| 1 | Surface preparation to receive micro concrete by chipping to depth to max 75mm, cleaning removing the traces of dust, loose concrete etc. includind the cost of the labour charges, minor tools, etc complete. |
| 2 | Supplying preparing and priming the reinforcement steel with epoxy zinc. Primer or epoxy anti- corosive paint (Conforming to having IS/BIS Certification) including the cost of all materials labour minor tools, etc. |
| 3 | Supply and application of epxy concrete bonding, agent (conforming to and having BIS 6319 certification)and over cleaned and properly prepared old concrete surface to give good bonding between old and new concrete, including cost of all materials, minor tools etc. complete. |
| 4 | Supplying, mixing and applying curing membrane or equivalent with water including cost of all materials all labour charges, minor tools etc. complete. |
| 5 | Supplying and applying high strength non shrink cementinous free flow concrete ( eith minimum 28 days flexural strength 50kg/sq.cm and compressive strength 500 kg/sq.cm as per BIS 4551-80) for above water level on site to enable completion of pouring in a continous operation. An approved grout concrete mixture of slow speed heavy duty drill and exact quantity of water as recommended should be poured into the vessel slowly and mix the same throughly in a forced action. The mix materials should be placed immediately to position foam work continously to an average thockness of 50mm without any gap including all materials and labour charges etc. complete. |
| 6 | Removing dry or oil bound distemper, water proofing cement paint and the like by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete. |
| 7 | Finishing walls with Acrylic Smooth exterior paint of required shade : |
| 8 | Old work (Two or more coat applied @ 1.67 ltr/ 10 sqm) on existing cement paint surface |
| 9 | Distempering with 1st quality acrylic distember (Ready mix) having VOC content less than 50 grams/ litreof approved brand and manufacture to give an even shade : |
| 10 | Old work (one or more coats) |
| 11 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade: |
| 12 | One or more coats on old work. |
| 13 | Providing and fixing in position eave or facia board with 12 mm thick non asbestos plain sheet of HILUX Board and 30 cm wide including nailing etc. Complete as per the direction of Engineer-in-charge. |
| 14 | Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. |
| 15 | Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge. |
| 16 | Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix) |
| 17 | Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 Pulverised sand : 6 graded stone aggregate 20 mm nominal size) over 75mm thick stone aggregate 40mm nominal size well rammed and consolidated and grouted with Pulverised sand includingfinishing the top smooth. |
| 18 | Cement concrete flooring 1:2:4 (1 cement : 2 pulverised sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete. |
| 19 | 40 mm thick with 20 mm nominal size stone aggregate |
| 20 | Providing cement concrete surface drain with CC 1:3:6 (1:Cement, 3: Sand, 6: Graded Stone Aggregate 40 mm nominal size), including earthwork in excavation, 10cm thick bed concrete and 15cm thick side walling, finishing with 12mm thich cement plaster 1:4 and a floating coat of neat cement on top sides and insides and inside and disposal of surplus earth etc complete. |
| 21 | 15 x 15cm Surface drain. |
| 22 | Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approved steel primer. |
| 23 | G.I. pipes |
| 24 | ELECTRICAL WORKS |
| 25 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC Conduit, with piano type switch, suitable size PVC box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required. |
| 26 | Group C |
| 27 | Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC Conduit, with 2 way piano type switch, suitable size PVC box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required. |
| 28 | Dismantling of various wiring for light point/exhaust fan point/call bell point/batten anle holder piont with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface/recessed medium class PVC conduit, wiht piano type switch, suitable size PVC box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. |
| 29 | Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC Conduit, alongwith 1 No 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. |
| 30 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC Conduit as required |
| 31 | 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire |
| 32 | 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire |
| 33 | 2 X 6 sq. mm + 1 X 6 sq. mm earth wire |
| 34 | Supplying and fixingSuitable PVC boxon surface or in recess, including providing and fixing 3 pin 5/6 amps socket outlet and 5/6 amps piano type switch, connection, painting etc. as required.Make anchor/Polycab/Havells. |
| 35 | Supplying and fixing Suitable PVC box on surface or in recess, including providing and fixing 6 pin5/6 & 15/16amps socket outlet and 15/16 amps piano type switch, connection, painting etc. as required.Make anchor/Polycab/Havells. |
| 36 | Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required |
| 37 | Supplying of prewired LED tube light 20W LUMEN output 2000lm 6500K Product code PANASONIC PBTM02203 or equivalent to ISI standard.(Havells/Panasonic/Polycab) or Equivalent to ISI Standarad. |
| 38 | Installation, testing and commissioning of pre-wired, LED FITINGof all types, complete with all accessories and tube etc. directly on ceiling/ wall, including connection with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required. |
| 39 | Supplying of A.C. Ceiling fan(1200mm sweep) with all accessories as required.(Make: Bajaj/ Usha/ Orient/Crompton or equivalent to ISI standard). |
| 40 | Supplying and fixing stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. As required.etc. |
| 41 | Installation, testing and commissioning of ceiling fan, including down rods and wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc. as required. |
| 42 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 415 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB /RCCB /Isolator) |
| 43 | 4 way, Double door |
| 44 | Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, 10 kA, \"C\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 45 | Single Pole |
| 46 | Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 47 | 40 Amps, 2 Pole Isolator |
| 48 | Dismantling of following way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But with MCB/RCCB/Isolator). |
| 49 | 4 way, Double door |
| 50 | Dismantling of following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 51 | 40 Amps, 2 Pole Isolator |
| 52 | Dismantling and fixing 5 amps to 32 amps rating, 240/415 volts, 10 kA, \"C\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 53 | Single Pole |
| 54 | Dismantling of old wooden or PVC switch Boards of all sizes and ratingsfor domestic and Industrial use with high quality Energy efficient rectangular white or other colour and wall mounted heat resistant of 500 Ohms ,shockproof, premium quality and long term durable PVC Electrical Switch Boards of Dimensions: (220 X 160 X 45)mm etc. as required. |
| 55 | Dismantling of PVC box on surface or in recess, including providing and fixing 6 pin5/6 & 15/16amps socket outlet and 15/16 amps piano type switch, connection, painting etc. as required. |
| 56 | Dismantling of PVC box on surface or in recess, including providing and fixing 3 pin5/6 amps socket outlet and 5/6 amps piano type switch, connection, painting etc. as required. |
| 57 | Dismantling of Ceiling fan and painting the same with one or more coats of spray painting with synthetic enamel paint of approved brand and manufacture to give an even shade, including cleaning of surface with detergent and replacing the daaged rubber reels, nuts and bolts with washers and safety pins refixing the same as required. |
| 58 | Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required. |
| 59 | Providing and laying earth connection FRL from earth electrode with 4.00 mm dia copper wire in 15 mm dia G.I. pipe from earth electrode including connection with copper thimble excavation and re-filling as required. |
| 60 | Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthingas required. |
| 61 | Supplying and fixing brass batten/ angle holder including connection etc. as required. |
| 62 | Supplying ofLED Lamp 9W (MAKE : WIPRO TEJAS 9W ) (Make: Bajaj/ Havells /Usha /Orient/Crompton or equivalent to ISI standard) |
| 63 | Supplying and fixing of AC LIGHT DUTY wall mounting fan (300mm sweep) (MAKE USHA DOMINAIRE WALL FAN) with high speed swing and build in regulator with all accessories etc as required. (MAKE : WIPRO TEJAS 9W ) (Make: Bajaj/ Havells /Usha /Orient/Crompton or equivalent to ISI standard) |
| 64 | Supplying and fixing rewirable porceline with fuse unit of 32 to 40 amps on energy meter board. |
| 65 | Supplying and fixing of Wooden meter board of Size 10\" X 12\" for fixing of Energy meter or equivalent to ISI standarad. |