| 1 | Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable and 1.5 sq.mm FRLS PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel/PVC conduit including dismantling as required. |
| 2 | Group C |
| 3 | Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. |
| 4 | 3 x 1.5 sq. mm |
| 5 | 3 x 2.5 sq. mm |
| 6 | 3 x 4 sq. mm |
| 7 | Supplying and fixing of following sizes of steel conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required. |
| 8 | 25 mm |
| 9 | Supply and fixing of 32 x 20 mm DLP mini- trunkingwhite-system with independent coveretc. as required complete. |
| 10 | Supply and fixing of following accessories suitable for 32 mm x 20 mm sizeplastic trunking white system. |
| 11 | End cap |
| 12 | internal / external angle |
| 13 | changeable flat angle |
| 14 | flat junction |
| 15 | Supply and fixing of 105 x 50 mm DLPtrunkingwhite-system but without cover and partition etc. as required complete. |
| 16 | Supply and fixing of following accessories suitable for 105 mm x 50 mm sizeplastic trunking white system. |
| 17 | 85 mm flexible cover |
| 18 | End cap |
| 19 | Internal angles- adjustable from 80°-100° |
| 20 | external angles- adjustable from 60°-120° |
| 21 | flat junction |
| 22 | flat angles |
| 23 | separation partitions |
| 24 | Joints for 85mm width cover |
| 25 | base joints |
| 26 | Supplying and fixing following modular switch/ socket on the existing clip-on frame fixed on 85mm cover of 105 x 50 mm DLP plastic trunking including connections etc. as required complete. |
| 27 | 6 A switch |
| 28 | 20 A switch |
| 29 | 6 A pin 2/3 pin socket outlet |
| 30 | 6/16 A 3 pin socket outlet |
| 31 | Supplying, installation of Clip-on frame with finishing plate for 85mm cover for DLP plastic trunking 105mm x 50mmetc. as reqd. |
| 32 | 3 module |
| 33 | 6 module |
| 34 | S & F following size of steel flexible pipe along with the accessories on surface etc as required |
| 35 | 25 mm |
| 36 | 32 mm |
| 37 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. |
| 38 | 5/6 A switch |
| 39 | 15/16 A switch |
| 40 | 3 pin 5/6 A socket outlet |
| 41 | 6 pin 15/16 A socket outlet |
| 42 | Blanking Plate |
| 43 | Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required. |
| 44 | 3 Module |
| 45 | 6 Module |
| 46 | Supplying and fixing following size/ modules, plastic boxfor modular switches in recess etc as required. |
| 47 | 3 Module |
| 48 | 6 Module |
| 49 | Supplying and fixing following piano type switch/ socket on the existing switch box/ cover including connections etc. as required. |
| 50 | 5/6 amps switch |
| 51 | 15/16 A switch |
| 52 | 3 pin 5/6 A socket outlet |
| 53 | 6 pin 15/16 A socket outlet |
| 54 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/lsolator) |
| 55 | 6 way, Double door |
| 56 | Supplying and fixing following rating, 240/415 V, 10 kA, \"C\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 57 | Single pole 5 A to 32 A |
| 58 | Double Pole (40A-63A) |
| 59 | Supplying and laying of one no. 4 x 16.0 sqmm PVC insulated, XLPE steel armoured aluminium conductor power cable of grade 1.1 kVas required complete in following manners. |
| 60 | in open duct |
| 61 | On Surface |
| 62 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. |
| 63 | 4 X 16 sq. mm (28mm) |
| 64 | Fabricating, supplying & fixing of box of required size and shapemade out of 2mm thick CRCA sheet duly powder coated, Locable & openable from or front, top or bottomas required complete. |
| 65 | Supplying & fixing3mm (1/8\") thick phenolic laminated sheet on existing board with screw & washer etc. as required. |
| 66 | Laying of 1/2/3 run ofUTP cable enhanced cat 5/cat 6 cable in existing steel conduit pipe/GI pipe/ raceway / RCC pipe as reqd. the cost shall also include numbering of networking wire from room to rack as reqd. (wire will be supplied by dept) |
| 67 | Fixing of RJ-45 modular box with cover plate or I/o box for interneton surface/ recessed cutting the wall making good the same as required. ( box and cover plate will be supplied by dept.) |
| 68 | Dismantling, disconnecting old damaged unserviceable fl fitting/ exhaust fan/ ceiling fan/ bulkhead fitting with bracket etc. as reqd. and depositing in sectional store. |
| 69 | Chemical Earthing with GI earth electrode 50 mm dia x 3 Mtr length with full GI strip including earth enhancing compound and RCC precast PIT cover and earthing pit etc as reqd. |
| 70 | Providing and fixing 25 mm X 5 mm G.l. strip on surface or in recess for connections etc. as required. |