| 1 | SCHEDULE `A\" PART - I (Building Works) is not prepriced by MES and prepriced rates indicates 0.0 under column 6 signified this fact only. |
| 2 | Construction of Md Accn for block of 20 QTRs (Warrant Officer-10 QTRs + SGT & below - 10 QTRs) with stilt parking and 05 floors including RCC water tank over roof (1 compartment of 25000 litre for fire fighting + 1 compartment of 10000 Ltrs for domestic work) complete all as specified and as shown on drawings. Note :- Lift shall be paid under respective schedule of Lift except civil works required as shown on drawings. |
| 3 | NOTE: Schedule ‘A’ Part IIto XV under Ser No. 2.01to 2.14 are Prepriced by MES. |
| 4 | Lump sum price worked out by the Contractor for “SITE CLEARANCE, EXCAVATION AND EARTH WORK” as listed in Schedule ‘A’Part II |
| 5 | Lump sum price worked out by the Contractor for “INTERNAL ELECTRIFICATION\"” as listed in Schedule ‘A’Part III |
| 6 | Lump sum price worked out by the Contractor for “INTERNAL WATER SUPPLY\"” as listed in Schedule ‘A’Part IV |
| 7 | Lump sum price worked out by the Contractor for \"LIFT” as listed in Schedule ‘A’Part V |
| 8 | Lump sum price worked out by the Contractor for “FIRE FIGHTING” as listed in Schedule ‘A’Part VI |
| 9 | Lump sum price worked out by the Contractor for “LIGHTENING PROTECTION” as listed in Schedule ‘A’Part VII |
| 10 | Lump sum price worked out by the Contractor for \"ROAD, PATH AND CULVERT” as listed in Schedule ‘A’Part VIII |
| 11 | Lump sum price worked out by the Contractor for “EXTERNAL WATER SUPPLY” as listed in Schedule ‘A’Part IX |
| 12 | Lump sum price worked out by the Contractor for “EXTERNAL ELECTRIC SUPPLY” as listed in Schedule ‘A’Part X |
| 13 | Lump sum price worked out by the Contractor for“SEWAGE DISPOSAL ” as listed in Schedule ‘A’Part XI |
| 14 | Lump sum price worked out by the Contractor for“AREA DRAINAGE ” as listed in Schedule ‘A’Part XII |
| 15 | Lump sum price worked out by the Contractor for“DG SET” as listed in Schedule ‘A’Part-XIII |
| 16 | Lump sum price worked out by the Contractor for“ARBORICULTURE(GRIHA)” as listed in Schedule ‘A’Part-XIV |
| 17 | Lump sum price worked out by the Contractor for“DEMOLITION AND DISMANTLING ” as listed in Schedule ‘A’Part XV |
| 18 | SCHEDULE `A\" PART - XVI MISC ITEMSis not prepriced by MES and prepriced rates indicates 0.0 under column 6 signified this fact only. |
| 19 | INTERNAL ELECTRIFICATION |
| 20 | S&F modular metal flush box , 8 module complete all as specified and directed by Engineer-in -charge |
| 21 | Supply and fixed modular MCB single pole 16 Amp complete with modular cover for gyser pointcomplete all as specified and directed by Engineer-in -charge. |
| 22 | Supply and fixed modular mcb double pole 20 Amp complete with modular cover for AC pointall as specified and directed by engr-in-charge. |
| 23 | LIFT |
| 24 | Supply , install test & commission of LT Panel as per latest IS and amendment upto date of suitable size of indoor, Cubicle type, factory fabricated out of MS Sheet of 3.0 mm thick dust, vermin proof, weather proof, IP-54 Grade of protection, fabricated on 50x50x5 mm thick MS angle iron frame both side opening and locking arrangement including providing copper bus bar of capacity 100 Amps rating for 415 V 50 Hz 3 Phase system including with RYB colours and suitable adopter boxes with spreader links for connecting cables with switch terminals (Where necessary)complete with following:-. ( lift room panel Type III) INCOMING(a) MCB TPN 63 Amps 4 pole 16 KA (b) Voltmeter 0-500 volt(c) Amperemeter 0-200Amp(d) LED Indicator set OUT GOING(a ) RCCB 40 A, 10 KA(Lift 13 P)-01 Nos(b ) MCB SPN 32 A, 10 KA - 1 No (Room light)-01 Nos(c )RCCB 40 A, 10 KA (Fire pump)-01 Nos complete all as specified and as directed. |
| 25 | FIRE FIGHTING |
| 26 | S&F hose reel of 20 mm dia and 30 m length conforming to IS 5132 complete all as specified and directed |
| 27 | S&F branch pipe with nozzle for 20 mm dia for hose reel conforming to IS 8090 complete all as specified and directed. |
| 28 | Supply, installing, testing & commissioning of 2x 1.5 sq mm unarmoured PVC insulated FRLS copper conductor cable complete all as specified and directed. |
| 29 | Supply and fix of Talk back systemcomplete all as specified and directed |
| 30 | S & FFire brigade inlet connection 5way complete all as specified and directed. |
| 31 | M& L for self luminous sign\"s board for \" Fire Exit \" fixed on stair case on each floor complete all as specified and directed. |
| 32 | M & L self luminous sign\"s board in case of Fire \"Use Stair case, Do Not Use Lift\"complete all as specified and directed. |
| 33 | Supply installtion testing and commissioninng of Active Repeater Panel with Annunciation repeaters : Supply of Panel with 320 Alpha numeric Characters on LCD display as Network Node on the Main Network Peer-Peer Topology , shall be able to work with all functionality of Main Panel having Reset / Alarm Silence and Acknowledgement Buttons . On the Active Repeater over Serial Interface or Network there shall be Annuciation Panels as well for all Control stations. Individual Active Repeater shall be able to take care of upto minimum 16 nos Annunciation LCD Indicator Panels |
| 34 | Supply and fix6Kgs fire extnguisher Dry , Chemical powder (ABC) type, light weight stored pressure type conforming to IS : 15683 complete as directed. |
| 35 | Supply and fix4.5Kgs fire extnguisher CO2 type, light weight stored pressure type conforming to IS : 15683 complete as directed. |
| 36 | Supply and fix9ltr fire extnguisher mechanical foamtype, light weight stored pressure type conforming to IS : 15683 complete as directed. |
| 37 | LIGHTENING PROTECTION |
| 38 | S&F epoxy base insulators of suitable size 40mm height for fixing GI/aluminium earth strip on wall/ceiling/floor/poles etc. |
| 39 | EXTERNAL WATER SUPPLY |
| 40 | Supply and Fix 10 HP monoblock pump set suitable for 415V, 3 phasewith minimum head of 40 metre and minimum discharge of 711LPM (1+1 working and standby) complete all as specified and directed by Engineer-in -charge |
| 41 | Supply and Fix star delta Starter fully automatic suitable for 10HP, 415 V AC motor with complete protections complete all as specified and directed by Engineer-in -charge |
| 42 | Cutting of existing GI/CI pipe/wall, 150 mm bore dia in position for providing branch connection 80 mm bore GI/CI pipe complete all as specified and directed by Engineer-in -charge |
| 43 | M&L for valve chamber of size 900mmx600mmx1000mm (Internal) with brick masonary 230 mm thick in CM Each 1:6, PCC 1:4:8 type, D2 foundation 75 mm thick, finished fair and even, PCC 1:2:4 type, B1 coping 150 mm thick on top of brick wall for fixing chamber cover, 10 mm thick cement mortar 1:4 plaster on exposed surfaces of brick wall (both internal and external), mild steel cover of 3.15 mm thick inclduding mild steel angle iron 40x40x6 mm size fram fixed to PCC coping with the same size of angle iron hold fast and with necessary handle and locking arrangements, metal surfaces duly painted with black bituminous paint over a coat of red oxide zinc chrome primer and finishing the masonry/concrete surfaces with 3 coats of white wash including necessary |
| 44 | EXTERNAL ELECTRIC SUPPLY |
| 45 | M&L for boring of holes under road/pavement/hard standing by trenchless technology, using ultra sound technique and necessary machine including material and labour for HDPE pipe of 160 mm dia suitable for 04 Kg/cm working pressure. Wall thickness of pipe not less than 6.5 mm for 1.1KV Cable(i) Depth of Trench Less shall not less than 0.45 m from ground level unless other wise specifed due to site requirement and contractor has to maintain the depth of trenchless up to 1 m from ground level if required as per site conditions all rates quoted shall be deemed to be included to maintain the Trench less depth as directed during exection to avoid damages to the existing services(ii) The cost quoted is deemed to be inculded for repairs rectification for damages done to the existing elecrtical communication and water supply system / Sewage System during execution of work. |
| 46 | Supply , fabrication, Testing and Commissioning (including CPRIcertified ), Outdoor type, floor mounted , cubicle type LT panel board as per latest IS Norms and with amendement upto date suitable for 415 volts, 3 phase 4 wire 50 Hz AC supply system having busbar chamber with insulated for the Panel shall be dust and vermin proof IP-66 class protection and made of 3.15 mm, CRCA MS sheet,double door,front and back opening with proper locking arrangement ,lifting lugs,rubber gasket on front and back to make it dust and vermin proof , and 50x50x6MM thick MS angle iron, frame work , Aluminium busbar 200 Amps for 3 phase 4 wire system, powder coated finish over two coat of red oxide primer, including internal wiring with PVC insulated stranded FRLS, copper conductor cable , IS-694 marked , 1100 volts grade of appropriate size (but not less than 4.0 Sqmm ), PCC foundation for mounting of Panel and comprising of following: |
