Sales : +91-777 804 8217
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 17-02-2026 | Revised Tender Pages | Other | 27-02-2026 |
| 2 | 17-02-2026 | Revised BOQ | Other | 27-02-2026 |
| 3 | 17-02-2026 | Revised BOQ | BOQ | 27-02-2026 |
| Sl. No. | Item Description |
| 1 | B & R Division Items |
| 2 | Demolition of un-reinforced cement concrete in ground floor and paving not exceeding 15 cm thick (below or above ground level) complete all as specified and directed. |
| 3 | Demolition of brick work or stone/ boulder masonry, built in cement mortar including all quoins, pillars etc. complete all as specified and as directed. |
| 4 | Dismantling floor, hearth or wall tilling including cement mortar bedding (but not backing) removing serviceable tiles to stores and rubbish off the premises. |
| 5 | Demolition of reed lathing, single or double including battens and plaster or chiken wire lathing all as specified. |
| 6 | Dismantling mild steel work or wrought iron of any description and in any position complete all as specified and as directed. |
| 7 | Dismantling plain or corrugated steel sheeting, any gauge or any thickness as in roof covering, wall cladding, etc.including all necessary staging / scaffolding, etc. as required complete all as specified and as directed. |
| 8 | Dismantling wall and ceilingboards (fibre, pulb, insulation etc) or insulation boards slabs/blankets any thickness including cover fillets all as specified and as directed. |
| 9 | Dismantling wooden boarding (eaves board, purlin, rafter etc) of any description fixed in any position with nails complete all as specified and as directed |
| 10 | Dismantling of timber fillets rails, posts, rafters, pulins etc under 40 sqcm in setion in any position in unframed work complete all as specified and directed. |
| 11 | Dismantling of timber scantling 40 Sqcm and over in section, in any position in unframed work complete all as specified and directed. |
| 12 | Dismantling of timber scantling 40 Sqcm and over in section, in any position in framed work complete all as specified and directed. |
| 13 | Dismantling asbestos cement/PVC pipe 50/75/100 mm dia including clamps complete all as specified and directed. |
| 14 | Dismantling of rain water/sewage pipe of any type and any size including fitting complete all as specified and as directed. |
| 15 | Taking down cement plaster on brick or stone walls etc, including raking out joints, hacking for key scrubing down with water etc complete all as specified and as directed. |
| 16 | Taking down wooden shutters of size not exceeding 1.0sqm and disposing off complete all as specified and directed. |
| 17 | Taking down wooden shutters of size exceeding 1.0sqm but not exceeding 2.0sqm and disposing off complete all as specified and directed. |
| 18 | Taking down chowkhats or frame with shutters (without taking off shutters from frame) each not exceeding 1.50 Sqm each complete all as specified. |
| 19 | Taking down Chowkats or frames with shutters exceeding 1.5 Sqm but not exceeding 4 Sqm each (without taking off shutters from the frame) complete all as specified. |
| 20 | Taking up or down 15mm diaGI steel tubing and connections, including cleaning for refixing or removal to store complete all as specified and as directed. |
| 21 | Taking up or down 20mm diaGI steel tubing and connections, including cleaning for refixing or removal to store complete all as specified and as directed. |
| 22 | Surface dressing n exc 15 cm deep and gettingout in soft / lose soil complete all as specified |
| 23 | Excavating in post holes each n exc 0.5 cum, getting out, in soft /loose soil, ramming earth filling or borken rubble mixed with earth around in layers nexc 25 cm watering and removing ssurfaces soil to distance nexc 50 m and making good surfaces all as specified and directed. |
| 24 | M & Lfor plain cement concrete 1:3:6 type C-2 (using 40mm graded stone aggregates) as in foundations, sub-base,filling and mass concrete. all as specified and dirceted |
| 25 | M & Lfor Plain Cement Concrete(1:3:6) type C1 using 20mm graded stoneaggregate as in surface channel and drainall as specified and directed. |
| 26 | Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred/stopped ends foretccomplete all as specified and directed. |
| 27 | Add or deduct for each 25 mm girth or part thereof over or under 30cm(For adjustment in girth of item mention above) |
| 28 | M & Lfor 75mm thickcement concrete 1:3:6 type C2 (using 40mm graded stone aggregate) as in plinth protection finished even and fair without using extra cement laid inpanels and joints filled with bituminous mastic filling with 1 part of bitumen and 3 part of sand complete all as specified and directed. |
| 29 | M & Lfor 100mm thick plain cement concrete 1:3:6 type C-2 (using 40mm graded stone aggregates) as in base in floor fair and even complete all as specified and dirceted |
| 30 | M & L for plain cement concrete 1:2:4 type B1 using 20mm graded aggreagate as in coping , benching incl necessary formwork complete all as specified and directed. |
| 31 | M & L sand filling under floors or in foundation , base for precast concrete interlocking paver block including watering levelling and consolidation complete all as specified . |
| 32 | M & LProviding and laying 60mm thickness factory made precast concrete interlocking paver block of M-35 grade any size and shape confirming to IS 15658-2006 with approved colour, design & pattern as in footpath, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over and 50mm thick compacted bed of coarse sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with fine sand and cutting of paver block as per required size and pattern, finishing and sweeping extra sand; complete all as specified & as directed.Note : Item of Sand filling will be paid seperatly in relevant item. |
| 33 | M & Lfor 10mm dia and over TMT bars, cut to length bend to shape as required including cranking, hooking etc and binding with and including mild steel wire (annealed) not less than 0.9 mm dia complete all as specified and directed. |
| 34 | M & Lfor 6mm to 8mm dia and over TMT bars, cut to length bend to shape as required including cranking, hooking etc and binding with and including mild steel wire (annealed) not less than 0.9 mm dia complete all as specified and directed. |
