for1.5 / 2 tonindoor unit Split type ACincl testing for satisfactory working condition acomplete all as specified and directed. |
| 101 | Disconnecting and taking down burnt compressor of capacity 1.5TR from split type AC unit and Supply and fix new one as per existing model complete including testing complete all as specified and directed. |
| 102 | Disconnecting and taking down burnt compressor of capacity 2TR from split type AC unit and Supply and fix new one as per existing model complete including testing complete all as specified and directed. |
| 103 | Labour for dismantling of Split AC 1.5/2 ton complete unit from the existing place complete all as specified and directed. |
| 104 | Labour for fixing of Split AC 1.5/2 ton including masonary work complete unit complete all as specified and directed. |
| 105 | Material and labour install wall mounted stand for mounting indoor unit of split AC complete with all fixing arrangement complete all as specified and directed. |
| 106 | Material and labour wall mounted stand for mounting outdoor unit of split AC complete with all fixing arrangement complete all as specified and directed. |
| 107 | M&L in repairs copper tubing 3/8” outer dia suitable for AC 2TR capacity complete all as specified and directed. |
| 108 | All as per item No 107 but 5/8” outer dia. |
| 109 | Material and Labour for providing insulation 9mm thick for dia 1/4\",3/8\",1/2\",5/8\",6/8\" copper tubing’s from Indoor to outdoor units with foam insulation followedwith clamps complete all as specified and directed. |
| 110 | Material and labour for the new remote with battery as per existing model for 1.5/2 TR split type A/C unit complete all as specified and directed. |
| 111 | Material and labour in replacement ofwall mounted Voltage stabilizers 4/5 KVA single phase,230 Volts AC,voltage variation between 140- 300,intelligent time delay system,digital display,low and high voltage cut-off system, complete all as specified and directed. |
| 112 | M & L for Taking out unserviceable indoor unit and supply and fix the newindoor unit of 1.5/2 TR capacity split AC 230 Volts single phase including installing ,charging complete all as specified and directed. |
| 113 | M & L for Taking out the unserviceable condensor motorof 5.5 ton AC and S&F thenew condenser motor of 5.5 TR split AC of existing make complete all as specified and directed. |
| 114 | M & L for Disconnecting and taking down burnt compressor of capacity 5.5 TR from ductable split type unit and Supply and Fix new compressor of exsiting make with charging of refrigerent after dehydration testing and vaccummingone as per existing model complete including testing complete all as specified and directed. |
| 115 | Supply and installation of PVC Duct 100 mm width For AC copper pipes and insulation complete all as specified and directed. |
| 116 | M & L for Taking out unserviceable outdoor unit and supply and fix the newOUTDOOR unit of 1.5/2 TR capacity split AC 230 Volts single phase including installing ,charging complete all as specified and directed. |
| 117 | M&L for replacement ofelectronic remote control unit of split type A/C unit (cordless type)1.5 Ton complete of existing makecomplete all as specified and directed. |
| 118 | M&L for replacement ofelectronic remote control unit of split type A/C unit (cordless type)2.0 Ton complete of existing make complete all as specified and directed. |
| 119 | Material and labour in replacement 3 core copper PVC insulated of size 4 Sqmm complete all as specified and directed. |