| 47 | INCOMING:-(i) MCCB 4-Pole160 Amp 415 volts AC, 25KA rupturing capacity adjustable thermal type -01 No (incoming)(ii) Analog type Voltmeter 0-500volts square 96mm flush pattern with rotary selector switch - 01 Set(iii) Analog type Amp meter square 96mm flush pattern having range 0-200 Amp with 3 way rotary selector switch and CTs of Suitable range - 01 No(iv) Indicating lamp, LED type (Red ,Yellow, Blue) - 01 No(v)Aluminum bus bar 200 Amp with insulator - 04 Nos(vi) Connection and internal wiring complete - 01 Job |
| 48 | OUTGOINGS:-(i) MCCB TPN 40 Amp 415 volts AC, 16KA rupturing capacity-03No (ii) MCB SPN 20 Amp 415 volts AC, 10KA rupturing capacity-01 No (iii) All incoming & out going feeders shall be connected by cable thgland plates/glands (iv) The various feeders shall be indicated by 50 mm size letters in synthetic enamel white paint. |
| 49 | Supply and fix special purpose metal enclosures forVTPN suitable for MCCB upto 100 Amps as incomer distribution board 415Volts optium F1+12, 4 way double door IP-54 protection includingflushing the DBs inside the walls and making good the disturbed surface also matching with the existing surface complete all as specified and directed by Engineer-in-Charge. |
| 50 | M&L for LT Pole box for security/Street light weather proof made out of PVC fire retardant non fusing sock and dust proof one piece molded SMC base and SMC cover with hinged door all mounting type comprising of aluminium 25Ampbus bar with MCB SP 10 amp of size 300x200x100mm, fixed on pole with MS clamps 20x3mm with necessary nuts, washers and incl applying two coats of synthetic enamel paint over red oxcide primer on steel surface/clamps and embrossing/painting of danger sign ofsize not less than 10cmsX7.5 cms with letter and conventional skull and bones in signal red colour on front face of kisko box complete all as directed. |
| 51 | S&F street light GI pipe bracket 40 mm dia 1.2 metre length (ISI marked) light grade bend to shape with two Nos MS clamp duly painted nuts and bolts etc complete all as specified and directed by Engineer-in-Charge. |
| 52 | DG SET |
| 53 | Supply and installation, commissing and testing silent diesel engine driven Gen set 40 KVA capacity 415 volts, 3 phase, 4 wire acoustic weather proof enclosure as per latest CPCB-IV norms and noise level shall not execeeding 75 db at a distance of 1 meter.Engine as per IS:10001/ 10002 and Alternator as per IS: 13364 installed on PCC platform as per manufacture recommendation complete complete comprising the following components. (a)Diesel Engine :- Diesel engine develping suitable BHP, 1500 RPM water cooled engine inclusive of the following standard accessories (i) Spider coupling guard (ii) Fly wheel (iii) Fly wheel housing complete with starter gear ring and coupling (iv) Fuel pipe (v) Air cleaner (vi) Fuel & Lub oil filter (vii) by pass filter (viii) Lub oil pump (ix) Electric starter 12 Voits DC (x) Battery charging generator (DC alternator) (xi) Industrial silencer (xii) Lub oil cooler (xiii) Flexible pipe for silencer (xiv)DC voltmeter (xv) Lub oil pressure gauge, lub oil/water temperature guage (xvi) Speedo meter and engine running hours meter (xvi) Display for fault(xvii)Governor (xviii)Battery as per manufacture recommendation-01 No. |
| 54 | (b) ALTERNATOR : Alternator suitable for continuous operation generation 40 KVA 1500 RPM 415 V at NTP, 0.8 power factor 3 phase, 50Hz, self excited and regulated with at ball/ roller bearing confirming to IS - 4722 (c) AMF PANEL (in built in canopy) AMF panel, factory made, indoor, cubical type, front open able fabricated out of CRCA sheet 2 mm thick complete with 4- pole Aluminium Bus, MCCB, Power contractor, Relay, battery charging system and protection as per OEM specifications. (d) Acoustic enclosure with natural air circulation without loss of any power for ventilation fan the enclosure shall be modular in construction with hinged bolted structure to provide easy dismantling and shall be made out of high quility CRCA sheet of 2 mm thickwith sufficient accessories for maint work, interior lighting arrengement 01 Nos LED light fitting of rating as per manufacturer specification with ON/OFF switch.(e) Fuel tank as per manufacturer recommedation with inlet and outlet connections and fuel level indicator (f) Base frame made out of suitable MS channel duly reinforced and provided with adequate numbers of anti-vibration pads (f) Foundation as per design of manufacturer to be provide by contactor within overall quoted rate. |
| 55 | ARBORICULTURE (GRIHA) |
| 56 | Supplying and stacking of good earth brought from outside MOD land of any lead at site including royalty and carriage complete all as specified and directed by Engineer-in-Charge. |
| 57 | Supplying and stacking at site dump sludge manure from approved source including carriage at work (a) screened through sieve of 1.5 designation 4.75mm complete all as specified and directed by Engineer-in-Charge. |
| 58 | Digging holes in ordinary soil and refilling the same with excavated earth mix with manure or sludge in ratio of 2:1 by volume (2 parts of stacked volume of earth after reduction by 20% : 1 part of stacked volume of manure after deduction by 8%) flooding with water, dressing including removal of rubbish and surplus earth if any with all leads for holes 90cm dia and 90 cm deep complete all as specified and directed by Engineer-in-Charge. |
| 59 | Supply of the plant at site including all transportation charges including complete operation of plantation (shaded trees) Botanical name (common name) overall height stem size as follows :- |
| 60 | EVERGREEN TREES |
| 61 | CHUKRASIA TABULARIS (CHAKRASIA) overall height 3-5 feet stem size 6-8 cm |
| 62 | ALSTONIA SCHOLARIS (ALSTONIA) overall height 3-5 feet stem size 6-8 cm |
| 63 | ALSTONIA SCHOLARIS (ALSTONIA) overall height 3-5 feet stem size 6-8 cm |
| 64 | ALSTONIA SCHOLARIS (ALSTONIA) overall height 3-5 feet stem size 6-8 cm |
| 65 | Lawn (grassing) supply and plantation of grass selection No 1 by dibbling root method Note - Following activities/works to be carried at site for plantation of grass selection No 1 (i) Ploughing of whole site in ordinary soil upto depth of 30cm and removing unwanted material such as stone, weeds, trees roots etc. which are not suitable for healthy growth of grass (ii) Dressing and levelling of soil to a required gradient and slope after loosening of soil (iii) Mix and spreading of good earth, manure and fertilizer as directed (iv) Fine dressing the ground to required slope and gradient towards the manhole (v) Grassing with specified grass including watering unit establishment of the lawn (vi) Final levelling by spreading sand and good earth mixture, manuring as and when directedby the Engr-in-charge. |
| 66 | Supply and laying of concrete grass pavers of size 400 x 300 x 60mm thick complete all as specified and decided by the Engr-in-charge. |
| 67 | DEMOLITION AND DISMANTLING |
| 68 | Demolition of mud fuska complete all as decided by the Engr-in-charge. |
| 69 | Taking up old underground cable of any size complete all as decided by the Engr-in-charge. |
| 70 | Dismentling old unserviceable busbar complete all as decided by the Engr-in-charge. |
| 71 | Taking up old unservicable earthing completed complete all as decided by the Engr-in-charge. |
| 72 | Taking down carefully by unscrewing of old unserviceable lamp holder complete all as decided by the Engr-in-charge. |
| 73 | Taking down of old unserveable Tubelight and led of any wattage and removing material to store for safe custody. |
| 74 | Taking down of old unserviceable exhaust fan metal and removing material to store for safe custody. |
| 75 | Taking down of old unserviceable exhaust fan plastic and removing material to store for safe custody. |
| 76 | Taking down of old unserviceable gyser and removing material to store for safe custody. |
| 77 | Diconnecting of smart electric metre and removing to store for safe custody and refixing the same after construction of building. |
| 78 | Note :-Schedule of credit will be deducted from total quoted amount while calculating contract sum. |