| 35 | M & Lfor Mild Steel TMT Bar 6mm dia and over up to 10 mm dia as in stirrups, spacers and binders as required including cranking, hooking etc and binding with and including mild steel wire (annealed) not less than 0.9 mm dia complete all as specified and directed |
| 36 | M & L for brickwork with subclass \"B\" or locally available best qualityold size bricks, straight or curved on plan exc 6 m mean raduis,built in CM (1:4) complete all as specified and directed. |
| 37 | M & L for half brick work in cement mortar (1:4) straight or curved on plan to any radius with locally available Subclass ‘B’ old size best quality bricks all as specified . |
| 38 | M & L10mm thick rendering in cement mortar (1:6) on any face of brick walls or concrete surfaces, finished even and smooth without using extra cement complete all as specified. |
| 39 | M & Lrendering 10mm thick cement plaster on other than fair faces of brick wall or condrete surfaces in CM (1:6) finished fair and even complete all as specified. |
| 40 | M & Lfor 10 mm thick rendering in cement mortar (1:6) on other side of lathing surface finished fair and even complete all as specified. |
| 41 | M & Lfor 15 mm thick renderingin cement mortar 1:4 on fair faces of brick wall or concrete surfaces, finished the surfaces even and fair without using extra cement complete all as specified. |
| 42 | M & Lrendering 15 mm thick cement plaster in two layer each of 10+5 mm thick on one side of lathing in CM (1:4) & water proofing compound mixed with second layer @ 3% finished fair and even complete all as specified. (Note :WPC measured separately). |
| 43 | M & Lrendering 15 mm thick cement plaster in two layer each of 10+5 mm thick on fair faces of brick wall or condrete surfaces in CM (1:4) & water proofing compound mixed with second layer @ 3% finished fair and even complete all as specified. (Note :WPC measured separately). |
| 44 | M & Lfor Rendering/plastering, 15 mm thick (10mm+5mm)in two layers in cement mortar (1:4) on any face of brick walls or concrete surfaces, using WPC, surfaces finished finished even and smoothwithout using extra cement complete all as specified. (Note :WPC measured separately). |
| 45 | Supply only Liquid water proofing compound (ISI marked) complete all as specified and directed. |
| 46 | Supply only integral water proffing compound WPC complete all as specified. |
| 47 | M & Llight shade Vitrified Ceramic tiles 8 to 10 mm thick (square/ rectangular) polished, area of each tiles exceeding 0.18 Sqm and not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tile including15 mm thick screed bed or bedding layers in cement mortar 1:6completeall as specified and directed. |
| 48 | M & Llight shade Vitrified Ceramic tiles 8 to 10 mm thick (square/ rectangular) polished, area of each tiles exceeding 0.18 Sqm and not exceeding 0.36 sqm as in skirting including10mm thick screed bed or backing coat in cement mortar 1:4layingof skirting/dado on walls all as specified and directed. |
| 49 | M & LNon Skid ceramic tiles colour7 to 8mm thick (square/rectangular) area of each tile exceeding 0.11 but not exceeding 0.18 sqm, as in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tile including15 mm thick screed bed or bedding layers in cement mortar 1:6overbrushing with neat cement slurry as specified |
| 50 | M & LNon skid Ceramic tiles7 to 8 mm thick (square/ rectangular) , area of each tiles exceeding 0.18 Sqm and not exceeding 0.38 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over & including15 mm thick screed bed or bedding layers in cement mortar 1:6 completeall as specified and directed. |
| 51 | M & LNon skid Ceramic tiles7 to 8 mm thick (square/ rectangular) , area of each tiles exceeding 0.18 Sqm and not exceeding 0.38 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over & including15 mm thick screed bed or bedding layers in cement mortar 1:4 completeall as specified and directed. |
| 52 | M & LNon skid Ceramic tiles7 to 8 mm thick (square/ rectangular) , area of each tiles exceeding 0.18 Sqm and not exceeding 0.38 sqm as in skirting including15mm thick screed bed or backing coat in cement mortar 1:6layingof skirting/dado on walls all as specified and directed. |
| 53 | M & LGlazed ceramic coloured tilesin vertical surface size 350 x 250 x 7mm/450mm x 300mm x & ( 6mm to 7mm )mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match over & including10mm thick screed bed or backing coat in cement mortar 1:4layingof skirting/dado on walls all as specified and directed. |
| 54 | Supply and fix pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified. |
| 55 | Supply and fix pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified. |
| 56 | S & F of mild steel rolled sections (Fe-290, Gde E-165) as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and other misc brackets; fixed with angle cleats for fixing of eaves board or other connecting plates complete all as specified. |
| 57 | Supply and fix structural steel work in tubular/hollow sections trusses , Purlin , posts, rafteretc including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to IS 1161-1979 grade St.-240 complete all as as specified and directed. |
| 58 | Supply and fix MS screw bolts (machine made ) with hexagonal or square heads at one end & screwed the other or screwed both ends ,each screwed end to be fitted with washers & one hexagonal or square nutlength of bolt n exc 10 cm long dia 11 to 15mm complete all as specified & as directed. |
| 59 | Supply and fix Framed work such as grills, gratings, etc.. with ends of bars or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165 complete all as specified and directed. |
| 60 | Supply and fix Bands, straps, supports or stays for rainwater, ventilating pipes, including bolts, if required: hooks (stay), heavy, for large gates; hook and pintle hinges large hasps and staples; chains; hand made slidingbolts; clamps; hold fasts; wall ties; hooks for hanging fans; plain angle cleats for securing purlins to wood trusses or rafters; knee piece inserts; two way and three way straps, plate washers,hold fasts, bands, straps, wall ties, plain angle cleats, eaves board frame and similar articles conforming to Fe-290 Gde-E-165 completeall as specified and directed. |
| 61 | S&F for GI wire netting 0.71 mm dia and 12 mm mesh lathing to wood or metal studding joints etc in walls ceiling stanchion,beams etc included all laps cutting and wastes complete all as specified and directed. |
| 62 | S & F Solid PVC door frame of size 50 mm x 47 mm made of 5 mm plain colour PVC sheet reinforced with mild steel square tube complete all as specified in clause 8B.3.1 and shown on page 150 of MES Schedule Part-II (2010). |
| 63 | S & F Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of MS tubes for top & bottom rails, MS frame covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20 mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; paneling of plain colour PVC sheet to be fitted in the MS frame welded/sealed to the stiles & rails with suitable PVC sheet beading and jointed together with solvent cement, supply and fixing in the frame at site as per clause 8 B.2.1 of MES schedule Part-II (2004) complete all as specified. Make: Rajshri or equivalent as approved. |
| 64 | M & LSecond class hard wood as in 35 mm thick Plain, framed,panelled shutters (any number of panels), with panels of timber flat on both sides (feather edged), or of veneered particle board medium density, wood particle board with commercial face veneers: supplied and fitted to chowkats complete all as specified & directed . |
| 65 | S&F 2nd class hard woodglazed andskeletonventilator/ window 30 mm thick open rebated and prepared to receive glass, wiremesh gauge etc (without sash bars), edge of framing plain chemfered rounded fitted with cut and mitred beds for securing glass etc size of members size of members of shutter as specified in SSR part I section 8 clause 8.20(b) complete all as specified and directed. |
| 66 | S&F 2nd class hard woodglazed andskeleton door shutters 35 mm thick open rebated and prepared to receive glass, guage etc (withoput sash bars), edge of framing plain chemfered ro rounded fitted with cut and mitred beds for securing glass etc size of members of shutter as specified in SSR Part I section 8 clause 8.20(a) |
| 67 | S & F 35 mm thick Flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides, smooth finish with lipping of teak wood on edges all as specified and directed |
| 68 | M & Lsmall article of 2nd class hardwood, such as hinge blocks, door and window stops, articles not exceeding 200 cubic centimeter each and fixed with steel screws complete all as specified. |
| 69 | M & L for 2nd class hardwood fillets square, rectangular or tringular in section wrought screwed with nails exc 6 sqcm and n.exc 13 sqcm complete all as specified. |
| 70 | M & L for 2nd class hardwood fillets square, rectangular or tringular in section wrought, fixed with screwed exc 13 sqcm and n.exc 25 sqcm complete all as specified. |
| 71 | M & L for second class harwood fillets square, rectangular or tringular in section clean sawn, fixed with screwed exc 13 sqcm and n. exc 25 sqcm complete all as specified and directed. |
| 72 | M & L for second class harwood plain fillets square, rectangular or tringular in section wrought, bull nosed, splayed, chamfered or rounded on one edge or face, sectional area exc 6sqcm but not exc 13 sqcm complete all as specified and directed. |
| 73 | M & L for second class harwood 50mm thick boarding, wrought, fixed with nails in any position (except flooring and skirting) with butt joints complete all as specified and directed. |
| 74 | M & Lfor Second class hardwood in scantlings timber unframed and fixed for wrought in section completeall as specified and directed. |
| 75 | M & L for second class harwood in scantlings timber framed and fixed for wrought in section complete all as specified and directed. |
| 76 | S&F Steel windows with side hung shutters including box type hinges with steel handles, 100mm long peg stay complete with glazing bars, dovetailed or welded, including locking arrangements complete all as specified directed. |
| 77 | S&F Steel windows with side hung shutters including box type hinges with steel handles, 100mm long peg stay complete without glazing bars, dovetailed or welded, including locking arrangements complete all as specified directed. |
| 78 | S&F Steel ventilator with top hung shutter including hinges, steel peg stay, lugs as in hold fast with locking arrangements, complete all as specified. |
| 79 | Supply and fixStainless steel wire cloth. 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples complete all as specified. |
| 80 | S&F 3.00 mm thick sheet glass ordinary quality and glazing with oil putting square nexc 0.5 sqm in each pane complete all as specified. |
| 81 | S & F Pressed steel frames made of 1.25mm thick MS sheet of profile 105x60mm for door and window frames with one or more rebates includinghinges (100/50mm stainless steel),lock strike plate, shock absorber, 20mm dia 60mm long MS conduit for housing of a drop bolt, treating of internal surfaces of chowkhats with coal tar or black paint including hinges, hold fasts/lugs etc complete all as specified. |
| 82 | S & F Pressed steel frames made of 1.25mm thick MS sheet of profile 125x60mm for door and window frames with one or more rebates includinghinges (100/50mm stainless steel),lock strike plate, shock absorber, 20mm dia 60mm long MS conduit for housing of a drop bolt, treating of internal surfaces of chowkhats with coal tar or black paint including hinges, hold fasts/lugs etc complete all as specified. |
| 83 | M & LCement concrete (1:3:6), type C-0 using 12.5mm graded stone aggregate as in filling of steel chowkhatsand concrete for fixing of holdfast including necessary form work complete all as specified. |
| 84 | S&F Powder coated aluminium (minimum thickness of powder coating 50 micron)for Door shutters with frame, Three track sliding windows ( 2 x glazed & 1 x Gauzed shutter), ventilator & cup boardincluding necessary jointing cleats, screws etc & fixed complete all as specified & directed. |
| 85 | Supply and fix 250mm long Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixedcomplete all as specified. |
| 86 | Supply and fix Aluminium anodised, 200mmbarrel tower bolts of extruded section and fixed complete all as specified. |
| 87 | Supply and fix aluminium handles, fabricated type, anodised 125 mm long fixed with screws complete all as specified and directed. |
| 88 | Supply and fix 75 mm size stainless steel butt hingesmedium weight complete all as specified & directed. |
| 89 | Supply and fix 100 mm long aluminium handles cast type anodised complete all as specified & directed . |
| 90 | Supply and fix 150 mm long aluminium handles cast type anodised complete all as specified & directed . |
| 91 | S&F 100mm long Butt hinges, extruded aluminium alloy with galvanised mild steel hinge pin, anodised and fixed complete all as specified and directed. |
| 92 | Supply and fix 150 mm long aluminum anodised barrel tower bolts of extruded section completeall as specified and directed. |
| 93 | S&F as in repairs 25 mm dia and 1mm thick MS chromium platedcurtain rods with fixing side fancy type brackets end knobs & steel screws etc all as specified and directed . |
| 94 | Supply and fix in repairVitreous China urinals, bowl type urinal flat back large size of 465mm x 355mm x 265mm white (minimum), with grating and union for discharge pipe (back or corner wall type), complete including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement; fixing automatic flushing cistern with brackets, flush pipe, grating and Union for discharge pipe (Exclusive of fixing supply pipe to flushing cistern, trap and waste pipe) complete all as specified and directed. |
| 95 | S &F Vitreous China urinals, bowl type urinal flat back, size of 465 x 355 x 265 mm white (minimum), with grating and union for discharge pipe (back or corner wall type), complete including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement; fixing automatic flushing cistern with brackets, flush pipe, grating and Union for discharge pipe. (Exclusive of fixing supply pipe to flushing cistern, trap and waste pipe) |
| 96 | Supply and fix, as in repair,vitreous china wash basin, white flat back size 550 x 400 mm, excluding taps, waste chain, plug and porcelain stopper but including cp coupling, brackets, cutting for and pinning in ends of bracket or erecting stand complete all as specified. |
| 97 | S&F for in repair vitreous china wash basin, white, counter top, size 560 mm x 461 mm ovel shape including waste coupling but excluding taps, waste chain and plug and porcelain stopper complete all as specified and directed.Make: Hindware Cat Part No 10017 or equivalent as per make approved list. |
| 98 | Supply and fix in repair vitreous china Squatting pan, \"Orissa\" pattern, Size 580 X 440mm ,with integral foot rests (excluding flushing ciestern and flush pipe) incl necessary lime concrete and 100 mm bore cast iron \"P\" trap with 550 to 600mm long neck for connecting WC to branch piece with cement joints complete all as specified & as directed . |
| 99 | Supply & Fixed inrepairsVitreous china wash down water closet pan ( pedestal pattern ) , whitewith P or S trap incl. seat cover but excluding fixing bolts, flushing cistern and flush pipe complete all as specified and as directed. |
| 100 | S & F in repairsPVC valveless,syphonic action type,low level flushing cistren 10 ltr capacity ISI Marked incl all acessories and 32mm dia PVC flush / discharge pipe incl float valve, inlet complete all as specified. |
| 101 | Supply and fix PVC connections 15 mm size with PTMT nuts of length 450 m complete all as specified. |
| 102 | S & F in repairs 15mm bore pillar tap cast copper alloy with capstan head,chromium plated concealed screwed down high pressure with or without hot or cold with long shunk screwed shanks and fly nuts screwed for iron pipes and connecting to water pipe line complete all specified and directed. |
| 103 | S&F in repairs 15mm bore bib taps fancy type, long neck, cast copper alloy, chromium plated, screwed for iron pipe or for brass ferrule including accessories complete all as specified and directed. |
| 104 | Supply and fixin repairs 15mm bore stop valves/angle valveof cast copper alloy, screwed down, high pressure with crutch or butter fly handle, fancy type, chromium plated, with long shank and cup (concealed type) fixed complete all as specified. |
| 105 | S&F in repairs Health faucet (ABS Body) mild steel chromium plated suitable for 15 mm dia pipe with 1.25 metre long flexible tube and ABS wall hook including making connections and fixed in position complete in all respect as specified |
| 106 | S&F in repair PVC connections 15mm dia size with PTMT nuts of length 450mm |
| 107 | Supply & Fixed in repair Brass Chromium Plated bottle traps for wash basins with inlet and outlet screwed for pipe or connections including necessary packing, union and cap and fixed complete all as specified. |
| 108 | Supply and fix as in repair, Tubular towel rail (Aluminium anodised), 20mm dia, D type, 60cm long between flanges complete all as specified and directed. |
| 109 | S&F as in repairs 600mmx450mm bevelled edge mirror of selected quality glass, mounted on 6mm thick AC building board or commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers complete all as specified and directed. |
| 110 | Supply and fix Towel rail, 20mm dia brass chromium plated, 600mm long with fancy type brass chromium plated brackets on both sides and fixed with steel screws and wooden/rawl plugs as in repair complete all as specified. |
| 111 | Supply and fix 125mm dia CP brass shower rose with swivel joints, any colour including shower arm 15mm dia, 195mm long with bend of 45 degree with flange of CP brass as in repair complete all as specified. |
| 112 | S&F of Corner /glass shelf complete all as specified and directed. |
| 113 | M & Lfor providing and applying wall care putty in two coats of 1 mm thickness over plastered surface to prepare the surface even and smooth. |
| 114 | M & Lfor suspended false ceiling using E-grid 2430, 180 GSM (exposed ceiling suspension system ) of grid size 600mmx600 mm with main runner 38 mm x 24 mm and wall angle 24mm x 24mm using 4mm thick High Pressure stean Crude Everest Non Asbestos Fiber Cement designer Board (E-Board Classic)in a grid of GI system duly suspended with 4mmdia GI bar hanger fixed with steel dash fasteners or iron purline from the roof with adjustment clip providing positions for light fixtures,air conditioning diffuser and ducts ,sprinkler ,smoke detectors etc.The main runners to be secured to structural soffits by hanger @ 1220 mm maximum c/c. the last hanger at the end of each main runner should not be placed at more than 450mm from the adjucent wall,Flush fitting 1220 mm cross tee to be interlocked between main runners @ 610mm c/c,so as to form 600mm x 600 mm grid all as specified and directed.Make:Everest Industries Ltd or equivalent as per IS 14862. |
| 115 | Supply and fix 110mm diaPVC (SWR) pipes single socketed, in any length, laid in trenches or in floors / fixed to walls complete all as specified. |
| 116 | Supply and fix 75mm diaPVC (SWR) pipes single socketed, in any length fixed to walls / floors or in trenches complete all as specified. |
| 117 | Supply and fix 110mm dia PVC (SWR) bend suitable for pipe complete all as specified. |
| 118 | Supply and fix 75mm bore PVC (SWR) bends any radius, fitted with oval access door complete all as specified. |
| 119 | Supply and fix 110mm bore PVC (SWR) junction, single T equal or unequal with or without door access complete all as specified. |
| 120 | M & LPVC(SWR) floor trap, 75mm dia outlet, plain with grating including jointing with solvent cement complete all as specified. |
| 121 | Supply & Fixed inrepairs PVC (SWR) bends 75 mm bore any radius suitable for pipe complete all as specified. |
| 122 | Supply & Fixed inrepairs 110 mm borePVC (SWR) junction single T, equal or unequal suitable for pipe complete all as specified. |
| 123 | Supply & Fixed inrepairsPVC (SWR) vent cowl110 mm suitable for pipe complete all as specified. |
| 124 | S&F 15mm bore steel water tubing, medium grade, galvanised with screwed and socketed joints, in any length, including supply and fixing all fittings, ISI marked conforming to IS -1239 and fixed to walls or laid in floors / trenches required for water connections complete all as specified and as directed. |
| 125 | S&F 20mm bore steel water tubing, medium grade, galvanised with screwed and socketed joints, in any length, including supply and fixing all fittings, ISI marked conforming to IS -1239 and fixed to walls or laid in floors / trenches required for water connections complete all as specified and as directed. |
| 126 | Refixing of 15mm dia old steel tubing and connections in new or old position (Walls, ceiling, floors, etc.) complete all as specified and as directed.Note: Old serviceable GI tube obtained vide item No 54 shall be reused. |
| 127 | Refixing of 20mm dia old steel tubing and connections in new or old position (Walls, ceiling, floors, etc.) complete all as specified and as directed.Note: Old serviceable GI tube obtained vide item No 55 shall be reused. |
| 128 | Cutting chases, pinning in, making good to facing where required and pointed in cement mortar 1:3 and making good cutting exceeding 10 cm girth complete all as specified. |
| 129 | Supply and fix as in repair 20 mm bore dia, Gun-metal, gate valves, with iron wheel head, screwed both ends on GI pipes with GI union fixed in existing/ new location including removing old unserviceable ones completeall as specified and directed. |
| 130 | S&F in reparis PVC ball valve 25mm dia high pressure of PTMT with aluminium rod &high density plastic ball screwed for iron pipe with including necessary tank lidall as specified |
| 131 | M & Lfor preparation of old decorated plastered or unplastered wall surfaces including brooming down or steel wire brushing , scrapping down smoke, soot , moulds , moss and efflorescent salts and trading oil and greasy spots etcand applying two coats of white wash complete all asspecified and directed. |
| 132 | M & Lfor preparation of old decorated plastered or unplastered ceiling surfaces including brooming down or steel wire brushing , scrapping down smoke, soot , moulds , moss and efflorescent salts and trading oil and greasy spots etcand applying two coats of white wash complete all asspecified and directed. |
| 133 | M & Lfor preparation of new or previously untreated ceiling surfaces and applying three coats of white wash complete all as specified and directed. |
| 134 | M & Lpreparation of new plastered surface of walls andapplying wall care putty of 1 mm thickness over prepare plastered surface with the surface even and smooth complete all as specified. |
| 135 | M & L preparation of new plastered surface of walls and applying two coat of oil emulsion distemper over one coat of primer with using roller complete all as specified. |
| 136 | M & Lfor complete removal of existing treatment on wall surface and applying two coat of oil bound distemper (white or tinted ) over a coat of primer complete all as specified and directed. |
| 137 | Material & Labour for preparation of new plastered surface applying two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm using roller complete all as specified and directed. |
| 138 | Material & Labour for Complete removal of existing treatment wall surface and applyin Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces complete all as specified. |
| 139 | M & Lpreparation of new steel surfaces of any description over 10cm width or girth not otherwise described and applying two coats of synthetic enamel paint over one coat of red oxide primer complete all as specified and as directed. |
| 140 | M & Lpreparation of new steel surfaces of any description n. exc 10 cm width or girth when unconnected with other painting or when painted in different tint with two coats of synthetic enamel paint over one coat of red oxide primer complete all as specified and as directed. |
| 141 | M & Lpreparation of old steel surfaces of any description over 10cm width or girth not otherwise described and applying two coats of synthetic enamel paint over one coat of red oxide primer complete all as specified and as directed. |
| 142 | M & Lfor preparation of new wooden surfaces of any description not other wise described over 10 cm width or girth and applying two coat of Synthetic enamel paint over a coat of pink primer complete all as specified and as directed. |
| 143 | M & Lfor preparation of new wooden surfaces of any description not other wise described n. exc 10 cm width or girth and applying two coat of Synthetic enamel paint over a coat of pink primer complete all as specified and as directed. |
| 144 | M & Lfor preparation of old wooden surfaces of any description not other wise described over 10 cm width or girth and applying two coat of Synthetic enamel paint complete all as specified and as directed. |
| 145 | M & Lfor preparation of old wooden surfaces of any description not other wise described n exc 10 cm width or girth and applying one coat of Synthetic enamel paint complete all as specified and as directed. |
| 146 | E & M Division items |
| 147 | Taking down carefully copper/aluminium point wiring (light, fan, buzzer, socket or power) complete including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc includingremoving from site for taking credit and making good to disturbed surface of walls, floors etc as per existing specification complete all as specified and as directed. |
| 148 | Taking down carefully submain wiring including all accessories without disturbing existing wiring fittings fixtures etc and making good to the disturbed surfaces all as directed and as specified in any type and size all as directed. |
| 149 | Taking out old U/s XLPE cable of any size/type taking out of olf bricks/cable cover complete all as specified and directed. (Excavation and earth work will be measured and paid separately under respective items) |
| 150 | Taking out old U/s GI PIPE of 25/32mm size/type including all GI fittings etc complete all as specified and directed. (Excavation and earth work will be measured and paid separately under respective items) |
| 151 | Dismantling of U/s GI pipe of size 40 mm bore complete all as specified and directed. |
| 152 | Dismantling old unserviceable main switches, sheet metal enclosures DB including MCBs etc and removing from site for taking credit incl making good to disturbed surface of wall as per existing specification complete all as specified and as directed. |
| 153 | M & L for point wiring with FRLSH stranded copper conductor 1.5 sqmm (nominal area), two single core, PVC insulated cable 1100 volts grade, ISI-694 markedin and including heavy duty, PVC casing caping including all accessories etc ISI marked, with PVC surface boxes suitable for fixing switches, sockets and regulators including PVC insulated stranded copper conductor 1.5 sqmm (nominal area) single core cable as earth continuity conductor to common earth and connecting to earth dolly complete all as specified and directed for One light point controlled by one switch. |
| 154 | M & L for point wiring with FRLSH stranded copper conductor 1.5 sqmm (nominal area), two single core, PVC insulated cable 1100 volts grade, ISI-694 markedin and including heavy duty, PVC casing caping including all accessories etc ISI marked, with PVC surface boxes suitable for fixing switches, sockets and regulators including PVC insulated stranded copper conductor 1.5 sqmm (nominal area) single core cable as earth continuity conductor to common earth and connecting to earth dolly complete all as specified and directed for One fan point/exhaust fan point controlled by one, one way switch 5 Amp. |
| 155 | M & L for point wiring with FRLSH stranded copper conductor 1.5 sqmm (nominal area), two single core, PVC insulated cable 1100 volts grade, ISI-694 markedin and including heavy duty, PVC casing caping including all accessories etc ISI marked, with PVC surface boxes suitable for fixing switches, sockets and regulators including PVC insulated stranded copper conductor 1.5 sqmm (nominal area) single core cable as earth continuity conductor to common earth and connecting to earth dolly complete all as specified and directed for One 3 pin 5 Amp socket outlet point controlled by one switch on the same board. |
| 156 | M & L for point wiring with FRLSH stranded copper conductor 1.5 sqmm (nominal area), two single core, PVC insulated cable 1100 volts grade, ISI-694 markedin and including heavy duty, PVC casing caping including all accessories etc ISI marked, with PVC surface boxes suitable for fixing switches, sockets and regulators including PVC insulated stranded copper conductor 1.5 sqmm (nominal area) single core cable as earth continuity conductor to common earth and connecting to earth dolly complete all as specified and directed forOne 3 pin 5 Amp socket outlet point controlled by one switch on independent board. |
| 157 | M & Lfor point wiring with FRLS stranded copper conductor2.5 sqmm (nominal area), two single core, PVC insulated cable 1100 volts grade, ISI-694 markedin and including heavy duty, PVC casing caping including all accessories etc ISI marked, with GI sunken box suitable for fixing switches, sockets and regulators including PVC insulated stranded copper conductor 2.5 sqmm (nominal area) single core cable as earth continuity conductor to common earth and connecting to earth dolly complete all as specified and directed for 3 pin, 15 Amp socket outlet, independent |
| 158 | M & Lfor point wiring with FRLSH stranded copper conductor4.0 sqmm (nominal area), two single core, PVC insulated cable 1100 volts grade, ISI-694 markedin and including heavy duty, PVC Casing caping including all accessories etc ISI marked, with GI sunken box suitable for fixing switches, sockets and regulators including PVC insulated stranded copper conductor 4.0 sqmm (nominal area) single core cable as earth continuity conductor to common earth and connecting to earth dolly complete all as specified and directed for one power point on independent board of AC/equipments etc controlled by one SP/SPN MCB. Note: The point wiring will be done from DBs to the switch sockets of any size with three wires running independently for each point and with no tappings. |
| 159 | M & Lfor point wiring with FRLSH stranded copper conductor1.5 sqmm (nominal area), two single core, PVC insulated cable 1100 volts grade, ISI-694 markedin and including heavy duty, PVC Conduit including all accessories etc ISI marked, with GI sunken box suitable for fixing switches, sockets and regulators including PVC insulated stranded copper conductor 1.5 sqmm (nominal area) single core cable as earth continuity conductor to common earth and connecting to earth dolly complete all as specified and directed for One light point controlled by one switch. |
| 160 | M & Lfor point wiring with FRLSH stranded copper conductor1.5 sqmm (nominal area), two single core, PVC insulated cable 1100 volts grade, ISI-694 markedin and including heavy duty, PVC Conduit including all accessories etc ISI marked, with GI sunken box suitable for fixing switches, sockets and regulators including PVC insulated stranded copper conductor 1.5 sqmm (nominal area) single core cable as earth continuity conductor to common earth and connecting to earth dolly complete all as specified and directed for One fan point/exhaust fan point controlled by one, one way switch 5 Amp. |
| 161 | M & Lfor point wiring with FRLSH stranded copper conductor1.5 sqmm (nominal area), two single core, PVC insulated cable 1100 volts grade, ISI-694 markedin and including heavy duty, PVC Conduit including all accessories etc ISI marked, with GI sunken box suitable for fixing switches, sockets and regulators including PVC insulated stranded copper conductor 1.5 sqmm (nominal area) single core cable as earth continuity conductor to common earth and connecting to earth dolly complete all as specified and directed for One 3 pin 5 Amp socket outlet point controlled by one switch on the same board. |
| 162 | M & Lfor point wiring with FRLSH stranded copper conductor1.5 sqmm (nominal area), two single core, PVC insulated cable 1100 volts grade, ISI-694 markedin and including heavy duty, PVC Conduit including all accessories etc ISI marked, with GI sunken box suitable for fixing switches, sockets and regulators including PVC insulated stranded copper conductor 1.5 sqmm (nominal area) single core cable as earth continuity conductor to common earth and connecting to earth dolly complete all as specified and directed forOne 3 pin 5 Amp socket outlet point controlled by one switch on independent board. |
| 163 | M & Lfor point wiring with FRLSH stranded copper conductor2.5 sqmm (nominal area), two single core, PVC insulated cable 1100 volts grade, ISI-694 markedin and including heavy duty, PVC Conduit including all accessories etc ISI marked, with GI sunken box suitable for fixing switches, sockets and regulators including PVC insulated stranded copper conductor 2.5 sqmm (nominal area) single core cable as earth continuity conductor to common earth and connecting to earth dolly complete all as specified and directed for 3 pin, 15 Amp socket outlet, independent |
| 164 | M & Lfor point wiring with FRLSH stranded copper conductor4.0 sqmm (nominal area), two single core, PVC insulated cable 1100 volts grade, ISI-694 markedin and including heavy duty, PVC Conduit including all accessories etc ISI marked, with GI sunken box suitable for fixing switches, sockets and regulators including PVC insulated stranded copper conductor 4.0 sqmm (nominal area) single core cable as earth continuity conductor to common earth and connecting to earth dolly complete all as specified and directed for one power point on independent board of AC/equipments etc controlled by one SP/SPN MCB. Note: The point wiring will be done from DBs to the switch sockets of any size with three wires running independently for each point and with no tappings. |
| 165 | S&Fswitch piano flush type button single pole one way 5 Amps all as specified and directed. |
| 166 | S&F socket outlet 2 in 1, 3 pin 5 Amp flush type all as specified and directed. |
| 167 | S&Fswitch piano flush type button single pole one way 15 Amps all as specified and directed. |
| 168 | S&F Socket outlet 2 in 1, 3 pin, 5 and 15amp flush type all as specified and directed. |
| 169 | S&F ceiling rose surface bakelite with three terminals all as specified and directed |
| 170 | S&F ceiling fan regulator socketed, step type, flush type heavy duty suitable to work on 230 volts Ac supply complete all as specified. |
| 171 | S&F lamp angular holder insulated body with back plate suitable for batten fittings all as specified and directed. |
| 172 | M & Lfor submain wiring with two single core 1.5 sqmm PVC insulated unsheathed cable multi-strand copper conductor FRLSH drawn through and including PVC non metallic rigid PVC Conduit with all fittings and fixing accessories on roof, walls, ceiling etc including 1 x 1.5 sqmm PVC insulated unsheathed multi strand copper conductor earth wire FRLSH connecting earth including cutting groove for concealed wiring, making good to disturb surface of wall/floor with cement mortar and finishes to match existing complete all as specified and directed.Note: Two run of single core cable, one run earth wire and one run PVC Conduit will be measured as one length. |
| 173 | M & Lfor submain wiring with two single core 4.0 sqmm PVC insulated unsheathed cable multi-strand copper conductor FRLSH drawn through and including PVC non metallic rigid PVC Conduit with all fittings and fixing accessories on roof, walls, ceiling etc including 1 x 2.5 sqmm PVC insulated unsheathed multi strand copper conductor earth wire FRLSH connecting earth including cutting groove for concealed wiring, making good to disturb surface of wall/floor with cement mortar and finishes to match existing complete all as specified and directed. Note: Two run of single core cable, one run earth wire and one run PVC Conduit will be measured as one length. |
| 174 | M & Lfor submain wiring with two single core 6.0 sqmm PVC insulated unsheathed cable multi-strand copper conductor FRLSH drawn through and including PVC non metallic rigid Conduit conceled with all fittings and fixing accessories on roof, walls, ceiling etc including 1 x 4.0 sqmm PVC insulated unsheathed multi strand copper conductor earth wire FRLSH connecting earth including cutting groove for concealed wiring, making good to disturb surface of wall/floor with cement mortar and finishes to match existing complete all as specified and directed. Note: Two run of single core cable, one run earth wire and one run PVC Conduit will be measured as one length. |
| 175 | Supply and fixing LED luminaire 600 mm x 600 mm, 35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete all as specified and directed. |
| 176 | Supply & Fix LED betten plastic type fitting of capacity 20W, operating on 230V, 50Hz, AC Supply having luminous efficacy of not less than 125 lumens/watts, CCT 6500K, P.F>0.9, 2.5 KV surge protection, 4-feet long, housing made out of extruded alluminium with decorative end caps elegently designed complete all as specified. |
| 177 | S&F wall mounted, compact LED batten 20 watt having 30 mins backup (working as regular 20 watt in normal mode and 4 watt in backup mode) and connecting with three core flexible copper conductor cable of suitable size from ceiling rose including taking down of old unserviceable one complete all as specified and directed |
| 178 | Supply and fixing LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed.. |
| 179 | S&F LED bulb 10 watt, 5 star rated and connecting to lamp holder complete all as specified and directed.Make - Crompton/Havells/M/S Jaquar & Company Pvt Ltd. |
| 180 | S&F BLDC ceiling fan 1200mm sweep complete with blades, down rods and accessories, 230 V, min air delivery 210 CFM with service value 6.00 BEE 5 star rated & provn of ‘S’ type fan hook includingincluding taking down of old UNSV one and depositing to MES storeyard for keeping in safe custody complete all as specified and directed. |
| 181 | S&F plastic body exhaust fan300 mm sweep complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, copper winding and connecting to ceiling rose with flexible copper cable including making holes on the wall and making good to the disturbed surfaces including taking down of old UNSV one and depositing to MES store yard complete all as specified and as directed. |
| 182 | S&F bldg security light, LEDluminaire 30 watt made up of pressure die cast alluminium body with mid power LED as lighting sources and PC cover having Top opening separate driver compartment with IP66 protection and impact resistance of IK07 including fixing arrangements and taking down old rusted bracket fittings completeall as per directed by Engr- in – charge. |
| 183 | S&F Angle bracket 40mm dia for fixing building security light of 40mm dia of 1 mtr long bent to shape 45 degree for fixing of security light including MS clamps of suitable size including nuts, bolts complete all as specified and directed |
| 184 | Supply and fix electric water heater, storage type steel body with copper inner tank and heating element upto 2 KW capacity 25 litre, BEE 5 Star rated complete with all accessories such as safety valve, thermostate, NRV, connection pipe etc complete all as specified and as directed. |
| 185 | S&F metal plug socket with MCB SP 20 Amp, 240 V enclosure for AC/equipment with neutral and earth point complete all as specified and directed. |
| 186 | S&F sheet metal enclosure powder coated single phase DB for fixing of MCBs, 8 way double door with bus bar includinggrouting on the wall by means of screws and rawal plugs and making good disturbed surfaces complete all as specified and directed. |
| 187 | S&F sheet metal enclosure powder coated three phase and neutral DB for fixing of MCBs, 4 way double door with bus bar includinggrouting on the wall by means of screws and rawal plugs and making good disturbed surfaces complete all as specified and directed. |
| 188 | S&F MCB TPN of capacity 63 Amps 4 pole,240 V, 10 KA \"B\" curve complete all as specified and directed. |
| 189 | S&F MCB SPN of capacity 40-63 Amps,240 V, 10 KA \"C\" curve complete all as specified and directed. |
| 190 | S&F MCB SP of capacity 5-32 Amps,240 V, 10 KA \"C\" curve complete all as specified and directed. |
| 191 | Taking out old existing earthing and M & Lfor new earthing with galvanised steel earth plate electrode 600mmX600mmX6mm thick burried directly in ground (earth pit not less than 2.25 mtr below ground level) with top edge of the plate not less than 1.5 mtr below ground level connected to 4mm dia GI wire protected by 20 mm bore light grade galvanised iron pipe and other end connected to test point as directed including funnel with wire mesh and watering pipe 20 mm bore medium grade galvanised iron pipe with charcoal and common salt in alternaterlayers of 15 cm thickness all around the GI plate electrode with concrete pit in PCC 1:3:6 type C-1 with cast iron frame including cast iron cover 10mm thick hinged to CI frame and 6mm MS rod for handle, necessary excavation and earth wok in hard/dense soil and disposal of spoil to a distance n exc 50 m and necessary testing complete all as shown in electrical plate No 3 of SSR part-I complete all as specified and directed. |
| 192 | Supply, fixing, commissioning & testing of XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, Electric power cable (heavy duty) with aluminium conductors, 1100 volts, grade cross sectional area 25 sqmm 3.5 core laid in trenches/fixed to wall/under road/pipe etc with copper cable glands & copper thimbles complete all as specified and directed. |
| 193 | Supply, fixing, commissioning & testing of XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, Electric power cable (heavy duty) with aluminium conductors, 1100 volts, grade cross sectional area 16 sqmm 4.0 core laid in trenches/fixed to wall/under road/pipe etc with copper cable glands & copper thimbles complete all as specified and directed. |
| 194 | Material & labour GI tube light grade 40 mm bore for protection ofcable complete all as specified and directed. |
| 195 | M & Lfor steel water tubing 25mm dia, medium grade galvanised with new fitting laid in trenches or on wall complete all as specified and directed. |
| 196 | S&F gun metal gate valve 25mm dia, cast copper alloy, screwed down high pressure with crutch or butterfly handle screwed both ends for iron pipe complete all as specified and directed. |
| 197 | M & L100mm thickPCC 1:3:6 type C2 using 40mm graded crushed stone aggregate for flooring complete all as specified and directed. |
| 198 | Excavation in trenches not exceeding 1.50 m wide and n.exc 1.5 m in depth for foundation of poles, cable etc, not exc 10 sqm on plan and getting out in soft/loose soil including taking out brick protection etc complete all as specified and directed. |
| 199 | Returning, filling in, including spreading, leveling, wateringand well ramming in layers not exc 25cm thick complete all as specified and directed. |
| 200 | Removing excavated materials (soils) not exc. 50m and depositing where directed at a level not exc. 1.5m above the starting point complete all as specified and directed. |
| 201 | M & L for sand cushioning by spreading in trenches crushed sand by gently by punning down manually as in cable protection all as specified and as directed by Engineer -in-charge. |
| 202 | Supply and laying un-reinforced precast concrete cable cover class LV, type-I, flat size 250 mm x 150 mm x 40 mm laid in trenches all as specified. |
| 203 | M & Lfor cutting of existing GI pipe line 25mm dia for inserting Tee and reducer etc for taking 25mm dia branch pipe including fittings complete |