Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | Surface dressingnot exc 15 cm deep and getting out in soft/loose soil all asspecified and directed by the Engr-in-Charge. |
| 2 | Excavating over areas, n exc 1.5 m deep and getting out soft /loose soil completeall asspecified and directed by the Engr-in-Charge. |
| 3 | Excavating over areas exc 1.5 m deep but n. exe 3 m and getting out soft /loose soil completeall asspecified and directed by the Engr-in-Charge. |
| 4 | M&L for anti-termite treatment by treating the backfill in contact with foundation at the rate of 7.5 liters of emulsion per square meter of vertical surface complete all as specified and directed by the Engr-in-Charge. |
| 5 | M&L for anti-termite treatment by treating the top surface of filled earth at the rate of 5 litres of emulsion per square meter of surface complete all as specified and directed by the engr-in-charge. |
| 6 | M&L for anti-termite treatment by treating the soil along with external perimeter of building at the rate of 2.25 litre of emulsion per metre of the perimeter wall complete all as specified and directed by the Engr-in-Charge. |
| 7 | M&L for anti-termite treatment by treating the soil under plinth protection at the rate of 5 liters of emulsion per square metre of surface area complete all as specified and directed by the Engr-in-Charge. |
| 8 | M&L PCC (1:4:8) type D2 using 40mm graded stone aggregate in foundation complete all as specified and directed. |
| 9 | M&L PCC (1:3:6) type C0 using 12.5mm graded stone aggregate in door frame filling complete all as specified and directed. |
| 10 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm in soft or loose soil complete all as specified and directed. |
| 11 | Removing excavated soil not exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point |
| 12 | Use and waste of formwork to sides of concrete foundations, footings, bases of columns, plinth beam and similar work rough finished surface complete all as directed. |
| 13 | Use and waste of formwork to sides of pillars, posts, columns etc in square, rectangular and similar work fair finished surface complete all as directed. |
| 14 | Use and Waste offormwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping) for fair finished surface complete all as specified and directed by Eng-in-Charge. |
| 15 | Use and waste of formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including sup- ports, overhangs, etc. also splays between floors and beams, etc for fair finished surface complete all as specified and directed by Eng-In-Charge |
| 16 | M & L RCC (design mix) M-25 ( 20mm graded stone agg) as in foundation, including rafts, plinth beams, footings all as specified and directed by Eng-In-Charge |
| 17 | M&L for RCC (design Mix) M-25 (20mm graded stone aggregate) as in Lintels, chajjas & roof beam all as specified and directed by Eng-In-Charge |
| 18 | M & L RCC (design mix) M-25 ( 20mm graded stone agg) as .columns, pillars, piers, posts and strutsall as specified and directed by Eng-In-Charge |
| 19 | M&L for RCC (design Mix) M-25 (20mm graded stone aggregate) as in slabsall as specified and directed by Eng-In-Charge |
| 20 | Supply and fix TMT bars 10mm dia and over, cut to length, bent to shape required,including binding with mild steel wire (annealed) not less than 0.9mm dia complete all asspecified and directed by Engineer-in-Charge. |
| 21 | Supply and fix TMT bars 6 to 8 mm dia, cut to length, bent to shape required,including binding with mild steel wire (annealed) not less than 0.9mm dia complete all asspecified and directed by Engineer-in-Charge. |
| 22 | M&L Brick work withsub class \"B\" Bricks burnt bricks, straight or curved on plan exceeding 6 mtr mean radius built in CM 1:6 all as specified and directed by Engineer - in - Charge . |
| 23 | M & L for rendering in two layer onfair faces of brick work or concrete surfaces of wall 5 mm thick in CM 1:4 mixed with WPCas per manufacturer\"s instructions of cement for finished even and smooth without using extra cement over 10 mm thick rendering incement mortar 1:6 complete all as specified and directed. Note - WPC shall be measured and paid separately as supply only. |
| 24 | M&L for 5mm thick rendering in CM 1:3 on brick work or concrete surfaces finished even and smooth w/o using extra cement in Ceiling etc complete all as specified and directed. |
| 25 | M & L for rendering 10mm thick on brick wall or concrete surface in cement mortar 1:6 finished even and smooth without using extra cement complete all as specified complete all as specified and directed by Eng-In-Charge |
| 26 | Supply Only Integral water proofing compound. |
| 27 | M&L for preparation of new plastered surfaces of walls andapplying two coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfacescomplete all as specified and directed by Engineer - in – Charge |
| 28 | M&L for preparation of surface and applying three coats of white wash all as specified on ceilings, etc complete all as specified and directed by engr-in-charge. |
| 29 | M&L for two coats Of Oil Bound Distemper over one coat of wall primer over avg 2mm thick wall care putty all as specified with approved color pattern on walls, beams, soffits, columns, etc. complete all as specified complete all as specified and directed by Eng-In-Charge |
| 30 | S & F for mild steel framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete |
| 31 | S&F for 35mm thick factory made Flush shutters, solid core construction, with block board core and plywood face panels, commercial type 1.0mm thick (veneered on both side) with decorative choice laminated type 1 (factory laminated), or surface finish, 6mm thick or external teak wood lipping fixed with nails, color and pattern as approved by EIC/GE. |
| 32 | S & F 35mm thick 2nd class Hard wood Glazed and Skelton shutters, open rebated and prepared to receive glass, gauze etc (without sash bars) edges of framing plain, chamfered or rounded, fitted with cut ,mitered andmoulded beads for securing glass etc, sizes of members of shutters as specified in SSR Part-I, Section 8, clause 8.20(a) and fitted to chowkats. |
| 33 | S & F solidPVC door frame of size 50mmx47mm made out of 5mm pre-lam PVC sheet reinforced with MS square tube, supplying and fixing in opening as per specification and drawing and matching with door shutter shade.The door frame shall be tied to the wall using 75/100mm long MS screw as directed. |
| 34 | S & F 30mm thick factory made both sides prelam panel PVC door shutter consisting of frame made out of MS tube of 19 gauges thickness and size 19mm x 19mm for stiles, top and bottom rails, MS frame shall have a coat of steel primer of approved make and manufacture. MS frame shall be covered with 5mm thick heat moulded prelam PVC C channel size 30mm thickness, 70mm width, out of which 50mm should be flat and 20mm shall be tappered in 45 degree < on either sides forming stiles and 5mm, 95mm wide prelam PVC sheet out of which 75mm shall be flat and 20mm shall be tapered in 45 degree on the inner side to form top and bottom rail and 115mm wide. prelam PVC sheet out of which 75mm shall be flat and 20mm shall be tappered on both sides to form lock rail. Top rail, bottom rail and lock rail shall be provided either sides of the panel 10mm (5mm x2) thick 20mm wide cross PVC sheet shall be provided as gap insert for top rail, and bottom rail paneling of 5mm thick both side prelam PVC sheetto be fitted in the MS frame welded/ sealed to the stiles and rails with 7mm (5mm+2mm) thick 15mm wide. PVC sheet beading on inner side and jointed together with solvant cement adhesive, an additional 5mm thick PVC strip of 20mm width is to be stuck on the interior side of C channel using PVC solvant adhesive etc. complete all as specified and directed. |
| 35 | S&F stainless steel Hinges of size25*25*100* 3mm thick complete all as specified and directed. |
| 36 | S & F aluminium alloy, anodized sliding door bolt with hasp and staple (bolt type) and fixing clips of sheet cast or extruded sections and fixing bolt and sliding bolt of extruded section length of bolt of 300mm long. |
| 37 | S & F aluminium anodized barrel tower bolt of extruded section and fixed of size 150mm complete all as specified and directed by Eng-In-Charge/JE. |
| 38 | S&F extruded aluminium alloys handles fabricated type anodized of size 150mm long complete all as specified and directed by Eng-In-Charge/JE. |
| 39 | S&F curtain rails 25mm dia ofmild steel, chromium plated with fixing brackets, stops, rollers etc. complete all as specified and directed. |
| 40 | S&F powder coated aluminium (minimum thickness of powder coating not less than 50 micron) work for frame and shutters of doors, windows, ventilators and partitions (fixed portions) with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required epdm rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, aluminium snap beading for glazing/ paneling, C.P. brass/ stainless steel screws, all complete as per drawings and as approved and directed by Engineer-in-charge. |
| 41 | S&F 4.00mm thick sheet glass, selected quality and glazing with rubber beading or with glazing clips, all as specified and directed. |
| 42 | S&F mild steel framed work such as grills, gratings, etc. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.gde-E-165 complete all as specified and directed. |
| 43 | S&F stainless steel wire cloth. 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples |
| 44 | M & L for 16 to 18 mm thick machine cut green marble stone as in floor, steps (in single piece), cooking platform, cills of window etc laid over 15 mm thick cement screed and jointed withbase laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete including15mm thick plaster incement mortar 1 : 4 complete all as specified and as directed. |
| 45 | M&L Machine cut kota stone slab flooring 20-25mm thick over cement screed 15mm thick in CM 1:6 base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and mirror polishing complete. |
| 46 | M&L Machine cut kota stone slab 15-18mm thick as in verticle surface including 10mm thick backing coat in CM 1:4and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and mirror polishing complete. |
| 47 | M&L fornon - skid Ceramic coloured tiles 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade including screed bed or bedding layer of mortar 15 mm thick for laying floor finishes withCM 1:6 as approved by the Engr-in-Charge/GE all specified and directed. |
| 48 | M&L for PCC 25mm thick 1:2:4 Type B0 (12.5 mm graded stone aggregate) as in sub base complete all as specified and directed. |
| 49 | M&L for PCC 75mm thick 1:4:8 Type D2 (40mm graded stone aggregate) as in sub base complete all as specified and directed. |
| 50 | M & L for Glazed ceramic coloured walls tilesin vertical surfaces 300x450x 6mm to 7 mm thick set over and including high performence adhisive, tile adhisive or equivalentmixed in cement as per manufacturer instructionand jointed with polymer modified cementetious groutof pigment matching to tile color including 10mm thick rendering for screed bed on vertical surface of wall or concrete surfacesin CM 1:3 to receive wall tiles (Tile pattern and decoration may be as suggested by Engineer-in-charge). |
| 51 | M & L PCC 75mm thick as in Plinth protection (1:3:6) using 20mm graded stone aggregate surface even and smooth without using extra cement . |
| 52 | M&L for hardcore of gauge n exc. 63 mm, of broken stone deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface |
| 53 | M&L for rendering 10mm thick cement mortar 1:3 on concrete surface even and smooth with waterproofing compound on roof surface as directed by Engr-in-Charge |
| 54 | M&L for water Proofing treatment to roof slabs by applying one coat of bituminious/polymerized primer confirming to IS-3384 @ 0.40 Ltrs/Sqm, 3 mm thick APP modified polymeric membrane of weight of 3 kg/sqm with non-woven polyester reinforcement shall be laid over a coat of bitumen S-35 grade (30/40) applied @1.20Kg /Sqm (minimum) with minimum75 mm side overlaps and minimum 100 mm end overlaps, joints & overlaps shall be sealed and applying one coat of aluminium paint @ 0.11 Kg/Sqm over APP membrane complete all as specified and directed by Engr-In-Charge (Note: the primer and the membrane to be used shall be of the same manufacturer and to be applied by authorized applicator of OEM). |
| 55 | S&F Vitreous China Squatting pan,\"Orissa\" pattern size 580x400 whitewith intergral foot rest complete including provision of lime concrete bedding (excluding flushing cistern and flush pipe). |
| 56 | S&F PVC flush pipe of 32 mm dia upto 750mm long, complete all as specified and directed. |
| 57 | S&F Toilet Paper Holder, mild steel chromium plated as per standard size complete all as specified and directed. |
| 58 | S&F Vitreous China Urinal Bowl Type 465x355x265mm \"white\" with suitable size of CP grating fixed with wallcomplete all as specified and directed. |
| 59 | S&F C I Nahani Traps 75mm Bore complete all as specified and directed. |
| 60 | S&F C I Floor Traps 75mm Bore complete all as specified and directed. |
| 61 | S&F WHB Vitreous China White Size 550x400 fixing with wall with suitable brackets with including brass CP coupling complete all as specified and directed. |
| 62 | S&F 600mmx450mm bevelled edge mirror of selected quality glass, mounted on 6mm thick AC building board or commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers |
| 63 | S & F 110mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors all as specified and as directed |
| 64 | S & F 75mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors all as specified and as directed |
| 65 | S&F PVC Bend Suitable For 110 mm bore pipe complete all as specified and directed. |
| 66 | S&F PVC Bend Suitable For 75 mm bore pipe complete all as specified and directed. |
| 67 | S & F rotational moulded PVC water storage tank 1000ltrs capacity conforming to IS-12701(1989) cylindrical vertical type three-layered white coloured with closed top including inlet,outlet and wash out holes of approved make hoisted and fixed in position all as specified in SSR Part I including S&F 20mm ball valve high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball screwed for iron pipe and fixed (minimum weight 455 gms) including 20mm dia GI pipe for over flow complete all as specified and directed. |
| 68 | S&F Stop valves of 15 mm dia cast copper alloy chromium plated long shank, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for unions and fixed |
| 69 | S&Fbrass chromium plated basin mixer for mixing hot and cold water screwed down for iron pipes and fixed, complete all as specified and as directed by engineer in charge. |
| 70 | Supply and Fixing PVC connections 15mm size with PTMT nuts of length 450mm etc all as directed and specified. |
| 71 | S&F PVC valveless symphonic action type flushing cistern, low level white with inlet ball valve float and handle including brackets, flush pipe. 10 ltr capacity complete all as specified and as directed by engineer in charge. |
| 72 | S&F 15 mm Fancy type Bib taps long body cast copper alloy chromium plated with crutch handle, screwed down complete all as specified and as directed by engineer in charge. |
| 73 | S&F 15 mm Bib taps, cast copper alloy chromium plated with crutch handle, screwed down, screwed for iron pipe complete all as specified and as directed. |
| 74 | S&F Tube \"medium grade\" galvanized, with all fitting and fixed complete to walls and ceiling etc 25mm bore complete all as specified and as directed by engineer in charge.. |
| 75 | S&F Tube \"medium grade\" galavanised, with all fitting and fixed complete to walls and ceiling etc 20mm bore complete all as specified and as directed by engineer in charge.. |
| 76 | S&F CPVC Pipes & fittings of 20mm outer dia on walls/ceiling or laying in floors complete all as specified anddirected by engineer in charge. |
| 77 | S&F gun metal gate valve 25mm globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and as directed. |
| 78 | S&F gun metal gate valve 20mm globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and as directed. |
| 79 | S&F brass chromium tubular towel rail, 20mm dia, D type, 60cm long complete all as specified and as directed. |
| 80 | S&F Sheet glass shelf assembly consisting of 5.5mm thick sheet glass shelf 12cm wide with chromium plated bracket guard and railing 60cm long complete all as specified and as directed. |
| 81 | S&F Soap dish, mild steel chromium plated, approximate size 160x 160x90mm fixed with chromium plated screws complete all as specified and as directed. |
| 82 | S &F 125 mm ,chromium plated ,shower rose with swivel joints including fixing to unions. |
| 83 | Surface excavation not exceeding30 Cm deep and averaging15 cm deep and getting out in soft / loose soil. |
| 84 | Excavating in post holes (or similar holes) each n exc 0.5 cum in soft/loose soil, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25cm, watering, and removing surplus soil to a distance n exc 50 m and making good surface |
| 85 | M & L for providing PCC1:3:6 type C2 using 40 mm graded stone aggreagate as in posts. |
| 86 | M&L for steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to IS 1161-1979 grade St.-240 |
| 87 | M&L for Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified |
| 88 | Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified |
| 89 | M&L two coat synthetic enamel paint over a coat of red oxide primer on steel surfaces of any description over 10cm in width or girth not otherwise described including preparation of surfaces. |
| 90 | Removing excavation material exc 250m but n.exc 500 m and depositing where directred. |
| 91 | Machine pressed, precast plain cement concrete Interlocking paver block, factoty made( with grey cement and no pigment) conforming to IS-15658-2006, 60 mm thickness laid over and including 25 mm average thick sand cushioning layer & joints filled with sand in hardstanding etc, fabricated withM-35 grade concrete, complete all as specified and directed. |
| 92 | Excavting in trenches, n exc 1.5 m wide and n exc 1.5m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes and for pipe/cable/poles/stay/strut etc. n exc 10 sqm on plan and n exc 1.5 m in depth and getting out soft/loose soil complete all as specified and directed. |
| 93 | M&L for cement concrete bed to drain pipes in PCC 1:4:8, type D2 (using 40mm graded stone aggregate), for 150mm dia drain pipe including packing under and haunching against the sides of pipes with concrete after they are laid and tested complete all as specified and directed. |
| 94 | M&L for reinforced concrete pipe of 150mm bore of pipe, class NP-2, laid and jointed in cement mortar (1:1) complete with collars complete all as specified and directed. |
| 95 | M & L brick work with sub class \"B\" bricks of old size, straight or curved on plan exc 6m mean radius built in CM (1:4) complete all as specified and directed. |
| 96 | M&L for PCC (1:2:4) type B-1 using 20 mm graded aggregate as in benching to surface channels for manholes or drains etc, including finishing top of benching even and smooth using extra cement and including necessary formwork,complete all as specified and directed. |
| 97 | M&L for extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using extra cement including forms, moulds, mitred / stopped ends etc complete all as specified and directed. |
| 98 | M&L, rendering 10 mm than fair faces of brick work or concrete suraces in CM 1:4 finished even and smooth without using extra cementcomplete all as specified and directed. |
| 99 | M&L for pre-cast reinforced cement concrete1:2:4, type B1 (using 20mm graded stone aggregate) as in manhole coverwith plain fair surface including chamfers, weatherings, throatings, necessary form work and set in CM (1:6), placed in position complete all as specified and directed. |
| 100 | M&L for PCC 1:2:4, Type B-0 using 12.50mm graded stone aggregate as in coping, including necessary formwork, weathering, slightly rounded or chamfered angles and throating complete all as specified and directed. |
| 101 | M&L for on site LLDPE septic tank designed to carry sewage and sullage water, With Upflow filter including media , excavation in any type of soil, PCC 1:4:8 below foundation, Vent shaft, Lied, connection etc., complete for 05 number user. |
| 102 | Provision of Soakage wells by excavation in ordinary soil, foundation in PCC 1:3:6, wells of Honey Combed and soild in M-25 concrete, including interepting chamber, screen, chamber brick work in CM, RCC cover slab in M-25/RR masonary/Filling with brick bats, complete of size 1.8M dia X3.0M deep complete all as per TD drg & as directed. |
| 103 | M&L for concealed point wiring with 1.5 Sqmm PVC-FRLS insulated, sheathed, copper conductor, stranded 1100 volt grade cable in & incl PVC conduit,includingmodular metal flush boxes & modular white cover plate with frame as per site requirement all fittings such as tees, bends, elbows,etc. of External diameter 20mmall as per site requirements PVC insulated & sheathed 1100 volt grade copper conductor, stranded 1.5 sqmm. cable as continuous earth lead complete all as specified and directed by Engr-in-charge for the followings:- |
| 104 | One light, fanpoint controlled by one switch |
| 105 | One 3 pin ,5 Amp socket point with other switch on the same board |
| 106 | All as per item No 103 here in before but for power point wiring usingwith 2.5 sqmm PVC FRLS insulated ,unsheathed, copper conductor stranded 1100 volt grade copper conductor, stranded 2.5 sqmm. cable as continuous earth lead complete all as specified and colour coding of cables such as Phase -Red, Neutral – Black, and Earth – Green. |
| 107 | S&F Modular switch, one way, 6 Amp 230, 1 module. |
| 108 | S&F socket Modular 6 Amp-2/3 pin combined 2 module. |
| 109 | S&F modular socket 6 A/16-2/3 pin combined 2 module . |
| 110 | S&F ceiling rose, surface backlit,three terminal. |
| 111 | S&F modular fan step regulator 120W, 2 module. |
| 112 | S&F, testing and commissioning of MCB SP 5 Amp to 32 Amp 240 Volt 10 KA capacity having C-curve characteristics connected with suitable lugs. |
| 113 | S&F double door metallic sheet metal enclosure for MCB DBdouble doorSPN 8 Way 415 Volts with 200 Amps rated bus bars.Note :- Cutting and chasing in stone masonary and making good to disturbed surfaces will be including in item rate . |
| 114 | S&F, testing and commissioning MCB SPN 40 Amps415 Vincluding making electrical coming/outgoing connections with lugs/thimbles all as specified & directed. |
| 115 | Supply and fixing LED lights fitting 1x 20W, 220V,AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete. |
| 116 | Supply and fixing LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete. |
| 117 | Supply and fix ceiling fans, complete with three blade, down rod, accessories 230V, 1200mm sweep, \"White\" with Squirrel cage induction motor. |
| 118 | M&L for provn of Earthing complete with galvanised steel earth plateelectrode, 600x600x6mm buried directly in ground (Earth pit not less than 2.25M deep below the GL) with top edge not less than 1.5 metres below ground level connected with galvanized earth lead wire 4 mm dia by means of bolts, nuts, check nuts & washers of GI or steelall as shown in electric plate no 3 connected to earthing test point all as specified or indicated including testing on completion.Note :- (i) The rate quoted shall also deemed to include the cost of GI wire and protection pipe upto 7.5 Mtr beyond the earth plates electrode and also the costof the Test point. (ii) Joining of GI earth wire with pipe of the test point shall be done by using suitable cable lugs. |
| 119 | Supply and fix desert cooler electric driven (single phase), having nominal air flow capacity of 4000 CuM per hour (or nearest size) Plastic/PVC Body complete & as directed. |
| 120 | Drilling the borewell of size 12\" incl UPVC casing pipe 200 mm (6\"),Min 6.5 mm thick (Duke ISI - CS threaded 3 meters length) and pea Gravell packing around the casing pipe with in all kind of soil & strata including disposal of surplus soil with in 100 mtr well ramming & stablizing of material and transporotation of drilling rig and other T&P to the site and back complete all as specified and directed by Engr-in-Charge. Note(a) The rate quoted by the tenderers shall deemed to include suitable truck mounted drilling incl transportation alongwith necessary T & P required at site for digging of borewell. |
| 121 | Supply, Install, lowering, testing, and commissioning of Submersible pump 70 Mtr head set multi stage with electric driven motor of minimum capacity 2 HP, 3 phase, 415 Volts, 50Hz,AC completeall as specified anddirected by Engineer-in-Charge. |
| 122 | Supplying and fixingwater proof flat submersible copper conductor cable 2.5 sqmm (Green & White ISI marked), 3 core,1100 volts grade including nylon binding wire and accessories to clamp with column pipe at places to column pipe complete all as specified and directed Engineer-in-Charge. |
| 123 | Supply, install, test and commissioning of Submersible starter suitable for 2 HP motor all as specified and directed by Engr-in-Charge |
| 124 | S & F for HDPE pipes of size 1.25\",20 kg/cm square including all necessary accesseries complete all as specified and directed |
| 125 | S & F of stainless steel wire rope size of 6 mm dia complete set all as specified and directed |
| 126 | S& F of SS step nipple 1.25\" complete all as specified and directed |
| 127 | S & F of GI elbow and nipple of size 1.25\" complete set all as specified and directed |
| 128 | S & F ofSS clamp for wire rope complete set all as specified and directed |
| 129 | S&F of material carting complete all as specified and directed. |
| 130 | S & F of PVC bore cap of suitable size as per site requirement complete all as specified and directed |
| 131 | S & F of MS clamp of size 1.25\" complete all as specified directed |
| 132 | Development of bore well as per IS-2800 using min 250 PSI air compressor till silt free clear water is obtained from the well for an uninterrupted period.The final discharge shall be free from sand complete to deliver 3 LPS of water complete all as specified and directed by Engineer-in-Charge. |
| 133 | Testing and commissioning of Electro logging survey of complete borewell and test report submited to Engr-in-Charge complete all as specified and directed |
| 134 | Supply and laying of G I tubingmedium gradeof 50 mm borewith all fittings and fixtures fixed to wall and ceiling or laid infloor/trenches complete all as specified and directed. |
| 135 | S&FtheGun metal Gate valve iron wheel head both end screwed of size 50 mm bore for iron pipe approved all as specified and directed. |
| 136 | Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 16 sq mm 4 core |
| 137 | Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 10 sq mm 2 core |
| 138 | Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 25 sq mm 4 core |
| 139 | Supply & fixing of Steel tubular swaged Pole complete with cast iron base plate,final taper plug,bolts,nuts & screws as specified type 410 SP-31 9.0 Mtr long including two coat of aluminium painting complete. |
| 140 | Supply and fixstreet light box of PVC consisting of 01 No MCB SP 6 Amps \"C\" series, 10 KA capacity single phase including aluminium strip bus bar for incoming and outgoing cable with necessary connection duly fixed on the pole with suitable size of MS clamp as approved and directed.(make sintex of as per list of make) |
| 141 | Supply & Fix70 Watt LED Street Light fitting New generation energy saving and environmental friendly long life LED street light made up of pressure die cast aluminium housing with high power LED as lighting source and lens embedded PC cover having TOP OPENING seperate driver compartment with IP66 protection and impact resistance of IK07 with 10KV Built-in Surge Protection Device,lumens should be ≥120 lm/w ,OEM driver,PF 0.9,CCT 5700K.Make:- Cat par no Bajaj ENXT P 84L WH PO PC SD MT , INDURASUNBEAMGENXSL70WLED757SASYBOPC Of Havells or LST-70-CDL-M of crompton .Note :- The warranty on light should be minnimum of 2 Years . |
| 142 | M&L for three core copper conductor cable of size 1.5 sqmm for junction box to street light fitting complete |
| 143 | Supply, install, test and commissioning of factory made cubical outdoor LT feeder piller box confirming to IP-54 complete weather proof and verminproof and the shell shall be of 3.15mm thick MS Sheet with particians and switch enclosure doors of 1.6mmand canopy made out of 3.15mm thick MS sheet all as per IS shall be available inside for easy access and working condition.It should be mounted on 40 x40 x 6mm angle frame duly painted with two coats of enameled paint on a coat of red oxide primer with a clearance of at least 0.45mtrs above GL.Markings should be made to identify incoming and outgoing circuits. Outdoor feeder pillar box comprising of following :-a) MCCB,4pole, 100 Amps, 16KA(As Incomer)-01 No (b) MCCB, 4 pole, 63 Amps, 16KA (Outgoing) -03nosc) Digital Ammeter of range 0 - 400 Amps with suitable capacity C.T. and selector switch - 01 Setd) Digital Voltmeter of range 0-500 Volts with selector switch - 01 Sete) AluminimumBus bar 1 phase 2 wire of capacity 100 Amps - 01 Setf) LED phase indicating lamp - 1 Set. g)MCB SPN 40 amp \"C\" series-02 Nos(outgoing) |
| 144 | M&L for earthing complete with galvanised steel earthplate electrode 600X600X6 mm thick, burried directly in ground,earth pit not less than 2.25 meter deep below ground level with top edge of earth plate not less than 1.5 meter below ground level, steel earth plate connected with 32 x 6 mm GI strip by means of bolts, nuts, check nuts and washer of galvanised iron or steel as shown in electrical plate No. 3 connected to earth test point all as described in MES schedule part II including excavation earth work concreate pit with 50 mm thick RCC cover in RCC 1:2:4 type B-I duly reinforced with MS bars 6 mm dia @ 150 C/C both ways and pit chamber in PCC 1:2:4 type B-I with 2 Nos suitable lifting handles of 12 mm MS bar and GI protection pipe of suitable size,and watering pipe 20 mm dia with water funnel test point and extra length up to 7.5 meter connected to Panelboard all as specified |
| 145 | M & L for sand cushioning to PVC cable with using clean dry and natural river sand gently punning below/around cable all as specified. Note:- Only punned thickness shall be measured for payment. |
| 146 | M & L well burnt bricks sub class \"B\" as in protection of cable laid dry, flat abutting each other width wise all as directed |
| 147 | M&L for cement concrete 1:3:6 Type -C1 (using 20 mm graded stone aggregated) as in coping of poles including all necessary formwork complete |
| 148 | M&L for cement concrete 1 : 3 : 6 Type - C2(using 40 mm graded stone aggregated) foundation of poles, Stays etc including all necessary formwork complete all as specified as directed. |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy