| Sl. No. | Item Description |
| 1 | Removing excavated material (debries obtained from demolition) n exc 50m and depositing where directed at a level n exc 1.5m above the starting point complete all as specified and directed. |
| 2 | M&L for PCC 1:3:6 type C-1 (using 20mm graded crushed stone aggregate) as in beed block for hold fast and filling in back of chowkatthe like including weathering, slightly rounded or chamfered angles and throating complete all as specified and directed. |
| 3 | M&L forProviding, cement concrete1:2:4type-B1 using 20mm graded crushed stone aggregate in lintels upto 1.5m clear span, cills, steps;roof padding, seismic and other similar bands,plinth courses, string courses,lacing courses, parapets and railings upto 60 cm in height,copings, kneelers, apex stones,bed plates, kerbs not provided for in Item 04028, water troughs and the like including weathering, slightly rounded or chamfered angles and throating, as directed complete all as specified and directed. |
| 4 | M&L forreinforced cement concrete design mix M 25 grade using 20 mm graded crushed stone aggregate asinSlabs supported on walls,beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the likecomplete all as specified and directed. |
| 5 | M&L forreinforced cement concrete design mix M 25 grade using 20 mm graded crushed stone aggregate asin chajja , shelves and like etc.complete all as specified and directed. |
| 6 | Supply only polyester triangular fibres as secondary reinforcement in all types of concrete and mortars as approved by GE. |
| 7 | Supply only integral water proofing compound liquid grade conforming to IS-2645 complete all as specified and directed. |
| 8 | M&L for brickwork with old size fly ash bricks, straight or curved on plan exc 6m mean radius, built in cement mortar 1:6 complete all as specified and directed. |
| 9 | M&L for brickwork with old size fly ash bricks, straight or curved on plan to any radius as in half brick thick walls, built in cement mortar 1:4 complete all as specified and directed. |
| 10 | M&L for Cutting holes into or through brick walls built in cement mortar or cement lime mortar and making good in cement mortar 1:3 or cement concrete 1:2:4 type B-l as required exc 150sqcm but not exc 400sqcm complete all as specified and directed. |
| 11 | Making good under cills or over arches, lintels and bressummers. including all pinning in cement mortar 1:6 when necessary complete all as specified and directed. |
| 12 | M&L for Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work;not exceeding 200mm thick (Horizontal or sloping) rough finished surface flat complete all as specified and directed. |
| 13 | M&L for formworkto chullah hoods, chajjas, troughs and similar items in cluding edgescomplete all as specified and directed. |
| 14 | S&F 35mm thick 2nd class hard wood glazed and skeleton factory made shutter open rebated and prepared to receive glass, gause etc. (without sash bars) edges of framing plain chamferred or rounded, fitted with cut and mitred beads for securing glass etc, size of members of shutters as specified in SSR part-I, Sec-08, Clause 8.24(a), kiln seasoned and chemically pressure treated complete all as specified and directed. |
| 15 | S&F 30mm thick factory made flush shutter, solid core construction with block board core and plywood face panels, commercial type on both sides kiln seasoned and chemically pressure treated complete all as specified and directed. |
| 16 | Taking down chowkat or frame with shutter (without taking off shutter from the frame) area not exc. 1.5sqm each, including cutting holes for removing the hold fast,making good disturbed surfaces and removing materials from site of work complete all as specified and directed. |
| 17 | Taking down chowkat or frame with shutter (without taking off shutter from the frame) exc. 1.5 sqm and n.exc 4 sqm each, including cutting holes for removing the hold fast, making good disturbed surfaces and removing materials from site of work complete all as specified and directed. |
| 18 | S&F Factory Made Solid PVC Moulded Door Shutter with wood free EPS , 28 to 30mm thick (stiles), with 2, 4, or 6 raised panel design with 2mm thick Moulded PVC Sheet on the front face & 2mm plain colour PVC sheet on back face, supplying & fixing in frame at site as per specification & drawing complete all as specified and directed. |
| 19 | S&F Solid PVC frame (Single Rebated) of size 60mm x 30mm made out of solid PVC foam with homogenous fine cellular structure having smooth outer integral skin with suitable metal stiffner and fixed with 100 x 8 sheet metal CSK screws complete all as specified and as shown on drawing.(Note :- Door frame shall be water proof, termite proof, elegant and should have excellent screws holding strength to fix hinges and hold doors properly for a long life)complete all as specified and directed. |
| 20 | S&F 200mm aluminium anodised barrel tower bolts of extruded sectioncomplete all as specified and directed. |
| 21 | S&F 150mm aluminium anodised barrel tower bolts of extruded sectioncomplete all as specified and directed. |
| 22 | S&F 300 mm long aluminium alloy, anodised,sliding door bolt with hasp,staple (bolt type) andfixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed complete all as specified and direcetd. |
| 23 | S&F 100mm Butt hinges,medium weight, cold rolled mild steel,complete all as specified and directed. |
| 24 | S&FContinuous (piano) hinges Width of flaps (when open) in 30mm,mild steel, bright finish or electrogalvanised complete all as specified anddirected. |
| 25 | S&F 150mm size aluminium handle cast typecomplete all as specified and directed. |
| 26 | S&F in repairtubular towel rail 20mm dia type brass chrormium plated 600mm long between flanges complete all as specified and directed. |
| 27 | S&F Ball catches with 8mm dia steelball, and brass body and strikingplate including letting in andfixed complete all as specified anddirected. |
| 28 | S&F aluminium (die Cast) Door closer hydraulically regulated,universal type,suitable for door shutters up to 700 mm in width and of weight not more than 35 kg and fixed complete all as specified and directed. |
| 29 | S&F Stainless steel wire cloth. 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staplescomplete all as secified and as directed |
| 30 | M&L for MS framed work such as grills,gratings, etc.. with ends of bars shouldered and/or riveted,or forged into spikes; framed guard bars; barred iron doors;ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165complete all as specified and directed. |
| 31 | M&L forTMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed. |
| 32 | M&L forTMT bars5mm dia and over upto and including 10mm dia in stirrups, spacers and binders cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed. |
| 33 | S&F roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc conforming to Fe -410-W(Gde-E-250) quality-A. complete all as specified and directed. |
| 34 | S&F MSframed work confirming to Fe 410 -W quality Bas in doors or gates of angle or other section with gusset plates, rails,braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete |
| 35 | M&L for 1.25mm thickpressed steel door frame of size 165mm x 60mm with one or more rebates including necessary , hinges, lock strike plate, fixing lugsetc complete as specified. |
| 36 | M&Lfor 1.25mm thickpressed steel door frame of size 105mm x 60mm with one or more rebates including necessaryfixing lugs , hinges, lock strike plate etc complete all as specified and directed. |
| 37 | S& F powder coated GI T-section of size 1\"x1\" (25x25mm,19 gauge or 1mm thick) in square pattern of grid size 2\"x2\"(600x600mm). The frame work is supported from the ceiling with the help of \"J\" hook and GI wire / ms rod of 4mm dia of required size to maintain proper level etc.The frame work is supportedon side walls with the use of powder coated GI L section of size 1\"x1\" (25x25mm) angle complete all as per manufacturer instructions, specified and directed. |
| 38 | M&L for anodised aluminium snap grid (SIZE-605x605MM) frame work for false ceiling complete all as specified and directed. |
| 39 | S&F Hangers 6 mm dia. G.I. (upto 1200mm length) adjusting level fixed to roof slabs by means of ceilling cleats made out of G.I. flat 40 x 3 mm size 60mm long and expansion hold fasteners 12.5mm dia. 40mm long complete all as specified and directed. |
| 40 | S&F Hard drawn steel wire fabric in available size Weight per square metre Not exc4 kg fixed as in tank caging incl welding, riveting, framing etc complete all as specified and directed. |
| 41 | S&F Pre- painted coloured trapezoidal profiled Galvalume/ Zincalume sheet with min thickness 0.50mm TCT confirming to IS - 513(AZ-150 GSM, Al Zn allay metalic coating with 550 Mpa yield stress as per AS-1397) as in roof covering/cladding towall, fixed with self tapping screws colour exterior coat of silicon modified polyster/BHP x RW paint system 20 micron top coat applied over 5 micron primer and 5 micron polyster back coat applied over 5 micron primer , all fixed with galvanized self drilling self tapping fastner (12-14 x 55 with EPDM seals) complete all as specified and directed. |
| 42 | S&F Pre- painted coloured plain sheet Galvalume/ Zincalume sheet with min thickness 0.50mm TCT confirming to IS - 513(AZ-150 GSM, Al Zn allay metalic coating with 550 Mpa yield stress as per AS-1397) as in roof covering/cladding towall, fixed with self tapping screws colour exterior coat of silicon modified polyster/BHP/ XRW paint system 20 micron top coat applied over 5 micron primer and 5 micron polyster back coat applied over 5 micron primer , all fixed with galvanized self drilling self tapping fastner (12-14 x 55 with EPDM seals) complete all as specified and directed. |
| 43 | Taking down eaves gutters and rainwater pipes (any size or pattern), including all fittings,heads, shoes, bends, swan-necks,etc., including cleaning or refixing or removal to Store (measured overall as fixed along the centre line over fittings and accessories)complete all as specified and directed. |
| 44 | S&F 4 mm thick designer Non asbestos fiber cementbuilding boards, fixed or laid /inserted totimber /GI /Aluminium frame-work with screws complete all as specified anddirected. |
| 45 | M&L 19/20mm thick prelaminated particle board,exterior grade, solid core,medium density general purposes type with commercial face veneers type \"BB\"complete all as specified and directed |
| 46 | M&L for granite (of any type) stone slab 20mm thick (table rubbed and polished), in skirting, Kitchen platform/dado etc laid over and including 15mm thick renderingincement mortar 1:6 beded, jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including grinding the edges half round and polishing including etccomplete all as specified and directed. |
| 47 | M&L for 75mm thick PCCtype C2,1:3:6 using 40mm graded crushed stone aggregateas in floor/plinth protection finishing the concrete surfaces even and smooth without using extra cement complete all as specified and directed. |
| 48 | M&L for 75mm thick PCCtype D2,1:4:8 using 40mm graded crushed stone aggregateas in sub base of PCC floorcomplete all as specified and directed. |
| 49 | M&L for 40mm thick cement concrete type B-1, 1:2:4 (using 20 mm graded crushed stone aggregates)as on roof top finished the surface to receive the water proofing treatment completeall as specified and directed. |
| 50 | M&L for rendering 10 mm thick in cement mortar 1:4 on concrete surface mixed with water proofing compound as per manufacture instruction etc complete all as specified anddirected. Notes : WPC shall be measured and paid seperately under respective item of this schedule. |
| 51 | Taking down cement plaster on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water, etc. complete all as specified and directed. |
| 52 | S&F 4.0mm thick Figured glass, pin head type and glazing with oil putty in squares exc 0.5 sqm in each panecomplete all as specified and directed. |
| 53 | M&L for sheet glass, 4.8mm thick, ordinary quality and glazing with oil putty/aluminium beading in squares exc. 0.50 Sqm each paneground or obscured or frosted, on one side complete all as specified and directed. |
| 54 | M&Lfor preparation of old paintedwood/wooden surface of any description over 10cm width or girth and applying one coats of synthetic enamel paint (1st grade quality) complete all as specified and directed. |
| 55 | M&Lfor preparation of untreated new wood/wooden surface of any description over 10cm width or girth and applying two coats of synthetic enamel paint (1st grade quality) over a coat of pink primer complete all as specified and directed. |
| 56 | Taking up or down steel tubing and connections,including cleaning for refixing or removal to store bore of pipe 15 mm complete all as specified and as directed |
| 57 | Taking up or down steel tubing and connections,including cleaning for refixing or removal to store bore of pipe 20 mm complete all as specified and as directed |
| 58 | Dismantling water tanks and removing to store exc 250 ltr but not exc 500 ltr capacity complete all as specified and as directed |
| 59 | S&F rotational moulded PVC water storage tank 500 ltrs capacity conforming to IS-12701(1989) cylindrical vertical type double-layered with closed top (thereated) including inlet,outlet and wash out holes of approved make hoisted and fixed in position all as specified in SSR Part I etc completge all as specified and directed. |
| 60 | S&Ffancy type with long shank and cup (concealed type) chromium plated stop valve cast copper allow screw down high pressure with crutch or butterfly handle screwed both end form iron pipe or for union and fixed of size 15mm dia complete all as specified and directed. |
| 61 | S&F in repairGun metal globe or gate valves with iron wheel head screwed both ends for iron pipe 20mm bore and fixed as in repair complete all as specified and directed. |
| 62 | S&F ball valves for 20mm bor dia of pipehigh pressure of PTMT with epoxy coated Aluminium rod & highdensity plastic ball screwed for iron pipe and fixed. (Minimum weight 15mm-142gms/ 2 0mm-210gms./25mm-455gms/ 40mm - 690 gms) complete all as specified and directed. |
| 63 | S&FPVC connectionspipe ,15mm dia size with PTMT nuts of length 450mm complete all as specified and directed. |
| 64 | S&F 75mm PVC (SWR) as in drain pipes single socketed in any length with rubber ring jointslaid in trenches or in floors complete all as specified and directed. |
| 65 | S&F 110mm PVC (SWR) as in drain pipes single socketed in any length with rubber ring jointslaid in trenches or in floors complete all as specified and directed. |
| 66 | S&F 110mm PVC (SWR)pipes single socketed in any length with rubber ring joints fixed to wallscomplete all as specified and directed. |
| 67 | S&F 75mm bore PVC (SWR) bends with oval access door incl rubber ring joints any radius complete all as specified and directed. |
| 68 | S&F 75mm bore PVC (SWR) bends with rubber ring joints any radius complete all as specified and directed. |
| 69 | S&F110mm bore PVC (SWR) bends with rubber ring joints any radius complete all as specified and directed. |
| 70 | S&F75mm bore PVC (SWR) branch piece,single (single Y) equal or unequal complete all as specified and directed. |
| 71 | S&F110mm bore PVC (SWR) branch piece,single (single Y) equal or unequal complete all as specified and directed. |
| 72 | S&F in repair PVC (SWR) floor trap 75mm dia , plain with grating including jointing to waste pipe in cement concrete 1:2:4 type B1 using 20mm graded crushed stone aggregate incl water leak proofcomplete all as specified and directed. |
| 73 | S&F in repairs PVC (SWR) gully trap 125/110 mm, setting and jointing with solvent cement etc complete all as specified and directed. |
| 74 | S&F in repair sinks made of stainless steel01mm thick kitchen or laboratory with plugs, washers and wastes;including bedding in cement mortar on to dwarf wall or including fixing cantilever brackets and connecting union to pipe,overall size 495mm x 420mm bowl size 410mm x 330mm x 160mmcomplete all as specified and as directed |
| 75 | S&F in repair 600mmx450mm bevelled edge mirror of selected quality glass, mounted on 6mm thick AC building board or commercial plywood incl 40 mm wide acrylic beading and fixed to wooden plugs with chromium plated brass screws and cup washers complete all as specified and directed. |
| 76 | Demolition of Brickwork or stone/boulder masonry, built in cement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings,dressed stonework and precast concrete articles complete all as specified and directed. |
| 77 | Dismantling of stone slabs and tiles of any description or thickness in floors, approachs, dado/Partitions laid bedded and pointed in any mortaretc complete all as specified and directed |
| 78 | Demolition of cement concrete( un-reinforced)in ground floorand paving n.exc 15 cm thickness( below or above ground level) complete all as specified and directed. |
| 79 | Dismantling structural steel work including doors, gates but excluding framed truss etc. complete all as specified and directed. |
| 80 | Dismantling plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings incl ridges, hips and valley gutter complete all as specified and directed. |
| 81 | Dismantlingwall and ceiling board( fiber, pulp, insulation, etc.) or insulation board/slab/ blankets, any thickness, including cover fillets complete all as specified and directed. |
| 82 | Dismantling of 100mm dia cast iron or reinforced concrete drain pipes, jointed in cement mortar and taking out of trenches, if required complete all as specified and directed. |
| 83 | M&L fornewly plastered surface of wall appying two coat of white or tinted oil bound distemper over one coat of alkali resistant priming paint including 02mm thick wall care putty etc complete all as specified and as directed. |
| 84 | M&L for apply one coat of oil bound distemper over a coat of primer over 01mm thich plaster of paris over non asbestos ceiling boardsetc complete all as specified and as directed. |
| 85 | M&L for powder coated(minimum thickness of powder coating 50 micron)anodised aluminium frame for doors,windows, ventilators with one or more rebates including joining cleat for fixing etc complete all as speecified and directed.Note : (i) Weight of Aluminium sections as per actual or as per IS or as per Manufacturer which over is less, shall only be considered for payment.(ii) Cost of all the items/ accessories required for the entire completion of the work shall be deemed to be included in the quoted rate. However glass panes and wire cloth shall be measured and paid separately under respective items. (iii) The accessories (Aluminium mongries etc) required to be provided for window, vents and doors as per directions of Engineer-in-charge shall be provided but weight for the same shall not be considered and no extra cost will be paid. |
| 86 | M&L for powder coated aluminium door shutters,aluminium section weighing 0.55 kg/m including necessary joining cleats,glazing clips, ruber neoprene packing,handles 2 Nos in each door, hinges,anodised aluminum snap beading screws etc. complete all as speecified and directed. |
| 87 | S&F Powder coated aluminium (minimum thickness of powder coating 50 micron) for shutters of doors, partitions,windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber/neoprene gasket required (Fittings shall be paid for separately) with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved makeonforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc.Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snapbeading for glazing/ paneling, C.P. brass/ stainless steel screws all complete as per architectural drawings and the directions of Engineer-in-charge. Note : (i) Weight of Aluminium sections as per actual or as per IS or as per Manufacturer which over is less, shall only be considered for payment.(ii) Cost of all the items/ accessories required for the entire completion of the work shall be deemed to be included in the quoted rate. However glass panes and particle board shall be measured and paid separately under respective items. (iii) The accessories requiredfor partition as per directions of Engineer-in-charge shall be provided but weight for the same shall not be considered and no extra cost will be paid. |
| 88 | M&L for Machine cut kota stone slab flooring 20-25mm thick over and including cement screed base 20mm thick in cement mortar 1:6, laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishingcomplete all as specified and directed. |
| 89 | M&L for machine cut kota stone in riser, dado, steps, skirting etc20-25mm thick of size over and including 10mm thick cement rendering in cement mortar 1:4 laid & jointed with grey cement slurry mixed with pigment to match the shade of slab including granite ( mirror) polishing complete all as specified and directed. |
| 90 | M&L for 25mm thick cement concrete type B-0, 1:2:4 (using 12.5 mm graded crushed stone aggregates)as in flooring, finished the surface even andrough completeall as specified and directed. |
| 91 | Roughening the surfaces of old concrete floor by picking, sweeping cleaning and washing down with water to remove dust, etc and brushing neat cement slurry with 3.0 kg of cement per sqm complete all as specified and directed, |
| 92 | M&L for Glazed ceramic tiles coloured 300mmx 450mm , 6 to 7 mm thick as in skirting / dado, set and jointed in neat cement slurry and pointed in white or colour cement to match over and including 10 mm thick rendering in cement mortar 1:4 on fair faces of brick work or concrete surface etc complete all as specified andand as directed |
| 93 | M&Lfor Non Skidceramic tiles (coloured) 7 to 8 mm thick , (square / rectangular) area of each tiles exceeding 0.11 sqm but not exceeding 0.18 sqm as in floor etc, set and jointed in neat cement slurry and pointed with white or coloured cement to matchover and including screed bed or bedding layer 15mm thick in cement mortar 1:6for laying floor finishes etc complete all as specified and directed |
| 94 | M&Lfor Non Skidceramic tiles (coloured) 7 to 8 mm thick , (square / rectangular) area of each tiles exceeding 0.18 sqm but not exceeding 0.38 sqm as in dado/skirting etc, set and jointed in neat cement slurry and pointed with white or coloured cement to matchover and including rendering layer 10 mm thick in cement mortar 1:4etc complete all as specified and directed |
| 95 | M&Lfor Non Skidceramic tiles (coloured) 7 to 8 mm thick , (square / rectangular) area of each tiles exceeding 0.18 sqm but not exceeding 0.38sqm as in floors etc, set and jointed in neat cement slurry and pointed with white or coloured cement to matchover and including screed bed or bedding layer 15 mm thick in cement mortar 1:6for laying floor finishes etc complete all as specified and directed |
| 96 | M&L for providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5 mm), including making drainage opening wherever required completeall as specified and directed. |
| 97 | M&L for providing and laying 60mm thick factory made chamfered edge cement concrete paver block of M-35 grade with approved colour, design & pattern as in footparth, parks,lawns, drive ways or light traffic parking etc., of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of fine sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand; completeall as specified and directed. |
| 98 | M&L for rendering 5mm thick on ceiling of chhajja etc in cement mortar 1:3 on fair faces of concrete surface finishing surfaces even and smooth without using extra cement complete all as specified and directed. |
| 99 | M&L for rendering 15 mm thick in cement mortar 1:6 on fair faces of brick work or concrete surfaces and finishing surfaces even and smooth without using extra cement complete all as specified and directed. |
| 100 | M&L forrendering 15 mm thick in two layers 10mm +5mm in cement mortar 1:4 on external surfaces of brick work or concrete surfaces with using WPC finishing the surfaces even and smooth without using extra cement complete all as specified and directed.Note:- WPC will be measured and paid separately under respective item of this schedule. |
| 101 | M&L for preparation of new surfaces and applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces over 1mm thick wall care putty complete all as specified and directed. |
| 102 | M&L for complete removal of old plastered surface of walls and applying two coat of oil bond distemper white or any tint over a coat of primer over 01mm thick wall care putty etc complete as specified and directed. |
| 103 | M&L for complete removal of old existing treatement of internal wall and appying two coat of oil bound distemper over a coat primer over 02mm thick wall care putty complete all as specified and as directed |
| 104 | M&L preparation of old plastered surfacesof ceiling and chajjas and applying one coat white wash complete all as specified and directed. |
| 105 | M&L for preparation of old surfaces by complete removal of existing treatment and applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over 01mm thick wall care putty complete all as specified and directed. |
| 106 | M&L for preparation of new undecorated surface of ceiling and applying three coats of white wash complete all as specified and directed. |
| 107 | Supply and laying of CPVC pipes outer diameter 20mm SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified and directed. |
| 108 | Supply and laying of CPVC pipes outer diameter 25mm SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified and directed. |
| 109 | S&F in repair bib tap fancy type cast copper alloy chromium plated with crutch or butterfly handle screwed down screwed for iron pipe or brass ferrule or fixed for 15 mm dia bore pipe complete all as specified and directed. |
| 110 | S&F in repair 15 mm bore pillar taps fancy type (long neck) cast copper alloy with hot & cold mixturechromium plated screwed down high pressure with or without letter hot or could with long screwed and shanks and fly nuts screwed for iron pipes complete all as specified and as directed. |
| 111 | S&F 0.63 mm thick stainless steel plate rack of overall size 24\"x36\"x10\" of standard quality and shape complete all as specified and directed. |
| 112 | S&F in repairLow density polyethylene(LDPE) pipes bore of pipe in 32mm of pressure rating6 kgf/sq. cmcomplete all as specified and directed |
| 113 | S&F in repair Brass chromium plated shower rose 125mm size with or without swivel joints of standard size including fixing to 15mm steel pipe or union complete all as specified and as directed. |
| 114 | S&F in repairs coloured vitreous china wash down water closet (anglo-indian type) Semi Pedestal Pattern white (excluding flushing cistern & flush pipe) incl connection to out going pipe, and flushing pipe complete all as specified and as directed. |
| 115 | S&F in repair PVC valveless double syphonic action type flushing cistern low level of 10 Ltr capacity white with inlet ball valve, float, flushing bend & handle including brackets, suitable for both Indian Type Water Closet & Europeon Type Water closet including brackets & connection to pipe etc complete all asspecifiedand directed. |
| 116 | S&F Vitreous china WHB 550x400mm size white flat backexcluding taps,waste, chain and plug and porcelain stopper but including bracketsincl cutting or pinning ends of brackets (including waste pipe) incl Waste coupling of brass chromium plated (32 mm dia) (half or full threaded) complete all as specified and directed. |
| 117 | Demolition of cement concrete (reinforced )ofany description and in any position not exceeding 15 cm thick, including removal complete all as specified and directed. |
| 118 | S&F in repair mild steel Helical door spring 300mm long ordinary rat tail type incl roaller & roller plate complete fixed with screws to wooden frames or with welding to steel frames complete all as specified and directed. |
| 119 | Taking down existing un-sreviceable water proofing treatment from roof slab and cleaning the roof by wire brush and removing WPT felt beyond the MOD premises etc. cement plaster on brick or stone walls, etc.complete all as specified and directed. |
| 120 | S&F stainless steel decorative curtain rod of 25mm bore with a pair of fancy type golden colour bracket complete all as specified and directed. |
| 121 | S&F finial fancy type for curtain rod in pair etc complete all as specified and as directed. |
| 122 | S&F bracket for curtain rod in pair etc complete all as specified and as directed. |
| 123 | M&L for surface preparationfree from frost, surface laitance and contamination free from loose aggregate or other sharp protrusions with fairly smooth finish for applicaion of water proof coating prime the surface with water complete all as specified and directed. |
| 124 | M&L for waterproofing coating by providing and applying Fosroc Brushbond Roof Guard of FOSROC or equivalent of SIKA/STP , a single component High build fibre Reinforced Acrylic waterproofing render for roofing system applied by brush, at three coats at minimum dry film thickness of 1 mm, cured by reaction with atmospheric moisture to give a tough elastomeric waterproof membrane complete all as per manufacturer specification, specified and directed.Solid Content - 70%, Tensile strength ASTM D 412-1.10 Mpa, Elongation ASTM D12-100%, Resistance to ageing due to - 1000hours, UV radiation ASTM D4587 E - No Change, Rapid Chloride Penetration ASTM c 1202 - Very low, Pull off adhesion ASTM D541 - 0.92 Mpa, Resistance to Algae growth ASTM D 5589-97 - Passes, Zero rating, Permeability (mm) (BSEN 12390 part 8) -n 5.0, Water vapour transmission (ASTM E 96) - 6.0g/m2h |
| 125 | M&L for repairing of Cracks & Honeycomb Treatment by Injection Grouting by Identify the cracks and joints, shall be chased open into \"U\" groove shape.The surface of the groove shall be suitably prepared as require to apply the mortar. Apply Nitibond ofSBR Latex of Make Fosroc Nitobond or equivalent of SIKA/ STP and sealed with Shrinkage controlled, polymer modified, fiber reinforced cementitious repair mortar, Fosroc Renderoc SP40 including fixing PVC nozzle up to required depth , injection grouting to be done with cement slurry admixed with expanding grout admixture cebex 100 of Make Fosroc Nitobond or equivalent of SIKA/ STPto be mixed @ 225 gm per bag of cement complete all as specified and as directed . |
| 126 | M&L for bore packing to be done at pipe entries by forming properformwork and filling the gap with non-shrinkable cementitious grout conbextra GP2 of Make Fosroc or equivilant of SIKA/ STP and sealed with epoxy/polyester sealant complete all as specified and as directed . |
| 127 | Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc.removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc as per existing specification complete all as specified and directed. |
| 128 | Taking down of Old MCB DB / control box any type any size by disconnecting electric connection carefully SPN/TP/Main switch including U/S MCBs/MCCB, isolators etc and making good disturbed surface complete all as specified and directed. |
| 129 | M&L for concealed point wiring with FRLSH PVC insulated unsheathed multistranded copper conductor cables 1100 Volts grade of 1.5 sqmm size alongwith one earth continuity conductor with FRLSH PVC insulated unsheathed multistranded copper conductor cable 1100 Volts grade of 1.5 sqmm size through and including 20mm dia (medium grade) rigid non metallic PVC concealed conduit terminated in and including pressed steel sunken boxes , readily available (Having wall thickness not less than 1.22 mm for boxes upto a size of 200 mmX300 mm and beyond that the wall thickness shall be not less than 1.63 mm) concealed type with 3mm thick bakelite sheet coverfor fixing of switches, sockets, fan regulators etc including testing on completion complete including cutting chases for concealed conduit pinning in making good to facing and pointing in using cement mortar 1:3 and making good to disturbed surface complete all as specified and directed for the followings: - |
| 130 | One light point/ Bell/ one fan point controlled by one switch |
| 131 | One 3 pin socket outlet, 6 Amp on the same board with other switches |
| 132 | One 3 pin socket outlet, 6 Amp independent |
| 133 | One light point controlled by two, two way switch 5 Amp |
| 134 | M&L for concealed point wiring with FRLSH PVC insulated unsheathed multistranded copper conductor cables 1100 Volts grade of 2.5 sqmm size alongwith one earth continuity conductor with FRLSH PVC insulated unsheathed multistranded copper conductor cable 1100 Volts grade of 2.5 sqmm size through and including 20 mm dia (medium grade) rigid non metallic PVC concealed conduit terminated in and including pressed steel sunken boxes , readily available (Having wall thickness not less than 1.22 mm for boxes upto a size of 200 mmX300 mm and beyond that the wall thickness shall be not less than 1.63 mm) concealed type with 3mm thick bakelite sheet coverfor fixing of switches, sockets, fan regulators etc including testing on completion complete including cutting chases for concealed conduit pinning in making good to facing and pointing in using cement mortar 1:3 and making good to disturbed surface complete all as specified and directed. |
| 135 | S&FModular switch 1 way 6A, 1 modulecomplete all as per specified and directed. |
| 136 | S&FModular switch 2 way 6A, 1 modulecomplete all as per specified and directed. |
| 137 | S&FModular switch 1 way 16A, 1 modulecomplete all as per specified and directed. |
| 138 | S&FModular Bell push 6A 1 module,complete all as per specified and directed. |
| 139 | S&F Socket,6A - 2/3 pin combined 2 module,complete all as per specified and directed. |
| 140 | S&F Socket6A/16A - 2/3 pin combined2 module,complete all as per specified and directed. |
| 141 | S&F modularFan step regulator, 120W - 2 modulecomplete all as per specified and directed. |
| 142 | S&F call bell ding dong 230V single pole complete all as per specified and directed. |
| 143 | S&F plug top 15 Amp PVC/corbonate type suitable for 15 Amps socket complete all as per specified and directed. |
| 144 | S&F Single Pole and neutral enclosure with a two pin and earth plug and socket complete with one single poleMCB 20Ampcomplete all as specified and directed. Make ABB/Legrand/Scheinder |
| 145 | S&F Sheet metal enclosure powder coatedfor MCB DB double door single pole & Neutral 4 way with 200Amp ratedcommon bus bar at incomming complete all as specified and directed.Make:- Legrand/havells/L&T/ABB. |
| 146 | S&F Sheet metal enclosure powder coatedfor MCB DB double door single pole & Neutral 8 way with 200Amp ratedcommon bus bar at incomming complete all as specified and directed.Make:- Legrand/havells/L&T/ABB. |
| 147 | S&F Sheet metal enclosure for MCB DB double door 240Vsingle pole & Neutral 12 way with common bus bar at incomming end complete all as specified and directed. |
| 148 | S&F Ceiling rose, 3 terminals PVC/polycarbonate, isolated body complete all as per specified and directed. |
| 149 | M&L for Earthing complete with galvanised steel earth plate electrode 60×60cm.× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less\"than 1.5 metres below normal ground level, connected to galvanised earth lead wire 4.0mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 of MES SSR Part-I connected to earthing test point all as specified or indicatedincluding testing on completion complete all as specified and directed. |
| 150 | Taking down ceiling fan of any sweep, keeping with safe custody and depositing to MES store yard complete all as specified and as directed. |
| 151 | M&L for sub main wiring with 2 run of FRLSH PVC insulated & unsheathed multistranded copper conductor of nominal cross sectional area 2.5 sqmm alongwith one run of FRLSH PVC insulated & unsheathed multistranded copper conductor of nominal cross sectional area 2.5 sqmm as earth continuity conductor drawn through and including PVC conduit not less than 20 mm dia complete all as specified and directed.Note: For concealed sub-main wiring cutting chases will be included in quoted rate. |
| 152 | M&L for sub main wiring with 2 run of FRLSH PVC insulated & unsheathed multistranded copper conductor of nominal cross sectional area 4.0 sqmm alongwith one run of FRLSH PVC insulated & unsheathed multistranded copper conductor of nominal cross sectional area 4.0 sqmm as earth continuity conductor drawn through and including PVC conduit not less than 20 mm dia complete all as specified and directed.Note: For concealed sub-main wiring cutting chases will be included in quoted rate. |
| 153 | M&L for sub main wiring with 2 run of FRLSH PVC insulated & unsheathed multistranded copper conductor of nominal cross sectional area 6.0 sqmm alongwith one run of FRLSH PVC insulated & unsheathed multistranded copper conductor of nominal cross sectional area 6.0 sqmm as earth continuity conductor drawn through and including PVC conduit 25mm complete all as specified and directed.Note: For concealed sub-main wiring cutting chases will be included in quoted rate. |
| 154 | Supply and fixing 240V, 10KA \"C\" curve single pole miniature circuit breaker (MCB) 6 to 32 Amps,in the MCB DB complete with connection testing and commissioning. complete all as specified and directed. |
| 155 | Supply and fixing240V, 10KA \"C\" curve SPN miniature circuit breaker (MCB) 40 to 63 Amps,in the MCB DB complete with connection testing and commissioning. complete all as specified and directed. |
| 156 | S&FDecorative wall mounted lumaineries made of metal with nickel finish wall lamp with opal glasssuitable B22 base type LED bulb 10Wcomplete with all accessories internally pre-wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size complete all as specified and directed. Make- Crompton Cat No WALLGLOW-C=B22 or equivalent of make specified. |
| 157 | Supply and fixing energy saving 100% copper wound ceiling fans complete with blades, down rods, electronic regulator and accessories, 230V,1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC) complete all as specified and directed. Make: Usha/Bajaj/HAVELLS |
| 158 | Supply and fixing LED tube light batten box type made of CRCA sheet with decorative end caps suitable with ultra bright glass LED tube light 1x 18/20 watt T8 type single side connection complete with both end bi-pin holder and all accessories internally prewired and fixed to wall/ceiling incl fittings accessories and connecting up with twin core flexible copper conductor cable suitable size complete all as specified and directed. |
| 159 | S&F energy saving new generation 10 watt LED bulk head fitting made of aluminium die cast housing IP 65 luminaries with opal diffuser prewired with warranty option of 5 years from date of installation and necessarymounting arrangements, provision of new 3 core multistranded copper conductor of size 23/0.193 from ceiling rose to fitting including LED bulbcomplete all as specified and directed. |
| 160 | S & F for Energy saving new generation environmental friendly long life versatile presure die cast aluminium IP 66 for security light fitting luminaire with high power LEDs as light source and electronic driver of capacity 25 watts with pre wired and necessary mounitng arrangements and provision of 1.5 sq mm three core copper dia GI pipe medium grade bracket 1.5 mtr long bend to required shape with clamps, nut, bolts complete all as directed. |
| 161 | S & F for energey efficient exhaust fan of 250mm sweep made of metal body ventil Air-DS type complete with louver with bolts nuts and washers size of the bolt 15 cm long 12mm dia embedded in the wall including provision of PVC flexible copper cable of size 23/0.0076 two core from ceiling rose to exhaust fan for connection and making suitable size of hole to existing brick wall for fan base complete all as directed by GE. |
| 162 | S & F for energey efficient exhaust fan of 300mm sweep made of metal body ventil Air-DS type complete with louver with bolts nuts and washers size of the bolt 15 cm long 12mm dia embedded in the wall including provision of PVC flexible copper cable of size 23/0.0076 two core from ceiling rose to exhaust fan for connection and making suitable size of hole to existing brick wall for fan base complete all as directed by GE. |
| 163 | S & F GI pipe medium grade with all fittings 50 mm dia fixed to wall for hanging of ceiling fan complete all as specified and directed. |
| 164 | S & F for wall mounted LED tube light fitting 10 watts batten for surface mounted, anodized extruded aluminium housing, high transmissitivity diffuser, high lumen ouput box type fitting, 230 volts and intregrated electronic driver connector block etc complete with all accessories internally pre wired and necessary mounting arrangements, provision of new 3 core multistranded copper conductor of size 23/0.193 from ceiling rose to fitting complete all as specified and directed. |
| 165 | Taking down of old sub main wiring any size and any type including batten/ conduit/ casing at any indicated situation complete all as specified and directed. |
| 166 | S&F electric water heater (Geyser),vertical storage type, 230 V, 50 Hz, stainless steelinner tank,heating element copper with nickle coated 2 KW, 8 bar pressure, capacity 25 litre, BEE 5 Star ratedthermostate (capaliary tube),thermal cutout, Multifunctional valve ( NRV/PRV/Drain), Dry heat protection, Weather proof IP-X4, Heavy duty magnesium anode, High grade ABS material outer body, High Density Puf for high energy efficiency, stainless steel connection pipe etc complete with all accessories withWarranty 2 Year for Geyser, 7 Years for Inner tank and 3 Years for Heating Element. including taking down unserviceable one and deposited to MES Yard complete all as specified and directed. Make :-USHA/ Bajaj/Havells |
| 167 | Supply, installation, commissioning and testing LT wall mounting Panel Board of minimum size 1.00 m (height) x 1.00 m (breath) x 0.30 (depth) factory made CPRI approved panel, weather, dust & vermin proof indoor, double door, frot openable and providing rubber/PVC gasket of suitable size all sides of door, with copper busbar wrapped with PVC tape/sleeves with maintained the colour code and copper strip/wire busbar of suitable size to MCCB input and MCCB/MCB output of suitable length for connection of cable from main busbar, made out of 2.00 mm thick mild steel CRCA sheet with suitable size angle iron supporting frame incuding applying two coats of Powder coated paint over a coat of red oxide zinc chrome primer over exposed external & internal surfaces suitable for 3 phase 4 wire system 415/440 volts grade including complete internal wiring with 1.5 sqmm copper wire and conncetions of all outgoing/ incoming existing cable of any size complete all as directed by Engineer-in-Charge. |
| 168 | Incoming:(a) Copper strip busbar of size 25 x 5 mm wrapped with PVC sleeves with maintained the colour code and provision of making holes with Copper nuts, bolts & washers for cable connections including hydrographic insulators with nuts & bolts at both ends = 04 nos.(b) MCCB IP 44 and IP 66/67 protection, 4 pole, 415 volts, Lcu=25 KA breaking capacity, rating 63 Amps, adjustable thermal magnetic release including all fixing accessories with both ends spreader links - 01 Nos.(c) Digital voltmeter of range (0-500) volts, flush mounting type of size 100mm x 100mm (4\"\"x4\"\") square dial with selector switch - 01 Nos.(d) LED Neon indicator lamp (RYB) with holder, 230/250 volts, AC-01 set (set of three) |
| 169 | Out going:-(a) MCB, Single pole & neutral, 32 amps, 240 volts, \"C\" curve, 10 KA all complete as specified and as directed - 08 Nos (One no meter input and one no for Accn output).(b) MCB, Single pole 6 amps, 240 volts, \"C\" Curve, 10 KA all complete as specified and as directed - 02 Nos (Stair Case lighting)(c) Refixing of old electric meter - 04 Nos. |
| 170 | S&F 36W LED Square Type, 2\" x2\" recessed mounted downlighter,White powder coated CRCA housing, high translucent frosted diffuser, efficacy>100Lm/Watt,high performance electronic integraldriver, THD<10%, PF>0.95 (Warm white/Natural White Colour) & all accessories etc for fixing arrangement complete all as specified & directed. |
| 171 | (Note : The Scope of Work contained in \"Sch of Credit\" amounting to Rs. 90,891.00. The Quoted sum shall be arrived at after deducting the amount of “Sch of Credit” from the total amount of the ‘BoQ’ |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail