| 1 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, for all lift, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. |
| 2 | All kinds of soil. |
| 3 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 and for all lif. |
| 4 | Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge. |
| 5 | Nominal concrete 1:3:6 or richer mix (including equivalent design mix) |
| 6 | Providingandlayinginpositioncementconcreteof specified grade excluding the cost of centering and shuttering - All work up to plinth level : |
| 7 | 1:3:6 (1Cement : 3 coarse sand (zone-Ill) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 8 | 1:4:8 (1Cement : 4 coarse sand (zone-Ill) derived from natural sources: 8 graded stone aggregate 40 mm nominal size derived from natural sources) |
| 9 | Providing and laying cement concrete in retaining walls, return walls, walls (any thickness)includingattachedpilasters,columns,piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor etc., up to floor five level, excluding the cost of centering, shuttering and finishing: |
| 10 | 1:2:4 (1Cement : 2 coarse sand (zone-Ill) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 11 | Reinforced cement concrete work in walls (any thickness),including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor fivelevel,excludingcost of centering,shuttering, finishingand reinforcement: |
| 12 | 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 13 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15 degree landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources). |
| 14 | Providing,hoisting and fixing above plinth level up to floor five level precastreinforcedcementconcreteworkinstringcourses,bands, copings,bedplates,anchor blocks,plain window sills and thelike, including the cost of required centering, shuttering but excluding cost of reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources). |
| 15 | Steelreinforcement forR.C.C.workincludingstraightening,cutting, bending, placing in position and binding all complete above plinth level. |
| 16 | Thermo-Mechanically Treatedbars of gradeFe-500D or more. |
| 17 | Centering and shuttering including strutting, propping etc. and removal of form for |
| 18 | Foundations,footings,basesof columns,etc.formass concrete |
| 19 | Walls (anythickness)includingattachedpilasters, butteresses, plinth and string courses etc. |
| 20 | Shelves (Cast in situ) |
| 21 | Lintels,beams,plinthbeams,girders,bressumersand cantilevers |
| 22 | Columns, Pillars, Piers, Abutments, Posts and Struts |
| 23 | Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. |
| 24 | Electric resistance or induction butt welded tubes |
| 25 | Structural steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. |
| 26 | Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. |
| 27 | Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. |
| 28 | Ingratings,frames,guardbar,ladder,railings,brackets, gates and similar works |
| 29 | Providing and laying hollow cement concrete block walling 100mm thick consisting hollow block of size 400 x 100x200mm of mix 1:3:6(1cement :3 coarse sand:6 graded stone agg. 10mm nominal down size) having a crushing strength of 3.5N/mm2 at 28 days as per I.S. 2185 (Part-I) 1979 laid in cement mortar 1:6(1cement : 6 coarse sand). |
| 30 | Upto floor five level |
| 31 | Providing and laying hollow cement concrete block walling 200mm thick consisting hollow block of size 400 x 200x200mm of mix 1:3:6(1cement :3 coarse sand:6 graded stone agg. 10mm nominal down size) having a crushing strength of 3.5N/mm2 at 28 days as per I.S. 2185 (Part-I) 1979 laid in cement mortar 1:6(1cement : 6 coarse sand) |
| 32 | Upto floor five level |
| 33 | Providing and fixing pre-painted galvalume (PPGL) steel profile sheets AZ-150 of brand Tata Bluescope steel, Everest Industries Ltd., JSW Steel Ltd., Jindal India Ltd. or equivalent (size, shape and pitch of corrugation as approved by Engineer-In- charge) 0.50mm (+0.50%) total coated thickness with aluminium zinc coating 150 grams per sqm as per IS:277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns, sheet should have protective guard film of 25 micron minium to avoid scratches during transportation and should be supplied in single length up to 12 metres or as desired byEngineer-In-Charge. The sheet shall be fixed using self drilling/ self tapping aluminium screws (Xylan) of size (5.5X55mm) with EPDM seal, complete up to any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. |
| 34 | \"Providing and fixing pre-painted galvalume (PPGL) steel profile sheets AZ-150 of brand Tata Bluescope steel, Everest Industries Ltd., JSW Steel Ltd., Jindal India Ltd. or equivalent roofing acessories 0.50mm (+0.50%) total coated thickness with aluminium zinc coating 120 grams per sqm as per IS:277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping aluminium screws complete.\" |
| 35 | Ridge plain(500-600 mm) |
| 36 | Extra for providing and fixing wind ties of 40x 6 mm flat iron section. |
| 37 | 12 mm cement plaster of mix: |
| 38 | 1:4(1 cement: 4 fine sand) |
| 39 | Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required : |
| 40 | W.C. pan with ISI marked white solid plastic seat and lid |
| 41 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: |
| 42 | White Vitreous China Wash basin size 550x400 mm with a pair of 15 mm C.P. brass pillar taps |
| 43 | Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. |
| 44 | Semi rigid pipe32 mm dia |
| 45 | Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. |
| 46 | Providing and fixing PTMT towel ring trapezoidal shape 215 mm long, 200 mm wide with minimum distances of 37 mm from wall face with concealed fittings arrangement of approved quality and colour, weighing not less than 88 gms. |
| 47 | Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour. |
| 48 | 600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 gms. |
| 49 | Providing and fixing uplasticised PVC connection pipe with brass unions : |
| 50 | 45 cm length15 mm nominal bore |
| 51 | Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet : |
| 52 | 100 mm diameter |
| 53 | Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931 : |
| 54 | 15 mm nominal bore |
| 55 | Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931 |
| 56 | 15 mm nominal bore |
| 57 | Providing and fixing PTMT pillar cock of approved quality and colour. |
| 58 | 15 mm nominal bore, 125 mm long foam flow, weighing not less than 120 gms |
| 59 | Providing and fixing CP brass two way bib cock (Jaquar or equivalent) of approved quality. |
| 60 | 15mm nominal bore |
| 61 | Providing and fixing C. P. brass Health Faucet of approved quality with 1.0/1.2m flexible tube and hook complete or as per the direction of E-in-Charge(Jaquar make) approved brand (Model No. ALD-573) |
| 62 | 15 mm dia |
| 63 | Providing and fixing aluminium sliding door bolts, ISI marked anodised (anodic coating not less than grade AC 10 as per IS: 1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete : |
| 64 | 250x16 mm |
| 65 | Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete : |
| 66 | 150x10 mm |
| 67 | 100x10 mm |
| 68 | Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete : |
| 69 | 100 mm |
| 70 | 75 mm |
| 71 | Providing and fixing in position eaves or facia board with 12mm thick WPC board of SIR Gold or equivalent manufacturer and 30cmwide including nailing etc complete as per the direction of Engineer-in-charge. |
| 72 | Providing and fixing factory made P.V.C. door frame of size 50x47 mm with a wall thickness of 5 mm, made out of extruded 5 mm rigid PVC foam sheet, mitred at corners and joined with 2 Nos of 150 mm long brackets of 15x15 mm M.S. square tube, the vertical door frame profiles to be reinforced with 19x19 mm M.S. square tube of 19 gauge, EPDM rubber gasket weather seal to be provided through out the frame. The door frame to be fixed to the wall using M.S. screws of 65/100 mm size, complete as per manufacturer\"s specification and direction of Engineer- in-Charge. |
| 73 | Providing and fixing factory made panel PVC door shutter consisting of frame made out of M.S. tubes of 19 gauge thickness and size of 19 mm x 19 mm for styles and 15x15 mm for top & bottom rails. M.S. frame shall have a coat of steel primers of approved make and manufacture. M.S. frame covered with 5 mm thick heat moulded PVC \"C\" channel of size 30 mm thickness, 70 mm width out of which 50 mm shall be flat and 20 mm shall be tapered in 45 degree angle on both side forming styles and 5 mm thick, 95 mm wide PVC sheet out of which 75 mm shall be flat and 20 mm shall be tapered in 45 degree on the inner side to form top and bottom rail and 115 mm wide PVC sheet out of which 75 mm shall be flat and 20 mm shall be tapered on both sides to form lock rail. Top, bottom and lock rails shall be provided both side of the panel. 10 mm (5 mm x 2 ) thick, 20 mm wide cross PVC sheet be provided as gap insert for top rail & bottom rail, paneling of 5 mm thick both side PVC sheet to be fitted in the M.S. frame welded/ sealed to the styles & rails with 7 mm (5 mm+2 mm) thick x 15 mm wide PVC sheet beading on inner side, and joined together with solvent cement adhesive. An additional 5 mm thick PVC strip of 20 mm width is to be stuck on the interior side of the \"C\" Channel using PVC solvent adhesive etc. complete as per direction of Engineer-in-charge, manufacturer\"s specification & drawing. |
| 74 | 30 mm thick plain PVC door shutters |
| 75 | Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length ( hold fast lugs or dash fastener shall be paid for separately). |
| 76 | Superior hardwood Cart-II (A) |
| 77 | Chequerred precast cement concrete tiles 22 mm thick in footpath & courtyard, jointed with neat cement slurry mixed with pigment to match the shade of tiles, including rubbing and cleaning etc. complete, on 20 mm thick bed of cement mortar 1:4 (1 cement: 4 coarse sand). |
| 78 | Dark shade pigment using ordinary cement |
| 79 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. |
| 80 | Fixed to openings /wooden frames with rawl plugs screws etc. |
| 81 | Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre of approvedbrandandmanufacture,includingapplyingadditionalcoats wherever required to achieve even shade and colour. |
| 82 | Two coats |
| 83 | Finishing walls with textured exterior paint of required shade: |
| 84 | New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including priming coat of exterior primer applied @ 2.20kg/10 sqm |
| 85 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade: |
| 86 | Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture |